1
|
Lutz JT, Giebler R, Peters J. The 'TEI-index' is preload dependent and can be measured by transoesophageal echocardiography during mechanical ventilation. Eur J Anaesthesiol 2004; 20:872-7. [PMID: 14649338 DOI: 10.1017/s0265021503001406] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND AND OBJECTIVE The Doppler-derived echocardiographic TEI-index, defined as the sum of the left ventricular isovolumic contraction and isovolumic relaxation times divided by ejection time, quantifies combined systolic and diastolic ventricular functions. The index has been proposed to be independent of arterial pressure and heart rate, implying a broad clinical usefulness. However, it is unclear whether the index is preload independent. We assessed whether and to what degree the TEI-index is altered by left ventricular loading conditions, and the feasibility of measurement by transoesophageal echocardiography during anaesthesia and mechanical ventilation. METHODS We studied 17 anaesthetized mechanically ventilated patients with coronary artery disease during variations in left ventricular preload evoked by head-up and head-down tilt, respectively. RESULTS A head-down tilt increasing left ventricular end-diastolic area from 18.8 +/- 4 to 23.7 +/- 4 cm2 (P < 0.05) significantly decreased the TEI-index from 0.5 +/- 0.17 to 0.33 +/- 0.15 (P < 0.05). In contrast, the TEI-index remained unchanged with decreased left ventricular preload (14.4 +/- 3.7 cm2) during head-up tilt. CONCLUSIONS An increase in preload decreases the TEI-index indicating its sensitivity to acute increases in left ventricular preload. The TEI-index can be measured perioperatively by transoesophageal echocardiography.
Collapse
Affiliation(s)
- J T Lutz
- Klinik für Anästhesiologie und Intensivmedizin, Universitätsklinikum Essen, Essen, Germany.
| | | | | |
Collapse
|
2
|
Affiliation(s)
- R Scherer
- Zentrale Abteilung für Anästhesiologie und Intensivmedizin, Evangelisches und Johanniter Klinikum Duisburg/Dinslaken/Oberhausen
| | | |
Collapse
|
3
|
Giebler R, Peters J. [Circulatory mechanics in intra- and extraperitoneal CO2 insufflation in minimally invasive procedures. The effects of a low pressure system]. Anasthesiol Intensivmed Notfallmed Schmerzther 2001; 36:205-12. [PMID: 11386090 DOI: 10.1055/s-2001-12747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
Several studies have addressed the cardiovascular effects of intraperitoneal carbon dioxide insufflation and increased intraabdominal pressure. The pathophysiology of this intervention is complex. Reported results apparently differ depending on which patients are studied and are affected by blood volume and/or positioning. With the Starling resistor concept of abdominal venous return in which, analogous to pulmonary vascular zones, flow through the inferior vena cava is considered a function of the pressure difference between upstream venous and either abdominal pressure or downstream intrathoracic caval vein pressure, different results reported in literature can be reconciled.
Collapse
Affiliation(s)
- R Giebler
- Abteilung für Anästhesiologie und Intensivmedizin Universitätsklinikum Essen.
| | | |
Collapse
|
4
|
Giebler R, Schmidt U, Koch S, Peters J, Scherer R. Combined antithrombin III and C1-esterase inhibitor treatment decreases intravascular fibrin deposition and attenuates cardiorespiratory impairment in rabbits exposed to Escherichia coli endotoxin. Crit Care Med 1999; 27:597-604. [PMID: 10199542 DOI: 10.1097/00003246-199903000-00042] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To assess the effect of a combined antithrombin III and C1-esterase inhibitor treatment on intravascular organ fibrin deposition and cardiorespiratory changes following intravenous Escherichia coli endotoxin (lipopolysaccharide [LPS] 80 microg/kg i.v.) exposure. DESIGN Prospective, randomized trial. SETTING Research laboratory of a university medical center. SUBJECTS Anesthetized, instrumented and mechanically ventilated rabbits ([Chbb:CH); n = 40). INTERVENTIONS Endotoxin was given to 30 animals. Ten animals received no inhibitor (endotoxin control group). The other animals were either treated by high-dose (300 units/kg; n = 10) or low-dose (100 units/kg; n = 10) combined antithrombin III and C1-esterase inhibitor administration. Ten rabbits (time control group) were given placebo (sodium chloride 0.9%). Cardiorespiratory variables were assessed at baseline, 120 mins, and 240 mins after endotoxin or placebo administration. Four hours after endotoxin injection, liver, lung, and kidney tissue samples were examined for intravascular fibrin deposition by light microscopy. MEASUREMENTS AND MAIN RESULTS Inhibitor treatment significantly decreased clot formation in lungs and livers without, however, demonstrating a clear dose-dependent effect. Combined antithrombin III/C1-esterase treatment attenuated the decrease of mean arterial pressure and cardiac output observed following endotoxin injection. Blood pressure improvement was significantly dependent on dosage administered. CONCLUSION Combination of antithrombin III and C1-esterase inhibitor treatment during early endotoxin shock decreased organ fibrin deposition and improved cardiovascular stability.
Collapse
Affiliation(s)
- R Giebler
- Abteilung für Anästhesiologie und Intensivmedizin, Klinikum der Universität-GH Essen, Germany
| | | | | | | | | |
Collapse
|
5
|
Giebler R, Kollenberg B, Pohlen G, Peters J. Effect of positive end-expiratory pressure on the incidence of venous air embolism and on the cardiovascular response to the sitting position during neurosurgery. Br J Anaesth 1998; 80:30-5. [PMID: 9505774 DOI: 10.1093/bja/80.1.30] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
We have studied prospectively the effect of 10 cm H2O of PEEP on the incidence of venous air embolism and on the cardiovascular response to change from the supine to the seated position in a large neurosurgical population. Patients were allocated randomly to receive either PEEP (10 cm H2O, n = 45) or conventional (control, n = 44) ventilation. Cardiovascular and respiratory variables were measured in the supine and sitting positions, and monitoring included precordial Doppler probe, pulmonary artery pressure and expiratory carbon dioxide concentration. Venous air embolism was assumed if changes in precordial Doppler sounds occurred, end-tidal carbon dioxide concentration decreased or air could be retrieved from a central venous multi-orifice catheter. The incidence of venous air embolism (26%) did not differ between patients undergoing conventional ventilation and those undergoing ventilation with 10 cm H2O of PEEP. Venous air embolism was always detected first by alterations in Doppler sounds. Cardiac output was significantly higher in patients undergoing conventional ventilation than in those undergoing ventilation with PEEP in the supine but not in the sitting position. Furthermore, pulmonary vascular resistance increased significantly only in the upright position in those undergoing ventilation with PEEP. The pulmonary artery wedge pressure to central venous pressure gradient did not attain negative values with PEEP or with upright positioning. We conclude that the use of PEEP during neurosurgical procedures performed in the sitting position should be abandoned as it does not decrease the incidence of venous air embolism but is associated with significant adverse cardiovascular effects.
Collapse
Affiliation(s)
- R Giebler
- Abteilung für Anästhesiologie und Intensivmedizin, Universitätsklinikum der Universität-GH Essen, Germany
| | | | | | | |
Collapse
|
6
|
Erhard J, Lange R, Giebler R, Rauen U, de Groot H, Eigler FW. [Auxiliary liver transplantation in urgent and emergency indications]. Langenbecks Arch Chir Suppl Kongressbd 1996; 113:422-4. [PMID: 9101892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
This report will focus on seven patients treated with auxiliary liver transplantation. In two cases the indication was severe metabolic disorder and in five cases a fulminant hepatic failure. The clinical course was highly complicated in both cases with metabolic disorder (the transplant was lost, one patient died), but satisfactory in the patients suffering from fulminant hepatic disease: three of five are off immunosuppression, one is under therapy and one patient died of sepsis in the early phase.
Collapse
Affiliation(s)
- J Erhard
- Abteilung für Allgemeine Chirurgie, Universitätsklinikum Essen
| | | | | | | | | | | |
Collapse
|
7
|
Giebler R, Scherer R, Erhard J, Lange R, Paar D, Stöcker L. [Percutaneous puncture technique for portofemorosubclavicular venovenous bypass in orthotopic liver transplantation]. Anaesthesist 1996; 45:59-65. [PMID: 8678280 DOI: 10.1007/s001010050241] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
UNLABELLED Portofemoro-axillary bypass systems are commonly used to treat adverse haemodynamic effects during the anhepatic phase of orthotopic liver transplantation (OLT). However, low shunt flows may reduce the efficacy of these bypass systems. In order to improve veno-venous bypass management, a percutaneous cannulation technique (PCT) was used to insert large-bore catheters (21 F) into the left femoral and subclavian veins. This study prospectively addresses the complications of the PCT in 195 adult patients undergoing 203 OLTs. METHODS The left femoral and subclavian veins were cannulated preoperatively with 21 F single-lumen catheters (DLP, Grand Rapids, MN, USA) using a Seldinger technique. Intra-operatively, the centrifugal pump (Biopump, Biomedicus, Minnesota, USA) and the portal part of the bypass were connected with the femoral and subclavian catheters. Coagulation profiles, shunt flows, haemodynamic parameters, and complications during OLT associated with the bypass system were recorded. RESULTS Percutaneous cannulation of the left subclavian and femoral veins was successful in 198 (97.6%) patients. Mean portofemoro-subclavian shuntflow was 4.3 (SD 1.3 l min-1). Although cardiac index (shunt 3.91 [SD 1.1] vs pre-shunt 4.42 [SD 1.0] l min-1 m-2, P < 0.05) and oxygen delivery (shunt 496 [SD 111] vs. pre-shunt 562 [SD 153] ml ml-1.m-2, P < 0.05) were not maintained at pre-shunt levels, renal perfusion pressure stayed above 50 mm Hg during the anhepatic phase. Two intra-operative air embolism (0.98%) and one myocardial infarction (0.49%) at the beginning of the anhepatic phase were observed. There were no bleeding complications. CONCLUSIONS The portofemoro-subclavian bypass can be performed by percutaneous cannulation without additional complications in patients undergoing OLT. Although haemorrhagic complications following central venous catheterisation are reported to occur in patients with haemostatic defects, none of them was observed in this study. Two events of air embolism and one cardiac arrest could not be related to the PCT. In conclusion, femoro-subclavian percutaneous cannulation is a simple, rapid, and safe alternative to commonly used veno-venous bypass systems.
Collapse
Affiliation(s)
- R Giebler
- Institut für Anästhesiologie, Universitätsklinikum Essen
| | | | | | | | | | | |
Collapse
|
8
|
Erhard J, Lange R, Giebler R, Rauen U, de Groot H, Eigler FW. Arterialization of the portal vein in orthotopic and auxiliary liver transplantation. A report of three cases. Transplantation 1995; 60:877-9. [PMID: 7482751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/07/2023]
Affiliation(s)
- J Erhard
- Department of General Surgery, University of Essen, Germany
| | | | | | | | | | | |
Collapse
|
9
|
Scherer R, Giebler R, Kampe S, Kox WJ. Effects of hypertonic saline hydroxyethyl starch solution on collagen-induced platelet aggregation and ATP secretion. Infusionsther Transfusionsmed 1994; 21:310-4. [PMID: 7528584 DOI: 10.1159/000223000] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
OBJECTIVE The purpose of this study was to investigate the effect of hypertonic (NaCl 7.5%) hydroxyethyl starch (HES 6%, molecular weight 200,000) (HHES) as used for small-volume resuscitation on global coagulation parameters and platelet function. DESIGN Randomized, controlled clinical trial. SETTING Intraoperative volume loading after induction of general anesthesia. PATIENTS 27 consecutive patients [mean age 59 (22-76) years, mean body weight 69.8 (46-98) kg] undergoing abdominal surgery were studied. INTERVENTIONS Global coagulation tests (aPTT: activated partial thromboplastin time; PT: prothrombin time; platelet count; thrombelastography: TEG), platelet aggregation and ATP release were measured before and 10 min after the application of 4 ml.kg-1 of HHES (study group H, n = 14) or HES (control group C, n = 13). RESULTS The aPTT was prolonged and platelet count was significantly reduced in both study groups. In contrast to the HES group, clot formation time in the TEG was significantly prolonged and the maximum amplitude was reduced in the HHES group. Furthermore, platelet aggregation was significantly slowed down, whereas ATP release significantly increased in the HHES group. CONCLUSION The changes in global coagulation parameters can be explained by dilutional effects of the infused solution. The hyperosmolar saline compound of the HHES solution obviously contributes to the slowing down of platelet aggregation. Osmotic stress and membrane pleating may aggravate HES-induced changes in membrane fluidity and microviscosity and thus explain this impaired interaction. The increase in ATP release suggests a change in receptor-second messenger interaction for delta granule release.
Collapse
Affiliation(s)
- R Scherer
- Institut für Anästhesiologie, Universitätsklinikum, GHS Essen, FRG
| | | | | | | |
Collapse
|
10
|
Scherer R, Erhard J, Giebler R, Lange R, Schmutzler M, Kox WJ. Percutaneous portofemoro-subclavian venovenous bypass during orthotopic liver transplantation. Transplantation 1994; 58:643-4. [PMID: 8091497 DOI: 10.1097/00007890-199409150-00026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
11
|
Scherer R, Giebler R, Erhard J, Lange R, Günnicker M, Schmutzler M, Paar D, Kox WJ. A new method of veno-venous bypass during human orthotopic liver transplantation. Anaesthesia 1994; 49:398-402. [PMID: 8209979 DOI: 10.1111/j.1365-2044.1994.tb03471.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Veno-venous bypass is commonly used during orthotopic liver transplantation, but there is some controversy as to whether it contributes to a better outcome. Low shunt flows frequently reduce the efficacy of portofemoro-axillary systems and so a percutaneous cannulation technique for the subclavian and femoral vein with large bore catheters was developed in order to facilitate bypass management. This study reports the performance and complications of a portofemoro-subclavian bypass system during the anhepatic phase of human orthotopic liver transplantation in 85 patients. A percutaneous cannulation technique and two 7 mm (subclavian and femoral) catheters, inserted pre-operatively, were used in a pump driven portofemoro-subclavian bypass system. Coagulation profiles, shunt flows, haemodynamic parameters, and peri-operative complications associated with bypass were recorded for each patient. Percutaneous cannulation of the left femoral and subclavian vein was successful in 78 patients (91.8%). Mean femoro-subclavian shunt flow was 1.45 l.min-1 (SD 0.37), and mean portofemoro-subclavian flow was 4.28 l.min-1 (SD 1.03). Although oxygen delivery was not maintained at pre-shunt levels (559.7 (SD 147) vs 506 (SD 107) ml.min-1.m-2, p < 0.05) renal perfusion pressure stayed above 50 mmHg (during shunt it was 56 (SD 9) mmHg). One intra-operative air embolism was observed (1.2%), and in one patient a myocardial infarction occurred during the anhepatic phase; neither complication was considered to be related to the percutaneous cannulation technique. There were no bleeding complications. After operation, all chest X rays were normal and clinical examination revealed no adverse effects of portofemoro-subclavian bypass.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- R Scherer
- Institute of Anaesthesiology, University Hospital Essen, Germany
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Scherer R, Giebler R, Schmutzler M, Erhard J, Lange R, Kox WJ. Shuntflow vs renal perfusion pressure during venovenous bypass in human orthotopic liver transplantation. Transplant Proc 1993; 25:2590. [PMID: 8356681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- R Scherer
- Institute of Anesthesiology, University Hospital Essen, Germany
| | | | | | | | | | | |
Collapse
|
13
|
Scherer R, Giebler R, Schmutzler M, Erhard J, Lange R, Kox WJ. Effect of high shuntflows during portofemoro-subclavian venovenous bypass in human orthotopic liver transplantation. Transplant Proc 1993; 25:2591. [PMID: 8356682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- R Scherer
- Institute of Anesthesiology, University Hospital Essen, Germany
| | | | | | | | | | | |
Collapse
|
14
|
Scherer R, Schmutzler M, Giebler R, Erhard J, Stöcker L, Kox WJ. Complications related to thoracic epidural analgesia: a prospective study in 1071 surgical patients. Acta Anaesthesiol Scand 1993; 37:370-4. [PMID: 8322565 DOI: 10.1111/j.1399-6576.1993.tb03731.x] [Citation(s) in RCA: 62] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
In a prospective study, the complications of 1071 patients scheduled for thoracic epidural catheterization for postoperative analgesia (TEA) were studied. All catheters were inserted preoperatively between segment Th 2/3 and Th 11/12 under local anesthesia. Balanced anesthesia with endotracheal intubation and TEA were combined. Postoperatively 389 patients (36.9%) were monitored on a normal surgical ward. Buprenorphine, 0.15 to 0.3 mg, and if needed bupivacaine 0.375% 3-5 ml h-1 were given epidurally. Primary perforation of the dura occurred in 13 patients (1.23%). Radicular pain syndromes were observed in six patients (0.56%). In one patient (0.09%) respiratory depression was seen in close connection with the epidural administration of 0.3 mg buprenorphine. Although 116 patients (10.83%) showed one abnormal clotting parameter but no clinical signs of hemorrhage, there was no complication related to this group. No persisting neurological sequelae caused by the thoracic epidural catheters were found. In conclusion, continuous TEA with buprenorphine for postoperative pain relief after major abdominal surgery is a safe method without too high a risk of catheter-related or drug-induced complications, even on a normal surgical ward and when one clotting parameter is abnormal.
Collapse
Affiliation(s)
- R Scherer
- Institute of Anesthesiology, University Hospital of Essen, Federal Republic of Germany
| | | | | | | | | | | |
Collapse
|
15
|
Scherer R, Giebler R, Erhard J, Lange R, Marichal A, Bredendiek M, Niebel W, Immendorf A. [Porto-femoro-subclavian bypass and the rapid infusion technique in orthotopic liver transplantation]. Anaesthesist 1991; 40:222-8. [PMID: 2058824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Veno-venous bypass during orthotopic liver transplantation is commonly performed as a porto-femoro-axillary bypass. Right-angle positioning of one patient's arm and surgical preparation of the femoral and axillary veins are necessary. In 17 patients and 20 consecutive orthotopic liver transplant procedures the common porto-femoro-axillary veno-venous bypass was substituted by porto-femoro-subclavian bypass with a percutaneous 20 F cannulation set (LAUB catheter, Cook). The 20 F catheter was introduced into the left subclavian vein by Seldinger's technique before the operation and was connected intraoperatively to the outflow tube of the biopump. Surgical preparation of the axillary vein was not performed. In 10 patients a Y-connector was used to connect up the Rapid Infusion System in addition. Postoperatively the catheter was left in place for 2-4 days. Introduction and removal of the catheter were uneventful in all cases. High blood flow through the catheter could be maintained by a low driving pressure of the pump (4000 ml/min; 100 mmHg). No intraoperative complications were observed. Shunt flows remained stable throughout the surgical procedure during the anhepatic stage. There was no bleeding from the puncture site, especially after removal of the catheter, though several patients had a poor coagulatory status in the early postoperative period. Two postoperative complications were observed: air embolism due to disconnection and formation of a thrombus at the catheter tip, which it was possible to remove together with the catheter itself. Installation of an irrigation infusion in the postoperative period and well-tightened connections help avoid such complications as thrombus formation, bleeding or air embolism.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- R Scherer
- Institut für Anaesthesiologie, Universitätsklinikum der GHS Essen
| | | | | | | | | | | | | | | |
Collapse
|