1
|
Dielectric Elastomer Actuator-Based Valveless Impedance-Driven Pumping for Meso- and Macroscale Applications. Soft Robot 2024; 11:198-206. [PMID: 37729065 DOI: 10.1089/soro.2022.0244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2023] Open
Abstract
Impedance pumps are simple designs that allow the generation or amplification of flow. They are fluid-filled systems based on flexible tubing connected to tubing with different impedances. A periodic off-center compression of the flexible tubing causes the fluid to move and generate flow. Wave reflection at the impedance mismatch is the primary driving mechanism of the flow. In addition to their straightforward design, impedance pumps are bladeless, valveless, and pulsatile. These properties are highly sought after by demanding and challenging applications, such as the biomedical field, as they present less risk of damage, disruption, and obstruction when handling viscous and delicate fluids/matter. In this study, we propose a high-performance impedance-driven pumping concept with embedded actuation based on a multilayered tubular dielectric elastomer. This pumping system is made of three parts, a dielectric elastomer actuator tube, a passive tube, and a rigid ring that binds and decouples the two subsystems. The system is able to generate net fluid flow rates up to 1.35 L/min with an internal pressure of 125 mmHg. The soft simplistic design, self-contained concept, and high performances of these pumping systems could make them disruptive in many challenging meso- and macroscale applications in general and in the biomedical field in particular.
Collapse
|
2
|
Dielectric elastomer actuator-based valveless pump as Fontan failure assist device: introduction and preliminary study. INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY 2024; 38:ivae041. [PMID: 38514398 PMCID: PMC11001492 DOI: 10.1093/icvts/ivae041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 02/07/2024] [Accepted: 03/19/2024] [Indexed: 03/23/2024]
Abstract
OBJECTIVES Fontan failure refers to a condition in which the Fontan circulation, a surgical procedure used to treat certain congenital heart defects, becomes insufficient, leading to compromised cardiac function and potential complications. This in vitro study therefore investigates the feasibility of bladeless impedance-driven cavopulmonary assist device via dielectric elastomer actuator (DEA) as a means to address Fontan failure. METHODS A cavopulmonary assist device, constructed using DEA technologies and employing the impedance pump concept, is subjected to in vitro testing within a closed-loop setup. This study aims to assess the device's functionality and performance under controlled conditions, providing valuable insights into its potential application as a cavopulmonary assistive technology. RESULTS The DEA-based pump, measuring 50 mm in length and 30 mm in diameter, is capable of achieving substantial flow rates within a closed-loop setup, reaching up to 1.20 l/min at an activation frequency of 4 Hz. It also provides a broad range of working internal pressures (<10 to >20 mmHg). Lastly, the properties of the flow (direction, magnitude, etc.) can be controlled by adjusting the input signal parameters (frequency, amplitude, etc.). CONCLUSIONS In summary, the results suggest that the valveless impedance-driven pump utilizing DEA technology is promising in the context of cavopulmonary assist devices. Further research and development in this area may lead to innovative and potentially more effective solutions for assisting the right heart, ultimately benefiting patients with heart-related health issues overall, with a particular focus on those experiencing Fontan failure.
Collapse
|
3
|
Novel para-aortic cardiac assistance using a pre-stretched dielectric elastomer actuator. INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY 2024; 38:ivae027. [PMID: 38419585 PMCID: PMC10955250 DOI: 10.1093/icvts/ivae027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 02/07/2024] [Accepted: 02/26/2024] [Indexed: 03/02/2024]
Abstract
OBJECTIVES We propose an evolution of a dielectric elastomer actuator-based cardiac assist device that acts as a counterpulsation system. We introduce a new pre-stretched actuator and implant the device in a graft bypass between the ascending and descending aorta to redirect all blood through the device (ascending aorta clamped). The objective was to evaluate the influence of these changes on the assistance provided to the heart. METHODS The novel para-aortic device and the new implantation technique were tested in vivo in 5 pigs. We monitored the pressure and flow in the aorta as well as the pressure-volume characteristics of the left ventricle. Different activation timings were tested to identify the optimal device actuation. RESULTS The proposed device helps reducing the end-diastolic pressure in the aorta by up to 13 ± 4.0% as well as the peak systolic pressure by up to 16 ± 3.6%. The early diastolic pressure was also increased up to 10 ± 3.5%. With different activation, we also showed that the device could increase or decrease the stroke volume. CONCLUSIONS The new setup and the novel para-aortic device presented here helped improve cardiac assistance compared to previous studies. Moreover, we revealed a new way to assist the heart by actuating the device at different starting time to modify the left ventricular stroke volume and stroke work.
Collapse
|
4
|
Is the time right for a new initiative in mathematical modeling of the lower urinary tract? ICI-RS 2023. Neurourol Urodyn 2023. [PMID: 38149773 DOI: 10.1002/nau.25362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 12/01/2023] [Indexed: 12/28/2023]
Abstract
INTRODUCTION A session at the 2023 International Consultation on Incontinence - Research Society (ICI-RS) held in Bristol, UK, focused on the question: Is the time right for a new initiative in mathematical modeling of the lower urinary tract (LUT)? The LUT is a complex system, comprising various synergetic components (i.e., bladder, urethra, neural control), each with its own dynamic functioning and high interindividual variability. This has led to a variety of different types of models for different purposes, each with advantages and disadvantages. METHODS When addressing the LUT, the modeling approach should be selected and sized according to the specific purpose, the targeted level of detail, and the available computational resources. Four areas were selected as examples to discuss: utility of nomograms in clinical use, value of fluid mechanical modeling, applications of models to simplify urodynamics, and utility of statistical models. RESULTS A brief literature review is provided along with discussion of the merits of different types of models for different applications. Remaining research questions are provided. CONCLUSIONS Inadequacies in current (outdated) models of the LUT as well as recent advances in computing power (e.g., quantum computing) and methods (e.g., artificial intelligence/machine learning), would dictate that the answer is an emphatic "Yes, the time is right for a new initiative in mathematical modeling of the LUT."
Collapse
|
5
|
Hemodynamic effects of a dielectric elastomer augmented aorta on aortic wave intensity: An in-vivo study. J Biomech 2023; 159:111777. [PMID: 37666100 DOI: 10.1016/j.jbiomech.2023.111777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 08/09/2023] [Accepted: 08/22/2023] [Indexed: 09/06/2023]
Abstract
Dielectric elastomer actuator augmented aorta (DEA) represents a novel approach with high potential for assisting a failing heart. The soft tubular device replaces a section of the aorta and increases its diameter when activated. The hemodynamic interaction between the DEA and the left ventricle (LV) has not been investigated with wave intensity (WI) analysis before. The objective of this study is to investigate the hemodynamic effects of the DEA on the aortic WI pattern. WI was calculated from aortic pressure and flow measured in-vivo in the descending aorta of two pigs implanted with DEAs. The DEAs were tested for different actuation phase shifts (PS). The DEA generated two decompression waves (traveling upstream and downstream of the device) at activation followed by two compression waves at deactivation. Depending on the PS, the end-diastolic pressure (EDP) decreased by 7% (or increased by 5-6%). The average early diastolic pressure augmentation (Pdia¯) increased by 2% (or decreased by 2-3%). The hydraulic work (WH) measured in the aorta decreased by 2% (or increased by 5%). The DEA-generated waves interfered with the LV-generated waves, and the timing of the waves affected the hemodynamic effect of the device. For the best actuation timing the upstream decompression wave arrived just before aortic valve opening and the upstream compression wave arrived just before aortic valve closure leading to a decreased EDP, an increased Pdia¯ and a reduced.WH.
Collapse
|
6
|
A novel soft cardiac assist device based on a dielectric elastomer augmented aorta: An in vivo study. Bioeng Transl Med 2023; 8:e10396. [PMID: 36925677 PMCID: PMC10013878 DOI: 10.1002/btm2.10396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 07/12/2022] [Accepted: 08/08/2022] [Indexed: 11/05/2022] Open
Abstract
Although heart transplant is the preferred solution for patients suffering from heart failures, cardiac assist devices remain key substitute therapies. Among them, aortic augmentation using dielectric elastomer actuators (DEAs) might be an alternative technological application for the future. The electrically driven actuator does not require bulky pneumatic elements (such as conventional intra-aortic balloon pumps) and conforms tightly to the aorta thanks to the manufacturing method presented here. In this study, the proposed DEA-based device replaces a section of the aorta and acts as a counterpulsation device. The feasibility and validation of in vivo implantation of the device into the descending aorta in a porcine model, and the level of support provided to the heart are investigated. Additionally, the influence of the activation profile and delay compared to the start of systole is studied. We demonstrate that an activation of the DEA just before the start of systole (30 ms at 100 bpm) and deactivation just after the start of diastole (0-30 ms) leads to an optimal assistance of the heart with a maximum energy provided by the DEA. The end-diastolic and left ventricular pressures were lowered by up to 5% and 1%, respectively, compared to baseline. The early diastolic pressure was augmented in average by up to 2%.
Collapse
|
7
|
Fluid mechanical performance of ureteral stents: The role of side hole and lumen size. Bioeng Transl Med 2023; 8:e10407. [PMID: 36925692 PMCID: PMC10013766 DOI: 10.1002/btm2.10407] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 07/22/2022] [Accepted: 08/16/2022] [Indexed: 01/05/2023] Open
Abstract
Ureteral stents are indispensable devices in urological practice to maintain and reinstate the drainage of urine in the upper urinary tract. Most ureteral stents feature openings in the stent wall, referred to as side holes (SHs), which are designed to facilitate urine flux in and out of the stent lumen. However, systematic discussions on the role of SH and stent lumen size in regulating flux and shear stress levels are still lacking. In this study, we leveraged both experimental and numerical methods, using microscopic-Particle Image Velocimetry and Computational Fluid Dynamic models, respectively, to explore the influence of varying SH and lumen diameters. Our results showed that by reducing the SH diameter from 1.1 to 0.4 mm the median wall shear stress levels of the SHs near the ureteropelvic junction and ureterovesical junction increased by over 150 % , even though the flux magnitudes through these SH decreased by about 40 % . All other SHs were associated with low flux and low shear stress levels. Reducing the stent lumen diameter significantly impeded the luminal flow and the flux through SHs. By means of zero-dimensional models and scaling relations, we summarized previous findings on the subject and argued that the design of stent inlet/outlet is key in regulating the flow characteristics described above. Finally, we offered some clinically relevant input in terms of choosing the right stent for the right patient.
Collapse
|
8
|
An in vitro bladder model with physiological dynamics: Vesicoureteral reflux alters stent encrustation pattern. Front Bioeng Biotechnol 2022; 10:1028325. [PMID: 36304894 PMCID: PMC9592728 DOI: 10.3389/fbioe.2022.1028325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 09/22/2022] [Indexed: 11/22/2022] Open
Abstract
In vitro models are indispensable to study the physio-mechanical characteristics of the urinary tract and to evaluate ureteral stent performances. Yet previous models mimicking the urinary bladder have been limited to static or complicated systems. In this study, we designed a simple in vitro bladder model to simulate the dynamics of filling and voiding. The physio-mechanical condition of the model was verified using a pressure-flow test with different bladder outlet obstruction levels, and a reflux test was performed to qualitatively demonstrate the stent associated vesicoureteral reflux (VUR). Finally, the setup was applied with and without the bladder model to perform encrustation tests with artificial urine on commercially available double-J stents, and the volumes of luminal encrustations were quantified using micro-Computed Tomography and image segmentation. Our results suggest that, VUR is an important factor contributing to the dynamics in the upper urinary tract with indwelling stents, especially in patients with higher bladder outlet obstruction levels. The influence of VUR should be properly addressed in future in vitro studies and clinical analyses.
Collapse
|
9
|
Effect of Collateral Flow on Catheter-Based Assessment of Cardiac Microvascular Obstruction. Ann Biomed Eng 2022; 50:1090-1102. [PMID: 35639221 PMCID: PMC9363345 DOI: 10.1007/s10439-022-02985-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Accepted: 05/17/2022] [Indexed: 11/28/2022]
Abstract
Cardiac microvascular obstruction (MVO) associated with acute myocardial infarction (heart attack) is characterized by partial or complete elimination of perfusion in the myocardial microcirculation. A new catheter-based method (CoFI, Controlled Flow Infusion) has recently been developed to diagnose MVO in the catheterization laboratory during acute therapy of the heart attack. A porcine MVO model demonstrates that CoFI can accurately identify the increased hydraulic resistance of the affected microvascular bed. A benchtop microcirculation model was developed and tuned to reproduce in vivo MVO characteristics. The tuned benchtop model was then used to systematically study the effect of different levels of collateral flow. These experiments showed that measurements obtained in the catheter-based method were adversely affected such that collateral flow may be misinterpreted as MVO. Based on further analysis of the measured data, concepts to mitigate the adverse effects were formulated which allow discrimination between collateral flow and MVO.
Collapse
|
10
|
Fluid mechanical modeling of the upper urinary tract. WIREs Mech Dis 2021; 13:e1523. [PMID: 34730288 DOI: 10.1002/wsbm.1523] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Revised: 02/01/2021] [Accepted: 02/02/2021] [Indexed: 12/20/2022]
Abstract
The upper urinary tract (UUT) consists of kidneys and ureters, and is an integral part of the human urogenital system. Yet malfunctioning and complications of the UUT can happen at all stages of life, attributed to reasons such as congenital anomalies, urinary tract infections, urolithiasis and urothelial cancers, all of which require urological interventions and significantly compromise patients' quality of life. Therefore, many models have been developed to address the relevant scientific and clinical challenges of the UUT. Of all approaches, fluid mechanical modeling serves a pivotal role and various methods have been employed to develop physiologically meaningful models. In this article, we provide an overview on the historical evolution of fluid mechanical models of UUT that utilize theoretical, computational, and experimental approaches. Descriptions of the physiological functionality of each component are also given and the mechanical characterizations associated with the UUT are provided. As such, it is our aim to offer a brief summary of the current knowledge of the subject, and provide a comprehensive introduction for engineers, scientists, and clinicians who are interested in the field of fluid mechanical modeling of UUT. This article is categorized under: Cancer > Biomedical Engineering Infectious Diseases > Biomedical Engineering Reproductive System Diseases > Biomedical Engineering.
Collapse
|
11
|
Potential strategies to prevent encrustations on urinary stents and catheters - thinking outside the box: a European network of multidisciplinary research to improve urinary stents (ENIUS) initiative. Expert Rev Med Devices 2021; 18:697-705. [PMID: 34085555 DOI: 10.1080/17434440.2021.1939010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Introduction: Urinary stents have been around for the last 4 decades, urinary catheters even longer. They are associated with infections, encrustation, migration, and patient discomfort. Research efforts to improve them have shifted onto molecular and cellular levels. ENIUS brought together translational scientists to improve urinary implants and reduce morbidity.Methods & materials: A working group within the ENIUS network was tasked with assessing future research lines for the improvement of urinary implants.Topics were researched systematically using Embase and PubMed databases. Clinicaltrials.gov was consulted for ongoing trials.Areas covered: Relevant topics were coatings with antibodies, enzymes, biomimetics, bioactive nano-coats, antisense molecules, and engineered tissue. Further, pH sensors, biodegradable metals, bactericidal bacteriophages, nonpathogenic uropathogens, enhanced ureteric peristalsis, electrical charges, and ultrasound to prevent stent encrustations were addressed.Expert opinion: All research lines addressed in this paper seem viable and promising. Some of them have been around for decades but are yet to proceed to clinical application (i.e. tissue engineering). Others are very recent and, at least in urology, still only conceptual (i.e. antisense molecules). Perhaps the most important learning point resulting from this pan-European multidisciplinary effort is that collaboration between all stakeholders is not only fruitful but also truly essential.
Collapse
|
12
|
Feasibility of a Dielectric Elastomer Augmented Aorta. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:2001974. [PMID: 33747718 PMCID: PMC7967089 DOI: 10.1002/advs.202001974] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 10/09/2020] [Indexed: 06/12/2023]
Abstract
Although heart transplantation is a gold standard for severe heart failure, there is a need for alternative effective therapies. A dielectric-elastomer aorta is used to augment the physiological role of the aorta in the human circulatory system. To this end, the authors developed a tubular dielectric elastomer actuator (DEA) able to assist the heart by easing the deformation of the aorta in the systole and by increasing its recoil force in the diastole. In vitro experiments using a pulsatile flow-loop, replicating human physiological flow and pressure conditions, show a reduction of 5.5% (47 mJ per cycle) of the heart energy with this device. Here, the controlled stiffness of the DEA graft, which is usually difficult to exploit for actuators, is perfectly matching the assistance principle. At the same time, the physiological aortic pressure is exploited to offer a prestretch to the DEA which otherwise would require an additional bulky pre-stretching system to reach high performances.
Collapse
|
13
|
Local vs. Global Blood Flow Modulation in Artificial Microvascular Networks: Effects on Red Blood Cell Distribution and Partitioning. Front Physiol 2020; 11:566273. [PMID: 33123027 PMCID: PMC7571285 DOI: 10.3389/fphys.2020.566273] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Accepted: 08/12/2020] [Indexed: 12/12/2022] Open
Abstract
Our understanding of cerebral blood flow (CBF) regulation during functional activation is still limited. Alongside with the accepted role of smooth muscle cells in controlling the arteriolar diameter, a new hypothesis has been recently formulated suggesting that CBF may be modulated by capillary diameter changes mediated by pericytes. In this study, we developed in vitro microvascular network models featuring a valve enabling the dilation of a specific micro-channel. This allowed us to investigate the non-uniform red blood cell (RBC) partitioning at microvascular bifurcations (phase separation) and the hematocrit distribution at rest and for two scenarios modeling capillary and arteriolar dilation. RBC partitioning showed similar phase separation behavior during baseline and activation. Results indicated that the RBCs at diverging bifurcations generally enter the high-flow branch (classical partitioning). Inverse behavior (reverse partitioning) was observed for skewed hematocrit profiles in the parent vessel of bifurcations, especially for high RBC velocity (i.e., arteriolar activation). Moreover, results revealed that a local capillary dilation, as it may be mediated in vivo by pericytes, led to a localized increase of RBC flow and a heterogeneous hematocrit redistribution within the whole network. In case of a global increase of the blood flow, as it may be achieved by dilating an arteriole, a homogeneous increase of RBC flow was observed in the whole network and the RBCs were concentrated along preferential pathways. In conclusion, overall increase of RBC flow could be obtained by arteriolar and capillary dilation, but only capillary dilation was found to alter the perfusion locally and heterogeneously.
Collapse
|
14
|
In vitro investigations of red blood cell phase separation in a complex microchannel network. BIOMICROFLUIDICS 2020; 14:014101. [PMID: 31933711 PMCID: PMC6941945 DOI: 10.1063/1.5127840] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Accepted: 12/14/2019] [Indexed: 06/10/2023]
Abstract
Microvascular networks feature a complex topology with multiple bifurcating vessels. Nonuniform partitioning (phase separation) of red blood cells (RBCs) occurs at diverging bifurcations, leading to a heterogeneous RBC distribution that ultimately affects the oxygen delivery to living tissues. Our understanding of the mechanisms governing RBC heterogeneity is still limited, especially in large networks where the RBC dynamics can be nonintuitive. In this study, our quantitative data for phase separation were obtained in a complex in vitro network with symmetric bifurcations and 176 microchannels. Our experiments showed that the hematocrit is heterogeneously distributed and confirmed the classical result that the branch with a higher blood fraction received an even higher RBC fraction (classical partitioning). An inversion of this classical phase separation (reverse partitioning) was observed in the case of a skewed hematocrit profile in the parent vessels of bifurcations. In agreement with a recent computational study [P. Balogh and P. Bagchi, Phys. Fluids 30,051902 (2018)], a correlation between the RBC reverse partitioning and the skewness of the hematocrit profile due to sequential converging and diverging bifurcations was reported. A flow threshold below which no RBCs enter a branch was identified. These results highlight the importance of considering the RBC flow history and the local RBC distribution to correctly describe the RBC phase separation in complex networks.
Collapse
|
15
|
Modulation of Bladder Wall Micromotions Alters Intravesical Pressure Activity in the Isolated Bladder. Front Physiol 2019; 9:1937. [PMID: 30687132 PMCID: PMC6335571 DOI: 10.3389/fphys.2018.01937] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Accepted: 12/21/2018] [Indexed: 12/20/2022] Open
Abstract
Micromotions are phasic contractions of the bladder wall. During urine storage, such phasic activity has little effect on intravesical pressure, however, changed motile activity may underlie urodynamic observations such as detrusor overactivity. The potential for bladder motility to affect pressure reflects a summation of the overall movements, comprising the initiation, propagation, and dissipation components of micromotions. In this study, the influence of initiation of micromotions was investigated using calcium activated chloride channel blocker niflumic acid, and the effect of propagation using blockers of gap junctions. The overall bladder tone was modulated using isoprenaline. Isolated tissue strips and whole bladder preparations from juvenile rats were used. 18β-glycyrrhetinic acid was used to block gap junctions, reducing the amplitude and frequency of micromotions in in vitro and ex vivo preparations. Niflumic acid reduced the frequency of micromotions but had no effect on the amplitude of pressure fluctuations. Isoprenaline resulted in a reduction in pressure fluctuations and a decrease in pressure baseline. Using visual video data analysis, bladder movement was visible, irrespective of lack of pressure changes, which persisted during bladder relaxation. However, micromotions propagated over shorter distances and the overall bladder tone was reduced. All these results suggest that phasic activity of the bladder can be characterised by a combination of initiation and propagation of movement, and overall bladder tone. At any given moment, intravesical pressure recordings are an integration of these parameters. This synthesis gives insight into the limitations of clinical urodynamics, where intravesical pressure is the key indicator of detrusor activity.
Collapse
|
16
|
Cardiac electrophysiology catheters for electrophysiological assessments of the lower urinary tract-A proof of concept ex vivo study in viable ureters. Neurourol Urodyn 2018; 38:87-96. [DOI: 10.1002/nau.23816] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2018] [Accepted: 08/16/2018] [Indexed: 12/30/2022]
|
17
|
Detection and quantification of overactive bladder activity in patients: Can we make it better and automatic? Neurourol Urodyn 2017; 37:823-831. [DOI: 10.1002/nau.23357] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2017] [Accepted: 06/19/2017] [Indexed: 12/21/2022]
|
18
|
A novel single compartment in vitro model for electrophysiological research using the perfluorocarbon FC-770. Physiol Res 2017; 65:341-8. [PMID: 27322010 DOI: 10.33549/physiolres.933099] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Electrophysiological studies of whole organ systems in vitro often require measurement of nerve activity and/or stimulation of the organ via the associated nerves. Currently two-compartment setups are used for such studies. These setups are complicated and require two fluids in two separate compartments and stretching the nerve across one chamber to the other, which may damage the nerves. We aimed at developing a simple single compartment setup by testing the electrophysiological properties of FC-770 (a perfluorocarbon) for in vitro recording of bladder afferent nerve activity and electrical stimulation of the bladder. Perflurocarbons are especially suitable for such a setup because of their high oxygen carrying capacity and insulating properties. In male Wistar rats, afferent nerve activity was recorded from postganglionic branches of the pelvic nerve in vitro, in situ and in vivo. The bladder was stimulated electrically via the efferent nerves. Organ viability was monitored by recording spontaneous contractions of the bladder. Additionally, histological examinations were done to test the effect of FC-770 on the bladder tissue. Afferent nerve activity was successfully recorded in a total of 11 rats. The bladders were stimulated electrically and high amplitude contractions were evoked. Histological examinations and monitoring of spontaneous contractions showed that FC-770 maintained organ viability and did not cause damage to the tissue. We have shown that FC-770 enables a simple, one compartment in vitro alternative for the generally used two compartment setups for whole organ electrophysiological studies.
Collapse
|
19
|
Abstract
Urethane is a widely used anesthetic in animal lower urinary tract research. Our objective was to investigate the quality of anesthesia and the correlation between bladder (voiding) contractions, micturition pressure, bladder capacity and urethane dosage and body weight. Urethane was given subcutaneously and/or intraperitoneally (1.0-1.2 g/kg). The bladder was filled with saline and the bladder pressure was recorded continuously. Animals in which the subcutaneous/intraperitoneal ratio was higher needed less urethane. Heavier animals needed less extra urethane. In animals, in which no bladder contractions could be evoked, the total amount of urethane given was similar to that in those that did show contractions. In the animals that did void, the bladder never emptied completely and residual volumes remained. There was no relationship between animal weight or total amount of urethane and mean capacity. Anesthesia lasted up till 14 h, during which bladder (voiding) contractions could be recorded. Considering all results, we conclude that urethane is a well suited anesthetic for acute lower urinary tract physiological research in the intact rat.
Collapse
|
20
|
Neurophysiological modeling of bladder afferent activity in the rat overactive bladder model. J Physiol Sci 2015; 65:329-38. [PMID: 25782438 PMCID: PMC4477068 DOI: 10.1007/s12576-015-0370-y] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2014] [Accepted: 02/21/2015] [Indexed: 11/06/2022]
Abstract
The overactive bladder (OAB) is a syndrome-based urinary dysfunction characterized by “urgency, with or without urge incontinence, usually with frequency and nocturia”. Earlier we developed a mathematical model of bladder nerve activity during voiding in anesthetized rats and found that the nerve activity in the relaxation phase of voiding contractions was all afferent. In the present study, we applied this mathematical model to an acetic acid (AA) rat model of bladder overactivity to study the sensitivity of afferent fibers in intact nerves to bladder pressure and volume changes. The afferent activity in the filling phase and the slope, i.e., the sensitivity of the afferent fibers to pressure changes in the post-void relaxation phase, were found to be significantly higher in AA than in saline measurements, while the offset (nerve activity at pressure ~0) and maximum pressure were comparable. We have thus shown, for the first time, that the sensitivity of afferent fibers in the OAB can be studied without cutting nerves or preparation of single fibers. We conclude that bladder overactivity induced by AA in rats is neurogenic in origin and is caused by increased sensitivity of afferent sensors in the bladder wall.
Collapse
|
21
|
Wave intensity analysis in air-filled flexible vessels. J Biomech 2014; 48:687-694. [PMID: 25595424 DOI: 10.1016/j.jbiomech.2014.12.037] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2014] [Revised: 12/11/2014] [Accepted: 12/12/2014] [Indexed: 10/24/2022]
Abstract
Wave intensity analysis (WIA) is an analytical technique generally used to investigate the propagation of waves in the cardiovascular system. Despite its increasing usage in the cardiovascular system, to our knowledge WIA has never been applied to the respiratory system. Given the analogies between arteries and airways (i.e. fluid flow in flexible vessels), the aim of this work is to test the applicability of WIA with gas flow instead of liquid flow. The models employed in this study are similar to earlier studies used for arterial investigations. Simultaneous pressure (P) and velocity (U) measurements were initially made in a single tube and then in several flexible tubes connected in series. Wave speed was calculated using the foot-to-foot method (cf), which was used to separate analytically the measured P and U waveforms into their forward and backward components. Further, the data were used to calculate wave intensity, which was also separated into its forward and backward components. Although the measured wave speed was relatively high, the results showed that the onsets and the nature of reflections (compression/expansion) derived with WIA, corresponded well to those anticipated using the theory of waves in liquid-filled elastic tubes. On average the difference between the experimental and theoretical arrival time of reflection was 6.1% and 3.6% for the single vessel and multivessel experiment, respectively. The results suggest that WIA can provide relatively accurate information on reflections in air-filled flexible tubes, warranting further studies to explore the full potential of this technique in the respiratory system.
Collapse
|
22
|
Frequency analysis of urinary bladder pre-voiding activity in normal and overactive rat detrusor. Neurourol Urodyn 2014; 34:794-9. [DOI: 10.1002/nau.22664] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2014] [Accepted: 07/07/2014] [Indexed: 12/30/2022]
|
23
|
Investigating the flow dynamics in the obstructed and stented ureter by means of a biomimetic artificial model. PLoS One 2014; 9:e87433. [PMID: 24498322 PMCID: PMC3911952 DOI: 10.1371/journal.pone.0087433] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2013] [Accepted: 12/23/2013] [Indexed: 12/02/2022] Open
Abstract
Double-J stenting is the most common clinical method employed to restore the upper urinary tract drainage, in the presence of a ureteric obstruction. After implant, stents provide an immediate pain relief by decreasing the pressure in the renal pelvis (P). However, their long-term usage can cause infections and encrustations, due to bacterial colonization and crystal deposition on the stent surface, respectively. The performance of double-J stents - and in general of all ureteric stents - is thought to depend significantly on urine flow field within the stented ureter. However very little fundamental research about the role played by fluid dynamic parameters on stent functionality has been conducted so far. These parameters are often difficult to assess in-vivo, requiring the implementation of laborious and expensive experimental protocols. The aim of the present work was therefore to develop an artificial model of the ureter (i.e. ureter model, UM) to mimic the fluid dynamic environment in a stented ureter. The UM was designed to reflect the geometry of pig ureters, and to investigate the values of fluid dynamic viscosity (μ), volumetric flow rate (Q) and severity of ureteric obstruction (OB%) which may cause critical pressures in the renal pelvis. The distributed obstruction derived by the sole stent insertion was also quantified. In addition, flow visualisation experiments and computational simulations were performed in order to further characterise the flow field in the UM. Unique characteristics of the flow dynamics in the obstructed and stented ureter have been revealed with using the developed UM.
Collapse
|
24
|
Can an algorithm predict a voiding contraction in unconscious rats? ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2013:1334-7. [PMID: 24109942 DOI: 10.1109/embc.2013.6609755] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Urinary incontinence (UI) is a very common and serious disorder which can be classified in stress and urge incontinence, the latter mainly caused by an overactive bladder (OAB). A definitive treatment for OAB does not exist yet due to its complex nature. Therefore, more attention must be focused on improving the patient's quality of life. A device able to alert the patient to development of a voiding contraction would be highly desirable, enabling actions to avoid incontinence. The main hypothesis of this work is that a voiding contraction is preceded by a consistent change in the pattern of intravesical pressure (p(ves)). We developed an algorithm based on frequency analysis of p(ves) recordings of two strains of rats whose bladders were first filled with saline (S fillings) and then with acetic acid (AA fillings); the latter was used as model for OAB in rats. The algorithm was designed to provide an alarm when an increase in the range 0.2-0.6 Hz of the amplitude spectrum was detected. The accuracy of the algorithm has been tested and quantified, successful alarms were those taking place within fifty seconds before the start of voiding. Although the results are still very preliminary, due to the low number of tested animals, they seem encouraging since, in five rats, only one showed a percentage of success lower than 50%, with one rat reaching 100%. The accuracy of the algorithm is affected by the choice of the values for the controlling parameters, which have been set the same for all rats; future developments might include individual values for each rat.
Collapse
|
25
|
An artificial model for studying fluid dynamics in the obstructed and stented ureter. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2013:5335-8. [PMID: 24110941 DOI: 10.1109/embc.2013.6610754] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Fluid dynamics in the obstructed and stented ureter represents a non-trivial subject of investigation since, after stent placement, the urine can flow either through the stent lumen or in the extra-luminal space located between the stent wall and the ureteric inner wall. Fluid dynamic investigations can help understanding the phenomena behind stent failure (e.g. stent occlusions due to bacterial colonization and encrustations), which may cause kidney damage due to the associated high pressures generated in the renal pelvis. In this work a microfluidic-based transparent device (ureter model, UM) has been developed to simulate the fluid dynamic environment in a stented ureter. UM geometry has been designed from measurements on pig ureters. Pressure in the renal pelvis compartment has been measured against three variables: fluid viscosity (μ), volumetric flow rate (Q) and level of obstruction (OB%). The measurements allowed a quantification of the critical combination of μ, Q and OB% values which may lead to critical pressure levels in the kidney. Moreover, an example showing the possibility of applying particle image velocimetry (PIV) technology to the developed microfluidic device is provided.
Collapse
|
26
|
A novel single compartment in vitro model: Perflurocarbons for electrophysiological studies of the rat urinary bladder. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2013:1446-1449. [PMID: 24109970 DOI: 10.1109/embc.2013.6609783] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This study presents a novel single compartment model for in vitro electrophysiological studies of the rat urinary bladder. We tested the functionality and suitability of FC-770 (a Perflurocarbon) for in vitro recording of nerve activity arising from the bladder in a single compartment setup. We have also favorably tested stimulation of the bladder via the bladder nerves in FC-770. The organ viability was monitored by recording spontaneous contractions of the bladder for a certain time. We propose the use of FC-770 as a fluid for nerve recording/stimulation in vitro as well as for maintaining organ viability, over the commonly used two compartmental methods.
Collapse
|
27
|
One-dimensional modelling of pulse wave propagation in human airway bifurcations in space-time variables. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2010; 2009:5482-5. [PMID: 19965046 DOI: 10.1109/iembs.2009.5334564] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Airflow in the respiratory system is complicated as it goes through various regions with different geometries and mechanical properties. Three-dimensional (3-D) simulations are typically limited to local areas of the system because of their high computational cost. On the other hand, the one-dimensional (1-D) equations of flow in compliant tubes offer a good compromise between accuracy and computational cost when a global assessment of airflow in the system is required. The aim of the current study is to apply the 1-D formulation in space and time variables to study the propagation of a pulse wave in human airways; first in a simple system composed of just one bifurcation, trachea-main bronchi, according to the symmetrical Weibel model. Then extending the system to include a further generation, the bronchi branches. Pulse waveforms carry information about the functionality and morphology of the respiratory system and the 1-D modelling, in terms of space and time variables, represents an innovative approach for respiratory response interpretation. 1-D modelling in space-time variables has been extensively applied to simulate blood pressure and flow in the cardiovascular system. This work represents the first attempt to apply this formulation to study pulse waveforms in the human bronchial tree.
Collapse
|
28
|
One-dimensional computational model of pulse wave propagation in the human bronchial tree. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2010; 2010:2473-2476. [PMID: 21096163 DOI: 10.1109/iembs.2010.5626559] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Airflow in the respiratory system has been predominantly studied in rigid ducts. Three-dimensional simulations are computationally expensive. One-dimensional (1-D) modelling offers a good compromise between accuracy and computational cost. In this work we described the propagation of air pulse in a model of human airways using the 1-D equations of flow in compliant vessels. Seven generations of bifurcations, starting from the trachea, were studied. Peripheral airways (from the 8(th) to 23(rd) generation) were modelled using lumped parameter models. Peripheral resistance values for normal and emphysematous lungs were taken from the literature. An acceleration pulse, very short in time, was enforced at the inlet of trachea. The results suggest that compression (positive pressure peaks) and expansion (negative pressure peaks) waves are generated according to the reflection coefficients of the corresponding reflection sites (bifurcations and terminal reflections). Different values for peripheral bronchial resistance generate three different terminal reflections, all negative with different wave amplitudes. The sensitivity of the code to different peripheral resistances suggests that the 1-D formulation is a promising tool for a better understanding of the impact of disease on the velocity and pressure waveforms in the first generations of airway vessels.
Collapse
|