1
|
Inflammatory tissue response in human soft tissue is caused by a higher particle load near carbon fiber-reinforced PEEK compared to titanium plates. Acta Biomater 2024; 180:128-139. [PMID: 38636789 DOI: 10.1016/j.actbio.2024.04.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 03/19/2024] [Accepted: 04/11/2024] [Indexed: 04/20/2024]
Abstract
Titanium as the leading implant material in locked plating is challenged by polymers such as carbon fiber-reinforced polyetheretherketone (CFR-PEEK), which became the focus of interest of researchers and manufacturers in recent years. However, data on human tissue response to these new implant materials are rare. Osteosynthesis plates and peri‑implant soft tissue samples of 16 healed proximal humerus fractures were examined (n = 8 CFR-PEEK, n = 8 titanium). Soft tissue was analyzed by immunohistochemistry and µCT. The entrapped foreign bodies were further examined for their material composition by FTIR. To gain insight into their origin and formation mechanism, explanted and new plates were evaluated by SEM, EDX, profilometry and HR-CT. In the peri‑implant soft tissue of the CFR-PEEK plates, an inflammatory tissue reaction was detected. Tissues contained foreign bodies, which could be identified as tantalum wires, carbon fiber fragments and PEEK particles. Titanium particles were also found in the peri‑implant soft tissue of the titanium plates but showed a less intense surrounding tissue inflammation in immunohistochemistry. The surface of explanted CFR-PEEK plates was rougher and showed exposed and broken carbon fibers as well as protruding and deformed tantalum wires, especially in used screw holes, whereas scratches were identified on the titanium plate surfaces. Particles were present in the peri‑implant soft tissue neighboring both implant materials and could be clearly assigned to the plate material. Particles from both plate materials caused detectable tissue inflammation, with more inflammatory cells found in soft tissue over CFR-PEEK plates than over titanium plates. STATEMENT OF SIGNIFICANCE: Osteosynthesis plates are ubiquitously used in various medical specialties for the reconstruction of bone fractures and defects and are therefore indispensable for trauma surgeons, ENT specialists and many others. The leading implant material are metals such as titanium, but recently implants made of polymers such as carbon fiber-reinforced polyetheretherketone (CFR-PEEK) have become increasingly popular. However, little is known about human tissue reaction and particle generation related to these new implant types. To clarify this question, 16 osteosynthesis plates (n = 8 titanium and n = 8 CFR-PEEK) and the overlying soft tissue were analyzed regarding particle occurrence and tissue inflammation. Tissue inflammation is clinically relevant for the development of scar tissue, which is discussed to cause movement restrictions and thus contributes significantly to patient outcome.
Collapse
|
2
|
Immunomodulation Using BMP-7 and IL-10 to Enhance the Mineralization Capacity of Bone Progenitor Cells in a Fracture Hematoma-Like Environment. Adv Healthc Mater 2024:e2400077. [PMID: 38599586 DOI: 10.1002/adhm.202400077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 03/19/2024] [Indexed: 04/12/2024]
Abstract
Following biomaterial implantation, a failure to resolve inflammation during the formation of a fracture hematoma can significantly limit the biomaterial's ability to facilitate bone regeneration. This study aims to combine the immunomodulatory and osteogenic effects of BMP-7 and IL-10 with the regenerative capacity of collagen-hydroxyapatite (CHA) scaffolds to enhance in vitro mineralization in a hematoma-like environment. Incubation of CHA scaffolds with human whole blood leads to rapid adsorption of fibrinogen, significant stiffening of the scaffold, and the formation of a hematoma-like environment characterized by a limited capacity to support the infiltration of human bone progenitor cells, a significant upregulation of inflammatory cytokines and acute phase proteins, and significantly reduced osteoconductivity. CHA scaffolds functionalized with BMP-7 and IL-10 significantly downregulate the production of key inflammatory cytokines, including IL-6, IL-8, and leptin, creating a more permissive environment for mineralization, ultimately enhancing the biomaterial's osteoconductivity. In conclusion, targeting the onset of inflammation in the early phase of bone healing using BMP-7 and IL-10 functionalized CHA scaffolds is a promising approach to effectively downregulate inflammatory processes, while fostering a more permissive environment for bone regeneration.
Collapse
|
3
|
3D virtual histopathology by phase-contrast X-ray micro-CT for follicular thyroid neoplasms. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; PP:1-1. [PMID: 38437150 DOI: 10.1109/tmi.2024.3372602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/06/2024]
Abstract
Histological analysis is the core of follicular thyroid carcinoma (FTC) classification. The histopathological criteria of capsular and vascular invasion define malignancy and aggressiveness of FTC. Analysis of multiple sections is cumbersome and as only a minute tissue fraction is analyzed during histopathology, under-sampling remains a problem. Application of an efficient tool for complete tissue imaging in 3D would speed-up diagnosis and increase accuracy. We show that X-ray propagation-based imaging (XPBI) of paraffin-embedded tissue blocks is a valuable complementary method for follicular thyroid carcinoma diagnosis and assessment. It enables a fast, non-destructive and accurate 3D virtual histology of the FTC resection specimen. We demonstrate that XPBI virtual slices can reliably evaluate capsular invasions. Then we discuss the accessible morphological information from XPBI and their significance for vascular invasion diagnosis. We show 3D morphological information that allow to discern vascular invasions. The results are validated by comparing XPBI images with clinically accepted histology slides revised by and under supervision of two experienced endocrine pathologists.
Collapse
|
4
|
The influence of implant design and limb alignment on in vivo wear rates of fixed-bearing and rotating-platform knee implant retrievals. J Orthop Res 2023. [PMID: 37975250 DOI: 10.1002/jor.25734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 10/11/2023] [Accepted: 11/14/2023] [Indexed: 11/19/2023]
Abstract
Analysis of polyethylene (PE) wear in knee implants is crucial for understanding the factors leading to revision in total knee arthroplasty. Importantly, current experimental and computational methods for predicting insert wear can only be validated against true in vivo measurements from retrievals. This study quantitatively investigated in vivo PE wear rates in fixed-bearing (FB) (n = 21) and rotating-platform (n = 53) implant retrievals. 3D surface geometry of the retrievals was measured using a structured light scanner. Then, a reference surface that included the deformation, but not the wear that the retrievals had experienced in vivo, was constructed using a fully automatic surface reconstruction algorithm. Finally, wear volume was calculated from the deviation between the worn and reconstructed surfaces. The measurement and analysis techniques were validated and the algorithm was found to produce errors of only 0.2% relative to the component volumes. In addition to quantifying cohort-level wear rates, the effect of mechanical axis limb alignment on mediolateral wear distribution was examined for a subset of the retrievals (n = 14 + 26). Our results show that FB implants produce significantly (p = 0.04) higher topside wear rates (24.6 ± 10.1 mm3 /year) than rotating-platform implants (15.3 ± 8.0 mm3 /year). This effect was larger than that of limb alignment, which had a smaller and nonsignificant influence on overall wear rates (+4.5 ± 11.6 mm3 /year, p = 0.43). However, increased varus alignment was associated significantly with greater medial compartment wear in both the FB and rotating-platform designs (+1.7 ± 1.3%/° and +1.8 ± 1.6%/°). Our findings emphasize the importance of implant design and limb alignment on wear outcomes, providing reference data for improving implant performance and longevity.
Collapse
|
5
|
Multiscale multimodal characterization and simulation of structural alterations in failed bioprosthetic heart valves. Acta Biomater 2023; 169:138-154. [PMID: 37517619 DOI: 10.1016/j.actbio.2023.07.044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 06/30/2023] [Accepted: 07/24/2023] [Indexed: 08/01/2023]
Abstract
Calcific degeneration is the most frequent type of heart valve failure, with rising incidence due to the ageing population. The gold standard treatment to date is valve replacement. Unfortunately, calcification oftentimes re-occurs in bioprosthetic substitutes, with the governing processes remaining poorly understood. Here, we present a multiscale, multimodal analysis of disturbances and extensive mineralisation of the collagen network in failed bioprosthetic bovine pericardium valve explants with full histoanatomical context. In addition to highly abundant mineralized collagen fibres and fibrils, calcified micron-sized particles previously discovered in native valves were also prevalent on the aortic as well as the ventricular surface of bioprosthetic valves. The two mineral types (fibres and particles) were detectable even in early-stage mineralisation, prior to any macroscopic calcification. Based on multiscale multimodal characterisation and high-fidelity simulations, we demonstrate that mineral occurrence coincides with regions exposed to high haemodynamic and biomechanical indicators. These insights obtained by multiscale analysis of failed bioprosthetic valves serve as groundwork for the evidence-based development of more durable alternatives. STATEMENT OF SIGNIFICANCE: Bioprosthetic valve calcification is a well-known clinically significant phenomenon, leading to valve failure. The nanoanalytical characterisation of bioprosthetic valves gives insights into the highly abundant, extensive calcification and disorganization of the collagen network and the presence of calcium phosphate particles previously reported in native cardiovascular tissues. While the collagen matrix mineralisation can be primarily attributed to a combination of chemical and mechanical alterations, the calcified particles are likely of host cellular origin. This work presents a straightforward route to mineral identification and characterization at high resolution and sensitivity, and with full histoanatomical context and correlation to hemodynamic and biomechanical indicators, hence providing design cues for improved bioprosthetic valve alternatives.
Collapse
|
6
|
Quantitative Evaluation of the 3D Anatomy of the Human Osseous Spiral Lamina Using MicroCT. J Assoc Res Otolaryngol 2023; 24:441-452. [PMID: 37407801 PMCID: PMC10504225 DOI: 10.1007/s10162-023-00904-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Accepted: 06/20/2023] [Indexed: 07/07/2023] Open
Abstract
PURPOSE The osseous spiral lamina (OSL) is an inner cochlear bony structure that projects from the modiolus from base to apex, separating the cochlear canal into the scala vestibuli and scala tympani. The porosity of the OSL has recently attracted the attention of scientists due to its potential impact on the overall sound transduction. The bony pillars between the vestibular and tympanic plates of the OSL are not always visible in conventional histopathological studies, so imaging of such structures is usually lacking or incomplete. With this pilot study, we aimed, for the first time, to anatomically demonstrate the OSL in great detail and in 3D. METHODS We measured width, thickness, and porosity of the human OSL by microCT using increasing nominal resolutions up to 2.5-µm voxel size. Additionally, 3D models of the individual plates at the basal and middle turns and the apex were created from the CT datasets. RESULTS We found a constant presence of porosity in both tympanic plate and vestibular plate from basal turn to the apex. The tympanic plate appears to be more porous than vestibular plate in the basal and middle turns, while it is less porous in the apex. Furthermore, the 3D reconstruction allowed the bony pillars that lie between the OSL plates to be observed in great detail. CONCLUSION By enhancing our comprehension of the OSL, we can advance our comprehension of hearing mechanisms and enhance the accuracy and effectiveness of cochlear models.
Collapse
|
7
|
Quantitative laser-matter interaction: a 3D study of UV-fs-laser ablation on single crystalline Ru(0001). OPTICS EXPRESS 2023; 31:17964-17986. [PMID: 37381517 DOI: 10.1364/oe.485713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Accepted: 04/28/2023] [Indexed: 06/30/2023]
Abstract
Laser ablation is nowadays an extensively applied technology to probe the chemical composition of solid materials. It allows for precise targeting of micrometer objects on and in samples, and enables chemical depth profiling with nanometer resolution. An in-depth understanding of the 3D geometry of the ablation craters is crucial for precise calibration of the depth scale in chemical depth profiles. Herein we present a comprehensive study on laser ablation processes using a Gaussian-shaped UV-femtosecond irradiation source and present how the combination of three different imaging methods (scanning electron microscopy, interferometric microscopy, and X-ray computed tomography) can provide accurate information on the crater's shapes. Crater analysis by applying X-ray computed tomography is of considerable interest because it allows the imaging of an array of craters in one step with sub-µm accuracy and is not limited to the aspect ratio of the crater. X-ray computed tomography thereby complements the analysis of laser ablation craters. The study investigates the effect of laser pulse energy and laser burst count on a single crystal Ru(0001) sample. Single crystals ensure that there is no dependence on the grain orientations during the laser ablation process. An array of 156 craters of different dimensions ranging from <20 nm to ∼40 µm in depth were created. For each individually applied laser pulse, we measured the number of ions generated in the ablation plume with our laser ablation ionization mass spectrometer. We show to which extent the combination of these four techniques reveals valuable information on the ablation threshold, the ablation rate, and the limiting ablation depth. The latter is expected to be a consequence of decreasing irradiance upon increasing crater surface area. The ion signal generated was found to be proportional to the volume ablated up to the certain depth, which enables in-situ depth calibration during the measurement.
Collapse
|
8
|
Electromagnetic levitation containerless processing of metallic materials in microgravity: thermophysical properties. NPJ Microgravity 2023; 9:34. [PMID: 37130899 PMCID: PMC10154313 DOI: 10.1038/s41526-023-00281-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Accepted: 04/12/2023] [Indexed: 05/04/2023] Open
Abstract
Transitions from the liquid to the solid state of matter are omnipresent. They form a crucial step in the industrial solidification of metallic alloy melts and are greatly influenced by the thermophysical properties of the melt. Knowledge of the thermophysical properties of liquid metallic alloys is necessary in order to gain a tight control over the solidification pathway, and over the obtained material structure of the solid. Measurements of thermophysical properties on ground are often difficult, or even impossible, since liquids are strongly influenced by earth's gravity. Another problem is the reactivity of melts with container materials, especially at high temperature. Finally, deep undercooling, necessary to understand nucleus formation and equilibrium as well as non-equilibrium solidification, can only be achieved in a containerless environment. Containerless experiments in microgravity allow precise benchmark measurements of thermophysical properties. The electromagnetic levitator ISS-EML on the International Space Station (ISS) offers perfect conditions for such experiments. This way, data for process simulations is obtained, and a deeper understanding of nucleation, crystal growth, microstructural evolution, and other details of the transformation from liquid to solid can be gained. Here, we address the scientific questions in detail, show highlights of recent achievements, and give an outlook on future work.
Collapse
|
9
|
Eliminating Flooding-related Issues in Electrochemical CO₂-to-CO Converters: Two Lines of Defense. Chimia (Aarau) 2023; 77:104-109. [PMID: 38047811 DOI: 10.2533/chimia.2023.104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 01/17/2023] [Indexed: 12/05/2023] Open
Abstract
By using silver (Ag) in nanostructured (nanowire, nanosphere, etc.) or thin-layer form as a catalyst for electrochemical CO2 reduction, very high CO-forming selectivity of almost 100% can be achieved. Supported by gas diffusion layers (GDLs), the reactant CO2 in the gas phase can approach and potentially access active Ag sites, which allows current densities in the range of a few hundred mA cm-2 to be reached. Yet, the stability of gas diffusion electrode (GDE) based electrochemical CO2-to-CO converters is far from perfect, and the activity of GDE cathodes, especially when operated at high current densities, often significantly decays during electrolyses after no more than a few hours. The primary reason of stability losses in GDE-based CO2-to-CO electrolysers is flooding: that is, the excess wetting of the GDE that prevents CO2 from reaching Ag catalytic sites. In the past years, the authors of this paper at Empa and at the University of Bern, cooperating with other partners of the National Competence Center for Research (NCCR) on Catalysis, took different approaches to overcome flooding. While opinions differ with regard to where the first line of defense in protecting GDEs from flooding should lie, a comparison of the recent results of the two groups gives unique insight into the nature of processes occurring in GDE cathodes used for CO2 electrolysis.
Collapse
|
10
|
Spatial heterogeneity of occlusive thrombus in acute ischemic stroke: A systematic review. J Neuroradiol 2023; 50:352-360. [PMID: 36649796 DOI: 10.1016/j.neurad.2023.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 01/12/2023] [Accepted: 01/12/2023] [Indexed: 01/15/2023]
Abstract
Following the advent of mechanical thrombectomy, occlusive clots in ischemic stroke have been amply characterized using conventional histopathology. Many studies have investigated the compositional variability of thrombi and the consequences of thrombus composition on treatment response. More recent evidence has emerged about the spatial heterogeneity of the clot or the preferential distribution of its components and compact nature. Here we review this emerging body of evidence, discuss its potential clinical implications, and propose the development of adequate characterization techniques.
Collapse
|
11
|
Passive climate regulation with transpiring wood for buildings with increased energy efficiency. MATERIALS HORIZONS 2023; 10:257-267. [PMID: 36409220 PMCID: PMC9810104 DOI: 10.1039/d2mh01016j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 11/15/2022] [Indexed: 06/16/2023]
Abstract
Buildings are significant end-users of global energy. About 20% of the energy consumption worldwide is used for maintaining a comfortable indoor climate. Therefore, passive systems for indoor temperature and humidity regulation that can respond to environmental changes are very promising to reduce buildings' energy consumption. We developed a process to improve the responsiveness of wood to humidity changes by laser-drilling microscopic holes and incorporating a hygroscopic salt (calcium chloride). The resulting "transpiring wood" displays superior water adsorption capacity and high moisture exchange rate, allowing regulation of humidity and temperature by the exchange of moisture with the surrounding air. We proved that the hygrothermal performance of transpiring wood can be used to regulate indoor climate, with associated energy savings, for various climate types, thus favoring its application in the building sector. The reduction of temperature fluctuations, thanks to the buffering of temperature peaks, can lead to an indirect energy saving of about 10% for cooling and between 4-27% for heating depending on the climate. Furthermore, our transpiring wood meets different sustainability criteria, from raw materials to the fabrication process, resulting in a product with a low overall environmental impact and that is easy to recycle.
Collapse
|
12
|
Investigations on the Characterization of Various Adhesive Joints by Means of Nanoindentation and Computer Tomography. MATERIALS (BASEL, SWITZERLAND) 2022; 15:8604. [PMID: 36500102 PMCID: PMC9739271 DOI: 10.3390/ma15238604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 11/21/2022] [Accepted: 11/24/2022] [Indexed: 06/17/2023]
Abstract
The mechanical properties of cured wood adhesive films were tested in a dry state by means of nanoindentation. These studies have found that the application of adhesives have an effect on the accuracy of the hardness and elastic modulus determination. The highest values of hardness among the tested adhesives at 20 °C have condensation resins: MF (0.64 GPa) and RPF (0.52 GPa). Then the decreasing EPI (0.43 GPa), PUR (0.23 GPa) and PVAc (0.14 GPa) adhesives. The values of the elastic modulus look a little bit different. The highest values among the tested adhesives at 20 °C have EPI (11.97 GPa), followed by MF (10.54 GPa), RPF (7.98 GPa), PVAc (4.71 GPa) and PUR (3.37 GPa). X-ray micro-computed tomography was used to evaluate the adhesive joint by the determination of the voids. It has been proven that this value depends on the type of adhesive, glue quantity and reactivity. The highest values of the void ratio achieve the PUR (17.26%) adhesives, then PVAc (13.97%), RRF (6.88%), MF (1.78%) and EPI (0.03%). The ratio of the gaps increases with the higher joint thickness. A too high proportion of voids may weaken the adhesive joint.
Collapse
|
13
|
Automated computed tomography based parasitoid detection in mason bee rearings. PLoS One 2022; 17:e0275891. [PMID: 36227883 PMCID: PMC9560145 DOI: 10.1371/journal.pone.0275891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Accepted: 09/23/2022] [Indexed: 11/19/2022] Open
Abstract
In recent years, insect husbandry has seen an increased interest in order to supply in the production of raw materials, food, or as biological/environmental control. Unfortunately, large insect rearings are susceptible to pathogens, pests and parasitoids which can spread rapidly due to the confined nature of a rearing system. Thus, it is of interest to monitor the spread of such manifestations and the overall population size quickly and efficiently. Medical imaging techniques could be used for this purpose, as large volumes can be scanned non-invasively. Due to its 3D acquisition nature, computed tomography seems to be the most suitable for this task. This study presents an automated, computed tomography-based, counting method for bee rearings that performs comparable to identifying all Osmia cornuta cocoons manually. The proposed methodology achieves this in an average of 10 seconds per sample, compared to 90 minutes per sample for the manual count over a total of 12 samples collected around lake Zurich in 2020. Such an automated bee population evaluation tool is efficient and valuable in combating environmental influences on bee, and potentially other insect, rearings.
Collapse
|
14
|
HRXRD and micro-CT investigation of stress and defects induced by a novel packaging design for MEMS sensors. ACTA CRYSTALLOGRAPHICA SECTION A FOUNDATIONS AND ADVANCES 2022. [DOI: 10.1107/s2053273322094724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/19/2023]
|
15
|
Model structures of molten salt-promoted MgO to probe the mechanism of MgCO 3 formation during CO 2 capture at a solid-liquid interface. JOURNAL OF MATERIALS CHEMISTRY. A 2022; 10:16803-16812. [PMID: 36092378 PMCID: PMC9383051 DOI: 10.1039/d2ta02897b] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 07/08/2022] [Indexed: 06/15/2023]
Abstract
MgO is a promising solid oxide-based sorbent to capture anthropogenic CO2 emissions due to its high theoretical gravimetric CO2 uptake and its abundance. When MgO is coated with alkali metal salts such as LiNO3, NaNO3, KNO3, or their mixtures, the kinetics of the CO2 uptake reaction is significantly faster resulting in a 15 times higher CO2 uptake compared to bare MgO. However, the underlying mechanism that leads to this dramatic increase in the carbonation rate is still unclear. This study aims to determine the most favourable location for the nucleation and growth of MgCO3 and more specifically, whether the carbonation occurs preferentially at the buried interface, the triple phase boundary (TPB), and/or inside the molten salt of the NaNO3-MgO system. For this purpose, a model system consisting of a MgO single crystal that is structured by ultra-short pulse laser ablation and coated with NaNO3 as the promoter is used. To identify the location of nucleation and growth of MgCO3, micro X-ray computed tomography, scanning electron microscopy, Raman microspectroscopy and optical profilometry were applied. We found that MgCO3 forms at the NaNO3/MgO interface and not inside the melt. Moreover, there was no preferential nucleation of MgCO3 at the TPB when compared to the buried interface. Furthermore, it is found that there is no observable CO2 diffusion limitation in the nucleation step. However, it was observed that CO2 diffusion limits MgCO3 crystal growth, i.e. the growth rate of MgCO3 is approximately an order of magnitude faster in shallow grooves compared to that in deep grooves.
Collapse
|
16
|
Otosclerosis under microCT: New insights into the disease and its anatomy. FRONTIERS IN RADIOLOGY 2022; 2:965474. [PMID: 37492684 PMCID: PMC10365283 DOI: 10.3389/fradi.2022.965474] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Accepted: 07/13/2022] [Indexed: 07/27/2023]
Abstract
Purpose Otospongiotic plaques can be seen on conventional computed tomography (CT) as focal lesions around the cochlea. However, the resolution remains insufficient to enable evaluation of intracochlear damage. MicroCT technology provides resolution at the single micron level, offering an exceptional amplified view of the otosclerotic cochlea. In this study, a non-decalcified otosclerotic cochlea was analyzed and reconstructed in three dimensions for the first time, using microCT technology. The pre-clinical relevance of this study is the demonstration of extensive pro-inflammatory buildup inside the cochlea which cannot be seen with conventional cone-beam CT (CBCT) investigation. Materials and Methods A radiological and a three-dimensional (3D) anatomical study of an otosclerotic cochlea using microCT technology is presented here for the first time. 3D-segmentation of the human cochlea was performed, providing an unprecedented view of the diseased area without the need for decalcification, sectioning, or staining. Results Using microCT at single micron resolution and geometric reconstructions, it was possible to visualize the disease's effects. These included intensive tissue remodeling and highly vascularized areas with dilated capillaries around the spongiotic foci seen on the pericochlear bone. The cochlea's architecture as a morphological correlate of the otosclerosis was also seen. With a sagittal cut of the 3D mesh, it was possible to visualize intense ossification of the cochlear apex, as well as the internal auditory canal, the modiolus, the spiral ligament, and a large cochleolith over the osseous spiral lamina. In addition, the oval and round windows showed intense fibrotic tissue formation and spongiotic bone with increased vascularization. Given the recently described importance of the osseous spiral lamina in hearing mechanics and that, clinically, one of the signs of otosclerosis is the Carhart notch observed on the audiogram, a tonotopic map using the osseous spiral lamina as region of interest is presented. An additional quantitative study of the porosity and width of the osseous spiral lamina is reported. Conclusion In this study, structural anatomical alterations of the otosclerotic cochlea were visualized in 3D for the first time. MicroCT suggested that even though the disease may not appear to be advanced in standard clinical CT scans, intense tissue remodeling is already ongoing inside the cochlea. That knowledge will have a great impact on further treatment of patients presenting with sensorineural hearing loss.
Collapse
|
17
|
Automated, 3-D and Sub-Micron Accurate Ablation-Volume Determination by Inverse Molding and X-Ray Computed Tomography. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2200136. [PMID: 35521972 PMCID: PMC9284130 DOI: 10.1002/advs.202200136] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 03/25/2022] [Indexed: 06/14/2023]
Abstract
Ablation of materials in combination with element-specific analysis of the matter released is a widely used method to accurately determine a material's chemical composition. Among other methods, repetitive ablation using femto-second pulsed laser systems provides excellent spatial resolution through its incremental removal of nanometer thick layers. The method can be combined with high-resolution mass spectrometry, for example, laser ablation ionization mass spectrometry, to simultaneously analyze chemically the material released. With increasing depth of the volume ablated, however, secondary effects start to play an important role and the ablation geometry deviates substantially from the desired cylindrical shape. Consequently, primarily conical but sometimes even more complex, rather than cylindrical, craters are created. Their dimensions need to be analyzed to enable a direct correlation with the element-specific analytical signals. Here, a post-ablation analysis method is presented that combines generic polydimethylsiloxane-based molding of craters with the volumetric reconstruction of the crater's inverse using X-ray computed tomography. Automated analysis yields the full, sub-micron accurate anatomy of the craters, thereby a scalable and generic method to better understand the fundamentals underlying ablation processes applicable to a wide range of materials. Furthermore, it may serve toward a more accurate determination of heterogeneous material's composition for a variety of applications without requiring time- and labor-intensive analyses of individual craters.
Collapse
|
18
|
Abstract
In the last four years, a multidisciplinary study involving several research groups in Switzerland tackled a number of unsolved, fundamental issues about the alkali-silica reaction (ASR) in concrete. The covered topics include SiO2 dissolution, the characterization of various ASR products formed at different stages of the reaction in both concrete and synthesis, crack formation and propagation. The encompassed scale ranges from nanometers to meters. Apart from conventional techniques, novel methods for the field of ASR have been used, e.g. combination of scanning electron microscopy with dissolution experiments, combination of focused ion beam with transmission electron microscopy, several synchrotron-based methods, synthesis of ASR products for in-depth characterization, time-lapse X-ray micro-tomography combined with contrast-enhancing measures and numerical models of ASR damage based on realistic crack patterns. Key achievements and findings are the quantification of the effect of aluminum on dissolution of different silicates, the variance in morphology and composition of initial ASR products, the differences and similarities between amorphous ASR products and calcium-silicate-hydrate, the link between temperature and the structure of the crystalline ASR products, the behavior of the crystalline ASR products at varying relative humidity, ASR propagation in 4D and numerical modelling based on realistic crack patterns.
Collapse
|
19
|
Author Correction: Non contrast enhanced volumetric histology of blood clots through high resolution propagation-based X-ray microtomography. Sci Rep 2022; 12:3684. [PMID: 35233089 PMCID: PMC8888630 DOI: 10.1038/s41598-022-07806-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
20
|
Principles for an Implementation of a Complete CT Reconstruction Tool Chain for Arbitrary Sized Data Sets and Its GPU Optimization. J Imaging 2022; 8:jimaging8010012. [PMID: 35049853 PMCID: PMC8781919 DOI: 10.3390/jimaging8010012] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 12/23/2021] [Accepted: 01/07/2022] [Indexed: 02/04/2023] Open
Abstract
This article describes the implementation of an efficient and fast in-house computed tomography (CT) reconstruction framework. The implementation principles of this cone-beam CT reconstruction tool chain are described here. The article mainly covers the core part of CT reconstruction, the filtered backprojection and its speed up on GPU hardware. Methods and implementations of tools for artifact reduction such as ring artifacts, beam hardening, algorithms for the center of rotation determination and tilted rotation axis correction are presented. The framework allows the reconstruction of CT images of arbitrary data size. Strategies on data splitting and GPU kernel optimization techniques applied for the backprojection process are illustrated by a few examples.
Collapse
|
21
|
Determination of stress, cracks and defects density in crystals after wafer-bonding processes: a novel HRXRD–X-ray micro-CT conjoint analytical approach. Acta Crystallogr A Found Adv 2021. [DOI: 10.1107/s0108767321090759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
22
|
Determination of stress, cracks and defects density in crystals after wafer-bonding processes: a novel HRXRD–X-ray micro-CT conjoint analytical approach. ACTA CRYSTALLOGRAPHICA SECTION A FOUNDATIONS AND ADVANCES 2021. [DOI: 10.1107/s0108767321091236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
23
|
Optimizing and applying high-resolution, in-line laboratory phase-contrast X-ray imaging for low-density material samples. J Microsc 2020; 282:123-135. [PMID: 33219697 DOI: 10.1111/jmi.12986] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2020] [Revised: 09/24/2020] [Accepted: 11/18/2020] [Indexed: 11/29/2022]
Abstract
In-line, or propagation-based phase-contrast X-ray imaging (PBI) is an attractive alternative to the attenuation-based modality for low-density, soft samples showing low attenuation contrast. With the growing availability of micro- and nano-focus X-ray tubes, the method is increasingly applied in the laboratory. Here, we discuss the technique and demonstrate its advantages for selected low-density, low attenuation material samples using a lab-based micro- and nano-computed tomography systems Easytom XL Ultra, providing micron and sub-micron range resolution PBI images. We demonstrate a multi-step optimization of the lab-based PBI technique on our scanner that includes choosing the optimal detector-source hardware combination available in the setup, then optimizing the imaging geometry and finally the phase retrieval process through a parametric study. We point out and elaborate on the effect of noise correlation and texturing due to phase retrieval. We demonstrate the overall benefits of using the phase image and the phase retrieval for the selected samples such as improved image quality, increased contrast-to-noise ratio while only marginally influencing the spatial resolution. The improvement in image quality also enables further image processing steps for detailed structural analysis of the samples, which would be much more complicated if not impossible based on the transmission image.
Collapse
|
24
|
Responsive Nanofibers with Embedded Hierarchical Lipid Self-Assemblies. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:11787-11797. [PMID: 32936649 DOI: 10.1021/acs.langmuir.0c01487] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
We introduce the design and study of a hybrid electrospun membrane with a dedicated nanoscale structural hierarchy for controlled functions in the biomedical domain. The hybrid system comprises submicrometer-sized internally self-assembled lipid nanoparticles (ISAsomes or mesosomes) embedded into the electrospun membrane with a nanofibrous polymer network. The internal structure of ISAsomes, studied by small-angle X-ray scattering (SAXS) and electron microscopy, demonstrated a spontaneous response to variations in the environmental conditions as they undergo a bicontinuous inverse cubic phase (cubosomes) in solution to a crystalline lamellar phase in the polymer membrane; nevertheless, this phase reorganization is reversible. As revealed by in situ SAXS measurements, if the membrane was put in contact with aqueous media, the cubic phase reappeared and submicrometer-sized cubosomes were released upon dissolution of the nanofibers. Furthermore, the hybrid membranes exhibited a specific anisotropic feature and morphological response under an external strain. While nanofibers were aligned under external strain in the microscale, the semicrystalline domains from the polymer phase were positioned perpendicular to the lamellae of the lipid phase in the nanoscale. The fabricated membranes and their spontaneous responses offer new strategies for the development of structure-controlled functions in electrospun nanofibers for biomedical applications, such as drug delivery or controlled interactions with biointerfaces.
Collapse
|
25
|
Multiscale Analysis of Metal Oxide Nanoparticles in Tissue: Insights into Biodistribution and Biotransformation. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2020; 7:2000912. [PMID: 32775166 PMCID: PMC7404155 DOI: 10.1002/advs.202000912] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 04/22/2020] [Indexed: 05/05/2023]
Abstract
Metal oxide nanoparticles have emerged as exceptionally potent biomedical sensors and actuators due to their unique physicochemical features. Despite fascinating achievements, the current limited understanding of the molecular interplay between nanoparticles and the surrounding tissue remains a major obstacle in the rationalized development of nanomedicines, which is reflected in their poor clinical approval rate. This work reports on the nanoscopic characterization of inorganic nanoparticles in tissue by the example of complex metal oxide nanoparticle hybrids consisting of crystalline cerium oxide and the biodegradable ceramic bioglass. A validated analytical method based on semiquantitative X-ray fluorescence and inductively coupled plasma spectrometry is used to assess nanoparticle biodistribution following intravenous and topical application. Then, a correlative multiscale analytical cascade based on a combination of microscopy and spectroscopy techniques shows that the topically applied hybrid nanoparticles remain at the initial site and are preferentially taken up into macrophages, form apatite on their surface, and lead to increased accumulation of lipids in their surroundings. Taken together, this work displays how modern analytical techniques can be harnessed to gain unprecedented insights into the biodistribution and biotransformation of complex inorganic nanoparticles. Such nanoscopic characterization is imperative for the rationalized engineering of safe and efficacious nanoparticle-based systems.
Collapse
|
26
|
Laser-Engraved Textiles for Engineering Capillary Flow and Application in Microfluidics. ACS APPLIED MATERIALS & INTERFACES 2020; 12:29908-29916. [PMID: 32506905 DOI: 10.1021/acsami.0c03988] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Steering capillary flow in textiles is of great significance in developing affordable and portable microfluidics devices. However, owing to the complex fibrous network, it remains a great challenge to achieve capillary flows with precise filling fronts. Here, an in situ laser engraving route is reported to accurately and rapidly etch textiles for manipulating capillary flow. The heterogeneity of the textile structure is enhanced because of the directional spreading of molten fibers polymer under the control of surface energy minimization. The principle of achieved anisotropic wicking of a water droplet in laser-engraved textiles is proposed. This understanding enables patterning the filling front of a fluid in different shapes, including arrow, straight line, diamond, and annulus. Precise capillary flow in textile-based microfluidics can benefit application in many fields, such as chemical analysis, biological detection, materials synthesis, multiliquid delivery. The laser engraving strategy has the advantages of simplicity, full scalability, and time rapidity, which provides an efficient avenue to steer capillary flow in diverse textiles for manufacturing customized microfluidic devices.
Collapse
|
27
|
Nano-analytical characterization of endogenous minerals in healthy placental tissue: mineral distribution, composition and ultrastructure. Analyst 2020; 144:6850-6857. [PMID: 31591608 DOI: 10.1039/c9an01312a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Despite its crucial role, the placenta is the least understood human organ. Recent clinical studies indicate a direct association between placental calcification and maternal and offspring health. This study reveals distinct characteristics of minerals formed during gestational ageing using cutting-edge nano-analytical characterization and paves the way for investigations focused on the identification of potential markers for disease risks in a clinical setting based on atypical placental mineral fingerprints.
Collapse
|
28
|
Feasibility study of using a compact deuterium-deuterium (D-D) neutron generator for energy-selective transmission tomography. Radiat Phys Chem Oxf Engl 1993 2019. [DOI: 10.1016/j.radphyschem.2018.11.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
29
|
Abstract
We have demonstrated dynamic cold neutron imaging of air-water two-phase flows up to 800 frames per second imaging rates. This has been achieved by using a high-efficiency (relatively thick) scintillator screen in combination with the highest available flux on a continuous spallation source and a high-speed sCMOS camera. This combination renders the spatial resolution to relatively modest value of about 0.5 mm, which is nevertheless sufficient for resolution of bubbles of the size down to about 1.0 mm in motion with unprecedented framerate using neutron imaging. We show the feasibility of the technique on the two-phase flow at ambient temperature and atmospheric pressure conditions, with the foreseen aim of measurements of two phase flows at high-temperatures and high pressures. It is also foreseen that the technique will be further utilized for quantification of the time-resolved instantaneous gas fraction and the gas phase velocity. Demonstration of up to 800 frames per second dynamic cold neutron radiography. Application of such technique for non-periodic (transient) process of bubbly flow in water. Potential for quantification of (i) instantaneous gas volume fraction in dynamic two-phase flow and (ii) instantaneous gas phase velocimetry.
Collapse
|
30
|
Thermal analysis, design, and testing of a rotating beam target for a compact D-D fast neutron generator. Appl Radiat Isot 2018; 145:47-54. [PMID: 30583135 DOI: 10.1016/j.apradiso.2018.12.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Revised: 09/20/2018] [Accepted: 12/06/2018] [Indexed: 11/26/2022]
Abstract
Compact Deuterium-Deuterium fast neutron generators are generally limited to a low neutron yield due to outgassing of implanted deuterium in case of ion beam target overheating. This is even more pronounced for a generator with a small emitting spot tailored to transmission-based imaging applications, resulting in long exposure times. In this work a novel water-cooled rotating copper target rod with a 5 µm thin titanium coating as a deuteron beam target was developed. Using extensive computational fluid dynamics and heat transfer analysis, an optimized target configuration was chosen. The details of the target rod design, construction and loading with deuterium are outlined. The first results after loading showed a peak total neutron output of 4.8 × 107 n/s for -107 kV target high voltage and 0.9 mA average target current at 220 rpm target rotational velocity. The comparison between actual and theoretical ideal neutron yield suggested that no loss of deuterium density in the target due to outgassing occurred.
Collapse
|
31
|
Development of neutron and X-ray imaging techniques for nuclear fuel bundle optimization. NUCLEAR ENGINEERING AND DESIGN 2018. [DOI: 10.1016/j.nucengdes.2017.04.035] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
32
|
Gamma radiography and tomography with a CCD camera and Co-60 source. Appl Radiat Isot 2017; 127:82-86. [DOI: 10.1016/j.apradiso.2017.05.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2017] [Revised: 04/17/2017] [Accepted: 05/09/2017] [Indexed: 11/25/2022]
|
33
|
Investigating the Stability Characteristics of Natural-Circulation Boiling Water Reactors Using Root Loci of a Reduced-Order Model. NUCL TECHNOL 2017. [DOI: 10.13182/nt01-a3247] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
34
|
Experimental Investigation of Natural-Circulation Flow Behavior under Low-Power/Low-Pressure Conditions in the Large-Scale PANDA Facility. NUCL TECHNOL 2017. [DOI: 10.13182/nt04-a3568] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
35
|
|
36
|
Fast neutron radiography and tomography at a 10MW research reactor beamline. Appl Radiat Isot 2016; 119:43-50. [PMID: 27842231 DOI: 10.1016/j.apradiso.2016.10.012] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2016] [Revised: 10/21/2016] [Accepted: 10/22/2016] [Indexed: 11/19/2022]
Abstract
Fast neutron imaging was performed using a beamline of the 10MW research reactor of the Budapest Neutron Centre, Hungary. A simple, low-cost 2D area detector has been used featuring a 8mm thick BC400 plastic scintillator converter screen and a CCD camera. A spatial resolution of around 1.3mm has been achieved. Typically 10min long exposures were needed to obtain reasonable quality radiographic images. For tomographic imaging typically several hours of acquisition were needed to obtain reasonable quality on non-symmetric and larger (e.g. 10×10×10cm3) objects. Due to the presence of a significant gamma background at the experimental position, massive (30cm thick) lead shielding and filtering was applied to the beam. The gamma contribution was mostly baseline independent of the object imaged and therefore could be subtracted, whereas the direct gamma contribution from the beam to the imaging detector signal is estimated to be less than 1%.
Collapse
|
37
|
|
38
|
Time-resolved fast-neutron radiography of air-water two-phase flows in a rectangular channel by an improved detection system. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2015; 86:075103. [PMID: 26233413 DOI: 10.1063/1.4926999] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
In a previous work, we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing, significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size, and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.
Collapse
|
39
|
Development and characterization of a D–D fast neutron generator for imaging applications. Appl Radiat Isot 2015; 96:114-121. [DOI: 10.1016/j.apradiso.2014.11.017] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2014] [Revised: 11/12/2014] [Accepted: 11/21/2014] [Indexed: 10/24/2022]
|
40
|
A novel fast-neutron detector concept for energy-selective imaging and imaging spectroscopy. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:073305. [PMID: 25085132 DOI: 10.1063/1.4890392] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
We present and discuss the operational principle of a new fast-neutron detector concept suitable for either energy-selective imaging or for imaging spectroscopy. The detector is comprised of a series of energy-selective stacks of converter foils immersed in a noble-gas based mixture, coupled to a position-sensitive charge readout. Each foil in the various stacks is made of two layers of different thicknesses, fastened together: a hydrogen-rich (plastic) layer for neutron-to-proton conversion, and a hydrogen-free coating to selectively stop/absorb the recoil protons below a certain energy cut-off. The neutron-induced recoil protons, that escape the converter foils, release ionization electrons in the gas gaps between consecutive foils. The electrons are then drifted towards and localized by a position-sensitive charge amplification and readout stage. Comparison of the images detected by stacks with different energy cut-offs allows energy-selective imaging. Neutron energy spectrometry is realized by analyzing the responses of a sufficient large number of stacks of different energy response and unfolding techniques. In this paper, we present the results of computer simulation studies and discuss the expected performance of the new detector concept. Potential applications in various fields are also briefly discussed, in particularly, the application of energy-selective fast-neutron imaging for nuclear safeguards application, with the aim of determining the plutonium content in Mixed Oxide (MOX) fuels.
Collapse
|
41
|
High-frame rate imaging of two-phase flow in a thin rectangular channel using fast neutrons. Appl Radiat Isot 2014; 90:122-31. [PMID: 24709611 DOI: 10.1016/j.apradiso.2014.03.023] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2014] [Revised: 03/06/2014] [Accepted: 03/16/2014] [Indexed: 11/19/2022]
Abstract
We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hitting a thick Be target. Image sequences down to 10 ms exposure times were obtained using a fast-neutron imaging detector developed in the context of fast-neutron resonance imaging. Different two-phase flow regimes such as bubbly slug and churn flows have been examined. Two phase flow parameters like the volumetric gas fraction, bubble size and mean bubble velocities have been measured. The first results are promising, improvements for future experiments are also discussed.
Collapse
|
42
|
Conceptual design and optimization of a plastic scintillator array for 2D tomography using a compact D-D fast neutron generator. Appl Radiat Isot 2014; 86:63-70. [PMID: 24495568 DOI: 10.1016/j.apradiso.2014.01.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2013] [Revised: 12/20/2013] [Accepted: 01/08/2014] [Indexed: 10/25/2022]
Abstract
A conceptual design optimization of a fast neutron tomography system was performed. The system is based on a compact deuterium-deuterium fast neutron generator and an arc-shaped array of individual neutron detectors. The array functions as a position sensitive one-dimensional detector allowing tomographic reconstruction of a two-dimensional cross section of an object up to 10 cm across. Each individual detector is to be optically isolated and consists of a plastic scintillator and a Silicon Photomultiplier for measuring light produced by recoil protons. A deterministic geometry-based model and a series of Monte Carlo simulations were used to optimize the design geometry parameters affecting the reconstructed image resolution. From this, it is expected that with an array of 100 detectors a reconstructed image resolution of ~1.5mm can be obtained. Other simulations were performed in order to optimize the scintillator depth (length along the neutron path) such that the best ratio of direct to scattered neutron counts is achieved. This resulted in a depth of 6-8 cm and an expected detection efficiency of 33-37%. Based on current operational capabilities of a prototype neutron generator being developed at the Paul Scherrer Institute, planned implementation of this detector array design should allow reconstructed tomograms to be obtained with exposure times on the order of a few hours.
Collapse
|
43
|
Neutron imaging of annular flows in a tight lattice fuel bundle model. NUCLEAR ENGINEERING AND DESIGN 2013. [DOI: 10.1016/j.nucengdes.2013.06.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
44
|
Optimizing the performance of cold-neutron tomography for investigating annular flows and functional spacers in fuel rod bundles. NUCLEAR ENGINEERING AND DESIGN 2013. [DOI: 10.1016/j.nucengdes.2013.03.026] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
45
|
Development of a cold-neutron imaging detector based on thick gaseous electron multiplier. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2013; 84:023305. [PMID: 23464202 DOI: 10.1063/1.4793225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We present the results of our recent studies on a cold-neutron imaging detector prototype based on THick Gaseous Electron Multiplier (THGEM). The detector consists of a thin Boron layer, for neutron-to-charged particle conversion, coupled to two THGEM electrodes in cascade for charge amplification and a position-sensitive charge-readout anode. The detector operates in Ne∕(5%)CF4, at atmospheric pressure, in a stable condition at a gain of around 10(4). Due to the geometrical structure of the detector elements (THGEM geometry and charge read-out anode), the image of detector active area shows a large inhomogeneity, corrected using a dedicated flat-filed correction algorithm. The prototype provides a detection efficiency of 5% and an effective spatial resolution of the order of 1.3 mm.
Collapse
|
46
|
Toward a CFD-grade database addressing LWR containment phenomena. NUCLEAR ENGINEERING AND DESIGN 2012. [DOI: 10.1016/j.nucengdes.2011.08.064] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
47
|
Gas stratification break-up by a vertical jet: Simulations using the GOTHIC code. NUCLEAR ENGINEERING AND DESIGN 2012. [DOI: 10.1016/j.nucengdes.2011.06.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
48
|
Experimental investigation of spray induced gas stratification break-up and mixing in two interconnected vessels. NUCLEAR ENGINEERING AND DESIGN 2011. [DOI: 10.1016/j.nucengdes.2011.07.025] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
49
|
On the relevance of low side flows for thermal loads in T-junctions. NUCLEAR ENGINEERING AND DESIGN 2011. [DOI: 10.1016/j.nucengdes.2011.05.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
50
|
Cold-neutron tomography of annular flow and functional spacer performance in a model of a boiling water reactor fuel rod bundle. NUCLEAR ENGINEERING AND DESIGN 2011. [DOI: 10.1016/j.nucengdes.2011.06.029] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|