1
|
Causal effects of body mass index, education, and lifestyle behaviors on intervertebral disc disorders: Mendelian randomization study. J Orthop Res 2024; 42:183-192. [PMID: 37408137 DOI: 10.1002/jor.25656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 05/26/2023] [Accepted: 07/01/2023] [Indexed: 07/07/2023]
Abstract
This study aimed to investigate the causal risk factors for intervertebral disc disorders (IVDD) to help establish prevention strategies for IVDD-related diseases. We performed two-sample Mendelian randomization analyses to investigate the causal effects of body mass index (BMI), education, and lifestyle behaviors (sedentary behavior, smoking, and sleeping) on thoracic/thoracolumbar/lumbosacral IVDD (TTL-IVDD) and cervical IVDD. The inverse-variance weighted (IVW) method was conducted as the primary model to pool effect sizes using odds ratio and 95% confidence interval. The strength of causal evidence was evaluated from the effect size and different Mendelian randomization methods (MR-Egger/weighted median/weighted mode method, Cochran's Q test, leave-one-out analysis, MR Steiger, MR-PRESSO and radial IVW analyses). We found strong evidence for the causal associations between IVDD and BMI (TTL-IVDD, 1.27 [1.18, 1.37], p = 2.40 × 10-10 ; cervical IVDD, 1.24 [1.12, 1.37, p = 6.58 × 10-5 ), educational attainment (TTL-IVDD, 0.57 [0.51, 0.64], p = 9.64 × 10-21 ; cervical IVDD, 0.58 [0.49, 0.68], p = 1.78 × 10-10 ), leisure television watching (TTL-IVDD, 1.54 [1.29, 1.84], p = 7.80 × 10-6 ; cervical IVDD, 1.65 [1.29, 2.11], p = 0.0001), smoking initiation (TTL-IVDD, 1.37 [1.25, 1.50], p = 1.78 × 10-10 ; cervical IVDD, 1.32 [1.16, 1.51], p = 6.49 × 10-5 ), short sleep (TTL-IVDD, 1.28 [1.09, 1.49], p = 0.0027; cervical IVDD, 1.53 [1.21, 1.94], p = 0.0008), or frequent insomnia (TTL-IVDD, 1.20 [1.11, 1.30], p = 1.54 × 10-5 ; cervical IVDD, 1.37 [1.20, 1.57], p = 7.80 × 10-6 ). This study provided genetic evidence that increased BMI, low educational attainment, sedentary behavior by leisure television watching, smoking initiation, short sleep, and frequent insomnia were causal risk factors for IVDD. More efforts should be directed toward increasing public awareness of these modifiable risk factors and mobilizing individuals to adopt healthy lifestyles.
Collapse
|
2
|
Whole-joint histogram analysis of different models of diffusion weighted imaging in evaluating disease activity of axial spondyloarthritis. Br J Radiol 2023; 96:20220420. [PMID: 37751218 PMCID: PMC10646629 DOI: 10.1259/bjr.20220420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 09/06/2023] [Accepted: 09/14/2023] [Indexed: 09/27/2023] Open
Abstract
OBJECTIVES To assess whole-joint histogram analysis of mono-exponential and bi-exponential diffusion weighted and diffusion kurtosis imaging in evaluating disease activity of axial spondyloarthritis (axSpA). METHODS A total of 82 patients with axSpA who underwent both DKI and multi b diffusion weighted imaging of the sacroiliac joints were divided into active and inactive disease groups based on clinical activity indices. Another 17 patients with nonspecific low back pain were included as a control group. The SPARCC scoring system was used to assess the level of sacroiliac joint bone marrow edema. Histogram parameters of apparent diffusion coefficient (ADC), true diffusion coefficient (D), perfusion fraction (f), pseudodiffusion coefficient (D*), mean kurtosis (MK), and mean diffusivity (MD) were calculated. Regions of interest were placed covering the entire sacroiliac joint. Receiver operating characteristic (ROC) analysis was performed to assess the diagnostic performance of imaging parameters in distinguishing different groups. Regression analysis was applied to determine the correlation between imaging parameters and clinical activity indices. RESULTS All of the histogram parameters distinguished the active from inactive groups with a low area under the curve (AUC) (max AUCs≤0.71), while the SPARCC score failed to differentiate the two groups (p = 0.08). MD, MK, D, D*, and ADC showed good performance in differentiating active and inactive from control groups (max AUC = 0. 81 ~ 0.98). f50 differentiated the active from control groups with an AUC of 0.72, significantly lower than the maximum AUC for MD, MK, D, ADC, and SPARCC score (all p < 0.05). The max AUC of MD in differentiating inactive from control groups was significantly higher than that of D* and the SPARCC score. MD, D, D*, f, and ADC were positively correlated with BASDAI, while MK was negatively correlated with BASDAI. Only MD was positively correlated with hsCRP. CONCLUSIONS Whole-joint histogram analysis of mono-exponential, bi-exponential diffusion weighted, and diffusion kurtosis imaging showed good diagnostic performance in differentiating active and inactive axSpA from patients with non-specific back pain. All the imaging parameters were correlated with BASDAI except for SPARCC score. Only DKI-derived MD was correlated with an increase in hsCRP, suggesting its potential use as an imaging biomarker for disease activity in axSpA. ADVANCES IN KNOWLEDGE 1. No significant difference was found between the three models of diffusion weighted imaging in evaluating disease activity of axial spondyloarthritis.2. Only DKI-derived MD was correlated with an increase in hsCRP, suggesting its potential use as an imaging biomarker for disease activity in axSpA.
Collapse
|
3
|
Gastrointestinal tumor-related perihepatic fluorouracil encapsulated lesions and liver metastases: a diagnostic imaging study based on contrast-enhanced computed tomography and magnetic resonance imaging. Quant Imaging Med Surg 2023; 13:7236-7246. [PMID: 37869297 PMCID: PMC10585562 DOI: 10.21037/qims-22-1315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2022] [Accepted: 08/10/2023] [Indexed: 10/24/2023]
Abstract
Background Perihepatic fluorouracil encapsulated lesions (FELs) can result in potentially confusing computed tomography (CT) and magnetic resonance imaging (MRI) features in postoperative examinations of gastrointestinal tumors. This retrospective study aimed to summarize the typical imaging features of FELs and determine the best imaging modality to distinguish FELs from liver metastases for junior residents. Methods Patients with FELs who had undergone gastrointestinal tumor surgery in Tongji Hospital from January 2016 to June 2022 were evaluated. The imaging features of FELs were summarized by two senior radiologists. Contrast-enhanced CT (CECT) was used as the primary follow-up tool for postoperative gastrointestinal tumor patients. Patients with FELs and available CECT and MRI examinations were matched with patients with liver metastases based on gender and age and presented in chronological order in a 2:1 ratio. Different imaging modality combinations were used for further evaluation, including a CECT group (modality Ⅰ), CECT and nonenhanced MRI group (modality Ⅱ) and CECT with all MRI sequences group (modality Ⅲ). Subsequently, two junior residents blindly evaluated three groups following a 4-week interval based on a 5-point scale (1= definite benign lesion, 2= probable benign lesion, 3= indeterminate, 4= probable liver metastasis, 5= definite liver metastasis). Results Imaging features of 33 patients with 36 FELs were analyzed. CECT and dynamic contrast-enhanced MRI (DCE-MRI) showed no enhancement in most lesions. Additionally, 20 patients with FELs meeting the requirements were matched with 40 patients with liver metastases. The highest sensitivity, specificity, and consistency for identifying liver metastases were achieved using a combination of CECT and MRI encompassing all sequences yielded, including modality Ⅰ (reader 1: 72.0% and 17.4%; reader 2: 62.0% and 17.4%; kappa value 0.295), modality Ⅱ (reader 1: 88.0% and 8.7%; reader 2: 92.0% and 34.8%; kappa value 0.259), and modality Ⅲ (reader 1: 98.0% and 34.8%; reader 2: 92.0% and 39.1%; kappa value 0.680). Conclusions FELs are typically non-enhancing lesions. In our study, two junior residents could best distinguish FELs from liver metastases using CECT with all MRI sequences.
Collapse
|
4
|
Differentiation of giant cell tumors of bone, primary aneurysmal bone cysts, and aneurysmal bone cysts secondary to giant cell tumor of bone: Using whole-tumor CT texture analysis parameters as quantitative biomarkers. Clin Radiol 2023:S0009-9260(23)00096-X. [PMID: 37117049 DOI: 10.1016/j.crad.2023.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 02/15/2023] [Accepted: 03/06/2023] [Indexed: 03/30/2023]
Abstract
AIM To determine whether computed tomography (CT) texture analysis parameters can be used as quantitative biomarkers to help differentiate giant cell tumour of bones (GCTs), primary aneurysmal bone cysts (PABCs), and aneurysmal bone cysts (ABCs) secondary to giant cell tumours of bone (GABCs). MATERIALS AND METHODS One hundred and seven patients with 63 GCTs, 31 PABCs, and 13 GABCs were analysed retrospectively. All patients underwent preoperative CT. Two radiologists independently evaluated the qualitative features of the CT images and extracted texture parameters. Patient demographics, qualitative features, and texture parameters among GCTs, PABCs, and GABCs were compared statistically. Differences in these parameters between ABCs and GCTs were also assessed. ROC curves were obtained to determine optimal parameter values. RESULTS The best preoperative CT parameters to differentiate GCTs, PABCs, and GABCs included one qualitative feature (location around the knee) and four texture parameters (95th percentile, maximum intensity, skewness, and kurtosis). Age and three texture parameters (5th percentile, inhomogeneity, and kurtosis) enabled statistically significant differentiation between GCTs and ABCs. Combination of the above four parameters generated the largest area under the ROC curve (AUC) for the differentiation of GCTs and ABCs. CONCLUSION CT texture analysis parameters can be used as quantitative biomarkers for preoperative differentiation among GCTs, PABCs, and GABCs.
Collapse
|
5
|
Diurnal Variation in Hydration of the Cervical Intervertebral Disc Assessed Using T2 Mapping of Magnetic Resonance Imaging. Korean J Radiol 2022; 23:638-648. [PMID: 35617994 PMCID: PMC9174496 DOI: 10.3348/kjr.2021.0950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 03/10/2022] [Accepted: 04/01/2022] [Indexed: 11/15/2022] Open
Abstract
Objective The study aimed to investigate the diurnal variation in cervical disc hydration and its relationship with cervical degeneration. Materials and Methods C3–C7 discs of 86 prospectively enrolled participants (37 males, 49 females; mean age ± standard deviation, 23.5 ± 2.5 years) were assessed using T2 mapping in the morning and evening. All discs were stratified by Miyazaki grade or C2–C7 Cobb angle and T2 values (T2). The degree of diurnal T2 variation (T2-DDV), defined as (morning T2 – evening T2)/morning T2 × 100%, was measured for the entire disc, annulus fibrosus (AF), nucleus pulposus (NP), and endplate zones. Results T2 of the entire disc decreased significantly after the daytime load (p < 0.001), with a T2-DDV of 13.3% for all discs and 16.0%, 12.2%, and 13.0% for healthy (grade I), mild degenerative (grade II), and advanced degenerative (grade III/IV) discs, respectively. T2 of regional NPs and AFs decreased significantly from morning to evening (p ≤ 0.049) except in the healthy anterior inner AF (p = 0.092). Compared with healthy discs, mild degenerative discs displayed lower T2 and T2-DDV in regional NPs (p < 0.001). Advanced degenerative discs showed higher T2-DDV in the anterior inner AF compared with healthy discs (p = 0.050). Significant diurnal T2 changes in the endplate zones were observed only in healthy discs (p = 0.013). Cervical discs in the low Cobb angle group showed higher T2-DDV in the anterior AFs and anterior NP and lower T2-DDV in the posterior AF than those in the high Cobb angle group (p ≤ 0.041). Conclusion This study characterized the diurnal variation in hydration of the cervical discs as assessed using T2 mapping and revealed early chemo-mechanical coupling dysfunction in degenerating discs. Cervical sagittal alignment on MRI can affect the diurnal stress patterns of the cervical discs. T2 mapping is sensitive to disc biomechanical dysfunction and offers translational potential from biomechanical research to clinical application.
Collapse
|
6
|
Incidence of pulmonary embolism and impact on mortality in patients with malignant melanoma. Clin Imaging 2021; 83:72-76. [PMID: 34990983 DOI: 10.1016/j.clinimag.2021.12.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 12/02/2021] [Accepted: 12/21/2021] [Indexed: 11/18/2022]
Abstract
PURPOSE Pulmonary embolism (PE) occurs frequently in patients with malignant melanoma (MM). The aim of this study is to determine the incidence of PE in patients with MM and to assess the clinical characteristics and mortality of MM patients with PE. MATERIAL AND METHODS Medical records from 381 MM patients who underwent contrast-enhanced computed tomography were evaluated. Imaging parameters including location of PE and measurements of right heart dysfunction and clinical parameters including D-Dimer levels, local and distant tumor stage and time of death were analyzed. RESULTS PE was found in 23/381 (6%) MM patients, whereby 17/23 (74%) were detected incidentally and only 6/23 (26%) were symptomatic. The presence of PE significantly correlated with elevated D-Dimers (p < 0.001), right ventricular dysfunction (p = 0.04), higher local tumor stage (≥T3) (p = 0.05), presence of visceral (p = 0.02) or cerebral metastases (p = 0.03) and increased mortality (p = 0.05). Further, patients with central PE showed an increased mortality compared to peripheral PE (p = 0.03), but no correlation was found between the localization of PE and the occurrence of clinical symptoms (p = 0.36). CONCLUSION PE in patients with MM often occurs without clinical symptoms and is indicative for advanced disease and a poorer prognosis.
Collapse
|
7
|
Cross-reactivity among iodinated contrast agents: should we be concerned? Quant Imaging Med Surg 2021; 11:4028-4041. [PMID: 34476187 DOI: 10.21037/qims-20-1325] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 04/14/2021] [Indexed: 11/06/2022]
Abstract
Background Although several papers deal with "cross-reactivity" in patients with iodinated contrast medium (ICM) hypersensitivity reactions (HSRs), there is no in-depth knowledge of this phenomenon. To define ICM-groups as potential reaction partners and to identify any potential clinical relevance in patients with ICM-HSRs. Methods The literature database PubMed was searched for eligible papers dealing with ICM-allergy and "cross-reactivity". The data presented by the papers was analyzed and individual patient data was extracted for re-evaluation based on a definition for both 'polyvalent reactivity' and 'cross-reactivity' as well as for chemical structure-dependent ICM-groups. Results Twenty-five original papers (with n=340 extracted patients) formed the study population. Incidences of polyvalent reactivity were non-significantly higher than incidences of cross-reactivity (both range from 0% to 100%). Crossover evaluation in reaction pairings (culprit ICM A with ICM B versus culprit ICM B with ICM A) showed concordance of only 30%. Data support rather non-cross-reactivity (individual reaction pattern) than cross-reactivity constellations. Conclusions The obtained results favour an individual reaction pattern, rather than a reactivity driven by chemical structures and so-called cross-reactivity.
Collapse
|
8
|
Differentiation of hepatocellular carcinoma from intrahepatic cholangiocarcinoma and combined hepatocellular-cholangiocarcinoma in high-risk patients matched to MR field strength: diagnostic performance of LI-RADS version 2018. Abdom Radiol (NY) 2021; 46:3168-3178. [PMID: 33660040 DOI: 10.1007/s00261-021-02996-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Revised: 02/07/2021] [Accepted: 02/11/2021] [Indexed: 02/07/2023]
Abstract
PURPOSE To eliminate the effects of field strength in determining the diagnostic performance of the LI-RADS version 2018 (LI-RADS v2018) in differentiating hepatocellular carcinoma (HCC) from non-HCC primary liver malignancy in high-risk patients. METHODS Patients who were pathologically confirmed intrahepatic cholangiocarcinoma (iCCA) or combined hepatocellular-cholangiocarcinoma (cHCC-CCA) were retrospectively reviewed. Patients with HCC were matched to the iCCA or cHCC-CCA patients on age, tumor size, MR scanner, and number of tumors. Two readers independently evaluated the lesions according to LI-RADS v2018. Diagnostic performance of LI-RADS v2018 in differentiating HCC from non-HCC primary liver malignancy were analyzed. RESULTS A total of 198 patients with 204 lesions (102 HCCs, 78 iCCAs, and 24 cHCC-CCAs) were enrolled. The sensitivity and specificity of LR-5 or LR-TIV (definitely due to HCC) in diagnosing HCC were 68.63% and 85.29%, respectively. LR-M or LR-TIV (may be due to non-HCC malignancy) had a sensitivity of 72.55% and a specificity of 86.27% in diagnosing non-HCC malignancy. The sensitivity of LR-M or LR-TIV (may be due to non-HCC malignancy) for iCCA and cHCC-CCA was 82.05% and 41.67%, respectively. Nearly half (11/24, 45.83%) of cHCC-CCAs were categorized as LR-5. Three tesla MR showed higher sensitivity than 1.5 T in diagnosing HCC (80.00% vs 57.69%, P = 0.015). CONCLUSION When the effect of field strength was eliminated, LI-RADS v2018 demonstrated high specificity but suboptimal sensitivity in distinguishing HCC from non-HCC primary liver carcinomas. Most iCCAs were categorized as LR-M or LR-TIV (may be due to non-HCC malignancy). However, nearly half of cHCC-CCAs were assigned as LR-5.
Collapse
|
9
|
The Diagnostic Value of MR IVIM and T2 Mapping in Differentiating Autoimmune Myositis From Muscular Dystrophy. Acad Radiol 2021; 28:e182-e188. [PMID: 32417032 DOI: 10.1016/j.acra.2020.04.022] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Revised: 04/11/2020] [Accepted: 04/12/2020] [Indexed: 01/15/2023]
Abstract
RATIONALE AND OBJECTIVES To confirm the feasibility and compare the accuracy of magnetic resonance imaging intravoxel incoherent motion (IVIM) and T2 mapping models for the differentiation of autoimmune myositis from muscular dystrophy. MATERIALS AND METHODS Fourty-two autoimmune myositis and 11 muscular dystrophy patients proven by diagnostic criteria were enrolled in the study. Conventional MR sequences, IVIM, and T2 mapping through the bilateral thighs were obtained as well as blood samples for all patients. IVIM and T2 mapping parameters as well as serum markers were compared between the autoimmune myositis and muscular dystrophy groups. Mann-Whitney U tests were performed for statistical analysis along with receiver operating characteristic curves. Spearman correlation coefficient models were constructed to analyze the correlation between IVIM and T2 mapping with serological parameters. RESULTS The intramuscular apparent diffusion coefficient, tissue diffusivity (D), perfusion fraction (fp), and T2 relaxation time values were statistically significantly different between the autoimmune myositis and muscular dystrophy groups (p < 0.05). Pseudo diffusivity (Dp) values showed no statistical difference between the groups (p > 0.05). D parameter of IVIM sequences differentiated autoimmune and muscular dystrophy with a higher specificity of 75.60%. T2 values within the thighs were correlated with serum creatine kinase and lactate dehydrogenase levels (p < 0.05). CONCLUSION Thigh muscle IVIM and T2 mapping parameters are useful in differentiating autoimmune myositis from muscular dystrophy, particularly the IVIM parameters.
Collapse
|
10
|
Utility of noncontrast MRI in the detection and risk grading of gastrointestinal stromal tumor: a comparison with contrast-enhanced CT. Quant Imaging Med Surg 2021; 11:2453-2464. [PMID: 34079715 DOI: 10.21037/qims-20-578] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Background Recently developed adjuvant therapies for gastrointestinal stromal tumor (GIST) have been shown to improve patient survival. Guidelines currently recommend contrast-enhanced computed tomography (CECT) for GIST detection and surveillance. Patients with moderate-to-high risk GISTs require more frequent surveillance due to a higher 5-year recurrence rate. Our study aimed to compare noncontrast magnetic resonance imaging (MRI) with CECT for GIST detection, and evaluate volumetric apparent diffusion coefficients (ADCs) for risk stratification of GIST. Methods We retrospectively enrolled 83 patients with histopathologically confirmed GISTs for lesion detection efficiency analysis between noncontrast MRI and matched CECT studies. A 5-point scale was used by two independent reviewers to determine if the lesion was present or absent. Another cohort, comprising 28 patients with pathologically confirmed primary GISTs, was further screened for risk stratification, with a comparison of volumetric ADC parameters between the pathologically very-low-to-low risk and moderate-to-high risk GIST patients. Results For identifying GISTs, the sensitivity and specificity of noncontrast MRI were 83.6% and 89.3% for reader 1 respectively, and 81.8% and 92.9% for reader 2 respectively; the sensitivity and specificity of CECT were 76.4% and 89.3% for reader 1 respectively, and 76.4 and 78.6% for reader 2 respectively. Tumor volumetric ADC histogram parameters, including ADCmax, ADCstdev, 90th and 95th percentiles, inhomogeneity, and entropy, were positively correlated with a higher risk grade of GIST (r=0.421-0.758). The receiver operator characteristic curve analysis showed ADCmax achieved the highest area under the curve value of 0.938 for discriminating very-low-to-low risk versus moderate-to-high risk GISTs. Conclusions Noncontrast MRI was an efficient technique for identifying GIST patients. The combination of CECT and noncontrast MRI can improve the reliability of diagnosis. For patients with contraindications to CECT, noncontrast MRI may be a comparable alternative. Volumetric ADC histogram parameters may be useful in differentiating very-low-to-low risk from moderate-to-high risk primary GISTs.
Collapse
|
11
|
CT facilitates improved diagnosis of adult intestinal malrotation: a 7-year retrospective study based on 332 cases. Insights Imaging 2021; 12:58. [PMID: 33929625 PMCID: PMC8087751 DOI: 10.1186/s13244-021-00999-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 04/21/2021] [Indexed: 12/17/2022] Open
Abstract
Objective To classify adult intestinal malrotation by CT. Methods This retrospective study enrolled adults diagnosed with intestinal malrotation who underwent abdominal CT at our institution between June 1, 2013, and August 30, 2020. All patients’ clinical information was recorded. Patients were divided into groups undergoing surgical and conservative management. The duodenum (nonrotation, partial rotation, and malrotation), jejunum, cecum, and the superior mesenteric artery/superior mesenteric vein relationship were reviewed on the CT images of each patient, and classification criteria developed based on the first three items. For each patient, each item was assessed separately by three radiologists. Consensus was required from at least two of them. Results A total of 332 eligible patients (218 men and 114 women; mean age 51.0 ± 15.3 years) were ultimately included and classified into ten types of malrotation. Duodenal partial rotation was present in most (73.2%, 243/332) with only 25% (83/332) demonstrating nonrotation. The jejunum was located in the right abdomen in 98.2% (326/332) of cases, and an ectopic cecum was found in only 12% (40/332, 29 cases with a left cecum, 7 pelvic, and 4 at midline). Asymptomatic patients comprised 56.6% (188/332) of cases, much higher than that in previous studies (17%, n = 82, p < .001), comprised mainly of patients with duodenal partial rotation (80.3%, 151/188). In 91 patients with detailed clinical data available (12 managed surgically and 79 conservatively), a significant difference in malrotation CT categorization was identified (p = .016). Conclusions CT enables greater detection of asymptomatic intestinal malrotation, enabling classification into multiple potentially clinically relevant subtypes. Supplementary Information The online version contains supplementary material available at 10.1186/s13244-021-00999-3.
Collapse
|
12
|
Association Between MRI-Based Tibial Slope Measurements and Mucoid Degeneration of the Anterior Cruciate Ligament: A Propensity Score-Matched Case-Control Study. Orthop J Sports Med 2020; 8:2325967120962804. [PMID: 33225010 PMCID: PMC7658517 DOI: 10.1177/2325967120962804] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Accepted: 05/22/2020] [Indexed: 12/16/2022] Open
Abstract
Background The cause of mucoid degeneration (MD) of the anterior cruciate ligament (ACL), which is commonly observed on magnetic resonance imaging (MRI) of patients with knee pain, has yet to be elucidated. Despite the limited evidence on the relationship between ACL lesions (injury and MD) and tibial morphologic features (ie, posterior tibial slope), the potential association between the presence of ACL MD and medial and lateral tibial slope (MTS and LTS) has not been well-established. Purpose To investigate whether MTS and LTS measurements are associated with the presence of ACL MD. Study Design Cross-sectional study; Level of evidence, 3. Methods Consecutive knee MRI examinations of patients referred by an orthopaedic surgeon for potential internal joint derangements were identified within a 4-year period. The presence of ACL MD and the MTS/LTS values were assessed by independent expert observers in consensus in a blinded fashion. From 413 consecutive knee MRI scans, a sample of 80 knees, including 32 knees with ACL MD (cases) and 48 knees with normal ACL (controls), were selected using propensity score matching method for age, sex, body mass index, and presence of severe medial tibiofemoral compartment cartilage damage. The association between ACL MD and MTS/LTS was evaluated using conditional regression models. Results Knees with ACL MD had higher values of LTS (mean ± SD, 7.18° ± 3.58°) in comparison with control knees (5.32° ± 3.35°). Conditional regression analysis revealed a significant association between LTS measurements (not MTS) and ACL MD; every 1° increase in LTS was associated with a 17% (95% CI, 1%-35%) higher probability of having ACL MD. Conclusion Excessive LTS was associated with the presence of ACL MD, independent of participants' age, sex, BMI, and cartilage damage severity.
Collapse
|
13
|
Abstract
To investigate the feasibility of histogram analysis with computed tomography angiography (CTA) in distinguishing between soft tissue sarcomas and benign soft tissue tumors. Fourty nine patients (23 men, mean age = 44.3 years, age range = 25-64) with pathologically-confirmed soft tissue sarcoma (n = 24) or benign soft tissue tumors (n = 25) in the lower extremities undergoing CTA for tumor evaluation were retrospectively analyzed. Two radiologists separately performed histogram analyses of CT density with CTA images by drawing a region of interest (ROI). The 10th (P10), 25th (P25), 50th (P50), 75th (P75), 90th percentiles (P90), mean, and standard deviations (SD) of measured tumor density were obtained along with measurements of the absolute value of kurtosis (AVK), absolute value of skewness (AVS), and inhomogeneity for each tumor. Intra-class correlation coefficients (ICC) were calculated to determine inter- and intra-reader variability in parameter measurements. The Mann-Whitney U test was used to compare histogram parameters between soft tissue sarcomas and benign soft tissue tumors. Receiver operator characteristic (ROC) curves were constructed to evaluate the accuracy of tumor discrimination. ICC was greater than 0.7 for AVS, AVK, and inhomogeneity, and >0.9 for mean, SD, and all percentile measures. There was no significant difference in P10, P25, P50, P75, P90, mean, or SD between soft tissue sarcomas and benign tumors (P > .05). AVS, AVK, and inhomogeneity were significantly higher in soft tissue sarcomas (P < .05). Areas under the curve (AUC) were 0.81, 0.83, and 0.84 for AVS, AVK, and inhomogeneity respectively. AUC were below 0.6 for mean, SD, and all percentiles.Skewness, kurtosis, and inhomogeneity measurements derived from histogram analysis from CTA distinguish between soft tissue sarcomas and benign soft tissue tumors.
Collapse
|
14
|
A Systematic Review of Technical Parameters for MR of the Small Bowel in non-IBD Conditions over the Last Ten Years. Sci Rep 2019; 9:14100. [PMID: 31575890 PMCID: PMC6773732 DOI: 10.1038/s41598-019-50501-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Accepted: 09/13/2019] [Indexed: 12/27/2022] Open
Abstract
Technical guidelines for magnetic resonance imaging (MRI) of the small bowel (SB) in the setting of inflammatory bowel diseases (IBDs) were detailed in a 2017 consensus issued by European Society of Gastrointestinal and Abdominal Radiology (ESGAR) and European Society of Pediatric Radiology (ESPR); however, MRI for non-IBD conditions was not addressed. Hence, we performed a systematic review collecting researches on SB MRI for non-IBDs. The literatures were then divided into morphologic group and functional group. Information about the MRI techniques, gastrointestinal preparation, and details of cine-MRI protocols was extracted. We found that a 1.5 T MRI system, prone positioning, and MR enterography were frequently utilized in clinical practice. Gadolinium contrast sequences were routinely implemented, while diffusion-weighted imaging (DWI) was much less performed. The gastrointestinal preparation varied throughout the studies. No uniform protocols for cine imaging could be established. SB MRI examinations for non-IBDs are far from standardized, especially for functional studies. Recommendations for standard parameters in cine-MRI sequences are difficult to make due to lack of evidentiary support. MRI investigations in non-IBD conditions are needed and the standardization of non-IBD imaging in clinical practice is required.
Collapse
|
15
|
Quantitative diffusion-weighted magnetic resonance enterography in ileal Crohn's disease: A systematic analysis of intra and interobserver reproducibility. World J Gastroenterol 2019; 25:3619-3633. [PMID: 31367161 PMCID: PMC6658399 DOI: 10.3748/wjg.v25.i27.3619] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Revised: 05/20/2019] [Accepted: 06/08/2019] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Magnetic resonance enterography (MRE) is increasingly attractive as a noninvasive and radiation-free tool for assessing Crohn’s disease (CD). Diffusion-weighted imaging (DWI) is recommended as an optional MRE sequence for CD by the European Society of Gastrointestinal and Abdominal Radiology, and has shown a superb potential as a quantitative modality for bowel inflammation evaluation. However, the measurement reproducibility of quantitative DWI analysis in MRE has not been ascertained so far. To facilitate the application of quantitative diffusion-weighted MRE in the clinical routine, systematic investigations of the intra and interobserver reproducibility of DWI quantitative parameters should be performed.
AIM To evaluate the intra and interobserver reproducibility of quantitative analysis for diffusion-weighted MRE (DW-MRE) in ileal CD.
METHODS Forty-four subjects (21 with CD and 23 control subjects) who underwent ileocolonoscopy and DW-MRE (b = 800 s/mm2) within one week were included. Two radiologists independently measured apparent diffusion coefficients (ADC) of the terminal ileum and signal intensity ratio (SR) of the terminal ileum to ipsilateral psoas muscle on DWI images (b = 800 s/mm2). Between- and within-reader agreements were assessed using intraclass correlation coefficients (ICC), coefficients of variation (CoV), and 95% limits of agreement of Bland-Altman plots (BA-LA LoA). Diagnostic performances of ADC and SR for identifying inflamed terminal ileum from the normal were evaluated by receiver operating characteristic (ROC) curve analysis.
RESULTS There were no significant differences in ADC or SR values between the two sessions or between the two radiologists either in the CD or control group (paired t-test, P > 0.05). The intra and interobserver reproducibility of ADC (ICC: 0.952-0.984; CoV: 3.73-6.28%; BA-LA LoA: ±11.27% to ±15.88%) and SR (ICC: 0.969-0.989; CoV: 3.51%-4.64%; BA-LA LoA: ±10.62% to ±15.45%) was excellent for CD. Agreement of ADC measurements was slightly less in control subjects (ICC: 0.641-0.736; CoV: 10.47%-11.43%; BA-LA LoA: ± 26.59% to ± 30.83%). SR of normal terminal ileum demonstrated high intra and interobserver reproducibility (ICC: 0.944-0.974; CoV: 3.73%-6.28%; BA-LA LoA: ± 18.58% to ± 24.43%). ADC and SR of two readers had outstanding diagnostic efficiencies (area under the ROC curve: 0.923-0.988).
CONCLUSION Quantitative parameters derived from DW-MRE have good to excellent intra and interobserver agreements with high diagnostic accuracy, and can serve as robust and efficient quantitative biomarkers for CD evaluation.
Collapse
|
16
|
Repeatability and reproducibility of cerebral 23Na imaging in healthy subjects. BMC Med Imaging 2019; 19:26. [PMID: 30943911 PMCID: PMC6446283 DOI: 10.1186/s12880-019-0324-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Accepted: 03/11/2019] [Indexed: 02/04/2023] Open
Abstract
Background Initial reports of 23Na magnetic resonance imaging (MRI) date back to the 1970s. However, methodological challenges of the technique hampered its widespread adoption for many years. Recent technical developments have overcome some of these limitations and have led to more optimal conditions for 23Na-MR imaging. In order to serve as a reliable tool for the assessment of clinical stroke or brain tumor patients, we investigated the repeatability and reproducibility of cerebral sodium (23Na) imaging in healthy subjects. Methods In this prospective, IRB approved study 12 consecutive healthy volunteers (8 female, age 31 ± 8.3) underwent three cerebral 23Na-MRI examinations at 3.0 T (TimTrio, Siemens Healthineers) distributed between two separate visits with an 8 day interval. For each scan a T1w MP-RAGE sequence for anatomical referencing and a 3D-density-adapted, radial GRE-sequence for 23Na-imaging were acquired using a dual-tuned (23Na/1H) head-coil. On 1 day, these scans were repeated consecutively; on the other day, the scans were performed once. 23Na-sequences were reconstructed according to the MP-RAGE sequence, allowing direct cross-referencing of ROIs. Circular ROIs were placed in predetermined anatomic regions: gray and white matter (GM, WM), head of the caudate nucleus (HCN), pons, and cerebellum. External 23Na-reference phantoms were used to calculate the tissue sodium content. Results Excellent correlation was found between repeated measurements on the same day (r2 = 0.94), as well as on a different day (r2 = 0.86). No significant differences were found based on laterality other than in the HCN (63.1 vs. 58.7 mmol/kg WW on the right (p = 0.01)). Pronounced inter-individual differences were identified in all anatomic regions. Moderate to good correlation (0.310 to 0.701) was found between the readers. Conclusion Our study has shown that intra-individual 23Na-concentrations in healthy subjects do not significantly differ after repeated scans on the same day and a pre-set time interval. This confirms the repeatability and reproducibility of cerebral 23Na-imaging. However, with manual ROI placement in predetermined anatomic landmarks, fluctuations in 23Na-concentrations can be observed.
Collapse
|
17
|
Abstract
OBJECTIVE: To explore and confirm feasibility the T2 maps and readout-segmented echoplanar imaging (rs-EPI) diffusion-weighted imaging (DWI) characteristics of the thigh muscles for dermatomyositis (DM) patients. METHODS: This study was approved by the University Institutional Review and written informed consent was obtained from all subjects before enrollment (trial registration number: TJ-C20121221). 28 patients with DM proven by diagnostic criteria were enrolled in the study along with 9 healthy control subjects. Conventional MR, T2 maps and rs-EPI DWI were obtained for all subjects. Both of T2 and apparent diffusion coefficient (ADC) values for thigh muscles were compared between the DM and healthy control groups. The amount of inflammation and fatty infiltration were respectively assigned a score of 0 to 5 for all thigh muscles. The Kruskal-Wallis tests were utilized and the Spearman correlation coefficients models were used to correlate both of the T2 and ADC value with non-quantitative MRI. P-values <0.05 reflected statistical significance. RESULTS: Both of the T2 and ADC values among all affected muscles, unaffected muscles and the control groups were respectively statistical difference (p < 0.05 respectively), the T2 value of affected muscles was greater than that of unaffected muscles in DM patients (p < 0.05). Differences of the T2 value in DM patients among the combination the edematous with fatty infiltration score groups were statistically significant (p < 0.001). The T2 value showed a significant correlation with the non-quantitative MRI score for edema and fatty infiltration. CONCLUSIONS: T2 maps may have a specialized ability for the detection severity of damaged muscles in comparison to the rs-EPI DWI sequence. ADVANCES IN KNOWLEDGE: A new application of rs-EPI DWI is proposed for DM patients. First, comparison of T2 maps and rs-EPI DWI technology are applied for DM. The results demonstrate that T2 maps may be more potential value in determining the severity of diseased muscles for DM patients.
Collapse
|
18
|
Accelerated MRI of the Lumbar Spine Using Compressed Sensing: Quality and Efficiency. J Magn Reson Imaging 2018; 49:e164-e175. [PMID: 30267462 DOI: 10.1002/jmri.26526] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2018] [Revised: 09/10/2018] [Accepted: 09/12/2018] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND Decreasing MRI scan time is a key factor to increase patient comfort and compliance as well as the productivity of MRI scanners. PURPOSE/HYPOTHESIS Compressed sensing (CS) should significantly accelerate 3D scans. This study evaluated the clinical application and cost effectiveness of accelerated 3D T2 sequences of the lumbar spine. STUDY TYPE Prospective, cross-sectional, observational. POPULATION Twenty healthy volunteers and 10 patients. FIELD STRENGTH/SEQUENCE A 3D T2 TSE sequence, identical 3D sequences with three different parallel imaging and CS accelerating factors, and 2D TSE sequences as a clinical reference were obtained on a 3T scanner. ASSESSMENT Three readers evaluated the sequences for delineation of anatomical structures and image quality. A quantitative analysis consisting of root mean square error, structural similarity index, signal-to-noise ratio, and contrast-to-noise ratio were performed. The scan times were used to calculate cost differences for each sequence. STATISTICAL TESTS An analysis of variance with repeated measurements and the Friedman test were used to test for potential differences between the sequences. Post-hoc analysis was made with the chi-squared and Tukey-Kramer test. RESULTS CS with factor 4.5 results in unchanged image quality compared to the T2 TSE for volunteers and patients (overall image impression: 4.75 vs. 4.20 [P = 0.73] and 4.90 vs. 4.47 [P = 0.44]). The CS 4.5 scan is 167 seconds (-39%) faster than the 3D and 216.5 seconds (-45%) faster than the 2D sequences. No significant differences was found for the diagnostic certainty in the volunteers and patients between 2D TSE and 3D CS 4.5 (P = 0.89 and P = 0.43). A reduction of scan time to 148 seconds (CS 8) was still rated acceptable for most diagnosis. DATA CONCLUSION CS accelerates the 3D T2 without compromising image quality. The 3D sequences offer comparable diagnostic quality to the clinical 2D standard with less scan time (-45%), potentially increasing the productivity of MRI scanners. LEVEL OF EVIDENCE 1 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2019;49:e164-e175.
Collapse
|
19
|
T2 mapping in dermatomyositis/polymyositis and correlation with clinical parameters. Clin Radiol 2018; 73:1057.e13-1057.e18. [PMID: 30172348 DOI: 10.1016/j.crad.2018.07.106] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Accepted: 07/24/2018] [Indexed: 12/24/2022]
Abstract
AIM To explore the T2-mapping signal characteristics of the thigh muscles in patients with dermatomyositis/polymyositis (DM/PM) and to investigate the correlation between thigh muscle T2 values, clinical parameters, and serum creatinine kinase (CK). MATERIALS AND METHODS Forty-two patients with DM/PM proven by diagnostic criteria were enrolled in the study along with 13 healthy control subjects. Both T2-mapping and conventional magnetic resonance imaging (MRI) images were obtained in the thigh musculature of all subjects. The T2 values of thigh muscles were compared between the DM/PM patients and control groups. Thirty-one DM/PM patients were evaluated with manual muscle testing (MMT) and serum CK levels. A Spearman correlation coefficient model was used to correlate the mean T2 values and clinical assessments. The Kruskal-Wallis test and receiver operating characteristic (ROC) curves were also utilised. p-Values <0.05 reflected statistical significance. RESULTS The T2 value of all oedematous muscles was greater on average than that of the unaffected muscles of the DM/PM patients (p<0.05) and the muscles of healthy volunteers (p<0.05). The T2 value of unaffected muscles in DM/PM patients was also greater than that of the normal muscles in healthy volunteers (p<0.05). The area under the curves (AUCs) for T2 relaxation time values was 0.72 with respective sensitivity and specificity of 72.6% and 65.4%. The mean T2 relaxation time of the 31 patients group and the MMTs (p<0.05) was correlated without serum CK levels (p>0.05). CONCLUSION T2 mapping is not only quantitatively used for subclinical muscle involvement in DM/PM, but also be used to demonstrate severity of damaged muscles in DM/PM.
Collapse
|
20
|
Can computed tomography volumetry of the renal cortex replace MAG3-scintigraphy in all patients for determining split renal function? Eur J Radiol 2018; 103:105-111. [DOI: 10.1016/j.ejrad.2018.04.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2018] [Revised: 04/06/2018] [Accepted: 04/16/2018] [Indexed: 11/16/2022]
|
21
|
Abstract
Magnetic resonance imaging (MRI) is the modality of choice for liver imaging due to its superior contrast resolution in comparison with computer tomography and the ability to provide both morphologic and physiologic information. The physics of MR are complex, and a detailed understanding is not required to appreciate findings on an MRI exam. Here, we attempt to introduce the basic principles of MRI with respect to hepatic imaging focusing on various commonly encountered hepatic diseases. The purpose is to facilitate an appreciation of the various diagnostic capabilities of MR among hepatic oncologists and surgeons and to foster an understanding of when MR studies may be appropriate in the care of their patients.
Collapse
|
22
|
Combined Static and Dynamic Computed Tomography Angiography of Peripheral Artery Occlusive Disease: Comparison with Magnetic Resonance Angiography. Cardiovasc Intervent Radiol 2018; 41:1205-1213. [PMID: 29484465 DOI: 10.1007/s00270-018-1911-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Accepted: 02/17/2018] [Indexed: 10/17/2022]
Abstract
PURPOSE To compare in patients with known peripheral artery occlusive disease (PAOD), image quality of a combined CTA to a combined MRA protocol, including both static and dynamic acquisitions. MATERIALS AND METHODS Twenty-two patients with PAOD were examined with a combined CTA and MRA protocol consisting of static acquisitions (s-CTA, s-MRA) of the entire runoff and dynamic acquisitions (d-CTA, d-MRA) of the calves. Two radiologists compared image quality of the s-MRA versus s-CTA as well as d-MRA versus d-CTA. Image quality was assessed on a segmental basis using a 4-point Likert scale. RESULTS For s-CTA, 76% of segments were rated as excellent or good. For s-MRA, 50% of segments were rated as excellent or good (p < 0.0001). For d-CTA, median image quality score for all segments was rated as excellent for both readers. For d-MRA, median image quality for the different segments ranged from moderate to good. For both d-CTA and d-MRA, the median image quality scores were significantly higher for all segments of the lower limb compared with the static examinations of the lower limb segments (all p values < 0.0001). In patients with PAOD category 4-6, 80% of segments were rated as excellent or good for d-CTA, while 45% of segments were rated as poor or non-diagnostic for d-MRA. CONCLUSION In patients with known PAOD, a combined static and dynamic CTA examination improves image quality relative to static and dynamic MRA and should be considered as an alternative to MRA, particularly in patients with advanced stage PAOD.
Collapse
|
23
|
Is There a Role for Functional MRI for the Assessment of Extracapsular Extension in Prostate Cancer? Anticancer Res 2018; 38:427-432. [PMID: 29277805 DOI: 10.21873/anticanres.12240] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2017] [Revised: 11/06/2017] [Accepted: 11/08/2017] [Indexed: 11/10/2022]
Abstract
BACKGROUND/AIM Exctracapsular extension (ECE) in prostate cancer has a high impact on treatment decision. MRI might predict presence of ECE non-invasively. PATIENTS AND METHODS Triplanar T2w-sequences, DWI (diffusion weighted imaging) and DCE (dynamic contrast-enhanced imaging) of 34 patients with PCa were analyzed to prior prostatectomy. Sensitivity (SS) and specificity (SP) of T2w, apparent diffusion coefficient (ADC), plasma flow (PF) and mean transit time (MTT) normalized by PCa/normal tissue ratio for prediction of CI (capsular infiltration)/ECE were determined by area-under-the-receiver-operating-characteristics analysis. RESULTS SS/SP for detecting ECE was 29/85. AUC (area under the curve) of ECE cases was 0.98/0.92/0.69 (cut-off-ratios 3.2/0.51/0.46), SS 93/100/86% and SP 95/80/50% for PF-/MTT-/ADC-ratios, respectively. PF- and MTT-ratios between CI and without CI/ECE differed significantly (PF, p<0.0001; MTT, p=0.0134) with SS/SP 84/89% for PF and SS/SP 52/100% for MTT-ratios. No significant differences regarding ADC-ratios were identified. CONCLUSION ECE/CI can be assessed by quantitative DCE analysis with great diagnostic confidence and higher specificity than ADC.
Collapse
|
24
|
Role for imaging in spondyloarthritis. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF RADIOPHARMACEUTICAL CHEMISTRY AND BIOLOGY 2017; 61:271-282. [PMID: 28497939 DOI: 10.23736/s1824-4785.17.02981-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
INTRODUCTION Despite major progress in the imaging diagnosis of spondyloarthritis (SpA), the relative advantages of various available imaging techniques remain unclear. The aim of this study is to assess the current use of imaging in the diagnosis of SpA and to provide suitable recommendations for the use of imaging as an outcome measure as defined in the Assessment in SpondyloArthritis international Society (ASAS) criteria. EVIDENCE ACQUISITION A systematic literature search regarding imaging in SpA was performed. Articles were assessed by two reviewers to identify and summarized key information pertaining to imaging in SpA. EVIDENCE SYNTHESIS The search identified 180 relevant articles. Conventional radiography (CR) (17 articles), ultrasound (US) (26 articles), conventional computed tomography (CT) (13 articles), spectral computed tomography (spectral CT) (2 articles), bone scintigraphy (24 articles), and magnetic resonance imaging (MRI) were assessed (98 articles). Sacroiliitis and enthesitis were the major imaging findings in SpA. Multiple studies assessed the feasibility, validity, or differences among imaging modalities for the diagnosis of SpA; however, comprehensive assessments were not available due to a paucity of prospective imaging studies. CR is a widely available, inexpensive initial approach to evaluate patients with suspected SpA. CT enables assessment of structural changes from chronic sacroiliitis including bony erosions, subchondral sclerosis, joint space narrowing, and ankyloses; however, both CR and CT modalities are insensitive for demonstrating early enthesitis and sacroiliitis in SpA. US mainly identifies appendicular enthesitis but is more limited with respect to the sacroiliac joints. Bone scintigraphy can identify sacroiliac joint lesions and semi-quantitatively assess active sacroiliitis. MRI optimally evaluates not only early enthesitis and sacroiliitis of SpA but also chronic structural changes to the sacroiliac joints. CONCLUSIONS More than one modality may be required for diagnostic and assessment of SpA depending upon disease characteristics and evolution. CR is a suitable initial examination while MRI is able to detect both early and late changes of SpA. A combination of CR and MRI is recommended for the diagnosis and assessment of SpA.
Collapse
|
25
|
Radiation dose reduction: comparative assessment of publication volume between interventional and diagnostic radiology. Diagn Interv Radiol 2017; 23:223-226. [PMID: 28287072 DOI: 10.5152/dir.2016.16196] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
PURPOSE We aimed to quantify and compare awareness regarding radiation dose reduction within the interventional radiology and diagnostic radiology communities. METHODS Abstracts accepted to the annual meetings of the Society of Interventional Radiology (SIR), the Cardiovascular and Interventional Radiological Society of Europe (CIRSE), the Radiological Society of North America (RSNA), and the European Congress of Radiology (ECR) between 2005 and 2015 were analyzed using the search terms "interventional/computed tomography" and "radiation dose/radiation dose reduction." A PubMed query using the above-mentioned search terms for the years of 2005-2015 was performed. RESULTS Between 2005 and 2015, a total of 14 520 abstracts (mean, 660±297 abstracts) and 80 614 abstracts (mean, 3664±1025 abstracts) were presented at interventional and diagnostic radiology meetings, respectively. Significantly fewer abstracts related to radiation dose were presented at the interventional radiology meetings compared with the diagnostic radiology meetings (162 abstracts [1% of total] vs. 2706 [3% of total]; P < 0.001). On average 15±7 interventional radiology abstracts (range, 6-27) and 246±105 diagnostic radiology abstracts (range, 112-389) pertaining to radiation dose were presented at each meeting. The PubMed query revealed an average of 124±39 publications (range, 79-187) and 1205±307 publications (range, 829-1672) related to interventional and diagnostic radiology dose reduction per year, respectively (P < 0.001). CONCLUSION The observed increase in the number of abstracts regarding radiation dose reduction in the interventional radiology community over the past 10 years has not mirrored the increased volume seen within diagnostic radiology, suggesting that increased education and discussion about this topic may be warranted.
Collapse
|
26
|
Hydrochloric acid-enhanced radiofrequency ablation for treating a large hepatocellular carcinoma with spontaneous rapture: a case report. CHINESE JOURNAL OF CANCER 2017; 36:1. [PMID: 28061892 PMCID: PMC5219733 DOI: 10.1186/s40880-016-0161-8] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Accepted: 10/10/2016] [Indexed: 12/30/2022]
Abstract
Background A ruptured hepatocellular carcinoma (HCC) is often fatal. In addition to surgery and transarterial embolization, radiofrequency ablation (RFA) might be another option for treating a ruptured HCC. Unfortunately, conventional RFA has a limited ablation zone; as such, it is rarely used to treat ruptured tumors. Case presentation This case was a 60-year-old man who had a large, ruptured HCC in which hydrochloric acid (HCl)-enhanced RFA successfully controlled the bleeding and made the tumor completely necrotic. Conclusion Considering the effectiveness of HCl-enhanced RFA in achieving hemostasis and tumor ablation, it might be a new option for treating large, ruptured HCCs.
Collapse
|
27
|
The diagnostic value of non-contrast enhanced quiescent interval single shot (QISS) magnetic resonance angiography at 3T for lower extremity peripheral arterial disease, in comparison to CT angiography. J Cardiovasc Magn Reson 2016; 18:71. [PMID: 27760564 PMCID: PMC5072342 DOI: 10.1186/s12968-016-0294-6] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2016] [Accepted: 10/07/2016] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND The high incidence of renal insufficiency in patients with Peripheral Arterial Disease raises the concern for nephrogenic systemic fibrosis (NSF) with respect to contrast enhanced MRA. The risk of NSF is eliminated with non-contrast enhanced magnetic resonance angiography. The purpose of the current study is to compare image quality and diagnostic performance of non-contrast enhanced Quiescent Interval Single Shot (QISS) magnetic resonance angiography at 3 T versus CT angiography for evaluation of lower extremity Peripheral Arterial Disease (PAD). METHODS 32 consecutive patients (23 male, 9 female, age range 40-81 years, average age 61.97 years) with clinically suspected lower extremity PAD underwent QISS MRA and CTA. 19 of 32 patients underwent Digital Subtraction Angiography (DSA). Image quality of MRA was compared with CTA by two radiologists with 10 and 8 years' experience according to a 4-point scale. The Kappa test was used to determine the intermodality agreement between MRA and CTA in stenosis assessment, and interobserver agreement with each method. Sensitivity and specificity of CTA and MRA in detecting hemodynamically significant stenosis (≥50 %) were compared, with DSA serving as reference standard when available. RESULTS Image quality of QISS MRA was rated 3.70 ± 0.49 by reader 1, and 3.72 ± 0.47 by reader 2, significantly lower than that of CTA (3.80 ± 0.44 and 3.82 ± 0.42, P < 0.001 for both readers). Intermodality agreement between MRA and CTA was excellent for assessment of stenosis (Kappa = 0.923 ± 0.013 for reader 1, 0.930 ± 0.012 for reader 2). Interobserver agreement was 0.936 ± 0.012 for CTA and 0.935 ± 0.011 for MRA. For readers 1 and 2 respectively, the sensitivity of QISS was 94.25 and 93.26 % (versus 90.11 and 89.13 % for CTA, P > 0.05), and specificity of QISS was 96.70 and 97.75 % (versus 96.55 and 96.51 % for CTA, P > 0.05). For heavily calcified segments, sensitivity of QISS (95.83 and 95.83 %) was significantly higher than that of CTA (74.19 and 76.67 %, P < 0.05). CONCLUSION QISS is a reliable alternative to CTA for evaluation of lower extremity PAD, and may be suitable as a first-line screening examination in patients with contraindications to intravenous contrast administration.
Collapse
|
28
|
Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensions. Eur J Radiol 2016; 85:1773-1777. [PMID: 27666615 DOI: 10.1016/j.ejrad.2016.07.022] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2016] [Revised: 07/27/2016] [Accepted: 07/31/2016] [Indexed: 01/25/2023]
Abstract
PURPOSE To evaluate the feasibility and clinical robustness of zoomed diffusion-weighted echo planar imaging (z-EPI) relative to conventional single-shot EPI (c-EPI) for DWI of the kidneys. MATERIALS AND METHODS This retrospective study was approved by the institutional research ethics board. 66 patients (median age 58.5 years±13.4, range 23-83 years, 45 men, 21 women) undergoing 3T (Magnetom Skyra(®), Siemens Healthcare, Erlangen, Germany) using a dynamic parallel transmit array (TimTX TrueShape, Siemens Healthcare, Erlangen, Germany) for renal MRI were included in this study. Both c-EPI and z-EPI images were obtained. For z-EPI, a two-dimensional spatially-selective radiofrequency (RF) pulse was applied for echo planar imaging with the FOV reduced by a factor of 3. Two radiologists, blinded to clinical data and scan parameters evaluated the images with respect to their diagnostic confidence, overall preference, overall image quality, delineation of the kidney, spatial distortion, and image blur. Sequences were compared using a paired Wilcoxon test. ADC values for the upper pole, mid-zone, lower pole of the normal kidneys were compared between sequences as well as ADC values for renal lesions, using a paired t-test. RESULTS With z-EPI, the kidney was significantly better delineated with sharper boundaries, less image blur and distortion, and overall better image quality relative to c-EPI (all p<0.001). The z-EPI technique led to greater diagnostic confidence than c-EPI (p=0.020). z-EPI was preferred to c-EPI in 60 cases (90.9%, 60/66). No statistically significant differences in the ADC values of renal parenchyma or of renal lesions were observed between the two sequences (all p>0.05). CONCLUSION Image quality, distortion, and susceptibility artifacts might be improved by using z-EPI rather than c-EPI for DWI of the kidney.
Collapse
|
29
|
Abstract
AIM To evaluate the role of diffusion-weighted MRI (DW-MRI) in detecting and differentiating acute from chronic bowel inflammation in patients with Crohn's disease (CD). MATERIALS AND METHODS MR-enteroclysis examinations with DW-MRI were reviewed from 24 patients with histologically proven CD. Segments of bowel were evaluated for acute and chronic inflammation in three different reviews of the MRI images: T2w alone, T2w + DWI, and T2w + CET1w. Mean ADC values of normal bowel segments, as well as bowel segments with acute and chronic inflammation were calculated and compared. Analyses of receiver-operating characteristic (ROC) curve were performed. RESULTS Hundred and forty four bowel segments in total were reviewed. Inflammation was present in 45 segments. Acute inflammation was present in 31 segments, chronic inflammation in 14. 98 bowel segments showed no inflammatory activity. Sensitivity and specificity for differentiation between normal and inflamed bowel segments was 0.6, 0.67, and 0.80 on T2w, T2w + DWI, and T2w + CET1w datasets, respectively. Specificities for differentiation between normal and inflamed bowel segments were 0.96, 0.96, and 0.98. Sensitivities for differentiation between acute and chronically inflamed bowel segments were 0.85, 0.91, and 0.96, and specificities were 0.88, 0.89, and 1.0, respectively. The mean ADC value of normal bowel (2.18 ± 0.37 × 10(-3) mm(2)/s) was statistically significantly greater than the mean value of inflamed bowel segments (p < 0.001). The mean ADC value of acutely inflamed bowel segments was statistically significantly lower than that of chronically inflamed bowel segments (1.09 ± 0.18 × 10(-3) vs. 1.55 ± 0.21 × 10(-3) mm(2)/s) (p < 0.001). Estimated area under the ROC curve for the diagnosis of acute vs. chronic inflammation was 0.950. A threshold of ADC value of 1.41 × 10(-3) mm(2)/s was optimal for calculation of sensitivity and specificity. CONCLUSION DW-MRI improves detection and differentiation of acute vs. chronic inflammatory changes of the bowel in patients with CD compared to T2w-images alone.
Collapse
|
30
|
Semi-automatic Volumetric Measurement of Treatment Response in Hepatocellular Carcinoma After Trans-arterial Chemoembolization. Anticancer Res 2016; 36:4353-4358. [PMID: 27466556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2016] [Accepted: 07/11/2016] [Indexed: 06/06/2023]
Abstract
AIM To perform a quantitative, volumetric analysis of therapeutic effects of trans-arterial chemoembolization (TACE) in hepatocellular carcinoma (HCC) patients. PATIENTS AND METHODS Entire tumor volume and a subset of hypervascular tumor portions were analyzed pre- and post-TACE in magnetic resonance imaging datasets of 22 HCC patients using a semi-automated segmentation and evaluation tool from the Medical Imaging Interaction Toolkit. Results were compared to mRECIST measurements and inter-reader variability was assessed. RESULTS Mean total tumor volume increased statistical significantly after TACE (84.6 ml pre- vs. 97.1 ml post-TACE, p=0.03) while hypervascular tumor volume decreased from 9.1 ml pre- to 3.7 ml post-TACE (p=0.0001). Likewise, mRECIST diameters decreased significantly after therapy (44.2 vs. 15.4 mm). In the inter-reader assessment, overlap errors were 12.3-17.7% for entire and 36.3-64.2% for the enhancing tumor volume. CONCLUSION Quantification of therapeutic changes after TACE therapy is feasible using a semi-automated segmentation and evaluation tool. Following TACE, hypervascular tumor volume decreases significantly.
Collapse
|
31
|
Association of mucoid degeneration of anterior cruciate ligament with knee meniscal and cartilage damage. Osteoarthritis Cartilage 2015; 23:1543-50. [PMID: 25907861 DOI: 10.1016/j.joca.2015.04.013] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2014] [Revised: 04/06/2015] [Accepted: 04/14/2015] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To assess the prevalence of anterior cruciate ligament (ACL) mucoid degeneration in patients referred for routine knee magnetic resonance (MR) imaging, and its association with age and structural joint damage. METHOD Four independent radiologists assessed 413 consecutive knee MR examinations for the presence of a normal or ruptured ACL, or ACL mucoid degeneration. Knees with ACL mucoid degeneration were frequency matched by age, sex, and MR field strength with consecutive control knees with a normal ACL (1:2 ratio). Differences in meniscal and cartilage damage of the tibiofemoral compartments, as determined by the Whole-Organ MR Imaging Score (WORMS) system, were compared by Mann-Whitney U tests. Multivariable logistic regression analysis identified the association of ACL mucoid degeneration with severe MTFC cartilage damage (WORMS≥5). RESULTS Patients with ACL mucoid degeneration (n = 36; 36% males; median age 55.5 years, range: 26-81) were older than patients with a normal (P < 0.001) or ruptured ACL (P < 0.001), without sex predilection (P = 0.76), and were more frequently diagnosed at 3 T (12%) compared to 1.5 T (2%). Knees with ACL mucoid degeneration had statistically significantly more medial meniscal (P < 0.001) and central and posterior medial tibiofemoral compartment (MTFC) cartilage (P < 0.001) damage compared with control knees (n = 72), but there were no differences in patients ≤50 years (P = 0.09 and 0.32, respectively). In multivariable logistic regression, severe MTFC cartilage damage (WORMS≥5) was significantly associated with ACL mucoid degeneration (odds ratio 4.09, 95% confidence interval 1.29-12.94, P = 0.016). CONCLUSION There is a strong association between ACL mucoid degeneration and cartilage damage in the central and posterior MTFC, especially in patients >50 years.
Collapse
|
32
|
Small Field-of-view single-shot EPI-DWI of the prostate: Evaluation of spatially-tailored two-dimensional radiofrequency excitation pulses. Z Med Phys 2015; 26:168-76. [PMID: 26300045 DOI: 10.1016/j.zemedi.2015.06.013] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2015] [Revised: 06/17/2015] [Accepted: 06/22/2015] [Indexed: 11/24/2022]
Abstract
PURPOSE Spatially-tailored (RF) excitation pulses in echo-planar imaging (EPI), combined with a decreased FOV in the phase-encoding direction, enable a reduction of k-space acquisition lines, which shortens the echo train length (ETL) and reduces susceptibility artifacts. The purpose of this study was to evaluate the image quality of a zoomed EPI (z-EPI) sequence in diffusion-weighted imaging (DWI) of the prostate in comparison to a conventional single-shot EPI using single-channel (c-EPI1) and multi-channel (c-EPI2) RF excitation, with and without use of an endorectal coil. MATERIALS AND METHODS 33 consecutive patients (mean age: 61 +/- 9 years; mean PSA: 8.67±6.23 ng/ml) with examinations between 10/2012 and 02/2014 were analyzed in this retrospective study. In 26 of 33 patients the initial multiparametric (mp)-MRI was performed on a whole-body 3T scanner (Magnetom Trio, Siemens, Erlangen, Germany) using an endorectal coil (c (conventional)-EPI1). Zoomed-EPI (Z-EPI) examinations of these patients and a complete mp-MRI protocol including c-EPI2 of 7 additional patients were carried out on another 3T wb MR scanner with two-channel dynamic parallel transmit capability (Magnetom Skyra with TimTX TrueShape, Siemens). For z-EPI, the one-dimensional spatially selective RF excitation pulse was replaced by a two-dimensional RF pulse. Degree of image blur and susceptibility artifacts (0=not present to 3= non-diagnostic), maximum image distortion (mm), apparent diffusion coefficient (ADC) values, as well as overall scan preference were evaluated. SNR maps were generated to compare c-EPI2 and z-EPI. RESULTS Overall image quality of z-EPI was preferred by both readers in all examinations with a single exception. Susceptibility artifacts were rated significantly lower on z-EPI compared to both other methods (z-EPI vs c-EPI1: p<0.01; z-EPI vs c-EPI2: p<0.01) as well as image blur (z-EPI vs c-EPI1: p<0.01; z-EPI vs c-EPI2: p<0.01). Image distortion was not statistically significantly reduced with z-EPI (z-EPI vs c-EPI1: p=0.12; z-EPI vs c-EPI2: p=0.42). Interobserver agreement for ratings of susceptibility artifacts, image blur and overall scan preference was good. SNR was higher for z-EPI than for c-EPI1 (n=1). CONCLUSION Z-EPI leads to significant improvements in image quality and artifacts as well as image blur reduction improving prostate DWI and enabling accurate fusion with conventional sequences. The improved fusion could lead to advantages in the field of MRI-guided biopsy suspicous lesions and performance of locally ablative procedures for prostate cancer.
Collapse
|
33
|
Hepatic abscess caused by trans-gastric migration of a fishbone. Surg Infect (Larchmt) 2015; 16:206-8. [PMID: 24815531 DOI: 10.1089/sur.2013.254] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
|
34
|
Metal artefact reduction in MRI at both 1.5 and 3.0 T using slice encoding for metal artefact correction and view angle tilting. Br J Radiol 2015; 88:20140601. [PMID: 25613398 DOI: 10.1259/bjr.20140601] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To compare metal artefact reduction in MRI at both 3.0 T and 1.5 T using different sequence strategies. METHODS Metal implants of stainless steel screw and plate within agarose phantoms and tissue specimens as well as three patients with implants were imaged at both 1.5 T and 3.0 T, using view angle tilting (VAT), slice encoding for metal artefact correction with VAT (SEMAC-VAT) and conventional sequence. Artefact reduction in agarose phantoms was quantitatively assessed by artefact volume measurements. Blinded reads were conducted in tissue specimen and human imaging, with respect to artefact size, distortion, blurring and overall image quality. Wilcoxon and Friedman tests for multiple comparisons and intraclass correlation coefficient (ICC) for interobserver agreement were performed with a significant level of p < 0.05. RESULTS Compared with conventional sequences, SEMAC-VAT significantly reduced metal artefacts by 83% ± 9% for the screw and 89% ± 3% for the plate at 1.5 T; 72% ± 7% for the screw and 38% ± 13% for the plate at 3.0 T (p < 0.05). In qualitative analysis, SEMAC-VAT allowed for better visualization of tissue structures adjacent to the implants and produced better overall image quality with good interobserver agreement for both tissue specimen and human imaging (ICC = 0.80-0.99; p < 0.001). In addition, VAT also markedly reduced metal artefacts compared with conventional sequence, but was inferior to SEMAC-VAT. CONCLUSION SEMAC-VAT and VAT techniques effectively reduce artefacts from metal implants relative to conventional imaging at both 1.5 T and 3.0 T. ADVANCES IN KNOWLEDGE The feasibility of metal artefact reduction with SEMAC-VAT was demonstrated at 3.0-T MR. SEMAC-VAT significantly reduced metal artefacts at both 1.5 and 3.0 T. SEMAC-VAT allowed for better visualization of the tissue structures adjacent to the metal implants. SEMAC-VAT produced consistently better image quality in both tissue specimen and human imaging.
Collapse
|
35
|
CAIPIRINHA-Dixon-TWIST (CDT)-volume-interpolated breath-hold examination (VIBE) for dynamic liver imaging: Comparison of gadoterate meglumine, gadobutrol and gadoxetic acid. Eur J Radiol 2014; 83:2007-12. [PMID: 25172427 DOI: 10.1016/j.ejrad.2014.08.003] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2014] [Revised: 07/08/2014] [Accepted: 08/07/2014] [Indexed: 11/17/2022]
|
36
|
The issues and tentative solutions for contrast-enhanced magnetic resonance imaging at ultra-high field strength. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2014; 6:559-73. [DOI: 10.1002/wnan.1291] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2014] [Revised: 07/07/2014] [Accepted: 07/20/2014] [Indexed: 12/20/2022]
|
37
|
23Na-magnetic resonance imaging of the human lumbar vertebral discs: in vivo measurements at 3.0 T in healthy volunteers and patients with low back pain. Spine J 2014; 14:1343-50. [PMID: 24472875 DOI: 10.1016/j.spinee.2014.01.031] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2013] [Revised: 12/12/2013] [Accepted: 01/17/2014] [Indexed: 02/09/2023]
Abstract
BACKGROUND CONTEXT 1H magnetic resonance imaging (MRI) of the spine can rule out common causes of low back pain (LBP), such as disc protrusions or nerve root compression; however, no significant causal relation exists between morphology and the extent of symptoms. Functional MRI techniques, such as 23Na, may provide additional information, allowing indirect assessment of vertebral glycosaminoglycan concentrations, decreases in which are associated with early degenerative changes. PURPOSE To evaluate 23Na-MRI of asymptomatic healthy volunteers and symptomatic patients with LPB and correlate the results to the Pfirrmann classification of MRI disc morphology. STUDY DESIGN Retrospective cohort study at an academic medical center. PATIENT SAMPLE Two groups were studied: (1) 55 healthy volunteers (31 men, 24 women; mean age 28.8 years) and (2) 12 patients (6 men, 6 women; mean age: 35.3 years) with a recent history of LBP. METHODS Lumbar spines of the aforementioned groups were examined on a 3.0 T MRI scanner with morphological 1H and 23Na imaging. Intervertebral disc (IVD) 23Na at each level was normalized (23Nanorm). Distribution and differences between mean 23Nanorm corresponding to each Pfirrmann classification were evaluated in the two study groups (analysis of variance). Linear correlations between 23Nanorm, body mass index (BMI), and age were assessed (Pearson correlation coefficient). Gender-dependent differences were evaluated (paired t test). OUTCOME MEASURES Physiological measure: IVD 23Nanorm as determined by 23Na-MRI. RESULTS A normal distribution of 23Nanorm was confirmed for both groups (p=.072 and p=.073, respectively). The mean Pfirrmann score statistically significantly differed between them (p<.0001). 23Nanorm was statistically significantly reduced in degenerated IVDs (Pfirrmann scores 4+5) (p<.0001). No statistically significant differences were seen for the mean 23Nanorm of IVDs with the same Pfirrmann score in healthy volunteers and patients (.469<p<.967). Age (0.007<R2<0.202) and BMI (0.074<R2<0.288) showed either weak or no correlation to 23Nanorm. Mean 23Nanorm was significantly (p=.0002) greater in women relative to men. CONCLUSIONS The results underline the feasibility and robustness of 23Na-MRI of human IVDs and affirm, in a large cohort, decreases in 23Na IVD content seen with disc degeneration.
Collapse
|
38
|
Enhancement characteristics and impact on image quality of two gadolinium chelates at equimolar doses for time-resolved 3-Tesla MR-angiography of the calf station. PLoS One 2014; 9:e99079. [PMID: 24893292 PMCID: PMC4043962 DOI: 10.1371/journal.pone.0099079] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2013] [Accepted: 05/10/2014] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To compare enhancement characteristics and image quality of two macrocyclic gadolinium chelates, gadoterate meglumine and gadobutrol, in low-dose, time-resolved MRA of the calf station. MATERIALS AND METHODS 100 consecutive patients with peripheral arterial disease (stages II-IV) were retrospectively analysed. Fifty patients were included in each group - 32 men and 18 women for gadobutrol (mean age 67 years) and 34 men, 16 women for gadoterate meglumine (mean age 64 years). 0.03 mmol/kg bw of either gadobutrol or gadoterate meglumine was injected. Gadobutrol was diluted 1 ∶ 1 with normal saline (0.9% NaCl) to provide similar injection volume and bolus geometry compared to the undiluted 0.5 M dose of gadoterate meglumine. Signal-to-noise-ratio (SNR), contrast-to-noise-ratio (CNR) and image quality were analysed and compared between the two groups. RESULTS Mean SNR ranged from 83.0 ± 46.7 (peroneal artery) to 96.4 ± 64.5 (anterior tibial artery) for gadobutrol, and from 37.6 ± 13.8 (peroneal artery) to 45.3 ± 16.4 (anterior tibial artery) for the gadoterate meglumine group (p<0.0001). CNR values ranged from 30.1 ± 20.1 (peroneal artery) to 37.6 ± 26.0 (anterior tibial artery) for gadobutrol and from 14.9 ± 8.0 (peroneal artery) to 18.6 ± 16.4 (anterior tibial artery) for gadoterate meglumine (p<0.0001). No significant difference in image quality was found except for the peroneal arteries (p = 0.006 and p = 0.04). Interreader agreement was excellent (kappa 0.87-0.93). CONCLUSION The significantly better enhancement as assessed by SNR and CNR provided by gadobutrol compared to gadoterate meglumine does not translate into substantial differences in image quality in an equimolar, low-dose, time-resolved MRA protocol of the calves.
Collapse
|
39
|
Multi-parametric MRI of rectal cancer - do quantitative functional MR measurements correlate with radiologic and pathologic tumor stages? Eur J Radiol 2014; 83:1036-1043. [PMID: 24791649 DOI: 10.1016/j.ejrad.2014.03.012] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2013] [Revised: 02/27/2014] [Accepted: 03/11/2014] [Indexed: 12/13/2022]
Abstract
PURPOSE The purpose of this study is two-fold. First, to evaluate, whether functional rectal MRI techniques can be analyzed in a reproducible manner by different readers and second, to assess whether different clinical and pathologic T and N stages can be differentiated by functional MRI measurements. MATERIALS AND METHODS 54 patients (38 men, 16 female; mean age 63.2 ± 12.2 years) with pathologically proven rectal cancer were included in this retrospective IRB-approved study. All patients were referred for a multi-parametric MRI protocol on a 3 Tesla MR-system, consisting of a high-resolution, axial T2 TSE sequence, DWI and perfusion imaging (plasma flow -s PFTumor) prior to any treatment. Two experienced radiologists evaluated the MRI measurements, blinded to clinical data and outcome. Inter-reader correlation and the association of functional MRI parameters with c- and p-staging were analyzed. RESULTS The inter-reader correlation for lymph node (ρ 0.76-0.94; p<0.0002) and primary tumor (ρ 0.78-0.92; p<0.0001) apparent diffusion coefficient and plasma flow (PF) values was good to very good. PFTumor values decreased with cT stage with significant differences identified between cT2 and cT3 tumors (229 versus 107.6 ml/100ml/min; p=0.05). ADCTumor values did not differ significantly. No substantial discrepancies in lymph node ADCLn values or short axis diameter were found among cN1-3 stages, whereas PFLn values were distinct between cN1 versus cN2 stages (p=0.03). In the patients without neoadjuvant RCT no statistically significant differences in the assessed functional parameters on the basis of pathologic stage were found. CONCLUSION This study illustrates that ADC as well as MR perfusion values can be analyzed with good interobserver agreement in patients with rectal cancer. Moreover, MR perfusion parameters may allow accurate differentiation of tumor stages. Both findings suggest that functional MRI parameters may help to discriminate T and N stages for clinical decision making.
Collapse
|
40
|
Zoomed EPI-DWI of the pancreas using two-dimensional spatially-selective radiofrequency excitation pulses. PLoS One 2014; 9:e89468. [PMID: 24594702 PMCID: PMC3940598 DOI: 10.1371/journal.pone.0089468] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2013] [Accepted: 01/20/2014] [Indexed: 12/20/2022] Open
Abstract
Background Implementation of DWI in the abdomen is challenging due to artifacts, particularly those arising from differences in tissue susceptibility. Two-dimensional, spatially-selective radiofrequency (RF) excitation pulses for single-shot echo-planar imaging (EPI) combined with a reduction in the FOV in the phase-encoding direction (i.e. zooming) leads to a decreased number of k-space acquisition lines, significantly shortening the EPI echo train and potentially susceptibility artifacts. Purpose To assess the feasibility and image quality of a zoomed diffusion-weighted EPI (z-EPI) sequence in MR imaging of the pancreas. The approach is compared to conventional single-shot EPI (c-EPI). Material and Methods 23 patients who had undergone an MRI study of the abdomen were included in this retrospective study. Examinations were performed on a 3T whole-body MR system (Magnetom Skyra, Siemens) equipped with a two-channel fully dynamic parallel transmit array (TimTX TrueShape, Siemens). The acquired sequences consisted of a conventional EPI DWI of the abdomen and a zoomed EPI DWI of the pancreas. For z-EPI, the standard sinc excitation was replaced with a two-dimensional spatially-selective RF pulse using an echo-planar transmit trajectory. Images were evaluated with regard to image blur, respiratory motion artifacts, diagnostic confidence, delineation of the pancreas, and overall scan preference. Additionally ADC values of the pancreatic head, body, and tail were calculated and compared between sequences. Results The pancreas was better delineated in every case (23/23) with z-EPI versus c-EPI. In every case (23/23), both readers preferred z-EPI overall to c-EPI. With z-EPI there was statistically significantly less image blur (p<0.0001) and respiratory motion artifact compared to c-EPI (p<0.0001). Diagnostic confidence was statistically significantly better with z-EPI (p<0.0001). No statistically significant differences in calculated ADC values were observed between the two sequences. Conclusion Zoomed diffusion-weighted EPI leads to substantial image quality improvements with reduction of susceptibility artifacts in pancreatic DWI.
Collapse
|
41
|
[Value of new MR techniques in MR-PET]. Radiologe 2013; 53:1118-24. [PMID: 24221697 DOI: 10.1007/s00117-013-2559-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The unparalleled soft tissue contrast of magnetic resonance imaging (MRI) and the functional information obtainable with 18-F fluorodeoxyglucose positron emission tomography (FDG-PET) render MR-PET well-suited for oncological and psychiatric imaging. The lack of ionizing radiation with MRI also makes MR-PET a promising modality for oncology patients requiring frequent follow-up and pediatric patients. Lessons learned with PET computed tomography (CT) over the last few years do not directly translate to MR-PET. For example, in PET-CT the Hounsfield units derived from CT are used for attenuation correction (AC). As 511 keV photons emitted in PET examinations are attenuated by the patient's body CT data are converted directly to linear attenuation coefficients (LAC); however, proton density measured by MRI is not directly related to the radiodensity or LACs of biological tissue. Thus, direct conversion to LAC data is not possible making AC more challenging in simultaneous MRI-PET scanning. In addition to these constraints simultaneous MRI-PET acquisitions also improve on some solutions to well-known challenges of hybrid imaging techniques, such as limitations in motion correction. This article reports on initial clinical experiences with simultaneously acquired MRI-PET data, focusing on the potential benefits and limitations of MRI with respect to motion correction as well as metal and attenuation correction artefacts.
Collapse
|
42
|
Nonenhanced ECG-gated quiescent-interval single shot MRA: Image quality and stenosis assessment at 3 tesla compared with contrast-enhanced MRA and digital subtraction angiography. J Magn Reson Imaging 2013; 39:1486-93. [DOI: 10.1002/jmri.24324] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2013] [Accepted: 07/05/2013] [Indexed: 11/11/2022] Open
|
43
|
Comparison of Dynamic and Liver-Specific Gadoxetic Acid Contrast-Enhanced MRI versus Apparent Diffusion Coefficients. PLoS One 2013; 8:e61898. [PMID: 23805174 PMCID: PMC3689764 DOI: 10.1371/journal.pone.0061898] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2012] [Accepted: 03/14/2013] [Indexed: 01/30/2023] Open
Abstract
Background Hepatic lesions often present diagnostic connundrums with conventional MR techniques. Hepatobiliary phase contrast-enhanced imaging with gadoxetic acid can aid in the characterization of such lesions. However, quantitative measures describing late-phase enhancement must be assessed relative to their accuracy of hepatic lesion classification. Purpose: To compare quantitative parameters in gadoxetic acid contrast-enhanced dynamic and hepatobiliary phase imaging versus apparent diffusion coefficients in hepatic lesion characterization. Material and Methods 57 patients with focal hepatic lesions on gadoxetic acid MR were included. Lesion enhancement at standard post-contrast time points and in the hepatobiliary phase (HB; 15 and 25 minutes post-contrast) was assessed via calculation of contrast (CR) and enhancement ratios (ER). Apparent diffusion coefficient (ADC) values were also obtained. Values for these parameters were compared among lesions and ROC analyses performed. Results: HB enhancement was greatest with FNH and adenomas. HB ER parameters but not HB CR could distinguish HCC from benign entities (0.9 ER ROC AUC versus 0.5 CR ROC AUC). There was no statistically significant difference found between the 15 and 25 minutes HB time points in detection of any lesion (p>0.4). ADC values were statistically significantly higher with hemangiomas (p<0.05) without greater accuracy in lesion detection relative to HB phase parameters. Conclusion Hepatobiliary phase gadoxetic acid contrast-enhanced MR characterizes focal hepatic lesions more accurately than ADC and conventional dynamic post-contrast time point enhancement parameters. ER values are generally superior to CR. No discernible benefit of 25 minute versus 15 minute delayed imaging is demonstrated.
Collapse
|
44
|
Enhancement in a brain glioma model: A comparison of half-dose gadobenate dimeglumine versus full-dose gadopentetate dimeglumine at 1.5 and 3 T. J Magn Reson Imaging 2013; 38:306-11. [DOI: 10.1002/jmri.23965] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2012] [Accepted: 10/23/2012] [Indexed: 11/09/2022] Open
|
45
|
Technical considerations in MR angiography: An image-based guide. J Magn Reson Imaging 2013; 37:1326-41. [DOI: 10.1002/jmri.24174] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2012] [Accepted: 03/20/2013] [Indexed: 11/09/2022] Open
|
46
|
Spinal cord needle tract following epidural steroid injection. J Vasc Interv Radiol 2013; 23:1543-4. [PMID: 23101928 DOI: 10.1016/j.jvir.2012.07.020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2012] [Revised: 07/16/2012] [Accepted: 07/24/2012] [Indexed: 10/27/2022] Open
|
47
|
3T Renal 23Na-MRI: effects of desmopressin in patients with central diabetes insipidus. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2013; 27:47-52. [DOI: 10.1007/s10334-013-0377-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2013] [Revised: 03/12/2013] [Accepted: 03/13/2013] [Indexed: 12/01/2022]
|
48
|
Assessment of coronary microvascular dysfunction in hypertrophic cardiomyopathy: first-pass myocardial perfusion cardiovascular magnetic resonance imaging at 1.5 T. Clin Radiol 2013; 68:676-82. [PMID: 23566329 DOI: 10.1016/j.crad.2013.01.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2012] [Revised: 12/26/2012] [Accepted: 01/09/2013] [Indexed: 11/26/2022]
Abstract
AIM To evaluate the integrity of the coronary microvasculature in patients with hypertrophic cardiomyopathy (HCM) using first-pass magnetic resonance perfusion imaging. MATERIALS AND METHODS Twenty-two patients with HCM and 13 healthy volunteers underwent cardiac magnetic resonance imaging (CMR) at rest. Imaging protocols included short axis cine, first-pass myocardial perfusion, and late-phase contrast-enhanced imaging. Left ventricular end-diastolic wall thickness (EDTH), myocardial thickening, maximal upslope of time-intensity curve (slopemax), and late myocardial gadolinium enhancement (LGE) were assessed for each myocardial segment. The differences in slopemax, myocardial thickening, and EDTH between healthy volunteers and HCM patients were evaluated as were differences among hypertrophic segments of different severities (mild, moderate, and severe hypertrophy) in a one-way analysis of variance analysis. The differences in slopemax, myocardial thickening, and EDTH between the segments with and without LGE were compared by independent-sample t-test. A Pearson correlation test was used to determine the relationships between slopemax, EDTH, and myocardial thickening. RESULTS Slopemax was statistically significantly less in HCM patients; the degree of myocardial thickening was also significantly reduced (p < 0.001). Slopemax and the degree of thickening statistically significantly decreased with increasing degrees of myocardial hypertrophy (p < 0.05). Differences in slopemax, myocardial thickening, and EDTH were observed between segments with and without LGE (p < 0.05). Slopemax and myocardial thickening were negatively correlated with EDTH. CONCLUSION First-pass myocardial perfusion CMR with slopemax measurements demonstrates microvascular coronary dysfunction in patients with HCM, a determination that may aid in risk stratification, therapeutic planning, and determination of prognosis for HCM.
Collapse
|
49
|
Assessment of the renal corticomedullary (23)Na gradient using isotropic data sets. Acad Radiol 2013; 20:407-13. [PMID: 23498980 DOI: 10.1016/j.acra.2012.10.009] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2012] [Revised: 09/27/2012] [Accepted: 10/03/2012] [Indexed: 11/19/2022]
Abstract
RATIONALE AND OBJECTIVES (23)Na magnetic resonance imaging is a promising technique for the noninvasive imaging of renal function. Past investigations of the renal corticomedullary [(23)Na] gradient have relied on imaging only in the coronal plane and on cumbersome calculations of [(23)Na], which require the use of external phantoms. The aim of this study is therefore two-fold: to use an isotropic three-dimensional data set to compare coronal measurements of renal [(23)Na] relative to measurements obtained in planes along the corticomedullary gradients and to investigate cerebrospinal fluid (CSF) (23)Na signal as an internal reference standard, obviating the need for time-intensive [(23)Na] calculations. MATERIALS AND METHODS Nominal isotropic three-dimensional (23)Na MRI data sets were obtained in 14 healthy volunteers before and after a water load. Images were reconstructed in the coronal plane and in planes angled along the direction of the corticomedullary sodium gradients. [(23)Na] values and values of the corticomedullary [(23)Na] gradient were measured by placement of a linear region of interest along corticomedullary gradients in both the coronal/nonangled [(23)Na(non-ang)] and the angled [(23)Na(ang)] image reconstructions. CSF [(23)Na] was also acquired at multiple levels. Ratios of renal (23)Na and CSF (23)Na signal were calculated to construct a semiquantitative parameter, [(23)NaCSF]. Results of water stimulation as measured by [(23)NaCSF] and [(23)Na(ang)] were then compared. RESULTS Mean values of [(23)Na(ang)] were statistically significantly greater than those of [(23)Na(non-ang)] (P < .0001), although these values were linearly correlated (R = 0.553, P < .0001) and exhibited similar extents of decreases in absolute terms (P = .2) and in terms of the corticomedullary gradient following the water load. CSF [(23)Na] did not statistically significantly differ at any level after the water load (P > .5) but tended to increase in the cranial direction (P < .001). [(23)NaCSF] measures demonstrated analogous statistical properties to [(23)Na(ang)] before and after the water load. CONCLUSIONS Assessment of renal corticomedullary [(23)Na] gradients using isotropic data sets with image reconstructions along the gradients is likely more accurate than measurements in the coronal plane. Because CSF [(23)Na] differs based on anatomic levels, such measures are useful as an internal reference only if region of interest placement is consistent. With this caveat in mind, normalization of renal to CSF (23)Na signal provides a feasible, less cumbersome alternative to [(23)Na] calculations in intraindividual studies.
Collapse
|
50
|
Quantitative in vivo 23Na MR imaging of the healthy human kidney: determination of physiological ranges at 3.0T with comparison to DWI and BOLD. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2013; 26:501-9. [PMID: 23475308 DOI: 10.1007/s10334-013-0369-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2012] [Revised: 01/25/2013] [Accepted: 01/29/2013] [Indexed: 11/29/2022]
Abstract
OBJECTIVES The purpose of this prospective study was to assess the normal physiologic ranges of the renal corticomedullary 23Na-concentration ([23Na]) gradient at 3.0T in healthy volunteers. The corticomedullary [23Na] gradient was correlated with other functional MR imaging parameters--blood oxygenation level dependent (BOLD) and diffusion-weighted imaging (DWI)--and to individual and physiologic parameters--age, gender, estimated glomerular filtration rate (eGFR), body mass index (BMI), and blood serum sodium concentration ([23Na]serum). METHODS AND MATERIALS 50 healthy volunteers (30 m, 20 w; mean age: 29.2 years) were included in this IRB-approved study, without a specific a priori preparation in regard to water or food intake. For 23Na-imaging a 3D density adapted, radial gradient echo (GRE)-sequence (spatial resolution=5×5×5 mm3) was used in combination with a dedicated 23Na-coil and 23Na-reference phantoms. [23Na] values of the corticomedullary [23Na] gradient were measured by placement of a linear region of interest (20×1 mm2) from the renal cortex in the direction of the renal medulla. By using external standard reference phantoms, [23Na] was calculated in mmol/L of wet tissue volume (mmol/l WTV). Axial diffusion-weighted images (spatial resolution=1.7×1.7×5.0 mm3) and 2D GRE BOLD images (spatial resolution=1.2×1.2×4.0 mm3) were acquired. Mean values±standard deviations for [23Na], apparent diffusion coefficient (ADC) values, and R2* values were computed for each volunteer. The corticomedullary 23Na-concentration gradient (in mmol/l/mm) was calculated along the area of linear concentration increase from the cortex in the direction of the medulla. Correlations between the [23Na] and DWI, BOLD, and the physiologic parameters were assessed with Pearson correlation coefficients. RESULTS The mean corticomedullary [23Na] for all healthy volunteers increased from the renal cortex (58±17 mmol/l WTV) in the direction of the medulla (99±18 mmol/l WTV). The inter-individual differences ranged from respective cortical and medullary values of 27 and 63 mmol/L WTV to 126 and 187 mmol/L WTV. No statistically significant differences in renal [23Na] were found based on differences in individual or physiologic parameters (age, gender, [23Na]serum, BMI, GFR). No ADC or R2* gradients were identified, and [23Na] did not correlate with these parameters. CONCLUSION Renal corticomedullary [23Na] values increase from the cortex in the direction of the medullary pyramid, demonstrating wide inter-individual ranges and no significant correlations with age, gender, [23Na]serum, BMI, GFR, ADC, or R2* values. For future clinical evaluations, an approach relying on renal stimulation (e.g. pharmacologically induced diuresis) may be applicable to account for wide inter-individual ranges of normal [23Na].
Collapse
|