1
|
Perioperative implications of patients with alpha gal allergies. J Clin Anesth 2023; 86:111056. [PMID: 36682226 PMCID: PMC11087933 DOI: 10.1016/j.jclinane.2023.111056] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 12/14/2022] [Accepted: 01/15/2023] [Indexed: 01/21/2023]
Abstract
Alpha Gal Syndrome (AGS) is an emerging immune response to mammalian products (MP) containing the oligosaccharide galactose-α-1,3 galactose (α-Gal) which includes meats and inactive ingredients in certain medications. This becomes clinically important in the perioperative realm as MPs are commonly found in the operating room, and pre- and post-operative settings, and can trigger responses as severe as anaphylaxis. In this review, authors discuss the epidemiology, diagnosis and treatment of AGS reactions. Additionally, strategies are explored in order to screen and prevent exposure to MP with a multidisciplinary approach. While this emerging allergy is still not fully understood, it is of paramount importance that all anesthesia providers recognize the implications of MP exposure in AGS patients and ultimately prevent harm in this highly vulnerable population.
Collapse
|
2
|
Design and Implementation of a Rat Ex Vivo Lung Perfusion Model. J Vis Exp 2023. [PMID: 37306411 DOI: 10.3791/64740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023] Open
Abstract
Ex vivo lung preparations are a useful model that can be translated to many different fields of research, complementing corresponding in vivo and in vitro models. Laboratories wishing to use isolated lungs need to be aware of important steps and inherent challenges to establish a setup that is affordable, reliable, and that can be easily adapted to fit the topic of interest. This paper describes a DIY (do it yourself) model for ex vivo rat lung ventilation and perfusion to study drug and gas effects on pulmonary vascular tone, independent of changes in cardiac output. Creating this model includes a) the design and construction of the apparatus, and b) the lung isolation procedure. This model results in a setup that is more cost-effective than commercial alternatives and yet modular enough to adapt to changes in specific research questions. Various obstacles had to be resolved to ensure a consistent model that is capable of being used for a variety of different research topics. Once established, this model has proven to be highly adaptable to different questions and can easily be altered for different fields of study.
Collapse
|
3
|
Newly Developed Di-Block Copolymer-Based Cell Membrane Stabilizers Protect Mouse Coronary Artery Endothelial Cells against Hypoxia/Reoxygenation Injury. Cells 2023; 12:1394. [PMID: 37408228 PMCID: PMC10216390 DOI: 10.3390/cells12101394] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 05/05/2023] [Accepted: 05/11/2023] [Indexed: 07/07/2023] Open
Abstract
Reperfusion after ischemia causes additional cellular damage, known as reperfusion injury, for which there is still no effective remedy. Poloxamer (P)188, a tri-block copolymer-based cell membrane stabilizer (CCMS), has been shown to provide protection against hypoxia/reoxygenation (HR) injury in various models by reducing membrane leakage and apoptosis and improving mitochondrial function. Interestingly, substituting one of its hydrophilic poly-ethylene oxide (PEO) blocks with a (t)ert-butyl terminus added to the hydrophobic poly-propylene oxide (PPO) block yields a di-block compound (PEO-PPOt) that interacts better with the cell membrane lipid bi-layer and exhibits greater cellular protection than the gold standard tri-block P188 (PEO75-PPO30-PEO75). For this study, we custom-made three different new di-blocks (PEO113-PPO10t, PEO226-PPO18t and PEO113-PPO20t) to systemically examine the effects of the length of each polymer block on cellular protection in comparison to P188. Cellular protection was assessed by cell viability, lactate dehydrogenase release, and uptake of FM1-43 in mouse artery endothelial cells (ECs) following HR injury. We found that di-block CCMS were able to provide the same or better EC protection than P188. Our study provides the first direct evidence that custom-made di-block CCMS can be superior to P188 in improving EC membrane protection, raising their potential in treating cardiac reperfusion injury.
Collapse
|
4
|
Peripheral Intravenous Waveform Analysis Responsiveness to Subclinical Hemorrhage in a Rat Model. Anesth Analg 2023; 136:941-948. [PMID: 37058731 DOI: 10.1213/ane.0000000000006349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/16/2023]
Abstract
BACKGROUND Early detection and quantification of perioperative hemorrhage remains challenging. Peripheral intravenous waveform analysis (PIVA) is a novel method that uses a standard intravenous catheter to detect interval hemorrhage. We hypothesize that subclinical blood loss of 2% of the estimated blood volume (EBV) in a rat model of hemorrhage is associated with significant changes in PIVA. Secondarily, we will compare PIVA association with volume loss to other static, invasive, and dynamic markers. METHODS Eleven male Sprague Dawley rats were anesthetized and mechanically ventilated. A total of 20% of the EBV was removed over ten 5 minute-intervals. The peripheral intravenous pressure waveform was continuously transduced via a 22-G angiocatheter in the saphenous vein and analyzed using MATLAB. Mean arterial pressure (MAP) and central venous pressure (CVP) were continuously monitored. Cardiac output (CO), right ventricular diameter (RVd), and left ventricular end-diastolic area (LVEDA) were evaluated via transthoracic echocardiogram using the short axis left ventricular view. Dynamic markers such as pulse pressure variation (PPV) were calculated from the arterial waveform. The primary outcome was change in the first fundamental frequency (F1) of the venous waveform, which was assessed using analysis of variance (ANOVA). Mean F1 at each blood loss interval was compared to the mean at the subsequent interval. Additionally, the strength of the association between blood loss and F1 and each other marker was quantified using the marginal R2 in a linear mixed-effects model. RESULTS PIVA derived mean F1 decreased significantly after hemorrhage of only 2% of the EBV, from 0.17 to 0.11 mm Hg, P = .001, 95% confidence interval (CI) of difference in means 0.02 to 0.10, and decreased significantly from the prior hemorrhage interval at 4%, 6%, 8%, 10%, and 12%. Log F1 demonstrated a marginal R2 value of 0.57 (95% CI 0.40-0.73), followed by PPV 0.41 (0.28-0.56) and CO 0.39 (0.26-0.58). MAP, LVEDA, and systolic pressure variation displayed R2 values of 0.31, and the remaining predictors had R2 values ≤0.2. The difference in log F1 R2 was not significant when compared to PPV 0.16 (95% CI -0.07 to 0.38), CO 0.18 (-0.06 to 0.04), or MAP 0.25 (-0.01 to 0.49) but was significant for the remaining markers. CONCLUSIONS The mean F1 amplitude of PIVA was significantly associated with subclinical blood loss and most strongly associated with blood volume among the markers considered. This study demonstrates feasibility of a minimally invasive, low-cost method for monitoring perioperative blood loss.
Collapse
|
5
|
High central venous pressure amplitude predicts successful defibrillation in a porcine model of cardiac arrest. Resuscitation 2023; 185:109716. [PMID: 36736947 PMCID: PMC11087940 DOI: 10.1016/j.resuscitation.2023.109716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 01/22/2023] [Accepted: 01/24/2023] [Indexed: 02/04/2023]
Abstract
AIM Increasing venous return during cardiopulmonary resuscitation (CPR) has been shown to improve hemodynamics during CPR and outcomes following cardiac arrest (CA). We hypothesized that a high central venous pressure amplitude (CVP-A), the difference between the maximum and minimum central venous pressure during chest compressions, could serve as a robust predictor of return of spontaneous circulation (ROSC) in addition to traditional measurements of coronary perfusion pressure (CPP) and end-tidal CO2 (etCO2) in a porcine model of CA. METHODS After 10 min of ventricular fibrillation, 9 anesthetized and intubated female pigs received mechanical chest compressions with active compression/decompression (ACD) and an impedance threshold device (ITD). CPP, CVP-A and etCO2 were measured continuously. All groups received biphasic defibrillation (200 J) at minute 4 of CPR and were classified into two groups (ROSC, NO ROSC). Mean values were analyzed over 3 min before defibrillation by repeated-measures Analysis of Variance and receiver operating characteristic (ROC). RESULTS Five animals out of 9 experienced ROSC. CVP-A showed a statistically significant difference (p = 0.003) between the two groups during 3 min of CPR before defibrillation compared to CPP (p = 0.056) and etCO2 (p = 0.064). Areas-under-the-curve in ROC analysis for CVP-A, CPP and etCO2 were 0.94 (95% Confidence Interval 0.86, 1.00), 0.74 (0.54, 0.95) and 0.78 (0.50, 1.00), respectively. CONCLUSION In our study, CVP-A was a potentially useful predictor of successful defibrillation and return of spontaneous circulation. Overall, CVP-A could serve as a marker for prediction of ROSC with increased venous return and thereby monitoring the beneficial effects of ACD and ITD.
Collapse
|
6
|
Current and Novel Experimental Methods in Ischemia/Reperfusion Research: From Cutting-Edge Models to Innovative Therapies. J Vis Exp 2023:10.3791/64995. [PMID: 37255424 PMCID: PMC11087941 DOI: 10.3791/64995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2024] Open
|
7
|
P188 Therapy in In Vitro Models of Traumatic Brain Injury. Int J Mol Sci 2023; 24:3334. [PMID: 36834743 PMCID: PMC9961452 DOI: 10.3390/ijms24043334] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 01/26/2023] [Accepted: 01/30/2023] [Indexed: 02/11/2023] Open
Abstract
Traumatic brain injury (TBI) is a significant cause of morbidity and mortality worldwide. Varied mechanisms of injury contribute to the heterogeneity of this patient population as demonstrated by the multiple published grading scales and diverse required criteria leading to diagnoses from mild to severe. TBI pathophysiology is classically separated into a primary injury that is characterized by local tissue destruction as a result of the initial blow, followed by a secondary phase of injury constituted by a score of incompletely understood cellular processes including reperfusion injury, disruption to the blood-brain barrier, excitotoxicity, and metabolic dysregulation. There are currently no effective pharmacological treatments in the wide-spread use for TBI, in large part due to challenges associated with the development of clinically representative in vitro and in vivo models. Poloxamer 188 (P188), a Food and Drug Administration-approved amphiphilic triblock copolymer embeds itself into the plasma membrane of damaged cells. P188 has been shown to have neuroprotective properties on various cell types. The objective of this review is to provide a summary of the current literature on in vitro models of TBI treated with P188.
Collapse
|
8
|
Buffer glucose adjustment affects myocardial function after ischemia-reperfusion in long-term diabetic rat isolated hearts. Physiol Rep 2022; 10:e15387. [PMID: 36324287 PMCID: PMC9630758 DOI: 10.14814/phy2.15387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Revised: 06/22/2022] [Accepted: 06/24/2022] [Indexed: 11/06/2022] Open
Abstract
Due to its comorbidities type 2 diabetes mellitus (T2DM) and hypertension, the Zucker Spontaneous Hypertensive Fatty (ZSF1) rat is a clinically relevant animal model when assessing ischemia-reperfusion (IR) injury. Most IR studies in hearts isolated from diabetic animals have been conducted at normal glucose concentrations, providing a different environment compared to in-vivo. We hypothesized IR injury to be attenuated in isolated hearts of diabetic ZSF1 rats when adjusting the Krebs-buffer (KB) to their in-vivo, i.e., elevated blood glucose (BG) levels. Diabetic and non-diabetic ZSF1 rats were anesthetized, hearts isolated and Langendorff-prepared. While standard KB was used for the non-diabetic and diabetic unadjusted groups, KB with glucose levels increased to each rat's prior BG level was used for the adjusted diabetic group. All hearts underwent 30 min ischemia and 120 min reperfusion. Diastolic contracture during ischemia and early reperfusion was delayed and temporarily attenuated in the adjusted compared to the unadjusted diabetic and the non-diabetic groups. The decrease in coronary flow on reperfusion was attenuated in diabetic animals. Left ventricular developed pressure and contractility were not different among the three groups. Infarct size was significantly lower in non-diabetic animals; buffer adjustment made no difference in diabetic animals. In our study, T2DM did not worsen myocardial function in ZSF1 rat isolated hearts. Since our results reveal that hearts with an adjusted glucose level exhibit an at least temporary improvement of function following IR, further studies should consider adapting glucose levels to create more realistic conditions in isolated, perfused hearts.
Collapse
|
9
|
Effect of Pre‐Conditioning with Copolymer‐Based Cell Membrane Stabilizer Poloxamer 188 on Adult Mouse Coronary Artery Endothelial Layer Integrity after Prolonged Hypoxia/Reoxygenation. FASEB J 2022. [DOI: 10.1096/fasebj.2022.36.s1.r5759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
10
|
Differential Effects of Reperfusion on Cardiac Mitochondrial Subpopulations in a Preclinical Porcine Model of Acute Myocardial Infarction. Front Cell Dev Biol 2022; 10:843733. [PMID: 35356287 PMCID: PMC8959812 DOI: 10.3389/fcell.2022.843733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2021] [Accepted: 02/03/2022] [Indexed: 11/28/2022] Open
Abstract
Acute myocardial infarction (AMI) leads to localized cardiac ischemia and can be fatal if untreated. Despite being treatable, the threat of ischemia-reperfusion (IR) injury remains high. Mitochondria are central to both propagation and mitigation of IR injury, and cardiac mitochondria are categorized into two major subtypes-subsarcolemmal and interfibrillar mitochondria (SSM and IFM, respectively). We hypothesized that, in our pre-clinical porcine model of AMI, SSM and IFM are differentially affected by reperfusion. AMI was induced in female pigs by balloon occlusion of the left anterior descending artery for 45 min, followed by 4 h of reperfusion. At the end of reperfusion, animals were euthanized. Cardiac SSM and IFM from the affected ischemic area and a nearby non-ischemic area were isolated to compare mitochondrial function using substrates targeting mitochondrial electron transport chain complexes I and II. Despite detecting overall significant differences in mitochondrial function including yield, mitochondrial S3 and S4 respirations, and calcium retention, consistent individual functional differences in the two mitochondrial subpopulations were not observed, both between the two mitochondrial subtypes, as well as between the ischemic and non-ischemic tissue. Nonetheless, this study describes the mitochondrial subtype response within the initial few hours of reperfusion in a clinically relevant model of AMI, which provides valuable information needed to develop novel mitochondrially targeted therapies for AMI.
Collapse
|
11
|
Simulated traumatic brain injury in in-vitro mouse neuronal and brain endothelial cell culture models. J Pharmacol Toxicol Methods 2022; 114:107159. [PMID: 35149185 DOI: 10.1016/j.vascn.2022.107159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 01/02/2022] [Accepted: 02/04/2022] [Indexed: 11/18/2022]
Abstract
Traumatic brain injury can lead to fatal outcomes such as disability and death. Every year, it affects many patients all over the world. Not only the primary ischemic event, but also the subsequent reperfusion can cause severe brain injury. This so-called ischemia/reperfusion injury combined with mechanical forces lead to cellular disruption. Hence, this paper describes a special in-vitro model, mimicking traumatic brain injury by combining both hypoxia/reoxygenation and compression to simulate ischemia/reperfusion injury as well as the mechanical effects that occur concurrently when suffering traumatic brain injury. Through this approach, stroke, concussion, and traumatic brain injury can be studied on different cell lines in a simplified way. We used two primary mouse brain cell cultures, namely neurons and endothelial cells. Our results show that for the different cell types, different timelines of hypoxia and compression need to be explored to achieve the optimal amount of cellular damage in order to effectively mimic traumatic brain injury. Thus, this model will be useful to test potential treatments of brain injury in future in-vitro studies.
Collapse
|
12
|
Development of a Cell Co-Culture Model to Mimic Cardiac Ischemia/Reperfusion In Vitro. J Vis Exp 2021. [PMID: 34723947 DOI: 10.3791/62913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Ischemic heart disease is the leading cause of death and disability worldwide. Reperfusion causes additional injury beyond ischemia. Endothelial cells (ECs) can protect cardiomyocytes (CMs) from reperfusion injury through cell-cell interactions. Co-cultures can help investigate the role of cell-cell interactions. A mixed co-culture is the simplest approach but is limited as isolated treatments and downstream analyses of single cell types are not feasible. To investigate whether ECs can dose-dependently attenuate CM cell damage and whether this protection can be further optimized by varying the contact distance between the two cell lines, we used Mouse Primary Coronary Artery Endothelial Cells and Adult Mouse Cardiomyocytes to test three types of cell culture inserts which varied in their inter-cell layer distance at 0.5, 1.0, and 2.0 mm, respectively. In CMs-only, cellular injury as assessed by lactate dehydrogenase (LDH) release increased significantly during hypoxia and further upon reoxygenation when the distance was 2.0 mm compared to 0.5 and 1.0 mm. When ECs and CMs were in nearly direct contact (0.5 mm), there was only a mild attenuation of the reoxygenation injury of CMs following hypoxia. This attenuation was significantly increased when the spatial distance was 1.0 mm. With 2.0 mm distance, ECs attenuated CM injury during both hypoxia and hypoxia/reoxygenation, indicating that sufficient culture distancing is necessary for ECs to crosstalk with CMs, so that secreted signal molecules can circulate and fully stimulate protective pathways. Our findings suggest, for the first time, that optimizing the EC/CM co-culture spatial environment is necessary to provide a favorable in vitro model for testing the role of ECs in CM-protection against simulated ischemia/reperfusion injury. The goal of this report is to provide a step-by-step approach for investigators to use this important model to their advantage.
Collapse
|
13
|
Poloxamer 188 Exerts Direct Protective Effects on Mouse Brain Microvascular Endothelial Cells in an In Vitro Traumatic Brain Injury Model. Biomedicines 2021; 9:1043. [PMID: 34440247 PMCID: PMC8393826 DOI: 10.3390/biomedicines9081043] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 08/13/2021] [Accepted: 08/16/2021] [Indexed: 12/04/2022] Open
Abstract
Traumatic Brain Injury (TBI), the main contributor to morbidity and mortality worldwide, can disrupt the cell membrane integrity of the vascular endothelial system, endangering blood-brain barrier function and threatening cellular subsistence. Protection of the vascular endothelial system might enhance clinical outcomes after TBI. Poloxamer 188 (P188) has been shown to improve neuronal function after ischemia/reperfusion (I/R) injury as well as after TBI. We aimed to establish an in vitro compression-type TBI model, comparing mild-to-moderate and severe injury, to observe the direct effects of P188 on Mouse Brain Microvascular Endothelial Cells (MBEC). Confluent MBEC were exposed to normoxic or hypoxic conditions for either 5 or 15 h (hours). 1 h compression was added, and P188 was administered during 2 h reoxygenation. A direct effect of P188 on MBEC was tested by assessing cell number/viability, cytotoxicity/membrane damage, metabolic activity, and total nitric oxide production (tNOp). While P188 enhanced cell number/viability, metabolic activity, and tNOp, an increase in cytotoxicity/membrane damage after mild-to-moderate injury was prevented. In severely injured MBEC, P188 improved metabolic activity only. P188, present during reoxygenation, influenced MBEC function directly in simulated I/R and compression-type TBI.
Collapse
|
14
|
Liver and Biliary Disease of Pregnancy and Anesthetic Implications: A Review. Anesth Analg 2021; 133:80-92. [PMID: 33687174 DOI: 10.1213/ane.0000000000005433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Liver and biliary disease complicates pregnancy in varying degrees of severity to the mother and fetus, and anesthesiologists may be asked to assist in caring for these patients before, during, and after birth of the fetus. Therefore, it is important to be familiar with how different liver diseases impact the pregnancy state. In addition, knowing symptoms, signs, and laboratory markers in the context of a pregnant patient will lead to faster diagnosis and treatment of such patients. This review article discusses changes in physiology of parturients, patients with liver disease, and parturients with liver disease. Next, general treatment of parturients with acute and chronic liver dysfunction is presented. The article progresses to specific liver diseases with treatments as they relate to pregnancy. And finally, important aspects to consider when anesthetizing parturients with liver disease are discussed.
Collapse
|
15
|
The Devil Is in the Detail. Otolaryngol Head Neck Surg 2021; 164:1359-1360. [PMID: 34060374 DOI: 10.1177/0194599820973243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
16
|
No Direct Postconditioning Effect of Poloxamer 188 on Mitochondrial Function after Ischemia Reperfusion Injury in Rat Isolated Hearts. Int J Mol Sci 2021; 22:4879. [PMID: 34063028 PMCID: PMC8124240 DOI: 10.3390/ijms22094879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Revised: 05/02/2021] [Accepted: 05/03/2021] [Indexed: 11/17/2022] Open
Abstract
Myocardial infarction is a leading cause for morbidity and mortality worldwide. The only viable treatment for the ischemic insult is timely reperfusion, which further exacerbates myocardial injury. Maintaining mitochondrial function is crucial in preserving cardiomyocyte function in ischemia reperfusion (IR) injury. Poloxamer (P) 188 has been shown to improve cardiac IR injury by improving cellular and mitochondrial function. The aim of this study was to show if P188 postconditioning has direct protective effects on mitochondrial function in the heart. Langendorff prepared rat hearts were subjected to IR injury ex-vivo and reperfused for 10 min with 1 mM P188 vs. vehicle. Cardiac mitochondria were isolated with 1 mM P188 vs. 1 mM polyethylene glycol (PEG) vs. vehicle by differential centrifugation. Mitochondrial function was assessed by adenosine triphosphate synthesis, oxygen consumption, and calcium retention capacity. Mitochondrial function decreased significantly after ischemia and showed mild improvement with reperfusion. P188 did not improve mitochondrial function in the ex-vivo heart, and neither further P188 nor PEG induced direct mitochondrial protection after IR injury in this model.
Collapse
|
17
|
Evaluation of In Vitro Neuronal Protection by Postconditioning with Poloxamer 188 Following Simulated Traumatic Brain Injury. Life (Basel) 2021; 11:316. [PMID: 33917288 PMCID: PMC8067401 DOI: 10.3390/life11040316] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 03/16/2021] [Accepted: 03/29/2021] [Indexed: 12/16/2022] Open
Abstract
Traumatic brain injury (TBI) leads to morbidity and mortality worldwide. Reperfusion after ischemia adds detrimental injury to cells. Ischemia/reperfusion (I/R) injures cells in a variety of ways including cell membrane disruption. Hence, methods to improve endogenous membrane resealing capacity are crucial. Poloxamer (P) 188, an amphiphilic triblock copolymer, was found to be effective against I/R and mechanical injury in various experimental settings. The aim of this study was to establish an in vitro mouse neuronal TBI model and, further, to investigate if postconditioning with P188 directly interacts with neurons after compression and simulated I/R injury, when administered at the start of reoxygenation. Cellular function was assessed by cell number/viability, mitochondrial viability, membrane damage by lactated dehydrogenase (LDH) release and FM1-43 incorporation as well as apoptosis-activation by Caspase 3. Five hours hypoxia ± compression with 2 h reoxygenation proved to be a suitable model for TBI. Compared to normoxic cells not exposed to compression, cell number and mitochondrial viability decreased, whereas membrane injury by LDH release/FM1-43 dye incorporation and Caspase 3 activity increased in cells exposed to hypoxic conditions with compression followed by reoxygenation. P188 did not protect neurons from simulated I/R and/or compression injury. Future research is indicated.
Collapse
|
18
|
Potential Effects of Poloxamer 188 on Rat Isolated Brain Mitochondria after Oxidative Stress In Vivo and In Vitro. Brain Sci 2021; 11:brainsci11010122. [PMID: 33477541 PMCID: PMC7831103 DOI: 10.3390/brainsci11010122] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/11/2021] [Accepted: 01/13/2021] [Indexed: 12/26/2022] Open
Abstract
Outcome after cerebral ischemia is often dismal. Reperfusion adds significantly to the ischemic injury itself. Therefore, new strategies targeting ischemia/reperfusion (I/R) injury are critically needed. Poloxamer (P)188, an amphiphilic triblock copolymer, is a highly promising pharmacological therapeutic as its capability to insert into injured cell membranes has been reported to protect against I/R injury in various models. Although mitochondrial function particularly profits from P188 treatment after I/R, it remains unclear if this beneficial effect occurs directly or indirectly. Here, rat isolated brain mitochondria underwent oxidative stress in vivo by asphyxial cardiac arrest or in vitro by the addition of hydrogen peroxide (H2O2) after isolation. Mitochondrial function was assessed by adenosine triphosphate synthesis, oxygen consumption, and calcium retention capacity. Both asphyxia and H2O2 exposure significantly impaired mitochondrial function. P188 did not preserve mitochondrial function after either injury mechanism. Further research is indicated.
Collapse
|
19
|
Poloxamer 188 Protects Isolated Adult Mouse Cardiomyocytes from Reoxygenation Injury. Pharmacol Res Perspect 2020; 8:e00639. [PMID: 33073927 PMCID: PMC7570448 DOI: 10.1002/prp2.639] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 05/28/2020] [Accepted: 06/01/2020] [Indexed: 12/13/2022] Open
Abstract
Reperfusion injury is a complex pathological event involving processes that can lead to further disruption of the cell membrane and function following an ischemic event. Return of blood flow allows for the needed reperfusion; however, for a period of time before remaining viable cells stabilize, reperfusion results in additional cellular injury. In cardiomyocytes, loss of membrane integrity allows abnormal influx of extracellular calcium, leading to hyper-contracture and cell death. Methods to improve the membrane integrity of cardiomyocytes overwhelmed by pathological disruptions, such as reperfusion injury, are needed to prevent cell death, because of the myocardium's limited ability to regenerate. Research has shown administration of the copolymer P(oloxamer) 188 before ischemia/reperfusion can protect cardiomyocytes through membrane stabilization. This study sought to determine whether the administration of P188 at the beginning of the clinically more relevant time of reperfusion after ischemia will attenuate any additional damage to cardiomyocytes by stabilizing membrane integrity to allow the cells to maintain function. Using an in-vitro cardiomyocyte model subjected to hypoxia/reoxygenation to simulate ischemia/reperfusion injury, we show that reoxygenation significantly potentiates the injury caused by hypoxia itself. P188, with its unique combination of hydrophobic and hydrophilic chemical properties, and only delivered at the beginning of reoxygenation, dose-dependently protected cardiomyocytes from injury due to reoxygenation by repairing cell membranes, decreasing calcium influx, and maintaining cellular morphology. Our study also shows the hydrophobic portion of P188 is necessary for the stabilization of cell membrane integrity in providing protection to cardiomyocytes against reoxygenation injury.
Collapse
|
20
|
Venous Waveform Analysis Correlates With Echocardiography in Detecting Hypovolemia in a Rat Hemorrhage Model. Semin Cardiothorac Vasc Anesth 2020; 25:11-18. [PMID: 32957831 DOI: 10.1177/1089253220960894] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
BACKGROUND Assessing intravascular hypovolemia due to hemorrhage remains a clinical challenge. Central venous pressure (CVP) remains a commonly used monitor in surgical and intensive care settings for evaluating blood loss, despite well-described pitfalls of static pressure measurements. The authors investigated an alternative to CVP, intravenous waveform analysis (IVA) as a method for detecting blood loss and examined its correlation with echocardiography. METHODS Seven anesthetized, spontaneously breathing male Sprague Dawley rats with right internal jugular central venous and femoral arterial catheters underwent hemorrhage. Mean arterial pressure (MAP), heart rate, CVP, and IVA were assessed and recorded. Hemorrhage was performed until each rat had 25% estimated blood volume removed. IVA was obtained using fast Fourier transform and the amplitude of the fundamental frequency (f1) was measured. Transthoracic echocardiography was performed utilizing a parasternal short axis image of the left ventricle during hemorrhage. MAP, CVP, and IVA were compared with blood removed and correlated with left ventricular end diastolic area (LVEDA). RESULTS All 7 rats underwent successful hemorrhage. MAP and f1 peak amplitude obtained by IVA showed significant changes with hemorrhage. MAP and f1 peak amplitude also significantly correlated with LVEDA during hemorrhage (R = 0.82 and 0.77, respectively). CVP did not significantly change with hemorrhage, and there was no significant correlation between CVP and LVEDA. CONCLUSIONS In this study, f1 peak amplitude obtained by IVA was superior to CVP for detecting acute, massive hemorrhage. In addition, f1 peak amplitude correlated well with LVEDA on echocardiography. Translated clinically, IVA might provide a viable alternative to CVP for detecting hemorrhage.
Collapse
|
21
|
Surgical Field Visualization during Functional Endoscopic Sinus Surgery: Comparison of Propofol- vs Desflurane-Based Anesthesia. Otolaryngol Head Neck Surg 2020; 163:835-842. [PMID: 32450733 DOI: 10.1177/0194599820921863] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
OBJECTIVE To assess if the type of general anesthetic affects bleeding and field visualization during endoscopic sinus surgery. STUDY DESIGN Prospective, randomized, controlled trial. SETTING Academic teaching hospital and Veterans Affairs hospital in the United States. SUBJECTS AND METHODS Seventy patients were randomized to 1 of 3 anesthetic regimens: (1) the volatile anesthetic desflurane (n = 22), (2) intravenous anesthesia with propofol (n = 25), or (3) a combination of propofol and desflurane (n = 23). Intravenous remifentanil was titrated to decrease the mean arterial pressure to 60 to 70 mm Hg but not ≥30% from baseline. Surgical bleeding scores were recorded along with bleeding rates and hemodynamic parameters, including cardiac output and systemic vascular resistance through pulse contour analysis from a radial arterial line. Statistics: multiple comparison tests and regression analyses; α = .05. RESULTS There were no differences in bleeding rate (median, 0.58, 0.85, 0.57 mL min-1), bleeding score (2.1, 2.0, 2.0), surgery duration (79, 81, 86 minutes), extubation time (9, 7, 8 minutes), recovery room time (65, 61, 61 minutes), or any hemodynamic parameters among groups 1 through 3, respectively. Group 1 required lower remifentanil infusions than group 2 (0.11 vs 0.26 µg kg-1 min-1; P = .01). The bleeding score correlated positively with height (P = .014) and the Lund-MacKay score (P = .013). Bilateral vs unilateral surgery led to longer surgery duration (P = .001) and recovery room time (P = .004). CONCLUSION When remifentanil is used for controlled hypotension, propofol has no advantage over desflurane to improve surgical field visualization during functional endoscopic sinus surgery.
Collapse
|
22
|
Intralipid Increases Nitric Oxide Release from Human Endothelial Cells During Oxidative Stress. JPEN J Parenter Enteral Nutr 2020; 45:295-302. [PMID: 32291784 DOI: 10.1002/jpen.1834] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Accepted: 03/06/2020] [Indexed: 12/18/2022]
Abstract
BACKGROUND Intralipid (ILP), a lipid emulsion, protects organs against ischemia/reperfusion (IR) injury. We hypothesized that ILP activates endothelial nitric oxide synthase (eNOS) and increases NO release from endothelial cells (ECs) through a fatty-acid translocase cluster of differentiation (CD36) mediated endocytotic mechanism, acting as a potentially protective paracrine signal during oxidative stress. METHODS Human umbilical-vein ECs were exposed to 1% ILP for 2 hours followed by oxidative stress with 0.2-mM hydrogen peroxide for 2 hours. Western blots were conducted with anti-CD36, dynamin-2, src-kinase-1, eNOS, and phospho-eNOS; equal protein loading was confirmed with β-actin. CD36 immunoprecipitation was probed for caveolin-1 to determine if CD36 and caveolin-1 were complexed on the cell membrane. NO was measured by fluorescence of ECs. RESULTS ILP caused a 227% increase in CD36 expression vs controls. Immunoprecipitation indicated a CD36/caveolin-1 complex on ECs' membrane with exposure to ILP. Dynamin-2 increased 52% and src-kinase-1 340% after ILP treatment vs control cells. eNOS phosphorylation was confirmed by a 63% increase in the phospho-eNOS/eNOS ratio in ILP-treated cells, and NO fluorescence increased 102%. CONCLUSION ILP enters ECs via endocytosis by a CD36/caveolin-1 cell membrane receptor complex, which in turn is pulled into the cell by dynamin-2 activity. Upregulation of src-kinase-1 and eNOS phosphorylation suggest downstream mediators. Subsequent NO release from ECs serve as a paracrine signal to neighboring cells for protection against IR injury. Student t-test was utilized for single comparisons and analysis of variance with Bonferroni-Dunn post hoc modification for multiple comparisons; P < .05 was considered statistically significant.
Collapse
|
23
|
Electronic Depth Adjustment in an Automatic Chest Compression Device for Rodents – Design and Implementation of a LabVIEW‐based Control Unit. FASEB J 2020. [DOI: 10.1096/fasebj.2020.34.s1.02768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
24
|
Simulated Stroke in a Mouse Neuronal Cell Culture Model. FASEB J 2020. [DOI: 10.1096/fasebj.2020.34.s1.01958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
25
|
Video laryngoscopic oral intubation in rats: a simple and effective method. Am J Physiol Lung Cell Mol Physiol 2020; 318:L1032-L1035. [PMID: 32233786 DOI: 10.1152/ajplung.00498.2019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Endotracheal intubation is a vital component of many rat in vivo experiments to secure the airway and allow controlled ventilation. Even in the hands of experienced researchers, however, the procedure remains technically challenging. The safest and most reliable way for human intubation is by video laryngoscopy. Previous attempts to apply this technique in rodents have been complicated and expensive. We, hereby, describe a novel, noninvasive method to safely intubate rats orally by video laryngoscopy, thus avoiding the need for a surgical tracheostomy. By repurposing a commercially available ear wax removal device, visualization of the rat larynx can be significantly enhanced. Because of its small diameter, integrated illumination, and a powerful camera with adequate focal length, the device has all of the necessary properties for exploring the upper airway of a rat. After identifying the vocal cords by video laryngoscopy, the insertion of an endotracheal tube (a 14G intravenous catheter) into the trachea under constant visual control is facilitated by using PE50 polyethylene tubing as a stylet (Seldinger technique). The procedure has been performed more than 60 times in our laboratory; all intubations were successful on the first attempt, and no adverse events were observed. We conclude that the described procedure is a simple and effective way to intubate a rat noninvasively, using inexpensive and commercially available equipment.
Collapse
|
26
|
Effect of High Glucose on Hypoxia/Reoxygenation Injury in Mouse Diabetic Coronary Artery Endothelial Cells. FASEB J 2020. [DOI: 10.1096/fasebj.2020.34.s1.03735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
27
|
PPARγ-Independent Side Effects of Thiazolidinediones on Mitochondrial Redox State in Rat Isolated Hearts. Cells 2020; 9:cells9010252. [PMID: 31968546 PMCID: PMC7017211 DOI: 10.3390/cells9010252] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 01/17/2020] [Accepted: 01/17/2020] [Indexed: 11/16/2022] Open
Abstract
The effect of anti-diabetic thiazolidinediones (TZDs) on contributing to heart failure and cardiac ischemia/reperfusion (IR) injury is controversial. In this study we investigated the effect of select TZDs on myocardial and mitochondrial function in Brown Norway rat isolated hearts. In a first set of experiments, the TZD rosiglitazone was given acutely before global myocardial IR, and pre- and post-IR function and infarct size were assessed. In a second set of experiments, different concentrations of rosiglitazone and pioglitazone were administered in the presence or absence of the specific PPARγ antagonist GW9662, and their effects on the mitochondrial redox state were measured by online NADH and FAD autofluorescence. The administration of rosiglitazone did not significantly affect myocardial function except for transiently increasing coronary flow, but it increased IR injury compared to the control hearts. Both TZDs resulted in dose-dependent, reversible increases in mitochondrial oxidation which was not attenuated by GW9662. Taken together, these data suggest that TZDs cause excessive mitochondrial uncoupling by a PPARγ-independent mechanism. Acute rosiglitazone administration before IR was associated with enhanced cardiac injury. If translated clinically, susceptible patients on PPARγ agonists may experience enhanced myocardial IR injury by mitochondrial dysfunction.
Collapse
|
28
|
Mechanical adjuncts for cardiocerebral resuscitation. Expert Rev Med Devices 2019; 16:771-776. [PMID: 31353970 DOI: 10.1080/17434440.2019.1649135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Introduction: Cardiac arrest remains a worldwide health problem with very poor outcome. In the absence of bystander resuscitation, survival rates decrease by 10% per minute of arrest and global ischemia. Even the best manual chest compressions, however, can only produce a fraction of normal cardiac output and blood flow to vital organs. Physiological principles and current evidence for the use of mechanical devices to increase survival and quality of life after cardiac arrest are highlighted in this review article. Areas covered: Mechanical adjuncts such as the Active Compression Decompression device, automated chest compressors and the use of a negative pressure valve (Impedance Threshold Device) can synergistically aid in improving quality of CPR and increasing cardiac output and vital organ perfusion. Expert opinion: The current conclusions that the use of mechanical adjunct devices in a preclinical setting is not recommended or neutral at best, need to be reevaluated, especially with regard to new advanced and promising treatments that require prolonged high-quality CPR during the transport to a hospital to improve the outcome of patients.
Collapse
|
29
|
|
30
|
Implementation of LabVIEW as a Virtual Instrument in a Cost‐Effective Isolated Lung Setup. FASEB J 2019. [DOI: 10.1096/fasebj.2019.33.1_supplement.846.9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
31
|
Accuracy of pH Measurements in Blood‐Free Balanced Salt Solutions with and without Bovine Serum Albumin—with Four Devices (ABL80, i‐STAT®, pH Paper, and pH Probe). FASEB J 2019. [DOI: 10.1096/fasebj.2019.33.1_supplement.544.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
32
|
Change over Time of Triphenyltetrazolium Measured Infarct Size in Rat Isolated Hearts. FASEB J 2019. [DOI: 10.1096/fasebj.2019.33.1_supplement.690.9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
33
|
DIY Video Laryngoscopy in Rats–Safe, Fast and Reliable. FASEB J 2019. [DOI: 10.1096/fasebj.2019.33.1_supplement.846.10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
34
|
DIY Isolated Lung Set‐up: Construction and Troubleshooting. FASEB J 2019. [DOI: 10.1096/fasebj.2019.33.1_supplement.550.7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
35
|
Model of Ischemia/Reperfusion Injury in Rat Brain Isolated Mitochondria. FASEB J 2019. [DOI: 10.1096/fasebj.2019.33.1_supplement.543.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
36
|
Modeling Ischemia/Reperfusion Injury in Rat Heart Isolated Mitochondria. FASEB J 2019. [DOI: 10.1096/fasebj.2019.33.1_supplement.543.2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
37
|
Suction-Assisted Laryngoscopy-Assisted Decontamination (SALAD) simulator for difficult airway management. TRENDS IN ANAESTHESIA AND CRITICAL CARE 2018. [DOI: 10.1016/j.tacc.2018.09.060] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
38
|
Total intravenous versus inhaled anesthesia in transsphenoidal tumor surgery. Am J Otolaryngol 2018; 39:567-569. [PMID: 30017373 PMCID: PMC6105509 DOI: 10.1016/j.amjoto.2018.06.018] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Accepted: 06/22/2018] [Indexed: 01/10/2023]
Abstract
PURPOSE Visualization of the surgical field is essential for patient safety during endoscopic transsphenoidal tumor surgery. In this retrospective chart review and data analysis of patients undergoing endoscopic transsphenoidal resection of pituitary tumors under general anesthesia we sought to determine if total intravenous anesthesia with propofol and remifentanil leads to decreased bleeding, surgical duration, time to extubation and/or length of stay in the recovery room compared to inhaled anesthesia with sevoflurane or desflurane. METHODS After IRB approval, chart reviews of 193 American Society of Anesthesiologists class 1 to 3 patients were conducted who had undergone transsphenoidal, endonasal resections of pituitary tumors under total intravenous or inhaled anesthesia at an academic teaching hospital in the United States over a seven-year time period. One hundred four patients fulfilled the inclusion criteria and were further reviewed. Primary outcome was intraoperative blood loss; secondary outcomes were surgical duration, time to extubation and length of stay in the recovery room. RESULTS Gender, age, and Lund-Mackay-Scores were equally distributed between the two anesthetic groups. We found no significant effect of the anesthetic technique, age, gender, or Lund Mackay score on any of the primary or secondary outcomes. The only significant predictor for recovery room length of stay was intraoperative blood loss. CONCLUSION Our study shows no evidence that total intravenous anesthesia is superior to inhaled anesthesia or vice versa during endoscopic transsphenoidal sinus surgery with regard to relevant clinical outcome parameters.
Collapse
|
39
|
Comparison of Different Mathematical Approaches to Assess Calcium Retention Capacity in Cardiac Isolated Mitochondria following Ischemia Reperfusion Injury. FASEB J 2018. [DOI: 10.1096/fasebj.2018.32.1_supplement.618.6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
40
|
Poloxamer 188 does not Target Altered Ca
2+
Channels in Cardiomyocytes during Hypoxia/Reoxygenation Injury. FASEB J 2018. [DOI: 10.1096/fasebj.2018.32.1_supplement.698.7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
41
|
Early Effects of Prolonged Cardiac Arrest and Ischemic Postconditioning during Cardiopulmonary Resuscitation on Cardiac and Brain Mitochondrial Function in Pigs. Resuscitation 2017; 116:8-15. [PMID: 28408349 PMCID: PMC5552370 DOI: 10.1016/j.resuscitation.2017.03.033] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Revised: 03/20/2017] [Accepted: 03/27/2017] [Indexed: 11/21/2022]
Abstract
BACKGROUND Out-of-hospital cardiac arrest (CA) is a prevalent medical crisis resulting in severe injury to the heart and brain and an overall survival of less than 10%. Mitochondrial dysfunction is predicted to be a key determinant of poor outcomes following prolonged CA. However, the onset and severity of mitochondrial dysfunction during CA and cardiopulmonary resuscitation (CPR) is not fully understood. Ischemic postconditioning (IPC), controlled pauses during the initiation of CPR, has been shown to improve cardiac function and neurologically favorable outcomes after 15min of CA. We tested the hypothesis that mitochondrial dysfunction develops during prolonged CA and can be rescued with IPC during CPR (IPC-CPR). METHODS A total of 63 swine were randomized to no ischemia (Naïve), 19min of ventricular fibrillation (VF) CA without CPR (Untreated VF), or 15min of CA with 4min of reperfusion with either standard CPR (S-CPR) or IPC-CPR. Mitochondria were isolated from the heart and brain to quantify respiration, rate of ATP synthesis, and calcium retention capacity (CRC). Reactive oxygen species (ROS) production was quantified from fresh frozen heart and brain tissue. RESULTS Compared to Naïve, Untreated VF induced cardiac and brain ROS overproduction concurrent with decreased mitochondrial respiratory coupling and CRC, as well as decreased cardiac ATP synthesis. Compared to Untreated VF, S-CPR attenuated brain ROS overproduction but had no other effect on mitochondrial function in the heart or brain. Compared to Untreated VF, IPC-CPR improved cardiac mitochondrial respiratory coupling and rate of ATP synthesis, and decreased ROS overproduction in the heart and brain. CONCLUSIONS Fifteen minutes of VF CA results in diminished mitochondrial respiration, ATP synthesis, CRC, and increased ROS production in the heart and brain. IPC-CPR attenuates cardiac mitochondrial dysfunction caused by prolonged VF CA after only 4min of reperfusion, suggesting that IPC-CPR is an effective intervention to reduce cardiac injury. However, reperfusion with both CPR methods had limited effect on mitochondrial function in the brain, emphasizing an important physiological divergence in post-arrest recovery between those two vital organs.
Collapse
|
42
|
Noninvasively Measured Hemoglobin Concentration Reflects Arterial Hemoglobin Concentration Before but Not After Cardiopulmonary Bypass in Patients Undergoing Coronary Artery or Valve Surgery. J Cardiothorac Vasc Anesth 2016; 30:1167-71. [PMID: 27475734 DOI: 10.1053/j.jvca.2016.03.148] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Indexed: 11/11/2022]
Abstract
OBJECTIVE This study compared noninvasively measured hemoglobin and arterial hemoglobin before and after cardiopulmonary bypass in patients undergoing coronary artery or valve surgery. DESIGN Observational study with retrospective data analysis. SETTING Veterans Affairs hospital. PARTICIPANTS Thirty-five men. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS Hemoglobin values were measured noninvasively by co-oximetry to corresponding arterial hemoglobin concentrations taken at clinically relevant time points chosen at the discretion of the cardiac anesthesiologist. Thirty-five and 27 pooled pairs of data were obtained before and after cardiopulmonary bypass, respectively. Arterial hemoglobin concentration was analyzed using i-STAT CG8+test cartridges routinely used in the authors' operating rooms and those of other institutions. Linear regression and Bland-Altman analysis revealed a significant positive bias, wide limits of agreement, and low correlation coefficients between the noninvasive and arterial hemoglobin measurements. These findings were especially notable after compared with before cardiopulmonary bypass. CONCLUSIONS The results suggested that noninvasive measurement of hemoglobin overestimates arterial hemoglobin by almost 1 g/dL when compared to iSTAT. A lack of precision also was observed with noninvasive measurement of hemoglobin, especially after cardiopulmonary bypass. These findings supported the contention that sole reliance on noninvasive measurement of hemoglobin for transfusion decisions in cardiac surgery patients may be inappropriate.
Collapse
|
43
|
|
44
|
|
45
|
Arterial flow waveforms, vascular tone, and chronic fatigue: a case report. Auton Neurosci 2015; 190:58-60. [PMID: 25817901 DOI: 10.1016/j.autneu.2015.03.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2014] [Revised: 02/09/2015] [Accepted: 03/17/2015] [Indexed: 11/19/2022]
Abstract
We present the case of a patient with chronic fatigue secondary to Postural Orthostatic Tachycardia Syndrome (POTS) who had distinctive abnormalities in his arterial waveform morphology as assessed by pulse oximetry. Moreover, the patient's arterial waveform changed markedly from being supine to upright, suggesting that arterial flow patterns may be abnormal in our patient. Analysis of the waveform suggested a positional hypovolemia as the cause of his orthostatic intolerance. We review general aspects of arterial flow waveform analysis pertinent to health care providers and discuss the pathophysiology of POTS.
Collapse
|
46
|
Non-invasive cardiac output monitoring during sinus surgery. J Anesth 2014; 29:639. [PMID: 25543335 DOI: 10.1007/s00540-014-1962-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2014] [Accepted: 12/06/2014] [Indexed: 11/29/2022]
|
47
|
Bundled postconditioning therapies improve hemodynamics and neurologic recovery after 17 min of untreated cardiac arrest. Resuscitation 2014; 87:7-13. [PMID: 25447036 DOI: 10.1016/j.resuscitation.2014.10.019] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2014] [Revised: 10/04/2014] [Accepted: 10/14/2014] [Indexed: 01/20/2023]
Abstract
OBJECTIVE Ischemic postconditioning (stutter CPR) and sevoflurane have been shown to mitigate the effects of reperfusion injury in cardiac tissue after 15min of ventricular fibrillation (VF) cardiac arrest. Poloxamer 188 (P188) has also proven beneficial to neuronal and cardiac tissue during reperfusion injury in human and animal models. We hypothesized that the use of stutter CPR, sevoflurane, and P188 combined with standard advanced life support would improve post-resuscitation cardiac and neurologic function after prolonged VF arrest. METHODS Following 17min of untreated VF, 20 pigs were randomized to Control treatment with active compression/decompression (ACD) CPR and impedance threshold device (ITD) (n=8) or Bundle therapy with stutter ACD CPR+ITD+sevoflurane+P188 (n=12). Epinephrine and post-resuscitation hypothermia were given in both groups per standard protocol. Animals that achieved return of spontaneous circulation (ROSC) were evaluated with echocardiography, biomarkers, and a blinded neurologic assessment with a cerebral performance category score. RESULTS Bundle therapy improved hemodynamics during resuscitation, reduced need for epinephrine and repeated defibrillation, reduced biomarkers of cardiac injury and end-organ dysfunction, and increased left ventricular ejection fraction compared to Controls. Bundle therapy also improved rates of ROSC (100% vs. 50%), freedom from major adverse events (50% vs. 0% at 48h), and neurologic function (42% with mild or no neurologic deficit and 17% achieving normal function at 48h). CONCLUSIONS Bundle therapy with a combination of stutter ACD CPR, ITD, sevoflurane, and P188 improved cardiac and neurologic function after 17min of untreated cardiac arrest in pigs. All studies were performed with approval from the Institutional Animal Care Committee of the Minneapolis Medical Research Foundation (protocol #12-11).
Collapse
|
48
|
Anaesthetic Postconditioning at the Initiation of CPR Improves Myocardial and Mitochondrial Function in a Pig Model of Prolonged Untreated Ventricular Fibrillation. Resuscitation 2014; 85:1745-51. [PMID: 25281906 DOI: 10.1016/j.resuscitation.2014.09.019] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2014] [Revised: 09/22/2014] [Accepted: 09/22/2014] [Indexed: 10/24/2022]
Abstract
BACKGROUND Anaesthetic postconditioning (APoC) attenuates myocardial injury following coronary ischaemia/reperfusion. We hypothesised that APoC at the initiation of cardiopulmonary resuscitation (CPR) will improve post resuscitation myocardial function along with improved mitochondrial function in a pig model of prolonged untreated ventricular fibrillation. METHODS In 32 pigs isoflurane anaesthesia was discontinued prior to induction of ventricular fibrillation that was left untreated for 15 min. At the initiation of CPR, 15 animals were randomised to controls (CON), and 17 to APoC with 2 vol% sevoflurane during the first 3 min CPR. Pigs were defibrillated after 4 min of CPR. After return of spontaneous circulation (ROSC), isoflurane was restarted at 0.8-1.5 vol% in both groups. Systolic and diastolic blood pressures were measured continuously. Of the animals that achieved ROSC, eight CON and eight APoC animals were randomised to have their left ventricular ejection fraction (LVEF%) assessed by echocardiography at 4h. Seven CON and nine APoC were randomised to euthanasia 15 min after ROSC to isolate mitochondria from the left ventricle for bioenergetic studies. RESULTS ROSC was achieved in 10/15 CON and 15/17 APoC animals. APoC improved haemodynamics during CPR and post-CPR LVEF%. Mitochondrial ATP synthesis, coupling of oxidative phosphorylation and calcium retention capacity were improved in cardiac mitochondria isolated after APoC. CONCLUSIONS In a porcine model of prolonged untreated cardiac arrest, APoC with inhaled sevoflurane at the initiation of CPR, is associated with preserved mitochondrial function and improved post resuscitation myocardial dysfunction. Approved by the Institutional Animal Care Committee of the Minneapolis Medical Research Foundation of Hennepin County Medical Center (protocol number 11-05).
Collapse
|
49
|
Malignant hyperthermia crisis: optimizing patient outcomes through simulation and interdisciplinary collaboration. AORN J 2014; 99:301-8; quiz 309-11. [PMID: 24472592 DOI: 10.1016/j.aorn.2013.06.012] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2012] [Revised: 05/10/2013] [Accepted: 06/14/2013] [Indexed: 11/26/2022]
Abstract
Malignant hyperthermia (MH) is a rare, life-threatening event. Many clinicians are unprepared to manage an MH crisis in the perioperative setting because it requires the use of low-frequency, high-risk skills and procedures. Simulation is a recognized educational method for cumulative and integrative learning in a safe environment that resembles real-life clinical scenarios. The aim of this quality improvement project was to provide simulation-based learning to perioperative personnel to educate them in the early recognition, treatment, and management of MH. An interdisciplinary team developed an MH education plan. Implementation of the plan involved a two-part training: an educational session, and a role-playing scenario using high-fidelity OR simulation. Simulation teaching provided OR personnel with an opportunity for skill development, teamwork, interdisciplinary communication, and problem solving. Personnel responded favorably and identified positive outcomes, such as role clarity, improved anticipatory response, and overall team cohesion. In addition, the project included updating the MH cart and writing the hospital's MH policy.
Collapse
|
50
|
Far red/near infrared light-induced protection against cardiac ischemia and reperfusion injury remains intact under diabetic conditions and is independent of nitric oxide synthase. Front Physiol 2014; 5:305. [PMID: 25202275 PMCID: PMC4141548 DOI: 10.3389/fphys.2014.00305] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2014] [Accepted: 07/26/2014] [Indexed: 12/27/2022] Open
Abstract
Far red/near-infrared light (NIR) promotes a wide range of biological effects including tissue protection but whether and how NIR is capable of acutely protecting myocardium against ischemia and reperfusion injury in vivo is not fully elucidated. Our previous work indicates that NIR exposure immediately before and during early reperfusion protects the myocardium against infarction through mechanisms that are nitric oxide (NO)-dependent. Here we tested the hypothesis that NIR elicits protection in a diabetic mouse model where other cardioprotective interventions such as pre- and postconditioning fail, and that the protection is independent of nitric oxide synthase (NOS). NIR reduced infarct size dose dependently. Importantly, NIR-induced protection was preserved in a diabetic mouse model (db/db) and during acute hyperglycemia, as well as in endothelial NOS(-/-) mice and in wild type mice treated with NOS inhibitor L-NAME. In in vitro experiments NIR light liberates NO from nitrosyl hemoglobin (HbNO) and nitrosyl myoglobin (MbNO) in a wavelength-(660-830 nm) and dose-dependent manner. Irradiation at 660 nm yields the highest release of NO, while at longer wavelengths a dramatic decrease of NO release can be observed. Similar wavelength dependence was observed for the protection of mice against cardiac ischemia and reperfusion injury in vivo. NIR-induced NO release from deoxymyoglobin in the presence of nitrite mildly inhibits respiration of isolated mitochondria after hypoxia. In summary, NIR applied during reperfusion protects the myocardium against infarction in an NO-dependent, but NOS-independent mechanisms, whereby mitochondria may be a target of NO released by NIR, leading to reduced reactive oxygen species generation during reperfusion. This unique mechanism preserves protection even during diabetes where other protective strategies fail.
Collapse
|