1
|
Comparison of cell casted and 3D-printed plastic scintillators for dosimetry applications. RADIATION PROTECTION DOSIMETRY 2023; 199:1824-1828. [PMID: 37819323 DOI: 10.1093/rpd/ncac248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 09/13/2022] [Accepted: 10/27/2022] [Indexed: 10/13/2023]
Abstract
Currently, the most used methods of plastic scintillator (PS) manufacturing are cell casting and bulk polymerisation, extrusion, injection molding, whereas digital light processing (DLP) 3D printing technique has been recently introduced. For our research, we measured blue-emitting EJ-200, EJ-208, green-emitting EJ-260, EJ-262 cell cast and two types of blue-emitting DLP-printed PSs. The light output of the samples, with the same dimension of 10 mm × 10 mm × 10 mm, was compared. The light output of the samples, relative to the reference EJ-200 cell-cast scintillator, equals about 40-49 and 70-73% for two types of 3D-printed, and two green-emitting cell-casted PSs, respectively. Performance of the investigated scintillators is sufficient to use them in a plastic scintillation dosemeter operating in high fluence gamma radiation fields.
Collapse
|
2
|
A new detector concept based on the prompt gamma radiation analysis for In vivo boron monitoring in BNCT. RADIATION PROTECTION DOSIMETRY 2023; 199:1932-1936. [PMID: 37819324 PMCID: PMC10566437 DOI: 10.1093/rpd/ncac245] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Revised: 09/18/2022] [Accepted: 10/26/2022] [Indexed: 10/13/2023]
Abstract
The problem of boron concentration monitoring during the boron neutron capture therapy (BNCT) therapy is one of the main challenges of this type of radiotherapy and is directly related to the nature of the interaction of neutrons with mater. Among the available in vivo methods of boron monitoring positron emission tomography seems to be very promising but it requires a new boron carrier with a β+ emitter, which is not yet clinically available. An alternative solution may be the prompt gamma radiation analysis (PGRA) based on the secondary radiation emitted in the interaction of neutrons with the patient's tissues. This method requires, however, compact gamma radiation detection systems sustaining high counting rates and characterized by very good energy resolution. In this contribution, we present state-of-the-art solutions for monitoring in BNCT based on PGRA. Moreover, we describe a new concept of such a system based on position-sensitive scintillator detectors equipped with an anti-Compton shield and data analysis supported with modern artificial intelligence algorithms.
Collapse
|
3
|
TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2023. [DOI: 10.1109/trpms.2023.3243735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/11/2023]
|
4
|
Main Features of the SIDDHARTA-2 Apparatus for Kaonic Deuterium X-Ray Measurements. EPJ WEB OF CONFERENCES 2022. [DOI: 10.1051/epjconf/202226201016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
The low-energy, non-perturbative regime of QCD can be studied directly by X-ray spectroscopy of light kaonic atoms. The SIDDHARTA-2 experiment, located at the DAΦNE collider, aims to measure the 2p → 1s transition in kaonic deuterium for the first time to extract the antikaon-nucleon scattering lengths. This measurement is impeded, inter alia, by the low K−d X-ray yield. Hence, several updates have been implemented on the apparatus to increase the signal-to-background ratio, which are discussed in detail in this paper: a lightweight gas target cell, novel Silicon Drift Detectors for the X-ray detection with excellent performance, and a veto system for active background suppression. The experiment has undergone a first preparatory run during DAΦNE’s commissioning phase in 2021, concluding with a successful kaonic helium measurement.
Collapse
|
5
|
Trigger rejection factor in the first kaonic helium run with the complete SIDDHARTA-2 setup. EPJ WEB OF CONFERENCES 2022. [DOI: 10.1051/epjconf/202227000028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
The SIDDHARTA-2 experiment aims to perform the first measurement of the kaonic deuterium 2p → 1s x-ray transition energy. Such measurement, together with the measurement of kaonic hydrogen 2p → 1s x-ray energy transition performed by the SIDDHARTA experiment in 2011, allows the determination of kaon proton and kaon neutron scattering lengths and represents a fundamental input for the low energies QCD in the strangeness sector theory. The SIDDHARTA-2 experiment is presently installed at the DAΦNE electronpositron collider at the National Laboratories of Frascati, in Italy. In May 2022, the kaonic 4He x-ray transitions measurement was performed by the complete SIDDHARTA-2 setup, by using a gaseous target. The result of this measurement is presented in this paper, with a specific focus on the background rejection performed by the kaon trigger system.
Collapse
|
6
|
Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography. Nat Commun 2021; 12:5658. [PMID: 34580294 PMCID: PMC8476595 DOI: 10.1038/s41467-021-25905-9] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 09/06/2021] [Indexed: 11/16/2022] Open
Abstract
Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron–positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10−4, with an over threefold improvement on the previous measurement. CPT violation could manifest itself in annihilating positronium events, but searching for this effect would require to know the spin of the annihilating system. Here, the authors do this using a positron-emission tomography scanner, finding no violation with a statistical precision of 10−4.
Collapse
|
7
|
3D TOF-PET image reconstruction using total variation regularization. Phys Med 2020; 80:230-242. [DOI: 10.1016/j.ejmp.2020.10.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Revised: 10/09/2020] [Accepted: 10/14/2020] [Indexed: 12/31/2022] Open
|
8
|
Hit-Time and Hit-Position Reconstruction in Strips of Plastic Scintillators Using Multithreshold Readouts. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2020. [DOI: 10.1109/trpms.2020.2990621] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
9
|
Performance assessment of the 2 γpositronium imaging with the total-body PET scanners. EJNMMI Phys 2020; 7:44. [PMID: 32607664 PMCID: PMC7326848 DOI: 10.1186/s40658-020-00307-w] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Accepted: 05/17/2020] [Indexed: 02/01/2023] Open
Abstract
Purpose In living organisms, the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511 keV photons. In this article, we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image based on annihilations into two photons. The main objectives of this work include the (i) estimation of the sensitivity of the total-body PET scanners for the ortho-positronium mean lifetime imaging using 2γ annihilations and (ii) estimation of the spatial and time resolution of the ortho-positronium image as a function of the coincidence resolving time (CRT) of the scanner. Methods Simulations are conducted assuming that radiopharmaceutical is labeled with 44Sc isotope emitting one positron and one prompt gamma. The image is reconstructed on the basis of triple coincidence events. The ortho-positronium lifetime spectrum is determined for each voxel of the image. Calculations were performed for cases of total-body detectors build of (i) LYSO scintillators as used in the EXPLORER PET and (ii) plastic scintillators as anticipated for the cost-effective total-body J-PET scanner. To assess the spatial and time resolution, the four cases were considered assuming that CRT is equal to 500 ps, 140 ps, 50 ps, and 10 ps. Results The estimated total-body PET sensitivity for the registration and selection of image forming triple coincidences (2γ+γprompt) is larger by a factor of 13.5 (for LYSO PET) and by factor of 5.2 (for plastic PET) with respect to the sensitivity for the standard 2γ imaging by LYSO PET scanners with AFOV = 20 cm. The spatial resolution of the ortho-positronium image is comparable with the resolution achievable when using TOF-FBP algorithms already for CRT = 50 ps. For the 20-min scan, the resolution better than 20 ps is expected for the mean ortho-positronium lifetime image determination. Conclusions Ortho-positronium mean lifetime imaging based on the annihilations into two photons and prompt gamma is shown to be feasible with the advent of the high sensitivity total-body PET systems and time resolution of the order of tens of picoseconds.
Collapse
|
10
|
Abstract
A detection system of the conventional PET tomograph is set-up to record data from [Formula: see text] annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibility of positronium mean lifetime imaging with the J-PET tomograph constructed from plastic scintillators. For this purposes simulations of the ortho-positronium formation and its annihilation into three photons were performed taking into account distributions of photons' momenta as predicted by the theory of quantum electrodynamics and the response of the J-PET tomograph. In order to test the proposed ortho-positronium lifetime image reconstruction method, we concentrate on the decay of the ortho-positronium into three photons and applications of radiopharmaceuticals labeled with isotopes emitting a prompt gamma. The proposed method of imaging is based on the determination of hit-times and hit-positions of registered photons which enables the reconstruction of the time and position of the annihilation point as well as the lifetime of the ortho-positronium on an event-by-event basis. We have simulated the production of the positronium in point-like sources and in a cylindrical phantom composed of a set of different materials in which the ortho-positronium lifetime varied from 2.0 ns to 3.0 ns, as expected for ortho-positronium created in the human body. The presented reconstruction method for total-body J-PET like detector allows to achieve a mean lifetime resolution of ∼40 ps. Recent positron annihilation lifetime spectroscopy measurements of cancerous and healthy uterine tissues show that this sensitivity may allow to study the morphological changes in cell structures.
Collapse
|
11
|
Λp correlated production from low energy K −12C interactions by AMADEUS. EPJ WEB OF CONFERENCES 2019. [DOI: 10.1051/epjconf/201919903010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
The main steps for the analysis of the Λp correlated production in low-energy K− captures on Carbon nuclei, performed by the AMADEUS collaboration, are presented. The goal is to perform the first comprehensive study of the K− absorption on two, three and four nucleons, exploiting the lowmomentum K−s (pK ~ 127 MeV/c) produced at the DAΦNE collider, and to measure the low-energy cross sections and branching ratios of the K− multinucleon absorption processes in both the Λp and Σ0p channels. An integrated luminosity of 1.74 fb−1 collected during the KLOE 2004/2005 data campaign is analysed by reconstructing the Λp final state.
Collapse
|
12
|
Abstract
The interaction of antikaons (K−) with nucleons and nuclei in the low-energy regime represents a very active research field in hadron physics. A unique and rather direct experimental access to the antikaon-nucleon scattering lengths is provided by precision X-ray spectroscopy of transitions in low-lying states in the lightest kaonic atoms (i.e. kaonic hydrogen and deuterium). In the SIDDHARTA experiment at the electron-positron collider DAFNE of LNFINFN we measured the most precise values of the strong interaction observables in conic hydrogen. The strong interaction on the 1s ground state of the electromagnetically bound K-p atom causes an energy shift and broadening of the 1s state. SIDDHARTA will extend the spectroscopy to kaonic deuterium to get access to the antikaon-neutron interaction and thus the isospin dependent scattering lengths. At J-PARC a kaon beam is used in a complementary experiment with a different setup for spectroscopy of kaonic deuterium atoms. The talk will give an overview of the of the upcoming experiments SIDDHARTA and the complementary experiment at J-PARC.Furthermore, the implications of the experiments for the theory of low-energy strong interaction with strangeness will be discussed.
Collapse
|
13
|
Low Energy Antikaon-nucleon/nuclei interaction studies by AMADEUS. EPJ WEB OF CONFERENCES 2019. [DOI: 10.1051/epjconf/201919901014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
The AMADEUS experiment at the DAΦNE collider of LNF-INFN deals with the investigation of the at-rest, or low-momentum, K− interactions in light nuclear targets, with the aim to constrain the low energy QCD models in the strangeness sector. The 0 step of the experiment consisted in the reanalysis of the 2004/2005 KLOE data, exploiting K− absorptions in H, 4He, 9Be and 12C, leading to the first invariant mass spectroscopic study with very low momentum (about 100 MeV) in-flight K− captures. With AMADEUS step 1 a dedicated pure Carbon target was implemented in the central region of the KLOE detector, providing a high statistic sample of pure at-rest K− nuclear interaction. The first measurement of the non-resonant transition amplitude $\left| {{A_{{K^ - }n \to \Lambda {\pi ^ - }}}} \right|$ at $\sqrt s = 33\,MeV$ below the K̄N threshold is presented, in relation with the Λ(1405) properties studies. The analysis procedure adopted in the serarch for K− multi-nucleon absorption cross sections and Branching Ratios will be also described.
Collapse
|
14
|
Near threshold kaon-kaon interaction in the reactions ${e^ + }{e^ - } \to {K^ + }{K^ - }\gamma$ and ${e^ + }{e^ - } \to {K^0}{\bar K^0}\gamma$. EPJ WEB OF CONFERENCES 2019. [DOI: 10.1051/epjconf/201919903002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
15
|
Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS 2018; 78:970. [PMID: 30636927 PMCID: PMC6315056 DOI: 10.1140/epjc/s10052-018-6461-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2018] [Accepted: 11/14/2018] [Indexed: 05/25/2023]
Abstract
J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration of both primary and scattered photons enables to determinate the linear polarization of the primary photon on the event by event basis with a certain probability. Here we present quantitative results on the feasibility of such polarization measurements of photons from the decay of positronium with the J-PET and explore the physical limitations for the resolution of the polarization determination of 511 keV photons via Compton scattering. For scattering angles of about 82∘ (where the best contrast for polarization measurement is theoretically predicted) we find that the single event resolution for the determination of the polarization is about 40∘ (predominantly due to properties of the Compton effect). However, for samples larger than ten thousand events the J-PET is capable of determining relative average polarization of these photons with the precision of about few degrees. The obtained results open new perspectives for studies of various physics phenomena such as quantum entanglement and tests of discrete symmetries in decays of positronium and extend the energy range of polarization measurements by five orders of magnitude beyond the optical wavelength regime.
Collapse
|
16
|
Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA SoC Devices. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:2526-2535. [PMID: 29994248 DOI: 10.1109/tmi.2018.2837741] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian positron emission tomography scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead, we introduce a field programmable gate array system-on-chip platform connected directly to data streams coming from the scanner, which can perform event building, filtering, coincidence search, and region-of-response reconstruction by the programmable logic and visualization by the integrated processors. The platform significantly reduces data volume converting raw data to a list-mode representation, while generating visualization on the fly.
Collapse
|
17
|
Estimating the NEMA characteristics of the J-PET tomograph using the GATE package. ACTA ACUST UNITED AC 2018; 63:165008. [DOI: 10.1088/1361-6560/aad29b] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
18
|
Studies of low-energy K - nuclear interactions by AMADEUS. EPJ WEB OF CONFERENCES 2018. [DOI: 10.1051/epjconf/201818202035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
The goal of the AMADEUS experiment is to shed light on unsolved fundamental issues in the non-perturbative strangeness QCD sector through the study of lowenergy K- hadronic interactions with light nuclear targets. The main open questions are the controversial nature of the Δ(1405) state, which is investigated in hyperon-pion correlation studies, and the possible existence of exotic antikaon multi-nucleon clusters, whose search in K- induced reactions is intimately related to the studies of the K- multi-nucleon absorption processes in hyperon-nucleon/nucleus channels. The DAΦNE collider at the INFN-LNF provides unique monochromatic low-momentum kaons from the φ meson decay almost at-rest, suitable for the AMADEUS studies. The KLOE detector is exploited as an active target, in order to obtain excellent acceptance and resolution data for K- nuclear capture on H, 4He, 9Be and 12C, both at-rest and in-flight.
Collapse
|
19
|
Low energy interaction studies of negative kaons in light nuclear targets by AMADEUS. EPJ WEB OF CONFERENCES 2018. [DOI: 10.1051/epjconf/201818101005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
The AMADEUS collaboration is performing experimental investigations in the sector of the low energy strangeness hadron physics by taking advantage of the DAΦNE collider, which provides a unique source of monochromatic low-momentum kaons and exploiting the KLOE detector as an active target. The K− single and multi-nuclear absorption on H, 4He, 9Be and 12C, both at-rest and in-flight, are studied with the aim to determine the nature of the controversial Λ(1405), the non-resonant hyperon pion formation amplitude below the K̅N threshold, the yield and cross sections of K− multi-nucleon absorptions intimately connected to the antikaon multi-nucleon clusters properties and the K− scattering cross sections on light nuclear targets.
These studies have a strong impact on the non-perturbative strangeness QCD with implications ranging from nuclear physics to the equation of state of neutron stars.
Collapse
|
20
|
Abstract
The interaction of antikaons with nucleons and nuclei in the low-energy regime represents an active research field in hadron physics with still many important open questions. The investigation of light kaonic atoms, in which one electron is replaced by a negatively charged kaon, is a unique tool to provide precise information on this interaction; the energy shift and the broadening of the low-lying states of such atoms, induced by the kaon-nucleus hadronic interaction, can be determined with high precision from the atomic X-ray spectroscopy, and this experimental method provides unique information to understand the low energy kaon-nucleus interaction at the production threshold. The lightest atomic systems, like the kaonic hydrogen and the kaonic deuterium deliver, in a model-independent way, the isospin-dependent kaon-nucleon scattering lengths. The most precise kaonic hydrogen measurement to-date, together with an exploratory measurement of kaonic deuterium, were carried out in 2009 by the SIDDHARTA collaboration at the DAΦNE electron-positron collider of LNF-INFN, combining the excellent quality kaon beam delivered by the collider with new experimental techniques, as fast and very precise X-ray detectors, like the Silicon Drift Detectors. The SIDDHARTA results triggered new theoretical work, which achieved major progress in the understanding of the low-energy strong interaction with strangeness reflected by the antikaon-nucleon scattering lengths calculated with the antikaon-proton amplitudes constrained by the SIDDHARTA data. The most important open question is the experimental determination of the hadronic energy shift and width of kaonic deuterium; presently, a major upgrade of the setup, SIDDHARTA-2, is being realized to reach this goal. In this paper, the results obtained in 2009 and the proposed SIDDHARTA-2 upgrades are presented.
Collapse
|
21
|
Calculation of the time resolution of the J-PET tomograph using kernel density estimation. Phys Med Biol 2017; 62:5076-5097. [DOI: 10.1088/1361-6560/aa7005] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
22
|
Experimental results on multi-nucleonic K −absorptions in light nuclei. EPJ WEB OF CONFERENCES 2017. [DOI: 10.1051/epjconf/201713709010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
23
|
|
24
|
Hybrid TOF-PET/MRI local transceiver coil. Phys Med 2016. [DOI: 10.1016/j.ejmp.2016.07.479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
|
25
|
Novel J-PET scanner combined with positron annihilation lifetime spectroscopy technique as a tool for morphometric imaging. Phys Med 2016. [DOI: 10.1016/j.ejmp.2016.07.478] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
|
26
|
Mobile PET insert for simultaneous PET/MRI imaging. Phys Med 2016. [DOI: 10.1016/j.ejmp.2016.07.477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
|
27
|
Novel plastic scinitllators for the fully digital and MRI compatible J-PET scanner. Phys Med 2016. [DOI: 10.1016/j.ejmp.2016.07.480] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
28
|
Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph. Phys Med Biol 2016; 61:2025-47. [PMID: 26895187 DOI: 10.1088/0031-9155/61/5/2025] [Citation(s) in RCA: 73] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it can still be improved since, as it is shown in this article, the intrinsic limit of time resolution for the determination of time of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much lower. As the major point of the article, a method allowing to record timestamps of several photons, at two ends of the scintillator strip, by means of matrix of silicon photomultipliers (SiPM) is introduced. As a result of simulations, conducted with the number of SiPM varying from 4 to 42, it is shown that the improvement of timing resolution saturates with the growing number of photomultipliers, and that the [Formula: see text] configuration at two ends allowing to read twenty timestamps, constitutes an optimal solution. The conducted simulations accounted for the emission time distribution, photon transport and absorption inside the scintillator, as well as quantum efficiency and transit time spread of photosensors, and were checked based on the experimental results. Application of the [Formula: see text] matrix of SiPM allows for achieving the coincidence resolving time in positron emission tomography of [Formula: see text]0.170 ns for 15 cm axial field-of-view (AFOV) and [Formula: see text]0.365 ns for 100 cm AFOV. The results open perspectives for construction of a cost-effective TOF-PET scanner with significantly better TOF resolution and larger AFOV with respect to the current TOF-PET modalities.
Collapse
|
29
|
Hybrid TOF-PET/MRI local transceiver coil. Radiother Oncol 2016. [DOI: 10.1016/s0167-8140(16)30097-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
30
|
|
31
|
Front-end electronics and hit position reconstruction methods for the J-PET scanner. Radiother Oncol 2016. [DOI: 10.1016/s0167-8140(16)30129-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
32
|
Studies of discrete symmetries in a purely leptonic system using the Jagiellonian Positron Emission Tomograph. EPJ WEB OF CONFERENCES 2016. [DOI: 10.1051/epjconf/201613007015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
33
|
J-PET detector system for studies of the electron-positron annihilations. EPJ WEB OF CONFERENCES 2016. [DOI: 10.1051/epjconf/201613007020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
34
|
A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS 2016; 76:445. [PMID: 27547122 PMCID: PMC4978780 DOI: 10.1140/epjc/s10052-016-4294-3] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2016] [Accepted: 08/01/2016] [Indexed: 05/13/2023]
Abstract
We present a study of the application of the Jagiellonian positron emission tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on organic scintillators in contrast to all current PET scanners based on inorganic crystals. Monte Carlo simulations show that the J-PET as an axially symmetric and high acceptance scanner can be used as a multi-purpose detector well suited to pursue research including e.g. tests of discrete symmetries in decays of ortho-positronium in addition to the medical imaging. The gamma quanta originating from o-Ps decay interact in the plastic scintillators predominantly via the Compton effect, making the direct measurement of their energy impossible. Nevertheless, it is shown in this paper that the J-PET scanner will enable studies of the [Formula: see text] decays with angular and energy resolution equal to [Formula: see text] and [Formula: see text], respectively. An order of magnitude shorter decay time of signals from plastic scintillators with respect to the inorganic crystals results not only in better timing properties crucial for the reduction of physical and instrumental background, but also suppresses significantly the pile-ups, thus enabling compensation of the lower efficiency of the plastic scintillators by performing measurements with higher positron source activities.
Collapse
|
35
|
Determination of the η(')-proton scattering length in free space. PHYSICAL REVIEW LETTERS 2014; 113:062004. [PMID: 25148320 DOI: 10.1103/physrevlett.113.062004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Indexed: 06/03/2023]
Abstract
Taking advantage of both the high mass resolution of the COSY-11 detector and the high energy resolution of the low-emittance proton beam of the cooler synchrotron COSY, we determine the excitation function for the pp→ppη(') reaction close to threshold. Combining these data with previous results, we extract the scattering length for the η(')-proton potential in free space to be Re(a(pη(')))=0±0.43 fm and Im(a(pη(')))=0.37(-0.16)(+0.40) fm.
Collapse
|
36
|
|
37
|
Close to threshold η′ meson production in proton-proton collisions at cosy-11. EPJ WEB OF CONFERENCES 2014. [DOI: 10.1051/epjconf/20148102003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
38
|
Search for the KS→ 3 π0decay with the KLOE detector. EPJ WEB OF CONFERENCES 2012. [DOI: 10.1051/epjconf/20123705004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
39
|
Determination of the total width of the η' meson. PHYSICAL REVIEW LETTERS 2010; 105:122001. [PMID: 20867630 DOI: 10.1103/physrevlett.105.122001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2010] [Indexed: 05/29/2023]
Abstract
Taking advantage of both the low-emittance proton beam of the cooler synchrotron COSY and the high momentum precision of the COSY-11 detector system, the mass distribution of the η' meson was measured with a resolution of 0.33 MeV/c2 (FWHM), improving the experimental mass resolution by almost an order of magnitude with respect to previous results. Based on the sample of more than 2300 reconstructed pp → ppη' events, the total width of the η' meson was determined to be Γ(η') = 0.226 ± 0.017(stat) ± 0.014(syst) MeV/c2.
Collapse
|