1
|
Impact of east Japan earthquake disaster with massive tsunami for prevalence of Takotsubo syndrome – a multicenter regional registry before and after east Japan earthquake disaster. Eur Heart J 2020. [DOI: 10.1093/ehjci/ehaa946.1813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Previous studies demonstrated Takotsubo syndrome (TS) was easy provoked by earthquake disaster. However, a previous other regional report demonstrated TS was not increased after 2011 east Japan earthquake disaster. The purpose of this study was to clarify incidence of TS after the earthquake disaster in Iwate prefecture during long term period.
Method
Consecutive hospitalized TS patients were registered during 8 years between 2009 and 2016 in our medical university and five Iwate prefecture hospitals. Moreover, patients were divided into two groups, i.e., those with the inland and those with tsunami-stricken area groups. Prevalence of TS were calculated by standard incidence ratio (SIR) before and after the earthquake disaster. Moreover, long-term prognosis in the both groups was compared using Kaplan-Meier analysis.
Results
A total of 112 TS (male 25 and female 87) were registered from acute coronary syndrome registry in each hospital (n=4,163). Averaged age was 75.3 year-old. A total number of TS just after the two months of the earthquake (March and April 2011) was nine and significance monthly variation was observed comparing with the other months (p=0.029). SIR before and after the disaster is as following Figure. There were no significant differences for long-term prognosis between the two groups (p=0.20).
Conclusion
Incidence of TS was increased in acute phase after east Japan earthquake disaster. However, significance increases were maintained during long-term period, although number of TS was decreased after acute phase. TS is increased not only acute but also chronic phase after the serious earthquake disaster.
Standard incidence ratio
Funding Acknowledgement
Type of funding source: None
Collapse
|
2
|
Diagnostic significance of all-night video-polysomnography in elderly-onset temporal lobe epilepsy. Sleep Med 2019. [DOI: 10.1016/j.sleep.2019.11.1210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
3
|
Neurophysiological mechanism of behavioral episodes in rapid eye movement sleep behavior disorder: a video-polysomnographic approach. Sleep Med 2019. [DOI: 10.1016/j.sleep.2019.11.1217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
4
|
A key-point based real-time tracking of lung tumor in x-ray image sequence by using difference of Gaussians filtering and optical flow. ACTA ACUST UNITED AC 2018; 63:185007. [DOI: 10.1088/1361-6560/aada71] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
5
|
P4393The clinical characteristics of mortality in patients with Takotsubo Syndrome during hospitalization-A Multicenter Registry in Eight-University Hospitals in East Japan. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy563.p4393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
6
|
P3794Plasma exchange regulates CD14+CD16+ activated monocytes and CD4+CD25+FOXP3+ regulatory T cells in Kawasaki disease. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy563.p3794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
7
|
DEVELOPMENT OF A HIGH-EFFICIENCY PROTON RECOIL TELESCOPE FOR D-T NEUTRON FLUENCE MEASUREMENT. RADIATION PROTECTION DOSIMETRY 2018; 180:417-421. [PMID: 29309663 DOI: 10.1093/rpd/ncx278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2017] [Indexed: 06/07/2023]
Abstract
A high-efficiency proton recoil telescope was developed to determine neutron fluences in neutron fields using the 3H(d,n)4He reaction. A 2-mm thick plastic scintillation detector was employed as a radiator to increase the detection efficiency and compensate for the energy loss of the recoil proton within. Two silicon detectors were employed as the ΔE and E detectors. The distance between the radiator and the E detector was varied between 50 and 150 mm. The telescope had detection efficiencies of 3.5 × 10-3 and 7.1 × 10-4 cm2 for distances of 50 and 100 mm, respectively, which were high enough to determine the neutron fluence in 14.8-MeV neutron fields, with a few thousand cm-2 s-1 fluence rate, within a few hours.
Collapse
|
8
|
P1859Functional and anatomical connectivity from the dorsomedial hypothalamus to the ventral medullary cardiovascular regions: possible neural substrate mediating stress-induced sympathoexcitation. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy565.p1859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
9
|
Abstract
To determine the effect of left ventricular assist device (LVAD) pumping on sympathetic tone, renal sympathetic nerve activity (RSNA) was detected in acute animal experiments. Our TH-7B pneumatically driven, sac-type ventricular assist device was used in 7 adult mongrel dogs. RSNA was detected by the use of bipolar electrodes attached to the left renal sympathetic nerve. RSNA was amplified and integrated by use of an R-C integrator circuit. The area of the integrated nerve discharge per unit time was calculated in the computer system and expressed as RSNA per unit time. During LVAD pumping, RSNA decreased with increase in blood pressure, with an increase in pulmonary artery flow, and with a decrease in left atrial pressure. These data suggest that LVAD has an effect on the sympathetic nervous system which is mediated by the aortic and cardiopulmonary baroreflex system.
Collapse
|
10
|
Estimation of the following Cardiac Output Using Sympathetic Tone and Hemodynamics for the Control of a Total Artificial Heart. Int J Artif Organs 2018. [DOI: 10.1177/039139889201501007] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A sympathetic neurogram is potentially useful for the development of a real time total artificial heart (TAH) control system. We used sympathetic tone and hemodynamic derivatives to estimate the following cardiac output in acute animal experiments using adult mongrel dogs. Moving averages of the mean left atrial pressure and mean aortic pressure were used as parameters of the preload and afterload, respectively. Renal sympathetic nerve activity (RSNA) was employed as a parameter of sympathetic tone. Equations for the following cardiac output were calculated using multiple linear regression analysis of the time series data. A significant correlation was observed between the estimated and following measured cardiac output. These results suggest the potential usefulness of the sympathetic neurogram for the real time TAH automatic control system.
Collapse
|
11
|
Abstract
For the Quality of life (QOL) of patients with an artificial heart system, monitoring an information of the cardiovascular control system may be important. We have been evaluating the autonomic nervous system for that purpose. Recently, fluctuations in hemodynamic parameters including heart rate variability (HRV) were evaluated by means of spectral analysis and nonlinear mathematical analysis. Respiratory wavers in HRV were thought ro reflect ongoing information of the parasympathetic nerve activity. Is it true? In order to confirm this hypothesis, we recorded vagal nerve activity directly in the chronic animal experiments. Six healthy adult goats were anesthetized with Halothene inhalation and thoracotomy were performed by the fourth lib resection during mechanical ventilation. Arterial blood pressure, right and left atrial pressures were continuously monitored with the catheter insertion. Cardiac output was measured by the electromagnetic flowmeter attached to the ascending aorta. After the chest was closed, incision was made to the left neck and left vagal nerve was separated. Stainless steel electrodes were inserted into the vagal nerve and fixed by the plasticizer. After the incision was closed, the goats were transferred to the cage and extubated after waking. Hemodynamic parameters and vagal nerve activity were measured in the awake condition. The results showed that clear observation of the autonomic nerve discharges were embodied by this experimental system. The vagal nerve discharges were synchronized with heart beat and respiration. The vagal nerve tonus was significantly influenced by the hemodynamic alteration. However in some condition, the respiratory wave was not always consistent with tonus of the vagal nerve activity, thus suggesting that we should check another information to evaluate the parasympathetic tone. We must continue this study to evaluate an autonomic nerve during artifical heart circulation.
Collapse
|
12
|
Abstract
To assess the effect of a total artificial heart (TAH) on the autonomic nervous system a power spectral analysis of the hemodynamics in a TAH animal was done by the maximum entropy method. Two pneumatically driven sac-type ventricular assist devices were implanted as total biventricular bypass (BVB) in adult mongrel dogs to compare the differences between natural heart and TAH. Once the BVB was pumping, the natural heart was electrically fibrillated to constitute the BVB-type TAH model. In the arterial pressure waveform in animals with TAH, respiratory waves were not changed (97.7±24.6%) though Mayer waves were significantly decreased (47.5 ± 22.6%) compared with the animal with a natural heart. These results suggest that prosthetic hemodynamics in the TAH animal affect fluctuations in the cardiovascular system.
Collapse
|
13
|
Monitoring System for the Totally Implantable Ventricular Assist System by Use of Sensors for Virtual Reality. Int J Artif Organs 2018. [DOI: 10.1177/039139889802100611] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
For the development of the totally implantable artificial organs, it is an important problem to monitor the conditions of the implantable devices, especially when used in clinical cases. In this study, we used position sensors for the 3-dimensional (3-D) virtual reality (VR) system monitor an implantable artificial heart. The sensors used in the experiments were 3-space Fastrak (Polhemus, USA). The position sensors using electro-magnetic forces were attached to the inner actuating zone. Sensitivity of the position sensors was in the order of around 0.8 mm. By use of these VR position sensors, we could easily detect the six degrees of freedom as x,y,z, and pitch, yaw, roll of these sensors. Experimental evaluation using a model circulation loop and healthy adult goats was performed. Experimental results suggest that our newly developed implantable sensors for monitoring the implantable artificial heart system were useful for sensing driving condition, thus possibly useful for the implantable devices for clinical usage.
Collapse
|
14
|
Abstract
To develop a total artificial heart (TAH) pump system, we created a design paying particular attention to durability and cost. We adopted a pneumatically driven sac type artificial heart, where the configuration of the sac was decided according to the methodology of flow visualization. Its configuration is almost round to achieve as little stagnation as possible and a low turbulent flow. The main body of the sac was made using polyvinyl chloride (PVC) paste. The paste was poured into an external mold, and heated in a hot air drying oven. Coating was performed using polyurethane. The basic performance of this pump system was tested using a model circulation circuit, and a fitting study through acute animal experiment, using a healthy adult goat, was carried out. As for the TAH produced experimentally, a pump output exceeding 5.0 l/min in the model circulation circuit was provided. Implantation in the internal pleural cavity of a healthy adult goat, 55 kg in weight, proved possible and quite easy in comparison. It is thought that a more refined design in the connector part is desirable. Furthermore, a chronic experiment with the TAH will be carried out, and examination will need to be repeated in the future.
Collapse
|
15
|
|
16
|
Abstract
In order to analyze the hemodynamic parameters in prosthetic circulation as an entity and not as decomposed parts, non linear mathematical analyzing techniques, including the fractal dimension analyzing theory, were utilized. Two pneumatically actuated ventricular assist devices were implanted, as biventricular bypasses (BVB), in chronic animal experiments, using four healthy adult goats. For the comparison between the natural and prosthetic circulation in the same animals, the BVB type complete prosthetic circulation model with ventricular fibrillation, was adopted. All hemodynamic parameters with natural and prosthetic circulation were recorded under awake conditions, and calculated with a personal computer system. Using the non-linear mathematical technique, the arterial blood pressure waveform was embedded into the return map as the beat-to-beat time series data and fractal dimension analysis were performed to analyze the reconstructed attractor. By the use of the Box counting method, fractal dimension analysis of the hemodynamics was performed. Return map of the hemodynamics during natural and artificial circulation showed fractal characteristics, and fractal dimension analysis of the arterial blood pressure revealed the fact that lower dimensional fractal dynamics were evident during prosthetic circulation. Fractal time series data is suggested to have robustness and error resistance, thus our results suggest that the circulatory regulatory system with an artificial heart may have these desired characteristics.
Collapse
|
17
|
Strange Hemodynamic Attractor Parameter with 1/R Total Artificial Heart Automatic Control Algorithm. Int J Artif Organs 2018. [DOI: 10.1177/039139889601900508] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
To evaluate the automatic control algorithm of the total artificial heart (TAH) as an entity, and not just as parts, a non-linear mathematical analyzing technique including chaos theory was utilized. Chronic experiments on the biventricular bypass type artificial heart implantation were performed in healthy adult goats after the natural ventricles were removed. Hemodynamic time series data were recorded under the awake standing condition with TAH 1/R and fixed driving. Time series data were recorded on a magnetic tape and analyzed on a personal computer system with an A-D converter. Using the nonlinear mathematical technique, the time series data were embedded into the phase space and the Lyapunov numerical method was carried out for the quantitative evaluation of the sensitive dependence on the initial condition of the reconstructed attractor. Calculation of the largest Lyapunov exponents suggested that the reconstructed attractor of the left pump output during TAH 1/R control was a larger dimensional strange attractor, a characteristic pattern of deterministic chaos. A total system indicating chaotic dynamics was thought to be a flexible and intelligent control system. Thus, our results suggest that 1/R TAH control may be suitable for the biventricular assist type total artificial heart.
Collapse
|
18
|
Issues with the surgical treatment of antiresorptive agent-related osteonecrosis of the jaws. Oral Dis 2018; 24:52-56. [DOI: 10.1111/odi.12783] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Revised: 09/18/2017] [Accepted: 09/19/2017] [Indexed: 11/30/2022]
|
19
|
WE-DE-207B-02: Detection of Masses On Mammograms Using Deep Convolutional Neural Network: A Feasibility Study. Med Phys 2016. [DOI: 10.1118/1.4957862] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
20
|
WE-AB-303-02: A Real-Time Homography-Based Algorithm for Markerless Deformable Lung Tumor Motion Tracking Using KV X-Ray Fluoroscopy. Med Phys 2015. [DOI: 10.1118/1.4925867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
21
|
Development of portable long counter with two different moderator materials. RADIATION PROTECTION DOSIMETRY 2014; 161:144-148. [PMID: 24489018 DOI: 10.1093/rpd/nct345] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
A portable, light-weight long counter (LC) with small dimensions was developed. This LC consists of a (3)He thermal neutron counter, a cylindrical moderator and outer shields. It was designed to have an almost flat response in a neutron energy range of 0.4 eV to 5 MeV. The portable LC has a radius of 11 cm and a length of 39 cm. Its weight was successfully reduced to 15 kg. Polystyrene was employed instead of polyethylene for the front part of the moderator in order to increase the sensitivity to low-energy neutrons. The response function calculated using the MCNP code was consistent with the results of experiments using monoenergetic neutron calibration fields.
Collapse
|
22
|
An attempt to decrease anisotropic emissions of neutrons from a cylindrical 241Am-Be-encapsulation source. RADIATION PROTECTION DOSIMETRY 2014; 161:166-170. [PMID: 24218643 DOI: 10.1093/rpd/nct270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
An attempt to decrease the anisotropic emissions of neutrons from a cylindrical (241)Am-Be-encapsulated X3 source was conducted with Monte Carlo calculations and experiments. The influence of metal materials and shapes of the external casing to the anisotropy factor were focussed on. Results obtained by calculations using MCNP4C implied that a light and spherical-shaped external casing decreases the anisotropic emission of neutrons. Experimental results using the spherical-shaped aluminium protection case also revealed that the anisotropy factor was close to 1.0 with wide zenith angle ranges.
Collapse
|
23
|
Photon dose mixed in monoenergetic neutron calibration fields using 7Li(p,n)7Be reaction. RADIATION PROTECTION DOSIMETRY 2014; 161:149-152. [PMID: 24482042 DOI: 10.1093/rpd/nct360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The ambient dose equivalents H*(10) of photons mixed in the 144, 250 and 565 keV monoenergetic neutron fields were evaluated using measurements from an NaI(Tl) detector and calculations done using the MCNP-ANT code. It was found that H*(10) of the photons produced in the target assembly dominates the dose, particularly near the target. The H*(10) of the photons produced in other materials in the field increases with the increase in distance from the target and could not be neglected at a large distance from the target. The ratios of the H*(10) of the mixed photons to that of the monoenergetic neutrons for 144, 250 and 565 keV neutron fields, were evaluated to be below 5.5, 6.9 and 1.5 %, respectively. The ratios were calculated at calibration points between 100 and 500 cm from the target.
Collapse
|
24
|
Clinicopathological analyses and predictive factors for loco-regional recurrences in patients with oral squamous cell carcinoma. J Oral Maxillofac Surg 2014. [DOI: 10.1016/j.joms.2014.06.267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
25
|
An experimental study on the effects of platelet rich plasma on the woundhealing of tooth extraction-related bone defects. J Oral Maxillofac Surg 2014. [DOI: 10.1016/j.joms.2014.06.135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
26
|
TH-E-17A-11: Tracking Tumor’s Boundary in MV Image Sequences for Image-Guided Radiation Therapy. Med Phys 2014. [DOI: 10.1118/1.4889686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
27
|
Lack of changes in carotid artery compliance with systemic nitric oxide synthase inhibition. J Hum Hypertens 2014; 28:494-9. [PMID: 24401955 DOI: 10.1038/jhh.2013.137] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2013] [Revised: 11/04/2013] [Accepted: 11/21/2013] [Indexed: 11/09/2022]
Abstract
Proximal large elastic arteries (ascending aorta and carotid artery) have an important role in buffering the pulsatile pressure generated from the left ventricle, which forwards continuous peripheral blood flow and protects the brain microcirculation from end-organ damage. Although compliance of distal conduit arteries (extremities' arteries) is attenuated by the nitric oxide synthase (NOS) inhibition, it is yet unknown whether compliance of proximal elastic arteries changes by the systemic NOS inhibition. To address this question, we measured central artery compliance in 17 young adults (26±1 years) who underwent intravenous infusions of N(G)-monomethyl-L-arginine (L-NMMA) or saline (placebo) on separate days. Following the systemic NOS inhibition, the mean arterial pressure (MAP), total peripheral resistance and aortic augmentation index were significantly increased. However, carotid artery compliance was not affected significantly (from 0.10±0.01 to 0.11±0.01 mm2) per mmHg) and the β-stiffness index (an index of arterial compliance adjusted for the distending pressure) tended to decrease (from 6.63±0.35 to 6.06±0.42 a.u., P=0.07). These parameters were not altered with saline infusion. Changes in the β-stiffness index tended to correlate negatively with the corresponding changes in MAP (r = -0.31, P=0.07). These results suggest that carotid artery compliance remains unchanged during the systemic NOS inhibition in spite of systemic vasoconstriction.
Collapse
|
28
|
Evaluation of the effects of platelet rich plasma on the healing of tooth extraction bone defects: an experimental study. Int J Oral Maxillofac Surg 2013. [DOI: 10.1016/j.ijom.2013.07.242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
29
|
Vertical distraction osteogenesis of a nonvascularized iliac bone in a reconstructed mandible: a report of 3 cases. Int J Oral Maxillofac Surg 2013. [DOI: 10.1016/j.ijom.2013.07.609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
30
|
WE-A-134-03: A Kernel-Based Method for Non-Rigid Tumor Tracking in KV Image Sequence. Med Phys 2013. [DOI: 10.1118/1.4815509] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
31
|
Examination of mitral regurgitation with a goat heart model for the development of intelligent artificial papillary muscle. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2012:6649-52. [PMID: 23367454 DOI: 10.1109/embc.2012.6347519] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Annuloplasty for functional mitral or tricuspid regurgitation has been made for surgical restoration of valvular diseases. However, these major techniques may sometimes be ineffective because of chamber dilation and valve tethering. We have been developing a sophisticated intelligent artificial papillary muscle (PM) by using an anisotropic shape memory alloy fiber for an alternative surgical reconstruction of the continuity of the mitral structural apparatus and the left ventricular myocardium. This study exhibited the mitral regurgitation with regard to the reduction in the PM tension quantitatively with an originally developed ventricular simulator using isolated goat hearts for the sophisticated artificial PM. Aortic and mitral valves with left ventricular free wall portions of isolated goat hearts (n=9) were secured on the elastic plastic membrane and statically pressurized, which led to valvular leaflet-papillary muscle positional change and central mitral regurgitation. PMs were connected to the load cell, and the relationship between the tension of regurgitation and PM tension were measured. Then we connected the left ventricular specimen model to our hydraulic ventricular simulator and achieved hemodynamic simulation with the controlled tension of PMs.
Collapse
|
32
|
Structural Evolution in Photoactive Yellow Protein Studied by Femtosecond Stimulated Raman Spectroscopy. EPJ WEB OF CONFERENCES 2013. [DOI: 10.1051/epjconf/20134107008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
33
|
Dark excited states of carotenoid in light harvesting complex probing with femtosecond stimulated Raman spectroscopy. EPJ WEB OF CONFERENCES 2013. [DOI: 10.1051/epjconf/20134108007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
34
|
Detection and avoiding ventricular suction of ventricular assist devices. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2012; 2006:402-5. [PMID: 17282199 DOI: 10.1109/iembs.2005.1616430] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Continuous flow blood pumps, such as axial flow and centrifugal pumps, have been gaining interest as circulatory devices for total artificial hearts (TAHs) and a biventricular assist device (BVAD) because of their smaller size and simpler structure compared to pulsatile pumps. However, continuous flow pumps are more prone to suction of the left ventricle than pulsatile pumps are. Sudden increases in flow rate to meet changes in physiological demand, especially in the left pump, often cause ventricle suction. In this study, a control algorithm to prevent suction from occurring in the left ventricle by controlling the rotational speed of the right pump, instead of reducing the cardiac output of the left pump, was developed and investigated. The method was tested in acute animal experiments with calves. The results indicate that this proposed method is capable of preventing suction and could simultaneously maintain circulatory control. A key advantage of this control system is that flow rates can be maximized while avoiding ventricle suction conditions particularly when the circulatory system is unstable such as in a the first few days after operation.
Collapse
|
35
|
Low-level motion analysis of color and luminance for perception of 2D and 3D motion. J Vis 2012; 12:12.6.33. [DOI: 10.1167/12.6.33] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
36
|
SU-D-BRA-02: An Extended Time-Variant Seasonal Autoregressive Model-Based Prediction for Irregular Breathing Motion Tracking. Med Phys 2012; 39:3616. [DOI: 10.1118/1.4734680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
37
|
SU-E-J-135: 3-D Fourier-Based Volumetric Registration for Estimating Intra-Fractional Lung Tumor Motion. Med Phys 2012; 39:3683. [DOI: 10.1118/1.4734971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
38
|
|
39
|
Structural design of a newly developed pediatric circulatory assist device for Fontan circulation by using shape memory alloy fiber. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2011; 2011:8353-8355. [PMID: 22256284 DOI: 10.1109/iembs.2011.6092060] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Total cavopulmonary connection (TCPC) is commonly applied for the surgical treatment of congenital heart disease such as single ventricle in pediatric patients. Patients with no ventricle in pulmonary circulation are treated along with Fontan algorithm, in which the systemic venous return is diverted directly to the pulmonary artery without passing through subpulmonary ventricle. In order to promote the pulmonary circulation after Fontan procedure, we developed a newly designed pulmonary circulatory assist device by using shape memory alloy fibers. We developed a pulmonary circulatory assist device as a non-blood contacting mechanical support system in pediatric patients with TCPC. The device has been designed to be installed like a cuff around the ePTFE TCPC conduit, which can contract from outside. We employed a covalent type functional anisotropic shape memory alloy fiber (Biometal, Toki Corporation, Tokyo Japan) as a servo actuator of the pulmonary circulatory assist device. The diameter of this fiber was 100 microns, and its contractile frequency was 2-3 Hz. Heat generation with electric current contracts these fibers and the conduit. The maximum contraction ratio of this fiber is about 7% in length. In order to extend its contractile ratio, we fabricated and installed mechanical structural units to control the length of fibers. In this study, we examined basic contractile functions of the device in the mock system. As a result, the internal pressure of the conduit increased to 63 mmHg by the mechanical contraction under the condition of 400 msec-current supply in the mock examination with the overflow tank of 10 mmHg loading.
Collapse
|
40
|
Multi-Component Structure of Roland-Morris Disability Questionnaire (RDQ), a Lumbago-Specific QOL (Quality of Life) Measure. JAPANESE CLINICAL MEDICINE 2011; 2:9-14. [PMID: 23885184 PMCID: PMC3699469 DOI: 10.4137/jcm.s6224] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Lumbago is one of the most prevalent symptoms in patients with osteoporotic vertebral fracture. Roland-Morris Disability Questionnaire (RDQ) is a quality of life (QOL) questionnaire targeted for evaluating lumbago. Although total score is the usual way of analysis, we have tried to make more use of it by subscale analysis. Forty-four osteoporotic patients were evaluated for their QOL using RDQ and SF-8; a widely accepted generic (non disease-specific) QOL questionnaire. Subscales and summary scores of SF-8 were significantly lower than Japanese norm. Patients with fracture had significantly lower scores including RDQ. Multiple regression analysis has shown that total score of RDQ was significantly contributed by bodily pain as well as other subscales of SF-8. Principal component analysis has revealed that RDQ consists of two components representing general, and mental or social aspect of lumbago. Defining the component structure and determining the procedure to obtain the subscales would make the most use of RDQ, and contribute to the better evaluation of patients with lumbago.
Collapse
|
41
|
Evaluation of target photon dose mixed in mono-energetic neutron fields using 7Li(p,n)7Be reaction. RADIAT MEAS 2010. [DOI: 10.1016/j.radmeas.2010.06.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
42
|
Clinical study on prognostic factors for autotransplantation of teeth with complete root formation. Int J Oral Maxillofac Surg 2010; 39:1193-203. [PMID: 20630706 DOI: 10.1016/j.ijom.2010.06.018] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2008] [Revised: 05/18/2010] [Accepted: 06/14/2010] [Indexed: 10/19/2022]
Abstract
Autotransplantation is often performed to replace a missing tooth, but tooth autotransplantation has been reported in fewer teeth with complete root formation than those with incomplete root formation. The aim of this prospective study was to evaluate the factors that affect the prognosis of autotransplantation of teeth with complete root formation. 109 patients with 117 transplants were studied. Of the 117 transplants investigated, 14 (12%) failed during the observation period. The overall 1-year survival rate was 96%; the 5-year survival rate was 84%. The major causes of failure were unsuccessful initial healing and replacement root resorption with periodontal inflammation. Factors significantly associated with unsuccessful transplantation, in single factor analysis, were age 40 years or more, molar tooth as donor, probing pocket depth to 4mm or more, history of root canal treatment, multi-rooted teeth and fixation with sutures. Pocket depth of 4mm or more and history of root canal treatment appeared to increase the risk of unsuccessful transplantation in multivariate analysis. It is suggested that the pocket depth of the donor tooth and history of root canal treatment are related to the healing of paratransplantal tissue and root resorption.
Collapse
|
43
|
SU-GG-J-55: Simultaneous Estimation of Lung Tumor Image and Intrafractional Motion without Implanted Markers Using KV-X-Ray Fluoroscopy for Image-Guided Radiotherapy. Med Phys 2010. [DOI: 10.1118/1.3468279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
44
|
SU-HH-BRB-10: Adaptive Seasonal Autoregressive Model Based Intrafractional Lung Tumor Motion Prediction for Continuously Irradiation. Med Phys 2010. [DOI: 10.1118/1.3469028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
45
|
Hemodynamics of the radial artery, the site of traditional pulse diagnosis. Eur J Integr Med 2009. [DOI: 10.1016/j.eujim.2009.08.086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
46
|
Changes of blood flow volume in the superior mesenteric artery and brachial artery with abdominal thermal stimulation. Eur J Integr Med 2009. [DOI: 10.1016/j.eujim.2009.08.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
47
|
Abstract
AIM Habitual aerobic exercise results in a significant increase in central arterial compliance. Endothelin-1 (ET-1) is a potent endothelium-derived vasoconstrictor peptide and could play a role in mediating the habitual aerobic exercise-induced increase in central arterial compliance. The aim of the present study was to examine whether ET-1 is involved in the mechanisms underlying the increase in central arterial compliance with aerobic exercise training. METHODS Seven apparently healthy middle-aged and older (60 +/- 3 years) adults underwent systemic endothelin-A/B (ET(A/B))-receptor blockade (500 mg of Tracleer) before and after 12 weeks of aerobic exercise training (70 +/- 1% of maximal heart rate, 44 +/- 2 min day(-1), 4.4 +/- 0.1 days week(-1)). RESULTS Basal carotid arterial compliance (via simultaneous B-mode ultrasound and arterial applanation tonometry on the common carotid artery) increased significantly after exercise training. Resting plasma ET-1 concentration decreased significantly after exercise training. Before exercise intervention, carotid arterial compliance increased significantly with the administration of the ET(A/B)-receptor blockade. After training, however, increases in carotid arterial compliance previously observed with the ET(A/B)-receptor blockade before training were abolished. CONCLUSIONS Regular aerobic exercise training enhances central arterial compliance in middle-aged and older humans. The increase in arterial compliance was associated with the corresponding reduction in plasma ET-1 concentration as well as the elimination of ET-1-mediated vascular tone. These results suggest that reductions in ET-1 may be an important mechanism underlying the beneficial effect of exercise training on central artery compliance.
Collapse
|
48
|
Sensorless control for a sophisticated artificial myocardial contraction by using shape memory alloy fibre. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2009; 2008:711-4. [PMID: 19162754 DOI: 10.1109/iembs.2008.4649251] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The authors have been developing an artificial myocardium, which is capable of supporting natural contractile function from the outside of the ventricle. The system was originally designed by using sophisticated covalent shape memory alloy fibres, and the surface did not implicate blood compatibility. The purpose of our study on the development of artificial myocardium was to achieve the assistance of myocardial functional reproduction by the integrative small mechanical elements without sensors, so that the effective circulatory support could be accomplished. In this study, the authors fabricated the prototype artificial myocardial assist unit composed of the sophisticated shape memory alloy fibre (Biometal), the diameter of which was 100 microns, and examined the mechanical response by using pulse width modulation (PWM) control method in each unit. Prior to the evaluation of dynamic characteristics, the relationship between strain and electric resistance and also the initial response of each unit were obtained. The component for the PWM control was designed in order to regulate the myocardial contractile function, which consisted of an originally-designed RISC microcomputer with the input of displacement, and its output signal was controlled by pulse wave modulation method. As a result, the optimal PWM parameters were confirmed and the fibrous displacement was successfully regulated under the different heat transfer conditions simulating internal body temperature as well as bias tensile loading. Then it was indicated that this control theory might be applied for more sophisticated ventricular passive or active restraint by the artificial myocardium on physiological demand.
Collapse
|
49
|
Assessment of synchronization measures for effective ventricular support by using the shape memory alloy fibred artificial myocardium in goats. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2009; 2009:3047-3050. [PMID: 19964283 DOI: 10.1109/iembs.2009.5333627] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Thromboembolic and haemorrhagic complications are the primary causes of mortality and morbidity in patients with artificial hearts, which are known to be induced by the interactions between blood flow and artificial material surfaces. The authors have been developing a new mechanical artificial myocardial assist device by using a sophisticated shape memory alloy fibre in order to achieve the mechanical cardiac support from outside of the heart without a direct blood contacting surface. The original material employed as the actuator of artificial myocardial assist devices was 100um fibred-shaped, which was composed of covalent and metallic bonding structure and designed to generate 4-7 % shortening by Joule heating induced by the electric current input. In this study, we focused on the synchronization of the actuator with native cardiac function, and the phase delay parameter was examined in animal experiments using Saanen goats. Total weight of the device including the actuator was around 150g, and the electric power was supplied transcutaneously. The device could be successfully installed into thoracic cavity, which was able to be girdling the left ventricle. The contraction of the device could be controlled by the originally designed microcomputer. The mechanical contraction signal input had been transmitted with the phase delay of 50-200 msec after the R-wave of ECG, and hemodynamic changes were investigated. Cardiac output and systolic left ventricular pressure were elevated with 20% delay of cardiac cycle by 27% and 7%, respectively, although there was smaller difference under the condition of the delay of over 30%. Therefore, it was suggested that the synchronization measures should be examined in order to achieve sophisticated ventricular passive/active support on physiological demand.
Collapse
|
50
|
Effect of 12 weeks of moderate-intensity resistance training on arterial stiffness: a randomised controlled trial in women aged 32-59 years. Br J Sports Med 2008; 43:615-8. [PMID: 18927168 DOI: 10.1136/bjsm.2008.052126] [Citation(s) in RCA: 77] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
BACKGROUND Resistance training has been increasingly incorporated into the overall exercise programme because of its effect on muscle strength, functional capacity and osteoporosis. High-intensity resistance training increases arterial stiffness. However, the effect of moderate-intensity resistance training on arterial stiffness is unknown. OBJECTIVE To determine whether 12 weeks of moderate-intensity resistance training increases arterial stiffness in middle-aged women. METHODS 35 middle-aged women (age range 32 to 59 years) volunteered to participate. The subjects were randomly assigned to one of three groups: resistance training (RT) group, aerobic exercise training (AET) group or control group. The RT and AET groups performed 12 weeks of moderate-intensity resistance training or aerobic exercise training (two days/week). RESULTS In the RT group, one-repetition maximum strength significantly increased after the intervention. Interestingly, aortic (carotid-femoral) pulse wave velocity (PWV; an index of arterial stiffness), and peripheral (femoral-ankle) PWV did not change with moderate-intensity resistance training. In contrast, in the AET group, carotid-femoral PWV significantly decreased after the intervention. Resistance training and aerobic exercise training did not affect blood pressure. CONCLUSIONS This study found that moderate-intensity resistance training did not increase arterial stiffness in middle-aged women, which may have great importance for health promotion with resistance training.
Collapse
|