1
|
The Use of a Commercially Available Endovascular Filter Catheter (Capturex ®) for Thoracic Endovascular Aortic Repair (TEVAR) in a Patient with a Coral Reef Aorta. Cardiovasc Intervent Radiol 2022; 45:879-883. [PMID: 35476090 PMCID: PMC9117348 DOI: 10.1007/s00270-022-03147-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 03/31/2022] [Indexed: 11/24/2022]
Abstract
Due to the risk of mobilizing plaque fragments, transfemoral TEVAR is a potentially dangerous procedure in patients with a coral reef aorta. We describe a practical method for transfemoral TEVAR in a patient with a degenerative thoracic aneurysm and a coral reef aorta. After placing a filter catheter in the abdominal aorta via a contralateral percutaneous femoral access, a working channel through the distal thoracic aorta was created with a balloon-expandable stent graft in the coral reef segment. Thereafter, transfemoral TEVAR could be performed successfully, without any complications. The additional use of a percutaneously placed filter catheter potentially allows reduction of peripheral embolism and hence may prevent patients from more invasive treatment.
Collapse
|
2
|
Placement of hemoparin-coated stents in the iliac arteries: early experience and midterm results in 28 patients. Eur J Radiol 2014; 83:1205-1208. [PMID: 24815747 DOI: 10.1016/j.ejrad.2014.04.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2013] [Revised: 03/17/2014] [Accepted: 04/01/2014] [Indexed: 11/17/2022]
Abstract
PURPOSE Aim was to determine immediate results and mid-term outcome of the hemoparin-coated (HC) stainless-steel stent (camouflage coating) in the treatment of occlusive lesions of the iliac arteries. MATERIALS AND METHODS Twenty-eight patients were prospectively treated with the use of a HC stent between January 2007 and March 2010. Clinical examination and color-doppler ultrasound were performed at 1, 3, 6 and 12 months, CT angiography (CTA) or MR angiography (MRA) at 12 months. Indication for treatment was a high-grade stenosis of the common iliac and/or external iliac artery. RESULTS Successful placement was achieved in all patients. Significant decrease in translesional pressure gradient (>10 mm Hg) was measured in 27 patients (96%). In one patient, proximal dissection occurred without flow limitation. A minor complication (small access site hematoma) occurred in one patient (4%). Two patients (7%) were lost to follow-up. After 12 months, stent patency in CTA, MRA and ultrasound was 100%. 20 patients (77%) experienced an initial improvement of at least one clinical stage. In one patient (4%), mild intimal hyperplasia without significant stenosis was observed. In three patients (12%), proximal or distal stenosis occurred. A non-significant increase of mean ankle-brachial index (ABI) after treatment was measured (0.85 ± 0.27 vs. 0.75 ± 0.22, respectively; p=0.328). CONCLUSIONS The use of HC stents in patients with iliac artery occlusive disease may lead to a lower rate of intimal hyperplasia and thus to increased patency rates even in heavily calcified vessels. However, large-scale prospective trials have to be performed to evaluate the long-term patency rates of the HC coated stents.
Collapse
|
3
|
Die Effizienz der empirischen Bronchialarterienembolisation zur Behandlung der schweren Hämotpyse. ROFO-FORTSCHR RONTG 2012. [DOI: 10.1055/s-0032-1324416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
4
|
Long-term follow-up after treatment of intracranial aneurysms with the Pipeline embolization device: results from a single center. AJNR Am J Neuroradiol 2011; 33:481-6. [PMID: 22158922 DOI: 10.3174/ajnr.a2790] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Stent-like, self-expandable devices, the so-called flow diverters, are increasingly used for the treatment of wide-neck cerebral aneurysms. The immediate and short-term results are promising, but no long-term results are available. The purpose of our research was to report the long-term angiographic and cross-sectional imaging results after placement of a PED in 12 patients with wide-neck intracranial aneurysms. MATERIALS AND METHODS Twelve wide-neck or otherwise untreatable cerebral aneurysms in 12 patients were treated with the PED. Angiography was performed at 6 and 24 months after treatment. Additional MR and CT angiograms were acquired. RESULTS In all patients, angiographic or cross-sectional imaging follow-up of at least 27 months demonstrated complete occlusion of the aneurysms treated with the PED. There were no cases of aneurysm recurrence. Angiography at around 6 months showed complete occlusion in all cases, except 1 that showed complete occlusion at the 29-month follow-up. In 1 patient, a clinically asymptomatic 75% in-stent stenosis was seen on the angiography at 6 months but was resolved completely by balloon dilation. Device placement was successful in all patients. Distal embolization had occurred in 1 patient, but the clot was resolved completely without clinical sequelae. Almost immediate angiographic occlusion was achieved in 2 aneurysms and flow reduction in 10 aneurysms. CONCLUSIONS Treatment of wide-neck intracranial aneurysms by PED placement led to successful and durable occlusion in all cases, without severe complications. Endovascular treatment for in-stent stenosis should be considered cautiously, because the underlying stenosis may be transient and disappear within 12 months after treatment.
Collapse
|
5
|
Acute pulmonary embolism: Comparison of standard axial MDCT with paddlewheel technique. Eur J Radiol 2008; 66:31-6. [PMID: 17606350 DOI: 10.1016/j.ejrad.2007.05.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2007] [Revised: 04/23/2007] [Accepted: 05/23/2007] [Indexed: 10/23/2022]
Abstract
PURPOSE The purpose of this study was to evaluate the ability of rotated paddlewheel reformations for the detection of central and peripheral pulmonary embolism (PE) compared to standard axial multi detector CT (MDCT) images. MATERIAL AND METHODS CT scans of 35 patients with PE were reviewed by three independent readers for the detection of pulmonary emboli using standard axial CT scans and reformatted paddlewheel technique. All images were evaluated in random order. MDCT examinations were performed with a collimation of 1.25 mm, a pitch of six and a reconstruction interval of 0.8mm. For each patient MIP were reformatted by using a paddlewheel arrangement with 5mm slab thickness and 5 degrees rotation. Standard of reference for PE was a consensus reading of the axial images by all three readers. RESULTS The overall sensitivity for the axial images for the three readers ranged between 91% and 96%; for paddlewheel reformations from 78% to 83%; the specificity for both methods was 98-99%. Inter- and intraobserver agreement was also higher for axial images than for paddlewheel reformations. CONCLUSION Comparing standard axial MDCT scans and reformatted paddlewheel images no significant difference for the detection of central PE was found, whereas for the detection of peripheral emboli standard axial images showed a significant higher percentage of detecting PE than paddlewheel reformations.
Collapse
|
6
|
Diagnostische Genauigkeit der 3D TOF MRA im Vergleich zur DSA für die Nachkontrolle von Patienten mit endoluminal behandelten intrakraniellen Aneurysmen: Einfluss von Aneurysmagröße und Lokalisation. ROFO-FORTSCHR RONTG 2008. [DOI: 10.1055/s-2008-1073857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
7
|
[Pelizaeus-Merzbacher-caused diseases in Connexin 46 mutation: a rare form of leukodystrophy]. ROFO-FORTSCHR RONTG 2007; 179:637-8. [PMID: 17492548 DOI: 10.1055/s-2007-963009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
8
|
Diagnostic accuracy of 3D time-of-flight MR angiography compared with digital subtraction angiography for follow-up of coiled intracranial aneurysms: influence of aneurysm size. AJNR Am J Neuroradiol 2007; 28:628-34. [PMID: 17416811 PMCID: PMC7977342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
BACKGROUND AND PURPOSE 3D time-of-flight MR angiography (3D TOF MRA) may be used as noninvasive alternative to digital subtraction angiography (DSA) for the follow-up of patients with intracranial aneurysms treated with Guglielmi detachable coils (GDCs). We aimed to determine the influence of aneurysm size and location on diagnostic accuracy of 3D TOF MRA for follow-up of intracranial aneurysms treated with GDCs. MATERIALS AND METHODS Two hundred and one 3D TOF MRAs in 127 consecutive patients with 136 aneurysms were compared with DSA as standard of reference. Sensitivity and specificity of 3D TOF MRA for detection of residual or reperfusion of the aneurysms was calculated with regard to aneurysm size and location. RESULTS Overall sensitivity and specificity of MRA was 88.5% and 92.9%, respectively. Sensitivity was lower for aneurysms <or=5 mm (72.2%) and <or=3 mm (63.6%). In addition to the small aneurysm size, interpretation of MR angiograms was compromised by susceptibility artifacts at the air-bone interface, arterial overlap, and pulsation-induced artifacts. The small number of disagreements between MRA and DSA hampered reliable interpretation of the possible influence of aneurysm location on MRA accuracy. CONCLUSION The sensitivity of 3D TOF MRA for detection of reperfusion or residual perfusion of coiled intracranial aneurysms varies considerably depending on the size of the aneurysms. No conclusions can be drawn regarding a possible influence of aneurysm location on diagnostic accuracy of 3D TOF MRA. These findings may influence the decision about whether to replace DSA by 3D TOF MRA for the follow-up of patients with intracranial aneurysms treated with GDCs.
Collapse
|
9
|
Endoluminal therapy in patients with peripheral arterial disease: prospective assessment of quality of life in 190 patients. AJR Am J Roentgenol 2007; 188:169-75. [PMID: 17179360 DOI: 10.2214/ajr.05.1408] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The objective of our study was to assess the impact of endoluminal treatment on health-related quality of life in patients with peripheral arterial disease. SUBJECTS AND METHODS Changes in quality of life were prospectively evaluated in 190 patients before and 1, 3, 6, and 12 months after treatment. Physical, emotional, and general health components were determined using the short-form (36 items) health survey (SF-36). Claudicant patients were compared with patients who had critical limb ischemia. The influence of the lesion location (iliac, femoropopliteal, or crural) restenosis, and additional interventions on quality of life were evaluated. RESULTS Six- and 12-month follow-up data were available for 136 and 103 patients, respectively. Significant improvements in quality of life were observed in most of the patients after the intervention. Many of the SF-36 scores decreased from the 6- to the 12-month follow-up but remained significantly higher than the score before the intervention. Reduction of bodily pain was the most evident effect of treatment. Claudicant patients seemed to benefit more from treatment than patients with critical limb ischemia. In terms of SF-36 scores, percutaneous transluminal angioplasty of the crural arteries was equally as effective as endoluminal revascularization of the iliac and femoropopliteal arteries and multilevel interventions were as effective as single-level interventions. The occurrence of a restenosis was significantly related to lower SF-36 scores, and restenosis not followed by a second intervention was associated with lower SF-36 scores. CONCLUSION Although there were several differences between the groups, significant improvements in quality of life up to 12 months after endoluminal therapy were observed in most patients.
Collapse
|
10
|
[Isolated tracheobronchial amyloidosis: a rare cause of a hilar space-occupying lesion]. ROFO-FORTSCHR RONTG 2006; 178:1264-6. [PMID: 17136653 DOI: 10.1055/s-2006-927057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
11
|
Routine Use of Three-Dimensional Contrast-Enhanced Moving-Table MR Angiography in Patients with Peripheral Arterial Occlusive Disease: Comparison with Selective Digital Subtraction Angiography. Cardiovasc Intervent Radiol 2006; 29:762-70. [PMID: 16625410 DOI: 10.1007/s00270-004-0309-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To compare the diagnostic accuracy of contrast-enhanced (CE) three-dimensional (3D) moving-table magnetic resonance (MR) angiography with that of selective digital subtraction angiography (DSA) for routine clinical investigation in patients with peripheral arterial occlusive disease. METHODS Thirty-eight patients underwent CE 3D moving-table MR angiography of the pelvic and peripheral arteries. A commercially available large-field-of-view adapter and a dedicated peripheral vascular phased-array coil were used. MR angiograms were evaluated for grade of arterial stenosis, diagnostic quality, and presence of artifacts. MR imaging results for each patient were compared with those of selective DSA. RESULTS Two hundred and twenty-six arterial segments in 38 patients were evaluated by both selective DSA and MR angiography. No complications related to MR angiography were observed. There was agreement in stenosis classification in 204 (90.3%) segments; MR angiography overgraded 16 (7%) segments and undergraded 6 (2.7%) segments. Compared with selective DSA, MR angiography provided high sensitivity and specificity and excellent interobserver agreement for detection of severe stenosis (97% and 95%, kappa = 0.9 +/- 0.03) and moderate stenosis (96.5% and 94.3%, kappa = 0.9 +/- 0.03). CONCLUSION Compared with selective DSA, moving-table MR angiography proved to be an accurate, noninvasive method for evaluation of peripheral arterial occlusive disease and may thus serve as an alternative to DSA in clinical routine.
Collapse
|
12
|
MDCT Angiography of the Pulmonary Arteries: Influence of Body Weight, Body Mass Index, and Scan Length on Arterial Enhancement at Different Iodine Flow Rates. AJR Am J Roentgenol 2006; 187:1074-8. [PMID: 16985159 DOI: 10.2214/ajr.05.0714] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
OBJECTIVE The purpose of this study was to assess whether body weight, body mass index, and scan length influence arterial enhancement during CT angiography (CTA) of the pulmonary arteries at different iodine flow rates. MATERIALS AND METHODS CTA examinations of the pulmonary arteries performed for routine clinical care of 120 patients between March and December 2003 were retrospectively evaluated. Patients had received either 120 mL of contrast medium with an iodine concentration of 300 mg I/mL (group A) or 90 mL of contrast medium with an iodine concentration of 400 mg I/mL (group B). The iodine dose was 36 g, and the injection rate was 4 mL/s in all examinations. The iodine flow rate was 1.2 g I/s in group A and 1.6 g I/s in group B. Arterial attenuation along the z-axis was measured per patient, and the influence of body weight, body mass index, and scan length on enhancement of the pulmonary arteries in the two groups was assessed. RESULTS In group A and in group B, body weight and body mass index correlated significantly with mean enhancement along the z-axis (r = -0.35 and -0.26 for group A and -0.48 and -0.40 for group B). Scan length showed no correlation with pulmonary attenuation. Mean pulmonary artery enhancement was significantly higher in group B with a difference of 51 H compared with group A. CONCLUSION Pulmonary artery attenuation in CTA of the pulmonary arteries shows a small but significant correlation with body weight and body mass index independently of the iodine flow rate used. A higher iodine flow rate improves pulmonary artery enhancement.
Collapse
|
13
|
Abstract
OBJECTIVE Our objective was to define typical MRI findings of the wrist and the hand in patients with psoriatic arthritis (PsA) and rheumatoid arthritis (RA). MATERIALS AND METHODS Eighteen PsA and 21 RA patients with arthralgia of the wrist or hand joints underwent gadolinium-enhanced MRI of the wrist and hand. Two experienced radiologists interpreted abnormalities in consensus with respect to periarticular soft-tissue swelling, synovitis with or without effusion, periostitis, bone edema, bone erosions, bone cysts, and tenosynovitis. The distribution of the abnormalities also was evaluated. RESULTS Erosions were statistically more frequent in patients with RA (p < 0.05). Periostitis was statistically seen more frequently in patients with PsA (p < 0.05). No statistically significant difference was found in the frequency of synovitis, bone marrow edema, bone cysts, and tenosynovitis between the two groups (p > 0.05). The radiocarpal joint, the midcarpal joints, the carpometacarpal joints, and the metacarpophalangeal joints were significantly affected more frequently in patients with RA than in patients with PsA (p < 0.05), whereas the proximal interphalangeal joints were significantly more frequently affected in patients with PsA (p < 0.05). CONCLUSION Periostitis and synovitis of the proximal interphalangeal joints are typical MRI findings in patients with PsA, whereas synovitis with erosions of the wrist, the midcarpal joints, the carpometacarpal joints, and the metacarpophalangeal joints are typical findings in patients with RA.
Collapse
|
14
|
Density histogram analysis of unenhanced hepatic computed tomography in patients with diffuse liver diseases. J Comput Assist Tomogr 2006; 30:201-5. [PMID: 16628032 DOI: 10.1097/00004728-200603000-00006] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVE The aim of the study was to assess the potential of density histogram analysis of unenhanced hepatic computed tomography (CT) in the diagnosis and differentiation of diffuse liver diseases. METHODS Twenty-six patients with normal liver parenchyma, 35 patients with diffuse steatosis, 14 patients with acute steatohepatitis, 15 patients with active alcoholic cirrhosis, 23 patients with inactive alcoholic cirrhosis, 15 patients with virus-induced cirrhosis, and 8 patients with hemochromatosis underwent unenhanced hepatic CT. All diffuse liver diseases and the absence of diffuse liver disease were histologically proven. Quantitative analysis of unenhanced liver parenchyma was performed in each patient. RESULTS The hepatic density histogram showed no significant differences in kurtosis and skewness between the groups (P > 0.05). Except for steatosis, active alcoholic cirrhosis, and hemochromatosis, diffuse liver diseases led to similar densities of liver parenchyma in unenhanced hepatic CT. CONCLUSION A reliable diagnosis and differentiation of diffuse liver diseases on the basis of density histogram analysis is not possible.
Collapse
|
15
|
Multiphasic multidetector-row CT (MDCT) in detection and staging of transitional cell carcinomas of the upper urinary tract. Eur Radiol 2006; 16:1244-52. [PMID: 16404565 DOI: 10.1007/s00330-005-0078-0] [Citation(s) in RCA: 85] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2005] [Revised: 10/05/2005] [Accepted: 11/04/2005] [Indexed: 01/02/2023]
Abstract
The aim of this study was to evaluate the potential of multiphasic multidetector-row CT (MDCT) in the detection and staging of transitional cell carcinomas (TCC) of the upper urinary tract. We performed a retrospective chart review of 39 consecutive patients with 41 histologically verified TCC of the renal pelvis and/or the ureter. The urinary tract was examined using MDCT performing unenhanced and contrast-enhanced scans during the corticomedullary (CMP), nephrographic (NP) and pyelographic phase (PP). Tumors were staged according to the TNM classification. MDCT and histopathological findings were correlated. The attenuation of the lesions was documented in Hounsfield units (HU). In MDCT, all 41 TCC--including two multicentric TCC--were detected. TCC confined to the organ (stage 0a-II) was correctly staged in 28/29 tumors (96.6%). Stage III-IV tumors were correctly staged in 8/12 patients (66.6%). Overall, MDCT was accurate in predicting pathologic TNM stage in 36/41 upper urinary tract TCC (87.8%). There was no significant difference of mean attenuation of TCC between CMP, NP and PP (P > 0.05). MDCT with its high spatial and temporal resolution is an accurate tool for detection TCC of the upper urinary tract, with 87.8% accuracy in predicting its stage.
Collapse
|
16
|
Abstract
OBJECTIVE The purpose of this study was to assess the influence of the iodine flow rate on parenchymal and vascular enhancement during multiphasic abdominal multidetector-row computed tomography (MDCT). METHODS Fifteen patients underwent MDCT at an iodine flow rate of 1.2 g/s as well as 1.6 g/s (group A, protocols 1 and 2), and 90 patients underwent MDCT at an iodine flow rate of 1.2 g/s (group B) or 1.6 g/s (group C). Measurements were performed for all groups in the liver, spleen, pancreas, portal vein, inferior vena cava, and abdominal aorta. RESULTS Aortal and pancreatic enhancement during the arterial phase was significantly higher with the higher iodine flow rate. The mean difference in aortal enhancement was 60 Hounsfield units (HU) between protocols 1 and 2 of group A, and the mean difference was 70 HU between groups B and C. The mean difference in pancreatic enhancement was 10 HU between protocols 1 and 2 of group A and 17 HU between groups B and C. During the portal and hepatic venous phases, no significant difference in enhancement was observed. CONCLUSION A high iodine flow rate in multiphasic abdominal MDCT improves enhancement of the aorta and the pancreas during the arterial phase but does not influence later phases.
Collapse
|
17
|
[Three-dimensional ultrasound (3DUS) of the neonatal brain: clinical application in patients of the neonatal intensive care unit (NICU)]. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2005; 26:299-306. [PMID: 16123924 DOI: 10.1055/s-2005-858360] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
AIM To prospectively evaluate the potential role of 3DUS of the neonatal brain. METHOD 60 patients from the NICU (gestational age: 25-42 weeks, mean: 31.6 weeks, age: 0 to 90 days, median: 10 days) underwent 2D- and 3D-neurosonography. Both studies were evaluated independently by two observers for comparison. Inter- and intraobserver variability were calculated. RESULTS All 3DUS were of diagnostic quality and could be performed without sedation. 3DUS missed no essential diagnosis as established by conventional ultrasound (2DUS). Diagnosis included normal or physiologically immature neonatal brains (n = 21), plexus cysts (n = 4), plexus bleedings (n = 10), intraventricular haemorrhages grade I-III (n = 8), periventricular pathology such as periventricular echodensities (n = 4) and periventricular haemorrhages or cerebral infarctions (n = 6), hydrocephalus (n = 4), widened subdural spaces (n = 2) and one suprasellar midline tumour. 3DUS imaging time at the patient (4.8 +/- 2.6 min) was significantly shorter than for 2DUS (9.1 +/- 6.1 min). The additional axial plane provided by 3DUS improved the sonographic potential for differential diagnosis. 3DUS allowed an improved standardisation and documentation potentially valuable for follow-up. No statistically significant differences in intra- and interobserver variability were noted compared to 2DUS. Restrictions of 3DUS were the lack of directional Doppler data and the lower resolution particularly of the purely reconstructed plane. CONCLUSION Bedside neonatal 3D-neurosonography at the NICU is feasible with diagnostic quality without sedation. 3DUS improves comparison during follow-up, as well as standardisation and documentation, and can be considered a useful adjunct in neonatal 2D-neurosonography.
Collapse
|
18
|
MDCT angiography of the pulmonary arteries: influence of iodine flow concentration on vessel attenuation and visualization. AJR Am J Roentgenol 2005; 184:1935-9. [PMID: 15908557 DOI: 10.2214/ajr.184.6.01841935] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE Our objective was to assess the influence of iodine flow concentration on attenuation and visualization of the pulmonary arteries in thoracic MDCT angiography. MATERIALS AND METHODS One hundred consecutive patients who were referred to our department with suspected acute pulmonary embolism underwent MDCT angiography of the pulmonary arteries either with 120 mL of standard contrast medium (300 mg I/mL) (group A) or with 90 mL of high-concentration contrast medium (400 mg I/mL) (group B). The contrast medium was injected at a flow rate of 4 mL/sec. The scan delay was determined using a semiautomatic bolus-tracking system in all examinations conducted with the same scanning parameters. Quantitative analysis was performed by region-of-interest measurements along the z-axis to compare the attenuation profiles of the two groups. Attenuation of the fourth-, fifth-, and sixth-order arteries was assessed visually for differences between the two groups. RESULTS The mean enhancement along the z-axis was 268 +/- 56 H in group A and 344 +/- 108 in group B. The difference of 76 H was statistically significant (p < 0.001). The attenuation profile was similar in both groups. The detection rate of fifth- and sixth-order arteries was significantly higher in group B than in group A (94% compared with 91% and 72% compared with 60%, respectively, p < 0.01). CONCLUSION Use of a high flow concentration of iodine in MDCT angiography of the pulmonary arteries significantly increases attenuation of the pulmonary arteries, thereby improving visualization of subsegmental pulmonary arteries.
Collapse
|
19
|
Mehrdetektoren CT-Angiographie der Pulmonalarterien: Einfluss des Jodflusses auf die Kontrastierung und die Detektierbarkeit. ROFO-FORTSCHR RONTG 2005. [DOI: 10.1055/s-2005-867498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
20
|
Frequency and Significance of Lumbar and Inferior Mesenteric Artery Perfusion After Endovascular Repair of Abdominal Aortic Aneurysms. J Endovasc Ther 2004; 11:649-58. [PMID: 15615556 DOI: 10.1583/04-1248mr.1] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
PURPOSE To evaluate the frequency and influence of perfused side branches (lumbar arteries [LA] and inferior mesenteric artery trunks) on development of type II endoleaks (EL-II) and on volume changes of abdominal aortic aneurysms (AAA) after endovascular repair. METHODS Of 114 patients undergoing EVR of AAA, 89 patients (83 men; mean age 72+/-7.5 years, range 51-88) with >6 months' follow-up and no type I endoleaks were retrospectively analyzed to determine any relationships between retrograde perfusion, endoleaks, and sac volume. Data were derived from computed tomographic angiographic (CTA) scans taken before and after intervention, at discharge, and at 1, 3, 6, and semi-annually thereafter in follow-up. Two groups were identified and compared based on their status at 6 months post EVR: without perfused side branches (group 1) and with perfused collaterals (group 2); group 2 was further divided according to the absence (2a) or presence (2b) of endoleak. RESULTS Median follow-up was 24 months (range 6-36). Based on a total of 582 CTAs analyzed, 17 (19%) patients developed type II endoleaks (EL-II) during follow-up. There was a significant difference in the number of perfused LAs prior to EVR between groups 1 (n=44) and the 45 patients with postprocedural patent collateral arteries in group 2 (p<0.05); there was no significant difference between groups 2a and 2b (p=0.88) relative to the number of pre-existing patent collaterals. The number of pLAs preoperatively and the rate of type II endoleak were significantly correlated (p<0.05). No type II endoleak was seen in patients without perfused side branches (p=0.01). No significant differences in mean volumes were found between groups 1 and 2a (no EL-II), but significant differences between groups 1 and 2b were seen in later follow-up. CONCLUSIONS A larger number of patent LAs before EVR was associated with a significantly higher rate of type II endoleak. Patent collateral vessels were common after aneurysm repair, but the frequency decreased during follow-up. Persistent side branch perfusion was associated with increased type II endoleak after endovascular AAA repair. Significant differences in volume changes in later follow-up were seen between patients with or without type II endoleak.
Collapse
|
21
|
Aortoiliac enhancement during computed tomography angiography with reduced contrast material dose and saline solution flush: influence on magnitude and uniformity of the contrast column. Invest Radiol 2004; 39:20-6. [PMID: 14701985 DOI: 10.1097/01.rli.0000091841.45342.84] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
RATIONALE AND OBJECTIVES To compare the magnitude and uniformity of aortoiliac contrast enhancement obtained from uniphasic contrast material injections versus contrast material injections with reduced iodine dose followed by a saline flush in aortoiliac multislice CT angiography (CTA). METHODS Twenty-nine patients with abdominal aortic aneurysms underwent aortoiliac CTA using protocols A and B. With protocol A, 120 mL contrast material (300 mgI/mL), and with protocol B, 100 mL contrast material followed by a 40-mL saline solution flush were administered at a flow rate of 4 mL/s. Quantitative analysis was performed by calculating mean aortoiliac attenuation, mean plateau deviation, and mean difference between maximum and minimum attenuation value for both groups. Qualitative analysis was performed by visual assessment of vascular enhancement using 2-dimensional and 3-dimensional postprocessing techniques. RESULTS The mean aortoiliac attenuation with protocol A was 291 +/- 62 HU, and with protocol B it was 285 +/- 61 HU. The difference of 6 HU was not statistically significant (P = 0.27). Mean plateau deviation was significantly smaller using protocol A than protocol B (16 +/- 9 HU vs. 20 +/- 10 HU, P = 0.03). In addition, the mean difference between maximum and minimum attenuation value was significantly smaller with protocol A than with protocol B (59 +/- 29 HU vs. 72 +/- 32 HU, P = 0.01). Visual analysis showed no difference in contrast material magnitude and homogeneity between the protocols. CONCLUSIONS In aortoiliac CTA, a saline solution flush after contrast material bolus allows an iodine dose reduction of approximately 20 mL without impairing the magnitude of contrast enhancement but degrades the uniformity of the contrast column. However, the degradation does not affect visual analysis.
Collapse
|
22
|
Einfluss von CT-Gerät und Untersucher auf Volumsmessungen: Eine Phantomstudie in Bezug auf die Anwendung in der CT-Angiographie Kontrolle von abdominalen Aortenaneurysmen nach endovaskulärer Therapie. ROFO-FORTSCHR RONTG 2004. [DOI: 10.1055/s-2004-828008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
23
|
Abdominal multidetector row computed tomography: reduction of cost and contrast material dose using saline flush. J Comput Assist Tomogr 2003; 27:847-53. [PMID: 14600448 DOI: 10.1097/00004728-200311000-00002] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To evaluate the potential of a saline solution flush after the contrast material bolus in abdominal multidetector row CT (MDCT) in contrast material dose and cost reduction. METHODS Abdominal MDCT was performed in 78 patients who were assigned randomly to 2 groups receiving 120 mL nonionic contrast material (300 mgI/mL) alone or 100 mL of the same contrast material pushed with 40 mL of saline solution. Mean attenuation values for both groups were measured in the liver, the spleen, the pancreas, the portal vein, the inferior vena cava, and the abdominal aorta. Cost analyses were performed for both groups. RESULTS There was no significant difference in parenchymal and vascular enhancement between both groups. The difference of the enhancement was 2 HU for the liver (P = 0.11), 2 HU for the spleen (P = 0.44), 3 HU for the pancreas (P = 0.38), 9 HU for the portal vein (P = 0.11), 3 HU for the inferior vena cava (P = 0.55), and 10 HU for the aorta (P = 0.06). Taking the costs of contrast material, saline solution, and disposal material into account, 7.30 dollars was saved by the patient using a saline solution flush. CONCLUSIONS Using a saline flush after the contrast material bolus in abdominal MDCT allows an iodine dose reduction of approximately 6 g, or 17%, without impairing mean parenchymal and vascular enhancement and a cost reduction of 7.30 dollars per patient.
Collapse
|
24
|
Value of a blood pool contrast agent in MR venography of the lower extremities and pelvis: Preliminary results in 12 patients. Magn Reson Med 2003; 50:993-1002. [PMID: 14587010 DOI: 10.1002/mrm.10607] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The purpose of this study was to determine the value of a blood-pool contrast media (NC100150, Nycomed Imaging (now Amersham Health) Oslo, Norway) for evaluation of venous thrombosis of the deep veins of the pelvis and lower extremities. Twelve patients were prospectively evaluated with conventional X-ray venography (XRV) and MR venography (MRV) after injection of NC100150 (2 ml/kg body weight). The source images and 3D maximum intensity projection (MIP) were viewed on an independent workstation. Diagnosis was made in consensus from two radiologists. Diagnostic image quality was achieved in 87 veins with XRV and MRV. As determined by XRV, thrombus was present in 30 out of 87 veins (34.5%). There was agreement concerning absence or presence of thrombi in 83 out of 87 veins (95.4%; kappa = 0.9 +/- 0.05). Compared to XRV, overall sensitivity and specificity of blood-pool MRV were 93.3% and 96.5%, respectively. Two venous thromboses of the popliteal and posterior tibial vein were diagnosed in MRV, but not in XRV. Conversely, two venous thromboses below the knee had been missed by MRV. NC100150 allows prolonged and improved visualization of the peripheral vasculature and may overcome some limitations of gadolinium contrast media. A more complete examination of the proximal venous tree may be possible than with conventional XRV. Arterial and venous enhancement and motion artifacts can limit image interpretation.
Collapse
|
25
|
Improvement of parenchymal and vascular enhancement using saline flush and power injection for multiple-detector-row abdominal CT. Eur Radiol 2003; 14:659-64. [PMID: 14566425 DOI: 10.1007/s00330-003-2085-3] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2002] [Revised: 04/17/2003] [Accepted: 09/01/2003] [Indexed: 12/11/2022]
Abstract
The aim of this study was to determine if a saline solution flush following low dose contrast material bolus improves parenchymal and vascular enhancement during abdominal multiple detector-row computed tomography (MDCT). Forty-one patients (24 men and 17 women; mean age 49 years, age range 27-86 years) underwent abdominal MDCT (collimation 4x5 mm, 15-mm table increment, reconstruction interval 5 mm, gantry rotation period 0.8 s) with a single- as well as with a double syringe power injector. Indication for examination were benign and malignant tumors and inflammatory diseases. Patients received 100 ml nonionic contrast material (300 mgI/ml) alone or pushed with 20 ml saline solution. Mean enhancement values for both protocols were measured in the liver, the spleen, the pancreas, the renal cortex, the portal vein, the inferior vena cava and the abdominal aorta. Double syringe power-injector protocol led to significantly higher parenchymal and vascular enhancement than single syringe power-injector protocol (p<0.05). The improvement in mean enhancement of the liver was 9 +/- 9 HU, of the spleen 8 +/- 10 HU, of the pancreas 7 +/- 9 HU, and of the renal cortex 8 +/- 20 HU. The improvement in mean enhancement of the portal vein was 10 +/- 17 HU of the inferior vena cava 8 +/- 13 HU and of the abdominal aorta 10 +/- 17 HU. The use of a double syringe power injector with saline flush following contrast material bolus significantly improves parenchymal and vascular enhancement during contrast-enhanced abdominal MDCT with low iodine doses.
Collapse
|
26
|
Abstract
OBJECTIVES To determine whether the use of more elaborate diagnostic tests can identify possible risk factors for secondary osteoporosis and to evaluate the impact of these possible risk factors on the severity of bone disease in the study population. DESIGN Cross-sectional study. SETTING AND PARTICIPANTS We have investigated 377 subjects (285 females, 92 males) with osteoporosis (T-score less than -2.5 in dual energy X-ray absorption) or nontraumatic lumbar vertebral fractures; these patients were referred to our hospital, a secondary care centre, for evaluation and treatment of osteoporosis. RESULTS Osteoporosis without attributable risk factor was diagnosed in 106 women (37%) and 30 men (33%). In 241 patients (179 women, 62 men) one or more possible risk factors for osteoporosis (in this paper also called subclinical disease) were revealed. The most common were lactose malabsorption, disturbed exocrine pancreatic function and renal tubular disturbances, including renal hypercalciuria, incomplete renal tubular acidosis and mild phosphate diabetes. The number of possible risk factors in the individual patient was significantly related to the severity of osteoporosis as assessed by Z-scores (Spearman correlation r = -0.43, P < 0.001, n = 172 for females; r = -0.28, P < 0.05, n = 65 for males). CONCLUSIONS All the identified subclinical diseases would have remained undetected if the currently accepted guidelines for the investigation of patients with osteoporosis were applied. The statistically significant correlation between the number of identified possible risk factors and the severity of bone disease in the individual patient strongly suggests the pathogenetic significance of the identified subclinical diseases. It is yet to be shown, whether specific treatment of these subclinical diseases yields additional improvement of bone mass as compared with standard treatment of osteoporosis.
Collapse
|
27
|
Abstract
PURPOSE To assess the efficacy and safety of the Rotarex rotational thrombectomy catheter in treating occlusions of the femoropopliteal arteries. METHODS The Rotarex catheter (Straub Medical, Switzerland) is a rotational thrombectomy device which is supposed to be able to remove fresh and partially organized clot material from an acutely or subacutely occluded vessel. Nineteen limbs of 18 patients (10 women, 8 men; mean age 72.9 +/- 7.3 years) with acute or subacute (23 +/- 16 days) occlusions of the middle or distal third of the superficial femoral artery or the popliteal artery were treated. The occlusions were 3-20 cm long. RESULTS Thrombectomy was technically successful in 15 of 19 vessels (79%). The primary procedural success including additional procedures such as angioplasty and/or stent-graft placement in 17 limbs was 94%. The mean ankle-brachial index improved from 0.36 +/- 0.26 (before thrombectomy) to 0.81 +/- 0.21 (2 days after the procedure) (p = 0.012). Clinical symptoms shifted to at least one Fontaine stage lower in 13 limbs. As complications we observed two perforations (arteries showing heavily calcified plaques), one arteriovenous fistula and three distal embolizations. One perforation, the fistula and one intimal tear after percutaneous transluminal angioplasty were treated with covered stents; the three distal embolizations were treated successfully with aspiration or Rotarex thrombectomy. In the other perforation the intervention was terminated. None of the complications needed surgical treatment. The complication rate was 31.5%. Follow-up studies showed three early (4-11 days) and six late (1-6 months) reocclusions. The cumulative primary patency rate was 68 +/- 12% at 3 months, and 39 +/- 13% at 6, 12 and 19 months; the secondary patency rate was 68 +/- 12% at 3 months and 53 +/- 13% at 6, 12 and 20 months. CONCLUSION The Rotarex thrombectomy catheter is effective and quick in treating acute and subacute occlusions of the superficial femoral and popliteal arteries. It should not be used in arteries with heavily calcified plaques because of the risk of perforation. Limited long-term patency is mainly due to the complexity of the underlying lesion. Our results suggest that the Rotarex mechanical thrombectomy catheter is effective and might serve as an alternative treatment modality to intra-arterial lysis.
Collapse
|
28
|
Placement of Hemobahn stent-grafts in femoropopliteal arteries: early experience and midterm results in 18 patients. J Vasc Interv Radiol 2001; 12:943-50. [PMID: 11487674 DOI: 10.1016/s1051-0443(07)61574-7] [Citation(s) in RCA: 60] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
PURPOSE To determine the outcome of a new polytetrafluoroethylene (PTFE)-covered stent-graft in the treatment of occlusive lesions of the femoropopliteal arteries. MATERIALS AND METHODS Eighteen patients with intermittent claudication (Fontaine stages IIb-IV; Rutherford classes I/2-III/5) and occlusive lesions of the superficial femoral and/or popliteal artery were treated with use of a new PTFE-covered stent-graft (Hemobahn). Indication for stent-graft insertion was an unsatisfactory result after balloon dilation. RESULTS Successful stent-graft placement was achieved in 17 patients (94%). In one patient, additional insertion of a Palmaz stent was necessary because of a stent-graft wrinkle. Mean ankle-brachial index increased from 0.72 +/- 0.15 preoperatively to 0.94 +/- 0.17 postoperatively (P =.028). Fifteen patients (83%) experienced an initial improvement of at least one clinical stage. Primary patency was 61% +/- 11% at 3 months and 49% +/- 12% at 6 months. Stent-graft occlusion was observed in 13 patients (72%). In four patients, the stent-graft was reopened percutaneously by balloon angioplasty (n = 2) and/or rotational thrombectomy (n = 2). Therefore, the secondary patency rate was 67% +/- 11% at 3 months and 61% +/- 11% at 6 months. Patency rates proved to be significantly lower for stent-grafts longer than 10 cm (P =.03). Intimal hyperplasia at the proximal or distal end of the stent-graft was observed in seven patients (39%). Complications such as access site hematoma (n = 3), distal thromboembolism (n = 2), and abscess formation around the stent-graft (n = 1) were observed. CONCLUSION Despite excellent initial angiographic results, the patency rate in lesions treated with the Hemobahn stent-graft in this small study was unsatisfactory. Use of stent-grafts longer than 10 cm and the occurrence of intimal hyperplasia proved to be major factors in the reduction of long-term patency rates.
Collapse
|
29
|
Abstract
In this review the technical and systemic complications occurring during endoluminal repair of abdominal aortic aneurysms are summarized. According to the data in the literature the technical success-rate of the endoluminal procedure should be >90% and the overall complication-rate <10%. It should be differentiated between complications which have an adverse effect on the outcome of the procedure, and technical problems, which complicate the procedure but do not affect the outcome. The majority of the technical problems can be solved endoluminally. The 30-day mortality rate should be in the same range as elective open surgical repair. One major factor influencing the immediate results is the experience of the interventional team.
Collapse
|