1
|
Sweat analysis with a wearable sensing platform based on laser-induced graphene. APL Bioeng 2022; 6:036104. [PMID: 36147196 PMCID: PMC9489259 DOI: 10.1063/5.0093301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 08/23/2022] [Indexed: 11/15/2022] Open
Abstract
The scientific community has shown increasing interest in laser scribing for the direct fabrication of conductive graphene-based tracks on different substrates. This can enable novel routes for the noninvasive analysis of biofluids (such as sweat or other noninvasive matrices), whose results can provide the rapid evaluation of a person's health status. Here, we present a wearable sensing platform based on laser induced graphene (LIG) porous electrodes scribed on a flexible polyimide sheet, which samples sweat through a paper sampler. The device is fully laser manufactured and features a two layer design with LIG-based vertical interconnect accesses. A detailed characterization of the LIG electrodes including pore size, surface groups, surface area in comparison to electroactive surface area, and the reduction behavior of different LIG types was performed. The bare LIG electrodes can detect the electrochemical oxidation of both uric acid and tyrosine. Further modification of the surface of the LIG working electrode with an indoaniline derivative [4-((4-aminophenyl)imino)-2,6-dimethoxycyclohexa-2,5-dien-1-one] enables the voltammetric measurement of pH with an almost ideal sensitivity and without interference from other analytes. Finally, electrochemical impedance spectroscopy was used to measure the concentrations of ions through the analysis of the sweat impedance. The device was successfully tested in a real case scenario, worn on the skin during a sports session. In vitro tests proved the non-cytotoxic effect of the device on the A549 cell line.
Collapse
|
2
|
COVID-19 pandemic and eating disorders: What impact on specific and general psychopathology? Eur Psychiatry 2021. [PMCID: PMC9471239 DOI: 10.1192/j.eurpsy.2021.328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Introduction The coronavirus disease 2019 (COVID-19) pandemic and the resulting containment measures, such as “lockdown” and “social distancing”, have had important consequences on people’s mental and physical health. Objectives We aimed to study the effect of social isolation and subsequent re- exposure and eventual changes in general and ED-specific psychopathology in people with Eating Disorders (EDs). Methods Three-hundred twelve Italian people with EDs (179 Anorexia Nervosa, 83 Bulimia Nervosa, 48 Binge Eating Disorder and 22 Other Specific Feeding Eating Disorder) were asked to fill-in an online survey to explore several dimensions such as: anxiety, depression, panic, insomnia, suicide ideation, stress, post-traumatic stress and obsessive-compulsive symptoms. Differences in ED specific and general symptoms among the 3 investigated time periods (before, during and after the end of lockdown) were assessed with a one-way ANOVA with repeated measures. Subsequently, ED diagnosis was introduced as covariate in the analysis in order to investigate the possible contribution on psychopathological changes. Results ED core symptoms increased during the lockdown but most of them returned to pre-COVID19 levels at re-opening. The severity of general psychopathology also increased during the lockdown and persisted high in the following phase, except for depression and suicide ideation. None of this symptoms was affected by ED diagnosis, participants’age and illness duration. Conclusions People with EDs showed worsening of both general and specific psychopathology; moreover, changes in general psychopathology persisted in the re-opening period suggesting a higher stress vulnerability in this kind of patients. Disclosure No significant relationships. Keyword COVID19 and Eating Disorders
Collapse
|
3
|
The novel Mechanical Ventilator Milano for the COVID-19 pandemic. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2021; 33:037122. [PMID: 33897243 PMCID: PMC8060010 DOI: 10.1063/5.0044445] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/16/2021] [Accepted: 02/14/2021] [Indexed: 06/12/2023]
Abstract
This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world.
Collapse
|
4
|
A graphene-based pH sensor on paper for human plasma and seawater. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:1563-1566. [PMID: 31946193 DOI: 10.1109/embc.2019.8856991] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The relevance of pH assessment in clinical analysis, environmental and industrial control, has raised the demand for the development of portable, low cost and easy-to-use monitoring systems. This paper proposes a pH sensor printed on a paper support passivated with a solid-ink coating. The sensor exploits the pH sensitivity of a reduced graphene oxide functionalized with 3-(4-aminophenil)propionic acid. The sensor responded in the pH range [4], [10] and had a sensitivity of 46 mV/pH. Tests on human plasma and seawater proved this pH sensor to have similar performances than those of a commercial pH-meter with an uncertainty of 0.1 and 0.2 pH unit in plasma and seawater, respectively.
Collapse
|
5
|
A Biosensor for the Detection of Acetylcholine and Diazinon. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:1159-1162. [PMID: 31946099 DOI: 10.1109/embc.2019.8856959] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Acetylcholine is a neurotransmitter and a neuromodulator found in the autonomic, peripheral and central nervous systems. Diazinon is a pesticide with toxic effects on humans, such as the inhibition of acetylcholine. In this paper, a biosensor is proposed for the detection of acetylcholine (range 70 - 1000 μM) and diazinon (range 0.3 - 20000 ppb). This biosensor combines a pH-sensitive layer of reduced graphene oxide functionalized with 4-aminobenzoic acid and acetylcholinesterase. This enzyme was immobilized on reduced graphene oxide and it catalyzed the conversion of acetylcholine into choline and acetic acid, locally decreasing the pH value and triggering the sensor response. The limit of detection for the acetylcholine and diazinon were 70 μM and 0.3 ppb, respectively.
Collapse
|
6
|
A sampler prototype for the simultaneous collection of exhaled air and breath condensate. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:2226-2229. [PMID: 31946343 DOI: 10.1109/embc.2019.8856302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Exhaled air and breath condensate contain a large number of health biomarkers, such as volatile and semi-volatile organic compounds, proteins and lipids. Nowadays, the collection of breath samples is carried out by commercial or lab-made sampling systems that collect only one type of sample (e.g. gaseous or condensate phase), thus limiting the diagnostic capability of breath tests. This work presents a portable prototype optimized for the simultaneous collection of gaseous exhaled breath and exhaled breath condensate within five minutes. The system is fully portable and has a total weight of about 1 Kg. An illustrative determination of ethanol, isoprene, acetone, isopropyl alcohol, 1-propanol, 2-butanone, 2-pentanone, toluene and xylenes in breath, and cortisol and 8-iso-prostaglandin F2α in breath condensate is discussed.
Collapse
|
7
|
|
8
|
Determination of carbonyl compounds in exhaled breath by on-sorbent derivatization coupled with thermal desorption and gas chromatography-tandem mass spectrometry. J Breath Res 2018; 12:046004. [DOI: 10.1088/1752-7163/aad202] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
9
|
|
10
|
Determination of salivary α-amylase and cortisol in psoriatic subjects undergoing the Trier Social Stress Test. Microchem J 2018. [DOI: 10.1016/j.microc.2017.04.033] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
|
11
|
Determination of volatile organic compounds in exhaled breath of heart failure patients by needle trap micro-extraction coupled with gas chromatography-tandem mass spectrometry. J Breath Res 2017; 11:047110. [PMID: 29052557 DOI: 10.1088/1752-7163/aa94e7] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The analytical performances of needle trap micro-extraction (NTME) coupled with gas chromatography-tandem mass spectrometry were evaluated by analyzing a mixture of twenty-two representative breath volatile organic compounds (VOCs) belonging to different chemical classes (i.e. hydrocarbons, ketones, aldehydes, aromatics and sulfurs). NTME is an emerging technique that guarantees detection limits in the pptv range by pre-concentrating low volumes of sample, and it is particularly suitable for breath analysis. For most VOCs, detection limits between 20 and 500 pptv were obtained by pre-concentrating 25 ml of a humidified standard gas mixture at a flow rate of 15 ml min-1. For all compounds, inter- and intra-day precisions were always below 15%, confirming the reliability of the method. The procedure was successfully applied to the analysis of exhaled breath samples collected from forty heart failure (HF) patients during their stay in the University Hospital of Pisa. The majority of patients (about 80%) showed a significant decrease of breath acetone levels (a factor of 3 or higher) at discharge compared to admission (acute phase) in correspondence to the improved clinical conditions during hospitalization, thus making this compound eligible as a biomarker of HF exacerbation.
Collapse
|
12
|
A graphene oxide pH sensor for wound monitoring. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:1898-1901. [PMID: 28324956 DOI: 10.1109/embc.2016.7591092] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
This article describes the fabrication and characterization of a pH sensor for monitoring the wound status. The pH sensitive layer consists of a graphene oxide (GO) layer obtained by drop-casting 5 μΐ of GO dispersion onto the working electrode of a screen-printed substrate. Sensitivity was 31.8 mV/pH with an accuracy of 0.3 unit of pH. Open-circuit potentiometry was carried out to measure pH in an exudate sample. The GO pH sensor proved to be reliable as the comparison with results obtained from a standard glass electrode pH-meter showed negligible differences (<; 0.09 pH units in the worst case) for measurements performed over a period of 4 days.
Collapse
|
13
|
Potential correlation of wound bed score and biomarkers in chronic lower leg wounds: an exploratory study. J Wound Care 2017; 26:S9-S17. [DOI: 10.12968/jowc.2017.26.sup9.s9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
14
|
Effects of genotype, wilting, and additives on the nutritive value and fermentation of bermudagrass silage. J Anim Sci 2017; 94:3061-71. [PMID: 27482693 DOI: 10.2527/jas.2016-0306] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Bermudagrass is the main warm-season grass species used for livestock production in the southeastern United States; however, when it is ensiled, the silage fermentation parameters are often less than desirable. The objective of this study was to investigate the effects of management practices on the nutritive value and fermentation characteristics of bermudagrass silage. In Exp. 1, treatments were the factorial combinations of 2 bermudagrass genotypes, 'Jiggs' () and 'Tifton 85' ( sp.), 4 additives, and 2 DM concentrations at ensiling. The additives were 1) untreated control (deionized water), 2) Ecosyl, 3) B500, or 4) sugarcane molasses. The 2 DM concentrations at ensiling were low DM (22% DM) or high DM (53% DM). Treatments were replicated 3 times in a completely randomized design. Silage treated with molasses had a lesser ( < 0.05) pH and greater ( < 0.01) lactate concentrations than the control, Ecosyl, and B500 in silage with low DM concentrations and greater ( < 0.01) in vitro true digestibility (IVTD) and lesser ( < 0.01) ADF concentrations than the other treatments at either DM concentration. Silage treated with B500 had the greatest ( < 0.01) aerobic stability, whereas that treated with molasses had the least aerobic stability. However, all treatments presented long aerobic stability (≥150 h). Jiggs had lesser ( < 0.01) ADF and NDF and NDF digestibility (NDFD) concentrations than Tifton 85 and Tifton 85 had greater ( < 0.01) IVTD than Jiggs in the silage with a high DM concentration. In Exp. 2, Jiggs silage treated with either molasses (20 g molasses [DM]/kg forage [as-fed basis]) or nothing (control, untreated silage) was fed to 16 beef heifers ( sp.) in individual drylot pens in a completely randomized design with 8 replicates for voluntary DMI, in vivo apparent DM digestibility, and NDFD evaluations. There were no differences ( = 0.36) among treatments in NDFD; however, there was a trend ( < 0.08) for greater in vivo apparent DM digestibility and DMI in heifers fed the molasses-treated silage. Microbial inoculants had decreased effects on Jiggs and Tifton 85 bermudagrass silage ensiled at a low DM concentration; however, adding molasses was an effective management practice to improve its nutritive value and fermentation characteristics.
Collapse
|
15
|
A breath sampling system assessing the influence of respiratory rate on exhaled breath composition. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:7618-21. [PMID: 26738056 DOI: 10.1109/embc.2015.7320156] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This work presents a computerized system to monitor mouth pressure, tidal volume, exhaled airflow, respiration rate and end-tidal partial pressure of CO2 during breath collection. The system was used to investigate the effect of different respiratory rates on the volatile organic compounds (VOCs) concentrations in exhaled breath. For this purpose, VOCs with well-defined biochemical pathways and different chemical and physical properties were selected as biomarkers related to metabolism (acetone and isopropyl alcohol), cholesterol synthesis (isoprene) and intestinal microflora activity (ethanol). Mixed breath was collected from a nominally healthy volunteer in resting conditions by filling a Nalophan bag. The subject followed a regimented breathing pattern at different respiratory rates (10, 30 and 50 breaths per minute). Results highlight that ventilation pattern strongly influences the concentration of the selected compounds. The proposed system allows exhaled breath to be collected also in patients showing dyspnea such as in case of chronic heart failure, asthma and pulmonary diseases.
Collapse
|
16
|
Serotonin transporter gene polymorphism in eating disorders: Data from a new biobank and META-analysis of previous studies. World J Biol Psychiatry 2016; 17:244-57. [PMID: 26895183 DOI: 10.3109/15622975.2015.1126675] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
UNLABELLED Objectives Growing interest focuses on the association between 5-HTTLPR polymorphism and eating disorders (ED), but published findings have been conflicting. Methods The Italian BIO.VE.D.A. biobank provided 976 samples (735 ED patients and 241 controls) for genotyping. We conducted a literature search of studies published up to 1 April 2015, including studies reporting on 5HTTLPR genotype and allele frequencies in obesity and/or ED. We ran a meta-analysis, including data from BIO.VE.D.A. - comparing low and high-functioning genotype and allele frequencies in ED vs. CONTROLS Results Data from 21 studies, plus BIO.VE.D.A., were extracted providing information from 3,736 patients and 2,707 controls. Neither low- nor high-functioning genotype frequencies in ED patients, with both bi- and tri-allelic models, differed from controls. Furthermore, neither low- nor high-functioning allele frequencies in ED or in BN, in both bi- and triallelic models, differed from control groups. After sensitivity analysis, results were the same in AN vs. CONTROLS Results remained unaltered when investigating recessive and dominant models. Conclusions 5HTTLPR does not seem to be associated with ED in general, or with AN or BN in particular. Future studies in ED should explore the role of ethnicity and psychiatric comorbidity as a possible source of bias.
Collapse
|
17
|
A D-optimal design to model the performances of dressings and devices for negative pressure wound therapy. J Tissue Viability 2016; 25:83-90. [PMID: 26818777 DOI: 10.1016/j.jtv.2016.01.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2015] [Revised: 11/23/2015] [Accepted: 01/04/2016] [Indexed: 10/01/2022]
Abstract
A D-optimal design was used to identify and model variables that affect the transit time of wound exudate through an illustrative dressing used for negative pressure wound therapy. Many authors have addressed the clinical benefits of negative pressure wound therapy, but limited information is available on how to assess performances of dressings. In this paper, the transit time of wound exudate through a dressing was chosen as a model parameter to show how experimental design (DOE) can be used for this purpose. Results demonstrated that rate of exudate production, temperature and dressing thickness were the variables with the largest impact on transit time. The DOE approach could be used to model other dressing properties, like for example capability of absorbing excess exudate or breathability.
Collapse
|
18
|
A dual mode breath sampler for the collection of the end-tidal and dead space fractions. Med Eng Phys 2015; 37:539-44. [PMID: 25922294 DOI: 10.1016/j.medengphy.2015.03.013] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2014] [Revised: 03/17/2015] [Accepted: 03/24/2015] [Indexed: 11/16/2022]
Abstract
This work presents a breath sampler prototype automatically collecting end-tidal (single and multiple breaths) or dead space air fractions (multiple breaths). This result is achieved by real time measurements of the CO2 partial pressure and airflow during the expiratory and inspiratory phases. Suitable algorithms, used to control a solenoid valve, guarantee that a Nalophan(®) bag is filled with the selected breath fraction even if the subject under test hyperventilates. The breath sampler has low pressure drop (<0.5 kPa) and uses inert or disposable components to avoid bacteriological risk for the patients and contamination of the breath samples. A fully customisable software interface allows a real time control of the hardware and software status. The performances of the breath sampler were evaluated by comparing (a) the CO2 partial pressure calculated during the sampling with the CO2 pressure measured off-line within the Nalophan(®) bag; (b) the concentrations of four selected volatile organic compounds in dead space, end-tidal and mixed breath fractions. Results showed negligible deviations between calculated and off-line CO2 pressure values and the distributions of the selected compounds into dead space, end-tidal and mixed breath fractions were in agreement with their chemical-physical properties.
Collapse
|
19
|
|
20
|
Fabrication and functionalization of PCB gold electrodes suitable for DNA-based electrochemical sensing. Biomed Mater Eng 2015; 24:1705-14. [PMID: 24948454 DOI: 10.3233/bme-140982] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The request of high specificity and selectivity sensors suitable for mass production is a constant demand in medical research. For applications in point-of-care diagnostics and therapy, there is a high demand for low cost and rapid sensing platforms. This paper describes the fabrication and functionalization of gold electrodes arrays for the detection of deoxyribonucleic acid (DNA) in printed circuit board (PCB) technology. The process can be implemented to produce efficiently a large number of biosensors. We report an electrolytic plating procedure to fabricate low-density gold microarrays on PCB suitable for electrochemical DNA detection in research fields such as cancer diagnostics or pharmacogenetics, where biosensors are usually targeted to detect a small number of genes. PCB technology allows producing high precision, fast and low cost microelectrodes. The surface of the microarray is functionalized with self-assembled monolayers of mercaptoundodecanoic acid or thiolated DNA. The PCB microarray is tested by cyclic voltammetry in presence of 5 mM of the redox probe K3Fe(CN6) in 0.1 M KCl. The voltammograms prove the correct immobilization of both the alkanethiol systems. The sensor is tested for detecting relevant markers for breast cancer. Results for 5 nM of the target TACSTD1 against the complementary TACSTD1 and non-complementary GRP, MYC, SCGB2A1, SCGB2A2, TOP2A probes show a remarkable detection limit of 0.05 nM and a high specificity.
Collapse
|
21
|
|
22
|
[Relationship between late ventricular potentials and ventricular arrhythmias in patients in chronic dialysis treatment]. Minerva Cardioangiol 1997; 45:155-65. [PMID: 9213830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Arrhythmias are frequent pathology in patients with chronic hemodialysis. We evaluated whether a relatively new technique, signal averaging, could be useful in predicting the development of complex arrhythmias in these patients. METHODS Thirty-three patients, 18 male and 15 female, subjected to thrice weekly chronic hemodialytic treatment with various dialysis techniques, were studied. Exclusion criteria were the presence of antiarrhythmic and inotropic treatment. The following examinations were carried out in all patients: a Holter dynamic electrocardiography for a duration of 24 hours, begun on the day of dialysis, high resolution ECG pre- and post-dialysis to find out if there were any ventricular late potential (VLP). Four hundred beats were examined in order to obtain a background noise of less than 0.7 microV and a better definition of the signal. The following parameters were considered significant for the presence of VLP: a) filtered QRS duration > 120 msec; b) the root mean square of the signal expressed in the terminal portion of QRS (RMS) < 25 microV) high frequency low amplitude signals duration (HFLA) > 40 msec. A positive value in two of these parameters was considered indicative of the presence of VLP. In addition various pre and post-dialysis indices of dialytic efficiency and a mono and two-dimensional echocardiogram with pulsed and color Doppler were carried out. Of the 33 patients studied, ten were excluded because they presented too high a background noise at the high resolution ECG. Of the remaining 23 patients, 13 (56%) presented VLP and nine of these (69%) presented complex arrhythmias. Of the ten patients without VLP, 5 (50%) presented complex arrhythmias. The incidence of arrhythmias was highest during the last two hours of dialysis and in the two hours following it. The patients were then divided into two groups (A and B) according to the ejection fraction (EF) found at the echocardiogram. Group A was composed of 17 patients of whom 8 (47%) presented complex arrhythmias; group B (EF < 45%) was composed of the remaining six patients, who all presented complex arrhythmias. In group A nine patients (53%) out of 17 had LVP, in group B four out of six (66%) had it. All the patients except one presented an increase in the thickness of the ventricular wall and alterations of Doppler transmitral filling rate. Left ventricular hypertrophy was diagnosed in 22 out of the 23 patients. Four patients also had chronic ischaemic heart disease; of these three had LVP. There was no correlation between the presence of LVP and the hemodialytic indices and between the latter and complex arrhythmias. CONCLUSIONS Our study showed that arrhythmias are more frequent in patients with LVP before dialysis than in those without. The difference was statistically significant (p < 0.006); the incidence of arrhythmias was higher in patients with FE < 45% (p < 0.001). The majority of patients (95%) had left ventricular hypertrophy; only four (17%) had ischaemic heart disease too. It is highly probable that the presence of LVP in our patients can be attributed to hypertension and subsequent left ventricular hypertrophy. As patients with LVP at the end of dialysis had a greater incidence of arrhythmias than those without LVP, we suggest that this method could be useful as a first screening in dialysed patients.
Collapse
|
23
|
Planimetry study of the percent of body surface represented by the hand and palm: sizing irregular burns is more accurately done with the palm. THE JOURNAL OF BURN CARE & REHABILITATION 1995; 16:605-6. [PMID: 8582938 DOI: 10.1097/00004630-199511000-00008] [Citation(s) in RCA: 52] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Sizing irregular burns is commonly done with use of the patient's hand as a template representing 1% of the body surface. To verify that this is accurate over a broad range of ages or to see if the surface of the palm is a more consistent template, a planimetry study was done. This revealed that the surface area of the palm averaged 0.52% total body surface area (+/- 0.07) and the palmar surface of the hand 0.85% total body surface area (+/- 0.08). The surface of the palm was a more consistent template and represented 0.5% of the body surface over a broad range of ages.
Collapse
|
24
|
Abstract
The authors report a study of treated prevalence and incidence of schizophrenic and related functional psychoses in an area of northeastern Italy (Portogruaro), based on case-register data. Point, 1-year, and lifetime prevalence as well as incidence rates on the adult population for a broad ICD-9 diagnosis of schizophrenia are given. Data over an 8-year period show the incidence around .2/1000, point prevalence around 1.4, 1-year prevalence of 2.7, and lifetime prevalence around 5.2. The rates peak in the 45 to 64 age group on all measures of prevalence. The implications of these findings are discussed in the light of methodological issues in epidemiological studies of schizophrenia and comparisons are made with figures from other countries.
Collapse
|