A Single Application of Cold Atmospheric Plasma (CAP) Improves Blood Flow Parameters in Chronic Wounds. Microcirculation 2022; 29:e12754. [PMID: 35218286 DOI: 10.1111/micc.12754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Revised: 02/09/2022] [Accepted: 02/21/2022] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To find out if application of cold atmospheric plasma (CAP) affects microcirculation in chronic wounds. METHODS We treated 20 patients with chronic wounds on the lower extremity with CAP. Blood flow parameters of wounds were assessed with combined Laser-Doppler-Flowmetry and spectrophotometry in tissue depth of 2 and 6-8 millimeters. Parameters were assessed under standardized conditions before and over the course of 30 minutes after application of CAP. RESULTS Deep capillary blood flow increased significantly by up to 24.33% (percentage change) after treatment with CAP and remained significantly elevated until the end of measuring period at 30 minutes. Superficial oxygen tissue saturation was significantly elevated by 14.05% for the first 5 minutes after treatment. Postcapillary venous filling pressure was significantly elevated by 10.23% 19 minutes after CAP and stayed significantly elevated starting from minute 24 until the end of measuring. CONCLUSION CAP increases microcirculation parameters in chronic wounds significantly. Since CAP is known for its benefits in wound healing the effects observed may explain the improved healing of chronic wounds after its use. Whether CAP application can increase blood flow in chronic wounds for longer periods of time or boosts blood flow when applied more than once should be subject to further research.
Collapse
|
2
|
Split thickness skin graft versus application of the temporary skin substitute suprathel in the treatment of deep dermal hand burns: a retrospective cohort study of scar elasticity and perfusion. INTERNATIONAL JOURNAL OF BURNS AND TRAUMA 2021; 11:312-320. [PMID: 34557334 PMCID: PMC8449150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Accepted: 06/30/2021] [Indexed: 06/13/2023]
Abstract
Two therapeutic options for deep dermal hand burns are autologous split-thickness skin graft (STSG) following tangential excision and the application of the temporary wound dressing Suprathel following removal of burn blisters. We compared elasticity and perfusion of burn scars after both types of therapy at least one year after completion of treatment. A case series of 80 patients of our department with deep dermal hand burns between 2013 and 2018 was examined in the year 2019 at least one year after completion of treatment (24 females and 56 males with a median age of 47.6 years). The clinical assessment of the scar was performed with the Vancouver Scar Scale (VSS) and Patient and Observer Scar Assessment Scale (POSAS) and the objective assessment with suction cutometry (MPA 580) and an O2C device on both hands. Our statistical analysis showed no statistically significant differences for the R2 and R5 elasticity values between the two types of therapy. The 95% confidence intervals for the ratios of elasticity, and microcirculatory perfusion parameters and scar scale scores of burn scars to respective healthy areas of skin after STSG and Suprathel-therapy mostly covered 1. Subgroup analysis of R2 viscoelasticity and analyses with adjustments for scar compression therapy, nicotine consumption, age, palmar or dorsal localization of the burn scar and interactions of age with smoking and localization gave similar results. The adjusted analysis of SO2 showed statistically significant lower SO2 values, 9% less, after STSG compared to Suprathel treatment. Split-thickness skin graft following tangential excision and the application of Suprathel following removal of burn blisters may be equivalent options for treatment of deep dermal hand burns. To detect possible small differences, further studies with larger samples are required.
Collapse
|
3
|
The repetitive application of cold atmospheric plasma (CAP) improves microcirculation parameters in chronic wounds. Microvasc Res 2021; 138:104220. [PMID: 34216601 DOI: 10.1016/j.mvr.2021.104220] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 06/13/2021] [Accepted: 06/28/2021] [Indexed: 12/15/2022]
Abstract
BACKGROUND Chronic wounds, such as venous leg ulcers, diabetic foot ulcers, and pressure ulcers, impose a significant burden on patients and health care systems worldwide. Cold atmospheric plasma (CAP) accelerates wound healing and decreases bacterial load in chronic wounds in both in vitro and in vivo experiments. For the first time, we examined the effects of a repetitive application of CAP on the microcirculation in chronic wounds. HYPOTHESIS The repetitive application of cold atmospheric plasma application further improves microcirculation in chronic wounds. METHODS Twenty patients with chronic wounds were treated repetitively with CAP. The repetitive application consisted of three CAP sessions, each lasting 90 s and separated by a 10-minute microcirculation measuring period. Microcirculation parameters were assessed with combined Laser-Doppler-Flowmetry and spectrophotometry in a tissue depth of 2 mm. RESULTS Tissue oxygen saturation was significantly increased after the first CAP application. The effect amplitude and duration were further increased after the second and third CAP application with a maximum increase by 16,7% (percent change; p = 0,004 vs. baseline) after the third application. There was no significant increase in capillary blood flow until the third CAP application. After the third CAP application, an increase by 22,6% (p = 0,014) was observed. Postcapillary filling pressure was not significantly increased over the measuring period. The repetitive application of CAP further enhances the microcirculation in chronic wounds compared to a single application. CONCLUSION The repetitive application of CAP boosts and prolongs tissue oxygen saturation and capillary blood flow in chronic wounds compared to a single application. This insight could provide an impetus for new treatment protocols.
Collapse
|
4
|
Cold atmospheric plasma improves cutaneous microcirculation in standardized acute wounds: Results of a controlled, prospective cohort study. Microvasc Res 2021; 138:104211. [PMID: 34144075 DOI: 10.1016/j.mvr.2021.104211] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 06/09/2021] [Accepted: 06/10/2021] [Indexed: 02/08/2023]
Abstract
BACKGROUND Given the high prevalence of wounds and their challenging treatment, the research of therapies to improve wound healing is of great clinical interest. In addition, the general consequences of developing chronic wounds constitute a large health economic aspect, which underscores the interest in the development of efficient treatment strategies. Direct cold atmospheric plasma (di_CAP) has been shown to have beneficial effects on microcirculation of human tissue (Kisch et al., 2016a). It also affects microbial settlements, which may have supportive effects on wound healing processes (Balzer et al., 2015). To treat these adequately, in our view, the positive effects on wound healing should be objectified by application on standardized wounds. However, wound healing is a complex process, depending on nutrient and oxygen supply by cutaneous blood circulation. In spite of microcirculation has been shown to improve in healthy skin by CAP, a quantification of the effect in a standardized wound model has never been evaluated (Kisch et al., 2016a). Based on this, we hypothesize that CAP also influences the microcirculation in standardized acute wounds in a prospective cohort study. METHODS Microcirculatory data of 20 healthy subjects (14 males, 6 females; mean age 40.85 ± 15.84 years; BMI 26.83 ± 7.27 kg/m2) were recorded continuously at a standardized acute wound after skin transplantation (donor site) at the thigh. Under standardized conditions, microcirculatory measurements were performed using a combined laser Doppler and photospectrometry system. After baseline measurement, CAP was applied by a dielectric barrier discharge (DBD) plasma device for 90 s to the acute wound area. Immediately after the application, cutaneous microcirculation was assessed for 30 min (min) at the same site. RESULTS After CAP application, tissue oxygen saturation immediately increased by 5% (92,66 ± 4,76% vs. Baseline 88,21 ± 6,52%, p < 0,01) in the first 60 s and remained significantly elevated for 4 min. Capillary blood flow increased by 19.3% within the first minute of CAP therapy (220.14 ± 65.91 AU vs. Baseline 184.52 ± 56.77 AU, p < 0.001). The statistically highly significant increase in blood flow continued over the entire measurement time. A maximum value was shown in the blood flow in the 15th minute (232.15 ± 58.90 AU, p < 0.001) according to CAP application. With regard to the output measurement, it represents a percentage increase of 25.8%. The measurement of post-capillary venous filling pressure at a tissue depth of 6-8 mm was 59.39 ± AU 12.94 at baseline measurement. After application, there were no significant changes. CONCLUSION CAP increases cutaneous tissue oxygen saturation and capillary blood flow at the standardized acute wound healing model. These results support recently published data on wound healing after CAP treatment. However, further studies are needed to determine if this treatment can improve the reduced microcirculation in chronic wounds. Moreover, repetitive application protocols have to be compared with a single session treatment approach.
Collapse
|
5
|
[10 years of hand traumatology - an epidemiological, structural and economic analysis at a maximum care provider]. HANDCHIR MIKROCHIR P 2021; 53:7-18. [PMID: 33588487 DOI: 10.1055/a-1349-4660] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
BACKGROUND Hand surgery in Germany has been subject to structural changes that strongly affect the balance between medicine and economics. On the one hand there is a shift of elective hand surgery from the inpatient to the outpatient sector. On the other hand - so our observations - emergency hand trauma cases are more concentrated in bigger hospitals. Given this background there is a lack of statistical data on the management of hand trauma care and treatment of patients with hand injuries. This article discusses a 10-year-analysis of hand traumatological cases treated at a maximum care hospital regarding epidemiological, structural and economic aspects. MATERIAL AND METHODS Using a database query using ICD codes, inpatient hand trauma cases were identified between 2009-2018 and analyzed with regard to epidemiological and economic indicators (age, gender, comorbidities, case-mix-index (CMI), revenue, length of stay, length of surgery) using PIVOT tables. Patients under the age of 16 years, forearm fractures and intensive care patients were excluded. RESULTS In the study period the typical hand surgical trauma patient was male with an average age of 44 years. The Patient-Clinical-Complexity-Level (PCCL) was 0 in 80 % of all cases. The proportion of work-related injuries averaged around 25 %. The three top diagnose related groups (DRG) were the I32F (18.5 %), X01B (11.3 %) and the I32A (7.2 %). A striking point was the massive increase in the overall number of trauma cases over the years from approx. 300 cases in 2009 to over 1000 cases per year in 2018 with a shift of the main workload to on-call and night-shift hours away from core working times. In the study period 4 of 5 others hospitals located in a distance of 100 km reduced and stopped treatment of emergency hand cases. The average length of a hospital stay was approx. 4-5 days, the average cut/suture time less than 60 minutes and the average CMI 1.23. Those cases generate an average proceed of € 4370 in 2018, whereby the cases generated by the work-related injuries averaged € 387 less. DISCUSSION On the assumption that the number of emergency hand trauma cases did not really increase in the study period we think that there was a concentration of such cases in a few centres still providing extensive treatment for hand injuries while in smaller hospitals care for emergency hand trauma cases is progressively reduced. However, hand injuries may be worth a second thought for economic reasons because they can create reasonable revenues with rather little effort.If a critical number of patients is exceeded, costs of service provisions can be significantly amortized by the proceed generated by treatment. In those hospitals still taking care for acute hand injuries the workload especially in standby duty increased. What may have a negative input on the numbers of treated elective hand surgery cases.
Collapse
|
6
|
Reversible dilative cardiomyopathy after electrical injury: a case report. J Med Case Rep 2018; 12:333. [PMID: 30404652 PMCID: PMC6223010 DOI: 10.1186/s13256-018-1861-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Accepted: 10/01/2018] [Indexed: 08/30/2023] Open
Abstract
Background Dilative cardiomyopathy is an uncommon cardiac complication of electric shock. Case presentation We report a case of a 12-year-old German boy with a high voltage injury who developed a four-chamber dilative cardiomyopathy, which was diagnosed on the 13th week postburn. One year after the accident, echocardiography showed a normal function of his heart with 64% ejection fraction and normal cavities’ dimensions. Conclusions Despite the fact that dilative cardiomyopathy is not very common in electrical injuries but can be fatal, a prolonged echocardiography follow-up for patients with electrical injury could be recommended. Until now this case is the first child with severe burns after electrocution, who developed a reversible dilative cardiomyopathy.
Collapse
|
7
|
Immediate Dose-Response Effect of High-Energy Versus Low-Energy Extracorporeal Shock Wave Therapy on Cutaneous Microcirculation. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:2975-2982. [PMID: 27662701 DOI: 10.1016/j.ultrasmedbio.2016.08.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Revised: 08/05/2016] [Accepted: 08/08/2016] [Indexed: 06/06/2023]
Abstract
Elucidation of the precise mechanisms and therapeutic options of extracorporeal shock wave therapy (ESWT) is only at the beginning. Although immediate real-time effects of ESWT on cutaneous hemodynamics have recently been described, the dose response to different ESWT energies in cutaneous microcirculation has never been examined. Thirty-nine Sprague-Dawley rats were randomly assigned to three groups that received either focused high-energy shock waves (group A: total of 1000 impulses, 10 J) to the lower leg of the hind limb, focused low-energy shock waves (group B: total of 300 impulses, 1 J) or placebo shock wave treatment (group C: 0 impulses, 0 J) using a multimodality shock wave delivery system (Duolith SD-1 T-Top, Storz Medical, Tägerwilen, Switzerland). Immediate microcirculatory effects were assessed with the O2C (oxygen to see) system (LEA Medizintechnik, Giessen, Germany) before and for 20 min after application of ESWT. Cutaneous tissue oxygen saturation increased significantly higher after high-energy ESWT than after low-energy and placebo ESWT (A: 29.4% vs. B: 17.3% vs. C: 3.3%; p = 0.003). Capillary blood velocity was significantly higher after high-energy ESWT and lower after low-energy ESWT versus placebo ESWT (group A: 17.8% vs. group B: -22.1% vs. group C: -5.0%, p = 0.045). Post-capillary venous filling pressure was significantly enhanced in the high-energy ESWT group in contrast to the low-energy ESWT and placebo groups (group A: 25% vs. group B: 2% vs. group C: -4%, p = 0.001). Both high-energy and low-energy ESWT affect cutaneous hemodynamics in a standard rat model. High-energy ESWT significantly increases parameters of cutaneous microcirculation immediately after application, resulting in higher tissue oxygen saturation, venous filling pressure and blood velocity, which suggests higher tissue perfusion with enhanced oxygen saturation, in contrast to low-energy as well as placebo ESWT. Low-energy ESWT also increased tissue oxygen saturation, albeit to a lower extent, and decreases both blood velocity and venous filling pressure. Low-energy ESWT reduced tissue perfusion, but improved oxygen saturation immediately after the application.
Collapse
|
8
|
Abstract
Bone defects are a very common problem in hand surgery, occurring in bone tumor surgery, in complicated fractures, and in wrist surgery. Bone substitutes may be used instead of autologous bone graft to avoid donor site morbidity. In this article, we will review our experience with the use of Cerament bone void filler (Bonesupport, Lund, Sweden) in elective and trauma hand surgery. A prospective clinical study was conducted with 16 patients treated with this bone graft substitute in our department over a period of 3.5 years. Twelve patients (2 female, 10 male; with an average age of 42.42 years) with monostoic enchondroma of the phalanges were treated and 4 patients (1 female, 3 male; with an average age of 55.25 years) with complicated metacarpal fractures with bone defect. Data such as postoperative course with rating of pain, postoperative complications, functional outcome assessment at 1, 2, 3, 6 months, time to complete remodeling were registered. Postoperative redness and swelling after bone graft substitute use was noticed in 7 patients with enchondroma surgery due to the thin soft-tissue envelope of the fingers. Excellent total active motion of the involved digit was noticed in 10 of 12 enchondroma patients and in all 4 fracture patients at 2-month follow-up. In summary, satisfying results are described, making the use of injectable bone graft substitute in the surgical treatment of enchondromas, as well as in trauma hand surgery a good choice.
Collapse
|
9
|
Repetitive shock wave therapy improves muscular microcirculation. J Surg Res 2016; 201:440-5. [DOI: 10.1016/j.jss.2015.11.049] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2015] [Revised: 10/30/2015] [Accepted: 11/24/2015] [Indexed: 02/06/2023]
|
10
|
Improvement of cutaneous microcirculation by cold atmospheric plasma (CAP): Results of a controlled, prospective cohort study. Microvasc Res 2015; 104:55-62. [PMID: 26655582 DOI: 10.1016/j.mvr.2015.12.002] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2015] [Revised: 12/02/2015] [Accepted: 12/03/2015] [Indexed: 10/22/2022]
Abstract
BACKGROUND Cold atmospheric plasma (CAP) has proven its benefits in the reduction of various bacteria and fungi in both in vitro and in vivo studies. Moreover, CAP generated by dielectric barrier discharge (DBD) promoted wound healing in vivo. Charged particles, chemically reactive species (such as O3, OH, H2O2, O, NxOy), ultraviolet radiation (UV-A and UV-B), strong oscillating electric fields as well as weak electric currents are produced by DBD operated in air. However, wound healing is a complex process, depending on nutrient and oxygen supply via cutaneous blood circulation. Therefore, this study examined the effects of CAP on cutaneous microcirculation in a prospective cohort setting. HYPOTHESIS Cold atmospheric plasma application enhances cutaneous microcirculation. METHODS Microcirculatory data of 20 healthy subjects (11 males, 9 females; mean age 35.2 ± 13.8 years; BMI 24.3 ± 3.1 kg/m(2)) were recorded continuously at a defined skin area at the radial forearm. Under standardized conditions, microcirculatory measurements were performed using a combined laser Doppler and photospectrometry system. After baseline measurement, CAP was applied by a DBD plasma device for 90 s to the same defined skin area of 22.5 cm(2). Immediately after the application cutaneous microcirculation was assessed for 30 min at the same site. RESULTS After CAP application, tissue oxygen saturation immediately increased by 24% (63.8 ± 13.8% from 51.4 ± 13.2% at baseline, p<0.001) and stayed significantly elevated for 8 min. Cutaneous blood flow increased by 73% (41.0 ± 31.2 AU from 23.7 ± 20.8 AU at baseline, p<0.001) and remained upregulated for 11 min. Furthermore, cutaneous blood flow showed two peaks at 14 (29.8 ± 25.0 AU, p=0.049) and 19 min (29.8 ± 22.6 AU, p=0.048) after treatment. Postcapillary venous filling pressure continuously increased, but showed no significant change vs. baseline in the non-specific BMI group. Subgroup analysis revealed that tissue oxygen saturation, postcapillary venous filling pressure and blood flow increased more in case of a lower BMI. CONCLUSION CAP increases cutaneous tissue oxygen saturation and capillary blood flow at the radial forearm of healthy volunteers. These results support recently published data on wound healing after CAP treatment. However, further studies are needed to determine if this treatment can improve the reduced microcirculation in diabetic foot ulcers. Moreover, repetitive application protocols have to be compared with a single session treatment approach.
Collapse
|
11
|
Collection of Wound Exudate From Human Digit Tip Amputations Does Not Impair Regenerative Healing: A Randomized Trial. Medicine (Baltimore) 2015; 94:e1764. [PMID: 26469916 PMCID: PMC4616794 DOI: 10.1097/md.0000000000001764] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
The regrowth of amputated digit tips represents a unique regenerative healing in mammals with subcutaneous volume regrowth, restoration of dactylogram, and suppression of scar formation. Although factor analysis in amphibians and even in mice is easy to obtain, safety of harvesting biomaterial from human digit tip amputations for analysis has not yet been described.The aim of this study was to evaluate if recovering wound exudate does hamper clinical outcome or influence microbiologic or inflammation status.A predefined cohort of 18 patients with fresh digit tip amputations was randomly assigned to receive standard therapy (debridement, occlusive dressing) with (n = 9) or without (n = 9) collection of the whole wound exudate in every dressing change. Primary endpoint (lengthening) and secondary endpoints (regeneration of dactylogram, nail bed and bone healing, time to complete wound closure, scar formation, 2-point discrimination, microbiologic analysis, inflammatory factors interleukin (IL)-1α, tumor necrosis factor-α, IL-4, and IL-6) were determined by an independent, blinded observer.Patients' characteristics showed no significant differences between the groups. All patients completed the study to the end of 3 months follow-up. Exudate collection did not influence primary and secondary endpoints. Furthermore, positive microbiologic findings as well as pus- and necrosis-like appearance neither impaired tissue restoration nor influenced inflammatory factor release.Here, the authors developed an easy and safe protocol for harvesting wound exudate from human digit tip amputations. For the first time, it was shown that harvesting does not impair regenerative healing. Using this method, further studies can be conducted to analyze regeneration associated factors in the human digit tip.DRKS.de Identifier: DRKS00006882 (UTN: U1111-1166-5723).
Collapse
|
12
|
Electrocautery Devices With Feedback Mode and Teflon-Coated Blades Create Less Surgical Smoke for a Quality Improvement in the Operating Theater. Medicine (Baltimore) 2015; 94:e1104. [PMID: 26166102 PMCID: PMC4504583 DOI: 10.1097/md.0000000000001104] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Monopolar electrocautery is a fast and elegant cutting option. However, as it creates surgical smoke containing polycyclic aromatic hydrocarbons (PAHs), it may be hazardous to the health of the surgical team. Although new technologies, such as feedback mode (FM) and Teflon-coated blades (TBs), reduce tissue damage, their impact on surgical smoke creation has not yet been elucidated. Therefore, we analyzed the plume at its source.The aim of this study was to evaluate if electrocautery FM and TBs create less surgical smoke.Porcine tissue containing skin was cut in a standardized manner using sharp-edged Teflon-coated blades (SETBs), normal-shaped TBs, or stainless steel blades (SSBs). Experiments were performed using FM and pure-cut mode. Surgical smoke was sucked through filters or adsorption tubes. Subsequently, filters were scanned and analyzed using a spectrophotometer. A high-performance liquid chromatography (HPLC-UV) was performed to detect benzo[a]pyrene (BaP) and phenanthrene as 2 of the most critical PAHs. Temperature changes at the cutting site were measured by an infrared thermometer.In FM, more surgical smoke was created using SSB compared with TBs (P < 0.001). Furthermore, differences between FM and pure-cut mode were found for SSB and TB (P < 0.001), but not for SETB (P = 0.911). Photometric analysis revealed differences in the peak heights of the PAH spectrum. In HLPC-UV, the amount of BaP and phenanthrene detected was lower for TB compared with SSB. Tissue temperature variations increased when SSB was used in FM and pure-cut mode. Furthermore, different modes revealed higher temperature variations with the use of SETB (P = 0.004) and TB (P = 0.005) during cutting, but not SSB (P = 0.789).We found that the use of both TBs and FM was associated with reduced amounts of surgical smoke created during cutting. Thus, the surgical team may benefit from the adoption of such new technologies, which could contribute to the primary prevention of smoke-related diseases.
Collapse
|
13
|
Epidemiology of pneumonia in a burn care unit: the influence of inhalation trauma on pneumonia and of pneumonia on burn mortality. ANNALS OF BURNS AND FIRE DISASTERS 2015; 28:128-133. [PMID: 27252611 PMCID: PMC4837489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 06/03/2014] [Accepted: 03/04/2015] [Indexed: 06/05/2023]
Abstract
The aim of this study is to determine the epidemiological characteristics of burn patients developing pneumonia, as well as the predisposing factors and the mortality of these patients. Infectious complications present serious problems in severely burned patients. Pneumonia, in particular, is a major cause of morbidity and mortality in burn patients. Patients with inhalation injuries are exposed to a greater risk due to the possible development of infectious complications in the lower respiratory tract. During their stay in our Burn Care Unit, 22.9% of our burn patients developed pneumonia and 10.9 % of these patients died. Risk factors for the development of pneumonia in burn patients were found to be inhalation trauma, high ABSI score, the Baux and modified Baux index, and high ASA score (p<0.01). Age and gender showed no significant correlation to the incidence of pneumonia. In this study we were able to determine the incidence of pneumonia in burn patients, their mortality and the strong correlation of the presence of inhalation injury with the development of pneumonia.
Collapse
|
14
|
Management of difficult intra-articular fractures or fracture dislocations of the proximal interphalangeal joint. J Hand Surg Eur Vol 2015; 40:16-23. [PMID: 25427554 DOI: 10.1177/1753193414559464] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Intra-articular fractures or fracture dislocations of the proximal interphalangeal joint are difficult clinically because the bone and soft tissue structures are small and intricate. Suboptimal treatment of intra-articular fractures typically leads to functional impairment of the hand. This article reviews the current methods of treatment, together with the senior author's experience in treating difficult proximal interphalangeal joint fractures and dislocations. Besides conservative treatments, surgical treatments include open or closed reduction with traditional Osteosynthesis, such as K-wires, screws or plates. Among recent developments are the percutaneous application of thin cannulated compression screws and novel dynamic external fixators. After a preferred minimally invasive treatment with stable reconstruction of the articular surface, sufficient aftercare is necessary to improve surgical outcomes.
Collapse
|
15
|
Prospective clinical study on digital nerve repair with collagen nerve conduits and review of literature. J Reconstr Microsurg 2013; 30:227-34. [PMID: 24338485 DOI: 10.1055/s-0033-1358788] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Little data are available concerning conduit repair of digital nerve lesions. We are presenting a prospective two-center cohort study on digital nerve reconstruction with collagen nerve conduits. The data are put into the context of a comprehensive review of existing literature. Over a period of 3 years, all consecutive digital nerve lesions that could not be repaired by tensionless coaptation with a gap length of less than 26 mm were reconstructed with nerve conduits made from bovine collagen I. Sensibility was assessed 1 week, 3, 6, and 12 months postoperatively by static and moving 2-point-discrimination (2PD) and monofilament testing. Forty-nine digital nerve lesions in 40 patients met the inclusion criteria. The mean nerve gap was 12.3 ± 2.3 mm (span 5-25 mm). Forty nerve reconstructions could be included in the 12-month follow-up. Three cases, assessed 12 months postoperatively, showed excellent sensibility (static 2PD <6 mm). Seventeen achieved good (2PD 6-10 mm), 5 fair (2PD 11-15 mm), 6 poor (2PD >15 mm, but protective sensibility), and 9 achieved no sensibility. Monofilament test results were significantly better if gap length was shorter than 12 mm. Our results confirm tubulization as one possible technique in nerve reconstruction for gap lengths of 5 to 25 mm.
Collapse
|
16
|
Removal of collagen nerve conduits (NeuraGen) after unsuccessful implantation: focus on histological findings. J Reconstr Microsurg 2013; 29:517-22. [PMID: 23818251 DOI: 10.1055/s-0033-1348033] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Nerve conduits are nonneural, hollow tubular structures designed to bridge the gap of a sectioned nerve, to protect the nerve from scar formation, and to guide the regenerating fibers into the distal nerve stump. In the 8-year experience of our department, four patients aged 14 to 50 years had an unsuccessful implantation of a nerve conduit (NeuraGen, Integra, Plainsboro, NJ). In these four patients, the collagen tubes were replaced by an autogenous nerve graft. The histological specimens showed characteristic histological findings of a scar neuroma without any signs of foreign body reaction in three cases and with minimal foreign body reaction in one case. The collagen nerve tube was completely resorbed in all cases after a time period of 6 to 17 months and could not be detected marco- or microscopically.To our knowledge, this is the first report in the English and German literature describing the histological characteristics of explanted collagen nerve tubes in humans.
Collapse
|
17
|
The role of apoptosis and its local/systemic intervention in burns. Burns 2009. [DOI: 10.1016/j.burns.2009.06.135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
18
|
Abstract
The loss of skin has been one of the oldest, yet most frequent and costly problems in our health care system. To restore functional and esthetic integrity in patients with unstable or hypertrophic scars, in burn patients and after skin loss for hereditary, traumatic or oncological reasons, an armamentarium of reconstructive surgical procedures including autogenous, allogenous and xenogenous tissue transfer as well as implantation of alloplastic materials has been favored. For several decades there has been increasing interest focused on 'tissue engineering' of dermal, epidermal and full thickness skin substitutes by both biological and synthetic matrices. At our institution (Hannover Medical School), a collagen/glycosaminoglycan dermal regeneration matrix has been used for immediate dermal coverage after escharectomy in burn injuries as well as for dermal replacement in chronically unstable scars. This article gives an overview on the current state of the art in bioartificial skin as well as our personal experience with the collagen/glycosaminoglycan matrix for dermal replacement in different clinical situations.
Collapse
|
19
|
Abstract
Technetium (99m-Tc)-labelled, polyclonal human immunoglobulin (HIG) has been described as a new agent to detect local infection and inflammation. In this study, we tested 99m-Tc HIG in 55 patients with suspected chronic (n = 42) and acute (n = 13) skeletal infection. Diagnosis was proven operatively (n = 44) and clinically (n = 11), including microbiological culture tests (n = 46). A gamma camera scan was performed 4 and 24 hours after I.v. injection of 500 MBq 99m-Tc-HIG. 99m-Tc-HIG scanning achieved a sensitivity of 91% and a specificity of 93%. We found one false negative and five false positive scintigraphic results in 55 patients. No clinical or biochemical side effects were encountered after 99m-Tc-HIG injection. We recommend this technique especially for localisation of low-grade, chronic osteomyelitis. The mechanisms and kinetics of 99m-Tc-HIG, however, are worth investigating more extensively.
Collapse
|
20
|
Abstract
The hypothesis of whether or not flap perfusion remains persistent through its vascular pedicle up to 10 years after free tissue transfer was tested. Since 1982, more than 1,000 free tissue transfers have been performed at this institution. Of these, 40 patients were selected with comparable posttraumatic soft-tissue defects of the lower leg and surgical repair by a latissimus dorsi myocutaneous free flap. All patients had a postoperative course free of complications. Measurements of flap perfusion were started in groups 1 through 4 (each 10 patients) 3 to 5 weeks, 5 to 7 months, 4 to 6 years, and 8 to 10 years after free tissue transfer, respectively. Quantitative measurements of local flap perfusion were performed by means of the hydrogen clearance technique (Ameda, Switzerland) at definite sites intracutaneously and subcutaneously within the flap's skin paddle as well as in the adjacent intracutaneous and subcutaneous skin of the surrounding soft tissue. Simultaneously, the vascular pedicle of the flap was visualized by a duplex scanner (Toshiba, Japan). In each group nine measurements were performed before (phase A), during (phase B), and after closing the pedicle (phase C) by manual compression. Each measurement took about 10 minutes. Statistical evaluation of the obtained values was achieved by the Mann-Whitney U test and the Wilcoxon signed rank test. Local flap perfusion showed no statistical differences for phase A and C in all four groups of patients. In phase B, however, a statistically highly significant (p < 0.01) absence of local flap perfusion was registered in all four groups at the site of the flap's skin paddle. No statistically significant alterations of intracutaneous and subcutaneous blood flow was found in the surrounding soft tissue. In our clinical-experimental setting, flap perfusion persisted by means of its vascular pedicle even 10 years after free tissue transfer. Our findings support the importance of an intact vascular pedicle for permanent flap survival after free tissue transfer.
Collapse
|
21
|
Postoperative blood flow monitoring after free-tissue transfer by means of the hydrogen clearance technique. Plast Reconstr Surg 1997; 99:493-505. [PMID: 9030160 DOI: 10.1097/00006534-199702000-00027] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The hydrogen clearance technique was introduced for monitoring postoperative blood flow after free-tissue transfer in this prospective clinical study. This technique allows unlimited repeatable quantitative measurements of tissue blood flow in milliliters per minute per 100 gm of tissue at any site including buried flaps. In this study a real-time blood flow measuring system (Ameflow, Ameda, Switzerland) was employed. Two thousand eight hundred and twenty-three blood flow measurements were carried out on 72 free-tissue transfers, which were performed on 71 patients. Nine of these 72 flaps showed vascular complications (12.5 percent), including arterial thrombosis in 6.9 percent (n = 5), hematoma in 4.2 percent (n = 3), and venous thrombosis in 1.4 percent (n = 1). Complications as well as uneventful postoperative cases were monitored correctly by the hydrogen clearance technique in all cases, reaching sensitivity and specificity values of 1.0 for this technique in our study. Furthermore, all complications could be detected earlier by the hydrogen clearance technique than by clinical monitoring alone, which allowed flap salvation in 7 of 9 cases and a resulting permanent failure rate of free-tissue transfer of 2.8 percent (n = 2). From our data we conclude that the hydrogen clearance technique is a promising tool for postoperative blood flow monitoring after free-tissue transfer. For experimental pathophysiologic and pharmacologic studies of tissue blood flow in flaps, further evaluation of our measuring device including comparative studies with other established techniques is highly recommended.
Collapse
|
22
|
Approaches to postoperative blood flow monitoring after free tissue transfer. Which is the best? INT ANGIOL 1995; 14:288-96. [PMID: 8919249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Success rates for free tissue transfer (FTT) have greatly improved over the last 20 years, partly due to improved technical performance of microvascular anastomoses with better optical and instrumental aids. However, flap failure is still a clinical problem and occurs in 5-10%, mainly due to blood vessel thrombosis within the first 24 postoperative hours. Salvation rates of failing FTT can be optimized by the prompt diagnosis of irreversibly compromised tissue blood flow and immediate operative reexploration. Therefore, there is a special demand for adequate and reliable postoperative monitoring techniques. This article gives an overview of all monitoring techniques, which have been performed both in the experimental and clinical setting after FTT thus far.
Collapse
|
23
|
Measurements of tissue blood flow by the hydrogen clearance technique (HCT): a comparative study including laser Doppler flowmetry (LDF) and the Erlangen micro-lightguide spectrophotometer (EMPHO). Microsurgery 1995; 16:808-17. [PMID: 8844663 DOI: 10.1002/micr.1920161208] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The purpose of this study was to compare the hydrogen clearance technique (HCT) with two different, well-established techniques, i.e., the laser Doppler flowmetry (LDF) and the Erlangen micro-lightguide spectrophotometer (EMPHO), for tissue blood flow measurements in an experimental setting. For the animal experiments, we chose a rat model for arterial and venous flap thrombosis, using the epigastric groin flap. Forty male dark Aguty rats were included in the study. The animals were divided into eight groups, each with a different vascular thrombotic model. HCT was used to collect 1,467 measurements, and 2,934 graphs were recorded; 27 measurements (54 graphs) had to be discarded due to faulty electrode placements and electronic noise. In 19 of the 27 discarded measurements the cause of failure was moving of the awaking animal with disruption of the decay signal. The LDF and EMPHO measurements were performed continuously during each measuring phase. Simple and multiple linear regression and paired t-tests were used to compare the three techniques. The reproducibility of registered blood flow values in phases 1, 3, 6 and 7 varied between 7.8% and 13.6% which is in about the same range as LDF and EMPHO. We could not find a significant difference between the three techniques in this regard. The correlation coefficient for HCT and LDF was r = 0.89. For HCT and EMPHO we found r = 0.67. Sensitivity and specificity values for HCT were both 1.0 in detecting arterial and venous flap thrombosis; for LDF we found values of 0.89 and 0.92, respectively. Sensitivity and specificity values for EMPHO were 0.92 and 0.95, respectively. After careful evaluation of three different techniques (HCT, LDF, and EMPHO) for measurements of local tissue blood flow we came to the conclusion that HCT must be favoured as a reliable tool for quantitative measurement of local tissue blood flow and early diagnosis of arterial and venous flap thrombosis.
Collapse
|
24
|
Abstract
The use of laser Doppler flowmetry (LDF) was tested in 108 consecutive patients, who underwent free tissue transfer at our institution between December, 1988, and June, 1990. Sixteen patients (14.8%) suffered vascular complications, which could be detected in all cases earlier by LDF than by clinical examination alone. LDF therefore prompted faster surgical intervention in these cases, allowing flap salvation in 9.3% (n = 10). Difficulties had to be noted in diagnosing venous thrombosis by means of the LDF due to sometimes unspecific alterations in LDF signals. Technical improvement of LDF might lead to a higher diagnostic accuracy if venous thrombosis occurs.
Collapse
|
25
|
Abstract
Ever since free tissue transfer has been established in microsurgery, success rates have greatly improved over the years, partly due to improved technical performance of microvascular anastomoses with better optical and instrumental aids. However, flap failure still occurs in 5-10%, mainly due to blood vessel thrombosis within the first 24 postoperative hours. Salvation rates of failing free tissue transfers can be optimized by in-time diagnosis of irreversibly compromised tissue blood flow and immediate operative reexploration. Therefore, there is a special demand for adequate and reliable postoperative monitoring techniques. This article gives an overview of all monitoring techniques, which have been performed both in the experimental and clinical setting thus far.
Collapse
|