1
|
A novel 3D MRI-based approach for assessing supraspinatus muscle length. J Biomech 2024; 168:112110. [PMID: 38677025 DOI: 10.1016/j.jbiomech.2024.112110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 02/22/2024] [Accepted: 04/16/2024] [Indexed: 04/29/2024]
Abstract
Rotator cuff (RC) tears are a common source of pain and decreased shoulder strength. Muscle length is known to affect muscle strength, and therefore evaluating changes in supraspinatus muscle length associated with RC pathology, surgical repair, and post-operative recovery may provide insights into functional deficits. Our objective was to develop a reliable MRI-based approach for assessing supraspinatus muscle length. Using a new semi-automated approach for identifying 3D location of the muscle-tendon junction (MTJ), supraspinatus muscle length was calculated as the sum of MTJ distance (distance between 3D MTJ position and glenoid plane) and supraspinatus fossa length (distance between root of the scapular spine and glenoid plane). Inter- and intra-operator reliability of this technique were assessed with intraclass correlation coefficient (ICC) and found to be excellent (ICCs > 0.96). Muscle lengths of 6 patients were determined before RC repair surgery and at 3- and 12-months post-surgery. Changes in normalized muscle length (muscle length as a percentage of pre-surgical muscle length) at 3 months post-surgery varied considerably across patients (16.1 % increase to 7.0 % decrease) but decreased in all patients from 3- to 12-months post-surgery (0.3 % to 17.2 %). This study developed a novel and reliable approach for quantifying supraspinatus muscle length and provided preliminary demonstration of its utility by assessing muscle length changes associated with RC pathology and surgical repair. Future studies can use this technique to evaluate changes over time in supraspinatus muscle length in response to clinical intervention, and associations between muscle length and shoulder function.
Collapse
|
2
|
Investigating the multifactorial etiology of supraspinatus tendon tears. J Orthop Res 2024; 42:578-587. [PMID: 37814893 DOI: 10.1002/jor.25699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 05/23/2023] [Accepted: 10/05/2023] [Indexed: 10/11/2023]
Abstract
The purpose of this study was to develop a multivariable model to determine the extent to which a combination of etiological factors is associated with supraspinatus tendon tears. Fifty-four asymptomatic individuals (55 ± 4 years) underwent testing of their dominant shoulder. Diagnostic ultrasound was used to assess for a supraspinatus tendon tear. The etiological factors investigated included demographics (age and sex), tendon impingement during shoulder motion (via biplane videoradiography), glenohumeral morphology (via computed tomography imaging), family history of a tear (via self-report), occupational shoulder exposure (via shoulder job exposure matrix), and athletic exposure (via self-report). Univariate relationships between etiological predictors and supraspinatus tears were assessed using logistic regression and odds ratios (ORs), while multivariable relationships were assessed using classification and regression tree analysis. Thirteen participants (24.1%) had evidence of a supraspinatus tear. Individuals with a tear had a higher critical shoulder angle (OR 1.2, p = 0.028) and acromial index (OR 1.2, p = 0.016) than individuals without a tear. The multivariable model suggested that a tear in this cohort can be explained with acceptable accuracy (AUROC = 0.731) by the interaction between acromial index and shoulder occupational exposure: a tear is more likely in individuals with a high acromial index (p < 0.001), and in individuals with a low acromial index and high occupational exposure (p < 0.001). The combination of an individual's glenohumeral morphology (acromial index) and occupational shoulder exposure may be important in the development of supraspinatus tears.
Collapse
|
3
|
In vivo evaluation of rotator cuff internal impingement during scapular plane abduction in asymptomatic individuals. J Orthop Res 2023; 41:718-726. [PMID: 35880416 PMCID: PMC9877247 DOI: 10.1002/jor.25423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 06/17/2022] [Accepted: 07/23/2022] [Indexed: 02/04/2023]
Abstract
Internal impingement-or entrapment of the undersurface of the rotator cuff tendon against the glenoid during overhead activities-is believed to contribute to articular-sided tears. However, little is known about internal impingement outside athletic populations. Therefore, the objectives of this study were to (1) describe glenoid-to-footprint distances and proximity centers during dynamic, in vivo motion in asymptomatic individuals, and (2) determine the extent to which these measures differed between individuals with and without a rotator cuff tear. Shoulder kinematics were assessed in 37 asymptomatic individuals during scapular plane abduction using a high-speed biplane radiographic system. Glenoid-to-footprint distances and proximity center locations were calculated by combining the kinematics with computerized tomography-derived bone models. Glenoid-to-footprint contact was presumed to occur when the minimum distance was less than the estimated labral thickness. The condition of the supraspinatus tendon (intact, torn) was assessed using ultrasound. Minimum distances and proximity centers were compared over humerothoracic elevation angles (90°, 110°, 130°, 150°) and between supraspinatus pathology groups using two-factor mixed model analysis of variances. Glenoid-to-footprint minimum distances decreased consistently across elevation angles (p < 0.01) without a significant difference between groups. Contact was estimated to occur in all participants. Proximity centers were generally located on the anterior half of the rotator cuff footprint and on the posterosuperior glenoid. Statement of Clinical Significance: Internal impingement during overhead motions may be a prevalent mechanism of rotator cuff pathology as contact appears to be common and involves the region of the rotator cuff footprint where degenerative rotator cuff tears are thought to originate.
Collapse
|
4
|
Correspondence between scapular anatomical coordinate systems and the 3D axis of motion: A new perspective on an old challenge. J Biomech 2022; 145:111385. [PMID: 36403529 PMCID: PMC10321460 DOI: 10.1016/j.jbiomech.2022.111385] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 10/14/2022] [Accepted: 11/09/2022] [Indexed: 11/16/2022]
Abstract
Several scapular anatomical coordinate systems have been reported in the literature to describe shoulder kinematics. Unfortunately, the use of different conventions hinders comparison across studies. Further, inconsistencies between a coordinate system and the scapula's 3D axis of motion means that scapular motion will be incorrectly attributed to axes about which it did not rotate. The objectives of this study were to: 1) determine the extent to which the axes of four common scapular coordinate system conventions correspond to the 3D axis of scapular motion (i.e., instantaneous helical axis, IHA), and 2) report the prevalence of scapulothoracic gimbal lock for each convention. Shoulder kinematics were tracked during scapular plane abduction in 45 participants using biplane videoradiography. Scapulothoracic kinematics were described using the original convention proposed by van der Helm, the convention recommended by the International Society of Biomechanics (ISB), a glenoid-based coordinate system, and a glenoid-oriented coordinate system. The 3D angle was calculated between the IHA and each axis of the four conventions (IHA-axis angular deviations). A repeated measures ANOVA was used to compare IHA-axis angular deviations between conventions. The glenoid-oriented and ISB conventions resulted in the smallest and largest IHA-axis angular deviations, respectively (21.7°±3.6° vs. 30.5°±5.2°, p < 0.01). Gimbal lock was approached in 17.8% of participants when using the original convention, 2.2% when using the ISB convention, and 0% when using the glenoid-based or -oriented conventions. These findings suggest the glenoid-oriented coordinate system may be worthy of further consideration when investigating shoulder kinematics during scapular plane abduction.
Collapse
|
5
|
Intervertebral kinematics during neck motion 6.5 years after fusion and artificial disc replacement. Clin Biomech (Bristol, Avon) 2022; 99:105756. [PMID: 36063742 DOI: 10.1016/j.clinbiomech.2022.105756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 08/24/2022] [Accepted: 08/26/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND Arthroplasty with artificial disc replacement for surgical treatment of cervical spine degeneration was introduced with the notion that motion-preserving approaches would prevent development of adjacent segment disease. Though clinical outcomes favor arthroplasty over the commonly used anterior cervical discectomy with fusion approach, clinical studies confirming the biomechanical basis of these results are lacking. The aim of this study was to compare intervertebral kinematics between arthroplasty and fusion patients 6.5 years post-surgery during physiological motion of the neck. METHODS Using a biplane dynamic X-ray system, computed tomography imaging and model based tracking algorithms, three dimensional intervertebral kinematics were measured during neck axial rotation and extension in 14 patients treated for cervical radiculopathy with fusion (n = 8) or arthroplasty (n = 6). The measurements were performed at 2-year (baseline) and 6.5 year post-surgical time points, with the main interest being in the interaction between surgery types and time points. 3 translations and 3 rotations were investigated for the index (C5C6), and upper- (C4C5) and lower adjacent levels (C6C7). FINDINGS Surgery-time interaction was significant for axial rotation (P < 0.04) and flexion-extension rotation (P < 0.005) in C4C5 during neck axial rotation, left-right translation (P < 0.04) in C5C6 and anterior-posterior translation in C6C7 (P < 0.04) during neck extension. In contrast with the expectations, axial rotation and flexion-extension decreased in C4C5 during neck rotation and anterior-posterior translation decreased in C6C7 during neck extension for fusion. INTERPRETATION The findings do not support the notion that adjacent segment motion increases after fusion.
Collapse
|
6
|
Validation of a 3D CT imaging method for quantifying implant migration following anatomic total shoulder arthroplasty. J Orthop Res 2022; 40:1270-1280. [PMID: 34436796 DOI: 10.1002/jor.25170] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 06/29/2021] [Accepted: 07/30/2021] [Indexed: 02/04/2023]
Abstract
Glenoid component loosening remains a common complication following anatomic total shoulder arthroplasty (TSA); however, plain radiographs are unable to accurately detect early implant migration. The purpose of this study was to validate the accuracy of a method of postoperative, three-dimensional (3D) computed tomography (CT) imaging with metal artifact reduction (MAR) to detect glenoid component migration following anatomic TSA. Tantalum bead markers were inserted into polyethylene glenoid components for implant detection on 3D CT. In-vitro validation was performed using a glenoid component placed into a scapula sawbone and incrementally translated and rotated, with MAR 3D CT acquired at each test position. Accuracy was evaluated by root mean square error (RMSE). In-vivo validation was performed on six patients who underwent anatomic TSA, with two postoperative CT scans acquired in each patient and marker-based radiostereometric analysis (RSA) performed on the same days. Glenoid component migration was calculated relative to a scapular coordinate system for both MAR 3D CT and RSA. Accuracy was evaluated by RMSE and paired Student's t-tests. The largest RMSE on in-vitro testing was 0.24 mm in translation and 0.11° in rotation, and on in-vivo testing was 0.47 mm in translation and 1.04° in rotation. There were no significant differences between MAR 3D CT and RSA measurement methods. MAR 3D CT imaging is capable of quantifying glenoid component migration with a high level of accuracy. MAR 3D CT imaging is advantageous over RSA because it is readily available clinically and can also be used to evaluate the implant-bone interface.
Collapse
|
7
|
Quantifying shoulder activity after rotator cuff repair: Technique and preliminary results. J Orthop Res 2022; 40:917-924. [PMID: 34191325 DOI: 10.1002/jor.25122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 04/13/2021] [Accepted: 06/25/2021] [Indexed: 02/04/2023]
Abstract
Repair tissue healing after rotator cuff repair remains a significant clinical problem, and excessive shoulder activity after surgical repair is believed to contribute to re-tears. In contrast, small animal studies have demonstrated that complete removal of activity impairs tendon healing and have advocated for an "appropriate" level of activity, but in humans the appropriate amount of shoulder activity to enhance healing is not known. As an initial step toward understanding the relationship between postoperative shoulder activity and repair tissue healing, the objectives of this study were to assess the precision, accuracy, and feasibility of a wrist-worn triaxial accelerometer for measuring shoulder activity. Following assessments of precision (±0.002 g) and accuracy (±0.006 g), feasibility was assessed by measuring 1 week of shoulder activity in 14 rotator cuff repair patients and 8 control subjects. Shoulder activity was reported in terms of volume (mean acceleration, activity count, mean activity index, active time) and intensity (intensity gradient). Patients had significantly less volume (p ≤ .03) and intensity (p = .01) than controls. Time post-surgery was significantly associated with the volume (p ≤ .05 for mean acceleration, activity count, and mean activity index) and intensity (p = .03) of shoulder activity, but not active time (p = .08). These findings indicate this approach has the accuracy and precision necessary to continuously monitor shoulder activity with a wrist-worn sensor. The preliminary data demonstrate the ability to discriminate between healthy control subjects and patients recovering from rotator cuff repair and provide support for using a wearable sensor to monitor changes over time in shoulder activity.
Collapse
|
8
|
In Vivo Static Retraction and Dynamic Elongation of Rotator Cuff Repair Tissue After Surgical Repair: A Preliminary Analysis at 3 Months. Orthop J Sports Med 2022; 10:23259671221084294. [PMID: 35387360 PMCID: PMC8978322 DOI: 10.1177/23259671221084294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 12/23/2021] [Indexed: 11/17/2022] Open
Abstract
Background: Rotator cuff repair is a common orthopaedic procedure that provides pain relief for many patients, but unfortunately, an estimated 20% to 70% of repair procedures will fail. Previous research has shown that elongation (ie, retraction) of a repaired tendon is common even in patients with a repair construct that appears intact on magnetic resonance imaging. However, it is unknown how this repair tissue functions under dynamic conditions. Purpose: To quantify static retraction and maximum dynamic elongation of repair tissue after rotator cuff repair. Study Design: Case series; Level of evidence, 4. Methods: Data from 9 patients were analyzed for this study. During surgery, a 3.1-mm tantalum bead was sutured to the supraspinatus tendon, medial to the repair site. Glenohumeral kinematics were assessed at 1 week (static) and 3 months (static and during scapular-plane abduction) after surgery using a biplanar videoradiographic system. The 3-dimensional position of the bead was calculated relative to the tendon’s insertion on the humerus (ie, bead-to-insertion distance). Static retraction was calculated as the change in the bead-to-insertion distance under static conditions between 1 week and 3 months after surgery, and maximum dynamic elongation was calculated as the maximal positive change in the bead-to-insertion distance during dynamic motion relative to the start of motion. The magnitudes of static retraction and maximum dynamic elongation were assessed with 1-sample t tests. Results: At 3 months after surgery, static retraction occurred in all patients by a mean of 10.0 ± 9.1 mm (P = .01 compared with no elongation). During scapular-plane abduction, maximum dynamic elongation averaged 1.4 ± 1.0 mm (P < .01 compared with no elongation). Descriptively, dynamic elongation consistently took 1 of 2 forms: an initial increase in the bead-to-insertion distance (mean, 2.0 ± 0.6 mm) before decreasing until the end of motion or an immediate and substantial decrease in the bead-to-insertion distance at the onset of motion. Conclusion: Repair tissue elongation (static retraction and maximum dynamic elongation) appeared to be a common and significant finding at 3 months after arthroscopic rotator cuff repair. Dynamic elongation of repair tissue during scapular-plane abduction exhibited 1 of 2 distinct patterns, which may suggest different patterns of supraspinatus mechanical and neuromuscular function.
Collapse
|
9
|
Presurgical tear characteristics and estimated shear modulus as predictors of repair integrity and shoulder function one year after rotator cuff repair. JSES Int 2021; 6:62-69. [PMID: 35141678 PMCID: PMC8811389 DOI: 10.1016/j.jseint.2021.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Background Rotator cuff repair provides pain relief for many patients; however, retears are relatively common and affect approximately 20%-70% of patients after repair. Although magnetic resonance imaging (MRI) offers the ability to assess tissue characteristics such as tear size, retraction, and fatty infiltration, it provides little insight into the quality of the musculotendinous tissues the surgeon will encounter during surgery. However, shear wave elastography (SWE) could provide an indirect assessment of quality (ie, stiffness) by measuring the speed of shear waves propagating through tissue. The objective of this study was to determine the extent to which estimated shear modulus predicts repair integrity and functional outcomes 1 year after rotator cuff repair. Methods Thirty-three individuals scheduled to undergo arthroscopic rotator cuff repair were enrolled in this study. Before surgery, shear modulus of the supraspinatus tendon and muscle was estimated using ultrasound SWE. MRIs were obtained before and 1 year after surgery to assess tear characteristics and repair integrity, respectively. Shoulder strength, range of motion, and patient-reported pain and function were assessed before and after surgery. Functional outcomes were compared between groups and across time using a two-factor mixed model analysis of variance. Stepwise regression with model comparison was used to investigate the extent to which MRI and shear modulus predicted repair integrity and function at 1 year after surgery. Results At 1 year after surgery, 56.5% of patients had an intact repair. No significant differences were found in any demographic variable, presurgical tear characteristic, or shear modulus between patients with an intact repair and those with a recurrent tear. Compared with presurgical measures, patients in both groups demonstrated significant improvements at 1 year after surgery in pain (P < .01), self-reported function (P < .01), range of motion (P < .01), and shoulder strength (P < .01). In addition, neither presurgical MRI variables (P > .16) nor shear modulus (P > .52) was significantly different between groups at 1 year after surgery. Finally, presurgical shear modulus generally did not improve the prediction of functional outcomes above and beyond that provided by MRI variables alone (P > .22). Conclusion Although SWE remains a promising modality for many clinical applications, this study found that SWE-estimated shear modulus did not predict repair integrity or functional outcomes at 1 year after surgery, nor did it add to the prediction of outcomes above and beyond that provided by traditional presurgical MRI measures of tear characteristics. Therefore, it appears that further research is needed to fully understand the clinical utility of SWE for musculoskeletal tissue and its potential use for predicting outcomes after surgical rotator cuff repair.
Collapse
|
10
|
Abstract
The shoulder is one of the human body's most complex joint systems, with motion occurring through the coordinated actions of four individual joints, multiple ligaments, and approximately 20 muscles. Unfortunately, shoulder pathologies (e.g., rotator cuff tears, joint dislocations, arthritis) are common, resulting in substantial pain, disability, and decreased quality of life. The specific etiology for many of these pathologic conditions is not fully understood, but it is generally accepted that shoulder pathology is often associated with altered joint motion. Unfortunately, measuring shoulder motion with the necessary level of accuracy to investigate motion-based hypotheses is not trivial. However, radiographic-based motion measurement techniques have provided the advancement necessary to investigate motion-based hypotheses and provide a mechanistic understanding of shoulder function. Thus, the purpose of this article is to describe the approaches for measuring shoulder motion using a custom biplanar videoradiography system. The specific objectives of this article are to describe the protocols to acquire biplanar videoradiographic images of the shoulder complex, acquire CT scans, develop 3D bone models, locate anatomical landmarks, track the position and orientation of the humerus, scapula, and torso from the biplanar radiographic images, and calculate the kinematic outcome measures. In addition, the article will describe special considerations unique to the shoulder when measuring joint kinematics using this approach.
Collapse
|
11
|
Ultrasound shear wave elastography and its association with rotator cuff tear characteristics. JSES Int 2021; 5:500-506. [PMID: 34136861 PMCID: PMC8178591 DOI: 10.1016/j.jseint.2020.11.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
Background Approximately 20-60% of rotator cuff repairs fail with higher failure rates in patients with larger or more chronic tears. Although MRI provides an objective estimate of tear size, it can only provide qualitative descriptions of tear chronicity. By contrast, ultrasound shear wave elastography (SWE) may assess tear chronicity by estimating tissue mechanical properties (ie, shear modulus). Furthermore, SWE imaging does not share many of the challenges associated with MRI (eg, high cost, risk of claustrophobia). Therefore, the objective of this study was to determine the extent to which estimated supraspinatus shear modulus is associated with conventional MRI-based measures of rotator cuff tear size and chronicity. Methods Shear modulus was estimated using ultrasound SWE in two regions of the supraspinatus (intramuscular tendon, muscle belly) under two contractile conditions (passive, active) in 22 participants with full-thickness rotator cuff tears. The extent to which estimated supraspinatus shear modulus is associated with conventional MRI measures of tear size and chronicity was assessed using correlation coefficients and Kruskal-Wallis tests, as appropriate. Results Estimated shear modulus was not significantly associated with anterior/posterior tear size (P > .09), tear retraction (P > .20), occupation ratio (P > .11), or fatty infiltration (P > .30) under any testing condition. Discussion Although ultrasound SWE measurements have been shown to be altered in the presence of various tendinopathies, the findings of this study suggest the utility of ultrasound SWE in this population (ie, patients with a small to medium supraspinatus rotator cuff tear) before surgical rotator cuff repair remains unclear.
Collapse
|
12
|
Instantaneous helical axis estimation of glenohumeral kinematics: The impact of rotator cuff pathology. J Biomech 2020; 109:109924. [PMID: 32807327 PMCID: PMC7443981 DOI: 10.1016/j.jbiomech.2020.109924] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Revised: 05/02/2020] [Accepted: 06/21/2020] [Indexed: 11/16/2022]
Abstract
The rotator cuff is theorized to contribute to force couples required to produce glenohumeral kinematics. Impairment in these force couples would theoretically result in impaired ball-and-socket kinematics. Although less frequently used than traditional kinematic descriptors (e.g., Euler angles, joint translations), helical axes are capable of identifying alterations in ball-and-socket kinematics by quantifying the variability (i.e., dispersion) in axis orientation and position during motion. Consequently, assessing glenohumeral helical dispersion may provide indirect evidence of rotator cuff function. The purpose of this exploratory study was to determine the extent to which rotator cuff pathology is associated with alterations in ball-and-socket kinematics. Fifty-one participants were classified into one of five groups based on an assessment of the supraspinatus using diagnostic imaging: asymptomatic healthy, asymptomatic tendinosis, asymptomatic partial-thickness tear, asymptomatic full-thickness tear, symptomatic full-thickness tear. Glenohumeral kinematics were quantified during coronal plane abduction using a biplane x-ray system and described using instantaneous helical axes. The degree to which glenohumeral motion coincided with ball-and-socket kinematics was described using the angular and positional dispersion about the optimal helical axis and pivot, respectively. No statistically significant difference was observed between groups in angular dispersion. However, symptomatic individuals with a full-thickness supraspinatus tear had significantly more positional dispersion than asymptomatic individuals with a healthy supraspinatus or tendinosis. These findings suggest that symptomatic individuals with a full-thickness supraspinatus tear exhibit impaired ball-and-socket kinematics, which is believed to be associated with a disruption of the glenohumeral force couples.
Collapse
|
13
|
Dynamic foraminal dimensions during neck motion 6.5 years after fusion and artificial disc replacement. PLoS One 2020; 15:e0237350. [PMID: 32780779 PMCID: PMC7418980 DOI: 10.1371/journal.pone.0237350] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 07/23/2020] [Indexed: 12/26/2022] Open
Abstract
Objective To compare changes in foraminal motion at two time points post-surgery between artificial disc replacement (ADR) and anterior cervical discectomy and fusion (ACDF). Methods Eight ACDF and 6 ADR patients (all single-level C5-6) were tested at 2 years (T1) and 6.5 years (T2) post-surgery. The minimum foraminal height (FH.Min) and width (FW.Min) achieved during neck axial rotation and extension, and the range of these dimensions during motion (FH.Rn and FW.Rn, respectively) were measured using a biplane dynamic x-ray system, CT imaging and model-based tracking while patients performed neck axial rotation and extension tasks. Two-way mixed ANOVA was employed for analysis. Results In neck extension, significant interactions were found between year post-surgery and type of surgery for FW.Rn at C5-6 (p<0.006) and C6-7 (p<0.005), and for FH.Rn at C6-7 (p<0.01). Post-hoc analysis indicated decreases over time in FW.Rn for ACDF (p<0.01) and increases in FH.Rn for ADR (p<0.03) at the C6-7 adjacent level. At index level, FW.Rn was comparable between ACDF and ADR at T1, but was smaller for ACDF than for ADR at T2 (p<0.002). In axial rotation, differences were found between T1 and T2 but did not depend on type of surgery (p>0.7). Conclusions Changes were observed in the range of foraminal geometry at adjacent levels from 2 years to 6.5 years post-surgery that were different between ACDF and ADR for neck extension. These changes are contrary to the notion that motion at adjacent levels continue to increase following ACDF as compared to ADR over the long term.
Collapse
|
14
|
Three-dimensional scapular morphology is associated with rotator cuff tears and alters the abduction moment arm of the supraspinatus. Clin Biomech (Bristol, Avon) 2020; 78:105091. [PMID: 32580097 PMCID: PMC8161464 DOI: 10.1016/j.clinbiomech.2020.105091] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 04/29/2020] [Accepted: 06/09/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND Numerous studies have reported an association between rotator cuff injury and two-dimensional measures of scapular morphology. However, the mechanical underpinnings explaining how these shape features affect glenohumeral joint function and lead to injury are poorly understood. We hypothesized that three-dimensional features of scapular morphology differentiate asymptomatic shoulders from those with rotator cuff tears, and that these features would alter the mechanical advantage of the supraspinatus. METHODS Twenty-four individuals with supraspinatus tears and twenty-seven age-matched controls were recruited. A statistical shape analysis identified scapular features distinguishing symptomatic patients from asymptomatic controls. We examined the effect of injury-associated morphology on mechanics by developing a morphable model driven by six degree-of-freedom biplanar videoradiography data. We used the model to simulate abduction for a range of shapes and computed the supraspinatus moment arm. FINDINGS Rotator cuff injury was associated with a cranial orientation of the glenoid and scapular spine (P = .011, d = 0.75) and/or decreased subacromial space (P = .001, d = 0.94). The shape analysis also identified previously undocumented features associated with superior inclination and subacromial narrowing. In our computational model, warping the scapula from a cranial to a lateral orientation increased the supraspinatus moment arm at 20° of abduction and decreased the moment arm at 160° of abduction. INTERPRETATIONS Three-dimensional analysis of scapular morphology indicates a stronger relationship between morphology and cuff tears than two-dimensional measures. Insight into how morphological features affect rotator cuff mechanics may improve patient-specific strategies for prevention and treatment of cuff tears.
Collapse
|
15
|
Correlation of neural foraminal motion after surgical treatment of cervical radiculopathy with long-term patient reported outcomes. JOURNAL OF SPINE SURGERY 2020; 6:18-25. [PMID: 32309642 DOI: 10.21037/jss.2020.03.02] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background Post-surgical changes in adjacent segment motion are considered a factor in further development of degeneration and cervical radiculopathy. The objective was to examine the extent of correlations between physiological motion of cervical foramina and long-term patient reported outcomes (PRO). Methods Biplane X-ray imaging and CT-based markerless tracking were used to measure 3D static and dynamic dimensions during neck axial rotation and extension from 18 patients treated for C5-6 radiculopathy with fusion or arthroplasty. Minimum foraminal height (FH.Min) and width (FW.Min), and their range (FH.Range and FW.Range) achieved during a motion task were calculated for adjacent levels (C4-5 and C6-7) at 2.0±0.6 years post-surgery. The modified Japanese Orthopedic Association score (mJOAS), the Neck Disability Index (NDI) including the visual analogue scale (VAS) for neck and arm pain, and the EuroQol EQ-5D score were recorded at 6.5±1.1 years post-surgery. The relationships between 6.5-year outcomes and 2-year foraminal motion were examined using regression. Results Worsening patient-reported outcomes were generally associated with lower values of FW.Min (P<0.05 to P<0.008), the associations being stronger for neck extension (r2 up to 0.43). Dynamic foraminal measurements from the C6-7 level more significantly and consistently correlated with mJOAS, EQ-5D and NDI Arm Pain VAS (r2=0.27 to 0.43; P<0.03 to P<0.008), whereas those from the C4-5 level correlated with NDI Neck Pain VAS (r2=0.33; P<0.02). Conclusions Dynamic 3D foraminal dimensions at 2-year post-surgery, notably FW.Min measured in neck extension at adjacent levels, were associated with PRO at 6.5 years post-surgery. These relationships provide insight into the motion related factors in development of pain and loss of function, and may help develop markers or objective outcome measures.
Collapse
|
16
|
Abstract
BACKGROUND Short leg casts (SLCs) and fracture boots are used to treat foot and ankle injuries, but the decision to use one device over the other is often subjective. This study compared the impact of SLCs and low and high fracture boots on ankle motion and offloading. METHODS Twenty healthy adults were prospectively studied. High-speed dynamic radiography was utilized to determine tibiotalar range of motion in the sagittal plane during nonweightbearing (NWB) and weightbearing (WB) gait in a shoe (control), SLC, and low and high fracture boots. Sensors captured peak plantar surface forces to determine ankle offloading. RESULTS In NWB, the low fracture boot (2.2 ± 2.0 degrees), high fracture boot (2.3 ± 1.6 degrees), and SLC (2.3 ± 1.5 degrees) had significantly less motion compared with the control (3.6 ± 2.1 degrees; P ≤ .026). During WB, the SLC (3.4 ± 1.4 degrees) and high fracture boot (4.8 ± 2.0 degrees) had less motion compared with the low fracture boot (7.8 ± 3.4 degrees; P < .001). Finally, the SLC (172.6% ± 48.3% body weight [BW]) and low fracture (165.1% ± 36.2% BW) and high fracture (154.5% ± 32.9% BW) boots were associated with less peak plantar surface force compared with the control (195.0% ± 43.8% BW; P ≤ .087). CONCLUSION The SLC and high fracture boot immobilized the ankle in NWB and offloaded and immobilized the ankle in WB. The low fracture boot also immobilized the ankle in NWB, but in WB, the low fracture boot only offloaded the ankle and did not immobilize it. CLINICAL RELEVANCE The low fracture boot may be more suited for NWB or possibly immobilizing the foot in WB.
Collapse
|
17
|
Abstract
Asymptomatic rotator cuff tears (RCTs) are prevalent in the general population; they are positively associated with age and are common in the contralateral shoulder of individuals who are being treated for shoulder pain or a symptomatic RCT. Asymptomatic RCTs are likely to become symptomatic over time, corresponding with decreased patient-reported function, strength, and range of motion. Previous studies have largely reported inconsistent findings regarding patient-reported outcomes, strength, range of motion, and kinematics in individuals with asymptomatic RCTs. Future research would benefit from characterizing any functional alteration that is associated with asymptomatic rotator cuff pathology, including determining whether such alterations are detrimental or compensatory and understanding the mechanism by which an asymptomatic RCT becomes symptomatic.
Collapse
|
18
|
Shear wave elastography of the healing human patellar tendon following ACL reconstruction. Knee 2019; 26:347-354. [PMID: 30638680 DOI: 10.1016/j.knee.2018.12.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Revised: 12/14/2018] [Accepted: 12/16/2018] [Indexed: 02/02/2023]
Abstract
PURPOSE Anterior cruciate ligament (ACL) ruptures are common and are frequently reconstructed using a patellar tendon (PT) autograft. Unfortunately, the time course of PT healing after ACL reconstruction is not particularly well understood. Thus, the primary objective of this study was to use shear wave elastography (SWE) to evaluate the extent to which shear wave speed (SWS) is associated with time after ACL reconstruction. METHODS Longitudinal SWE images were acquired from lateral, central, and medial regions of the PT from two groups: 30 patients who had undergone ACL reconstruction with a PT autograft within the preceding 40 months, and 30 age-matched asymptomatic control subjects. SWE images were acquired at 20° and 90° of passive flexion from both knees. In each subject group, statistical analyses assessed changes in mean SWS with time post-surgery, as well as differences in mean SWS between PT regions and limbs. RESULTS In the ACL reconstruction patients, mean SWS increased with time post-surgery in the lateral region of the involved knee (p = 0.025) and decreased with time post-surgery in the central region of the contralateral knee (p = 0.022). CONCLUSION The findings suggest that there is an association between the mechanical properties of the PT and time post-surgery in both the involved and contralateral limbs after ACL reconstruction. These changes are likely due to maturation of the donor site tissue and changes in gait/loading patterns following ACL rupture and reconstruction. LEVEL OF EVIDENCE Level II - Prospective Cohort.
Collapse
|
19
|
Clinical utilization of shear wave elastography in the musculoskeletal system. Ultrasonography 2018; 38:2-12. [PMID: 30343557 PMCID: PMC6323314 DOI: 10.14366/usg.18039] [Citation(s) in RCA: 70] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Accepted: 08/23/2018] [Indexed: 01/02/2023] Open
Abstract
Shear wave elastography (SWE) is an emerging technology that provides information about the inherent elasticity of tissues by producing an acoustic radiofrequency force impulse, sometimes called an "acoustic wind," which generates transversely-oriented shear waves that propagate through the surrounding tissue and provide biomechanical information about tissue quality. Although SWE has the potential to revolutionize bone and joint imaging, its clinical application has been hindered by technical and artifactual challenges. Many of the stumbling blocks encountered during musculoskeletal SWE imaging are readily recognizable and can be overcome, but progressive advances in technology and a better understanding of image acquisition are required before SWE can reliably be used in musculoskeletal imaging.
Collapse
|
20
|
Dynamic foraminal dimensions during neck extension and rotation in fusion and artificial disc replacement: an observational study. Spine J 2018; 18:575-583. [PMID: 28882520 DOI: 10.1016/j.spinee.2017.08.248] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2017] [Revised: 07/25/2017] [Accepted: 08/21/2017] [Indexed: 02/03/2023]
Abstract
BACKGROUND Changes in the dimensions of the cervical neural foramina (CNF) are considered to be a key factor in nerve root compression and development of cervical radiculopathy. However, to what extent foraminal geometry differs between patients who underwent anterior cervical discectomy and fusion (ACDF) and those who underwent total disc arthroplasty with an artificial disc (AD) during physiological motion is largely unknown. PURPOSE The objective of this study is to compare CNF dimensions during physiological neck motion between ACDF and AD. STUDY DESIGN/SETTING This is a retrospective comparative analysis of prospectively collected, consecutive, non-randomized series of patients at a single institution. PATIENT SAMPLE A total of 16 single-level C5-C6 ACDF (4 males, 12 females; 28-71 years) and 7 single-level C5-C6 cervical arthroplasty patients (3 males, 4 females; 38-57 years), at least 12 months after surgery (23.6±6.8 months) were included. OUTCOME MEASURES Patient demographics, preoperative magnetic resonance imaging (MRI)-based measurements of cervical spine degeneration, and 2-year postoperative measurements of dynamic foraminal geometry were the outcome measures. METHODS Biplane X-ray images were acquired during axial neck rotation and neck extension. A computed tomography scan was also acquired from C3 to the first thoracic vertebrae. The subaxial cervical vertebrae (C3-C7) were reconstructed into three-dimensional (3D) bone models for use with model-based tracking. Foraminal height (FH) was calculated as the 3D distance between the superior point of the inferior pedicle and the inferior point of the superior pedicle using custom software. Foraminal width (FW) was similarly calculated as the 3D distance between the anterolateral aspect of the superior vertebral body inferior notch and the posterolateral aspect of the inferior vertebral body superior notch. Dynamic foraminal dimensions were quantified as the minimum (FH.Min, FW.Min), the range (FH.Range, FW.Range), and the median (FH.Med, FW.Med) of each trial and then averaged over trials. Mixed model analysis of variance framework was used to examine the differences between ACDF and AD groups. The initial severity of disc degeneration as determined from preoperative MRI images was introduced as covariates in the models. RESULTS At the operated level (C5-C6), FH.Med and FH.Range were smaller in ACDF than in AD during axial rotation and neck extension (p<.003 to p<.05). At the superior adjacent level (C4-C5), no significant difference was found. At the inferior adjacent level (C6-C7), FW.Range was greater in ACDF than in AD during axial rotation and extension (p<.05). At the non-adjacent level (C3-C4), FW.Range was greater in ACDF than in AD during extension (p<.008). CONCLUSIONS This study demonstrated decreases in foraminal dimensions and their range for ACDF compared with AD at the operated level. In contrast, it demonstrated increases in the range of foraminal dimensions during motion for ACDF compared with AD at the non-operated segments. Together, these data support the notion that increased mobility at the non-operated segments after ACDF may contribute to a greater risk for adjacent segment degeneration. Because of the significant presence of range variables in the findings, the current data also indicate that a dynamic evaluation is likely more appropriate for evaluation of the differences in foramina between ACDF and AD than a static evaluation.
Collapse
|
21
|
Effects of age and pathology on shear wave speed of the human rotator cuff. J Orthop Res 2018; 36:282-288. [PMID: 28657192 PMCID: PMC7050544 DOI: 10.1002/jor.23641] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2017] [Accepted: 06/25/2017] [Indexed: 02/04/2023]
Abstract
Rotator cuff tears are common and often repaired surgically, but post-operative repair tissue healing, and shoulder function can be unpredictable. Tear chronicity is believed to influence clinical outcomes, but conventional clinical approaches for assessing tear chronicity are subjective. Shear wave elastography (SWE) is a promising technique for assessing soft tissue via estimates of shear wave speed (SWS), but this technique has not been used extensively on the rotator cuff. Specifically, the effects of age and pathology on rotator cuff SWS are not well known. The objectives of this study were to assess the association between SWS and age in healthy, asymptomatic subjects, and to compare measures of SWS between patients with a rotator cuff tear and healthy, asymptomatic subjects. SWE images of the supraspinatus muscle and intramuscular tendon were acquired from 19 asymptomatic subjects and 11 patients with a rotator cuff tear. Images were acquired with the supraspinatus under passive and active (i.e., minimal activation) conditions. Mean SWS was positively associated with age in the supraspinatus muscle and tendon under passive and active conditions (p ≤ 0.049). Compared to asymptomatic subjects, patients had a lower mean SWS in their muscle and tendon under active conditions (p ≤ 0.024), but no differences were detected under passive conditions (p ≥ 0.783). These findings identify the influences of age and pathology on SWS in the rotator cuff. These preliminary findings are an important step toward evaluating the clinical utility of SWE for assessing rotator cuff pathology. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:282-288, 2018.
Collapse
|
22
|
Abstract
BACKGROUND Shoulder injuries are common among competitive swimmers, and the progression of shoulder pathology is not well understood. The objective of this study was to assess the extent to which years of competitive swim training were associated with physical properties of the supraspinatus muscle and tendon, shoulder strength, and self-reported assessments of shoulder pain and function. HYPOTHESIS Increasing years of competition will be associated with declining physical properties of the supraspinatus muscle/tendon and declining self-reported assessments of pain and function. STUDY DESIGN Descriptive epidemiology study. LEVEL OF EVIDENCE Level 4. METHODS After institutional approval, 18 collegiate female swimmers enrolled in the study. For each swimmer, supraspinatus tendon thickness was measured; tendinosis was assessed using ultrasound imaging, supraspinatus muscle shear wave velocity was assessed using shear wave elastography, isometric shoulder strength was measured using a Biodex system, and self-reported assessments of pain/function were assessed using the Western Ontario Rotator Cuff (WORC) score. All subjects were tested before the start of the collegiate swim season. Linear regression was used to assess the association between years of competition and the outcome measures. RESULTS Years of participation was positively associated with tendon thickness ( P = 0.01) and negatively associated with shear wave velocity ( P = 0.04) and WORC score ( P < 0.01). Shoulder strength was not associated with years of participation ( P > 0.39). CONCLUSION Long-term competitive swim training is associated with declining measures of supraspinatus muscle/tendon properties and self-reported measures of pain and function. Although specific injury mechanisms are still not fully understood, these findings lend additional insight into the development of rotator cuff pathology in swimmers. CLINICAL RELEVANCE Lengthy swimming careers may lead to a chronic condition of reduced mechanical properties in the supraspinatus muscle and tendon, thereby increasing the likelihood of rotator cuff pathology.
Collapse
|
23
|
Effects of asymptomatic rotator cuff pathology on in vivo shoulder motion and clinical outcomes. J Shoulder Elbow Surg 2017; 26:1064-1072. [PMID: 28131679 PMCID: PMC5438772 DOI: 10.1016/j.jse.2016.11.048] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Revised: 11/15/2016] [Accepted: 11/25/2016] [Indexed: 02/01/2023]
Abstract
BACKGROUND The incidence of asymptomatic rotator cuff tears has been reported to range from 15% to 39%, but the influence of asymptomatic rotator cuff pathology on shoulder function is not well understood. This study assessed the effects of asymptomatic rotator cuff pathology on shoulder kinematics, strength, and patient-reported outcomes. METHODS A clinical ultrasound examination was performed in 46 asymptomatic volunteers (age: 60.3 ± 7.5 years) with normal shoulder function to document the condition of their rotator cuff. The ultrasound imaging identified the participants as healthy (n = 14) or pathologic (n = 32). Shoulder motion was measured with a biplane x-ray imaging system, strength was assessed with a Biodex (Biodex Medical Systems, Inc., Shirley, NY, USA), and patient-reported outcomes were assessed using the Western Ontario Rotator Cuff Index and visual analog scale pain scores. RESULTS Compared with healthy volunteers, those with rotator cuff pathology had significantly less abduction (P = .050) and elevation (P = .041) strength, their humerus was positioned more inferiorly on the glenoid (P = .018), and the glenohumeral contact path length was longer (P = .007). No significant differences were detected in the Western Ontario Rotator Cuff Index, visual analog scale, range of motion, or acromiohumeral distance. CONCLUSIONS The differences observed between the healthy volunteers and those with asymptomatic rotator cuff pathology lend insight into the changes in joint mechanics, shoulder strength, and conventional clinical outcomes associated with the early stages of rotator cuff pathology. Furthermore, these findings suggest a plausible mechanical progression of kinematic and strength changes associated with the development of rotator cuff pathology.
Collapse
|
24
|
Shear wave elastography of the supraspinatus muscle and tendon: Repeatability and preliminary findings. J Biomech 2017; 53:201-204. [PMID: 28110933 DOI: 10.1016/j.jbiomech.2017.01.008] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Revised: 11/14/2016] [Accepted: 01/05/2017] [Indexed: 12/18/2022]
Abstract
Shear wave elastography (SWE) is a promising tool for estimating musculoskeletal tissue properties, but few studies have rigorously assessed its repeatability and sources of error. The objectives of this study were to assess: (1) the extent to which probe positioning error and human user error influence measurement accuracy, (2) intra-user, inter-user, and day-to-day repeatability, and (3) the extent to which active and passive conditions affect shear wave speed (SWS) repeatability. Probe positioning and human usage errors were assessed by acquiring SWE images from custom ultrasound phantoms. Intra- and inter-user repeatability were assessed by two users acquiring five trials of supraspinatus muscle and tendon SWE images from ten human subjects. To assess day-to-day repeatability, five of the subjects were tested a second time, approximately 24h later. Imaging of the phantoms indicated high inter-user repeatability, with intraclass correlation coefficient (ICC) values of 0.68-0.85, and RMS errors of no more than 4.1%. SWE imaging of the supraspinatus muscle and tendon had high repeatability, with intra- and inter-user ICC values of greater than 0.87 and 0.73, respectively. Day-to-day repeatability demonstrated ICC values greater than 0.33 for passive muscle, 0.48 for passive tendon, 0.65 for active muscle, and 0.94 for active tendon. This study indicates the technique has good to very good intra- and inter-user repeatability, and day-to-day repeatability is appreciably higher when SWE images are acquired under a low level of muscle activation. The findings from this study establish the feasibility and repeatability of SWE for acquiring data longitudinally in human subjects.
Collapse
|
25
|
Characterization of Rotator Cuff Tears: Ultrasound Versus Magnetic Resonance Imaging. Orthopedics 2017; 40:e124-e130. [PMID: 27755645 DOI: 10.3928/01477447-20161013-04] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2016] [Accepted: 08/30/2016] [Indexed: 02/03/2023]
Abstract
Ultrasound and magnetic resonance imaging (MRI) are both capable of diagnosing full-thickness rotator cuff tears. However, it is unknown which imaging modality is more accurate and precise in evaluating the characteristics of full-thickness rotator cuff tears in a surgical population. This study reviewed 114 patients who underwent arthroscopic repair of a full-thickness rotator cuff tear over a 1-year period. Of these patients, 61 had both preoperative MRI and ultrasound for review. Three musculoskeletal radiologists evaluated each ultrasound and MRI in a randomized and blinded fashion on 2 separate occasions. Tear size, retraction status, muscle atrophy, and fatty infiltration were analyzed and compared between the 2 modalities. Ultrasound measurements were statistically smaller in both tear size (P=.001) and retraction status (P=.001) compared with MRI. The 2 image modalities showed comparable intraobserver reliability in assessment of tear size and retraction status. However, MRI showed greater interobserver reliability in assessment of tear size, retraction status, and atrophy. Independent observers are more likely to agree on measurements of the characteristics of rotator cuff tears when using MRI compared with ultrasound. As tear size increases, the 2 image modalities show greater differences in measurement of tear size and retraction status. Additionally, compared with MRI, ultrasound shows consistently low reliability in detecting subtle, but clinically important, degeneration of the soft tissue envelope. Although it is inexpensive and convenient, ultrasound may be best used to identify a tear, and MRI is superior for use in surgical planning for larger tears. [Orthopedics. 2017; 40(1):e124-e130.].
Collapse
|
26
|
Effects of Rotator Cuff Pathology and Physical Therapy on In Vivo Shoulder Motion and Clinical Outcomes in Patients With a Symptomatic Full-Thickness Rotator Cuff Tear. Orthop J Sports Med 2016; 4:2325967116666506. [PMID: 27734020 PMCID: PMC5040201 DOI: 10.1177/2325967116666506] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
Abstract
BACKGROUND Physical therapy (PT) is often prescribed for patients with rotator cuff tears. The extent to which PT influences strength, range of motion (ROM), and patient-reported outcomes has been studied extensively, but the effect of PT on in vivo joint kinematics is not well understood. PURPOSE To assess the influence of symptomatic rotator cuff pathology and the effects of PT on shoulder motion, strength, and patient-reported outcomes. STUDY DESIGN Controlled laboratory study. METHODS Twenty-five patients with a symptomatic rotator cuff tear and 25 age-matched asymptomatic control subjects were recruited. Shoulder motion was measured using a biplane radiography imaging system, strength was assessed with a Biodex dynamometer, and patient-reported outcomes were assessed using the Western Ontario Rotator Cuff Index and visual analog scale (VAS) pain scores. Data were acquired from the patients before and after 8 weeks of physical therapy. Data were acquired at 1 time point for the control subjects. RESULTS Compared with the control subjects, patients with a symptomatic rotator cuff tear had significantly worse pain/function scores (P < .01); less ROM (P < .01); lower abduction (ABD), external rotation (ER), and internal rotation (IR) strength (P < .01); less scapulothoracic posterior tilt (P = .05); and lower glenohumeral joint elevation (P < .01). Physical therapy resulted in improved pain/function scores (P < .01), increased ROM (P < .02), increased scapulothoracic posterior tilt (P = .05), increased glenohumeral joint elevation (P = .01), and decreased acromiohumeral distance (AHD) (P = .02). CONCLUSION Compared with age-matched controls, patients had worse pain/function scores, less ROM, and lower ABD, ER, and IR strength. Patients also had less scapulothoracic anteroposterior tilt, less glenohumeral joint elevation, and an altered glenohumeral joint contact path. PT resulted in improved pain/function scores, increased ROM, greater posterior scapulothoracic tilt, increased glenohumeral joint elevation, an increased range of superoinferior joint contact, and a lower mean AHD. Of these differences, PT only returned scapulothoracic tilt to control levels. CLINICAL RELEVANCE This study documents the effects of PT on shoulder motion and conventional clinical outcomes. It is expected that understanding how changes in joint motion are associated with conventional clinical outcomes will lead to improved nonoperative interventions for patients with rotator cuff tears.
Collapse
|
27
|
Measuring Three-Dimensional Thorax Motion Via Biplane Radiographic Imaging: Technique and Preliminary Results. J Biomech Eng 2016; 138:2473568. [PMID: 26592901 DOI: 10.1115/1.4032058] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2015] [Indexed: 11/08/2022]
Abstract
Measures of scapulothoracic motion are dependent on accurate imaging of the scapula and thorax. Advanced radiographic techniques can provide accurate measures of scapular motion, but the limited 3D imaging volume of these techniques often precludes measurement of thorax motion. To overcome this, a thorax coordinate system was defined based on the position of rib pairs and then compared to a conventional sternum/spine-based thorax coordinate system. Alignment of the rib-based coordinate system was dependent on the rib pairs used, with the rib3:rib4 pairing aligned to within 4.4 ± 2.1 deg of the conventional thorax coordinate system.
Collapse
|
28
|
Effect of Arthroscopic Stabilization on In Vivo Glenohumeral Joint Motion and Clinical Outcomes in Patients With Anterior Instability. Am J Sports Med 2015; 43:2800-8. [PMID: 26391860 DOI: 10.1177/0363546515602249] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Glenohumeral joint (GHJ) dislocations are common, and the resulting shoulder instability is often treated with arthroscopic stabilization. These procedures result in favorable clinical outcomes, but abnormal GHJ motion may persist, which may place patients at risk for developing osteoarthritis. However, the effects of shoulder instability and arthroscopic stabilization on GHJ motion are not well understood. HYPOTHESIS GHJ motion is significantly influenced by anterior instability and arthroscopic stabilization, but postsurgical measures of GHJ motion are not different from those of control subjects. STUDY DESIGN Controlled laboratory study. METHODS In vivo GHJ motion was measured by applying a computed tomographic model-based tracking technique to biplane radiographic images acquired during an apprehension test in healthy control subjects (n = 11) and anterior instability patients (n = 11). Patients were tested before surgery and at 6 months after surgery. Control subjects were tested once. Shoulder strength, active range of motion (ROM), and the Western Ontario Shoulder Instability (WOSI) index were also measured. RESULTS Before surgery, the humerus of the instability patients during the apprehension test was located significantly more anteriorly on the glenoid (7.9% of glenoid width; 2.1 mm) compared with that of the controls (P = .03), but arthroscopic stabilization moved this joint contact location posteriorly on the glenoid (4.7% of glenoid width; 1.1 mm; P = .03). After surgery, GHJ excursion during the apprehension test was significantly lower (14.7% of glenoid width; 3.6 mm) compared with presurgical values (19.4% of glenoid width; 4.7 mm; P = .01) and with that of the controls (22.4% of glenoid width; 5.7 mm; P = .01). The external and internal rotation strength of patients was significantly lower than that of the controls before surgery (P < .05), but differences in strength did not persist after surgery (P > .17). External rotation ROM in patients was significantly lower than that in control subjects both before and after arthroscopic stabilization (P < .01). The WOSI score improved significantly, from 48.3 ± 13.1 presurgery to 86.3 ± 16.5 after surgery (P = .0002). CONCLUSION In patients with anterior instability, arthroscopic stabilization significantly improves measures of strength, ROM, and clinical outcome. However, GHJ excursion is not fully restored to levels seen in the control subjects. CLINICAL RELEVANCE Although arthroscopic stabilization satisfactorily restores most clinical outcome measures, GHJ excursion and external rotation ROM remain compromised compared with healthy control subjects and may contribute to the development of osteoarthritis in patients with anterior instability.
Collapse
|
29
|
Differences in glenohumeral joint morphology between patients with anterior shoulder instability and healthy, uninjured volunteers. J Shoulder Elbow Surg 2015; 24:1014-20. [PMID: 25958216 DOI: 10.1016/j.jse.2015.03.024] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Revised: 03/16/2015] [Accepted: 03/18/2015] [Indexed: 02/01/2023]
Abstract
BACKGROUND Traumatic glenohumeral joint (GHJ) dislocations are common, resulting in significant shoulder disability and pain. Previous research indicates that bony morphology is associated with an increased risk of injury in other joints (eg, the knee), but the extent to which bony morphology is associated with traumatic GHJ dislocation is unknown. This study assessed GHJ morphology in patients with anterior GHJ instability and in a control population of healthy volunteers. METHODS Bilateral computed tomography scans were used to measure GHJ morphology in both shoulders of 11 patients with instability and 11 control subjects. Specific outcome measures included the glenoid radius of curvature (ROC) in the anterior/posterior (A/P) and superior/inferior (S/I) directions, humeral head ROC, A/P and S/I conformity index, and A/P and S/I stability angle. RESULTS Compared with the control subjects, the glenoid of the instability the injured shoulder in patients with instability was flatter (ie, higher ROC) in the A/P (P = .001) and S/I (P = .01) directions and this finding was also true for uninjured, contralateral shoulder (A/P: P = .01, S/I: P = .03). No differences in GHJ morphology were detected between the instability patients' injured and contralateral shoulders (P > .07). Similarly, no differences in GHJ morphology were detected between the control subjects' dominant and nondominant shoulders (P > .51). CONCLUSIONS There are significant differences in GHJ morphology between healthy control subjects and both shoulders (injured and uninjured, contralateral) of patients diagnosed with anterior instability after GHJ dislocation. These findings are important clinically because they suggest that glenoid morphology may influence the risk of GHJ dislocation.
Collapse
|
30
|
Pitching performance and longevity after revision ulnar collateral ligament reconstruction in Major League Baseball pitchers. Am J Sports Med 2015; 43:1051-6. [PMID: 25862037 DOI: 10.1177/0363546515579636] [Citation(s) in RCA: 93] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Medial ulnar collateral ligament (UCL) reconstruction is a common procedure performed on professional pitchers in Major League Baseball (MLB). Although a great deal is known about primary reconstruction, much less is known about revision reconstruction. PURPOSE/HYPOTHESIS The purpose of this study was to evaluate statistical performance, return to play, and career longevity in MLB pitchers after revision UCL surgery, with the hypothesis that pitching performance and career longevity will decline after revision surgery. STUDY DESIGN Cohort study; Level of evidence, 3. METHODS A total of 33 MLB pitchers who underwent revision UCL reconstruction surgery (UCL-R group) were identified and compared with 33 age- and position-matched controls (CTL group). Return to play, total years played, and statistical performance were evaluated and compared with controls. RESULTS After revision surgery, 65.5% of UCL-R pitchers returned to the MLB level. On average, the UCL-R pitchers played 0.8 years less in the majors (P<.01) than did the control pitchers. The UCL-R pitchers who returned to the MLB level had a similar earned run average (UCL-R: 4.88, CTL: 4.76, P=.82) and walks/hits per innings pitched (UCL-R: 1.58, CTL: 1.44, P=.22) compared with the control pitchers. There were significant declines, however, in terms of innings pitched (UCL-R: 36.95, CTL: 75.00, P<.01), walks per 9 innings (UCL-R: 4.75, CTL: 3.49, P<.01), and wins (UCL-R: 1.88, CTL: 4.10, P<.01) as well as nonsignificant declines in wins above replacement (UCL-R: 0.25, CTL: 0.62, P=.06) and runs above replacement (UCL-R: 3.26, CTL: 6.91, P=.07). CONCLUSION MLB pitchers who undergo UCL-R have a low rate of return to MLB play and have shortened careers after return. Pitchers who returned to the MLB level maintained performance in several statistics such as earned run average and walks/hits per innings pitched; however, pitchers returned with a significantly decreased workload.
Collapse
|
31
|
Dynamic in-vivo assessment of navicular drop while running in barefoot, minimalist, and motion control footwear conditions. Gait Posture 2015; 41:825-9. [PMID: 25791869 DOI: 10.1016/j.gaitpost.2015.02.017] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2014] [Revised: 12/12/2014] [Accepted: 02/28/2015] [Indexed: 02/02/2023]
Abstract
Running-related injuries are common and previous research has suggested that the magnitude and/or rate of pronation may contribute to the development of these injuries. Accurately and directly measuring pronation can be challenging, and therefore previous research has often relied on navicular drop (under both static and dynamic conditions) as an indirect assessment of pronation. The objectives of this study were to use dynamic, biplane X-ray imaging to assess the effects of three footwear conditions (barefoot, minimalist shoes, motion control shoes) on the magnitude and rate of navicular drop during running, and to determine the association between static and dynamic measures of navicular drop. Twelve healthy distance runners participated in this study. The magnitude and rate of navicular drop were determined by tracking the 3D position of the navicular from biplane radiographic images acquired at 60Hz during the stance phase of overground running. Static assessments of navicular drop and foot posture were also recorded in each subject. Footwear condition was not found to have a significant effect on the magnitude of navicular drop (p=0.22), but motion control shoes had a slower navicular drop rate than running barefoot (p=0.05) or in minimalist shoes (p=0.05). In an exploratory analysis, static assessments of navicular drop and foot posture were found to be poor predictors of dynamic navicular drop in all footwear conditions (p>0.18).
Collapse
|
32
|
The effects of medial ulnar collateral ligament reconstruction on Major League pitching performance. J Shoulder Elbow Surg 2014; 23:1591-8. [PMID: 25183663 DOI: 10.1016/j.jse.2014.06.033] [Citation(s) in RCA: 69] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2014] [Revised: 05/26/2014] [Accepted: 06/09/2014] [Indexed: 02/01/2023]
Abstract
BACKGROUND Medial ulnar collateral ligament (MUCL) reconstruction is commonly performed on Major League Baseball (MLB) pitchers. Previous studies have reported that most pitchers return to presurgical statistical performance levels after MUCL reconstruction. METHODS Pitching performance data--specifically, earned run average (ERA), walks and hits per inning pitched (WHIP), winning percentage, and innings pitched--were acquired for 168 MLB pitchers who had undergone MUCL reconstruction. These data were averaged over the 3 years before surgery and the 3 years after surgery and also acquired from 178 age-matched, uninjured MLB pitchers. RESULTS Of the pitchers who had MUCL reconstruction surgery, 87% returned to MLB pitching. However, compared with presurgical data, pitching performance declined in terms of ERA (P = .001), WHIP (P = .011), and innings pitched (P = .026). Pitching performance also declined in the season before the surgery compared with previous years (ERA, P = .014; WHIP, P = .036; innings pitched, P < .001; winning percentage, P = .004). Compared with age-matched control pitchers, the MUCL reconstruction pitchers had significantly more major league experience at the same age (P < .001). CONCLUSION MUCL reconstruction allows most players to return to pitching at the major league level. However, after MUCL reconstruction, there is a statistically significant decline in pitching performance. There appears to be a statistically significant decline in pitching performance the year before reconstructive surgery, and this decline is also a risk factor for requiring surgery. In addition, there is an increased risk of MUCL reconstruction for pitchers who enter the major leagues at a younger age.
Collapse
|
33
|
Associations among shoulder strength, glenohumeral joint motion, and clinical outcome after rotator cuff repair. AMERICAN JOURNAL OF ORTHOPEDICS (BELLE MEAD, N.J.) 2014; 43:220-226. [PMID: 24839628 PMCID: PMC8091163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Rotator cuff tears are a common condition causing pain and disability, but the relationships among clinical measures of shoulder function and measures of glenohumeral joint (GHJ) function are not well known. In the study reported here, dynamic in vivo GHJ motion was measured during abduction from biplane radiographs in 22 rotator cuff repair (RCR) patients and 36 control subjects. Isometric shoulder strength was measured and clinical outcomes were assessed using the Western Ontario Rotator Cuff (WORC) Index. Associations among WORC, GHJ motion, and several shoulder strength ratios were assessed with linear regression. An association was detected between higher ER/ABD (external rotation/coronal-plane abduction) strength ratio and a humerus positioned more inferiorly relative to the glenoid in control subjects and RCR patients. Higher ER/ABD strength ratio was also associated with better clinical outcome in RCR patients. These findings suggest a relationship between ER/ABD strength ratio and a more centrally located average superior/inferior contact center in RCR patients and control subjects. The ER/ABD strength ratio can be easily measured in a clinical setting and therefore can be used in larger studies to investigate its relation to clinical outcomes over time or perhaps to predict superior migration of the humeral head.
Collapse
|
34
|
Measuring dynamic in-vivo elbow kinematics: description of technique and estimation of accuracy. J Biomech Eng 2014; 134:124502. [PMID: 23363209 DOI: 10.1115/1.4007951] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND The objectives of this study were to characterize the translational and rotational accuracy of a model-based tracking technique for quantifying elbow kinematics and to demonstrate its in vivo application. METHOD OF APPROACH The accuracy of a model-based tracking technique for quantifying elbow kinematics was determined in an in vitro experiment. Biplane X-ray images of a cadaveric elbow were acquired as it was manually moved through flexion-extension. The 3D position and orientation of each bone was determined using model-based tracking. For comparison, the position and orientation of each bone was also determined by tracking the position of implanted beads with dynamic radiostereometric analysis. Translations and rotations were calculated for both the ulnohumeral and radiohumeral joints, and compared between measurement techniques. To demonstrate the in vivo application of this technique, biplane X-ray images were acquired as a human subject extended their elbow from full flexion to full extension. RESULTS The in vitro validation demonstrated that the model-based tracking technique is capable of accurately measuring elbow motion, with reported errors averaging less than ±1.0 mm and ±1.0 deg. For the in vivo application, the carrying angle changed from an 8.3 ± 0.5 deg varus position in full flexion to an 8.4 ± 0.5 deg valgus position in full extension. CONCLUSIONS Model-based tracking is an accurate technique for measuring in vivo, 3D, dynamic elbow motion. It is anticipated that this experimental approach will enhance our understanding of elbow motion under normal and pathologic conditions.
Collapse
|
35
|
Three-dimensional motion analysis of the cervical spine for comparison of anterior cervical decompression and fusion versus artificial disc replacement in 17 patients. J Neurosurg Spine 2014; 20:245-55. [DOI: 10.3171/2013.11.spine13392] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Object
Cervical arthroplasty with an artificial disc (AD) has emerged as an alternative to anterior cervical discectomy and fusion (ACDF) for the management of cervical spondylosis. This study aims to provide 3D motion analysis data comparing patients after ACDF and AD replacement.
Methods
Ten patients who underwent C5–6 ACDF and 7 who underwent C5–6 AD replacement were enrolled. Using biplanar fluoroscopy and a model-based track technique (accurate up to 0.6 mm and 0.6°), motion analysis of axial rotation and flexion-extension of the neck was performed. Three nonoperative segments (C3–4, C4–5, and C6–7) were assessed for both intervertebral rotation (coronal, sagittal, and axial planes) and facet shear (anteroposterior and mediolateral).
Results
There was no difference in total neck motion comparing ACDF and AD replacement for neck extension (43.3° ± 10.2° vs 44.3° ± 12.6°, p = 0.866) and rotation (36.0° ± 6.5° vs 38.2° ± 9.3°, p = 0.576). For extension, when measured as a percentage of total neck motion, there was a greater amount of rotation at the nonoperated segments in the ACDF group than in the AD group (p = 0.003). When comparing specific motion segments, greater normalized rotation was seen in the ACDF group at C3–4 (33.2% ± 4.9% vs 26.8% ± 6.6%, p = 0.036) and C6–7 (28.5% ± 6.7% vs 20.5% ± 5.5%, p = 0.009) but not at C4–5 (33.5% ± 6.4% vs 31.8% ± 4.0%, p = 0.562). For neck rotation, greater rotation was observed at the nonoperative segments in the ACDF group than in the AD group (p = 0.024), but the differences between individual segments did not reach significance (p ≥ 0.146). Increased mediolateral facet shear was seen on neck extension with ACDF versus AD replacement (p = 0.008). Comparing each segment, C3–4 (0.9 ± 0.5 mm vs 0.4 ± 0.1 mm, p = 0.039) and C4–5 (1.0 ± 0.4 mm vs 0.5 ± 0.2 mm, p = 0.022) showed increased shear while C6–7 (1.0 ± 0.4 mm vs 1.0 ± 0.5 mm, p = 0.767) did not.
Conclusions
This study illustrates increased motion at nonoperative segments in patients who have undergone ACDF compared with those who have undergone AD replacement. Further studies will be required to examine whether these changes contribute to adjacent-segment disease.
Collapse
|
36
|
Shoe inversion does not represent ankle inversion: A dynamic x-ray analysis of barefoot and shod cutting. FOOTWEAR SCIENCE 2013. [DOI: 10.1080/19424280.2013.834980] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
37
|
Three dimensional, radiosteriometric analysis (RSA) of equine stifle kinematics and articular surface contact: a cadaveric study. Equine Vet J 2013; 46:364-9. [PMID: 23802689 DOI: 10.1111/evj.12127] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2013] [Accepted: 06/20/2013] [Indexed: 11/27/2022]
Abstract
REASONS FOR PERFORMING STUDY Studies examining the effect of stifle joint angle on tibial rotation, adduction-abduction angle and articular contact area are lacking. OBJECTIVES To test the hypothesis that tibial rotation, adduction-abduction angle and articular contact area change with stifle joint angle. STUDY DESIGN Descriptive study of normal kinematics and articular contact patterns of the equine stifle through the functional range of motion using 3 dimensional (3D) radiosteriometric analysis (RSA) and equine cadaver stifles. METHODS Multiple, radiopaque markers were embedded in the distal femur and proximal tibia and sequential, biplanar x-rays captured as the stifle was passively extended from 110° to full extension. Computer-programmed RSA was used to determine changes in abduction-adduction and internal-external rotation angles of the tibia during stifle extension as well as articular contact patterns (total area and areas of high contact) through the range of motion. RESULTS The tibia rotated externally (P < 0.001) as the stifle was extended. Tibial abduction occurred from 110-135° of extension (P < 0.001) and tibial adduction occurred from 135° through full extension (P = 0.009). The centre of joint contact moved cranially on both tibial condyles during extension with the lateral moving a greater distance than the medial (P = 0.003). Articular contact area decreased (P = 0.001) in the medial compartment but not in the lateral compartment (P = 0.285) as the stifle was extended. The area of highest joint contact increased on the lateral tibial condyle (P < 0.001) with extension but decreased (P = 0.001) on the medial tibial condyle. CONCLUSIONS Significant changes occur in tibial rotation, adduction-abduction angle and articular contact area of the equine stifle through the functional range of motion. Understanding the normal kinematics of the equine stifle and the relationship between joint positions and articular contact areas may provide important insight into the aetiology and location of common stifle joint pathologies (articular cartilage and meniscal lesions).
Collapse
|
38
|
Do high-top shoes reduce ankle inversion? A dynamic x-ray analysis of aggressive cutting in a high-top and low-top shoe. FOOTWEAR SCIENCE 2013. [DOI: 10.1080/19424280.2013.834981] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
39
|
Abstract
BACKGROUND Ten to seventy percent of rotator cuff repairs form a recurrent defect after surgery. The relationship between retraction of the repaired tendon and formation of a recurrent defect is not well defined. PURPOSE/ HYPOTHESES: To measure the prevalence, timing, and magnitude of tendon retraction after rotator cuff repair and correlate these outcomes with formation of a full-thickness recurrent tendon defect on magnetic resonance imaging, as well as clinical outcomes. We hypothesized that (1) tendon retraction is a common phenomenon, although not always associated with a recurrent defect; (2) formation of a recurrent tendon defect correlates with the timing of tendon retraction; and (3) clinical outcome correlates with the magnitude of tendon retraction at 52 weeks and the formation of a recurrent tendon defect. STUDY DESIGN Case series; Level of evidence, 4. METHODS Fourteen patients underwent arthroscopic rotator cuff repair. Tantalum markers placed within the repaired tendons were used to assess tendon retraction by computed tomography scan at 6, 12, 26, and 52 weeks after operation. Magnetic resonance imaging was performed to assess for recurrent tendon defects. Shoulder function was evaluated using the Penn score, visual analog scale (VAS) score for pain, and isometric scapular-plane abduction strength. RESULTS All rotator cuff repairs retracted away from their position of initial fixation during the first year after surgery (mean [standard deviation], 16.1 [5.3] mm; range, 5.7-23.2 mm), yet only 30% of patients formed a recurrent defect. Patients who formed a recurrent defect tended to have more tendon retraction during the first 6 weeks after surgery (9.7 [6.0] mm) than those who did not form a defect (4.1 [2.2] mm) (P = .08), but the total magnitude of tendon retraction was not significantly different between patient groups at 52 weeks. There was no significant correlation between the magnitude of tendon retraction and the Penn score (r = 0.01, P = .97) or normalized scapular abduction strength (r = -0.21, P = .58). However, patients who formed a recurrent defect tended to have lower Penn scores at 52 weeks (P = .1). CONCLUSION Early tendon retraction, but not the total magnitude, correlates with formation of a recurrent tendon defect and worse clinical outcomes. "Failure with continuity" (tendon retraction without a recurrent defect) appears to be a common phenomenon after rotator cuff repair. These data suggest that repairs should be protected in the early postoperative period and repair strategies should endeavor to mechanically and biologically augment the repair during this critical early period.
Collapse
|
40
|
In vivo shoulder function after surgical repair of a torn rotator cuff: glenohumeral joint mechanics, shoulder strength, clinical outcomes, and their interaction. Am J Sports Med 2011; 39:2117-29. [PMID: 21737834 PMCID: PMC4601100 DOI: 10.1177/0363546511412164] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Surgical repair of a torn rotator cuff is based on the belief that repairing the tear is necessary to restore normal glenohumeral joint (GHJ) mechanics and achieve a satisfactory clinical outcome. HYPOTHESIS Dynamic joint function is not completely restored by rotator cuff repair, thus compromising shoulder function and potentially leading to long-term disability. STUDY DESIGN Controlled laboratory study and Case series; Level of evidence, 4. METHODS Twenty-one rotator cuff patients and 35 control participants enrolled in the study. Biplane radiographic images were acquired bilaterally from each patient during coronal-plane abduction. Rotator cuff patients were tested at 3, 12, and 24 months after repair of a supraspinatus tendon tear. Control participants were tested once. Glenohumeral joint kinematics and joint contact patterns were accurately determined from the biplane radiographic images. Isometric shoulder strength and patient-reported outcomes were measured at each time point. Ultrasound imaging assessed rotator cuff integrity at 24 months after surgery. RESULTS Twenty of 21 rotator cuff repairs appeared intact at 24 months after surgery. The humerus of the patients' repaired shoulder was positioned more superiorly on the glenoid than both the patients' contralateral shoulder and the dominant shoulder of control participants. Patient-reported outcomes improved significantly over time. Shoulder strength also increased over time, although strength deficits persisted at 24 months for most patients. Changes over time in GHJ mechanics were not detected for either the rotator cuff patients' repaired or contralateral shoulders. Clinical outcome was associated with shoulder strength but not GHJ mechanics. CONCLUSION Surgical repair of an isolated supraspinatus tear may be sufficient to keep the torn rotator cuff intact and achieve satisfactory patient-reported outcomes, but GHJ mechanics and shoulder strength are not fully restored with current repair techniques. CLINICAL RELEVANCE The study suggests that current surgical repair techniques may be effective for reducing pain but have not yet been optimized for restoring long-term shoulder function.
Collapse
|
41
|
Estimation of dynamic, in vivo soft-tissue deformation: experimental technique and application in a canine model of tendon injury and repair. J Orthop Res 2011; 29:822-7. [PMID: 21520256 PMCID: PMC6100779 DOI: 10.1002/jor.21315] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2010] [Accepted: 10/08/2010] [Indexed: 02/04/2023]
Abstract
Outcomes after rotator cuff surgery are typically assessed with measures of strength, joint motion, or pain, but these measures do not provide a direct assessment of tissue function as healing progresses. To address this limitation, this manuscript describes biplane X-ray analysis as a technique for quantifying in vivo soft-tissue deformation. Tantalum beads were implanted in the humerus and infraspinatus tendon in a canine model of tendon injury and repair. Biplane X-ray images were acquired during treadmill trotting and tissue deformation was estimated from the three-dimensional bead positions. Changes over time were characterized by the mean, range, and normalized range (i.e., range/mean) of interbead distance. Intact tendon repair tissue demonstrated significant decreases over time in the mean (p = 0.003), range (p = 0.001), and normalized range (p = 0.001) of interbead distance. Failed tendon repair tissue demonstrated significant decreases over time in the range (p = 0.05) and normalized range (p = 0.04) of interbead distance. In an uninjured control, differences over time in the interbead distance parameters were not detected. This approach is a promising technique for estimating changes over time in soft-tissue deformation. These preliminary data indicate appreciable differences between normal tendons, intact repairs, and failed repairs.
Collapse
|
42
|
Tibiofemoral joint kinematics of the anterior cruciate ligament-reconstructed knee during a single-legged hop landing. Am J Sports Med 2010; 38:1820-8. [PMID: 20472756 DOI: 10.1177/0363546510365531] [Citation(s) in RCA: 92] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Abnormal 3-dimensional tibiofemoral joint kinematics have been identified in anterior cruciate ligament-reconstructed knees during functional gait tasks, which is suggested to directly affect risk of knee osteoarthritis. However, the extent to which similar high-risk abnormalities are present during more demanding maneuvers, such as single-legged hopping, is largely unknown. HYPOTHESIS When performing a single-legged forward hop landing, the reconstructed knee will demonstrate altered sagittal, frontal, and transverse plane kinematics compared with the contralateral limb. STUDY DESIGN Controlled laboratory study. METHODS High-speed biplane radiography was used to quantify bilateral 3-dimensional tibiofemoral joint kinematics in 9 subjects with unilaterally reconstructed anterior cruciate ligaments (mean time after surgery, 4 months) during 3 single-legged, forward hop landing trials. Mean subject-based initial foot contact and maximum stance (0-250 ms) values were calculated for each kinematic variable. Two-tailed paired t tests were subsequently applied to examine for the main effect of limb (reconstructed vs contralateral). RESULTS The reconstructed knees exhibited significantly greater extension (P = .04), external tibial rotation (P = .006), and medial tibial translation (P = .02) than the contralateral knees at initial contact. Reconstructed knees underwent significantly greater maximum flexion (P = .05), maximum external tibial rotation (P = .01), and maximum anterior tibial translation (P = .02). No significant differences existed between limbs for initial contact (P = .65) or maximum adduction-abduction (P = .55). CONCLUSION Tibiofemoral joint kinematics of the anterior cruciate ligament-reconstructed knee are significantly different from those of the uninjured contralateral limb during a single-legged hop landing. This altered kinematic profile, in conjunction with the large impact loads associated with hopping, may further contribute to the risk of posttraumatic knee osteoarthritis. CLINICAL RELEVANCE Returning to sports involving dynamic single-legged landings at 4 months after anterior cruciate ligament reconstruction surgery may contribute to accelerated knee joint degeneration.
Collapse
|
43
|
Associations among hip and shoulder range of motion and shoulder injury in professional baseball players. J Athl Train 2010; 45:191-7. [PMID: 20210623 DOI: 10.4085/1062-6050-45.2.191] [Citation(s) in RCA: 97] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
CONTEXT The overhead throwing motion is complex, and restrictions in range of motion (ROM) at the hip may place additional demands on the shoulder that lead to injury. However, the relationship between hip and shoulder ROM in athletes with and without a history of shoulder injury is unknown. OBJECTIVE To (1) determine if differences exist in hip and shoulder ROM between professional baseball players with a history of shoulder injury and those with no history of shoulder injury and (2) assess relationships between hip and shoulder ROM in these players. DESIGN Cross-sectional study. PATIENTS OR OTHER PARTICIPANTS Fifty-seven professional baseball players. MAIN OUTCOME MEASURE(S) Outcome measures consisted of hip extension and internal rotation, shoulder internal and external rotation, glenohumeral internal-rotation deficit, and history of shoulder injury. Differences in shoulder and hip ROM were assessed with a 1-way analysis of variance. Associations between hip and shoulder ROM were assessed with linear regression. RESULTS Nonpitchers with a history of shoulder injury had more external rotation and less internal rotation of the shoulder than nonpitchers with no history of shoulder injury. Glenohumeral internal-rotation deficit was greater in both pitchers and nonpitchers with a history of shoulder injury. The relationship between dominant hip extension and shoulder external rotation was significant for pitchers with a history of shoulder injury and nonpitchers with a history of shoulder injury. CONCLUSIONS Shoulder injury may be associated with specific measures of hip and shoulder ROM, and hip extension and shoulder external rotation may be related in baseball players with a history of shoulder injury. Additional research is necessary to understand the specific mechanisms of shoulder injury in the throwing athlete.
Collapse
|
44
|
Three-dimensional dynamic in vivo motion of the cervical spine: assessment of measurement accuracy and preliminary findings. Spine J 2010; 10:497-504. [PMID: 20359957 DOI: 10.1016/j.spinee.2010.02.024] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2009] [Revised: 01/18/2010] [Accepted: 02/18/2010] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT Previous research has quantified cervical spine motion with conventional measurement techniques (eg, cadaveric studies, motion capture systems, and fluoroscopy), but these techniques were not designed to accurately measure three-dimensional (3D) dynamic cervical spine motion under in vivo conditions. PURPOSE The purposes of this study were to characterize the accuracy of model-based tracking for measuring 3D dynamic cervical spine kinematics and to demonstrate its in vivo application. STUDY DESIGN Through accuracy assessment and application of technique, in vivo cervical spine motion was measured. METHODS The accuracy of model-based tracking for measuring cervical spine motion was determined in an in vitro experiment. Tantalum beads were implanted into the vertebrae of an ovine specimen, and biplane X-ray images were acquired as the specimen's neck was manually moved through neck extension and axial neck rotation. The 3D position and orientation of each cervical vertebra were determined from the biplane X-ray images using model-based tracking. For comparison, the position and orientation of each vertebra were also determined by tracking the position of the implanted beads with dynamic radiostereometric analysis. To demonstrate in vivo application of this technique, biplane X-ray images were acquired as a human subject performed two motion tasks: neck extension and axial neck rotation. The positions and orientations of each cervical vertebra were determined with model-based tracking. Cervical spine motion was reported with standard kinematic descriptions of translation and rotation. RESULTS The in vitro validation demonstrated that model-based tracking is accurate to within +/-0.6 mm and +/-0.6 degrees for measuring cervical spine motion. For the in vivo application, there were significant rotations about all three anatomical axes for both the neck extension and axial neck rotation motion tasks. CONCLUSIONS Model-based tracking is an accurate technique for measuring in vivo, 3D, dynamic cervical spine motion. Preliminary data acquired using this technique are in agreement with previous studies. It is anticipated that this experimental approach will enhance our understanding of cervical spine motion under normal and pathologic conditions.
Collapse
|
45
|
In Vivo Measurement of Glenohumeral Joint Contact Patterns. EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING 2010; 2010:162136. [PMID: 21546990 PMCID: PMC3086287 DOI: 10.1155/2010/162136] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
The objectives of this study were to describe a technique for measuring in-vivo glenohumeral joint contact patterns during dynamic activities and to demonstrate application of this technique. The experimental technique calculated joint contact patterns by combining CT-based 3D bone models with joint motion data that were accurately measured from biplane x-ray images. Joint contact patterns were calculated for the repaired and contralateral shoulders of 20 patients who had undergone rotator cuff repair. Significant differences in joint contact patterns were detected due to abduction angle and shoulder condition (i.e., repaired versus contralateral). Abduction angle had a significant effect on the superior/inferior contact center position, with the average joint contact center of the repaired shoulder 12.1% higher on the glenoid than the contralateral shoulder. This technique provides clinically relevant information by calculating in-vivo joint contact patterns during dynamic conditions and overcomes many limitations associated with conventional techniques for quantifying joint mechanics.
Collapse
|
46
|
Mechanisms of traumatic rupture of the aorta and associated peri-isthmic motion and deformation. STAPP CAR CRASH JOURNAL 2008; 52:233-65. [PMID: 19085165 DOI: 10.4271/2008-22-0010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
This study investigated the mechanisms of traumatic rupture of the aorta (TRA). Eight unembalmed human cadavers were tested using various dynamic blunt loading modes. Impacts were conducted using a 32-kg impactor with a 152-mm face, and high-speed seatbelt pretensioners. High-speed biplane x-ray was used to visualize aortic motion within the mediastinum, and to measure deformation of the aorta. An axillary thoracotomy approach was used to access the peri-isthmic region to place radiopaque markers on the aorta. The cadavers were inverted for testing. Clinically relevant TRA was observed in seven of the tests. Peak average longitudinal Lagrange strain was 0.644, with the average peak for all tests being 0.208 +/- 0.216. Peak intraluminal pressure of 165 kPa was recorded. Longitudinal stretch of the aorta was found to be a principal component of injury causation. Stretch of the aorta was generated by thoracic deformation, which is required for injury to occur. The presence of atherosclerosis was demonstrated to promote injury. The isthmus of the aorta moved dorsocranially during frontal impact and submarining loading modes. The aortic isthmus moved medially and anteriorly during impact to the left side. The results of this study provide a better understanding of the mechanisms associated with TRA, and can be used for the validation of finite element models developed for the examination and prediction of TRA.
Collapse
|
47
|
Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion. J Orthop Surg Res 2008; 3:38. [PMID: 18771582 PMCID: PMC2538511 DOI: 10.1186/1749-799x-3-38] [Citation(s) in RCA: 86] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2008] [Accepted: 09/04/2008] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Accurately measuring in-vivo motion of the knee's patellofemoral (PF) joint is challenging. Conventional measurement techniques have largely been unable to accurately measure three-dimensional, in-vivo motion of the patella during dynamic activities. The purpose of this study was to assess the accuracy of a new model-based technique for measuring PF joint motion. METHODS To assess the accuracy of this technique, we implanted tantalum beads into the femur and patella of three cadaveric knee specimens and then recorded dynamic biplane radiographic images while manually flexing and extending the specimen. The position of the femur and patella were measured from the biplane images using both the model-based tracking system and a validated dynamic radiostereometric analysis (RSA) technique. Model-based tracking was compared to dynamic RSA by computing measures of bias, precision, and overall dynamic accuracy of four clinically-relevant kinematic parameters (patellar shift, flexion, tilt, and rotation). RESULTS The model-based tracking technique results were in excellent agreement with the RSA technique. Overall dynamic accuracy indicated errors of less than 0.395 mm for patellar shift, 0.875 degrees for flexion, 0.863 degrees for tilt, and 0.877 degrees for rotation. CONCLUSION This model-based tracking technique is a non-invasive method for accurately measuring dynamic PF joint motion under in-vivo conditions. The technique is sufficiently accurate in measuring clinically relevant changes in PF joint motion following conservative or surgical treatment.
Collapse
|
48
|
Measuring dynamic in-vivo glenohumeral joint kinematics: technique and preliminary results. J Biomech 2007; 41:711-4. [PMID: 17996874 DOI: 10.1016/j.jbiomech.2007.09.029] [Citation(s) in RCA: 94] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2007] [Revised: 09/24/2007] [Accepted: 09/25/2007] [Indexed: 11/16/2022]
Abstract
Rotator cuff tears are a common injury that affect a significant percentage of the population over age 60. Although it is widely believed that the rotator cuff's primary function is to stabilize the humerus against the glenoid during shoulder motion, accurately measuring the three-dimensional (3D) motion of the shoulder's glenohumeral joint under in-vivo conditions has been a challenging endeavor. In particular, conventional motion measurement techniques have frequently been limited to static or two-dimensional (2D) analyses, and have suffered from limited or unknown in-vivo accuracy. We have recently developed and validated a new model-based tracking technique that is capable of accurately measuring the 3D position and orientation of the scapula and humerus from biplane X-ray images. Herein we demonstrate the in-vivo application of this technique for accurately measuring glenohumeral joint translations during shoulder motion in the repaired and contralateral shoulders of patients following rotator cuff repair. Five male subjects were tested at 3-4 months following arthroscopic rotator cuff repair. Superior-inferior humeral translation was measured during elevation, and anterior-posterior humeral translation was measured during external rotation in both the repaired and contralateral shoulders. The data failed to detect statistically significant differences between the repaired and contralateral shoulders in superior-inferior translation (p=0.74) or anterior-posterior translation (p=0.77). The measurement technique overcomes the limitations of conventional motion measurement techniques by providing accurate, 3D, in-vivo measures of glenohumeral joint motion during dynamic activities. On-going research is using this technique to assess the effects of conservative and surgical treatment of rotator cuff tears.
Collapse
|
49
|
In vivo measurement of subacromial space width during shoulder elevation: technique and preliminary results in patients following unilateral rotator cuff repair. Clin Biomech (Bristol, Avon) 2007; 22:767-73. [PMID: 17560699 PMCID: PMC2033432 DOI: 10.1016/j.clinbiomech.2007.04.006] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2007] [Revised: 04/10/2007] [Accepted: 04/11/2007] [Indexed: 02/07/2023]
Abstract
BACKGROUND The shoulder's subacromial space is of significant clinical interest due to its association with rotator cuff disease. Previous studies have estimated the subacromial space width to be 2-17 mm, but no study has measured in vivo subacromial space width during shoulder motion. The purpose of this study was to measure the in vivo subacromial space width during shoulder elevation in patients following rotator cuff repair. METHODS Biplane X-ray images were collected during shoulder elevation of 11 patients who had undergone rotator cuff repair. Glenohumeral joint motion was measured from the biplane X-ray images for each subject's repaired and asymptomatic, contralateral shoulders. The joint motion data were combined with subject-specific CT models to measure the subacromial space width during shoulder motion. FINDINGS Subacromial space width decreased with shoulder elevation, ranging from 2.3 to 7.4 mm in the repaired shoulder and 1.2-7.1 mm in the contralateral shoulder. Subacromial space width in the repaired shoulder was only 0.5 mm less than the contralateral shoulder when averaged over 10-60 degrees of glenohumeral elevation. INTERPRETATION The results indicate that the humerus in the repaired shoulder is positioned more cranially on the glenoid than in the contralateral shoulder. It is unclear if these subtle differences in subacromial space width are due to the surgical procedure or post-operative stiffness, or if subacromial impingement contributed to the development of the rotator cuff tear. Future research will ascertain if these results represent a transient response to the surgery or a more fundamental difference in rotator cuff function between repaired and contralateral shoulders.
Collapse
|
50
|
Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics. J Biomech Eng 2006; 128:604-9. [PMID: 16813452 PMCID: PMC3072582 DOI: 10.1115/1.2206199] [Citation(s) in RCA: 207] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Shoulder motion is complex and significant research efforts have focused on measuring glenohumeral joint motion. Unfortunately, conventional motion measurement techniques are unable to measure glenohumeral joint kinematics during dynamic shoulder motion to clinically significant levels of accuracy. The purpose of this study was to validate the accuracy of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics. We have developed a model-based tracking technique for accurately measuring in vivo joint motion from biplane radiographic images that tracks the position of bones based on their three-dimensional shape and texture. To validate this technique, we implanted tantalum beads into the humerus and scapula of both shoulders from three cadaver specimens and then recorded biplane radiographic images of the shoulder while manually moving each specimen's arm. The position of the humerus and scapula were measured using the model-based tracking system and with a previously validated dynamic radiostereometric analysis (RSA) technique. Accuracy was reported in terms of measurement bias, measurement precision, and overall dynamic accuracy by comparing the model-based tracking results to the dynamic RSA results. The model-based tracking technique produced results that were in excellent agreement with the RSA technique. Measurement bias ranged from -0.126 to 0.199 mm for the scapula and ranged from -0.022 to 0.079 mm for the humerus. Dynamic measurement precision was better than 0.130 mm for the scapula and 0.095 mm for the humerus. Overall dynamic accuracy indicated that rms errors in any one direction were less than 0.385 mm for the scapula and less than 0.374 mm for the humerus. These errors correspond to rotational inaccuracies of approximately 0.25 deg for the scapula and 0.47 deg for the humerus. This new model-based tracking approach represents a non-invasive technique for accurately measuring dynamic glenohumeral joint motion under in vivo conditions. The model-based technique achieves accuracy levels that far surpass all previously reported non-invasive techniques for measuring in vivo glenohumeral joint motion. This technique is supported by a rigorous validation study that provides a realistic simulation of in vivo conditions and we fully expect to achieve these levels of accuracy with in vivo human testing. Future research will use this technique to analyze shoulder motion under a variety of testing conditions and to investigate the effects of conservative and surgical treatment of rotator cuff tears on dynamic joint stability.
Collapse
|