1
|
Abstract
Di-2-ethylhexyl phthalate (DEHP) is commonly used in the manufacturing of plastic materials, including intravenous bags, blood storage bags, and medical-grade tubing. DEHP can leach from plastic medical products, which can result in inadvertent patient exposure. DEHP concentrations were measured in red blood cell units stored between 7 and 42 days (17-119 μg/ml). Using these concentrations as a guide, Langendorff-perfused rat heart preparations were acutely exposed to DEHP. Sinus activity remained stable with lower doses of DEHP (25-50 μg/ml), but sinus rate declined by 43% and sinus node recovery time (SNRT) prolonged by 56.5% following 30-min exposure to 100 μg/ml DEHP. DEHP exposure also exerted a negative dromotropic response, as indicated by a 69.4% longer PR interval, 108.5% longer Wenckebach cycle length (WBCL), and increased incidence of atrioventricular (AV) uncoupling (60-min exposure). Pretreatment with doxycycline partially rescued the effects of DEHP on sinus activity, but did not ameliorate the effects on AV conduction. DEHP exposure also prolonged the ventricular action potential and effective refractory period, but had no measurable effect on intracellular calcium transient duration. Follow-up studies using human-induced pluripotent stem cell-derived cardiomyocytes confirmed that DEHP slows electrical conduction in a time (15 min-3 h) and dose-dependent manner (10-100 μg/ml). Previous studies have suggested that phthalate toxicity is specifically attributed to metabolites of DEHP, including mono-2-ethylhexylphthalate. This study demonstrates that DEHP exposure also contributes to cardiac dysfunction in a dose- and time-dependent manner. Future work is warranted to investigate the impact of DEHP (and its metabolites) on human health, with special consideration for clinical procedures that employ plastic materials.
Collapse
|
2
|
Evidence for the cardiodepressive effects of the plasticizer di-2-ethylhexylphthalate (DEHP). BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.05.22.541729. [PMID: 37293060 PMCID: PMC10245927 DOI: 10.1101/2023.05.22.541729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Di-2-ethylhexylphthalate (DEHP) is commonly used in the manufacturing of plastic materials, including intravenous bags, blood storage bags, and medical-grade tubing. DEHP can leach from plastic medical products, which can result in inadvertent patient exposure. DEHP concentrations were measured in red blood cell (RBC) units stored between 7-42 days (23-119 μg/mL). Using these concentrations as a guide, Langendorff-perfused rat heart preparations were acutely exposed to DEHP. Sinus activity remained stable with lower doses of DEHP (25-50 μg/mL), but sinus rate declined by 43% and sinus node recovery time prolonged by 56.5% following 30-minute exposure to 100 μg/ml DEHP. DEHP exposure also exerted a negative dromotropic response, as indicated by a 69.4% longer PR interval, 108.5% longer Wenckebach cycle length, and increased incidence of atrioventricular uncoupling. Pretreatment with doxycycline partially rescued the effects of DEHP on sinus activity, but did not ameliorate the effects on atrioventricular conduction. DEHP exposure also prolonged the ventricular action potential and effective refractory period, but had no measurable effect on intracellular calcium transient duration. Follow-up studies using hiPSC-CM confirmed that DEHP slows electrical conduction in a time (15 min - 3 hours) and dose-dependent manner (10-100 μg/mL). Previous studies have suggested that phthalate toxicity is specifically attributed to metabolites of DEHP, including mono-2-ethylhexyl phthalate (MEHP). This study demonstrates that DEHP exposure also contributes to cardiac dysfunction in a dose- and time-dependent manner. Future work is warranted to investigate the impact of DEHP (and its metabolites) on human health, with special consideration for clinical procedures that employ plastic materials.
Collapse
|
3
|
KairoSight-3.0: A validated optical mapping software to characterize cardiac electrophysiology, excitation-contraction coupling, and alternans. JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY PLUS 2023; 5:100043. [PMID: 37786807 PMCID: PMC10544851 DOI: 10.1016/j.jmccpl.2023.100043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
Background Cardiac optical mapping is an imaging technique that measures fluorescent signals across a cardiac preparation. Dual optical imaging of voltage-sensitive and calcium-sensitive probes allows for simultaneous recordings of cardiac action potentials and intracellular calcium transients with high spatiotemporal resolution. The analysis of these complex optical datasets is both time intensive and technically challenging; as such, we have developed a software package for semi-automated image processing and analysis. Herein, we report an updated version of our software package (KairoSight-3.0) with features to enhance the characterization of cardiac parameters using optical signals. Methods To test software validity and applicability, we used Langendorff-perfused heart preparations to record transmembrane voltage and intracellular calcium signals from the epicardial surface. Isolated hearts from guinea pigs and rats were loaded with a potentiometric dye (RH237) and/or calcium indicator dye (Rhod-2AM) and fluorescent signals were acquired. We used Python 3.8.5 programming language to develop the KairoSight-3.0 software. Cardiac maps were validated with a user-specified manual mapping approach. Results Manual maps of action potential duration (30 or 80 % repolarization), calcium transient duration (30 or 80 % reuptake), action potential and calcium transient alternans were constituted to validate the accuracy of software-generated maps. Manual and software maps had high accuracy, with >97 % of manual and software values falling within 10 ms of each other and >75 % within 5 ms for action potential duration and calcium transient duration measurements (n = 1000-2000 pixels). Further, our software package includes additional measurement tools to analyze signal-to-noise ratio, conduction velocity, action potential and calcium transient alternans, and action potential-calcium transient coupling time to produce physiologically meaningful optical maps. Conclusions KairoSight-3.0 has enhanced capabilities to perform measurements of cardiac electrophysiology, calcium handling, alternans, and the excitation-contraction coupling with satisfactory accuracy.
Collapse
|
4
|
KairoSight-3.0 : A Validated Optical Mapping Software to Characterize Cardiac Electrophysiology, Excitation-Contraction Coupling, and Alternans. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.05.01.538926. [PMID: 37205349 PMCID: PMC10187248 DOI: 10.1101/2023.05.01.538926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Background Cardiac optical mapping is an imaging technique that measures fluorescent signals across a cardiac preparation. Dual optical mapping of voltage-sensitive and calcium-sensitive probes allow for simultaneous recordings of cardiac action potentials and intracellular calcium transients with high spatiotemporal resolution. The analysis of these complex optical datasets is both time intensive and technically challenging; as such, we have developed a software package for semi-automated image processing and analysis. Herein, we report an updated version of our software package ( KairoSight-3 . 0 ) with features to enhance characterization of cardiac parameters using optical signals. Methods To test software validity and applicability, we used Langendorff-perfused heart preparations to record transmembrane voltage and intracellular calcium signals from the epicardial surface. Isolated hearts from guinea pigs and rats were loaded with a potentiometric dye (RH237) and/or calcium indicator dye (Rhod-2AM) and fluorescent signals were acquired. We used Python 3.8.5 programming language to develop the KairoSight-3 . 0 software. Cardiac maps were validated with a user-specified manual mapping approach. Results Manual maps of action potential duration (30 or 80% repolarization), calcium transient duration (30 or 80% reuptake), action potential and calcium transient alternans were constituted to validate the accuracy of software-generated maps. Manual and software maps had high accuracy, with >97% of manual and software values falling within 10 ms of each other and >75% within 5 ms for action potential duration and calcium transient duration measurements (n=1000-2000 pixels). Further, our software package includes additional cardiac metric measurement tools to analyze signal-to-noise ratio, conduction velocity, action potential and calcium transient alternans, and action potential-calcium transient coupling time to produce physiologically meaningful optical maps. Conclusions KairoSight-3 . 0 has enhanced capabilities to perform measurements of cardiac electrophysiology, calcium handling, and the excitation-contraction coupling with satisfactory accuracy. Graphical Abstract Demonstrating Experimental and Data Analysis Workflow Created with Biorender.com.
Collapse
|
5
|
An electrophysiological substrate of COVID-19. J Electrocardiol 2023; 79:61-65. [PMID: 36963283 PMCID: PMC10027233 DOI: 10.1016/j.jelectrocard.2023.03.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 02/28/2023] [Accepted: 03/11/2023] [Indexed: 03/24/2023]
Abstract
SARS-CoV-2 infection is associated with an increased risk of late cardiovascular (CV) outcomes. However, more data is needed to describe the electrophysiologic (EP) manifestation of post-acute CV sequelae of COVID-19. We compared two cohorts of adult patients with SARS-CoV-2 polymerase chain reaction (PCR) test and an electrocardiogram (ECG) performed between March 1, 2020, and September 13, 2020, in a retrospective double-cohort study, "Cardiovascular Risk Stratification in Covid-19" (CaVaR-Co19; NCT04555187). Patients with positive PCR comprised a COVID-19(+) cohort (n = 41; 61% women; 80% symptomatic), whereas patients with negative tests formed the COVID-19(-) cohort (n = 155; 56% women). In longitudinal analysis, comparing 3 ECGs recorded before, during, and on average 40 days after index COVID-19 episode, after adjustment for demographic and socioeconomic characteristics, baseline CV risk factors and comorbidities, use of prescription medications (including QT-prolonging drugs) before and during index COVID-19 episode, and the longitudinal changes in RR' intervals, heart rhythm, and ventricular conduction type, only in the COVID-19(+) cohort QTc increased by +30.2(95% confidence interval [CI] 0.1-60.3) ms and the spatial ventricular gradient (SVG) elevation increased by +13.5(95%CI 1.2-25.9)°. In contrast, much smaller, statistically nonsignificant changes were observed in the COVID-19(-) cohort. In conclusion, post-acute CV sequelae of SARS-CoV-2 infection manifested on ECG by QTc prolongation and rotation of the SVG vector upward.
Collapse
|
6
|
The effect of sex and age on ex vivo cardiac electrophysiology: insight from a guinea pig model. Am J Physiol Heart Circ Physiol 2023; 324:H141-H154. [PMID: 36487188 PMCID: PMC9829463 DOI: 10.1152/ajpheart.00497.2022] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Revised: 11/30/2022] [Accepted: 12/02/2022] [Indexed: 12/14/2022]
Abstract
Highlighting the importance of sex as a biological variable, we recently reported sex differences in guinea pig in vivo electrocardiogram (ECG) measurements. However, substantial inconsistencies exist in this animal model, with conflicting reports of sex-specific differences in cardiac electrophysiology observed in vivo and in vitro. Herein, we evaluated whether sexual dimorphism persists in ex vivo preparations, using an isolated intact heart preparation. Pseudo-ECG recordings were collected in conjunction with dual optical mapping of transmembrane voltage and intracellular calcium from Langendorff-perfused hearts. In contrast to our in vivo results, we did not observe sex-specific differences in ECG parameters collected from isolated hearts. Furthermore, we observed significant age-specific differences in action potential duration (APD) and Ca2+ transient duration (CaD) during both normal sinus rhythm (NSR) and in response to dynamic pacing but only a modest sex-specific difference in CaD30. Similarly, the alternans fluctuation coefficient, conduction velocity during sinus rhythm or in response to pacing, and electrophysiology parameters (atrioventricular nodal effective refractory period, Wenckebach cycle length) were comparable between males and females. Results of our study suggest that the observed sex-specific differences in in vivo ECG parameters from guinea pigs are diminished in ex vivo isolated heart preparations, although age-specific patterns are prevalent. To assess sex as a biological variable in cardiac electrophysiology, a comprehensive approach may be necessary using both in vitro measurements from cardiomyocyte or intact heart preparations with secondary follow-up in vivo studies.NEW & NOTEWORTHY We evaluated whether the guinea pig heart has intrinsic sex-specific differences in cardiac electrophysiology. Although we observed sex-specific differences in in vivo ECGs, these differences did not persist ex vivo. Using a whole heart model, we observed similar APD, CaD, conduction velocity, and alternans susceptibility in males and females. We conclude that sex-specific differences in guinea pig cardiac electrophysiology are likely influenced by the in vivo environment and less dependent on the intrinsic electrical properties of the heart.
Collapse
|
7
|
Abstract
We aimed to determine absolute and relative risks of either symptomatic or asymptomatic SARS-CoV-2 infection for late cardiovascular (CV) events and all-cause mortality. We conducted a retrospective double cohort study of patients with either symptomatic or asymptomatic SARS-CoV-2 infection (COVID-19+ cohort) and its documented absence (COVID-19- cohort). The study investigators drew a simple random sample of records from all patients under the Oregon Health & Science University Healthcare (n = 65,585), with available COVID-19 test results, performed March 1, 2020 to September 13, 2020. Exclusion criteria were age <18 years and no established Oregon Health & Science University care. The primary outcome was a composite of CV morbidity and mortality. All-cause mortality was the secondary outcome. The study population included 1,355 patients (mean age 48.7 ± 20.5 years; 770 women [57%], 977 White non-Hispanic [72%]; 1,072 ensured [79%]; 563 with CV disease history [42%]). During a median 6 months at risk, the primary composite outcome was observed in 38 of 319 patients who were COVID-19+ (12%) and 65 of 1,036 patients who were COVID-19- (6%). In the Cox regression, adjusted for demographics, health insurance, and reason for COVID-19 testing, SARS-CoV-2 infection was associated with the risk for primary composite outcome (hazard ratio 1.71, 95% confidence interval 1.06 to 2.78, p = 0.029). Inverse probability-weighted estimation, conditioned for 31 covariates, showed that for every patient who was COVID-19+, the average time to all-cause death was 65.5 days less than when all these patients were COVID-19-: average treatment effect on the treated -65.5 (95% confidence interval -125.4 to -5.61) days, p = 0.032. In conclusion, either symptomatic or asymptomatic SARS-CoV-2 infection is associated with an increased risk for late CV outcomes and has a causal effect on all-cause mortality in a late post-COVID-19 period.
Collapse
|
8
|
Demographic and Methodological Heterogeneity in Electrocardiogram Signals From Guinea Pigs. Front Physiol 2022; 13:925042. [PMID: 35721548 PMCID: PMC9202081 DOI: 10.3389/fphys.2022.925042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Accepted: 05/09/2022] [Indexed: 11/24/2022] Open
Abstract
Electrocardiograms (ECG) are universally used to measure the electrical activity of the heart; however, variations in recording techniques and/or subject demographics can affect ECG interpretation. In this study, we investigated variables that are likely to influence ECG metric measurements in cardiovascular research, including recording technique, use of anesthesia, and animal model characteristics. Awake limb lead ECG recordings were collected in vivo from adult guinea pigs using a platform ECG system, while recordings in anesthetized animals were performed using both a platform and needle ECG system. We report significant heterogeneities in ECG metric values that are attributed to methodological differences (e.g., ECG lead configuration, ECG recording platform, presence or absence of anesthesia) that persist even within the same cohort of animals. Further, we report that variability in animal demographics is preserved in vivo ECG recordings—with animal age serving as a significant contributor, while sex-specific influences were less pronounced. Methodological approaches and subject demographics should be fully considered when interpreting ECG values in animal models, comparing datasets between studies, or developing artificial intelligence algorithms that utilize an ECG database.
Collapse
|
9
|
Digitizing ECG image: A new method and open-source software code. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 221:106890. [PMID: 35598436 PMCID: PMC9286778 DOI: 10.1016/j.cmpb.2022.106890] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 05/07/2022] [Accepted: 05/12/2022] [Indexed: 06/03/2023]
Abstract
BACKGROUND AND OBJECTIVE We aimed to develop and validate an open-source code ECG-digitizing tool and assess agreements of ECG measurements across three types of median beats, comprised of digitally recorded simultaneous and asynchronous ECG leads and digitized asynchronous ECG leads. METHODS We used the data of clinical studies participants (n = 230; mean age 30±15 y; 25% female; 52% had the cardiovascular disease) with available both digitally recorded and printed on paper and then scanned ECGs, split into development (n = 150) and validation (n = 80) datasets. The agreement between ECG and VCG measurements on the digitally recorded time-coherent median beat, representative asynchronous digitized, and digitally recorded beats was assessed by Bland-Altman analysis. RESULTS The sample-per-sample comparison of digitally recorded and digitized signals showed a very high correlation (0.977), a small mean difference (9.3 µV), and root mean squared error (25.9 µV). Agreement between digitally recorded and digitized representative beat was high [area spatial ventricular gradient (SVG) elevation bias 2.5(95% limits of agreement [LOA] -7.9-13.0)°; precision 96.8%; inter-class correlation [ICC] 0.988; Lin's concordance coefficient ρc 0.97(95% confidence interval [CI] 0.95-0.98)]. Agreement between digitally recorded asynchronous and time-coherent median beats was moderate for area-based VCG metrics (spatial QRS-T angle bias 1.4(95%LOA -33.2-30.3)°; precision 94.8%; ICC 0.95; Lin's concordance coefficient ρc 0.90(95%CI 0.82-0.95)]. CONCLUSIONS We developed and validated an open-source software tool for paper-ECG digitization. Asynchronous ECG leads are the primary source of disagreement in measurements on digitally recorded and digitized ECGs.
Collapse
|
10
|
Reproducibility of global electrical heterogeneity measurements on 12-lead ECG: The Multi-Ethnic Study of Atherosclerosis. J Electrocardiol 2021; 69:96-104. [PMID: 34626835 PMCID: PMC8627471 DOI: 10.1016/j.jelectrocard.2021.09.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 09/19/2021] [Accepted: 09/22/2021] [Indexed: 12/18/2022]
Abstract
OBJECTIVE Vectorcardiographic (VCG) global electrical heterogeneity (GEH) metrics showed clinical usefulness. We aimed to assess the reproducibility of GEH metrics. METHODS GEH was measured on two 10-s 12‑lead ECGs recorded on the same day in 4316 participants of the Multi-Ethnic Study of Atherosclerosis (age 69.4 ± 9.4 y; 2317(54%) female, 1728 (40%) white, 1138(26%) African-American, 519(12%) Asian-American, 931(22%) Hispanic-American). GEH was measured on a median beat, comprised of the normal sinus (N), atrial fibrillation/flutter (S), and ventricular-paced (VP) beats. Spatial ventricular gradient's (SVG's) scalar was measured as sum absolute QRST integral (SAIQRST) and vector magnitude QT integral (VMQTi). RESULTS Two N ECGs with heart rate (HR) bias of -0.64 (95% limits of agreement [LOA] -5.68 to 5.21) showed spatial area QRS-T angle (aQRST) bias of -0.12 (95%LOA -14.8 to 14.5). Two S ECGs with HR bias of 0.20 (95%LOA -15.8 to 16.2) showed aQRST bias of 1.37 (95%LOA -33.2 to 35.9). Two VP ECGs with HR bias of 0.25 (95%LOA -3.0 to 3.5) showed aQRST bias of -1.03 (95%LOA -11.9 to 9.9). After excluding premature atrial or ventricular beat and two additional beats (before and after extrasystole), the number of cardiac beats included in a median beat did not affect the GEH reproducibility. Mean-centered log-transformed values of SAIQRST and VMQTi demonstrated perfect agreement (Bias 0; 95%LOA -0.092 to 0.092). CONCLUSION GEH measurements on N, S, and VP median beats are reproducible. SVG's scalar can be measured as either SAIQRST or VMQTi. SIGNIFICANCE Satisfactory reproducibility of GEH metrics supports their implementation.
Collapse
|
11
|
Electrophysiological ventricular substrate of stroke: a prospective cohort study in the Atherosclerosis Risk in Communities (ARIC) study. BMJ Open 2021; 11:e048542. [PMID: 34479935 PMCID: PMC8420653 DOI: 10.1136/bmjopen-2020-048542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Accepted: 08/16/2021] [Indexed: 11/06/2022] Open
Abstract
OBJECTIVES The goal of the study was to determine an association of cardiac ventricular substrate with thrombotic stroke (TS), cardioembolic stroke (ES) and intracerebral haemorrhage (ICH). DESIGN Prospective cohort study. SETTING The Atherosclerosis Risk in Communities (ARIC) study in 1987-1989 enrolled adults (45-64 years), selected as a probability sample from four US communities (Minneapolis, Minnesota; Washington, Maryland; Forsyth, North Carolina; Jackson, Mississippi). Visit 2 was in 1990-1992, visit 3 in 1993-1995, visit 4 in 1996-1998 and visit 5 in 2011-2013. PARTICIPANTS ARIC participants with analysable ECGs and no history of stroke were included (n=14 479; age 54±6 y; 55% female; 24% black). Ventricular substrate was characterised by cardiac memory, spatial QRS-T angle (QRS-Ta), sum absolute QRST integral (SAIQRST), spatial ventricular gradient magnitude (SVGmag), premature ventricular contractions (PVCs) and tachycardia-dependent intermittent bundle branch block (TD-IBBB) on 12-lead ECG at visits 1-5. OUTCOME Adjudicated TS included a first definite or probable thrombotic cerebral infarction, ES-a first definite or probable non-carotid cardioembolic brain infarction. Definite ICH was included if it was the only stroke event. RESULTS Over a median 24.5 years follow-up, there were 899 TS, 400 ES and 120 ICH events. Cox proportional hazard risk models were adjusted for demographics, cardiovascular disease, risk factors, atrial fibrillation, atrial substrate and left ventricular hypertrophy. After adjustment, PVCs (HR 1.72; 95% CI 1.02 to 2.92), QRS-Ta (HR 1.15; 95% CI 1.03 to 1.28), SAIQRST (HR 1.20; 95% CI 1.07 to 1.34) and time-updated SVGmag (HR 1.19; 95% CI 1.08 to 1.32) associated with ES. Similarly, PVCs (HR 1.53; 95% CI 1.03 to 2.26), QRS-Ta (HR 1.08; 95% CI 1.01 to 1.16), SAIQRST (HR 1.07; 95% CI 1.01 to 1.14) and time-updated SVGmag (HR 1.11; 95% CI 1.04 to 1.19) associated with TS. TD-IBBB (HR 3.28; 95% CI 1.03 to 10.46) and time-updated SVGmag (HR 1.23; 95% CI 1.03 to 1.47) were associated with ICH. CONCLUSIONS PVC burden (reflected by cardiac memory) is associated with ischaemic stroke. Transient cardiac memory (likely through TD-IBBB) precedes ICH.
Collapse
|
12
|
Adaptive Cardiac Resynchronization Therapy Effect on Electrical Dyssynchrony (aCRT-ELSYNC): A randomized controlled trial. Heart Rhythm O2 2021; 2:374-381. [PMID: 34430943 PMCID: PMC8369305 DOI: 10.1016/j.hroo.2021.06.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
Abstract
BACKGROUND Adaptive cardiac resynchronization therapy (aCRT) is known to have clinical benefits over conventional CRT, but the mechanisms are unclear. OBJECTIVE Compare effects of aCRT and conventional CRT on electrical dyssynchrony. METHODS A prospective, double-blind, 1:1 parallel-group assignment randomized controlled trial in patients receiving CRT for routine clinical indications. Participants underwent cardiac computed tomography and 128-electrode body surface mapping. The primary outcome was change in electrical dyssynchrony measured on the epicardial surface using noninvasive electrocardiographic imaging before and 6 months post-CRT. Ventricular electrical uncoupling (VEU) was calculated as the difference between the mean left ventricular (LV) and right ventricular (RV) activation times. An electrical dyssynchrony index (EDI) was computed as the standard deviation of local epicardial activation times. RESULTS We randomized 27 participants (aged 64 ± 12 years; 34% female; 53% ischemic cardiomyopathy; LV ejection fraction 28% ± 8%; QRS duration 155 ± 21 ms; typical left bundle branch block [LBBB] in 13%) to conventional CRT (n = 15) vs aCRT (n = 12). In atypical LBBB (n = 11; 41%) with S waves in V5-V6, conduction block occurred in the anterior RV, as opposed to the interventricular groove in strict LBBB. As compared to baseline, VEU reduced post-CRT in the aCRT (median reduction 18.9 [interquartile range 4.3-29.2 ms; P = .034]), but not in the conventional CRT (21.4 [-30.0 to 49.9 ms; P = .525]) group. There were no differences in the degree of change in VEU and EDI indices between treatment groups. CONCLUSION The effect of aCRT and conventional CRT on electrical dyssynchrony is largely similar, but only aCRT harmoniously reduced interventricular dyssynchrony by reducing RV uncoupling.
Collapse
|
13
|
Eligibility for subcutaneous implantable cardioverter-defibrillator in congenital heart disease. Heart Rhythm 2021; 17:860-869. [PMID: 32354451 DOI: 10.1016/j.hrthm.2020.01.016] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Accepted: 01/08/2020] [Indexed: 02/02/2023]
Abstract
BACKGROUND Adult congenital heart disease (ACHD) patients can benefit from a subcutaneous implantable cardioverter-defibrillator (S-ICD). OBJECTIVE The purpose of this study was to assess left- and right-sided S-ICD eligibility in ACHD patients, use machine learning to predict S-ICD eligibility in ACHD patients, and transform 12-lead electrocardiogram (ECG) to S-ICD 3-lead ECG, and vice versa. METHODS ACHD outpatients (n = 101; age 42 ± 14 years; 52% female; 85% white; left ventricular ejection fraction [LVEF] 56% ± 9%) were enrolled in a prospective study. Supine and standing 12-lead ECG were recorded simultaneously with a right- and left-sided S-ICD 3-lead ECG. Peak-to-peak QRS and T amplitudes; RR, PR, QT, QTc, and QRS intervals; Tmax, and R/Tmax (31 predictor variables) were tested. Model selection, training, and testing were performed using supine ECG datasets. Validation was performed using standing ECG datasets and an out-of-sample non-ACHD population (n = 68; age 54 ± 16 years; 54% female; 94% white; LVEF 61% ± 8%). RESULTS Forty percent of participants were ineligible for S-ICD. Tetralogy of Fallot patients passed right-sided screening (57%) more often than left-sided screening (21%; McNemar χ2P = .025). Female participants had greater odds of eligibility (adjusted odds ratio [OR] 5.9; 95% confidence interval [CI] 1.6-21.7; P = .008). Validation of the ridge models was satisfactory for standing left-sided (receiver operating characteristic area under the curve [ROC AUC] 0.687; 95% CI 0.582-0.791) and right-sided (ROC AUC 0.655; 95% CI 0.549-0.762) S-ICD eligibility prediction. Validation of transformation matrices showed satisfactory agreement (<0.1 mV difference). CONCLUSION Nearly half of the contemporary ACHD population is ineligible for S-ICD. The odds of S-ICD eligibility are greater for female than for male ACHD patients. Machine learning prediction of S-ICD eligibility can be used for screening of S-ICD candidates.
Collapse
|
14
|
To the editor: S-ICD eligibility in adult congenital heart disease. ESC Heart Fail 2021; 8:3440-3441. [PMID: 34036723 PMCID: PMC8318419 DOI: 10.1002/ehf2.13449] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 03/08/2021] [Accepted: 05/16/2021] [Indexed: 11/06/2022] Open
|
15
|
Detection and removal of pacing artifacts prior to automated analysis of 12-lead ECG. Comput Biol Med 2021; 133:104396. [PMID: 33872969 DOI: 10.1016/j.compbiomed.2021.104396] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 04/05/2021] [Accepted: 04/09/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND Pacing artifacts must be excluded from the analysis of paced ECG waveform. This study aimed to develop and validate an algorithm to identify and remove the pacing artifacts on ECG and vectorcardiogram (VCG). METHODS We developed a semi-automatic algorithm that identifies the onset and offset of a pacing artifact based on the VCG signal slope steepness and designed a graphical user interface that permits quality control and fine-tuning the constraining threshold values. We used 1054 ECGs from the retrospective, multicenter cohort study "Global Electrical Heterogeneity and Clinical Outcomes," including 3825 atrial and 10,031 ventricular pacing artifacts for the algorithm development and 22 ECGs including 108 atrial and 241 ventricular pacing artifacts for validation. Validation was performed per digital sample. We used the kappa-statistic of interrater agreement between manually labeled sample (ground-truth) and automated detection. RESULTS The constraining parameter values were for onset threshold 13.06 ± 6.21 μV/ms, offset threshold 34.77 ± 17.80 μV/ms, and maximum window size 27.23 ± 3.53 ms. The automated algorithm detected a digital sample belonging to pacing artifact with a sensitivity of 74.5% and specificity of 99.6% and classified correctly 98.8% of digital samples (ROC AUC 0.871; 95%CI 0.853-0.878). The kappa-statistic was 0.785, indicating substantial agreement. The agreement was on 98.81% digital samples, significantly (P < 0.00001) larger than the random agreement on 94.43% of digital samples. CONCLUSIONS The semi-automated algorithm can detect and remove ECG pacing artifacts with high accuracy and provide a user-friendly interface for quality control.
Collapse
|
16
|
Competing risks in patients with primary prevention implantable cardioverter-defibrillators: Global Electrical Heterogeneity and Clinical Outcomes study. Heart Rhythm 2021; 18:977-986. [PMID: 33684549 DOI: 10.1016/j.hrthm.2021.03.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 02/25/2021] [Accepted: 03/01/2021] [Indexed: 10/22/2022]
Abstract
BACKGROUND Global electrical heterogeneity (GEH) is associated with sudden cardiac death in the general population. Its utility in patients with systolic heart failure who are candidates for primary prevention (PP) implantable cardioverter-defibrillators (ICDs) is unclear. OBJECTIVE The purpose of this study was to investigate whether GEH is associated with sustained ventricular tachycardia/ventricular fibrillation leading to appropriate ICD therapies in patients with heart failure and PP ICDs. METHODS We conducted a multicenter retrospective cohort study. GEH was measured by spatial ventricular gradient (SVG) direction (azimuth and elevation) and magnitude, QRS-T angle, and sum absolute QRST integral on preimplant 12-lead electrocardiograms. Survival analysis using cause-specific hazard functions compared the strength of associations with 2 competing outcomes: sustained ventricular tachycardia/ventricular fibrillation leading to appropriate ICD therapies and all-cause death without appropriate ICD therapies. RESULTS We analyzed 2668 patients (mean age 63 ± 12 years; 624 (23%) female; 78% white; 43% nonischemic cardiomyopathy; left ventricular ejection fraction 28% ± 11% from 6 academic medical centers). After adjustment for demographic, clinical, device, and traditional electrocardiographic characteristics, SVG elevation (hazard ratio [HR] per 1SD 1.14; 95% confidence interval [CI] 1.04-1.25; P = .004), SVG azimuth (HR per 1SD 1.12; 95% CI 1.01-1.24; P = .039), SVG magnitude (HR per 1SD 0.75; 95% CI 0.66-0.85; P < .0001), and QRS-T angle (HR per 1SD 1.21; 95% CI 1.08-1.36; P = .001) were associated with appropriate ICD therapies. Sum absolute QRST integral had different associations in infarct-related cardiomyopathy (HR 1.29; 95% CI 1.04-1.60) and nonischemic cardiomyopathy (HR 0.78; 95% CI 0.62-0.96) (Pinteraction = .022). CONCLUSION In patients with PP ICDs, GEH is independently associated with appropriate ICD therapies. The SVG vector points in distinctly different directions in patients with 2 competing outcomes.
Collapse
|
17
|
Electrocardiogram machine learning for detection of cardiovascular disease in African Americans: the Jackson Heart Study. EUROPEAN HEART JOURNAL. DIGITAL HEALTH 2021; 2:137-151. [PMID: 34048510 PMCID: PMC8139412 DOI: 10.1093/ehjdh/ztab003] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 12/10/2020] [Accepted: 01/12/2021] [Indexed: 01/31/2023]
Abstract
AIMS Almost half of African American (AA) men and women have cardiovascular disease (CVD). Detection of prevalent CVD in community settings would facilitate secondary prevention of CVD. We sought to develop a tool for automated CVD detection. METHODS AND RESULTS Participants from the Jackson Heart Study (JHS) with analysable electrocardiograms (ECGs) (n=3679; age, 6212 years; 36% men) were included. Vectorcardiographic (VCG) metrics QRS, T, and spatial ventricular gradient vectors magnitude and direction, and traditional ECG metrics were measured on 12-lead ECG. Random forests, convolutional neural network (CNN), lasso, adaptive lasso, plugin lasso, elastic net, ridge, and logistic regression models were developed in 80% and validated in 20% samples. We compared models with demographic, clinical, and VCG input (43 predictors) and those after the addition of ECG metrics (695 predictors). Prevalent CVD was diagnosed in 411 out of 3679 participants (11.2%). Machine learning models detected CVD with the area under the receiver operator curve (ROC AUC) 0.690.74. There was no difference in CVD detection accuracy between models with VCG and VCG + ECG input. Models with VCG input were better calibrated than models with ECG input. Plugin-based lasso model consisting of only two predictors (age and peak QRS-T angle) detected CVD with AUC 0.687 [95% confidence interval (CI) 0.6250.749], which was similar (P=0.394) to the CNN (0.660; 95% CI 0.5970.722) and better (P<0.0001) than random forests (0.512; 95% CI 0.4930.530). CONCLUSIONS Simple model (age and QRS-T angle) can be used for prevalent CVD detection in limited-resources community settings, which opens an avenue for secondary prevention of CVD in underserved communities.
Collapse
|
18
|
Characteristics of Cardiac Memory in Patients with Implanted Cardioverter-defibrillators: The Cardiac Memory with Implantable Cardioverter-defibrillator (CAMI) Study. J Innov Card Rhythm Manag 2021; 12:4395-4408. [PMID: 33654571 PMCID: PMC7909362 DOI: 10.19102/icrm.2021.120204] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Accepted: 10/12/2020] [Indexed: 01/12/2023] Open
Abstract
This study sought to determine factors associated with cardiac memory (CM) in patients with implantable cardioverter-defibrillators (ICDs). Patients with structural heart disease [n = 20; mean age: 72.6 ± 11.6 years; 80% male; mean left ventricular ejection fraction (LVEF): 31.7 ± 7.6%; history of myocardial infarction in 75% and nonsustained ventricular tachycardia (NSVT) in 85%] and preserved atrioventricular conduction received dual-chamber ICDs for primary (80%) or secondary (20%) prevention. Standard 12-lead electrocardiograms were recorded in AAI and DDD modes before and after seven days of right ventricular (RV) pacing in DDD mode with a short atrioventricular delay. The direction (azimuth and elevation) and magnitude of spatial QRS, T, and spatial ventricular gradient vectors were measured before and after seven days of RV pacing. CM was quantified as the degree of alignment between QRSDDD-7 and TAAI-7 vectors (QRSDDD-7 –TAAI-7 angle). Circular statistics and mixed models with a random slope and intercept were adjusted for changes in cardiac activation, LVEF, known risk factors, and the use of medications known to affect CM occurring on days 1 through 7. The QRSDDD-7–TAAI-7 angle strongly correlated (circular r = −0.972; p < 0.0001) with a TAAI-7–TDDD-7 angle. In the mixed models, CM-T azimuth changes [+132° (95% confidence interval (CI): 80°–184°); p < 0.0001] were counteracted by the history of MI [−180° (95% CI: −320° to −40°); p = 0.011] and female sex [−162° (95% CI: −268° to −55°); p = 0.003]. A CM-T area increase [+15 (95% CI: 6–24) mV*ms; p < 0.0001] was amplified by NSVT history [+27 (95% CI: 4–46) mV*ms; p = 0.007]. These findings suggest that preexistent electrical remodeling affects CM in response to RV pacing, that CM exhibits saturation behavior, and that women reach CM saturation more easily than men.
Collapse
|
19
|
Sex differences in vectorcardiogram of African-Americans with and without cardiovascular disease: a cross-sectional study in the Jackson Heart Study cohort. BMJ Open 2021; 11:e042899. [PMID: 33518522 PMCID: PMC7852937 DOI: 10.1136/bmjopen-2020-042899] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 12/19/2020] [Accepted: 01/11/2021] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVES We hypothesised that (1) the prevalent cardiovascular disease (CVD) is associated with global electrical heterogeneity (GEH) after adjustment for demographic, anthropometric, socioeconomic and traditional cardiovascular risk factors, (2) there are sex differences in GEH and (3) sex modifies an association of prevalent CVD with GEH. DESIGN Cross-sectional, cohort study. SETTING Prospective African-American The Jackson Heart Study (JHS) with a nested family cohort in 2000-2004 enrolled residents of the Jackson, Mississippi metropolitan area. PARTICIPANTS Participants from the JHS with analysable ECGs recorded in 2009-2013 (n=3679; 62±12 y; 36% men; 863 family units). QRS, T and spatial ventricular gradient (SVG) vectors' magnitude and direction, spatial QRS-T angle and sum absolute QRST integral (SAI QRST) were measured. OUTCOME Prevalent CVD was defined as the history of (1) coronary heart disease defined as diagnosed/silent myocardial infarction, or (2) revascularisation procedure defined as prior coronary/peripheral arterial revascularisation, or (3) carotid angioplasty/carotid endarterectomy, or (4) stroke. RESULTS In adjusted mixed linear models, women had a smaller spatial QRS-T angle (-12.2 (95% CI -19.4 to -5.1)°; p=0.001) and SAI QRST (-29.8 (-39.3 to -20.3) mV*ms; p<0.0001) than men, but larger SVG azimuth (+16.2(10.5-21.9)°; p<0.0001), with a significant random effect between families (+20.8 (8.2-33.5)°; p=0.001). SAI QRST was larger in women with CVD as compared with CVD-free women or men (+15.1 (3.8-26.4) mV*ms; p=0.009). Men with CVD had a smaller T area (by 5.1 (95% CI 1.2 to 9.0) mV*ms) and T peak magnitude (by 44 (95%CI 16 to 71) µV) than CVD-free men. T vectors pointed more posteriorly in women as compared with men (peak T azimuth + 17.2(8.9-25.6)°; p<0.0001), with larger sex differences in T azimuth in some families by +26.3(7.4-45.3)°; p=0.006. CONCLUSIONS There are sex differences in the electrical signature of CVD in African-American men and women. There is a significant effect of unmeasured genetic and environmental factors on cardiac repolarisation.
Collapse
|
20
|
Does Sex Modify an Association of Electrophysiological Substrate with Sudden Cardiac Death? The Atherosclerosis Risk in Communities (ARIC) Study. CARDIOVASCULAR DIGITAL HEALTH JOURNAL 2020; 1:80-88. [PMID: 34308405 PMCID: PMC8301262 DOI: 10.1016/j.cvdhj.2020.08.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
Abstract
Background Sex is a well-recognized risk factor for sudden cardiac death (SCD). We hypothesized that sex modifies the association of electrophysiological (EP) substrate with SCD. Objective The purpose of this study was to determine whether there are sex differences in electrocardiographic (ECG) measures and whether sex modifies the association of ECG measures of EP substrate with SCD. Methods Participants from the Atherosclerosis Risk in Communities study with analyzable ECGs (n = 14,725; age 54.2 ± 5.8 years; 55% female; 74% white) were included. EP substrate was characterized by heart rate, QRS, QTc, Cornell voltage, spatial ventricular gradient (SVG), and sum absolute QRST integral (SAI QRST) ECG metrics. Two competing outcomes were adjudicated: SCD and non-SCD. Interaction of ECG metrics with sex was studied in Cox proportional hazards and Fine-Gray competing risk models. Model 1 was adjusted for prevalent cardiovascular disease (CVD) and risk factors. Time-updated model 2 was additionally adjusted for incident nonfatal CVD. Relative hazard ratio (RHR) and relative subhazard ratio with 95% confidence interval (CI) for SCD and non-SCD risk for women relative to men were calculated. Model 1 was adjusted for prevalent CVD and risk factors. Time-updated model 2 was additionally adjusted for incident nonfatal CVD. Results Over median follow-up of 24.4 years, there were 530 SCDs (incidence 1.72; 95% CI 1.58–1.88 per 1000 person-years). Women compared to men experienced a greater risk of SCD associated with Cornell voltage (RHR 1.18; 95% CI 1.06–1.32; P = .003), SAI QRST (RHR 1.16; 95% CI 1.04–1.30; P = .007), and SVG magnitude (RHR 1.24; 95% CI 1.05–1.45; P = .009), independently from incident CVD. Conclusion In women, the global EP substrate is associated with up to 24% greater risk of SCD than in men, suggesting differences in underlying mechanisms and the need for sex-specific SCD risk stratification.
Collapse
|
21
|
|
22
|
Mechanisms of Arrhythmogenicity in Hypertrophic Cardiomyopathy: Insight From Non-invasive Electrocardiographic Imaging. Front Physiol 2020; 11:344. [PMID: 32390862 PMCID: PMC7194131 DOI: 10.3389/fphys.2020.00344] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Accepted: 03/26/2020] [Indexed: 11/25/2022] Open
Abstract
Background Mechanisms of arrhythmogenicity in hypertrophic cardiomyopathy (HCM) are not well understood. Objective To characterize an electrophysiological substrate of HCM in comparison to ischemic cardiomyopathy (ICM), or healthy individuals. Methods We conducted a prospective case-control study. The study enrolled HCM patients at high risk for ventricular tachyarrhythmia (VT) [n = 10; age 61 ± 9 years; left ventricular ejection fraction (LVEF) 60 ± 9%], and three comparison groups: healthy individuals (n = 10; age 28 ± 6 years; LVEF > 70%), ICM patients with LV hypertrophy (LVH) and known VT (n = 10; age 64 ± 9 years; LVEF 31 ± 15%), and ICM patients with LVH and no known VT (n = 10; age 70 ± 7 years; LVEF 46 ± 16%). All participants underwent 12-lead ECG, cardiac CT or MRI, and 128-electrode body surface mapping (BioSemi ActiveTwo, Netherlands). Non-invasive voltage and activation maps were reconstructed using the open-source SCIRun (University of Utah) inverse problem-solving environment. Results In the epicardial basal anterior segment, HCM patients had the greatest ventricular activation dispersion [16.4 ± 5.5 vs. 13.1 ± 2.7 (ICM with VT) vs. 13.8 ± 4.3 (ICM no VT) vs. 8.1 ± 2.4 ms (Healthy); P = 0.0007], the largest unipolar voltage [1094 ± 211 vs. 934 ± 189 (ICM with VT) vs. 898 ± 358 (ICM no VT) vs. 842 ± 90 μV (Healthy); P = 0.023], and the greatest voltage dispersion [median (interquartile range) 215 (161–281) vs. 189 (143–208) (ICM with VT) vs. 158 (109–236) (ICM no VT) vs. 110 (106–168) μV (Healthy); P = 0.041]. Differences were also observed in other endo-and epicardial basal and apical segments. Conclusion HCM is characterized by a greater activation dispersion in basal segments, a larger voltage, and a larger voltage dispersion through LV. Clinical Trial Registration www.clinicaltrials.gov Unique identifier: NCT02806479.
Collapse
|
23
|
Bringing Critical Race Praxis Into the Study of Electrophysiological Substrate of Sudden Cardiac Death: The ARIC Study. J Am Heart Assoc 2020; 9:e015012. [PMID: 32013706 PMCID: PMC7033892 DOI: 10.1161/jaha.119.015012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2019] [Accepted: 01/08/2020] [Indexed: 12/24/2022]
Abstract
Background Race is an established risk factor for sudden cardiac death (SCD). We sought to determine whether the association of electrophysiological substrate with SCD varies between black and white individuals. Methods and Results Participants from the ARIC (Atherosclerosis Risk in Communities) study with analyzable ECGs (n=14 408; age, 54±6 years; 74% white) were included. Electrophysiological substrate was characterized by ECG metrics. Two competing outcomes were adjudicated: SCD and non-SCD. Interaction of ECG metrics with race was studied in Cox proportional hazards and Fine-Gray competing risk models, adjusted for prevalent cardiovascular disease, risk factors, and incident nonfatal cardiovascular disease. At the baseline visit, adjusted for age, sex, and study center, blacks had larger spatial ventricular gradient magnitude (0.30 mV; 95% CI, 0.25-0.34 mV), sum absolute QRST integral (18.4 mV*ms; 95% CI, 13.7-23.0 mV*ms), and Cornell voltage (0.30 mV; 95% CI, 0.25-0.35 mV) than whites. Over a median follow-up of 24.4 years, SCD incidence was higher in blacks (2.86 per 1000 person-years; 95% CI, 2.50-3.28 per 1000 person-years) than whites (1.37 per 1000 person-years; 95% CI, 1.22-1.53 per 1000 person-years). Blacks with hypertension had the highest rate of SCD: 4.26 (95% CI, 3.66-4.96) per 1000 person-years. Race did not modify an association of ECG variables with SCD, except QRS-T angle. Spatial QRS-T angle was associated with SCD in whites (hazard ratio, 1.38; 95% CI, 1.25-1.53) and hypertension-free blacks (hazard ratio, 1.52; 95% CI, 1.09-2.12), but not in blacks with hypertension (hazard ratio, 1.15; 95% CI, 0.99-1.32) (P-interaction=0.004). Conclusions Race did not modify associations of electrophysiological substrate with SCD and non-SCD. Electrophysiological substrate does not explain racial disparities in SCD rate.
Collapse
|
24
|
Inward Rectifier Potassium Channels (Kir2.x) and Caveolin-3 Domain-Specific Interaction: Implications for Purkinje Cell-Dependent Ventricular Arrhythmias. Circ Arrhythm Electrophysiol 2019; 11:e005800. [PMID: 29326130 DOI: 10.1161/circep.117.005800] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2017] [Accepted: 11/30/2017] [Indexed: 01/05/2023]
Abstract
BACKGROUND In human cardiac ventricle, IK1 is mainly comprised Kir2.1, but Kir2.2 and Kir2.3 heterotetramers occur and modulate IK1. Long-QT syndrome-9-associated CAV3 mutations cause decreased Kir2.1 current density, but Kir2.x heterotetramers have not been studied. Here, we determine the effect of long-QT syndrome-9-CAV3 mutation F97C on Kir2.x homo- and heterotetramers and model-associated arrhythmia mechanisms. METHODS AND RESULTS Super-resolution microscopy, co-immunoprecipitation, cellular electrophysiology, on-cell Western blotting, and simulation of Purkinje and ventricular myocyte mathematical models were used. Kir2.x isoforms have unique subcellular colocalization in human cardiomyocytes and coimmunoprecipitate with Cav3. F97C-Cav3 decreased peak inward Kir2.2 current density by 50% (-120 mV; P=0.019) and peak outward by 75% (-40 mV; P<0.05) but did not affect Kir2.3 current density. FRET (Förster resonance energy transfer) efficiency for Kir2.2 with Cav3 is high, and on-cell Western blotting demonstrates decreased Kir2.2 membrane expression with F97C-Cav3. Cav3-F97C reduced peak inward and outward current density of Kir2.2/Kir2.1 or Kir2.2/Kir2.3 heterotetramers (P<0.05). Only Cav3 scaffolding and membrane domains co-immunoprecipitation with Kir2.1 and Kir2.2 and Kir2.x-N-terminal Cav3 binding motifs are required for interaction. Mathematical Purkinje, but not ventricular, myocyte model incorporating simulated current reductions, predicts spontaneous delayed after-depolarization-mediated triggered activity. CONCLUSIONS Kir2.x isoforms have a unique intracellular pattern of distribution in association with specific Cav3 domains and that critically depends on interaction with N-terminal Kir2.x Cav3-binding motifs. Long-QT syndrome-9-CAV3 mutation differentially regulates current density and cell surface expression of Kir2.x homomeric and heteromeric channels. Mathematical Purkinje cell model incorporating experimental findings suggests delayed after-depolarization-type triggered activity as a possible arrhythmia mechanism.
Collapse
|
25
|
Cardiac expression of ryanodine receptor subtype 3; a strategic component in the intracellular Ca 2+ release system of Purkinje fibers in large mammalian heart. J Mol Cell Cardiol 2017; 104:31-42. [PMID: 28111173 DOI: 10.1016/j.yjmcc.2017.01.011] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Revised: 12/08/2016] [Accepted: 01/18/2017] [Indexed: 10/20/2022]
Abstract
BACKGROUND Three distinct Ca2+ release channels were identified in dog P-cells: the ryanodine receptor subtype 2 (RyR2) was detected throughout the cell, while the ryanodine receptor subtype 3 (RyR3) and inositol phosphate sensitive Ca2+ release channel (InsP3R) were found in the cell periphery. How each of these channels contributes to the Ca2+ cycling of P-cells is unclear. Recent modeling of Ca2+ mobilization in P-cells suggested that Ca2+ sensitivity of Ca2+induced Ca2+release (CICR) was larger at the P-cell periphery. Our study examined whether this numerically predicted region of Ca2+ release exists in live P-cells. We compared the regional Ca2+ dynamics with the arrangement of intracellular Ca2+ release (CR) channels. METHODS Gene expression of CR channels was measured by qPCR in Purkinje fibers and myocardium of adult Yucatan pig hearts. We characterized the CR channels protein expression in isolated P-cells by immuno-fluorescence, laser scanning confocal microscopy, and 3D reconstruction. The spontaneous Ca2+ activity and electrically-evoked Ca2+ mobilization were imaged by 2D spinning disk confocal microscopy. Functional regions of P-cell were differentiated by the characteristics of local Ca2+ events. We used the Ca2+ propagation velocities as indicators of channel Ca2+ sensitivity. RESULTS RyR2 gene expression was identical in Purkinje fibers and myocardium (6 hearts) while RyR3 and InsP3R gene expressions were, respectively, 100 and 16 times larger in the Purkinje fibers. Specific fluorescent immuno-staining of Ca2+ release channels revealed an intermediate layer of RyR3 expression between a near-membrane InsP3R-region and a central RyR2-region. We found that cell periphery produced two distinct forms of spontaneous Ca2+-transients: (1) large asymmetrical Ca2+ sparks under the membrane, and (2) typical Ca2+-wavelets propagating exclusively around the core of the cell. Larger cell-wide Ca2+ waves (CWWs) appeared occasionally traveling in the longitudinal direction through the core of Pcells. Large sparks arose in a micrometric space overlapping the InsP3R expression. The InsP3R antagonists 2-aminoethoxydiphenyl borate (2-APB; 3μM) and xestospongin C (XeC; 50μM) dramatically reduced their frequency. The Ca2+ wavelets propagated in a 5-10μm thick layered space which matched the intermediate zone of RyR3 expression. The wavelet incidence was unchanged by 2-APB or XeC, but was reduced by 60% in presence of the RyR3 antagonist dantrolene (10μM). The velocity of wavelets was two times larger (86±16μm/s; n=14) compared to CWWs' (46±10μm/s; n=11; P<0.05). Electric stimulation triggered a uniform and large elevation of Ca2+ concentration under the membrane which preceded the propagation of Ca2+ into the interior of the cell. Elevated Cai propagated at 150μm/s (147±34μm/s; n=5) through the region equivalent to the zone of RyR3 expression. This velocity dropped by 50% (75±24μm/s; n=5) in the central region wherein predominant RyR2 expression was detected. CONCLUSION We identified two layers of distinct Ca2+ release channels in the periphery of Pcell: an outer layer of InsP3Rs under the membrane and an inner layer of RyR3s. The propagation of Ca2+ events in these layers revealed that Ca2+ sensitivity of Ca2+ release was larger in the RyR3 layer compared to that of other sub-cellular regions. We propose that RyR3 expression in P-cells plays a role in the stability of electric function of Purkinje fibers.
Collapse
|
26
|
Evoked centripetal Ca(2+) mobilization in cardiac Purkinje cells: insight from a model of three Ca(2+) release regions. J Physiol 2013; 591:4301-19. [PMID: 23897231 DOI: 10.1113/jphysiol.2013.253583] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Despite strong suspicion that abnormal Ca(2+) handling in Purkinje cells (P-cells) is implicated in life-threatening forms of ventricular tachycardias, the mechanism underlying the Ca(2+) cycling of these cells under normal conditions is still unclear. There is mounting evidence that P-cells have a unique Ca(2+) handling system. Notably complex spontaneous Ca(2+) activity was previously recorded in canine P-cells and was explained by a mechanistic hypothesis involving a triple layered system of Ca(2+) release channels. Here we examined the validity of this hypothesis for the electrically evoked Ca(2+) transient which was shown, in the dog and rabbit, to occur progressively from the periphery to the interior of the cell. To do so, the hypothesis was incorporated in a model of intracellular Ca(2+) dynamics which was then used to reproduce numerically the Ca(2+) activity of P-cells under stimulated conditions. The modelling was thus performed through a 2D computational array that encompassed three distinct Ca(2+) release nodes arranged, respectively, into three consecutive adjacent regions. A system of partial differential equations (PDEs) expressed numerically the principal cellular functions that modulate the local cytosolic Ca(2+) concentration (Cai). The apparent node-to-node progression of elevated Cai was obtained by combining Ca(2+) diffusion and 'Ca(2+)-induced Ca(2+) release'. To provide the modelling with a reliable experimental reference, we first re-examined the Ca(2+) mobilization in swine stimulated P-cells by 2D confocal microscopy. As reported earlier for the dog and rabbit, a centripetal Ca(2+) transient was readily visible in 22 stimulated P-cells from six adult Yucatan swine hearts (pacing rate: 0.1 Hz; pulse duration: 25 ms, pulse amplitude: 10% above threshold; 1 mm Ca(2+); 35°C; pH 7.3). An accurate replication of the observed centripetal Ca(2+) propagation was generated by the model for four representative cell examples and confirmed by statistical comparisons of simulations against cell data. Selective inactivation of Ca(2+) release regions of the computational array showed that an intermediate layer of Ca(2+) release nodes with an ~30-40% lower Ca(2+) activation threshold was required to reproduce the phenomenon. Our computational analysis was therefore fully consistent with the activation of a triple layered system of Ca(2+) release channels as a mechanism of centripetal Ca(2+) signalling in P-cells. Moreover, the model clearly indicated that the intermediate Ca(2+) release layer with increased sensitivity for Ca(2+) plays an important role in the specific intracellular Ca(2+) mobilization of Purkinje fibres and could therefore be a relevant determinant of cardiac conduction.
Collapse
|
27
|
Computational Evidence of Centripetal Propagating “Ca2+-Induced-Ca2+-Release” in Stimulated Cardiac Purkinje Cells. Biophys J 2013. [DOI: 10.1016/j.bpj.2012.11.2438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
28
|
An Integrated Gating Function of Cardiac Ca2+ Release Flux from a Cluster of SR-Ca2+ Channels. Biophys J 2013. [DOI: 10.1016/j.bpj.2012.11.2437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
|
29
|
Evoked Centripetal Ca2+ Activation in Cardiac Purkinje Cells: CICR or Ca2+ Diffusion? Biophys J 2011. [DOI: 10.1016/j.bpj.2010.12.3225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|