1
|
Adjudicated myocarditis and multisystem illness trajectory in healthcare workers post-COVID-19. Open Heart 2023; 10:openhrt-2022-002192. [PMID: 36822817 PMCID: PMC9950584 DOI: 10.1136/openhrt-2022-002192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Accepted: 01/27/2023] [Indexed: 02/25/2023] Open
Abstract
BACKGROUND We investigated the associations of healthcare worker status with multisystem illness trajectory in hospitalised post-COVID-19 individuals. METHODS AND RESULTS One hundred and sixty-eight patients were evaluated 28-60 days after the last episode of hospital care. Thirty-six (21%) were healthcare workers. Compared with non-healthcare workers, healthcare workers were of similar age (51.3 (8.7) years vs 55.0 (12.4) years; p=0.09) more often women (26 (72%) vs 48 (38%); p<0.01) and had lower 10-year cardiovascular risk (%) (8.1 (7.9) vs 15.0 (11.5); p<0.01) and Coronavirus Clinical Characterisation Consortium in-hospital mortality risk (7.3 (10.2) vs 12.7 (9.8); p<0.01). Healthcare worker status associated with less acute inflammation (peak C reactive protein 48 mg/L (IQR: 14-165) vs 112 mg/L (52-181)), milder illness reflected by WHO clinical severity score distribution (p=0.04) and shorter duration of admission (4 days (IQR: 2-6) vs 6 days (3-12)).In adjusted multivariate logistic regression analysis, healthcare worker status associated with a binary classification (probable/very likely vs not present/unlikely) of adjudicated myocarditis (OR: 2.99; 95% CI (1.01 to 8.89) by 28-60 days postdischarge).After a mean (SD, range) duration of follow-up after hospital discharge of 450 (88) days (range 290, 627 days), fewer healthcare workers died or were rehospitalised (1 (3%) vs 22 (17%); p=0.038) and secondary care referrals for post-COVID-19 syndrome were common (42%) and similar to non-healthcare workers (38%; p=0.934). CONCLUSION Healthcare worker status was independently associated with the likelihood of adjudicated myocarditis, despite better antecedent health. Two in five healthcare workers had a secondary care referral for post-COVID-19 syndrome. TRIAL REGISTRATION NUMBER NCT04403607.
Collapse
|
2
|
United Kingdom standards for non-invasive cardiac imaging: recommendations from the Imaging Council of the British Cardiovascular Society. Heart 2022; 108:e7. [PMID: 35613713 DOI: 10.1136/heartjnl-2022-320799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Heart and circulatory diseases affect more than seven million people in the UK. Non-invasive cardiac imaging is a critical element of contemporary cardiology practice. Progressive improvements in technology over the last 20 years have increased diagnostic accuracy in all modalities and led to the incorporation of non-invasive imaging into many standard cardiac clinical care pathways. Cardiac imaging tests are requested by a variety of healthcare practitioners and performed in a range of settings from the most advanced hospitals to local health centres. Imaging is used to detect the presence and consequences of cardiovascular disease, as well as to monitor the response to therapies. The previous UK national imaging strategy statement which brought together all of the non-invasive imaging modalities was published in 2010. The purpose of this document is to collate contemporary standards developed by the modality-specific professional organisations which make up the British Cardiovascular Society Imaging Council, bringing together common and essential recommendations. The development process has been inclusive and iterative. Imaging societies (representing both cardiology and radiology) reviewed and agreed on the initial structure. The final document therefore represents a position, which has been generated inclusively, presents rigorous standards, is applicable to clinical practice and deliverable. This document will be of value to a variety of healthcare professionals including imaging departments, the National Health Service or other organisations, regulatory bodies, commissioners and other purchasers of services, and service users, i.e., patients, and their relatives.
Collapse
|
3
|
The ViKTORIES trial: A randomized, double-blind, placebo-controlled trial of vitamin K supplementation to improve vascular health in kidney transplant recipients. Am J Transplant 2021; 21:3356-3368. [PMID: 33742520 DOI: 10.1111/ajt.16566] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Revised: 02/24/2021] [Accepted: 03/13/2021] [Indexed: 01/25/2023]
Abstract
Premature cardiovascular disease and death with a functioning graft are leading causes of death and graft loss, respectively, in kidney transplant recipients (KTRs). Vascular stiffness and calcification are markers of cardiovascular disease that are prevalent in KTR and associated with subclinical vitamin K deficiency. We performed a single-center, phase II, parallel-group, randomized, double-blind, placebo-controlled trial (ISRCTN22012044) to test whether vitamin K supplementation reduced vascular stiffness (MRI-based aortic distensibility) or calcification (coronary artery calcium score on computed tomography) in KTR over 1 year of treatment. The primary outcome was between-group difference in vascular stiffness (ascending aortic distensibility). KTRs were recruited between September 2017 and June 2018, and randomized 1:1 to vitamin K (menadiol diphosphate 5 mg; n = 45) or placebo (n = 45) thrice weekly. Baseline demographics, clinical history, and immunosuppression regimens were similar between groups. There was no impact of vitamin K on vascular stiffness (treatment effect -0.23 [95% CI -0.75 to 0.29] × 10-3 mmHg-1 ; p = .377), vascular calcification (treatment effect -141 [95% CI - 320 to 38] units; p = .124), nor any other outcome measure. In this heterogeneous cohort of prevalent KTR, vitamin K supplementation did not reduce vascular stiffness or calcification over 1 year. Improving vascular health in KTR is likely to require a multifaceted approach.
Collapse
|
4
|
Role of inpatient coronary CT angiography on clinical decision making during COVID- 19 pandemic. Eur Heart J Cardiovasc Imaging 2021. [PMCID: PMC8344799 DOI: 10.1093/ehjci/jeab111.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Funding Acknowledgements
Type of funding sources: None.
Background
The COVID-19 pandemic has had a profound effect on healthcare delivery. Here we describe the effect of repurposing of a research Computed Tomography scanner on clinical care of cardiology patients in an urban academic medical centre which did not have routine access to CCTA prior to the pandemic.
Patients requiring invasive coronary angiography require transfer to a regional cardiac centre (no ICA available on site).
Purpose
We investigated the effect of CCTA on i) diagnostic certainty ii) avoidance of clinician defined unnecessary invasive angiography in hospitalised patients.
Methods
This was a prospective, longitudinal cohort study involving hospitalized patients admitted to an urban academic medical centre (catchment population 650 000) between March 29 and September 21, 2020. Routinely collected (usual care) data were gathered by clinicians who were members of the usual care medical team and ethics approval or explicit patient consent was not required. High-sensitivity Troponin-I was measured on admission and 3- and 6– hours after if mandated (Abbott Architect TnI assay).
A 320-detector scanner (Aquilon ONE, Canon) was used. Intravenous metoprolol was used where required to control the heart rate (target 60 b.p.m.) and sublingual glyceryl trinitrate will be given to all patients immediately before the scan acquisition.
Results
Forty-three patients underwent inpatient CCTA, mean age: 61 ± 13 years (range 30-88y), 54% female. The presenting complaint was typical chest pain in 28 (65%), atypical chest pain in 10 (23%), and a variety of symptoms in 5 (12%) including palpitations, syncope, breathlessness.
Thirty-six (84%) of patients had a detectable TnI above the 99% centile. Median(IQR) peak TnI was 127 (33-635)ng/L.
CCTA was carried out on average 1 day post request.
CCTA resulted in an improvement in clinician diagnostic certainty (Initial review: 21% yes, 79% probable, post-CCTA review: 84% yes, 16% probable) in providing a diagnosis.
21 (49%) of invasive coronary angiograms were avoided due to CCTA, whilst an inpatient invasive coronary angiogram (ICA) was performed in 4(9%) due to CCTA demonstrating significant disease, and in 2(%) the ICA was changed from out-patient to in-patient. Three ICA tests were requested as OP due to CCTA findings. CCTA did not overestimate disease severity in this cohort.
We saved 21 inter hospital transfers for ICA during this time period.
Using NHS England cost tariffs, a cost saving of >£36,000 was made for using CCTA instead of ICA in these 21 patients who would have required ICA.
Conclusion
Inpatient CCTA resulted in greater clinician diagnostic confidence, avoidance of unnecessary invasive angiograms and a significant cost saving. This also reduced the duration of patient stay, reducing the potential exposure of patients to COVID-19.
Collapse
|
5
|
Cardiovascular magnetic resonance for the detection of descending thoracic aorta calcification in patients with end-stage renal disease. J Cardiovasc Magn Reson 2021; 23:85. [PMID: 34162405 PMCID: PMC8223384 DOI: 10.1186/s12968-021-00769-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 05/04/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Vascular calcification is an independent predictor of cardiovascular disease in patients with chronic kidney disease. Computed tomography (CT) is the gold-standard for detecting vascular calcification. Radial volumetric-interpolated breath-hold examination (radial-VIBE), a free-breathing gradient-echo cardiovascular magnetic resonance (CMR) sequence, has advantages over CT as it is ionising radiation-free. However, its capability in detecting thoracic aortic calcification (TAC) has not been investigated. This study aims to compare radial-VIBE to CT for the detection of TAC in the descending aorta of patients with end-stage renal disease (ESRD) using semi-automated methods, and to investigate the association between TAC and coronary artery calcification (CAC). METHODS Paired cardiac CT and radial-VIBE CMR scans from ESRD patients participating in 2 prospective studies were obtained. Calcification volume was quantified using semi-automated methods in a 9 cm segment of the thoracic aorta. Correlation and agreement between TAC volume measured on CMR and CT were assessed with Spearman's correlation coefficient (ρ), linear regression, Bland-Altman plots and intraclass correlation coefficient (ICC). Association between CAC Agatston score and TAC volume determined by CT and CMR was measured with Spearman's correlation coefficient. RESULTS Scans from 96 participants were analysed. Positive correlation was found between CMR and CT calcification volume [ρ = 0.61, 95% confidence interval (CI) 0.45-0.73]. ICC for consistency was 0.537 (95% CI 0.378-0.665). Bland-Altman plot revealed that compared to CT, CMR volumes were systematically higher at low calcification volume, and lower at high calcification volume. CT did not detect calcification in 41.7% of participants, while radial-VIBE CMR detected signal which the semi-quantitative algorithm reported as calcification in all of those individuals. Instances of suboptimal radial-VIBE CMR image quality were deemed to be the major contributors to the discrepancy. Correlations between CAC Agatston score and TAC volume measured by CT and CMR were ρ = 0.404 (95% CI 0.214-0.565) and ρ = 0.211 (95% CI 0.008-0.396), respectively. CONCLUSION Radial-VIBE CMR can detect TAC with strong positive association to CT, albeit with the presence of proportional bias. Quantification of vascular calcification by radial-VIBE remains a promising area for future research, but improvements in image quality are necessary.
Collapse
|
6
|
Access to MRI for patients with cardiac pacemakers and implantable cardioverter defibrillators. Open Heart 2021; 8:e001598. [PMID: 34031214 PMCID: PMC8149430 DOI: 10.1136/openhrt-2021-001598] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Revised: 03/02/2021] [Accepted: 03/05/2021] [Indexed: 11/04/2022] Open
Abstract
OBJECTIVE To determine provision of MRI for patients with cardiac implantable electronic devices (CIEDs; pacemakers and defibrillators) in England, to understand regional variation and assess the impact of guideline changes. METHODS Retrospective data related to MRI scans performed in patients with CIED over the preceding 12 months was collected using a structured survey tool distributed to every National Health Service Trust MRI unit in England. Data were compared with similar data from 2014/2015 and with demand (estimated from local CIED implantation rates and regional population data by sustainability and transformation partnerships (STPs)). RESULTS Responses were received from 212 of 223 (95%) hospitals in England. 112 (53%) MRI units' scan patients with MR-conditional CIEDs (10% also scan non-MR conditional devices), compared with 46% of sites in 2014/2015. Total annual scan volume increased over fourfold between 2014 and 2019 (1090 to 4896 scans). There was widespread geographical variation, with five STPs (total population >3·5 million representing approximately 25 000 patients with CIED) with no local provision. There was no correlation between local demand (CIED implantation rates) and MRI provision (scan volume). Complication rates were extremely low with three events nationally in 12 months (0·06% CIED-MRI scans). CONCLUSIONS Provision of MRI for patients with CIEDs in England increased over fourfold in 4 years, but an estimated 10-fold care gap remains. Almost half of hospitals and 1 in 10 STPs have no service, with no relationship between local supply and demand. Availability of MRI for patients with non-MR conditional devices, although demonstrably safe, remains limited.
Collapse
|
7
|
Research priorities in cardiovascular imaging. Open Heart 2020; 7:openhrt-2020-001389. [PMID: 33046593 PMCID: PMC7552921 DOI: 10.1136/openhrt-2020-001389] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 08/14/2020] [Accepted: 08/17/2020] [Indexed: 11/11/2022] Open
Abstract
Aim A modified Delphi approach was used to develop consensus opinion among British Society for Cardiac Imaging/British Society of Cardiac CT (BSCI/BSCCT) members in order to prioritise research questions in cardiovascular imaging. Methods All members of the BSCI/BSCCT were invited to submit research questions that they considered to be of the highest clinical and/or academic priority in the field of cardiovascular imaging (phase 1). Subsequently a steering committee removed duplicate questions and combined questions of a similar theme by consensus agreement where appropriate. BSCI/BSCCT members were invited to rank the resulting research questions in two further iterative rounds (phases 2 and 3) to determine a final list of high-priority research questions. Results A total of 111 research questions were submitted in phase 1 by 30 BSCI/BSCCT members. While there was a broad range of topics, from determining the optimal features/markers of the vulnerable plaque to investigating how cardiac imaging can best be used to maximise clinical outcomes and economic costs, multimodality imaging-related (n=44, 40%) questions dominated the categories and coronary artery imaging (n=40, 36%) was the most common topic. Over two iterative rounds of prioritisation of these research questions, the original 111 were reduced to 75 questions in round 2, and 25 in round 3. From these 25 a final Top 10 list was distilled by consensus grouping. Conclusion This study has identified and ranked the top research priorities in cardiovascular imaging, as identified by the BSCI/BSCCT membership. This is a first step towards identifying the cardiovascular imaging research priorities within the UK and may assist researchers and funding bodies alike in setting priorities.
Collapse
|
8
|
Multicenter Safety and Practice for Off-Label Diagnostic Use of Ferumoxytol in MRI. Radiology 2019; 293:554-564. [PMID: 31638489 PMCID: PMC6884068 DOI: 10.1148/radiol.2019190477] [Citation(s) in RCA: 63] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Revised: 08/01/2019] [Accepted: 08/26/2019] [Indexed: 01/29/2023]
Abstract
Background Ferumoxytol is approved for use in the treatment of iron deficiency anemia, but it can serve as an alternative to gadolinium-based contrast agents. On the basis of postmarketing surveillance data, the Food and Drug Administration issued a black box warning regarding the risks of rare but serious acute hypersensitivity reactions during fast high-dose injection (510 mg iron in 17 seconds) for therapeutic use. Whereas single-center safety data for diagnostic use have been positive, multicenter data are lacking. Purpose To report multicenter safety data for off-label diagnostic ferumoxytol use. Materials and Methods The multicenter ferumoxytol MRI registry was established as an open-label nonrandomized surveillance databank without industry involvement. Each center monitored all ferumoxytol administrations, classified adverse events (AEs) using the National Cancer Institute Common Terminology Criteria for Adverse Events (grade 1-5), and assessed the relationship of AEs to ferumoxytol administration. AEs related to or possibly related to ferumoxytol injection were considered adverse reactions. The core laboratory adjudicated the AEs and classified them with the American College of Radiology (ACR) classification. Analysis of variance was used to compare vital signs. Results Between January 2003 and October 2018, 3215 patients (median age, 58 years; range, 1 day to 96 years; 1897 male patients) received 4240 ferumoxytol injections for MRI. Ferumoxytol dose ranged from 1 to 11 mg per kilogram of body weight (≤510 mg iron; rate ≤45 mg iron/sec). There were no systematic changes in vital signs after ferumoxytol administration (P > .05). No severe, life-threatening, or fatal AEs occurred. Eighty-three (1.9%) of 4240 AEs were related or possibly related to ferumoxytol infusions (75 mild [1.8%], eight moderate [0.2%]). Thirty-one AEs were classified as allergiclike reactions using ACR criteria but were consistent with minor infusion reactions observed with parenteral iron. Conclusion Diagnostic ferumoxytol use was well tolerated, associated with no serious adverse events, and implicated in few adverse reactions. Registry results indicate a positive safety profile for ferumoxytol use in MRI. © RSNA, 2019 Online supplemental material is available for this article.
Collapse
|
9
|
FO019FERUMOXYTOL MR ANGIOGRAPHY VS DOPPLER US FOR VASCULAR MAPPING BEFORE HAEMODIALYSIS ARTERIOVENOUS ACCESS CREATION. Nephrol Dial Transplant 2019. [DOI: 10.1093/ndt/gfz096.fo019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
10
|
FO039FERUMOXYTOL MR ANGIOGRAPHY VS CT ANGIOGRAPHY FOR THE ASSESSMENT OF POTENTIAL KIDNEY TRANSPLANT RECIPIENTS. Nephrol Dial Transplant 2019. [DOI: 10.1093/ndt/gfz096.fo039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
11
|
FP778CORRELATION OF ARTERIAL STIFFNESS, CALCIFICATION AND LEFT VENTRICULAR MASS INDEX IN RENAL TRANSPLANT RECIPIENTS: BASELINE ASSESSMENTS FROM A CLINICAL TRIAL. Nephrol Dial Transplant 2019. [DOI: 10.1093/ndt/gfz106.fp778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
12
|
T 1 hyperintensity on brain imaging subsequent to gadolinium-based contrast agent administration: what do we know about intracranial gadolinium deposition? Br J Radiol 2017; 90:20160590. [PMID: 27653560 PMCID: PMC5605029 DOI: 10.1259/bjr.20160590] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2016] [Revised: 09/13/2016] [Accepted: 09/19/2016] [Indexed: 11/05/2022] Open
Abstract
There is growing evidence for the accumulation of gadolinium (Gd) in patients administered with intravenous Gd-based contrast agents, even in the absence of renal impairment. This review of the literature will discuss what has been found to date in cadaveric human studies, clinical studies of patients and from animal models. Evidence for the potential route of entry into the brain will be examined. The current state of knowledge of effects of Gd accumulation in the brain is discussed. We will then discuss what the possible implications may be for the choice of Gd-based contrast agents in clinical practice.
Collapse
|
13
|
Abstract
In the past decade, impressive strides have been made in the diagnosis and management of atherosclerotic, aneurysmal, and thromboembolic diseases, thanks in large part to the explosive growth in both vascular biology and clinical vascular medicine. We review what we consider to be the top 12 advances in this field: the discovery of nitric oxide, the metabolic syndrome, new thrombophilic disorders, therapeutic angiogenesis, endoluminal treatment of chronic venous disease, and a variety of drugs, including sildenafil, cilostazol, low-molecular-weight heparins, oral direct thrombin inhibitors, clopidogrel, statins, and angiotensin-converting enzyme inhibitors and angiotensin-receptor blocking agents.
Collapse
|
14
|
Non-Contrast Renal Magnetic Resonance Imaging to Assess Perfusion and Corticomedullary Differentiation in Health and Chronic Kidney Disease. Nephron Clin Pract 2016; 133:183-92. [PMID: 27362585 DOI: 10.1159/000447601] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2016] [Accepted: 06/10/2016] [Indexed: 11/19/2022] Open
Abstract
AIMS Arterial spin labelling (ASL) MRI measures perfusion without administration of contrast agent. While ASL has been validated in animals and healthy volunteers (HVs), application to chronic kidney disease (CKD) has been limited. We investigated the utility of ASL MRI in patients with CKD. METHODS We studied renal perfusion in 24 HVs and 17 patients with CKD (age 22-77 years, 40% male) using ASL MRI at 3.0T. Kidney function was determined using estimated glomerular filtration rate (eGFR). T1 relaxation time was measured using modified look-locker inversion and xFB02;ow-sensitive alternating inversion recovery true-fast imaging and steady precession was performed to measure cortical and whole kidney perfusion. RESULTS T1 was higher in CKD within cortex and whole kidney, and there was association between T1 time and eGFR. No association was seen between kidney size and volume and either T1, or ASL perfusion. Perfusion was lower in CKD in cortex (136 ± 37 vs. 279 ± 69 ml/min/100 g; p < 0.001) and whole kidney (146 ± 24 vs. 221 ± 38 ml/min/100 g; p < 0.001). There was significant, negative, association between T1 longitudinal relaxation time and ASL perfusion in both the cortex (r = -0.75, p < 0.001) and whole kidney (r = -0.50, p < 0.001). There was correlation between eGFR and both cortical (r = 0.73, p < 0.01) and whole kidney (r = 0.69, p < 0.01) perfusion. CONCLUSIONS Significant differences in renal structure and function were demonstrated using ASL MRI. T1 may be representative of structural changes associated with CKD; however, further investigation is required into the pathological correlates of reduced ASL perfusion and increased T1 time in CKD.
Collapse
|
15
|
FP219COMPREHENSIVE ASSESSMENT OF KIDNEY ANATOMY AND PERFUSION WITH ARTERIAL SPIN LABELING MAGNETIC RESONANCE IMAGING. Nephrol Dial Transplant 2015. [DOI: 10.1093/ndt/gfv173.01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
16
|
Diagnosing nephrogenic systemic fibrosis in the post-FDA restriction era. J Magn Reson Imaging 2014; 41:1268-71. [DOI: 10.1002/jmri.24664] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2014] [Revised: 04/30/2014] [Accepted: 04/30/2014] [Indexed: 11/11/2022] Open
|
17
|
Inter-study reproducibility of arterial spin labelling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla. BMC Nephrol 2014; 15:23. [PMID: 24484613 PMCID: PMC3909760 DOI: 10.1186/1471-2369-15-23] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2013] [Accepted: 01/28/2014] [Indexed: 01/05/2023] Open
Abstract
BACKGROUND Measurement of renal perfusion is a crucial part of measuring kidney function. Arterial spin labelling magnetic resonance imaging (ASL MRI) is a non-invasive method of measuring renal perfusion using magnetised blood as endogenous contrast. We studied the reproducibility of ASL MRI in normal volunteers. METHODS ASL MRI was performed in healthy volunteers on 2 occasions using a 3.0 Tesla MRI scanner with flow-sensitive alternating inversion recovery (FAIR) perfusion preparation with a steady state free precession (True-FISP) pulse sequence. Kidney volume was measured from the scanned images. Routine serum and urine biochemistry were measured prior to MRI scanning. RESULTS 12 volunteers were recruited yielding 24 kidneys, with a mean participant age of 44.1 ± 14.6 years, blood pressure of 136/82 mmHg and chronic kidney disease epidemiology formula estimated glomerular filtration rate (CKD EPI eGFR) of 98.3 ± 15.1 ml/min/1.73 m2. Mean kidney volumes measured using the ellipsoid formula and voxel count method were 123.5 ± 25.5 cm3, and 156.7 ± 28.9 cm3 respectively. Mean kidney perfusion was 229 ± 41 ml/min/100 g and mean cortical perfusion was 327 ± 63 ml/min/100 g, with no significant differences between ASL MRIs. Mean absolute kidney perfusion calculated from kidney volume measured during the scan was 373 ± 71 ml/min. Bland Altman plots were constructed of the cortical and whole kidney perfusion measurements made at ASL MRIs 1 and 2. These showed good agreement between measurements, with a random distribution of means plotted against differences observed. The intra class correlation for cortical perfusion was 0.85, whilst the within subject coefficient of variance was 9.2%. The intra class correlation for whole kidney perfusion was 0.86, whilst the within subject coefficient of variance was 7.1%. CONCLUSIONS ASL MRI at 3.0 Tesla provides a repeatable method of measuring renal perfusion in healthy subjects without the need for administration of exogenous compounds. We have established normal values for renal perfusion using ASL MRI in a cohort of healthy volunteers.
Collapse
|
18
|
Nephrogenic systemic fibrosis: review of 370 biopsy-confirmed cases. JACC Cardiovasc Imaging 2012; 4:1206-16. [PMID: 22093272 DOI: 10.1016/j.jcmg.2011.08.013] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2011] [Revised: 08/23/2011] [Accepted: 08/23/2011] [Indexed: 10/15/2022]
Abstract
Discovery of an association between gadolinium-based contrast agents (GBCAs) and nephrogenic systemic fibrosis (NSF) has led to less use of GBCA-enhanced magnetic resonance imaging in dialysis patients and patients with severe renal failure at risk of NSF, and the virtual elimination of new cases of NSF. But shifting patients with renal failure to alternative imaging methods may subject patients to other risks (e.g., ionizing radiation or iodinated contrast). This review paper examines 370 NSF cases reported in 98 articles to analyze NSF risk factors. Eliminating multiple risk factors by limiting GBCA dose to a maximum of 0.1 mmol/kg, dialyzing patients undergoing dialysis quickly following GBCA administration, delaying GBCA in acute renal failure until after renal function returns or dialysis is initiated, and avoiding nonionic linear GBCA in patients with renal failure especially when there are proinflammatory conditions may substantially reduce the risk of NSF.
Collapse
|
19
|
Abstract
Peripheral arterial disease is usually secondary to stenotic or occlusive atherosclerosis and is both common and increasing in western society. The majority of symptomatic patients have intermittent claudication and only a minority (<2% and typically those with diabetes mellitus or renal failure) progress to critical limb ischaemia, heralded by the onset of rest pain and/or tissue loss. Imaging is largely reserved for patients with disabling symptoms in whom revascularisation is planned. In these patients, accurate depiction of the vascular anatomy is critical for clinical decision making as the distribution and severity of disease are key factors determining whether revascularisation should be by endovascular techniques or open surgery. Driven by advances in technology, non-invasive vascular imaging has recently undergone significant refinement and has replaced conventional digital subtraction angiography for many clinical indications. In this review, the relative merits and limitations of duplex ultrasound, CT angiography, and magnetic resonance angiography are discussed, emerging imaging techniques are described, and complications relating to the use of intravascular contrast agents are highlighted.
Collapse
|
20
|
An S-shaped sinoatrial nodal artery coronary artery fistula demonstrated by multidetector CT. Br J Radiol 2011; 84:e88-90. [PMID: 21224306 DOI: 10.1259/bjr/17451817] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The presented case and discussion illustrate the use of CT coronary angiography to depict coronary artery fistulae. A 41-year-old man presented with an acute myocardial infarction. Invasive angiography revealed an incidental coronary artery fistula but was unable to depict its course. CT coronary angiography was undertaken to define the course and termination of the fistula. This confirmed a fistulous connection between the left circumflex artery and the superior vena cava that followed the typical course of an S-shaped sinoatrial nodal artery. Even in such an unusual anomaly this case highlights the ability of CT coronary angiography to accurately depict the coronary artery anatomy.
Collapse
|
21
|
Abstract
Emerging evidence linking gadolinium-based contrast agents (GBCAs) to nephrogenic systemic fibrosis (NSF) has changed medical practice patterns toward forgoing GBCA-enhanced magnetic resonance imaging (MRI) or substituting other imaging methods, which are potentially less accurate and often radiation-based. This shift has been based on reports of high NSF incidence at sites where a confluence of risk factors occurred in patients with severe renal dysfunction. This review article explores the factors that affect NSF risk, compares risks of alternative imaging procedures, and demonstrates how risk can be managed by careful selection of GBCA dose, timing of injection with respect to dialysis, and other factors. Nearly half of NSF cases are a milder form that does not cause contractures or reduce mobility. It appears that eliminating even a single risk factor can reduce NSF incidence/risk at least 10-fold. Elimination of multiple risk factors by using single-dose GBCA, dialyzing dialysis patients quickly following GBCA administration, avoiding GBCA in acute renal failure while serum creatinine is rising, and avoiding nonionic linear GBCA in renal failure patients may reduce NSF risk more than a thousand-fold, thereby allowing safe GBCA-enhanced MRI in virtually all patients. J. Magn. Reson. Imaging 2009;30:1298-1308. (c) 2009 Wiley-Liss, Inc.
Collapse
|
22
|
Imaging in endovascular therapy: our future. J Endovasc Ther 2009; 16 Suppl 1:I22-41. [PMID: 19317577 DOI: 10.1583/08-2598.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
The endovascular therapist now has many modern imaging techniques available to plan and execute treatment, whereas in the past vascular surgeons relied mostly on clinical examination and arteriography. Advances in computer technology have enabled fast acquisition and processing of the large amounts of digital data essential to capture the dynamic information from fast-flowing blood at high resolution. Functional imaging has begun to play a role in predicting stability of progressive vascular disease and the need for and risks of intervention. Computing power now affords the interventionist the ability to handle imaging data in powerful 3-dimensional programs and electronically "in-lay" a variety of devices to plan complex endovascular procedures from the familiar platform of a laptop. In four major clinical areas, carotid intervention, peripheral intervention, endoluminal grafting, and cardiac imaging, we review the latest advances and changes with an eye toward how we should best be using imaging in our patients undergoing endovascular treatment...now and into the future.
Collapse
|
23
|
Carotid artery stenosis: accuracy of noninvasive tests--individual patient data meta-analysis. Radiology 2009; 251:493-502. [PMID: 19276319 DOI: 10.1148/radiol.2512080284] [Citation(s) in RCA: 71] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
PURPOSE To find clinically relevant estimates of the accuracy of noninvasive imaging-Doppler ultrasonography (US), computed tomographic (CT) angiography, magnetic resonance (MR) angiography, and contrast material-enhanced MR angiography-in diagnosing both severe and moderate symptomatic carotid artery stenosis; to ascertain the effect of prespecified clinical factors and clinical setting on diagnostic accuracy; and to estimate the probability of agreement between two noninvasive tests. MATERIALS AND METHODS Original principal investigators obtained ethics approval for each data set. All data were anonymized. Individual patient data sets (IPDs) for noninvasive imaging tests were used to determine sensitivity, specificity, and agreement between the tests for symptomatic carotid artery stenosis; to compare ipsilateral with contralateral arteries; to compare IPDs with literature estimates; to compare routine audit and research data; and to determine the effect of age and sex on sensitivity and specificity. RESULTS Contrast-enhanced MR angiography was the most accurate (sensitivity, 0.85 [30 of 35]; 95% confidence interval [CI]: 0.69, 0.93; and specificity, 0.85 [67 of 78]; 95% CI: 0.76, 0.92) for 70%-99% symptomatic stenosis. Sensitivity for a 50%-69% stenosis was poor, although data were limited. Sensitivity and specificity were generally lower in the ipsilateral than in the contralateral artery. IPD estimates were lower than literature values. Results of comparison of research with audit-derived data were inconclusive. Neither age nor sex affected accuracy. Agreement was better between two Doppler US tests and between two contrast-enhanced MR angiographic tests than it was between Doppler US and contrast-enhanced MR angiography, except for a 70%-99% symptomatic stenosis. CONCLUSION Primary studies should distinguish ipsilateral from contralateral arteries and carefully describe the patients' characteristics and study environment. The literature overestimates noninvasive imaging accuracy. More data are needed to inform physicians in routine clinical practice.
Collapse
|
24
|
Images in cardiovascular medicine. Bursting forth: late-developing acute mediastinal abscess after sternotomy demonstrated by cardiac computed tomography. Circulation 2008; 118:e673-4. [PMID: 18936333 DOI: 10.1161/circulationaha.108.784017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
25
|
Abstract
Vascular imaging techniques, such as catheter angiography, ultrasound, computed tomography (CT), and magnetic resonance (MR), have all undergone unprecedented innovation and incredible technological leaps in the last 10 years. Ultrasound, CT, and MR have progressed in acquisition speed, resolution, and accuracy to the point that they have now supplanted the former mainstay, invasive catheter-based angiography, despite the advent of digitized angiographic image recording. This review explores the advantages and shortcomings of each technique and how they have changed the diagnosis and assessment of the cardiovascular system for endovascular intervention.
Collapse
|
26
|
Picture quiz. IMAGING 2004. [DOI: 10.1259/imaging/17004493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
27
|
Magnetic resonance angiography and computed tomography angiography for peripheral arterial disease. IMAGING 2004. [DOI: 10.1259/imaging/59636918] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
28
|
MRI changes in myocarditis--evaluation with spin echo, cine MR angiography and contrast enhanced spin echo imaging. Clin Radiol 2000; 55:752-8. [PMID: 11052875 DOI: 10.1053/crad.2000.0519] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
AIM Myocarditis is probably under-diagnosed with clinical criteria generally used for diagnosis. Magnetic resonance imaging (MRI) has shown promise in detecting heart muscle disorders and we set out to assess the role of cine magnetic resonance angiography (MRA) and contrast enhancement in myocarditis, as there is a need for a non-invasive tool that can aid prognosis and follow-up. MATERIALS AND METHODS Twenty patients were evaluated with T1 SE pre- and post-gadolinium enhancement and cine MRA. Four patients were histologically proven to have myocarditis, eight others were diagnosed as having myocarditis by clinical criteria and eight did not have myocarditis. Images were evaluated in a blinded fashion for regional wall motion abnormality and contrast enhancement pattern. Analysis of contrast enhancement by signal intensity measurement was also performed. RESULTS Focal myocardial enhancement with associated regional wall motion abnormality correlated with myocarditis in 10 out of 12 patients, two patients with abnormal focal enhancement alone also clinically had myocarditis. None of the non-myocarditis patients showed abnormal focal enhancement. Enhancement analysis suggests that focal corrected myocardial enhancement of > 40% is abnormal. CONCLUSION In the correct clinical context, focal myocardial enhancement on spin echo MRI strongly supports a diagnosis of myocarditis, especially when associated with regional wall motion abnormality.Roditi, G. H. (2000). Clinical Radiology55, 752-758.
Collapse
|
29
|
Abstract
AIM Inflammatory abdominal aortic aneurysms (IAAA) are a variant of abdominal aortic aneurysms, which are associated with an increased morbidity. The diagnosis of IAAA has traditionally been established with a combination of clinical and laboratory findings together with contrast enhanced CT. There is a high incidence of renal impairment in this group, and therefore contrast enhanced CT may be harmful. PATIENTS AND METHODS Five patients with IAAA underwent T1-weighted spin echo and gradient echo gadolinium enhanced abdominal MRI. A total of eight examinations were performed, including three patients who underwent repeat MRI following steroid therapy. RESULTS The inflammatory cuff was clearly identified following gadolinium administration in all eight examinations. The cuff enhanced homogeneously in all patients with no alteration in appearance following steroid therapy. The intravenous administration of gadolinium DTPA enabled clearer definition of locally involved structures. CONCLUSION Gadolinium enhanced MRI readily demonstrates features of IAAA. In view of potential renal impairment in this patient group, we recommend this technique in preference to contrast enhanced CT in the initial investigation of inflammatory abdominal aortic aneurysms.
Collapse
|
30
|
Abstract
Magnetic resonance imaging (MRI) of the temporomandibular joint (TMJ) has been most commonly performed using spin-echo sequences. Gradient-echo sequences have previously been investigated in the context of 3-D and 'dynamic' (pseudo-kinematic) imaging. We have used gradient-echo to improve image quality in static studies with rapid acquisition, high spatial resolution (512 x 512 matrix) and excellent contrast resolution. Using pragmatic methods and a non-randomized study group we have demonstrated a definite advantage to image quality, and thus diagnostic confidence, from the use of a gradient-echo high spatial resolution sequence incorporating split acquisition open mouth views.
Collapse
|
31
|
Abstract
The examinations of 71 patients having comprehensive 2D time of flight (TOF) abdominal magnetic resonance venography (MRV) in three planes (axial, sagittal and 10 degrees offset coronal) were evaluated to assess the appearances of anomalous left renal veins as shown by MRV. Six cases of circumaortic left renal vein (CLRV) (8.5%) and one example of retro-aortic left renal vein only (1.4%) were identified, an incidence higher than that in previous computed tomography (CT) studies but comparable to venographic and post-mortem investigations. All retro-aortic components passed in a caudal direction to join the inferior vena cava (IVC) inferior to the anterior limb. MRV acquired in the sagittal plane was found to be most useful for identifying these variants and provided highest signal by avoidance of in-plane flow saturation effects.
Collapse
|
32
|
Measurement of lower limb blood flow in patients with neurogenic claudication using positron emission tomography. Spine (Phila Pa 1976) 1995; 20:408-11. [PMID: 7747223 DOI: 10.1097/00007632-199502001-00002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Ten subjects (seven with neurogenic claudication and three control subjects) underwent examination of lower limb muscle blood flow before and after exercise using positron emission tomography. OBJECTIVES To investigate the hypothesis that lower limb muscle ischemia was the origin of symptoms in neurogenic claudication. BACKGROUND Patients with neurogenic claudication secondary to spinal stenosis experience lower limb discomfort after exercise similar to that of ischemic claudication. However, they do not have clinical evidence of peripheral vascular disease. The authors postulated that the lower limb discomfort in patients with neurogenic claudication may arise from muscle ischemia due to inadequate dilatation of arterioles in response to exercise, this itself arising secondary to sympathetic dysfunction due to spinal stenosis. METHOD Using O15-labeled water and positron emission tomography measured thigh and leg muscle blood flow response to exercise bilaterally in seven patients with unilateral neurogenic claudication and three control subjects were measured. RESULTS The average values obtained for mid-thigh and mid-calf muscle perfusion at rest were 2.57 ml/min/100 g tissue (2.23-3.90) and 2.39 ml/min/100 g tissue (2.03-3.46), respectively. The average values obtained from mid-thigh and mid-calf perfusion after exercise were 4.41 ml/min/100 g tissue (2.8-6.0) and 4.87 ml/min/100 g (2.2-11.7). We found no difference in muscle perfusion between symptomatic and asymptomatic limbs in this group of patients. CONCLUSION These studies suggest that muscle ischemia is not the origin of symptoms in most patients with neurogenic claudication.
Collapse
|
33
|
Abstract
This study set out to determine the frequency of tracheomegaly in brochiectasis as judged by high resolution computed tomography (HRCT) while determining whether the published normal tracheal dimensions derived from radiographic data can be used for CT diagnosis. Seventy-five consecutive adults referred for CT assessment of possible bronchiectasis were studied and compared with a control group of 75 adults being staged for lymphoma. The internal tracheal diameters at aortic arch level of the control group correspond with published radiographic data and using these measurements, 7/42 (17%) patients with bronchiectasis were found to have tracheomegaly, while two of the 33 'symptomatic' patients (i.e. those patients not found to have bronchiectasis) had tracheomegaly. Further analysis confirmed that the bronchiectatic group's tracheal dimensions were significantly different from those of the control group while the 'symptomatic' group are an overlap population. We conclude that tracheomegaly is a frequent finding in bronchiectasis.
Collapse
|
34
|
Evaluation of tilted, optimized, non-saturating excitation pulses in 3D magnetic resonance angiography of the abdominal aorta and major branches in volunteers. Br J Radiol 1994; 67:11-3. [PMID: 8298866 DOI: 10.1259/0007-1285-67-793-11] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Abstract
Ten normotensive volunteers were imaged with FISP-3D (Fast Imaging Steady Precession) pulse sequences (a steady state gradient recalled echo, SS-GRE, technique) without and with modification by tilted, optimized non-saturating excitation (TONE) customized radio frequency (RF) pulses, for evaluation of the abdominal aorta--in particular the renal arteries. Maximum intensity projection (MIP) angiograms were constructed for each sequence in each volunteer; 15 observers "blinded" to sequence type preferred the images generated from the TONE applied sequence. Analysis showed that this preference was significant.
Collapse
|