1
|
Raman Spectroscopy of Disperse Systems with Varying Particle Sizes and Correction of Signal Losses. SENSORS (BASEL, SWITZERLAND) 2024; 24:3132. [PMID: 38793986 PMCID: PMC11125269 DOI: 10.3390/s24103132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 05/06/2024] [Accepted: 05/13/2024] [Indexed: 05/26/2024]
Abstract
In this paper, a dispersion of glass beads of different sizes in an ammonium nitrate solution is investigated with the aid of Raman spectroscopy. The signal losses caused by the dispersion are quantified by an additional scattered light measurement and used to correct the measured ammonium nitrate concentration. Each individual glass bead represents an interface at which the excitation laser is deflected from its direction causing distortion in the received Raman signal. It is shown that the scattering losses measured with the scattered light probe correlate with the loss of the Raman signal, which means that the data obtained can be used to correct the measured values. The resulting correction function considers different particle sizes in the range of 2-99 µm as well as ammonium nitrate concentrations of 0-20 wt% and delivers an RMSEP of 1.952 wt%. This correction provides easier process access to dispersions that were previously difficult or impossible to measure.
Collapse
|
2
|
Raman Spectroscopy of Glass Beads in Ammonium Nitrate Solution and Compensation of Signal Losses. SENSORS (BASEL, SWITZERLAND) 2024; 24:314. [PMID: 38257407 PMCID: PMC10819147 DOI: 10.3390/s24020314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 12/28/2023] [Accepted: 01/04/2024] [Indexed: 01/24/2024]
Abstract
In the present study, the influence of disperse systems on Raman scattering was investigated. How an increasing particle concentration weakens the quantitative signal of the Raman spectrum is shown. Furthermore, the change in the position of the optimal measurement point in the fluid was considered in detail. Additional transmission measurements can be used to derive a simple and robust correction method that allows the actual concentration of the continuous phase to be determined with a standard deviation of 2.6%.
Collapse
|
3
|
Liquid Mixing on Falling Films: Marker-Free, Molecule-Sensitive 3D Mapping Using Raman Imaging. SENSORS (BASEL, SWITZERLAND) 2023; 23:5846. [PMID: 37447696 DOI: 10.3390/s23135846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 06/15/2023] [Accepted: 06/20/2023] [Indexed: 07/15/2023]
Abstract
Following up on a proof of concept, this publication presents a new method for mixing mapping on falling liquid films. On falling liquid films, different surfaces, plain or structured, are common. Regarding mixing of different components, the surface has a significant effect on its capabilities and performance. The presented approach combines marker-free and molecule-sensitive measurements with cross-section mapping to emphasize the mixing capabilities of different surfaces. As an example of the mixing capabilities on falling films, the mixing of sodium sulfate with tap water is presented, followed by a comparison between a plain surface and a pillow plate. The method relies upon point-by-point Raman imaging with a custom-built high-working-distance, low-depth-of-focus probe. To compensate for the long-time measurements, the continuous plant is in its steady state, which means the local mixing state is constant, and the differences are based on the liquids' position on the falling film, not on time. Starting with two separate streams, the mixing progresses by falling down the surface. In conclusion, Raman imaging is capable of monitoring mixing without any film disturbance and provides detailed information on liquid flow in falling films.
Collapse
|
4
|
Spatial Omics Imaging of Fresh-Frozen Tissue and Routine FFPE Histopathology of a Single Cancer Needle Core Biopsy: A Freezing Device and Multimodal Workflow. Cancers (Basel) 2023; 15:2676. [PMID: 37345020 DOI: 10.3390/cancers15102676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2023] [Revised: 04/16/2023] [Accepted: 05/06/2023] [Indexed: 06/23/2023] Open
Abstract
The complex molecular alterations that underlie cancer pathophysiology are studied in depth with omics methods using bulk tissue extracts. For spatially resolved tissue diagnostics using needle biopsy cores, however, histopathological analysis using stained FFPE tissue and the immunohistochemistry (IHC) of a few marker proteins is currently the main clinical focus. Today, spatial omics imaging using MSI or IRI is an emerging diagnostic technology for the identification and classification of various cancer types. However, to conserve tissue-specific metabolomic states, fast, reliable, and precise methods for the preparation of fresh-frozen (FF) tissue sections are crucial. Such methods are often incompatible with clinical practice, since spatial metabolomics and the routine histopathology of needle biopsies currently require two biopsies for FF and FFPE sampling, respectively. Therefore, we developed a device and corresponding laboratory and computational workflows for the multimodal spatial omics analysis of fresh-frozen, longitudinally sectioned needle biopsies to accompany standard FFPE histopathology of the same biopsy core. As a proof-of-concept, we analyzed surgical human liver cancer specimens using IRI and MSI with precise co-registration and, following FFPE processing, by sequential clinical pathology analysis of the same biopsy core. This workflow allowed for a spatial comparison between different spectral profiles and alterations in tissue histology, as well as a direct comparison for histological diagnosis without the need for an extra biopsy.
Collapse
|
5
|
Establishing Reliable Research Data Management by Integrating Measurement Devices Utilizing Intelligent Digital Twins. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23010468. [PMID: 36617065 PMCID: PMC9824845 DOI: 10.3390/s23010468] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 12/28/2022] [Accepted: 12/28/2022] [Indexed: 06/01/2023]
Abstract
One of the main topics within research activities is the management of research data. Large amounts of data acquired by heterogeneous scientific devices, sensor systems, measuring equipment, and experimental setups have to be processed and ideally be managed by Findable, Accessible, Interoperable, and Reusable (FAIR) data management approaches in order to preserve their intrinsic value to researchers throughout the entire data lifecycle. The symbiosis of heterogeneous measuring devices, FAIR principles, and digital twin technologies is considered to be ideally suited to realize the foundation of reliable, sustainable, and open research data management. This paper contributes a novel architectural approach for gathering and managing research data aligned with the FAIR principles. A reference implementation as well as a subsequent proof of concept is given, leveraging the utilization of digital twins to overcome common data management issues at equipment-intense research institutes. To facilitate implementation, a top-level knowledge graph has been developed to convey metadata from research devices along with the produced data. In addition, a reactive digital twin implementation of a specific measurement device was devised to facilitate reconfigurability and minimized design effort.
Collapse
|
6
|
Film Thickness and Glycerol Concentration Mapping of Falling Films Based on Fluorescence and Near-Infrared Technique. MICROMACHINES 2022; 13:2184. [PMID: 36557483 PMCID: PMC9785223 DOI: 10.3390/mi13122184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Revised: 12/06/2022] [Accepted: 12/07/2022] [Indexed: 06/17/2023]
Abstract
Falling film evaporation processes involve high fluid velocities with continuous variations in local film thickness, fluid composition, and viscosity. This contribution presents a parallel and complementary film thickness and concentration mapping distribution in falling films using a non-invasive fluorescence and near-infrared imaging technique. The experiments were performed with a mixture of glycerol/water with a mass fraction from 0 to 0.65 gglycgtotal-1 and operating ranges similar to evaporation processes. The measurement system was designed by integrating two optical measurement methods for experimental image analysis. The film thickness was evaluated using a VIS camera and high-power LEDs at 470 nm. The local glycerol concentration gglycgtotal-1 was determined using a NIR camera and high-power LEDs at 1050, 1300, 1450 and 1550 nm. A multiwavelength analysis with all NIR wavelengths was implemented with a better correlation for falling films at low flow velocity. The results show an improvement in the analysis of falling films with high flow velocities up to almost 500 mm/s by using only the 1450 nm wavelength and the fluorescence measurement. Simultaneous imaging analysis of film thickness and concentration in falling films provides further insight into understanding mass and heat transport and thus supports the optimization of falling film evaporators.
Collapse
|
7
|
New Conceptional Study of a Portable Highly Sensitive Photometric Raman Sensor. SENSORS (BASEL, SWITZERLAND) 2022; 22:6098. [PMID: 36015859 PMCID: PMC9416093 DOI: 10.3390/s22166098] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 08/10/2022] [Accepted: 08/12/2022] [Indexed: 06/15/2023]
Abstract
Quality control and reaction monitoring are necessary to ensure the consistency of any kind of mixing or reaction process. In this context, a novel portable high-sensitivity sensor prototype based on the Raman effect is presented in this study. The elongated probe head is designed for (but not limited to) monitoring high temperature batch processes for quality assurance. Thanks to the highly sensitive special detectors, concentration differences of up to 50 mmol/L can currently be detected, which facilitates compliance with high product quality standards. In addition, seamless reaction tracking is possible. Small individual adjustments through simple, intuitive mechanical components provide a high degree of flexibility in reaction selection by the end user. Specially developed software automates the evaluation process and gives the user visual signals about the current status and progress of the batch as well as an emergency stop if temperature limits could damage individual components. By using all the individual components developed, the problem of the limited integration times of previous spectrometric measuring instruments could be reduced. The prototype was validated using concentration measurements of various substances that occur as standard in batch processes. In addition, this article provides an outlook on the fact that Raman measurements can also be carried out successfully and reliably in explosive environments in the future with the prototype presented.
Collapse
|
8
|
Marker-Free, Molecule Sensitive Mapping of Disturbed Falling Fluid Films Using Raman Imaging. SENSORS 2022; 22:s22114086. [PMID: 35684704 PMCID: PMC9185504 DOI: 10.3390/s22114086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 05/24/2022] [Accepted: 05/26/2022] [Indexed: 12/10/2022]
Abstract
Technical liquid flow films are the basic arrangement for gas fluid transitions of all kinds and are the basis of many chemical processes, such as columns, evaporators, dryers, and different other kinds of fluid/fluid separation units. This publication presents a new method for molecule sensitive, non-contact, and marker-free localized concentration mapping in vertical falling films. Using Raman spectroscopy, no label or marker is needed for the detection of the local composition in liquid mixtures. In the presented cases, the film mapping of sodium sulfate in water on a plain surface as well as an added artificial streaming disruptor with the shape of a small pyramid is scanned in three dimensions. The results show, as a prove of concept, a clear detectable spectroscopic difference between air, back plate, and sodium sulfate for every local point in all three dimensions. In conclusion, contactless Raman scanning on falling films for liquid mapping is realizable without any mechanical film interaction caused by the measuring probe. Surface gloss or optical reflections from a metallic back plate are suppressed by using only inelastic light scattering and the mathematical removal of background noise.
Collapse
|
9
|
|
10
|
Visualization of Local Concentration and Viscosity Distribution during Glycerol-Water Mixing in a Y-Shape Minichannel: A Proof-of-Concept-Study. MICROMACHINES 2021; 12:mi12080940. [PMID: 34442562 PMCID: PMC8401092 DOI: 10.3390/mi12080940] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Revised: 08/06/2021] [Accepted: 08/07/2021] [Indexed: 01/21/2023]
Abstract
The work presents an efficient and non-invasive method to visualize the local concentration and viscosity distribution of two miscible and non-reacting substances with a significant viscosity difference in a microchannel with a Y-shape cell. The proof-of-concept setup consists of a near-infrared (NIR) camera and cost-effective dome lighting with NIR light-emitting diodes (LED) covering the wavelength range of 1050 to 1650 nm. Absorption differences of glycerol and water and their mixtures with a mass fraction of glycerol from 0 to 0.95 gGlycgtotal-1 were analyzed in the NIR spectral area. The resulting measurement images were converted in a concentration profile by using absorbance calculated with Lambert-Beer law. A linear behavior between the concentration and the absorption coefficient is demonstrated. The result of local concentration in mass fraction was used to determine the local viscosity and illustrated as distribution images. By variating the fluid parameters, the influences of the highly different original viscosities in the mixing procedure were investigated and visualized.
Collapse
|
11
|
Incremental Learning in Modelling Process Analysis Technology (PAT)-An Important Tool in the Measuring and Control Circuit on the Way to the Smart Factory. SENSORS 2021; 21:s21093144. [PMID: 34062767 PMCID: PMC8124399 DOI: 10.3390/s21093144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 04/15/2021] [Accepted: 04/28/2021] [Indexed: 12/01/2022]
Abstract
To meet the demands of the chemical and pharmaceutical process industry for a combination of high measurement accuracy, product selectivity, and low cost of ownership, the existing measurement and evaluation methods have to be further developed. This paper demonstrates the attempt to combine future Raman photometers with promising evaluation methods. As part of the investigations presented here, a new and easy-to-use evaluation method based on a self-learning algorithm is presented. This method can be applied to various measurement methods and is carried out here using an example of a Raman spectrometer system and an alcohol-water mixture as demonstration fluid. The spectra’s chosen bands can be later transformed to low priced and even more robust Raman photometers. The evaluation method gives more precise results than the evaluation through classical methods like one primarily used in the software package Unscrambler. This technique increases the accuracy of detection and proves the concept of Raman process monitoring for determining concentrations. In the example of alcohol/water, the computation time is less, and it can be applied to continuous column monitoring.
Collapse
|
12
|
Feasibility Study for a Chemical Process Particle Size Characterization System for Explosive Environments Using Low Laser Power. MICROMACHINES 2020; 11:mi11100911. [PMID: 33008003 PMCID: PMC7600193 DOI: 10.3390/mi11100911] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 09/25/2020] [Accepted: 09/28/2020] [Indexed: 11/16/2022]
Abstract
The industrial particle sensor market lacks simple, easy to use, low cost yet robust, safe and fast response solutions. Towards development of such a sensor, for in-line use in micro channels under continuous flow conditions, this work introduces static light scattering (SLS) determination of particle diameter using a laser with an emission power of less than 5 µW together with sensitive detectors with detection times of 1 ms. The measurements for the feasibility studies are made in an angular range between 20° and 160° in 2° increments. We focus on the range between 300 and 1000 nm, for applications in the production of paints, colors, pigments and crystallites. Due to the fast response time, reaction characteristics in microchannel designs for precipitation and crystallization processes can be studied. A novel method for particle diameter characterization is developed using the positions of maxima and minima and slope distribution. The novel algorithm to classify particle diameter is especially developed to be independent of dispersed phase concentration or concentration fluctuations like product flares or signal instability. Measurement signals are post processed and particle diameters are validated against Mie light scattering simulations. The design of a low cost instrument for industrial use is proposed.
Collapse
|
13
|
Recent Advances in Experimental Techniques for Flow and Mass Transfer Analyses in Thermal Separation Systems. CHEM-ING-TECH 2020. [DOI: 10.1002/cite.202000076] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
14
|
Photometric Inline Monitoring of Pigment Concentration in Highly Filled Lacquers. CHEM-ING-TECH 2020. [DOI: 10.1002/cite.201900186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
15
|
Contrast enhancement of surface layers with fast middle-infrared scanning. Heliyon 2019; 5:e02442. [PMID: 31528751 PMCID: PMC6742858 DOI: 10.1016/j.heliyon.2019.e02442] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2019] [Revised: 07/19/2019] [Accepted: 09/04/2019] [Indexed: 11/16/2022] Open
Abstract
In this study, we present an efficient and innovative method to visualize absorption differences in the mid-infrared range with spatial resolution using laser technology. We focus on only two lasers with wavelengths between 3.4 μm and 3.6 μm and a spatial resolution of 20 μm and thus achieve a scanning speed up to 300 kS/s for fast image generation. In this article, we focus especially on the detection of C–H bands in this region of the absorption spectrum. Concealed structures are examined by calculating the measured structures with both wavelengths. In our results, we demonstrate exemplary measurements on 130-μm-thick polyvinyl chloride layers. In turn, these structures are suitable for further processing in rapid quantitative quality control.
Collapse
|
16
|
Experimentelle Untersuchung einer Dampfstrahlkälteanlage mit einem alternativen Treibmedium. CHEM-ING-TECH 2019. [DOI: 10.1002/cite.201900020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
17
|
|
18
|
Untersuchung von lokalen Schichtdickenverteilungen in Fluiden mithilfe der Nahinfrarot‐Bildanalyse. CHEM-ING-TECH 2019. [DOI: 10.1002/cite.201800106] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
19
|
Schnelle lokale Raman‐Messung zur Untersuchung von Konzentrationsprofilen bei Mischvorgängen in Mikrokanälen. CHEM-ING-TECH 2019. [DOI: 10.1002/cite.201800105] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
20
|
High moisture extrusion of wheat gluten: Modeling of the polymerization behavior in the screw section of the extrusion process. J FOOD ENG 2019. [DOI: 10.1016/j.jfoodeng.2018.10.031] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
21
|
Hydrolytischer Faulschlammaufschluss durch Direktdampfeinspeisung. CHEM-ING-TECH 2019. [DOI: 10.1002/cite.201800001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
22
|
Noncontact recognition of fluorescently labeled objects in deep tissue via a novel optical light beam arrangement. PLoS One 2018; 13:e0208236. [PMID: 30566459 PMCID: PMC6300195 DOI: 10.1371/journal.pone.0208236] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2018] [Accepted: 11/14/2018] [Indexed: 12/30/2022] Open
Abstract
To date, few optical imaging systems are available in clinical practice to perform noninvasive measurements transcutaneously. Instead, functional imaging is performed using ionizing radiation or intense magnetic fields in most cases. The applicability of fluorescence imaging (e.g., for the detection of fluorescently labeled objects, such as tumors) is limited due to the restricted tissue penetration of light and the required long exposure time. Thus, the development of highly sensitive and easily manageable instruments is necessary to broaden the utility of optical imaging. To advance these developments, an improved fluorescence imaging system was designed in this study that operates on the principle of noncontact laser-induced fluorescence and enables the detection of fluorescence from deeper tissue layers as well as real-time imaging. The high performance of the developed optical laser scanner results from the combination of specific point illumination, an intensified charge-coupled device (ICCD) detector with a novel light trap, and a filtering strategy. The suitability of the laser scanner was demonstrated in two representative applications and an in vivo evaluation. In addition, a comparison with a planar imaging system was performed. The results show that the exposure time with the developed laser scanner can be reduced to a few milliseconds during measurements with a penetration depth of up to 32 mm. Due to these short exposure times, real-time fluorescence imaging can be easily achieved. The ability to measure fluorescence from deep tissue layers enables clinically relevant applications, such as the detection of fluorescently labeled malignant tumors.
Collapse
|
23
|
Entwicklung eines Partikelmesssystems zur Erfassung geringer Streulicht‐Intensitäten optimiert für den Einsatz sehr schwacher Laserstrahlen. CHEM-ING-TECH 2018. [DOI: 10.1002/cite.201800073] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
24
|
Vergleich dreier Latentwärmespeicherkonzepte zur effizienten Nutzung von Niedertemperaturwärme. CHEM-ING-TECH 2018. [DOI: 10.1002/cite.201800015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
25
|
Near-Infrared Image Analysis as Tool for Monitoring Process Activities. CHEMBIOENG REVIEWS 2018. [DOI: 10.1002/cben.201800013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
26
|
|
27
|
Gastrin-Releasing Peptide Receptor- and Prostate-Specific Membrane Antigen-Specific Ultrasmall Gold Nanoparticles for Characterization and Diagnosis of Prostate Carcinoma via Fluorescence Imaging. Bioconjug Chem 2018. [PMID: 29542916 DOI: 10.1021/acs.bioconjchem.8b00067] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Gold nanoparticles (AuNPs) have widely been used for 70 years in cancer treatment, but only in the last 15 years has the focus been on specific AuNPs with homogeneous size and shape for various areas in science. They constitute a perfect platform for multifunctionalization and therefore enable the enhancement of target affinity. Here we report on the development of tumor specific AuNPs as diagnostic tools intended for the detection of prostate cancer via fluorescence imaging and positron emission tomography (PET). The AuNPs were further evaluated in vitro and in vivo and exhibited favorable diagnostic properties concerning tumor cell uptake, biodistribution, clearance, and tumor retention.
Collapse
|
28
|
|
29
|
Highly Sensitive Raman Spectroscopy with Low Laser Power for Fast In-Line Reaction and Multiphase Flow Monitoring. Anal Chem 2016; 88:9368-9374. [DOI: 10.1021/acs.analchem.6b01509] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
30
|
Einfluss des Nährmediums auf die Bewegungscharakteristik von Bacillus amyloliquefaciens. CHEM-ING-TECH 2016. [DOI: 10.1002/cite.201500090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
31
|
Measurement of the true melt temperature in a twin-screw extrusion processing of starch based matrices via infrared sensor. J FOOD ENG 2016. [DOI: 10.1016/j.jfoodeng.2015.09.018] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
32
|
Fast and Efficient Acquisition of Kinetic Data in Microreactors Using In-Line Raman Analysis. Org Process Res Dev 2015. [DOI: 10.1021/acs.oprd.5b00184] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
33
|
Single bacteria movement tracking by online microscopy--a proof of concept study. PLoS One 2015; 10:e0122531. [PMID: 25849813 PMCID: PMC4388530 DOI: 10.1371/journal.pone.0122531] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2014] [Accepted: 02/18/2015] [Indexed: 11/19/2022] Open
Abstract
In this technical report we demonstrate a low-cost online unit allowing movement tracking of flagellated bacteria on a single-cell level during fermentation processes. The system's ability to distinguish different metabolic states (viability) of bacteria by movement velocity was investigated. A flow-through cuvette with automatically adjustable layer thickness was developed. The cuvette can be used with most commercially available laboratory microscopes equipped with 40× amplification and a digital camera. In addition, an automated sample preparation unit and a software module was developed measuring size, moved distance, and speed of bacteria. In a proof of principle study the movement velocities of Bacillus amyloliquefaciens FZB42 during three batch fermentation processes were investigated. In this process the bacteria went through different metabolic states, vegetative growth, diauxic shift, vegetative growth after diauxic shift, and sporulation. It was shown that the movement velocities during the different metabolic states significantly differ from each other. Therefore, the described setup has the potential to be used as a bacteria viability monitoring tool. In contrast to some other techniques, such as electro-optical techniques, this method can even be used in turbid production media.
Collapse
|
34
|
Experimentelle und theoretische Analyse der dominierenden Wärmetransportmechanismen einer rollenden Kugel auf einer Platte. CHEM-ING-TECH 2014. [DOI: 10.1002/cite.201450488] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
35
|
Incremental learning with SVM for multimodal classification of prostatic adenocarcinoma. PLoS One 2014; 9:e93600. [PMID: 24699716 PMCID: PMC3974761 DOI: 10.1371/journal.pone.0093600] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2013] [Accepted: 03/06/2014] [Indexed: 11/18/2022] Open
Abstract
Robust detection of prostatic cancer is a challenge due to the multitude of variants and their representation in MR images. We propose a pattern recognition system with an incremental learning ensemble algorithm using support vector machines (SVM) tackling this problem employing multimodal MR images and a texture-based information strategy. The proposed system integrates anatomic, texture, and functional features. The data set was preprocessed using B-Spline interpolation, bias field correction and intensity standardization. First- and second-order angular independent statistical approaches and rotation invariant local phase quantization (RI-LPQ) were utilized to quantify texture information. An incremental learning ensemble SVM was implemented to suit working conditions in medical applications and to improve effectiveness and robustness of the system. The probability estimation of cancer structures was calculated using SVM and the corresponding optimization was carried out with a heuristic method together with a 3-fold cross-validation methodology. We achieved an average sensitivity of 0.844 ± 0.068 and a specificity of 0.780 ± 0.038, which yielded superior or similar performance to current state of the art using a total database of only 41 slices from twelve patients with histological confirmed information, including cancerous, unhealthy non-cancerous and healthy prostate tissue. Our results show the feasibility of an ensemble SVM being able to learn additional information from new data while preserving previously acquired knowledge and preventing unlearning. The use of texture descriptors provides more salient discriminative patterns than the functional information used. Furthermore, the system improves selection of information, efficiency and robustness of the classification. The generated probability map enables radiologists to have a lower variability in diagnosis, decrease false negative rates and reduce the time to recognize and delineate structures in the prostate.
Collapse
|
36
|
Inline-Partikelmesssystem für fallende Granulate. CHEM-ING-TECH 2014. [DOI: 10.1002/cite.201300094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
37
|
Real-time GPU-based ultrasound simulation using deformable mesh models. IEEE TRANSACTIONS ON MEDICAL IMAGING 2013; 32:609-618. [PMID: 23268382 DOI: 10.1109/tmi.2012.2234474] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
This paper presents a real-time capable graphics processing unit (GPU)-based ultrasound simulator suitable for medical education. The main focus of the simulator is to synthesize realistic looking ultrasound images in real-time including artifacts, which are essential for the interpretation of this data. The simulation is based on a convolution-enhanced ray-tracing approach and uses a deformable mesh model. Deformations of the mesh model are calculated using the PhysX engine. Our method advances the state of the art for real-time capable ultrasound simulators by following the path of the ultrasound pulse, which enables better simulation of ultrasound-specific artifacts. An evaluation of our proposed method in comparison with recent generative slicing-based strategies as well as real ultrasound images is performed. Hereby, a gelatin ultrasound phantom containing syringes filled with different media is scanned with a real transducer. The obtained images are then compared to images which are simulated using a slicing-based technique and our proposed method. The particular benefit of our method is the accurate simulation of ultrasound-specific artifacts, like range distortion, refraction and acoustic shadowing. Several test scenarios are evaluated regarding simulation time, to show the performance and the bottleneck of our method. While being computationally more intensive than slicing techniques, our simulator is able to produce high-quality images in real-time, tracing over 5000 rays through mesh models with more than 2 000 000 triangles of which up to 200 000 may be deformed each frame.
Collapse
|
38
|
Estimation of skin phototypes with optical parameters: an experimental study using newly developed fibre optic detection device. Int J Cosmet Sci 2012; 35:50-6. [DOI: 10.1111/ics.12003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2012] [Accepted: 08/26/2012] [Indexed: 11/29/2022]
|
39
|
Determination of alcohol and extract concentration in beer samples using a combined method of near-infrared (NIR) spectroscopy and refractometry. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2010; 58:12634-12641. [PMID: 21090679 DOI: 10.1021/jf1030604] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A new approach of combination of near-infrared (NIR) spectroscopy and refractometry was developed in this work to determine the concentration of alcohol and real extract in various beer samples. A partial least-squares (PLS) regression, as multivariate calibration method, was used to evaluate the correlation between the data of spectroscopy/refractometry and alcohol/extract concentration. This multivariate combination of spectroscopy and refractometry enhanced the precision in the determination of alcohol, compared to single spectroscopy measurements, due to the effect of high extract concentration on the spectral data, especially of nonalcoholic beer samples. For NIR calibration, two mathematical pretreatments (first-order derivation and linear baseline correction) were applied to eliminate light scattering effects. A sample grouping of the refractometry data was also applied to increase the accuracy of the determined concentration. The root mean squared errors of validation (RMSEV) of the validation process concerning alcohol and extract concentration were 0.23 Mas% (method A), 0.12 Mas% (method B), and 0.19 Mas% (method C) and 0.11 Mas% (method A), 0.11 Mas% (method B), and 0.11 Mas% (method C), respectively.
Collapse
|
40
|
|
41
|
|
42
|
58. Die Bedeutung von Sensoren bei der Prozeßführung. CHEM-ING-TECH 1993. [DOI: 10.1002/cite.330650960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
43
|
Partikelmeßtechnik: Status - Trend - Bedarf. CHEM-ING-TECH 1992. [DOI: 10.1002/cite.3306409102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
44
|
Nuclear-excited Feshbach resonances in the electron scattering from hydrogen halides. PHYSICAL REVIEW LETTERS 1989; 62:1735-1737. [PMID: 10039754 DOI: 10.1103/physrevlett.62.1735] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
|
45
|
|