Electrocardiographic predictors of atrial mechanical sensing in leadless pacemakers. Heart Rhythm 2024:S1547-5271(24)00233-9. [PMID: 38432424 DOI: 10.1016/j.hrthm.2024.02.061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 02/26/2024] [Accepted: 02/28/2024] [Indexed: 03/05/2024]
Abstract
BACKGROUND Leadless pacemakers (LPs) capable of VDD pacing allow for atrioventricular synchrony through mechanical sensing of atrial contraction. However, mechanical sensing is less reliable and less predictable than electrical sensing. OBJECTIVE The purpose of this study was to evaluate P-wave amplitude during sinus rhythm from preoperative 12-lead electrocardiograms (ECGs) as a predictor for atrial mechanical sensing in patients undergoing VDD LP implantation. METHODS Consecutive patients undergoing VDD LP implantation were included in this 2-center prospective cohort study. ECG parameters were evaluated separately and in combination for association with the signal amplitude of atrial mechanical contraction (A4). RESULTS Eighty patients (median age 82 years; female 55%; mean body mass index [BMI] 25.8 kg/m2) were included in the study and 61 patients in the A4 signal analysis (19 patients in VVI mode during follow-up). Absolute (aVL, aVF, V1, V2) and BMI-adjusted (I, II, aVL, aVF, aVR, V1, V2) P-wave amplitudes from baseline ECGs demonstrated a statistically significant positive correlation with A4 signal amplitude (all P <.05). A combined P-wave signal amplitude of at least 0.2 mV in V1 and aVL was predictive, with specificity of 83% (95% confidence interval 67%-100%) for A4 signal ≥1 m/s2. We found a significant correlation of A4 signal amplitude and overall atrioventricular synchrony (P = .013). CONCLUSION P-wave amplitudes in ECG leads aVL and V1 can predict A4 signal amplitude in patients with VDD LP and therefore the probability of successful AV synchronous pacing.
Collapse
|
2
|
Life cycle and post-mortem ingrowth patterns of a leadless pacemaker system. Europace 2024; 26:euae013. [PMID: 38242703 PMCID: PMC10869213 DOI: 10.1093/europace/euae013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2023] [Accepted: 01/08/2024] [Indexed: 01/21/2024] Open
|
3
|
Elevated systolic pulmonary artery pressure is a substantial predictor of increased mortality after transcatheter aortic valve replacement in males, not in females. Clin Res Cardiol 2024; 113:138-155. [PMID: 37750991 PMCID: PMC10808322 DOI: 10.1007/s00392-023-02307-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2023] [Accepted: 09/05/2023] [Indexed: 09/27/2023]
Abstract
BACKGROUND While pulmonary hypertension (PH) in patients with severe aortic valve stenosis (AS) is associated with increased mortality after transcatheter aortic valve replacement (TAVR), there is limited data on gender differences in the effects on long-term survival. OBJECTIVE The aim of this retrospective, multicenter study was to investigate the prognostic impact of pre-interventional PH on survival of TAVR patients with respect to gender. METHODS 303 patients undergoing TAVR underwent echocardiography to detect PH prior to TAVR via measurement of systolic pulmonary artery pressure (sPAP). Different cut-off values were set for the presence of PH. The primary endpoint was all-cause mortality at 1, 3 and 5 years. RESULTS Kaplan-Meier analysis by gender showed that only males exhibited significant increased mortality at elevated sPAP values during the entire follow-up period of 5 years (sPAP ≥ 40 mmHg: p ≤ 0.001 and sPAP ≥ 50 mmHg: p ≤ 0.001 in 1- to 5-year survival), whereas high sPAP values had no effect on survival in females. In Cox regression analysis based on the selected sPAP thresholds, male gender was an independent risk factor for long-term mortality after TAVR in all time courses. CONCLUSION Male gender was an isolated risk factor for premature death after TAVR in patients with echocardiographic evidence of PH and severe AS. This could mean that, the indication for TAVR should be discussed more critically in men with severe AS and an elevated sPAP, while in females, PH should not be an exclusion criterion for TAVR.
Collapse
|
4
|
Main pulmonary artery diameter in combination with cardiovascular biomarkers: new possibilities to identify pulmonary hypertension in patients with severe aortic valve stenosis. Minerva Med 2023; 114:802-814. [PMID: 35822856 DOI: 10.23736/s0026-4806.22.08167-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2024]
Abstract
BACKGROUND Echocardiography is currently the noninvasive method of choice to screen patients with severe aortic valve stenosis (AS) for pulmonary hypertension (PH) by estimating systolic pulmonary artery pressure (sPAP). However, radiological options are also available by determining the main pulmonary artery (MPA) diameter in the setting of CT angiography. The aim of the present study was to compare cardiovascular biomarkers with the MPA diameter to allow other ways of detecting PH in patients with severe AS. METHODS One hundred ninety-four patients with severe AS undergoing transcatheter aortic valve replacement (TAVR) were included in this study and were divided into two groups based on the CT-angiographically determined MPA diameter. In accordance with ESC guidelines, a cut-off value of 29 mm was determined in this study, with the absence of PH defined by an MPA diameter <29 mm (N79/194) and the presence of PH defined by an MPA diameter ≥29 mm (115/194). Immediately before interventional aortic valve replacement, blood samples were drawn from the subjects and relevant cardiovascular biomarkers such as BNP, cTnI, GDF-15, H-FABP, IGF-BP2 and suPAR were assessed. RESULTS Patients with an MPA diameter ≥29 mm had significantly higher BNP (P=0.004), cTnI (P=0.039) and H-FABP (P=0.015) plasma levels, whereas GDF-15 (P=0.140), IGF-BP2 (P=0.088) and suPAR (P=0.140) showed no significant differences. In addition, cut-off values were calculated to predict an MPA diameter ≥29 mm. Significant results were shown with 1634.00 pg/mL for BNP (P=0.004), with 16.50 pg/mL for cTnI (P=0.039) and with 1.16 ng/mL for H-FABP (P=0.016). In a combined biomarker analysis, the 2-way combination of BNP and IGF-BP2 (AUC 0.671; 95%CI 0.538-0.805; P=0.023) and the 3-way combination of BNP, H-FABP and IGF-BP2 (AUC 0.685; 95%CI 0.551-0.818; P=0.015) showed the best results. Biomarker follow-up at 3 and 12 months after TAVR did not require additional information gain. Regarding 1-year survival, no significant difference could be detected between patients with an MPA diameter<29 mm compared to patients with ≥29 mm (log-rank test: P=0.262). CONCLUSIONS The MPA diameter remains a controversial parameter for the detection of PH in patients with severe AS. Standing on its own, this non-invasive parameter may not be precise enough to detect PH accurately. Combining this parameter with several biomarkers did not provide significant additional information.
Collapse
|
5
|
[Leadless pacemakers : A "permanently" good solution?]. Herzschrittmacherther Elektrophysiol 2023; 34:272-277. [PMID: 37870606 PMCID: PMC10682231 DOI: 10.1007/s00399-023-00970-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2023] [Accepted: 09/25/2023] [Indexed: 10/24/2023]
Abstract
The two currently available leadless pacemakers are highly effective and safe in the respective approval studies and also real-world registries. Compared to conventional pacemakers, there are lower long-term complication rates compared to conventional pacemaker systems (especially regarding lead dislocations and systemic infections). Increasing evidence (currently largely for the Micra™ [Medtronic, Minneapolis, MN, USA] device) shows that these advantages are also valid in the long-term. Leadless pacemakers can therefore be regarded a "permanently good solution", when appropriately implanted in suitable patients.
Collapse
|
6
|
CT measured pulmonary artery to ascending aorta ratio stratified by echocardiographically obtained systolic pulmonary artery pressure values for noninvasive detection of pulmonary hypertension in patients with severe aortic valve stenosis. Clin Res Cardiol 2023; 112:1394-1416. [PMID: 36935421 PMCID: PMC10562282 DOI: 10.1007/s00392-023-02182-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 03/10/2023] [Indexed: 03/21/2023]
Abstract
BACKGROUND Transthoracic echocardiography (TTE) offers a measurement method for the determination of pulmonary hypertension (PH) in patients with severe aortic valve stenosis (AS) with determination of maximal tricuspid regurgitation velocity (TRVmax) and systolic pulmonary artery pressure (sPAP). Radiological parameters for noninvasive detection of PH, most importantly computed tomography (CT) based PA/AA-ratio = ratio of pulmonary artery diameter (PA) and ascending aorta diameter (AA), are also included in the latest ESC guidelines. The aim of the present study was to define cut-off values for PA/AA-ratio taking also into account cardiovascular biomarkers to determine criteria for noninvasive diagnosis of PH. METHODS 194 patients with severe AS undergoing transcatheter aortic valve replacement (TAVR) underwent pre-procedural TTE and CT with measurement of PA/AA-ratio. Additionally, common cardiovascular biomarkers were determined. RESULTS TAVR patients with an sPAP ≥ 40 mmHg or a TRVmax ≥ 2.9 m/s had a PA/AA-ratio ≥ 0.80 in an AUROC analysis. The cut-off value of ≥ 0.80 resulted in a significantly higher mortality rate (log-rank test: p = 0.034) in these patients in a Kaplan-Meier analysis regarding 1-year survival after TAVR. Significant differences in biomarker expression between patients with a PA/AA-ratio ≥ 0.80 or < 0.80 occurred for BNP (p = 0.001), cTnI (p = 0.032), GDF-15 (p = 0.002) and H-FABP (p = 0.015). CONCLUSION PA/AA-ratio ≥ 0.80 is a promising radiological parameter that can provide information about mortality in patients with severe AS undergoing TAVR; combined with biomarkers it may contribute to noninvasive detection of PH in patients with severe AS.
Collapse
|
7
|
ECG Electrode Localization: 3D DS Camera System for Use in Diverse Clinical Environments. SENSORS (BASEL, SWITZERLAND) 2023; 23:5552. [PMID: 37420719 DOI: 10.3390/s23125552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 05/15/2023] [Accepted: 06/08/2023] [Indexed: 07/09/2023]
Abstract
Models of the human body representing digital twins of patients have attracted increasing interest in clinical research for the delivery of personalized diagnoses and treatments to patients. For example, noninvasive cardiac imaging models are used to localize the origin of cardiac arrhythmias and myocardial infarctions. The precise knowledge of a few hundred electrocardiogram (ECG) electrode positions is essential for their diagnostic value. Smaller positional errors are obtained when extracting the sensor positions, along with the anatomical information, for example, from X-ray Computed Tomography (CT) slices. Alternatively, the amount of ionizing radiation the patient is exposed to can be reduced by manually pointing a magnetic digitizer probe one by one to each sensor. An experienced user requires at least 15 min. to perform a precise measurement. Therefore, a 3D depth-sensing camera system was developed that can be operated under adverse lighting conditions and limited space, as encountered in clinical settings. The camera was used to record the positions of 67 electrodes attached to a patient's chest. These deviate, on average, by 2.0 mm ±1.5 mm from manually placed markers on the individual 3D views. This demonstrates that the system provides reasonable positional precision even when operated within clinical environments.
Collapse
|
8
|
Impact of pacing mode and different echocardiographic parameters on cardiac output (PADIAC). Front Cardiovasc Med 2023; 10:1185518. [PMID: 37265566 PMCID: PMC10231674 DOI: 10.3389/fcvm.2023.1185518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Accepted: 04/27/2023] [Indexed: 06/03/2023] Open
Abstract
Introduction The extent of the hemodynamic benefit from AV-synchronous pacing in patients with sinus rhythm and AV block is not completely understood. Thus, we systematically investigated the association of an array of echocardiographic and epidemiological parameters with the change in cardiac output depending on the stimulation mode (AV-synchronous or AV-asynchronous pacing). Methods Patients in sinus rhythm after previous dual chamber pacemaker implantation underwent a thorough basic echocardiographic assessment of diastolic and systolic left ventricular function, and atrial function (26 echo parameters, including novel speckle tracking strain measurements). Then, stroke volume was measured with AV-synchronous (DDD) and AV-asynchronous (VVI) pacing. Each patient represented their own control, and the sequence of stroke volume measurements was randomized. Results In this prospective single-center study (NCT04068233, registration August 22nd 2019), we recruited 40 individuals. The stroke volume was higher in all patients when applying AV-synchronous DDD pacing [median increase 12.8 ml (16.9%), P < 0.001]. No echo parameter under investigation was associated with the extent of stroke volume increase in a linear regression model. Of all epidemiological variables, a history of acute myocardial infarction (AMI) was associated with an attenuated stroke volume gain in a univariate and a multivariate regression model that adjusted for confounders. A- and S-wave velocities were reduced in the AMI group. Discussion In our cohort of patients, each subject benefited from AV-synchronous DDD pacing. No single echo parameter could predict the amount of stroke volume increase. The beneficial effect of AV-synchronous pacing on stroke volume was attenuated after prior acute myocardial infarction.ClinicalTrials.gov identifier (NCT number): NCT04068233.
Collapse
|
9
|
A worldwide survey on incidence, management and prognosis of oesophageal fistula formation following atrial fibrillation catheter ablation: The POTTER-AF study. Eur Heart J 2023:7123667. [PMID: 37062040 DOI: 10.1093/eurheartj/ehad250] [Citation(s) in RCA: 32] [Impact Index Per Article: 32.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 03/25/2023] [Accepted: 04/14/2023] [Indexed: 04/17/2023] Open
Abstract
AIMS Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management and outcome are sparse. METHODS AND RESULTS This international multicenter registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553,729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed at 214 centers in 35 countries. In 78 centers 138 patients (0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (p<0.0001)) were diagnosed with an oesophageal fistula. Periprocedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8%, and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) (odds ratio 7.463 (2.414, 23.072) p<0.001). CONCLUSIONS Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high.
Collapse
|
10
|
The Presence of Ascending Aortic Dilatation in Patients Undergoing Transcatheter Aortic Valve Replacement Is Negatively Correlated with the Presence of Diabetes Mellitus and Does Not Impair Post-Procedural Outcomes. Diagnostics (Basel) 2023; 13:diagnostics13030358. [PMID: 36766463 PMCID: PMC9914357 DOI: 10.3390/diagnostics13030358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 01/13/2023] [Accepted: 01/16/2023] [Indexed: 01/21/2023] Open
Abstract
Both relevant aortic valve stenosis (AS) and aortic valve insufficiency significantly contribute to structural changes in the ascending aorta (AA) and thus to its dilatation. In patients with severe AS undergoing transcatheter aortic valve replacement (TAVR), survival data regarding aortic changes and laboratory biomarker analyses are scarce. METHODS A total of 179 patients with severe AS and an available computed tomography were included in this retrospective study. AA was measured, and dilatation was defined as a diameter ≥ 40 mm. Thirty-two patients had dilatation of the AA. A further 32 patients from the present population with a normal AA were matched to the aortic dilatation group with respect to gender, age, body mass index and body surface area, and the resulting study groups were compared with each other. In addition to echocardiographic and clinical characteristics, the expression of cardiovascular biomarkers such as brain natriuretic peptide (BNP), soluble suppression of tumorigenicity-2 (sST2), growth/differentiation of factor-15 (GDF-15), heart-type fatty-acid binding protein (H-FABP), insulin-like growth factor binding protein 2 (IGF-BP2) and soluble urokinase-type plasminogen activator receptor (suPAR) was analyzed. Kaplan-Meier curves for short- and long-term survival were obtained, and Pearson's and Spearman's correlations were calculated to identify the predictors between the diameter of the AA and clinical parameters. RESULTS A total of 19% of the total cohort had dilatation of the AA. The study group with an AA diameter ≥ 40 mm showed a significantly low comorbidity with respect to diabetes mellitus in contrast to the comparison cohort with an AA diameter < 40 mm (p = 0.010). This result continued in the correlation analyses performed, as the presence of diabetes mellitus correlated negatively not only with the diameter of the AA (r = -0.404; p = 0.001) but also with the presence of aortic dilatation (r = -0.320; p = 0.010). In addition, the presence of AA dilatation after TAVR was shown to have no differences in terms of patient survival at 1, 3 and 5 years. There were no relevant differences in the cardiovascular biomarkers studied between the patients with dilated and normal AAs. CONCLUSION The presence of AA dilatation before successful TAVR was not associated with a survival disadvantage at the respective follow-up intervals of 1, 3 and 5 years. Diabetes mellitus in general seemed to have a protective effect against the development of AA dilatation or aneurysm in patients with severe AS.
Collapse
|
11
|
A Story of PA/BSA and Biomarkers to Diagnose Pulmonary Hypertension in Patients with Severe Aortic Valve Stenosis-The Rise of IGF-BP2 and GDF-15. J Cardiovasc Dev Dis 2023; 10:jcdd10010022. [PMID: 36661917 PMCID: PMC9864369 DOI: 10.3390/jcdd10010022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 12/30/2022] [Accepted: 01/02/2023] [Indexed: 01/09/2023] Open
Abstract
(1) Background: Currently, echocardiography is the primary non-invasive diagnostic method used to screen patients with severe aortic valve stenosis (AS) for pulmonary hypertension (PH) by estimating systolic pulmonary artery pressure (sPAP). Other radiological methods have been a focus of research in the past couple of years, as it was shown that by determining the pulmonary artery (PA) diameter, prognostic statements concerning overall mortality could be made in these patients. This study compared established and novel cardiovascular biomarkers with the PA/BSA value to detect PH in patients with severe AS. (2) Methods: The study cohort comprised 188 patients with severe AS undergoing transcatheter aortic valve replacement (TAVR), who were then divided into two groups based on PA/BSA values obtained through CT-angiography. The presence of PH was defined as a PA/BSA ≥ 16.6 mm/m2 (n = 81), and absence as a PA/BSA < 16.6 mm/m2 (n = 107). Blood samples were taken before TAVR to assess cardiovascular biomarkers used in this study, namely brain natriuretic peptide (BNP), cardiac troponin I (cTnI), high-sensitive troponin (hsTN), soluble suppression of tumorigenesis-2 (sST2), growth/differentiation factor 15 (GDF-15), heart-type fatty acid-binding protein (H-FABP), insulin-like growth factor binding protein 2 (IGF-BP2), and soluble urokinase-type plasminogen activator receptor (suPAR). (3) Results: Patients with a PA/BSA ≥ 16.6 mm/m2 showed significantly higher levels of BNP (p = <0.001), GDF-15 (p = 0.040), and H-FABP (p = 0.007). The other investigated cardiovascular biomarkers did not significantly differ between the two groups. To predict a PA/BSA ≥ 16.6 mm/m2, cut-off values for the biomarkers were calculated. Here, GDF-15 (p = 0.029; cut-off 1172.0 pg/mL) and BNP (p < 0.001; cut-off 2194.0 pg/mL) showed significant results. Consequently, analyses of combined biomarkers were performed, which yielded IGF-BP2 + BNP (AUC = 0.721; 95%CI = 0.585−0.857; p = 0.004) as the best result of the two-way analyses and GDF-15 + IGF-BP2 + BNP (AUC = 0.727; 95%CI = 0.590−0.864; p = 0.004) as the best result of the three-way analyses. No significant difference regarding the 1-year survival between patients with PA/BSA < 16.6 mm/m2 and patients with PA/BSA ≥ 16.6 mm/m2 was found (log-rank test: p = 0.452). (4) Conclusions: Although PA/BSA aims to reduce the bias of the PA value caused by different body compositions and sizes, it is still a controversial parameter for diagnosing PH. Combining the parameter with different cardiovascular biomarkers did not lead to a significant increase in the diagnostic precision for detecting PH in patients with severe AS.
Collapse
|
12
|
NT-pro-BNP as a Predictor for Recurrence of Atrial Fibrillation after Primary Cryoballoon Pulmonary Vein Isolation. J Clin Med 2022; 11:jcm11247400. [PMID: 36556020 PMCID: PMC9783297 DOI: 10.3390/jcm11247400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 12/06/2022] [Accepted: 12/11/2022] [Indexed: 12/15/2022] Open
Abstract
NT-pro-BNP is produced in the cardiac atria and ventricles in response to increased wall stress. It may be a marker of both AF disease progression and co-morbidities that affect success after pulmonary vein isolation (PVI). This single-center retrospective study analyzed the association between pre-procedural NT-pro-BNP serum levels and the long-term outcome after a first-ever PVI in cryo-technique. Patients were followed by searching the hospital information system and conducting structured telephone interviews. Treatment failure was defined as any relapse of atrial fibrillation (AF) occurring 90 days after the index PVI at the earliest. Kaplan−Meier survival curves and Cox proportional hazards models were computed to assess the impact of NT-pro-BNP on AF recurrence. Following 374 patients over a median of 3.8 years (range: 0.25−9.4 years), baseline NT-pro-BNP was associated with the combined endpoint in univariate analysis (HR 1.04 per 100 pg/mL increase, 95% CI: 1.02−1.07, p < 0.001). Results were virtually unchanged in the multivariate model or if the data were log-transformed. Intraprocedural left atrial pressure correlated positively with log NT-pro-BNP. NT-pro-BNP was associated with AF relapse during a long-term follow-up after first-ever cryo-PVI in our cohort of patients with predominantly normal left ventricular function. This lab parameter is easy to obtain and has significant potential to guide treatment decisions.
Collapse
|
13
|
Comparability between Computed Tomography Morphological Vascular Parameters and Echocardiography for the Assessment of Pulmonary Hypertension in Patients with Severe Aortic Valve Stenosis-Results of a Multi-Center Study. Diagnostics (Basel) 2022; 12:diagnostics12102363. [PMID: 36292052 PMCID: PMC9600691 DOI: 10.3390/diagnostics12102363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 09/23/2022] [Accepted: 09/26/2022] [Indexed: 12/03/2022] Open
Abstract
Background: Computed tomography (CT) of the aorta and cardiac vessels, which is performed in patients with severe aortic valve stenosis (AS) before transcatheter aortic valve replacement (TAVR), offers the possibility of non-invasive detection of pulmonary hypertension (PH), for example, by determining the diameter of the main pulmonary artery (PA), the right pulmonary artery (RPA) or the left pulmonary artery (LPA). An improvement of the significance of these radiological parameters is often achieved by indexing to the body surface area (BSA). The aim of this study was to compare different echocardiographic systolic pulmonary artery pressure (sPAP) values with radiological data in order to define potential clinical cut-off values for the presence or absence of PH. Methods: A total of 138 patients with severe AS undergoing TAVR underwent pre-interventional transthoracic echocardiography with determination of sPAP values and performance of CT angiography (CTA) of the aorta and femoral arteries. Radiologically, the PA, RPA, LPA, and ascending aorta (AA) diameters were obtained. Vascular diameters were not only indexed to BSA but also ratios were created with AA diameter (for example PA/AA-ratio). From these CT-derived vascular parameters, AUROC curves were obtained regarding the prediction of different sPAP values (sPAP 40−45−50 mmHg) and finally correlation analyses were calculated. Results: The best AUROC and correlation analyses were generally obtained at an sPAP ≥ 40 mmHg. When considering diameters alone, the PA diameter was superior to the RPA and LPA. Indexing to BSA generally increased the diagnostic quality of the parameters, and finally, in a synopsis of all results, PA/BSA had the best AUC 0.741 (95% CI 0.646−0. 836; p < 0.001; YI 0.39; sensitivity 0.87; specificity 0.52) and Spearman’s correlation coefficient (r = 0.408; p < 0.001) at an sPAP of ≥40 mmHg. Conclusions: Features related to pulmonary hypertension are fast and easily measurable on pre-TAVR CT and offer great potential regarding non-invasive detection of pulmonary hypertension in patients with severe AS and can support the echocardiographic diagnosis. In this study, the diameter of the main pulmonary artery with the additionally determined ratios were superior to the values of the right and left pulmonary artery. Additional indexing to body surface area and thus further individualization of the parameters with respect to height and weight can further improve the diagnostic quality.
Collapse
|
14
|
CT-Diagnosed Sarcopenia and Cardiovascular Biomarkers in Patients Undergoing Transcatheter Aortic Valve Replacement: Is It Possible to Predict Muscle Loss Based on Laboratory Tests?—A Multicentric Retrospective Analysis. J Pers Med 2022; 12:jpm12091453. [PMID: 36143238 PMCID: PMC9505474 DOI: 10.3390/jpm12091453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 08/29/2022] [Accepted: 09/02/2022] [Indexed: 11/16/2022] Open
Abstract
Background: Patients with severe aortic valve stenosis (AS) often present with heart failure and sarcopenia. Sarcopenia, described as progressive degradation of skeletal muscle mass, has frequently been implicated as a cause of increased mortality, prolonged hospitalization and generalized poor outcome after transcatheter aortic valve replacement (TAVR). At present, sarcopenia is defined by the European Working Group on Sarcopenia in Older People (EWGSOP) based on clinical examination criteria and radiological imaging. The aim of the present study was to compare patients with Computed Tomography (CT)-diagnosed sarcopenia with regard to the expression of cardiovascular biomarkers in order to obtain additional, laboratory-chemical information. Methods: A total of 179 patients with severe AS were included in this retrospective study. Sarcopenia was determined via CT by measurement of the psoas muscle area (PMA), which was indexed to body surface area (PMAi). According to previous studies, the lowest tertile was defined as sarcopenic. Patients with (59/179) and without sarcopenia (120/179) in the overall cohort were compared by gender-specific cut-offs with regard to the expression of cardiovascular biomarkers such as brain natriuretic peptide (BNP), soluble suppression of tumorigenicity-2 (sST2), growth/differentiation of factor-15 (GDF-15), heart-type fatty-acid binding protein (H-FABP), insulin like growth factor binding protein 2 (IGF-BP2) and soluble urokinase-type plasminogen activator receptor (suPAR). Additionally, binary logistic regression analyses were calculated to detect possible predictors of the presence of sarcopenia. Results: No statistical differences regarding one-year survival could be detected between sarcopenic and non-sarcopenic patients in survival curves (log rank test p = 0.179). In the entire cohort, only BNP and hemoglobin (HB) showed a statistically significant difference, with only HB emerging as a relevant predictor for the presence of sarcopenia after binary logistic regression analysis (p = 0.015). No relevant difference in biomarker expression could be found in the male cohort. Regarding the female cohort, statistically significant differences were found in BNP, HB and hematocrit (HK). In binary logistic regression, however, none of the investigated criteria could be related to sarcopenia. Conclusion: Regardless of gender, patients with imaging-based muscle degradation did not demonstrate significantly different cardiovascular biomarker expression compared to those without it.
Collapse
|
15
|
Systolic Pulmonary Artery Pressure and Cardiovascular Biomarkers—New Non-Invasive Ways to Detect Pulmonary Hypertension in Patients with Severe Aortic Valve Stenosis Undergoing TAVR? Rev Cardiovasc Med 2022. [DOI: 10.31083/j.rcm2307224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
|
16
|
Protocol for the Exercise, Cancer and Cognition - The ECCO-Study: A Randomized Controlled Trial of Simultaneous Exercise During Neo-/Adjuvant Chemotherapy in Breast Cancer Patients and Its Effects on Neurocognition. Front Neurol 2022; 13:777808. [PMID: 35401389 PMCID: PMC8990905 DOI: 10.3389/fneur.2022.777808] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Accepted: 02/10/2022] [Indexed: 12/21/2022] Open
Abstract
Introduction Epidemiological studies show that increased physical activity is linked to a lower risk of breast cancer and mortality. As a result, physical activity can significantly improve patients' quality of life (QOL) both during and after therapy.Many breast cancer patients demonstrate a decrease in cognitive capacity, referred to as the symptom-complex cancer related cognitive impairment (CRCI). Most frequently reported impairments are mild to moderate deficits in processing speed, attention, memory, and executive functions. Cognitive symptoms persist for months or even years, following medical treatment in roughly 35% of afflicted people, impairing everyday functioning, limiting the ability to return to work, and lowering the overall QOL. Recent studies point toward a key role of inflammatory pathways in the CRCI genesis. Attention to physical activity as a potential supportive care option is therefore increasing. However, evidence for the positive effects of exercise on preventing CRCI is still lacking. Patients and Methods Against this background, the prospective, two-arm, 1:1 randomized, controlled trial investigates the influence of first line chemotherapy accompanied by exercise training on preventing CRCI in 126 patients with breast cancer at the local University Hospital. The study will evaluate biomarkers and secondary assessments suspected to be involved in the pathogenesis of CRCI in addition to objective (primary outcome) and subjective cognitive function. CRCI is believed to be connected to either functional and/or morphological hippocampal damage due to chemotherapy. Thus, cerebral magnetic resonance imaging (MRI) and hippocampal volume measurements are performed. Furthermore, a specific neuropsychological test battery for breast cancer patients has been developed to detect early signs of cognitive impairments in patients and to be integrated into practice. Discussion This study will explore how a long-term supervised exercise intervention program might prevent CRCI, enables optimization of supportive care and objectifies limits of psychological and physical resilience in breast cancer patients during and after chemotherapy treatment. Trial Registration ClinicalTrials.gov: Identifier: NCT04789187. Registered on 09 March 2021.
Collapse
|
17
|
Delayed Total Atrioventricular Block After Transcatheter Aortic Valve Replacement Assessed by Implantable Loop Recorders. JACC Cardiovasc Interv 2021; 14:2723-2732. [PMID: 34949397 DOI: 10.1016/j.jcin.2021.09.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 08/19/2021] [Accepted: 09/07/2021] [Indexed: 12/19/2022]
Abstract
OBJECTIVES The aims of this study were to evaluate the rate and time course of delayed total atrioventricular block (DT-AVB) after transcatheter aortic valve replacement (TAVR) using continuous electrocardiographic monitoring by implantable loop recorders and to identify potential predictors. BACKGROUND DT-AVB has been defined as onset more than 2 days after TAVR or after hospital discharge and is reported in 10% to 15% of patients at 30-day follow-up. To date, there is no standardized diagnostic and therapeutic algorithm to manage TAVR patients at risk for DT-AVB. METHODS Consecutive patients undergoing TAVR and simultaneous electrophysiologic testing without persistent or recurrent total atrioventricular block within 48 hours after the procedure underwent loop recorder implantation for full disclosure of atrioventricular conduction during 12-month follow-up. RESULTS DT-AVB occurred in 7 of 59 patients (11.9%), with onset between 2 days and 3 months after the procedure. Both prolongation of the PQ interval between baseline and day 2 after TAVR (OR: 1.04; 95% CI: 1.01-1.09); P = 0.032) and prolongation of the HV interval during the procedure (OR: 1.07; 95% CI: 1.02-1.14; P = 0.015) significantly predicted the onset of DT-AVB. CONCLUSIONS TAVR was associated with a considerable rate of DT-AVB of nearly 12% in this series. Prolongation of the PQ interval between baseline and day 2 and intraprocedural prolongation of the HV interval were significant predictors of DT-AVB.
Collapse
|
18
|
Tumor necrosis factor alpha-an underestimated risk predictor in patients undergoing transcatheter aortic valve replacement (TAVR)? J Clin Lab Anal 2021; 35:e23977. [PMID: 34562276 PMCID: PMC8605157 DOI: 10.1002/jcla.23977] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Revised: 08/06/2021] [Accepted: 08/14/2021] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Systemic inflammation has been identified as a major cardiovascular risk factor in patients undergoing transcatheter aortic valve replacement (TAVR), yet currently, it is not adequately portrayed in scores for pre-interventional risk assessment. The aim of this study was to investigate the predictive ability of TNF-α in TAVR. METHODS A total of 431 patients undergoing transfemoral TAVR were enrolled in this study. Blood samples were drawn prior to intervention, 24 h post-intervention, 4, 5, and 7 days post-intervention, and 1, 3, and 6 months post-TAVR. RESULTS In a univariate Cox proportional hazard analysis, plasma concentrations of TNF-α after 24 h and after 5 days were associated with mortality after 12 months (after 24 h: HR 1.002 (1.000-1.004), p = 0.028; after 5d: HR 1.003 (1.001-1.005), p = 0.013). This association remained significant even after correction for confounders in a multivariate Cox regression analysis. Additionally, cut-offs were calculated. Patients above the cut-off for TNF-α after 5d had a significantly worse 12-month mortality than patients below the cut-off (18.8% vs. 2.8%, p = 0.046). CONCLUSION Plasma levels of TNF-α after 24 h and 5 days were independently associated with 12-month mortality in patients undergoing TAVR. Thus, TNF-α could represent a novel biomarker for enhanced risk stratification in these patients.
Collapse
|
19
|
Leadless pacemakers in critically ill patients requiring prolonged cardiac pacing: A multicenter international study. J Cardiovasc Electrophysiol 2021; 32:2522-2527. [PMID: 34270153 DOI: 10.1111/jce.15175] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 06/08/2021] [Accepted: 07/07/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND Temporary transvenous pacing in critically ill patients requiring prolonged cardiac pacing is associated with a high risk of complications. We sought to evaluate the safety and efficacy of self-contained intracardiac leadless pacemaker (LPM) implantation in this population. METHODS AND RESULTS Consecutive patients implanted with a Micra LPM during the hospitalization in an intensive care unit were retrospectively included. Inclusion criteria were: more than or equal to 1 supracaval central venous line, or a ventilation tube, or intravenous antibiotic therapy for ongoing sepsis or bacteremia. Patients with a history of the previous implantation of a pacemaker were excluded. Out of 1016 patients implanted with an LPM, 99 met the inclusion criteria. Mean age was 75 years and Charlson comorbidity index 7. LPM implantation was successfully performed in 98% of cases, with a perioperative complication rate of 5%, mainly cardiac injuries. In-hospital mortality rate was 6%. No late (>30 days) device-related complication occurred, especially no infection. CONCLUSIONS LPM appears as an acceptable alternative to conventional temporary transvenous pacing in selected critically ill patients requiring prolonged cardiac pacing, especially regarding the risk of infection.
Collapse
|
20
|
Transapical off-pump mitral valve repair following prior mitral valve surgery: A case report. Medicine (Baltimore) 2021; 100:e26148. [PMID: 34032769 PMCID: PMC8154387 DOI: 10.1097/md.0000000000026148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Accepted: 05/11/2021] [Indexed: 01/04/2023] Open
Abstract
RATIONALE Redo surgeries after mitral valve repair are technically demanding. Procedures applying the NeoChord device (NeoChord Inc, St. Louis Park, MN) have proven to be safe and feasible in selected patients requiring mitral valve repair due to a leaflet prolapse or flail. However, its use for redo procedures after conventional surgical repair has not been well established yet. PATIENT CONCERNS We report the case of a 57-year-old man who presented with dyspnea upon exertion. The patient had undergone a minimally invasive surgical mitral valve repair because of a flail leaflet of the segments segment 2 of the posterior mitral valve leaflet (P2)/segment 3 of the posterior mitral valve leaflet (P3) 4 years before. DIAGNOSES Transesophageal echocardiography identified a relapse of severe mitral valve regurgitation. The recurring regurgitant jet was caused by a flail leaflet due to newly ruptured native chords. INTERVENTIONS After discussion in an interdisciplinary heart team, we performed a minimally invasive off-pump redo procedure applying the NeoChord device under three-dimensional transesophageal echocardiographic guidance. OUTCOMES The echocardiographic result with only trivial residual mitral regurgitation as well as the further clinical course of the patient were favorable. LESSONS As redo surgery after minimally invasive mitral valve repair is challenging, the NeoChord device represents a novel treatment option that does not require cardiopulmonary bypass.
Collapse
|
21
|
Association of adipocytokines serum levels with left atrial thrombus formation in atrial fibrillation patients on oral anticoagulation (Alert) - A cross-sectional study. Nutr Metab Cardiovasc Dis 2021; 31:860-868. [PMID: 33549449 DOI: 10.1016/j.numecd.2020.11.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2020] [Revised: 10/25/2020] [Accepted: 11/06/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND AND AIMS Oral anticoagulation is effective for stroke prevention in atrial fibrillation (AF). However, strokes may still occur in high-risk individuals. We conducted a prospective trial to assess the association between adipocytokine serum levels and surrogate parameters for thromboembolic events. METHODS AND RESULTS In this cross-sectional multicenter trial, we enrolled 189 patients with AF who were on oral anticoagulation. The primary endpoint was defined as either the presence of spontaneous echo contrast (SEC), a left atrial appendage (LAA), or a left atrial (LA) thrombus on transesophageal echocardiography. We investigated the association of adipocytokine serum levels with the combined endpoint using logistic regression analysis. Forty-eight individuals (25%) were assigned to group 1 (G1) due to the occurrence of at least one of the components of the combined endpoint (41 [21.7%] SEC, 3 [1.6%] LA thrombus, 13 [6.9%] LAA thrombus), whereas the remaining patients formed group 2 (G2). The BMI, logarithmized (loge) leptin (G1: 2.0 ± 1.3 μg/ml, G2: 2.0 ± 1.1 μg/ml, p = 0.746) and visfatin serum levels (G1: 3.4 ± 0.3 ng/ml, G2: 3.4 ± 0.5 ng/ml, p = 0.900) did not significantly differ between the groups. Conversely, logarithmized adiponectin (G1: 3.3 ± 0.6 ng/ml, G2: 3.1 ± 0.7 ng/ml, p = 0.036) and resistin levels (G1: 1.8 ± 0.5 ng/ml, G2: 1.6 ± 0.5 ng/ml, p = 0.009) were higher in patients with the primary endpoint. Multivariate logistic regression analysis using a score that combined the individual adiponectin and resistin values in each patient corroborated this association. CONCLUSIONS Our results suggest that adiponectin and resistin may act as potential biomarkers to identify individuals with AF who are at high thromboembolic risk.
Collapse
|
22
|
Transcatheter pacing system replacement for AV synchrony. Europace 2021; 23:1786. [PMID: 33693654 DOI: 10.1093/europace/euab045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Indexed: 11/12/2022] Open
|
23
|
Predictors of true-severe classical low-flow low-gradient aortic stenosis at resting echocardiography. Int J Cardiol 2021; 335:93-97. [PMID: 33662487 DOI: 10.1016/j.ijcard.2021.02.070] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Revised: 12/26/2020] [Accepted: 02/15/2021] [Indexed: 10/22/2022]
Abstract
BACKGROUND Classical low-flow, low-gradient (LF/LG) aortic stenosis (AS) is subclassified into a true-severe (TS) and a pseudo-severe (PS) subform using low-dose dobutamine stress echocardiography (DSE). In clinical practice a resting peak jet velocity (Vmax) >3.5 m/s or a mean transvalvular gradient (MPG) >35 mmHg suggests the presence of TS classical LF/LG AS, but there is no data to support this. The aim of this study was therefore to investigate whether a resting Vmax >3.5 m/s or MPG >35 mmHg reliably predicted diagnosis of TS classical LF/LG AS. METHODS One hundred (100) consecutive patients with classical LF/LG AS were prospectively recruited. All patients underwent DSE for subcategorization. The impact of Vmax and MPG for the presence of the TS subform were analyzed. RESULTS TS classical LF/LG AS was diagnosed in 72 patients. Resting Vmax and resting MPG predicted true-severity with an ROC-AUC of 0.737 (95%CI: 0.635-0.838; p < 0.001) and 0.725 (95%CI: 0.615-0.834; p < 0.001), respectively. The optimal positive predictive values (PPV) for the diagnosis of TS classical LF/LG AS were obtained with a resting Vmax >3.5 m/s or resting MPG >35 mmHg. In a multivariate logistic regression analysis, Vmax >3.5 m/s was independently associated with a 5.33-fold odds-ratio of TS classical LF/LG AS (OR 5.33; 95%CI: 1.34-21.18, p = 0.018). CONCLUSIONS TS classical LF/LG AS can be reliably predicted by a resting Vmax >3.5 m/s or a resting MPG >35 mmHg. Further imaging for subclassification is not needed in this situation.
Collapse
|
24
|
Upstream Statin Therapy and Long-Term Recurrence of Atrial Fibrillation after Cardioversion: A Propensity-Matched Analysis. J Clin Med 2021; 10:jcm10040807. [PMID: 33671264 PMCID: PMC7922984 DOI: 10.3390/jcm10040807] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Revised: 02/11/2021] [Accepted: 02/12/2021] [Indexed: 11/24/2022] Open
Abstract
The relationship of statin therapy with recurrence of atrial fibrillation (AF) after cardioversion (CV) has been evaluated by several investigations, which provided conflicting results and particularly long-term data is scarce. We sought to examine whether upstream statin therapy is associated with long-term recurrence of AF after CV. This was a single-center registry study including consecutive AF patients (n = 454) undergoing CV. Cox regression models were performed to estimate AF recurrence comparing patients with and without statins. In addition, we performed a propensity score matched analysis with a 1:1 ratio. Statins were prescribed to 183 (40.3%) patients. After a median follow-up period of 373 (207–805) days, recurrence of AF was present in 150 (33.0%) patients. Patients receiving statins had a significantly lower rate of AF recurrence (log-rank p < 0.001). In univariate analysis, statin therapy was associated with a significantly reduced rate of AF recurrence (HR 0.333 (95% CI 0.225–0.493), p = 0.001), which remained significant after adjustment (HR 0.238 (95% CI 0.151–0.375), p < 0.001). After propensity score matching treatment with statins resulted in an absolute risk reduction of 27.5% for recurrent AF (21 (18.1%) vs. 53 (45.7%); p < 0.001). Statin therapy was associated with a reduced risk of long-term AF recurrence after successful cardioversion.
Collapse
|
25
|
Cardiac Computed Tomography-Derived Left Atrial Volume Index as a Predictor of Long-Term Success of Cryo-Ablation in Patients With Atrial Fibrillation. Am J Cardiol 2021; 140:69-77. [PMID: 33152317 DOI: 10.1016/j.amjcard.2020.10.061] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2020] [Revised: 10/21/2020] [Accepted: 10/27/2020] [Indexed: 10/23/2022]
Abstract
Patients with symptomatic, drug-refractory atrial fibrillation (AF) are frequently treated with catheter ablation. Cryo-ablation has been established as an alternative to radiofrequency ablation but long-term outcome data are still limited. This study aimed at elucidating the influence of the left atrial volume index (LAVI), derived from cardiac computed tomography (cCT) data, on the long-term outcome of ablation-naïve AF patients, after their first cryo-ablation. 415 patients (n = 290 [69.90%] male, 60.00 [IQR: 53.00 to 68.00] years old) who underwent a cCT and subsequent cryo-ablation index procedure were included in this single centre retrospective data analysis. A composite end point was defined (AF on electrocardiogram and/or electric cardioversion and/or re-do). Patients were closely followed for a year and then contacted for long-term follow-up after a median of 53.00 months (IQR: 34.50 to 73.00). Statistical analyses of the outcome and predictors of AF recurrence were conducted. In 224 patients (53.98%) no evidence of AF recurrence could be found. LAVI differed significantly between the positive and adverse (AF recurrence) outcome group (49.96 vs 56.07 ml/m2, p < 0.001). Cox regression analyses revealed cCT LAVI (HR: 1.022, 95% CI: 1.013 to 1.031, p < 0.001), BMI (HR: 1.044, 95% CI: 1.005 to 1.084, p < 0.05) and the type of AF (HR: 1.838 for nonparoxysmal AF, 95% CI: 1.214 to 2.781, p < 0.01) to be effective predictors of AF recurrence. A prognostic cCT LAVI cut-off value of 51.99 ml/m2 was calculated and must be validated in future prospective studies. In conclusion, LAVI is an accurate, yet underutilized predictor of AF recurrence after pulmonary vein isolation with cryo-energy and scores for calculating AF recurrence or progression risks might underemphasize the importance of CT-derived LAVI as a predictive factor.
Collapse
|
26
|
Speckle Tracking-Derived Longitudinal Strain: Validation and Influence of Scanner Settings. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:154-162. [PMID: 33077338 DOI: 10.1016/j.ultrasmedbio.2020.09.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 09/09/2020] [Accepted: 09/13/2020] [Indexed: 06/11/2023]
Abstract
Speckle tracking-based strain analysis is an evolving technique for the assessment of left ventricular function. We evaluated the influence of machine settings on global longitudinal peak systolic strain (GLPSS) values in an everyday patient population (n = 35). In each patient, the four-chamber view was recorded multiple times with different machine parameters. Ejection fraction ranged between 10% and 76% and correlated well with GLPSS (r = -0.778). GLPSS was not altered systematically by modifications of gain and frame rate. Conversely, higher transducer frequencies (mean effect: 1.102%/MHz, p < 0.001, and 0.662%/MHz, p = 0.033, for harmonic and fundamental imaging frequencies, respectively) and lower sector depth (mean effect: -0.156%/cm, p < 0.001) were associated with a slight-but statistically significant-reduction in absolute GLPSS values. Intra- and inter-observer variability exhibited satisfactory repeatability. GLPSS analysis proved to be reproducible and robust in our patient cohort if common settings for adult echocardiography were applied.
Collapse
|
27
|
Intraprocedural dynamics of cardiac conduction during transcatheter aortic valve implantation: Assessment by simultaneous electrophysiological testing. Heart Rhythm 2020; 18:419-425. [PMID: 33250391 DOI: 10.1016/j.hrthm.2020.10.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 10/18/2020] [Accepted: 10/20/2020] [Indexed: 11/29/2022]
Abstract
BACKGROUND Transcatheter aortic valve implantation (TAVI) is an established treatment for patients with severe aortic stenosis and high to intermediate surgical risk. However, the proximity of the conduction system to the prosthesis landing zone bears the risk of atrioventricular conduction disorders. The underlying pathophysiology is not fully understood. OBJECTIVE The purpose of this study was to characterize the impact of TAVI on the conduction system as assessed by simultaneous electrophysiological testing. METHODS AH and HV intervals and QRS duration were measured using a quadripolar His catheter and surface electrocardiogram in 108 patients at baseline (BL), after balloon predilation (timepoint 1 [T1]), after implantation of the valve prosthesis (T2), and after postdilation, if deemed necessary (T3). RESULTS Between BL and T2, significant increases of HV interval and QRS duration were observed, with a mean delta of +12.4 ms and +32.7 ms, respectively. Both balloon predilation and valve implantation had an impact on infranodal conduction. No significant increase of AH intervals was documented. The increase of QRS duration led to left bundle branch block (LBBB) in 57 patients (52.8%). Implantation depth positively correlated with QRS prolongation (ρ = 0.21, P = .042) but not with changes of AH or HV interval (ρ = -0.03, P = .762; and ρ = 0.15, P = .130, respectively). CONCLUSION Electrophysiological testing during TAVI shows impairment of infranodal atrioventricular conduction by balloon predilation and valve implantation. This impairment is positively correlated with valve implantation depth and results in an increase of QRS duration with mainly LBBB pattern on surface electrocardiogram.
Collapse
|
28
|
High-molecular-weight von Willebrand Factor multimer ratio differentiates true-severe from pseudo-severe classical low-flow, low-gradient aortic stenosis. Eur Heart J Cardiovasc Imaging 2020; 21:1123-1130. [PMID: 32417907 DOI: 10.1093/ehjci/jeaa056] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Accepted: 03/07/2020] [Indexed: 01/15/2023] Open
Abstract
AIMS Upon high wall shear stress, high-molecular-weight (HMW) von Willebrand Factor (VWF) multimers are degraded, thus, HMW VWF multimer deficiency mirrors haemodynamics at the site of aortic stenosis (AS). The aim of the present study was to analyse the role of HMW VWF multimer ratio for subcategorization of classical low-flow, low-gradient (LF/LG) AS. METHODS AND RESULTS Eighty-three patients with classical LF/LG AS were prospectively recruited and HMW VWF multimer pattern was analysed using a densitometric quantification of western blot bands. Patients were subclassified into true-severe (TS) and pseudo-severe (PS) classical LF/LG AS based on dobutamine stress echocardiography (DSE). Positive and negative predictive values (PPV/NPV) of HMW VWF multimer ratio for diagnosis of the TS subtype were calculated. HMW VWF multimer ratio in TS classical LF/LG AS was significantly decreased compared to PS classical LF/LG AS (0.86 ± 0.27 vs. 1.06 ± 0.09, P < 0.001). HMW VWF multimer deficiency occurred exclusively in the TS subtype with an optimal PPV of 1.000 and NPV of 0.379. HMW VWF multimer ratio showed a strong correlation with mean transvalvular pressure gradients during DSE (r = -0.616; P < 0.001). HMW VWF multimer ratio measured at baseline was higher compared to levels measured after DSE (0.87 ± 0.27 vs. 0.84 ± 0.31; P = 0.031) indicating DSE-induced increased proteolysis. CONCLUSION HMW VWF multimer ratio represents a valuable biomarker for classical LF/LG AS subclassification and mirrors haemodynamics during DSE. HMW VWF multimer ratio identifies the TS subtype without the use of other imaging techniques.
Collapse
|
29
|
P968Impact of contact force sensing catheters on fluoroscopy time in left-sided atrial procedures. Europace 2020. [DOI: 10.1093/europace/euaa162.359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Funding Acknowledgements
None.
OnBehalf
Go for Zero Fluoroscopy Project investigators
Background Contact force sensing catheters provide electrophysiologists with direct feedback and therefore improve safety and help to generate more effective lesions. The use of contact force may also reduce fluoroscopy and procedure times.
Purpose The aim of this study was to systematically evaluate the impact of using contact force sensing catheters (CFSCs) on fluoroscopy times and procedure times in left-sided atrial procedures.
Methods In this multinational, multicenter study, data from 622 left-sided procedures (142 without and 480 with CFSCs) of 25 participating European centers were prospectively collected with a structured questionnaire. Examinations comprised 393 pulmonary vein isolations (PVIs, group 1[G1]), 122 PVIs with linear lesions (group 2[G2]), 65 left-sided accessory pathway ablations (group 3 [G3]) and 42 ablations for left atrial tachycardia (group 4 [G4]). Fluoroscopy and procedure times were compared with respect to the use of CFSCs, procedure type, and level of operator experience as possible confounders. A Mann-Whitney U-test was applied for comparison, and a p-value <0.05 was considered statistically significant.
Results With the use of CFSCs, fluoroscopy time was significantly reduced when performing pulmonary vein isolations (G1 median [IQR]: 19 [11.0-33.7] vs. 7.2 [4.0-13.0] min., p < 0.001, G2: 45.3 [34.9-61.8] vs. 7.3 [5.0-14.0], p < 0.001, respectively). For groups G3 and G4, no difference could be detected. Procedure times were shortened for pulmonary vein isolations with additional lesions only (G4: 210 [180-240] vs. 153 [127-200] min., p < 0.001). When assessing the effect of operator experience, all left-sided atrial procedures were combined. Significantly shorter fluoroscopy times with contact force were found at all career levels (early career < 5 years: median -6 min., p = 0.024, mid-career 5-15 years: -15 min., p < 0.001, mentor status with experience > 15 years: -6.5 min., p < 0.001). The use of contact force proved to be especially beneficial in reducing fluoroscopy time in operators performing one to 19 procedures per month (1-9: median -15.8 min., p < 0.001, 10-19: -15.9 min., p < 0.001), whereas it lost its statistical significance when more than 20 procedures per month were performed (20-39: - 3.2 min., p = 0.100, >40: -1.5 min., p = 0.346).
Conclusion Contact force sensing catheters can help to reduce fluoroscopy times, especially when performing pulmonary vein isolations. This effect could be demonstrated for all career levels. However, it diminished with the operator"s caseload. A shortening of procedure time was found for PVIs with additional linear lesions.
Collapse
|
30
|
Self-assessment of medical students and young physicians in training : Self-confidence of clinical competencies and working or learning environment. Wien Klin Wochenschr 2020; 132:155-160. [PMID: 32130522 DOI: 10.1007/s00508-020-01623-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Accepted: 02/13/2020] [Indexed: 10/24/2022]
Abstract
BACKGROUND In 2015 medical training regulations have been restructured for postgraduate medical training in Austria resulting in a significant shortening of the training period. Furthermore, a restriction of working hours for physicians to 48 h per week was implemented affecting the framework of postgraduate medical training. The aim of this study was to obtain a self-assessment of students and young physicians in Austria regarding their self-confidence in clinical skills and their working and learning environment. METHODS In this study 6th year medical students, physicians in their basic training (common trunk), physicians in family medicine training, and residents in their first 18 months of training were asked to participate in a survey. Self-reported data were collected for five different prespecified domains (communication, motor skills, knowledge, documentation, and emergency). RESULTS In all domains, self-confidence increased significantly during medical training. Analysis further revealed better results of residents compared with all other groups in all domains, whereas physicians in family medicine training only rated themselves better in the documentation domain (p = 0.010); however, the interest in family medicine was low, even among physicians in family medicine training. The workload significantly increased during medical education, with the highest stress levels for physicians in family medicine training and residents (p = 0.001). CONCLUSIONS Self-confidence of young physicians but also their stress levels increased during the medical training. Further studies are needed to answer the question why the interest in family medicine was so unexpectedly low in this cohort.
Collapse
|
31
|
Impact of catheter ablation therapy for atrial fibrillation on healthcare expenditures in a middle European cohort. Europace 2020; 22:576-583. [DOI: 10.1093/europace/euz362] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Accepted: 12/13/2019] [Indexed: 11/13/2022] Open
Abstract
Abstract
Aims
Atrial fibrillation (AF) is the most prevalent arrhythmia in western countries. It is associated with increased mortality and morbidity and responsible for hospitalization rates of 10–40% per patient per year. Studies from the UK and the USA have shown that AF is responsible for ∼1% of the total healthcare expenditures in these countries. The only potentially curative treatment is pulmonary vein isolation (PVI). Published health economic data on the impact of PVI mainly consist of simulations of expenditures with assumed efficacy taken from ablation studies. Real expenditure data are missing as well as pre-ablation period data and long-term data.
Methods and results
We analyse true healthcare expenditures based on inpatient and outpatient data from the Upper Austrian Health Insurance Fund social security system of patients undergoing PVI during 2005 to 2015. We identified 1135 patients undergoing PVI with 268 having multiple procedures. Days of hospitalization and days of sick leave started to rise in the year before ablation. PVI was able to lower both parameters to the level of 1 year before ablation. Comparing four quarters before and after a single-index ablation, a highly significant reduction in inpatient healthcare expenditures was documented. There was a significant, but numerically small increase in outpatient expenditures, resulting in a significant reduction in overall healthcare expenditures.
Conclusion
Analysing a cohort of the Upper Austrian Health Insurance Fund undergoing PVI, we found significant cost-saving effects on post-interventional healthcare expenditures and a reduction in days of sick leave.
Collapse
|
32
|
P1540 Imaging parameters vs. operator dependence of global longitudinal strain values. Eur Heart J Cardiovasc Imaging 2020. [DOI: 10.1093/ehjci/jez319.961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
Background
Speckle tracking based global longitudinal strain (GLS) values have proven useful in the assessment of subtle changes in left ventricular function. From a clinical point of view, robustness and reliability of measured values are critical to ensure a valid patient assessment and follow-up. However, it is still a matter of debate if imaging parameters systematically alter measured strain values and if these changes are relevant as compared with GLS fluctuations that are caused by different operators or different studies by the same operator.
Methods
In a consecutive everyday patient population (n = 35), we recorded the apical four chamber view several times in each patient with different ultrasound machine settings (modification of gain, frame rate, sector depth, and transducer frequencies) using a commercially available ultrasound imaging system. Furthermore, apical four chamber views with ‘optimized’ imaging settings at the operators’ discretion were recorded by two different observers (obA/obB) in each subject to compute inter- and intra-observer variability. GLS values were calculated offline with a dedicated software. We fitted a linear mixed effects model with random intercept and slope to assess the effect of imaging parameters on GLS and compared the two investigators with Bland-Altman plots.
Results
Ejection fraction ranged between 10% and 76% and was correlated well with GLS (r = -0.78). Neither gain settings (range: -24 to 24 arbitrary units, p = 0.68) nor frame rate (range: 51-113 sec-1, p = 0.77) systematically changed measured GLS values. Conversely, higher sector depth increased (range: 12 to 24 cm, mean effect: -0.16%/cm; 95% CI -0.24% to -0.07%, p < 0.01), and higher transducer imaging frequencies decreased absolute GLS values (range for harmonic imaging: 1.5/3.1 MHz to 2.0/4.3 MHz, mean effect 1.10%/MHz; 95% CI 0.61% to 1.59%, p < 0.01). According to our data, a 12 cm increase of sector depth would translate into an average change of -1.87% GLS (95% CI: -2.87% to -0.86%), whereas a switch of the second harmonic imaging frequency from 3.1 MHz to 4.3 MHz would cause a 1.32% GLS change (95% CI: 0.73% to 1.91%). Intra- and inter-observer variability showed good correlation and limits of agreement (obA: mean difference [MD]: -0.20%; 95% limits of agreement [LOA]: -2.42% to 2.02%, p = 0.86, obB: MD: -0.10%; 95% LOA: -4.28% to 4.07%, p = 0.12, obA vs. obB: MD: -0.53%; 95% LOA: -3.68% to 2.62%, p = 0.92).
Conclusion
Overall, GLS values were robust and reproducible in our cohort of patients. In comparison, potential systematic changes of GLS values caused by modification of imaging parameters (sector depth/transducer frequency) were much less in number than GLS variations caused by different operators or different studies by the same operator.
Collapse
|
33
|
State of the art: leadless ventricular pacing : A national expert consensus of the Austrian Society of Cardiology. J Interv Card Electrophysiol 2019; 57:27-37. [PMID: 31863250 PMCID: PMC7036055 DOI: 10.1007/s10840-019-00680-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Accepted: 12/02/2019] [Indexed: 01/25/2023]
Abstract
Background Cardiac pacing has been shown to improve quality of life and prognosis of patients with bradycardia for almost 60 years. The latest innovation in pacemaker therapy was miniaturization of generators to allow leadless pacing directly in the right ventricle. There is a long history and extensive experience of leadless ventricular pacing in Austria. However, no recommendations of national or international societies for indications and implantation of leadless opposed to transvenous pacing systems have been published so far. Results A national expert panel of skilled implanters gives an overview on the two utilized leadless cardiac pacing systems and highlights clinical advantages as well as current knowledge of performance and complication rates of leadless pacing. Furthermore, a national consensus for Austria is presented, based on recent studies and current know-how, specifically including indications for leadless pacing, management of infection, suggestions for qualification, and training of the operators and technical standards. Conclusions Leadless pacing systems can be implanted successfully with a low complication rate, if suggestions for indications and technical requirements are followed. Condensed abstract An overview of the two utilized leadless cardiac pacing systems is given, specifically highlighting clinical advantages as well as current knowledge of performance and complication rates. Furthermore, a national consensus for Austria is presented, specifically including indications for leadless pacing, management of infection, and suggestions for qualification and technical standards.
Collapse
|
34
|
Perioperative beta-blockers for preventing surgery-related mortality and morbidity in adults undergoing non-cardiac surgery. Cochrane Database Syst Rev 2019; 9:CD013438. [PMID: 31556094 PMCID: PMC6761481 DOI: 10.1002/14651858.cd013438] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
BACKGROUND Randomized controlled trials (RCTs) have yielded conflicting results regarding the ability of beta-blockers to influence perioperative cardiovascular morbidity and mortality. Thus routine prescription of these drugs in an unselected population remains a controversial issue. A previous version of this review assessing the effectiveness of perioperative beta-blockers in cardiac and non-cardiac surgery was last published in 2018. The previous review has now been split into two reviews according to type of surgery. This is an update, and assesses the evidence in non-cardiac surgery only. OBJECTIVES To assess the effectiveness of perioperatively administered beta-blockers for the prevention of surgery-related mortality and morbidity in adults undergoing non-cardiac surgery. SEARCH METHODS We searched CENTRAL, MEDLINE, Embase, CINAHL, Biosis Previews and Conference Proceedings Citation Index-Science on 28 June 2019. We searched clinical trials registers and grey literature, and conducted backward- and forward-citation searching of relevant articles. SELECTION CRITERIA We included RCTs and quasi-randomized studies comparing beta-blockers with a control (placebo or standard care) administered during the perioperative period to adults undergoing non-cardiac surgery. If studies included surgery with different types of anaesthesia, we included them if 70% participants, or at least 100 participants, received general anaesthesia. We excluded studies in which all participants in the standard care control group were given a pharmacological agent that was not given to participants in the intervention group, studies in which all participants in the control group were given a beta-blocker, and studies in which beta-blockers were given with an additional agent (e.g. magnesium). We excluded studies that did not measure or report review outcomes. DATA COLLECTION AND ANALYSIS Two review authors independently assessed studies for inclusion, extracted data, and assessed risks of bias. We assessed the certainty of evidence with GRADE. MAIN RESULTS We included 83 RCTs with 14,967 participants; we found no quasi-randomized studies. All participants were undergoing non-cardiac surgery, and types of surgery ranged from low to high risk. Types of beta-blockers were: propranolol, metoprolol, esmolol, landiolol, nadolol, atenolol, labetalol, oxprenolol, and pindolol. In nine studies, beta-blockers were titrated according to heart rate or blood pressure. Duration of administration varied between studies, as did the time at which drugs were administered; in most studies, it was intraoperatively, but in 18 studies it was before surgery, in six postoperatively, one multi-arm study included groups of different timings, and one study did not report timing of drug administration. Overall, we found that more than half of the studies did not sufficiently report methods used for randomization. All studies in which the control was standard care were at high risk of performance bias because of the open-label study design. Only two studies were prospectively registered with clinical trials registers, which limited the assessment of reporting bias. In six studies, participants in the control group were given beta-blockers as rescue therapy during the study period.The evidence for all-cause mortality at 30 days was uncertain; based on the risk of death in the control group of 25 per 1000, the effect with beta-blockers was between two fewer and 13 more per 1000 (risk ratio (RR) 1.17, 95% confidence interval (CI) 0.89 to 1.54; 16 studies, 11,446 participants; low-certainty evidence). Beta-blockers may reduce the incidence of myocardial infarction by 13 fewer incidences per 1000 (RR 0.72, 95% CI 0.60 to 0.87; 12 studies, 10,520 participants; low-certainty evidence). We found no evidence of a difference in cerebrovascular events (RR 1.65, 95% CI 0.97 to 2.81; 6 studies, 9460 participants; low-certainty evidence), or in ventricular arrhythmias (RR 0.72, 95% CI 0.35 to 1.47; 5 studies, 476 participants; very low-certainty evidence). Beta-blockers may reduce atrial fibrillation or flutter by 26 fewer incidences per 1000 (RR 0.41, 95% CI 0.21 to 0.79; 9 studies, 9080 participants; low-certainty evidence). However, beta-blockers may increase bradycardia by 55 more incidences per 1000 (RR 2.49, 95% CI 1.74 to 3.56; 49 studies, 12,239 participants; low-certainty evidence), and hypotension by 44 more per 1000 (RR 1.40, 95% CI 1.29 to 1.51; 49 studies, 12,304 participants; moderate-certainty evidence).We downgraded the certainty of the evidence owing to study limitations; some studies had high risks of bias, and the effects were sometimes altered when we excluded studies with a standard care control group (including only placebo-controlled trials showed an increase in early mortality and cerebrovascular events with beta-blockers). We also downgraded for inconsistency; one large, well-conducted, international study found a reduction in myocardial infarction, and an increase in cerebrovascular events and all-cause mortality, when beta-blockers were used, but other studies showed no evidence of a difference. We could not explain the reason for the inconsistency in the evidence for ventricular arrhythmias, and we also downgraded this outcome for imprecision because we found few studies with few participants. AUTHORS' CONCLUSIONS The evidence for early all-cause mortality with perioperative beta-blockers was uncertain. We found no evidence of a difference in cerebrovascular events or ventricular arrhythmias, and the certainty of the evidence for these outcomes was low and very low. We found low-certainty evidence that beta-blockers may reduce atrial fibrillation and myocardial infarctions. However, beta-blockers may increase bradycardia (low-certainty evidence) and probably increase hypotension (moderate-certainty evidence). Further evidence from large placebo-controlled trials is likely to increase the certainty of these findings, and we recommend the assessment of impact on quality of life. We found 18 studies awaiting classification; inclusion of these studies in future updates may also increase the certainty of the evidence.
Collapse
|
35
|
Perioperative beta-blockers for preventing surgery-related mortality and morbidity in adults undergoing cardiac surgery. Cochrane Database Syst Rev 2019; 9:CD013435. [PMID: 31544227 PMCID: PMC6755267 DOI: 10.1002/14651858.cd013435] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND Randomized controlled trials (RCTs) have yielded conflicting results regarding the ability of beta-blockers to influence perioperative cardiovascular morbidity and mortality. Thus routine prescription of these drugs in unselected patients remains a controversial issue. A previous version of this review assessing the effectiveness of perioperative beta-blockers in cardiac and non-cardiac surgery was last published in 2018. The previous review has now been split into two reviews according to type of surgery. This is an update and assesses the evidence in cardiac surgery only. OBJECTIVES To assess the effectiveness of perioperatively administered beta-blockers for the prevention of surgery-related mortality and morbidity in adults undergoing cardiac surgery. SEARCH METHODS We searched CENTRAL, MEDLINE, Embase, CINAHL, Biosis Previews and Conference Proceedings Citation Index-Science on 28 June 2019. We searched clinical trials registers and grey literature, and conducted backward- and forward-citation searching of relevant articles. SELECTION CRITERIA We included RCTs and quasi-randomized studies comparing beta-blockers with a control (placebo or standard care) administered during the perioperative period to adults undergoing cardiac surgery. We excluded studies in which all participants in the standard care control group were given a pharmacological agent that was not given to participants in the intervention group, studies in which all participants in the control group were given a beta-blocker, and studies in which beta-blockers were given with an additional agent (e.g. magnesium). We excluded studies that did not measure or report review outcomes. DATA COLLECTION AND ANALYSIS Two review authors independently assessed studies for inclusion, extracted data, and assessed risks of bias. We assessed the certainty of evidence with GRADE. MAIN RESULTS We included 63 studies with 7768 participants; six studies were quasi-randomized and the remaining were RCTs. All participants were undergoing cardiac surgery, and in most studies, at least some of the participants were previously taking beta-blockers. Types of beta-blockers were: propranolol, metoprolol, sotalol, esmolol, landiolol, acebutolol, timolol, carvedilol, nadolol, and atenolol. In twelve studies, beta-blockers were titrated according to heart rate or blood pressure. Duration of administration varied between studies, as did the time at which drugs were administered; in nine studies this was before surgery, in 20 studies during surgery, and in the remaining studies beta-blockers were started postoperatively. Overall, we found that most studies did not report sufficient details for us to adequately assess risk of bias. In particular, few studies reported methods used to randomize participants to groups. In some studies, participants in the control group were given beta-blockers as rescue therapy during the study period, and all studies in which the control was standard care were at high risk of performance bias because of the open-label study design. No studies were prospectively registered with clinical trials registers, which limited the assessment of reporting bias. We judged 68% studies to be at high risk of bias in at least one domain.Study authors reported few deaths (7 per 1000 in both the intervention and control groups), and we found low-certainty evidence that beta-blockers may make little or no difference to all-cause mortality at 30 days (risk ratio (RR) 0.95, 95% confidence interval (CI) 0.47 to 1.90; 29 studies, 4099 participants). For myocardial infarctions, we found no evidence of a difference in events (RR 1.05, 95% CI 0.72 to 1.52; 25 studies, 3946 participants; low-certainty evidence). Few study authors reported cerebrovascular events, and the evidence was uncertain (RR 1.37, 95% CI 0.51 to 3.67; 5 studies, 1471 participants; very low-certainty evidence). Based on a control risk of 54 per 1000, we found low-certainty evidence that beta-blockers may reduce episodes of ventricular arrhythmias by 32 episodes per 1000 (RR 0.40, 95% CI 0.25 to 0.63; 12 studies, 2296 participants). For atrial fibrillation or flutter, there may be 163 fewer incidences with beta-blockers, based on a control risk of 327 incidences per 1000 (RR 0.50, 95% CI 0.42 to 0.59; 40 studies, 5650 participants; low-certainty evidence). However, the evidence for bradycardia and hypotension was less certain. We found that beta-blockers may make little or no difference to bradycardia (RR 1.63, 95% CI 0.92 to 2.91; 12 studies, 1640 participants; low-certainty evidence), or hypotension (RR 1.84, 95% CI 0.89 to 3.80; 10 studies, 1538 participants; low-certainty evidence).We used GRADE to downgrade the certainty of evidence. Owing to studies at high risk of bias in at least one domain, we downgraded each outcome for study limitations. Based on effect size calculations in the previous review, we found an insufficient number of participants in all outcomes (except atrial fibrillation) and, for some outcomes, we noted a wide confidence interval; therefore, we also downgraded outcomes owing to imprecision. The evidence for atrial fibrillation and length of hospital stay had a moderate level of statistical heterogeneity which we could not explain, and we, therefore, downgraded these outcomes for inconsistency. AUTHORS' CONCLUSIONS We found no evidence of a difference in early all-cause mortality, myocardial infarction, cerebrovascular events, hypotension and bradycardia. However, there may be a reduction in atrial fibrillation and ventricular arrhythmias when beta-blockers are used. A larger sample size is likely to increase the certainty of this evidence. Four studies awaiting classification may alter the conclusions of this review.
Collapse
|
36
|
Potential mechanisms of endothelialisation in individuals implanted with a leadless pacemaker systems: An experimental in vitro study. J Electrocardiol 2019; 55:72-77. [PMID: 31146075 DOI: 10.1016/j.jelectrocard.2019.04.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Revised: 03/26/2019] [Accepted: 04/20/2019] [Indexed: 10/27/2022]
Abstract
BACKGROUND Leadless pacemaker technology is a promising upcoming field in clinical rhythmology. Today, the most commonly used system in the clinical setting is the Micra™ leadless pacemaker system (Medtronic). In autopsies of patients who witnessed non-pacemaker associated death, unexpected ingrowth/encapsulation within the wall of the right ventricle was reported. The occurrence of a complete encapsulation was not expected and the process of endothelialisation remains unclear. We hypothesized, that a local inflammatory response might be the cause of these findings. The aim of our experimental in-vitro study was to investigate the effect of the Micra™ system and its single components on inflammatory processes. METHODS For this purpose, whole Micra™ pacemakers were incubated in heparin plasma from 25 healthy volunteers for 48 h at 37 °C. Furthermore, 1 g gold, steel, titanium, tungsten and nitinol wires were incubated in heparin plasma for 48 h at 37 °C as well (n = 10). To detect eventual inflammatory processes, interleukin- (IL) 1β, IL-6, and tumor necrosis factor alpha (TNF-α), the chemokine IL-8 were measured using enzyme-linked immunosorbent assay (ELISA). Additionally, the level of transforming growth factor beta 1 (TGF-β1) and vascular endothelial growth factor (VEGF) were analysed. RESULTS ELISA analyses showed that the whole Micra system leads to a significant increase in the inflammatory cytokine IL-6 which correlates with the data gained by the incubation of whole blood with the different wires. In particular, 0.5 g of tungsten showed a significant rise of IL-6 which could also be found for IL-1β and IL-8. CONCLUSIONS The in vitro study of the Micra system showed that the material composition led to an onset of inflammatory processes in whole blood. Consequently, one may speculate that the composition of Micra pacemaker may have a local inflammatory, though subclinical, effects in patients implanted with a Micra™ pacemakers.
Collapse
|
37
|
First in Man: Off-Pump Transapical Transcatheter Aortic Valve Implantation and Mitral Valve Repair. Ann Thorac Surg 2019; 107:e249-e250. [DOI: 10.1016/j.athoracsur.2018.07.062] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2018] [Accepted: 07/10/2018] [Indexed: 10/28/2022]
|
38
|
Congenital Anomalies of Coronary Arteries: A Challenge in Interventional Cardiology. Cardiology 2019; 142:91-92. [DOI: 10.1159/000499537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Accepted: 03/12/2019] [Indexed: 11/19/2022]
|
39
|
[Micra™ leadless pacemaker : Clinical experience and perspectives]. Herzschrittmacherther Elektrophysiol 2018; 29:334-339. [PMID: 30456580 DOI: 10.1007/s00399-018-0592-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Accepted: 09/10/2018] [Indexed: 10/27/2022]
Abstract
Leadless pacemakers have the potential to fundamentally change the field of device therapy. As leads and generator pockets are no longer needed with this technology, many potentially dangerous complications of conventional pacemaker systems like lead fractures, lead endocarditis or pocket infections can be effectively avoided. At present, Micra™ (Medtronic Inc., Minneapolis, MN, USA) is the only commercially available leadless pacemaker. Since its first-in-human implantation in 2013, thousands of these devices have been implanted worldwide. This article presents an overview of the present clinical evidence and future perspectives of this promising new technology.
Collapse
|
40
|
Lipid profile and long-term outcome in premature myocardial infarction. Eur J Clin Invest 2018; 48:e13008. [PMID: 30062727 DOI: 10.1111/eci.13008] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Accepted: 07/28/2018] [Indexed: 12/22/2022]
Abstract
BACKGROUND Premature myocardial infarction (≤40 years) represents a rare disease with a distinct risk factor profile and a lipid phenotype that is characterized by a predominance of elevated triglyceride-rich lipoproteins. So far high-density and low-density lipoproteins remain the primary targets for risk stratification and treatment evaluation in coronary artery disease, but this strategy might be insensitive in patients with premature myocardial infarction. AIM Aim of this study was to investigate the predictive value of different lipid fractions on long-term cardiovascular outcome in patients with premature myocardial infarction. METHODS We prospectively enrolled 102 consecutive AMI survivors (≤40 years) in this prospective multicentre study and investigated the influence of the familial combined hypercholesterolaemia phenotype and a corresponding multimarker panel of different lipid fractions on cardiovascular outcome. RESULTS Total cholesterol, non-HDL cholesterol, remnant cholesterol and Apo B lipoprotein were significantly higher in patients experiencing MACE as compared to those who did not. The familial combined hypercholesterolaemia phenotype was associated with an unfavourable cardiovascular outcome even after adjustment for potential cofounders (adjusted HR 3.04,95% CI, 1.26-7.34, P = 0.013). Remnant cholesterol revealed the strongest association with MACE (adj.HR 1.94, 95%CI. 1.30-2.99, P = 0.001). Interestingly LDL and HDL revealed no significant impact on cardiovascular outcome in this study cohort. CONCLUSION Non-HDL and remnant cholesterol are strongly associated with an unfavourable outcome in patients with premature myocardial infarction and might be the preferred treatment target for lipid-lowering therapy.
Collapse
|
41
|
P4510High-molecular-weight von Willebrand factor multimer ratio for the differentiation between true-severe and pseudo-severe low-flow, low-gradient aortic stenosis. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy563.p4510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
42
|
Reversible impairment of coronary flow reserve in acute myocarditis. Microcirculation 2018; 25:e12491. [PMID: 30027659 DOI: 10.1111/micc.12491] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2018] [Revised: 06/18/2018] [Accepted: 07/13/2018] [Indexed: 01/05/2023]
Abstract
OBJECTIVE Acute myocarditis is accompanied by an impaired coronary microcirculation. These microcirculatory disturbances are not well defined, and data are derived from complex invasive measurements. Therefore, this study aimed to evaluate the inflammation-induced microcirculatory dysfunction including its reversibility and association with markers of inflammation severity (extent of LGE on CMR imaging and laboratory markers of myocardial necrosis) using the noninvasive technique of echocardiographic CFR measurement. METHODS Patients (n = 14) with clinically suspected acute myocarditis in the absence of coronary artery disease were prospectively enrolled, and echocardiographic CFR was determined by measuring peak diastolic coronary blood flow velocity at rest (PDV1) and under adenosine-induced hyperemia (PDV2) at baseline and 3-month follow-up. RESULTS Eight of 14 (57.1%) patients showed an impaired baseline CFR (PDV2/PDV1 < 2). These patients were characterized by higher levels of cardiac troponin T (0.55 ± 0.39 vs 0.18 ± 0.08; P = 0.008) and larger areas of LGE on CMR. At 3-month follow-up, CFR was normal in all patients. CONCLUSION A reversibly impaired coronary microcirculation is a frequent finding in acute myocarditis and is associated with markers of inflammation severity. Echocardiographic CFR measurement represents a feasible and safe method for its assessment.
Collapse
|
43
|
Monocenter Investigation Micra® MRI study (MIMICRY): feasibility study of the magnetic resonance imaging compatibility of a leadless pacemaker system. Europace 2018; 21:137-141. [DOI: 10.1093/europace/euy143] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2018] [Accepted: 05/27/2018] [Indexed: 11/12/2022] Open
|
44
|
Artefacts in 1.5 Tesla and 3 Tesla cardiovascular magnetic resonance imaging in patients with leadless cardiac pacemakers. J Cardiovasc Magn Reson 2018; 20:47. [PMID: 29973228 PMCID: PMC6033226 DOI: 10.1186/s12968-018-0469-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2017] [Accepted: 06/06/2018] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND There are limited data on patients with leadless cardiac pacemakers (LCP) undergoing magnetic resonance imaging. The aim of this prospective, single-center, observational study was to evaluate artefacts on cardiovascular magnetic resonance (CMR) images in patients with LCP. METHODS Fifteen patients with Micra™ LCP, implanted at least 6 weeks prior to CMR scan, were enrolled and underwent either 1.5 Tesla or 3 Tesla CMR imaging. Artefacts were categorized into grade 1 (excellent image quality), grade 2 (good), grade 3 (poor) and grade 4 (non-diagnostic) for each myocardial segment. One patient was excluded because of an incomplete CMR investigation due to claustrophobia. RESULTS LCP caused an arc-shaped artefact (0.99 ± 0.16 cm2) at the right ventricular (RV) apex. Of 224 analyzed myocardial segments of the left ventricle (LV) 158 (70.5%) were affected by grade 1, 27 (12.1%) by grade 2, 17 (7.6%) by grade 3 and 22 (9.8%) by grade 4 artefacts. The artefact burden of grade 3 and 4 artefacts was significantly higher in the 3 Tesla group (3 Tesla vs 1.5 Tesla: 3.7 ± 1.6 vs 1.9 ± 1.4 myocardial segments per patient, p = 0.03). A high artefact burden was particularly observed in the mid anteroseptal, inferoseptal and apical septal myocardial segments of the LV and in the mid and apical segments of the RV. Quantification of LV function and assessment of valves were feasible in all patients. We did not observe any clinical or device-related adverse events. CONCLUSION CMR imaging in patients with LCP is feasible with excellent to good image quality in the majority of LV segments. The artefact burden is comparable small allowing an accurate evaluation of LV function, cardiac structures and valves. However, artefacts in the mid anteroseptal, inferoseptal and apical septal myocardial segments of the LV due to the LCP may impair or even exclude diagnostic evaluation of these segments. Artefacts on CMR images may be reduced by the use of 1.5 Tesla CMR scanners.
Collapse
|
45
|
Abstract
BACKGROUND Randomized controlled trials have yielded conflicting results regarding the ability of beta-blockers to influence perioperative cardiovascular morbidity and mortality. Thus routine prescription of these drugs in unselected patients remains a controversial issue. OBJECTIVES The objective of this review was to systematically analyse the effects of perioperatively administered beta-blockers for prevention of surgery-related mortality and morbidity in patients undergoing any type of surgery while under general anaesthesia. SEARCH METHODS We identified trials by searching the following databases from the date of their inception until June 2013: MEDLINE, Embase , the Cochrane Central Register of Controlled Trials (CENTRAL), Biosis Previews, CAB Abstracts, Cumulative Index to Nursing and Allied Health Literature (CINAHL), Derwent Drug File, Science Citation Index Expanded, Life Sciences Collection, Global Health and PASCAL. In addition, we searched online resources to identify grey literature. SELECTION CRITERIA We included randomized controlled trials if participants were randomly assigned to a beta-blocker group or a control group (standard care or placebo). Surgery (any type) had to be performed with all or at least a significant proportion of participants under general anaesthesia. DATA COLLECTION AND ANALYSIS Two review authors independently extracted data from all studies. In cases of disagreement, we reassessed the respective studies to reach consensus. We computed summary estimates in the absence of significant clinical heterogeneity. Risk ratios (RRs) were used for dichotomous outcomes, and mean differences (MDs) were used for continuous outcomes. We performed subgroup analyses for various potential effect modifiers. MAIN RESULTS We included 88 randomized controlled trials with 19,161 participants. Six studies (7%) met the highest methodological quality criteria (studies with overall low risk of bias: adequate sequence generation, adequate allocation concealment, double/triple-blinded design with a placebo group, intention-to-treat analysis), whereas in the remaining trials, some form of bias was present or could not be definitively excluded (studies with overall unclear or high risk of bias). Outcomes were evaluated separately for cardiac and non-cardiac surgery.CARDIAC SURGERY (53 trials)We found no clear evidence of an effect of beta-blockers on the following outcomes.• All-cause mortality: RR 0.73, 95% CI 0.35 to 1.52, 3783 participants, moderate quality evidence.• Acute myocardial infarction (AMI): RR 1.04, 95% CI 0.71 to 1.51, 3553 participants, moderate quality evidence.• Myocardial ischaemia: RR 0.51, 95% CI 0.25 to 1.05, 166 participants, low quality evidence.• Cerebrovascular events: RR 1.52, 95% CI 0.58 to 4.02, 1400 participants, low quality evidence.• Hypotension: RR 1.54, 95% CI 0.67 to 3.51, 558 participants, low quality evidence.• Bradycardia: RR 1.61, 95% CI 0.97 to 2.66, 660 participants, low quality evidence.• Congestive heart failure: RR 0.22, 95% CI 0.04 to 1.34, 311 participants, low quality evidence.Beta-blockers significantly reduced the occurrence of the following endpoints.• Ventricular arrhythmias: RR 0.37, 95% CI 0.24 to 0.58, number needed to treat for an additional beneficial outcome (NNTB) 29, 2292 participants, moderate quality evidence.• Supraventricular arrhythmias: RR 0.44, 95% CI 0.36 to 0.53, NNTB five, 6420 participants, high quality evidence.• On average, beta-blockers reduced length of hospital stay by 0.54 days (95% CI -0.90 to -0.19, 2450 participants, low quality evidence).NON-CARDIAC SURGERY (35 trials)Beta-blockers significantly increased the occurrence of the following adverse events.• All-cause mortality: RR 1.25, 95% CI 1.00 to 1.57, 11,413 participants, low quality of evidence, number needed to treat for an additional harmful outcome (NNTH) 167.• Hypotension: RR 1.50, 95% CI 1.38 to 1.64, NNTH 16, 10,947 participants, high quality evidence.• Bradycardia: RR 2.23, 95% CI 1.48 to 3.36, NNTH 21, 11,033 participants, moderate quality evidence.We found a potential increase in the occurrence of the following outcomes with the use of beta-blockers.• Cerebrovascular events: RR 1.59, 95% CI 0.93 to 2.71, 9150 participants, low quality evidence.Whereas no clear evidence of an effect was found when all studies were analysed, restricting the meta-analysis to low risk of bias studies revealed a significant increase in cerebrovascular events with the use of beta-blockers: RR 2.09, 95% CI 1.14 to 3.82, NNTH 265, 8648 participants.Beta-blockers significantly reduced the occurrence of the following endpoints.• AMI: RR 0.73, 95% CI 0.61 to 0.87, NNTB 76, 10,958 participants, high quality evidence.• Myocardial ischaemia: RR 0.51, 95% CI 0.34 to 0.77, NNTB nine, 978 participants, moderate quality evidence.• Supraventricular arrhythmias: RR 0.73, 95% CI 0.57 to 0.94, NNTB 112, 8744 participants, high quality evidence.We found no clear evidence of an effect of beta-blockers on the following outcomes.• Ventricular arrhythmias: RR 0.68, 95% CI 0.31 to 1.49, 476 participants, moderate quality evidence.• Congestive heart failure: RR 1.18, 95% CI 0.94 to 1.48, 9173 participants, moderate quality evidence.• Length of hospital stay: mean difference -0.45 days, 95% CI -1.75 to 0.84, 551 participants, low quality evidence. AUTHORS' CONCLUSIONS According to our findings, perioperative application of beta-blockers still plays a pivotal role in cardiac surgery, as they can substantially reduce the high burden of supraventricular and ventricular arrhythmias in the aftermath of surgery. Their influence on mortality, AMI, stroke, congestive heart failure, hypotension and bradycardia in this setting remains unclear.In non-cardiac surgery, evidence shows an association of beta-blockers with increased all-cause mortality. Data from low risk of bias trials further suggests an increase in stroke rate with the use of beta-blockers. As the quality of evidence is still low to moderate, more evidence is needed before a definitive conclusion can be drawn. The substantial reduction in supraventricular arrhythmias and AMI in this setting seems to be offset by the potential increase in mortality and stroke.
Collapse
|
46
|
Economic assessment of traditional surgical intervention versus use of a new innovative radiofrequency based surgical system in device replacements. PLoS One 2018; 13:e0192587. [PMID: 29509774 PMCID: PMC5839556 DOI: 10.1371/journal.pone.0192587] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2017] [Accepted: 01/26/2018] [Indexed: 11/18/2022] Open
Abstract
Introduction Intra-operative complications like mechanical damages to the leads, infections and hematomas during generator replacements of implantable pacemakers and defibrillators contribute to additional costs for hospitals. The aim of this study was to evaluate operation room use, costs and budget impact of generator replacements using either a traditional surgical intervention (TSI) with scissors, scalpel and electrocautery vs. a new radiofrequency energy based surgical system, called PEAK PlasmaBladeTM (PPB). Materials and methods We conducted a retrospective analysis of a population including 508 patients with TSI and 254 patients with PPB who underwent generator replacement at the Kepler University Hospital in Linz or the St. Josef Hospital in Braunau, Austria. The economic analysis included costs of resources used for intra-operative complications (lead damages) and of procedure time for TSI vs. PPB. Results Proportion of males, mean age and type of generator replaced were similar between the two groups. Lead damages occurred significantly more frequent with TSI than with PPB (5.3% and 0.4%; p< 0.001) and the procedure time was significantly longer with TSI than with PPB (47.9±24.9 and 34.1±18.1 minutes; p<0.001). Shorter procedure time and a lower rate of lead damages with PPB resulted in per patient cost savings of €81. Based on estimated 2,700 patients annually undergoing generator replacement in Austria, the use of PPB may translate into cost savings of €219,600 and 621 saved operating facility hours. Conclusion PPB has the potential to minimize the risk of lead damage with more efficient utilization of the operating room. Along with cost savings and improved quality of care, hospitals may use the saved operating room hours to increase the number of daily surgeries.
Collapse
|
47
|
Characterization of Von Willebrand Factor Multimer Structure in Patients With Severe Aortic Stenosis. Clin Appl Thromb Hemost 2017; 24:496-501. [PMID: 29202604 PMCID: PMC6714650 DOI: 10.1177/1076029617744321] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
Acquired von Willebrand syndrome (AVWS) associated with severe aortic stenosis (AS) has been frequently subclassified into a subtype 2A based on the deficiency of high-molecular-weight (HMW) multimers as it is seen in inherited von Willebrand disease (VWD) type 2A. However, the multimeric phenotype of VWD type 2A does not only include an HMW deficiency but also a decrease in intermediate-molecular-weight (IMW) multimers and an abnormal inner triplet band pattern. These additional characteristics have not been evaluated in AVWS associated with severe AS. Therefore, we recruited N = 31 consecutive patients with severe AS and performed a high-resolution Western blot with densitometrical band quantification to characterize the von Willebrand factor (VWF) multimeric structure and reevaluate the AVWS subtype classification. Study patients showed an isolated HMW VWF multimer deficiency without additional abnormalities of the IMW portions and the inner triplet structure in 65%. In conclusion, the multimeric pattern of AVWS associated with severe AS does neither resemble that seen in AVWS type 2A nor that seen in inherited VWD type 2A. Therefore, a subclassification into a type 2A should not be used.
Collapse
|
48
|
|
49
|
In-stent restenosis after interventional treatment of carotid artery stenoses: a long-term follow-up of a single center cohort. Clin Res Cardiol 2017; 106:493-500. [DOI: 10.1007/s00392-017-1078-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Accepted: 01/10/2017] [Indexed: 11/28/2022]
|
50
|
Late renal artery stenosis after percutaneous renal denervation. J Cardiovasc Med (Hagerstown) 2016; 17 Suppl 2:e169-e170. [DOI: 10.2459/jcm.0000000000000095] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|