1
|
Filtering efficiency model that includes the statistical randomness of non-woven fiber layers in facemasks. Sep Purif Technol 2022; 282:120049. [PMID: 34744488 PMCID: PMC8558106 DOI: 10.1016/j.seppur.2021.120049] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Revised: 10/18/2021] [Accepted: 10/28/2021] [Indexed: 12/15/2022]
Abstract
Facemasks have become important tools to fight virus spread during the recent COVID-19 pandemic, but their effectiveness is still under debate. We present a computational model to predict the filtering efficiency of an N95-facemask, consisting of three non-woven fiber layers with different particle capturing mechanisms. Parameters such as fiber layer thickness, diameter distribution, and packing density are used to construct two-dimensional cross-sectional geometries. An essential and novel element is that the polydisperse fibers are positioned randomly within a simulation domain, and that the simulation is repeated with different random configurations. This strategy is thought to give a more realistic view of practical facemasks compared to existing analytical models that mostly assume homogeneous fiber beds of monodisperse fibers. The incompressible Navier-Stokes and continuity equations are used to solve the velocity field for various droplet-laden air inflow velocities. Droplet diameters are ranging from 10 nm to 1.0 µm, which covers the size range from the SARS-CoV-2 virus to the large virus-laden airborne droplets. Air inflow velocities varying between 0.1 m·s-1 to 10 m·s-1 are considered, which are typically encountered during expiratory events like breathing, talking, and coughing. The presented model elucidates the different capturing efficiencies (i.e., mechanical and electrostatic filtering) of droplets as a function of their diameter and air inflow velocity. Simulation results are compared to analytical models and particularly compare well with experimental results from literature. Our numerical approach will be helpful in finding new directions for anti-viral facemask optimization.
Collapse
|
2
|
Tuning the catalytic acidity in Al 2O 3 nanofibers with mordenite nanocrystals for dehydration reactions. Catal Sci Technol 2022; 12:4243-4254. [PMID: 35873718 PMCID: PMC9252259 DOI: 10.1039/d2cy00143h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 05/10/2022] [Indexed: 11/21/2022]
Abstract
The chemical and structural properties of Al2O3 are tuned for dehydration reactions. The synergy between the structured Al2O3 shaped as nanofiber and the acid site nature of the zeolite mordenite in the nanofiber improves the dehydration reaction.
Collapse
|
3
|
A wafer-scale fabrication method for three-dimensional plasmonic hollow nanopillars. NANOSCALE ADVANCES 2021; 3:4926-4939. [PMID: 34485816 PMCID: PMC8386417 DOI: 10.1039/d1na00316j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Accepted: 07/07/2021] [Indexed: 06/13/2023]
Abstract
Access to nanofabrication strategies for crafting three-dimensional plasmonic structures is limited. In this work, a fabrication strategy to produce 3D plasmonic hollow nanopillars (HNPs) using Talbot lithography and I-line photolithography is introduced. This method is named subtractive hybrid lithography (SHL), and permits intermixed usage of nano-and-macroscale patterns. Sputter-redeposition of gold (Au) on the SHL resist pattern yields large areas of dense periodic Au-HNPs. These Au-HNPs are arranged in a square unit cell with a 250 nm pitch. The carefully controlled fabrication process resulted in Au-HNPs with nanoscale dimensions over the Au-HNP dimensions such as an 80 ± 2 nm thick solid base with a 133 ± 4 nm diameter, and a 170 ± 10 nm high nano-rim with a 14 ± 3 nm sidewall rim-thickness. The plasmonic optical response is assessed with FDTD-modeling and reveals that the highest field enhancement is at the top of the hollow nanopillar rim. The modeled field enhancement factor (EF) is compared to the experimental analytical field enhancement factor, which shows to pair up with ca. 103 < EF < 104 and ca. 103 < EF < 105 for excitation wavelengths of 633 and 785 nm. From a broader perspective, our results can stimulate the use of Au-HNPs in the fields of plasmonic sensors and spectroscopy.
Collapse
|
4
|
Morphology of single picosecond pulse subsurface laser-induced modifications of sapphire and subsequent selective etching. OPTICS EXPRESS 2018; 26:29283-29295. [PMID: 30470094 DOI: 10.1364/oe.26.029283] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Accepted: 10/04/2018] [Indexed: 06/09/2023]
Abstract
The effect of 1030nm single picosecond pulsed laser-induced modification of the bulk of crystalline sapphire using a combined process of laser amorphization and selective wet chemical etching is studied. Pulse durations of more than 1 picosecond are not commonly used for this subsurface process. We examine the effect of 7 picosecond pulses on the morphology of the unetched, as well as etched, single pulse modifications, showing the variation of shape and size when varying the pulse energy and the depth of processing. In addition, a qualitative analysis of the material transformation after irradiation is provided as well as an analysis of cracking phenomena. Finally, a calculated laser intensity profile inside sapphire, using the Point Spread Function (PSF), is compared to the shape of the modifications. This comparison is employed to calculate the intensity threshold leading to amorphization, which equals 2.5⋅1014 ± 0.4⋅1014 W/cm2.
Collapse
|
5
|
|
6
|
Pattern Formation by Staphylococcus epidermidis via Droplet Evaporation on Micropillars Arrays at a Surface. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2016; 32:7159-69. [PMID: 27341165 DOI: 10.1021/acs.langmuir.6b01658] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
We evaluate the effect of epoxy surface structuring on the evaporation of water droplets containing Staphylococcus epidermidis (S. epidermidis). During evaporation, droplets with S. epidermidis cells yield to complex wetting patterns such as the zipping-wetting1-3 and the coffee-stain effects. Depending on the height of the microstructure, the wetting fronts propagate circularly or in a stepwise manner, leading to the formation of octagonal or square-shaped deposition patterns.4,5 We observed that the shape of the dried droplets has considerable influence on the local spatial distribution of S. epidermidis deposited between micropillars. These changes are attributed to an unexplored interplay between the zipping-wetting1 and the coffee-stain6 effects in polygonally shaped droplets containing S. epidermidis. Induced capillary flows during evaporation of S. epidermidis are modeled with polystyrene particles. Bacterial viability measurements for S. epidermidis show high viability of planktonic cells, but low biomass deposition on the microstructured surfaces. Our findings provide insights into design criteria for the development of microstructured surfaces on which bacterial propagation could be controlled, limiting the use of biocides.
Collapse
|
7
|
Abstract
The global threat of antimicrobial resistance is driving an urgent need for novel antimicrobial strategies. Functional surfaces are essential to prevent spreading of infection and reduce surface contamination. In this study we have fabricated and characterized multiscale-functional nanotopographies with three levels of functionalization: (1) nanostructure topography in the form of silicon nanowires, (2) covalent chemical modification with (3-aminopropyl)triethoxysilane, and (3) incorporation of chlorhexidine digluconate. Cell viability assays were carried out on two model microorganisms E. coli and S. aureus over these nanotopographic surfaces. Using SEM we have identified two growth modes producing distinctive multicellular structures, i.e. in plane growth for E. coli and out of plane growth for S. aureus. We have also shown that these chemically modified SiNWs arrays are effective in reducing the number of planktonic and surface-attached microorganisms.
Collapse
|
8
|
Abstract
There is an ever-increasing demand for data to be embedded in our environment at ever-decreasing temporal and spatial scales. Whilst current communication and storage technologies generally exploit the electromagnetic properties of media, chemistry offers us a new alternative for nanoscale signaling using molecules as messengers with high information content. Biological systems effectively overcome the challenges of chemical communication using highly specific biosynthetic pathways for signal generation together with specialized protein receptors and nervous systems. Here we consider a new approach for information transmission based upon nature's quintessential example of infochemical communication, the moth pheromone system. To approach the sensitivity, specificity and versatility of infochemical communication seen in nature, we describe an array of biologically-inspired technologies for the production, transmission, detection, and processing of molecular signals. We show how it is possible to implement each step of the moth pheromone pathway for biosynthesis, transmission, receptor protein binding/transduction, and antennal lobe processing of monomolecular and multimolecular signals. For each implemented step, we discuss the value, current limitations, and challenges for the future development and integration of infochemical communication technologies. Together, these building blocks provide a starting point for future technologies that can utilize programmable emission and detection of multimolecular information for a new and robust means of communicating chemical information.
Collapse
|
9
|
Sonochemical and high-speed optical characterization of cavitation generated by an ultrasonically oscillating dental file in root canal models. ULTRASONICS SONOCHEMISTRY 2014; 21:324-335. [PMID: 23735893 DOI: 10.1016/j.ultsonch.2013.03.001] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2012] [Revised: 02/25/2013] [Accepted: 03/02/2013] [Indexed: 06/02/2023]
Abstract
Ultrasonically Activated Irrigation makes use of an ultrasonically oscillating file in order to improve the cleaning of the root canal during a root canal treatment. Cavitation has been associated with these oscillating files, but the nature and characteristics of the cavitating bubbles were not yet fully elucidated. Using sensitive equipment, the sonoluminescence (SL) and sonochemiluminescence (SCL) around these files have been measured in this study, showing that cavitation occurs even at very low power settings. Luminol photography and high-speed visualizations provided information on the spatial and temporal distribution of the cavitation bubbles. A large bubble cloud was observed at the tip of the files, but this was found not to contribute to SCL. Rather, smaller, individual bubbles observed at antinodes of the oscillating file with a smaller amplitude were leading to SCL. Confinements of the size of bovine and human root canals increased the amount of SL and SCL. The root canal models also showed the occurrence of air entrainment, resulting in the generation of stable bubbles, and of droplets, near the air-liquid interface and leading eventually to a loss of the liquid.
Collapse
|
10
|
Abstract
Organised nanotopography mimicking the natural extracellular matrix can be used to control morphology, cell motility, and differentiation. However, it is still unknown how specific cell types react with specific patterns. Both initial adhesion and preferential cell migration may be important to initiate and increase cell locomotion and coverage with cells, and thus achieve an enhanced wound healing response around an implantable material. Therefore, the aim of this study was to evaluate how MC3T3-E1 osteoblast initial adhesion and directional migration are influenced by nanogrooves with pitches ranging from 150 nm up to 1000 nm. In this study, we used a multi-patterned substrate with five different groove patterns and a smooth area with either a concentric or radial orientation. Initial cell adhesion measurements after 10 s were performed using atomic force spectroscopy-assisted single-cell force spectroscopy, and demonstrated that nascent cell adhesion was highly induced by a 600 nm pitch and reduced by a 150 nm pitch. Addition of RGD peptide significantly reduced adhesion, indicating that integrins and cell adhesive proteins (e.g. fibronectin or vitronectin) are key factors in specific cell adhesion on nanogrooved substrates. Also, cell migration was highly dependent on the groove pitch; the highest directional migration parallel to the grooves was observed on a 600 nm pitch, whereas a 150 nm pitch restrained directional cell migration. From this study, we conclude that grooves with a pitch of 600 nm may be favourable to enhance fast wound closure, thereby promoting tissue regeneration.
Collapse
|
11
|
Submicron-patterning of bulk titanium by nanoimprint lithography and reactive ion etching. NANOTECHNOLOGY 2012; 23:065306. [PMID: 22248677 DOI: 10.1088/0957-4484/23/6/065306] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Nanopatterns on titanium may enhance endosseous implant biofunctionality. To enable biological studies to prove this hypothesis, we developed a scalable method of fabricating nanogrooved titanium substrates. We defined nanogrooves by nanoimprint lithography (NIL) and a subsequent pattern transfer to the surface of ASTM grade 2 bulk titanium applying a soft-mask for chlorine-based reactive ion etching (RIE). With respect to direct write lithographic techniques the method introduced here is fast and capable of delivering uniformly patterned areas of at least 4 cm(2). A dedicated silicon nanostamp process has been designed to generate the required thickness of the soft-mask for the NIL-RIE pattern transfer. Stamps with pitch sizes from 1000 nm down to 300 nm were fabricated using laser interference lithography (LIL) and deep cryogenic silicon RIE. Although silicon nanomachining was proven to produce smaller pitch sizes of 200 nm and 150 nm respectively, successful pattern transfer to titanium was only possible down to a pitch of 300 nm. Hence, the smallest nanogrooves have a width of 140 nm. An x-ray photoelectron spectroscopy study showed that only very few contaminations arise from the fabrication process and a cytotoxicity assay on the nanopatterned surfaces confirmed that the obtained nanogrooved titanium specimens are suitable for in vivo studies in implantology research.
Collapse
|
12
|
Optimization of stripline-based microfluidic chips for high-resolution NMR. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2009; 201:175-185. [PMID: 19786359 DOI: 10.1016/j.jmr.2009.09.007] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2009] [Revised: 08/26/2009] [Accepted: 09/04/2009] [Indexed: 05/28/2023]
Abstract
We here report on the optimization, fabrication and experimental characterization of a stripline-based microfluidic NMR probe, realized in a silicon substrate. The stripline geometry was modelled in respect of rf-homogeneity, sensitivity and spectral resolution. Using these models, optimal dimensional ratios were found, which hold for every sample size. Based on the optimized parameters, a simple integrated stripline-based microfluidic chip was realized. The fabrication of this chip is described in detail. We achieved a sensitivity of 0.47 nmol/square root(Hz) and a resolution of 0.7 Hz. The rf-homogeneity (A(810 degrees)/A(90 degrees)) was 76% and was proved to be suitable for 2D-NMR analysis of glucose.
Collapse
|
13
|
|
14
|
Characterization of porous silicon integrated in liquid chromatography chips. LAB ON A CHIP 2009; 9:456-463. [PMID: 19156296 DOI: 10.1039/b812301b] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Properties of porous silicon which are relevant for use of the material as a stationary phase in liquid chromatography chips, like porosity, pore size and specific surface area, were determined with high-resolution SEM and N(2) adsorption-desorption isotherms. For the anodization conditions investigated, porosity is between 20 and 60%, pore sizes between 2 and 5 nm and specific surface area between 130 and 410 m(2)/cm(3). It was established that under identical anodization conditions, porous layer formation is 10-15% slower on micromachined pillars than on flat substrates, and depends on geometrical parameters like pillar diameter and height and interpillar spacing. In microchannels containing pillars with a porous silicon shell, chromatographic experiments on a coumarin dye mixture were performed, which in comparison with non-porous pillars showed a significant increase of the retention factors, resulting from the large internal surface of the porous pillars. The increased relative retention of one of the coumarin dyes, C480, could be correlated quantitatively with the measured internal surface of the porous layer. Due to the small pore size, these porous shell columns are particularly suitable for analytical or preparative separation of low-molecular weight molecules, with applications in metabolomics, food quality control, or medical diagnostics.
Collapse
|
15
|
Quantification of electrical field-induced flow reversal in a microchannel. LAB ON A CHIP 2008; 8:945-949. [PMID: 18497916 DOI: 10.1039/b802800a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
We characterize the electroosmotic flow in a microchannel with field effect flow control. High resolution measurements of the flow velocity, performed by micro particle image velocimetry, evidence the flow reversal induced by a local modification of the surface charge due to the presence of the gate. The shape of the microchannel cross-section is accurately extracted from these measurements. Experimental velocity profiles show a quantitative agreement with numerical results accounting for this exact shape. Analytical predictions assuming a rectangular cross-section are found to give a reasonable estimate of the velocity far enough from the walls.
Collapse
|
16
|
High-resolution liquid- and solid-state nuclear magnetic resonance of nanoliter sample volumes using microcoil detectors. J Chem Phys 2008; 128:052202. [DOI: 10.1063/1.2833560] [Citation(s) in RCA: 117] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
|
17
|
Stripline probes for nuclear magnetic resonance. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2007; 189:104-13. [PMID: 17890116 DOI: 10.1016/j.jmr.2007.08.019] [Citation(s) in RCA: 71] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2007] [Revised: 08/24/2007] [Accepted: 08/31/2007] [Indexed: 05/17/2023]
Abstract
A novel route towards chip integrated NMR analysis is evaluated. The basic element in the design is a stripline RF 'coil' which can be defined in a single layer lithographic process and which is fully scalable to smaller dimensions. The sensitivity of such a planar structure can be superior to that of a conventional 3D helix. The basic properties, such as RF field strength, homogeneity and susceptibility broadening are discussed in detail. Secondary effects related to the thermal characteristics are discussed in simplified models. Preliminary NMR tests of basic solid and liquid samples measured at 600 MHz confirm the central findings of the design study. It is concluded that the stripline structure can be a valuable addition to the NMR toolbox; it combines high sensitivity with low susceptibility broadening and high power handling capabilities in a simple scalable design.
Collapse
|
18
|
A Digital Microfluidic System for the Investigation of Pre-Steady-State Enzyme Kinetics Using Rapid Quenching with MALDI-TOF Mass Spectrometry. Anal Chem 2007; 79:8699-704. [PMID: 17953451 DOI: 10.1021/ac071235x] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
19
|
Abstract
This paper describes the design, modeling, and experimental characterization of an electrochemical sensor array for on-line monitoring of fermentor conditions in both miniaturized cell assays and in industrial scale fermentations. The viable biomass concentration is determined from impedance spectroscopy. As a miniaturized electrode configuration with high cell constant is applied, the spectral conductivity variation is monitored instead of the permittivity variation. The dissolved oxygen concentration is monitored amperometrically using an ultramicroelectrode array, which is shown to have negligible flow dependence. pH is monitored using an ion-sensitive field effect transistor (ISFET), and a platinum thermistor is included for temperature measurements. All sensors were shown to be sufficiently accurate within the range relevant to yeast fermentations. The sensor array is shown to be very stable and durable and withstands steam-sterilization.
Collapse
|
20
|
Directional flow induced by synchronized longitudinal and zeta-potential controlling AC-electrical fields. LAB ON A CHIP 2006; 6:1300-5. [PMID: 17102843 DOI: 10.1039/b607403k] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Electroosmotic flow (EOF) in a microchannel can be controlled by electronic control of the surface charge using an electrode embedded in the wall of the channel. By setting a voltage to the electrode, the zeta-potential at the wall can be changed locally. Thus, the electrode acts as a "gate" for liquid flow, in analogy with a gate in a field-effect transistor. In this paper we will show three aspects of a Field Effect Flow Control (FEFC) structure. We demonstrate the induction of directional flow by the synchronized switching of the gate potential with the channel axial potential. The advantage of this procedure is that potential gas formation by electrolysis at the electrodes that provide the axial electric field is suppressed at sufficiently large switching frequencies, while the direction and magnitude of the EOF can be maintained. Furthermore we will give an analysis of the time constants involved in the charging of the insulator, and thus the switching of the zeta potential, in order to predict the maximum operating frequency. For this purpose an equivalent electrical circuit is presented and analyzed. It is shown that in order to accurately describe the charging dynamics and pH dependency the traditionally used three capacitor model should be expanded with an element describing the buffer capacitance of the silica wall surface.
Collapse
|
21
|
Abstract
The band dispersion in channels with an orderly pillar structure with a pressure-driven liquid flow was determined. Several channels with different geometries were etched in a silicon wafer and enclosed by a glass wafer. The microchannels obtained had the same depth, pillar disposition, and overall porosity, but different pillar diameters and channel widths. The broadening of narrow bands of a fluorescent sample solution flowing through the channels was measured using a fluorescence microscope. It was shown that the peak dispersion occurring in the channels can be much lower than in conventional packed columns, as a consequence of the higher degree of order of the solid structure. Reduced plate heights of approximately 0.2 could be obtained for (nonretained) bands. No correlation was found between the aspect ratio (the ratio of the channel width and the pillar diameter) and band dispersion. The geometrical construction of the sidewall region was shown to play a critical role for channel performance. A good agreement was found with predictions for the optimal sidewall geometry obtained previously with simulation studies.
Collapse
|
22
|
Ultra-rapid separation of an angiotensin mixture in nanochannels using shear-driven chromatography. J Chromatogr A 2006; 1102:96-103. [PMID: 16257004 DOI: 10.1016/j.chroma.2005.10.017] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2005] [Revised: 10/10/2005] [Accepted: 10/11/2005] [Indexed: 11/21/2022]
Abstract
The present paper reports on the separation of a mixture of fluorescein isothiocyanate-labeled angiotensin I and II peptides in a shear-driven nanochannel with a C18-coating and using an eluent consisting of 5% acetonitrile in 0.02 M aqueous phosphate buffer at pH 6.5. The flat-rectangular nanochannel in fused silica consisted of an etched structure in combination with a flat moving wall. The very fast separation kinetics that can be achieved in a nanochannel allowed to separate the angiotensin peptides in less then 0.2 s in a distance of only 1.8 mm. Plate heights as small as 0.4 microm were calculated after substraction of the injection effect.
Collapse
|
23
|
Fabrication and characterization of high-temperature microreactors with thin film heater and sensor patterns in silicon nitride tubes. LAB ON A CHIP 2005; 5:326-336. [PMID: 15726209 DOI: 10.1039/b414857f] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
In this paper the fabrication and electrical characterization of a silicon microreactor for high-temperature catalytic gas phase reactions, like Rh-catalyzed catalytic partial oxidation of methane into synthesis gas, is presented. The microreactor, realized with micromachining technologies, contains silicon nitride tubes that are suspended in a flow channel. These tubes contain metal thin films that heat the gas mixture in the channel and sense its temperature. The metal patterns are defined by using the channel geometry as a shadow mask. Furthermore, a new method to obtain Pt thin films with good adhesive properties, also at elevated temperatures, without adhesion metal is implemented in the fabrication process. Based on different experiments, it is concluded that the electrical behaviour at high temperatures of Pt thin films without adhesion layer is better than that of Pt/Ta films. Furthermore, it is found that the temperature coefficient of resistance (TCR) and the resistivity of the thin films are stable for up to tens of hours when the temperature-range during operation of the microreactor is below the so-called "burn-in" temperature. Experiments showed that the presented suspended-tube microreactors with heaters and temperature sensors of Pt thin films can be operated safely and in a stable way at temperatures up to 700 degrees C for over 20 h. This type of microreactor solves the electrical breakdown problem that was previously reported by us in flat-membrane microreactors that were operated at temperatures above 600 degrees C.
Collapse
|
24
|
Microfabricated Palladium−Silver Alloy Membranes and Their Application in Hydrogen Separation. Ind Eng Chem Res 2004. [DOI: 10.1021/ie034293r] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
25
|
Abstract
We report on the possibility to strongly increase the mass loadability and retention capacity of shear-driven chromatography (SDC) channels by growing a thin porous silicon layer on the stationary wall part. The thickness of the produced porous silicon layers was found to increase linearly with the anodisation time, and could easily be varied between 50 and 300 nm. Combining these layers with sub-microm thin flow-through channels, we believe it is the first time a sub-microm on-chip LC system with a phase ratio similar to that in packed column HPLC (i.e., Vs/Vm approximately equal to 1.5) is obtained. The chromatographic performance of the produced channels has been tested by separating binary mixtures of coumarin dyes under RP-LC conditions. The plate height measurements, yielding Hmin, approximately equal to 0.5 microm (corresponding to more than 2 x 10(6) plates/m) for a retained component with k" = 3, showed good agreement with the theoretical expectations. Due to the presence of some macroscopic defects in the prepared layers, the quality of the separations could however only be maintained over a few millimeters of the channel length. This length was however more than sufficient to separate the coumarin mixture, given the extremely small plate heights of the system.
Collapse
|
26
|
Lab-on-a-chip systems for biomedical and environmental monitoring. Anal Bioanal Chem 2004; 378:1700-3. [PMID: 14758457 DOI: 10.1007/s00216-003-2435-7] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2003] [Revised: 11/18/2003] [Accepted: 11/20/2003] [Indexed: 11/28/2022]
Abstract
During the last decade, pocket-sized analytical equipment based on the "lab-on-a-chip" approach has become available. These chips, in combination with portable electronic equipment, are applicable in, for example, "point-of-care" ion analysis of body fluids, forensics, identification of explosives, tracking of pollution in environmental or waste waters, monitoring nutrients in agricultural or horticultural water, controlling quality in food production, or process control in chemical industry. This paper discusses several demonstrator systems with applications in these fields.
Collapse
|