1
|
Daly S, Ferreira Fernandes J, Bruggeman E, Handa A, Peters R, Benaissa S, Zhang B, Beckwith JS, Sanders EW, Sims RR, Klenerman D, Davis SJ, O'Holleran K, Lee SF. High-density volumetric super-resolution microscopy. Nat Commun 2024; 15:1940. [PMID: 38431671 PMCID: PMC10908787 DOI: 10.1038/s41467-024-45828-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Accepted: 02/01/2024] [Indexed: 03/05/2024] Open
Abstract
Volumetric super-resolution microscopy typically encodes the 3D position of single-molecule fluorescence into a 2D image by changing the shape of the point spread function (PSF) as a function of depth. However, the resulting large and complex PSF spatial footprints reduce biological throughput and applicability by requiring lower labeling densities to avoid overlapping fluorescent signals. We quantitatively compare the density dependence of single-molecule light field microscopy (SMLFM) to other 3D PSFs (astigmatism, double helix and tetrapod) showing that SMLFM enables an order-of-magnitude speed improvement compared to the double helix PSF by resolving overlapping emitters through parallax. We demonstrate this optical robustness experimentally with high accuracy ( > 99.2 ± 0.1%, 0.1 locs μm-2) and sensitivity ( > 86.6 ± 0.9%, 0.1 locs μm-2) through whole-cell (scan-free) imaging and tracking of single membrane proteins in live primary B cells. We also exemplify high-density volumetric imaging (0.15 locs μm-2) in dense cytosolic tubulin datasets.
Collapse
Affiliation(s)
- Sam Daly
- Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK
| | - João Ferreira Fernandes
- Radcliffe Department of Medicine and MRC Human Immunology Unit, John Radcliffe Hospital, University of Oxford, Oxford, OX3 9DU, UK
| | - Ezra Bruggeman
- Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK
| | - Anoushka Handa
- Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK
| | - Ruby Peters
- Department of Physiology, Development, and Neuroscience, University of Cambridge, Cambridge, CB2 3EL, UK
| | - Sarah Benaissa
- Cambridge Advanced Imaging Centre, Downing Site, University of Cambridge, Cambridge, CB2 3DY, UK
| | - Boya Zhang
- Cambridge Advanced Imaging Centre, Downing Site, University of Cambridge, Cambridge, CB2 3DY, UK
| | - Joseph S Beckwith
- Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK
| | - Edward W Sanders
- Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK
| | - Ruth R Sims
- Wavefront-Engineering Microscopy Group, Photonics Department, Institut de la Vision, Sorbonne Université, INSERM, CNRS, Institut de la Vision, Paris, France
| | - David Klenerman
- Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK
| | - Simon J Davis
- Radcliffe Department of Medicine and MRC Human Immunology Unit, John Radcliffe Hospital, University of Oxford, Oxford, OX3 9DU, UK
| | - Kevin O'Holleran
- Cambridge Advanced Imaging Centre, Downing Site, University of Cambridge, Cambridge, CB2 3DY, UK
| | - Steven F Lee
- Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK.
| |
Collapse
|
2
|
Benaissa S, Cherif-Aouali L, Hany S, Labaki M, Aouad S, Cousin R, Siffert S, Aboukaïs A. Influence of the preparation method and silver content on the nature of active sites in Ag/CeO2 catalysts used for propylene oxidation. Chem Phys 2022. [DOI: 10.1016/j.chemphys.2022.111499] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
3
|
Dehl M, Chelli M, Lippmann S, Benaissa S, Rotari V, Moughabghab M. Results of 115 Rubis II reverse thumb carpometacarpal joint prostheses with a mean follow-up of 10 years. J Hand Surg Eur Vol 2017; 42:592-598. [PMID: 28166695 DOI: 10.1177/1753193416687508] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
UNLABELLED The aim of this study was to assess the clinical and radiological results of the Rubis II thumb carpometacarpal joint reverse prosthesis, at a mean follow-up of 10 years. Between 1997 and 2008, 253 prostheses were implanted in 199 patients; 115 were reviewed. The survival after a mean of 10 years was 89%. At the last follow-up, 70% of prostheses were painless; the others reported moderate or intermittent pain. The satisfaction rate was 98%. The mean opposition was 9 on the Kapandji scale; the mean QuickDASH score was 30. Wrist, key and tip pinch strengths were comparable with the non-operated side. Of the 115 implants, one was radiologically loose (1%) and 15 had suffered dislocations (13%), 12 of which were caused by an injury. Eleven thumbs had revision surgery. This study confirms that the good clinical results of the Rubis II prosthesis are maintained in the medium and long term, and represents a useful alternative to trapeziectomy for selected patients. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- M Dehl
- SOS Mains, Saint Quentin Hospital, Amiens, France
| | - M Chelli
- SOS Mains, Saint Quentin Hospital, Amiens, France
| | - S Lippmann
- SOS Mains, Saint Quentin Hospital, Amiens, France
| | - S Benaissa
- SOS Mains, Saint Quentin Hospital, Amiens, France
| | - V Rotari
- SOS Mains, Saint Quentin Hospital, Amiens, France
| | | |
Collapse
|
6
|
Maes C, Dunaud JL, Moughabghab M, Benaissa S, Henry L, Guériat F. Résultats à plus de cinq ans du traitement de la rhizarthrose par la prothèse Rubis II. À propos de 118 implantations. ACTA ACUST UNITED AC 2010; 29:360-5. [DOI: 10.1016/j.main.2010.09.025] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2009] [Revised: 03/28/2010] [Accepted: 09/26/2010] [Indexed: 10/18/2022]
|
7
|
Gaullier O, Rebaï L, Dunaud JL, Moughabghab M, Benaissa S. [Treatment of fresh humeral diaphysis fractures by Seidel intramedullary locked nailing. A study of 23 initial cases after 2.5 years with rotator cuff evaluation]. Rev Chir Orthop Reparatrice Appar Mot 1999; 85:349-61. [PMID: 10457553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/13/2023]
Abstract
PURPOSE OF THE STUDY The Seidel intramedullary locking nail is one of the alternative methods for operative treatment of humeral shaft fractures. Short follow-up demonstrated persistent pain and stiffness at the shoulder joint. The aims of this retrospective study were first to evaluate results with attention to operative technique, consolidation rate and postoperative complications. Second we studied rotator cuff healing in our first patients. MATERIAL AND METHODS Twenty-five acute diaphyseal fractures were treated between May 91 and Dec 94. We reviewed personally 23 patients with a mean follow-up of 33 months (range 22-66). The dominant fracture type according to AO was type A. Clinical shoulder assessment was carried out using the Constant score. Isometric strength was recorded in both shoulders with a hand-held dynamometer in abduction, external and internal rotation. Sonographic evaluation of the rotator cuff was performed using a 7.5 MHz linear array transducer in all 23 patients. RESULTS All but one fracture healed at an average of two months. Impingement was observed in three patients but pain relief and normal shoulder motion have been reached after nail removal. Infection occurred in one patient but final result was good. Constant score averaged 78.7 (range 51-94.2) classifying the result in all but two patients as excellent or good. Compared with the external and internal rotations, strength was significantly reduced in abduction but reached 83.5 per cent of the opposite shoulder. No statistical differences were found in relation with age, gender and side. Compared with the contralateral shoulder, rotator cuff evaluation with sonography was considered as normal in 18 patients. Calcium deposits of the cuff were noticed in the infected patient. In three cases sonography detected hyperechoic line considered as scar in the supraspinatus tendon without any partial or full-thickness tear. DISCUSSION AND CONCLUSION A median starting point avoids the avascular area and gives a straight access to the medullary canal. This study demonstrates that using this entry portal and a reliable technique antegrade nailing of the humerus does not compromise rotator cuff healing and shoulder function. Technical errors lead to poor or fair results but despite this learning curve, Seidel nail when operative treatment is indicated, is a good choice. Attention must be paid to patients with clinical history of impingement or rotator cuff tendinopathy.
Collapse
Affiliation(s)
- O Gaullier
- Service d'Orthopédie Traumatologie, S.O.S Mains Picardie
| | | | | | | | | |
Collapse
|