1
|
Laboratory stewardship perceptions and testing patterns at a pediatric tertiary care center. Lab Med 2024:lmae003. [PMID: 38417046 DOI: 10.1093/labmed/lmae003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/01/2024] Open
Abstract
BACKGROUND Despite stewardship efforts, laboratory testing overuse persists across medicine. OBJECTIVES To understand laboratory stewardship perceptions and testing patterns at a tertiary care pediatric hospital so that we could identify potential improvement opportunities. METHODS An electronic survey exploring laboratory stewardship was sent to all pediatric medicine resident and staff physicians. Laboratory testing data were also assessed for patterns of testing and overuse. RESULTS The survey response rate was 54% (43/80). The results indicated good familiarity with stewardship but poor familiarity with testing specifics (eg, cost). A mobile reference application was the most preferred quality improvement intervention, and online modules were the least desired. Overuse was apparent, with as many as 53% of laboratory tests being repeated within 7 days and only half of repeated tests subsequently yielding abnormal results. CONCLUSIONS Altogether, the data we collated demonstrated poor understanding of laboratory stewardship and substantial repeat testing with few abnormal results. These study findings suggest that laboratory stewardship is lacking at our center, and that multiple improvement opportunities exist.
Collapse
|
2
|
Canadian Society of Clinical Chemists Harmonized Pediatric Lipid Reporting Recommendations for Clinical Laboratories. Can J Cardiol 2024:S0828-282X(24)00071-0. [PMID: 38336003 DOI: 10.1016/j.cjca.2024.01.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 12/20/2023] [Accepted: 01/07/2024] [Indexed: 02/12/2024] Open
Abstract
Detecting dyslipidemia early is important because atherosclerosis originates in childhood and early treatment can improve outcomes. In 2022, the Canadian Cardiovascular Society (CCS)/Canadian Pediatric Cardiology Association (CPCA) published a clinical practice update to detect, evaluate, and manage pediatric dyslipidemia. However, guidance on its translation into clinical laboratories is lacking. The Canadian Society of Clinical Chemists Working Group on Reference Interval Harmonization Lipid Team aims to assist guideline implementation and promote harmonized pediatric lipid reporting across Canada. The 2022 CCS/CPCA clinical practice update, 2011 National Heart, Lung, and Blood Institute integrated guidelines, and new data analysis (Canadian pediatric reference values from the Canadian Laboratory Initiative on Pediatric Reference Intervals [CALIPER] and retrospective patient data from large community laboratories) were incorporated to develop 5 key recommendations. These include recommendations to: (1) offer nonfasting and fasting lipid testing; (2) offer a lipid panel including total cholesterol, low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C), non-HDL-C, and triglycerides, with apolipoprotein B and lipoprotein(a) available as individually orderable tests; (3) flag total cholesterol, LDL-C, and non-HDL-C results ≥ 95th percentile, and HDL-C results < 10th percentile, as recommended by CCS/CPCA/National Heart, Lung, and Blood Institute and validated by CALIPER, and flag apolipoprotein B and nonfasting triglyceride results ≥ 95th percentile on the basis of CALIPER, and do not flag lipoprotein(a) results but mention the adult cutoff in the interpretive comments; (4) implement interpretive comments listed in the current report; and (5) implement the National Institutes of Health LDL-C equation. The Canadian Society of Clinical Chemists Working Group on Reference Interval Harmonization Lipid Team will support clinical laboratories to implement these recommendations using knowledge translation strategies. Harmonizing pediatric lipid reporting across Canadian clinical laboratories will optimize clinical decision-making and improve cardiovascular risk management in youth.
Collapse
|
3
|
Quality standards and internal quality control practices in medical laboratories: an IFCC global survey of member societies. Clin Chem Lab Med 2023; 61:2094-2101. [PMID: 37327359 DOI: 10.1515/cclm-2023-0492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 06/04/2023] [Indexed: 06/18/2023]
Abstract
OBJECTIVES The trueness and precision of clinical laboratory results are ensured through total quality management systems (TQM), which primarily include internal quality control (IQC) practices. However, quality practices vary globally. To understand the current global state of IQC practice and IQC management in relation to TQM the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Global Laboratory Quality (TF-GLQ) conducted a survey of IFCC member countries on IQC practices and management. METHODS The survey included 16 questions regarding IQC and laboratory TQM practices and was distributed to IFCC full and affiliate member countries (n=110). A total of 46 (41.8 %) responses were received from all regions except North America. RESULTS Of the responding countries, 78.3 % (n=36) had legislative regulations or accreditation requirements governing medical laboratory quality standards. However, implementation was not mandatory in 46.7 % (n=21) of responding countries. IQC practices varied considerably with 57.1 % (n=28) of respondents indicating that they run 2 levels of IQC, 66.7 % (n=24) indicating they run IQC every 24 h and 66.7 % (n=28) using assay manufacturer IQC material sources. Only 29.3 % (n=12) of respondents indicated that every medical laboratory in their country has written IQC policies and procedures. By contrast, 97.6 % (n=40) of responding countries indicated they take corrective action and result remediation in the event of IQC failure. CONCLUSIONS The variability in TQM and IQC practices highlights the need for more formal programs and education to standardize and improve TQM in medical laboratories.
Collapse
|
4
|
External quality assessment practices in medical laboratories: an IFCC global survey of member societies. Clin Chem Lab Med 2023; 61:1404-1410. [PMID: 36779362 DOI: 10.1515/cclm-2023-0057] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2023] [Accepted: 01/16/2023] [Indexed: 02/14/2023]
Abstract
OBJECTIVES Clinical laboratory results are required for critical medical decisions, underscoring the importance of quality results. As part of total quality management, external quality assessment (EQA) is a vital component to ensure laboratory accuracy. The goal of this survey was to evaluate the current status of global laboratory quality systems and assess the need for implementation, expansion, or harmonization of EQA programs (EQAP) for Clinical Chemistry and Laboratory Medicine. METHODS The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Global Laboratory Quality (TF-GLQ) conducted a survey of IFCC full and affiliate members (n=110) on laboratory quality practice. A total of 41 (37.3%) countries representing all IFCC regions except North America provided responses about EQA availability and practices. RESULTS All 41 countries perform EQA, 38 reported that their laboratories had EQA policies and procedures, and 39 further act/evaluate unacceptable EQA results. 39 countries indicated they have international and/or national EQAP and 30 use alternative performance assessments. EQA frequency varied among countries. Generally, an EQAP provided the EQA materials (40/41) with four countries indicating that they did not have an EQAP in their country. CONCLUSIONS Globally, most laboratories participate in an EQAP and have defined quality procedures for EQA. There remain gaps in EQA material availability and implementation of EQA as a part of a total laboratory quality system. This survey highlights the need for education, training, and harmonization and will guide efforts of the IFCC TF-GLQ in identifying areas for enhancing global laboratory quality practices.
Collapse
|
5
|
Modifying the Non-Modifiable: Single-Dose Hepatic-Targeted siRNA Leads to Sustained Decreases in Plasma Lp(a). Clin Chem 2022. [DOI: 10.1093/clinchem/hvac130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
|
6
|
Effective interventions to improve the quality of critically high point-of-care glucose meter results. Pract Lab Med 2020; 22:e00184. [PMID: 33145388 PMCID: PMC7596339 DOI: 10.1016/j.plabm.2020.e00184] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Accepted: 10/16/2020] [Indexed: 11/13/2022] Open
Abstract
Objectives Point-of-care testing (POCT) is testing performed outside the traditional laboratory, often at the patient bedside. In hospital settings, blood glucose is the most common POCT. Staff performing POCT are not usually laboratory trained; they are clinical staff with a primary focus on treating patients. Clinical staff find POCT quality assurance (QA) practices burdensome and are often non-compliant. In hospitals within EORLA (Eastern Ontario Regional Laboratories Association), all critically high POCT glucose results must be repeated prior to acting, according to policy. Compliance with this policy is audited regularly. Design and methods: All POCT glucose tests performed in participating sites between January and June 2018 and June and December 2019 were audited for compliance with the critical repeat policy. The discordant repeat rate was also determined for each audit period. Between January and May 2019, there were interventions aimed at improving compliance with the repeat policy. Results Compliance with the critical repeat policy increased from 30 to 57% in 2019 compared to 2018, following nursing education and implementation of notifications on the glucose meters themselves. The rate of discordant repeat results (>20% different from initial) also improved at most sites in 2019 compared to 2018. Nurses cited insufficient cleaning of patient hands prior to initial testing as the primary reason for discordant repeats. Conclusions Operator compliance with POCT QA policies is an ongoing challenge requiring continual audit, feedback and education. A strong POCT multi-disciplinary committee with supports from senior and clinical leadership in an organization are key to improving compliance. Compliance with the policy requiring repeat of all critically high POCT glucose results is audited as a quality indicator. Audits demonstrated a high rate of non-compliance with the critical repeat policy by clinical staff performing POCT. Approximately 25% of critically high glucose results repeated were discordant (>20% different from the initial result) Implementation of meter notifications and nursing education led to significant improvements in compliance at most sites.
Collapse
|
7
|
Multivalent nephrin-Nck interactions define a threshold for clustering and tyrosine-dependent nephrin endocytosis. J Cell Sci 2020; 133:jcs236877. [PMID: 31974115 DOI: 10.1242/jcs.236877] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Accepted: 01/10/2020] [Indexed: 12/17/2022] Open
Abstract
Assembly of signaling molecules into micrometer-sized clusters is driven by multivalent protein-protein interactions, such as those found within the nephrin-Nck (Nck1 or Nck2) complex. Phosphorylation on multiple tyrosine residues within the tail of the nephrin transmembrane receptor induces recruitment of the cytoplasmic adaptor protein Nck, which binds via its triple SH3 domains to various effectors, leading to actin assembly. The physiological consequences of nephrin clustering are not well understood. Here, we demonstrate that nephrin phosphorylation regulates the formation of membrane clusters in podocytes. We also reveal a connection between clustering and endocytosis, which appears to be driven by threshold levels of nephrin tyrosine phosphorylation and Nck SH3 domain signaling. Finally, we expose an in vivo correlation between transient changes in nephrin tyrosine phosphorylation, nephrin localization and integrity of the glomerular filtration barrier during podocyte injury. Altogether, our results suggest that nephrin phosphorylation determines the composition of effector proteins within clusters to dynamically regulate nephrin turnover and podocyte health.
Collapse
|
8
|
Candidate recommendations for protein electrophoresis reporting from the Canadian Society of Clinical Chemists Monoclonal Gammopathy Working Group. Clin Biochem 2018; 51:10-20. [DOI: 10.1016/j.clinbiochem.2017.10.013] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2017] [Revised: 10/18/2017] [Accepted: 10/18/2017] [Indexed: 11/26/2022]
|
9
|
Evaluation of electrochemiluminescence immunoassays for immunosuppressive drugs on the Roche cobas e411 analyzer. F1000Res 2017; 6:1832. [PMID: 29225777 PMCID: PMC5710386 DOI: 10.12688/f1000research.12775.2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/08/2017] [Indexed: 12/21/2022] Open
Abstract
Background: Therapeutic drug monitoring of immunosuppressant drugs are used to monitor drug efficacy and toxicity and to prevent organ transplant rejection. This study evaluates the analytical performance of semi-automated electrochemiluminescence immunoassays (ECLIA) for cyclosporine (CSA), tacrolimus (TAC) and sirolimus (SRL) on the Roche cobas e 411 analyzer at a major transplant hospital to assess method suitability and limitations. Methods: Residual whole blood samples from patients undergoing immunosuppressant therapy were used for evaluation. Imprecision, linearity, functional sensitivity, method comparisons and lot-to-lot comparisons were assessed. Results: Total imprecision ranged from 3.3 to 7.1% for CSA, 3.9 to 9.4% for TAC, and 4.6 to 8.2% for SRL. Linearity was verified from 30.0 to 960.9 μg/L for CSA, from 1.1 to 27.1 μg/L for TAC, and from 0.5 to 32.3 µg/L for SRL. The functional sensitivity met the manufacturer’s claims and was determined to be <6.5 μg/L for CSA, 1.1 μg/L for TAC, and <0.1 µg/L for SRL (CV≤20%). Deming regression analysis of method comparisons with the ARCHITECT immunoassay yielded slopes of 0.917 (95%CI: 0.885-0.949) and r of 0.985 for CSA, 0.938 (95%CI: 0.895-0.981) and r of 0.974 for TAC, and 0.842 (0.810-1.110) and r of 0.982 for SRL. Deming regression analysis of comparisons with the LC–MS/MS method yielded slopes of 1.331 (95%CI: 1.167-1.496) and r of 0.969 for CSA, 0.924 (95%CI: 0.843-1.005) and r of 0.984 for TAC, and 0.971 (95%CI: 0.913-1.030) and r of 0.993 for SRL. Conclusions: The cobas e 411 ECLIA for CSA, TAC, and SRL have acceptable precision, linearity, and functional sensitivity. The method comparisons correlated well with the ARCHITECT immunoassay and LC–MS/MS and is fit for therapeutic drug monitoring
Collapse
|
10
|
Generation of monoclonal antibodies and development of an immunofluorometric assay for the detection of CUZD1 in tissues and biological fluids. Clin Biochem 2017; 50:1168-1174. [PMID: 28746862 DOI: 10.1016/j.clinbiochem.2017.07.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2017] [Revised: 07/21/2017] [Accepted: 07/22/2017] [Indexed: 02/08/2023]
Abstract
BACKGROUND CUB and zona pellucida-like domain-containing protein 1 (CUZD1) was identified as a pancreas-specific protein and was proposed as a candidate biomarker for pancreatic related disorders. CUZD1 protein levels in tissues and biological fluids have not been extensively examined. The purpose of the present study was to generate specific antibodies targeting CUZD1 to assess CUZD1 expression within tissues and biological fluids. METHODS Mouse monoclonal antibodies against CUZD1 were generated and used to perform immunohistochemical analyses and to develop a sensitive and specific enzyme-linked immunosorbent assay (ELISA). CUZD1 protein expression was assessed in various human tissue extracts and biological fluids and in gel filtration chromatography-derived fractions of pancreatic tissue extract, pancreatic juice and recombinant protein. RESULTS Immunohistochemical staining of CUZD1 in pancreatic tissue showed that the protein is localized to the acinar cells and the lumen of the acini. Western blot analysis detected the protein in pancreatic tissue extract and pancreatic juice. The newly developed ELISA measured CUZD1 in high levels in pancreas and in much lower but detectable levels in several other tissues. In the biological fluids tested, CUZD1 expression was detected exclusively in pancreatic juice. The analysis of gel filtration chromatography-derived fractions of pancreatic tissue extract, pancreatic juice and recombinant CUZD1 suggested that the protein exists in high molecular weight protein complexes. CONCLUSION This study describes the development of tools targeting CUZD1 protein, its tissue expression pattern and levels in several biological fluids. These new tools will facilitate future investigations aiming to delineate the role of CUZD1 in physiology and pathobiology.
Collapse
|
11
|
A patient with monoclonal gammopathy-related nephrotic syndrome revealed no electrophoretic "nephrotic pattern" or skewed free light chain ratio. Clin Biochem 2017; 51:110-111. [PMID: 28676334 DOI: 10.1016/j.clinbiochem.2017.06.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Revised: 05/03/2017] [Accepted: 06/28/2017] [Indexed: 11/25/2022]
|
12
|
The Phoenix Rises: The Rebirth of Cancer Immunotherapy. Clin Chem 2017; 63:1190-1195. [PMID: 28515097 DOI: 10.1373/clinchem.2016.267849] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Accepted: 04/11/2017] [Indexed: 11/06/2022]
|
13
|
Novel immunoassays for detection of CUZD1 autoantibodies in serum of patients with inflammatory bowel diseases. ACTA ACUST UNITED AC 2017; 55:1574-1581. [DOI: 10.1515/cclm-2016-1120] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Accepted: 02/21/2017] [Indexed: 02/07/2023]
Abstract
AbstractBackground:Pancreatic autoantibodies (PABs) are detected in patients with inflammatory bowel disease (IBD). Their prevalence is higher in Crohn’s disease (CrD) than in ulcerative colitis (UC). Glycoprotein 2 (GP2) and, more recently, CUB and zona pellucida-like domain-containing protein 1 (CUZD1) have been identified as target autoantigens of PAB. The clinical utility of CUZD1 autoantibodies has only recently been assessed by indirect immunofluorescence (IIF) assays. In this study, we developed and validated novel immunoassays for the detection of CUZD1 autoantibodies.Methods:Recombinant CUZD1 protein was utilized as a solid-phase antigen for the development of two immunoassays for the detection of IgG and IgA CUZD1 autoantibodies. Serum samples from 100 patients with CrD, 100 patients with UC, 129 patients assessed for various autoimmune diseases (vADs) and 50 control individuals were analyzed.Results:Two immunofluorometric assays for the detection of IgG and IgA CUZD1-specific antibodies were developed. CUZD1 autoantibodies were detected in 12.5% (25/200) IBD patients, including 16% of patients with CrD and in 9% of patients with UC (CrD vs. UC, p<0.05), compared with 3.1% (4/129) patients suspected of having vADs (CrD vs. ADs, p<0.05; UC vs. ADs, p=0.08). CUZD1 autoantibody positivity was not found to be related to disease location, age of disease onset or disease phenotype.Conclusions:This is the first study to describe novel IgA and IgG CUZD1 autoantibody enzyme-linked immunosorbent assay. These immunoassays agree well with standard IIF techniques and can be utilized in multicenter studies to investigate the diagnostic and clinical utility of CUZD1 autoantibodies.
Collapse
|
14
|
Abstract
These are exciting times for cancer immunotherapy. After many years of disappointing results, the tide has finally changed and immunotherapy has become a clinically validated treatment for many cancers. Immunotherapeutic strategies include cancer vaccines, oncolytic viruses, adoptive transfer of ex vivo activated T and natural killer cells, and administration of antibodies or recombinant proteins that either costimulate cells or block the so-called immune checkpoint pathways. The recent success of several immunotherapeutic regimes, such as monoclonal antibody blocking of cytotoxic T lymphocyte-associated protein 4 (CTLA-4) and programmed cell death protein 1 (PD1), has boosted the development of this treatment modality, with the consequence that new therapeutic targets and schemes which combine various immunological agents are now being described at a breathtaking pace. In this review, we outline some of the main strategies in cancer immunotherapy (cancer vaccines, adoptive cellular immunotherapy, immune checkpoint blockade, and oncolytic viruses) and discuss the progress in the synergistic design of immune-targeting combination therapies.
Collapse
|
15
|
Analytical evaluation of the BioPlex® 2200 25-OH vitamin D total assay. Clin Biochem 2016; 49:723-725. [PMID: 27112381 DOI: 10.1016/j.clinbiochem.2016.03.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2016] [Revised: 03/16/2016] [Accepted: 03/18/2016] [Indexed: 11/18/2022]
Abstract
BACKGROUND Testing for 25-hydroxyvitamin D (25(OH)D) has increased dramatically over the past decade and several automated immunoassays exist to measure serum 25(OH)D. Here we assess the performance of the recently released automated Bio-Rad BioPlex® 2200 25-OH vitamin D immunoassay, claimed to equally detect 25(OH)D2 and 25(OH)D3, and compare its results against a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and the well-established DiaSorin LIAISON® 25-OH vitamin D total immunoassay. METHODS Imprecision was determined using third party controls over 20days. Linearity over the claimed measuring range was assessed using admixtures of a high and a low patient pool. Correlation between the BioPlex and LC-MS/MS (n=137) or the LIAISON (n=56) was assessed using patient samples with varying amounts of 25(OH)D3 and/or 25(OH)D2. RESULTS The total imprecision was 9.4%, 6.9% and 4.5% at concentrations of 39.4nmol/L, 70.6nmol/L and 242.8nmol/L, respectively. The assay was linear from 33.1-375.0nmol/L with a R(2) of 0.993. Method comparison revealed a strong correlation between the BioPlex assay and LC-MS/MS for samples containing 25(OH)D2 alone (n=5; R(2)=0.999), 25(OH)D3 alone (n=119; R(2)=0.935) and both (n=13; R(2)=0.919). In samples tested by all three methods (n=56), the correlation between the BioPlex and the LIAISON (R(2)=0.853) was poorer than that of the BioPlex and LC-MS/MS (R(2)=0.942). CONCLUSION The BioPlex assay is suitable for the measurement of total serum 25(OH)D. The strong correlation between the BioPlex assay and LC-MS/MS in detecting 25(OH)D2 and 25(OH)D3 provides evidence that the BioPlex assay is capable of the equivalent detection of both forms.
Collapse
|
16
|
Miniaturization: The future of laboratory medicine. Clin Biochem 2016; 49:2-3. [DOI: 10.1016/j.clinbiochem.2015.11.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2015] [Revised: 11/10/2015] [Accepted: 11/12/2015] [Indexed: 10/22/2022]
|
17
|
Abstract
PURPOSE Pancreatic ductal adenocarcinoma (PDAC) is a significant cause of cancer mortality. Carbohydrate antigen 19.9 (CA19.9), the only tumor marker available to detect and monitor PDAC, is not sufficiently sensitive and specific to consistently differentiate early cancer from benign disease. In this study, we aimed to validate recently discovered serum protein biomarkers for the early detection of PDAC and ultimately develop a biomarker panel that could discriminate PDAC from other benign disease better than the existing marker CA19.9. PATIENTS AND METHODS We performed a retrospective blinded evaluation of 400 serum samples collected from individuals recruited on a consecutive basis. The sample population consisted of 250 individuals with PDAC at various stages, 130 individuals with benign conditions and 20 healthy individuals. The serum levels of each biomarker were determined by ELISAs or automated immunoassay. RESULTS By randomly splitting matched samples into a training (n = 186) and validation (n = 214) set, we were able to develop and validate a biomarker panel consisting of CA19.9, CA125, and LAMC2 that significantly improved the performance of CA19.9 alone. Improved discrimination was observed in the validation set between all PDAC and benign conditions (AUCCA19.9 = 0.80 vs. AUCCA19.9+CA125+LAMC2 = 0.87; P < 0.005) as well as between early-stage PDAC and benign conditions (AUCCA19.9 = 0.69 vs. AUCCA19.9+CA125+LAMC2 = 0.76; P < 0.05) and between early-stage PDAC and chronic pancreatitis (CP; AUCCA19.9 = 0.59 vs. AUCCA19.9+CA125+LAMC2 = 0.74; P < 0.05). CONCLUSIONS The data demonstrate that a serum protein biomarker panel consisting of CA125, CA19.9, and LAMC2 is able to significantly improve upon the performance of CA19.9 alone in detecting PDAC.
Collapse
|
18
|
Comparison of anti-dsDNA measurements between BioPlex® 2200 and Farr radioimmunoassay: Longitudinal monitoring in systemic lupus erythematosus (SLE). Clin Biochem 2014. [DOI: 10.1016/j.clinbiochem.2014.06.055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
19
|
False biomarker discovery due to reactivity of a commercial ELISA for CUZD1 with cancer antigen CA125. Clin Chem 2013; 60:381-8. [PMID: 24097894 DOI: 10.1373/clinchem.2013.215236] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
BACKGROUND By using proteomics and bioinformatics, we have previously identified a group of highly pancreas-specific proteins as candidate pancreatic ductal adenocarcinoma (PDAC) biomarkers. With the use of commercially available ELISAs, the performance of some of these candidates was initially evaluated in a relatively small serum cohort (n = 100 samples). This phase revealed that CUB and zona pellucida-like domains protein 1 (CUZD1) may represent a new, promising PDAC biomarker. METHODS We performed detailed experiments to investigate the specificity of the commercial CUZD1 ELISA assay. CUZD1 was expressed in house in both bacteria and yeast expression systems. Recombinant CUZD1 and biological samples containing CUZD1, as well as commercial CUZD1 ELISA standards, were analyzed by Western blot, size exclusion HPLC, and mass spectrometry (LC-MS Orbitrap). RESULTS We confirmed that instead of CUZD1, the commercial assay is recognizing a nonhomologous, known cancer antigen [cancer antigen 125 (CA125)]. CONCLUSIONS We conclude that poor characterization of commercial ELISA assays is a factor that could lead to false biomarker discovery. To our knowledge, this is the first report documenting that a commercial ELISA marketed for one analyte (CUZD1) may, in fact, recognize a different, nonhomologous antigen (CA125).
Collapse
|
20
|
Validation of four candidate pancreatic cancer serological biomarkers that improve the performance of CA19.9. BMC Cancer 2013; 13:404. [PMID: 24007603 PMCID: PMC3847832 DOI: 10.1186/1471-2407-13-404] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2013] [Accepted: 08/29/2013] [Indexed: 12/11/2022] Open
Abstract
Background The identification of new serum biomarkers with high sensitivity and specificity is an important priority in pancreatic cancer research. Through an extensive proteomics analysis of pancreatic cancer cell lines and pancreatic juice, we previously generated a list of candidate pancreatic cancer biomarkers. The present study details further validation of four of our previously identified candidates: regenerating islet-derived 1 beta (REG1B), syncollin (SYCN), anterior gradient homolog 2 protein (AGR2), and lysyl oxidase-like 2 (LOXL2). Methods The candidate biomarkers were validated using enzyme-linked immunosorbent assays in two sample sets of serum/plasma comprising a total of 432 samples (Sample Set A: pancreatic ductal adenocarcinoma (PDAC, n = 100), healthy (n = 92); Sample Set B: PDAC (n = 82), benign (n = 41), disease-free (n = 47), other cancers (n = 70)). Biomarker performance in distinguishing PDAC from each control group was assessed individually in the two sample sets. Subsequently, multiparametric modeling was applied to assess the ability of all possible two and three marker panels in distinguishing PDAC from disease-free controls. The models were generated using sample set B, and then validated in Sample Set A. Results Individually, all markers were significantly elevated in PDAC compared to healthy controls in at least one sample set (p ≤ 0.01). SYCN, REG1B and AGR2 were also significantly elevated in PDAC compared to benign controls (p ≤ 0.01), and AGR2 was significantly elevated in PDAC compared to other cancers (p < 0.01). CA19.9 was also assessed. Individually, CA19.9 showed the greatest area under the curve (AUC) in receiver operating characteristic (ROC) analysis when compared to the tested candidates; however when analyzed in combination, three panels (CA19.9 + REG1B (AUC of 0.88), CA19.9 + SYCN + REG1B (AUC of 0.87) and CA19.9 + AGR2 + REG1B (AUC of 0.87)) showed an AUC that was significantly greater (p < 0.05) than that of CA19.9 alone (AUC of 0.82). In a comparison of early-stage (Stage I-II) PDAC to disease free controls, the combination of SYCN + REG1B + CA19.9 showed the greatest AUC in both sample sets, (AUC of 0.87 and 0.92 in Sets A and B, respectively). Conclusions Additional serum biomarkers, particularly SYCN and REG1B, when combined with CA19.9, show promise as improved diagnostic indicators of pancreatic cancer, which therefore warrants further validation.
Collapse
|
21
|
Laminin, gamma 2 (LAMC2): a promising new putative pancreatic cancer biomarker identified by proteomic analysis of pancreatic adenocarcinoma tissues. Mol Cell Proteomics 2013; 12:2820-32. [PMID: 23798558 DOI: 10.1074/mcp.m112.023507] [Citation(s) in RCA: 74] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
In pancreatic cancer, the incidence and mortality curves coincide. One major reason for this high mortality rate in pancreatic ductal adenocarcinoma (PDAC) patients is the dearth of effective diagnostic, prognostic, and disease-monitoring biomarkers. Unfortunately, existing tumor markers, as well as current imaging modalities, are not sufficiently sensitive and/or specific for early-stage diagnosis. There is, therefore, an urgent need for improved serum markers of the disease. Herein, we performed Orbitrap® mass spectrometry proteomic analysis of four PDAC tissues and their adjacent benign tissues and identified a total of 2190 nonredundant proteins. Sixteen promising candidates were selected for further scrutiny using a systematic scoring algorithm. Our preliminary serum verification of the top four candidates (DSP, LAMC2, GP73, and DSG2) in 20 patients diagnosed with pancreatic cancer and 20 with benign pancreatic cysts, showed a significant (p < 0.05) elevation of LAMC2 in pancreatic cancer serum. Extensive validation of LAMC2 in healthy, benign, and PDAC sera from geographically diverse cohorts (n = 425) (Japan, Europe, and USA) demonstrated a significant increase in levels in early-stage PDAC compared with benign diseases. The sensitivity of LAMC2 was comparable to CA19.9 in all data sets, with an AUC value greater than 0.85 in discriminating healthy patients from early-stage PDAC patients. LAMC2 exhibited diagnostic complementarity with CA19.9 by showing significant (p < 0.001 in two out of three cohorts) elevation in PDAC patients with clinically low CA19.9 levels.
Collapse
|
22
|
Strategies for discovering novel pancreatic cancer biomarkers. J Proteomics 2012; 81:126-34. [PMID: 23026552 DOI: 10.1016/j.jprot.2012.09.025] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2012] [Revised: 08/17/2012] [Accepted: 09/23/2012] [Indexed: 12/20/2022]
Abstract
Pancreatic ductal adenocarcinoma (PDAC) is the fourth leading cause of cancer-related deaths in both men and women in Canada and the United States and has the most dismal survival rates among any solid malignancy. Most patients are diagnosed with pancreatic cancer once the disease has progressed into an advanced or metastatic stage, making the only curative approach of resection surgery impossible. The persistent delayed or missed diagnosis of pancreatic cancer can be attributed to the absence of early symptoms and the lack of efficient non-invasive screening or diagnostic tests in clinical practice. Given that earlier diagnosis is critical for ameliorating patients' survival rates, there is an urgent need for biomarkers with enough sensitivity and specificity to help diagnose pancreatic cancer early. Serological biomarkers provide a minimally invasive and efficient way of detecting pancreatic cancer, however, there is currently no marker with sufficient diagnostic sensitivity and specificity to identify early cancer patients. This review focuses on the classical tumor markers for PDAC as well as emerging markers. In addition, we will discuss an integrative proteomic approach used in our lab to identify a panel of biomarkers that have the potential to allow the early detection of PDAC.This article is part of a Special Issue entitled: From protein structures to clinical applications.
Collapse
|
23
|
Abstract
BACKGROUND Protein cancer biomarkers serve multiple clinical purposes, both early and late, during disease progression. The search for new and better biomarkers has become an integral component of contemporary cancer research. However, the number of new biomarkers cleared by the US Food and Drug Administration has declined substantially over the last 10 years, raising concerns regarding the efficiency of the biomarker-development pipeline. CONTENT We describe different clinical uses of cancer biomarkers and their performance requirements. We also present examples of protein cancer biomarkers currently in clinical use and their limitations. The major barriers that candidate biomarkers need to overcome to reach the clinic are addressed. Finally, the long and arduous journey of a protein cancer biomarker from the bench to the clinic is outlined with an example. SUMMARY The journey of a protein biomarker from the bench to the clinic is long and challenging. Every step needs to be meticulously planned and executed to succeed. The history of clinically useful biomarkers suggests that at least a decade is required for the transition of a marker from the bench to the bedside. Therefore, it may be too early to expect that the new technological advances will catalyze the anticipated biomarker revolution any time soon.
Collapse
|
24
|
Pediatric reference intervals for 28 chemistries and immunoassays on the Roche cobas 6000 analyzer--a CALIPER pilot study. Clin Biochem 2010; 43:1045-50. [PMID: 20501329 DOI: 10.1016/j.clinbiochem.2010.05.008] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2010] [Revised: 05/13/2010] [Accepted: 05/16/2010] [Indexed: 10/19/2022]
Abstract
OBJECTIVE The aim of this study was to determine age- and sex-specific pediatric reference intervals for 28 analytes on the Roche cobas 6000 analyzer. DESIGN AND METHODS The study was conducted at the Hospital for Sick Children in Toronto, Canada. Approximately 600 outpatient samples from a pediatric population deemed to be metabolically stable were subdivided into five age classes ranging from 0 to 20 years of age and further partitioned by gender. Reference intervals were established, after removal of samples significantly affected by hemolysis, icterus and lipemia and outlier exclusion, using the Robust statistical method to obtain the 2.5th and 97.5th percentiles. RESULTS Age (birth to 20 years of age) and gender-appropriate pediatric reference intervals for 28 analytes are reported. CONCLUSIONS These reference intervals provide the basis for clinical interpretation of laboratory results using the Roche cobas 6000 analyzer or related instrumentation/methods, provided adequate reference interval verification studies are performed.
Collapse
|
25
|
Abstract
Within the glomerulus, the scaffolding protein nephrin bridges the actin-rich foot processes that extend from adjacent podocytes to form the slit diaphragm. Mutations affecting a number of slit diaphragm proteins, including nephrin, cause glomerular disease through rearrangement of the actin cytoskeleton and disruption of the filtration barrier. We recently established that the Nck family of Src homology 2 (SH2)/SH3 cytoskeletal adaptor proteins can mediate nephrin-dependent actin reorganization. Formation of foot processes requires expression of Nck in developing podocytes, but it is unknown whether Nck maintains podocyte structure and function throughout life. Here, we used an inducible transgenic strategy to delete Nck expression in adult mouse podocytes and found that loss of Nck expression rapidly led to proteinuria, glomerulosclerosis, and altered morphology of foot processes. We also found that podocyte injury reduced phosphorylation of nephrin in adult kidneys. These data suggest that Nck is required to maintain adult podocytes and that phosphotyrosine-based interactions with nephrin may occur in foot processes of resting, mature podocytes.
Collapse
|
26
|
Non-canonical Interaction of Phosphoinositides with Pleckstrin Homology Domains of Tiam1 and ArhGAP9. J Biol Chem 2007; 282:13864-74. [PMID: 17339315 DOI: 10.1074/jbc.m700505200] [Citation(s) in RCA: 79] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Pleckstrin homology (PH) domains are phosphoinositide (PI)-binding modules that target proteins to membrane surfaces. Here we define a family of PH domain proteins, including Tiam1 and ArhGAP9, that demonstrates specificity for PI(4,5)P(2), as well as for PI(3,4,5)P(3) and PI(3,4)P(2), the products of PI 3-kinase. These PH domain family members utilize a non-canonical phosphoinositide binding pocket related to that employed by beta-spectrin. Crystal structures of the PH domain of ArhGAP9 in complex with the headgroups of Ins(1,3,4)P(3), Ins(1,4,5)P(3), and Ins(1,3,5)P(3) reveal how two adjacent phosphate positions in PI(3,4)P(2), PI(4,5)P(2), and PI(3,4,5)P(3) are accommodated through flipped conformations of the bound phospholipid. We validate the non-canonical site of phosphoinositide interaction by showing that binding pocket mutations, which disrupt phosphoinositide binding in vitro, also disrupt membrane localization of Tiam1 in cells. We posit that the diversity in PI interaction modes displayed by PH domains contributes to their versatility of use in biological systems.
Collapse
|
27
|
Determination of the Plk4/Sak consensus phosphorylation motif using peptide spots arrays. FEBS Lett 2006; 581:77-83. [PMID: 17174311 DOI: 10.1016/j.febslet.2006.11.080] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2006] [Revised: 11/27/2006] [Accepted: 11/29/2006] [Indexed: 11/22/2022]
Abstract
The family of polo like kinases (Plks) regulate cell cycle progression through key functional roles in mitosis. While the four mammalian family members, Plk1-4, share overlapping functions, each member possesses unique functions that may be dictated in part by their ability to phosphorylate different substrates. Numerous cellular substrates for Plk1, 2, and 3 have been characterized, but the protein targets for Plk4/Sak remain unknown. We have purified the kinase domain of Sak and demonstrated that it has robust kinase activity in vitro. Using in vitro kinase assays on peptide spots arrays, we determined the consensus phosphorylation motif for Sak to be yen-[Ile/Leu/Val]-Ser/Thr-phi-phi-X- yen/Pro (where phi denotes a large hydrophobic residue, yen is a charged residue dependent on the context of the surrounding sequence, and residues in brackets are unfavoured). This consensus phosphorylation motif differs from that of Plk1, and provides a basis for future studies to identify in vivo substrates of Sak.
Collapse
|
28
|
Nck adaptor proteins link nephrin to the actin cytoskeleton of kidney podocytes. Nature 2006; 440:818-23. [PMID: 16525419 DOI: 10.1038/nature04662] [Citation(s) in RCA: 364] [Impact Index Per Article: 20.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2006] [Accepted: 02/21/2006] [Indexed: 12/27/2022]
Abstract
The glomerular filtration barrier in the kidney is formed in part by a specialized intercellular junction known as the slit diaphragm, which connects adjacent actin-based foot processes of kidney epithelial cells (podocytes). Mutations affecting a number of slit diaphragm proteins, including nephrin (encoded by NPHS1), lead to renal disease owing to disruption of the filtration barrier and rearrangement of the actin cytoskeleton, although the molecular basis for this is unclear. Here we show that nephrin selectively binds the Src homology 2 (SH2)/SH3 domain-containing Nck adaptor proteins, which in turn control the podocyte cytoskeleton in vivo. The cytoplasmic tail of nephrin has multiple YDxV sites that form preferred binding motifs for the Nck SH2 domain once phosphorylated by Src-family kinases. We show that this Nck-nephrin interaction is required for nephrin-dependent actin reorganization. Selective deletion of Nck from podocytes of transgenic mice results in defects in the formation of foot processes and in congenital nephrotic syndrome. Together, these findings identify a physiological signalling pathway in which nephrin is linked through phosphotyrosine-based interactions to Nck adaptors, and thus to the underlying actin cytoskeleton in podocytes. Simple and widely expressed SH2/SH3 adaptor proteins can therefore direct the formation of a specialized cellular morphology in vivo.
Collapse
|