Beam control system and output fine-tuning for safe and precise delivery of FLASH radiotherapy at a clinical linear accelerator. Front Oncol 2024; 14:1342488. [PMID: 38304871 PMCID: PMC10830783 DOI: 10.3389/fonc.2024.1342488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 01/03/2024] [Indexed: 02/03/2024] Open
Abstract
Introduction We have previously adapted a clinical linear accelerator (Elekta Precise, Elekta AB) for ultra-high dose rate (UHDR) electron delivery. To enhance reliability in future clinical FLASH radiotherapy trials, the aim of this study was to introduce and evaluate an upgraded beam control system and beam tuning process for safe and precise UHDR delivery. Materials and Methods The beam control system is designed to interrupt the beam based on 1) a preset number of monitor units (MUs) measured by a monitor detector, 2) a preset number of pulses measured by a pulse-counting diode, or 3) a preset delivery time. For UHDR delivery, an optocoupler facilitates external control of the accelerator's thyratron trigger pulses. A beam tuning process was established to maximize the output. We assessed the stability of the delivery, and the independent interruption capabilities of the three systems (monitor detector, pulse counter, and timer). Additionally, we explored a novel approach to enhance dosimetric precision in the delivery by synchronizing the trigger pulse with the charging cycle of the pulse forming network (PFN). Results Improved beam tuning of gun current and magnetron frequency resulted in average dose rates at the dose maximum at isocenter distance of >160 Gy/s or >200 Gy/s, with or without an external monitor chamber in the beam path, respectively. The delivery showed a good repeatability (standard deviation (SD) in total film dose of 2.2%) and reproducibility (SD in film dose of 2.6%). The estimated variation in DPP resulted in an SD of 1.7%. The output in the initial pulse depended on the PFN delay time. Over the course of 50 measurements employing PFN synchronization, the absolute percentage error between the delivered number of MUs calculated by the monitor detector and the preset MUs was 0.8 ± 0.6% (mean ± SD). Conclusion We present an upgraded beam control system and beam tuning process for safe and stable UHDR electron delivery of hundreds of Gy/s at isocenter distance at a clinical linac. The system can interrupt the beam based on monitor units and utilize PFN synchronization for improved dosimetric precision in the dose delivery, representing an important advancement toward reliable clinical FLASH trials.
Collapse
|
2
|
MRI-only radiotherapy from an economic perspective: Can new techniques in prostate cancer treatment be cost saving? Clin Transl Radiat Oncol 2022; 38:183-187. [DOI: 10.1016/j.ctro.2022.11.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 10/16/2022] [Accepted: 11/19/2022] [Indexed: 11/23/2022] Open
|
3
|
FLASH in the Clinic Track FLASH RADIOTHERAPY TREATMENT OF CANINE PATIENTS. Phys Med 2022. [DOI: 10.1016/s1120-1797(22)01446-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
4
|
Volumetric modulated arc therapy dose prediction and deliverable treatment plan generation for prostate cancer patients using a densely connected deep learning model. Phys Imaging Radiat Oncol 2021; 19:112-119. [PMID: 34401537 PMCID: PMC8353474 DOI: 10.1016/j.phro.2021.07.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 07/02/2021] [Accepted: 07/14/2021] [Indexed: 12/30/2022] Open
Abstract
BACKGROUND AND PURPOSE Radiation therapy treatment planning is a manual, time-consuming task that might be accelerated using machine learning algorithms. In this study, we aimed to evaluate if a triplet-based deep learning model can predict volumetric modulated arc therapy (VMAT) dose distributions for prostate cancer patients. MATERIALS AND METHODS A modified U-Net was trained on triplets, a combination of three consecutive image slices and corresponding segmentations, from 160 patients, and compared to a baseline U-Net. Dose predictions from 17 test patients were transformed into deliverable treatment plans using a novel planning workflow. RESULTS The model achieved a mean absolute dose error of 1.3%, 1.9%, 1.0% and ≤ 2.6% for clinical target volume (CTV) CTV_D100%, planning target volume (PTV) PTV_D98%, PTV_D95% and organs at risk (OAR) respectively, when compared to the clinical ground truth (GT) dose distributions. All predicted distributions were successfully transformed into deliverable treatment plans and tested on a phantom, resulting in a passing rate of 100% (global gamma, 3%, 2 mm, 15% cutoff). The dose difference between deliverable treatment plans and GT dose distributions was within 4.4%. The difference between the baseline model and our improved model was statistically significant (p < 0.05) for CVT_D100%, PTV_D98% and PTV_D95%. CONCLUSION Triplet-based training improved VMAT dose distribution predictions when compared to 2D. Dose predictions were successfully transformed into deliverable treatment plans using our proposed treatment planning procedure. Our method may automate parts of the workflow for external beam prostate radiation therapy and improve the overall treatment speed and plan quality.
Collapse
|
5
|
Organ sparing total marrow irradiation compared to total body irradiation prior to allogeneic stem cell transplantation. Eur J Haematol 2021; 107:393-407. [PMID: 34107104 DOI: 10.1111/ejh.13675] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 06/01/2021] [Accepted: 06/07/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVES Total body irradiation (TBI) is commonly used prior to hematopoietic stem cell transplantation (HSCT) in myeloablative conditioning regimens. However, TBI may be replaced by total marrow irradiation (TMI) at centres with access to Helical TomoTherapy, a modality that has the advantage of delivering intensity-modulated radiotherapy to long targets such as the entire bone marrow compartment. Toxicity after organ sparing TMI prior to HSCT has not previously been reported compared to TBI or with regard to engraftment data. METHODS We conducted a prospective observational study on 37 patients that received organ sparing TMI prior to HSCT and compared this cohort to retrospective data on 33 patients that received TBI prior to HSCT. RESULTS The 1-year graft-versus-host disease-free, relapse-free survival (GRFS) was 67.5% for all patients treated with TMI and 80.5% for patients with matched unrelated donor and treated with TMI, which was a significant difference from historical data on TBI patients with a hazard ratio of 0.45 (P = .03) and 0.24 (P < .01). Engraftment with a platelet count over 20 [K/µL] and 50 [K/µL] was significantly shorter for the TMI group, and neutrophil recovery was satisfactory in both treatment cohorts. There was generally a low occurrence of other treatment-related toxicities. CONCLUSIONS Despite small cohorts, some significant differences were found; TMI as part of the myeloablative conditioning yields a high 1-year GRFS, fast and robust engraftment, and low occurrence of acute toxicity.
Collapse
|
6
|
Establishment and Initial Experience of Clinical FLASH Radiotherapy in Canine Cancer Patients. Front Oncol 2021; 11:658004. [PMID: 34055624 PMCID: PMC8155542 DOI: 10.3389/fonc.2021.658004] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Accepted: 04/26/2021] [Indexed: 01/19/2023] Open
Abstract
FLASH radiotherapy has emerged as a treatment technique with great potential to increase the differential effect between normal tissue toxicity and tumor response compared to conventional radiotherapy. To evaluate the feasibility of FLASH radiotherapy in a relevant clinical setting, we have commenced a feasibility and safety study of FLASH radiotherapy in canine cancer patients with spontaneous superficial solid tumors or microscopic residual disease, using the electron beam of our modified clinical linear accelerator. The setup for FLASH radiotherapy was established using a short electron applicator with a nominal source-to-surface distance of 70 cm and custom-made Cerrobend blocks for collimation. The beam was characterized by measuring dose profiles and depth dose curves for various field sizes. Ten canine cancer patients were included in this initial study; seven patients with nine solid superficial tumors and three patients with microscopic disease. The administered dose ranged from 15 to 35 Gy. To ensure correct delivery of the prescribed dose, film measurements were performed prior to and during treatment, and a Farmer-type ion-chamber was used for monitoring. Treatments were found to be feasible, with partial response, complete response or stable disease recorded in 11/13 irradiated tumors. Adverse events observed at follow-up ranging from 3-6 months were mild and consisted of local alopecia, leukotricia, dry desquamation, mild erythema or swelling. One patient receiving a 35 Gy dose to the nasal planum, had a grade 3 skin adverse event. Dosimetric procedures, safety and an efficient clincal workflow for FLASH radiotherapy was established. The experience from this initial study will be used as a basis for a veterinary phase I/II clinical trial with more specific patient inclusion selection, and subsequently for human trials.
Collapse
|
7
|
Correction for Ion Recombination in a Built-in Monitor Chamber of a Clinical Linear Accelerator at Ultra-High Dose Rates. Radiat Res 2021; 194:580-586. [PMID: 33348371 DOI: 10.1667/rade-19-00012] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Accepted: 04/29/2020] [Indexed: 11/03/2022]
Abstract
In the novel and promising radiotherapy technique known as FLASH, ultra-high dose-rate electron beams are used. As a step towards clinical trials, dosimetric advances will be required for accurate dose delivery of FLASH. The purpose of this study was to determine whether a built-in transmission chamber of a clinical linear accelerator can be used as a real-time dosimeter to monitor the delivery of ultra-high-dose-rate electron beams. This was done by modeling the drop-in ion-collection efficiency of the chamber with increasing dose-per-pulse values, so that the ion recombination effect could be considered. The raw transmission chamber signal was extracted from the linear accelerator and its response was measured using radiochromic film at different dose rates/dose-per-pulse values, at a source-to-surface distance of 100 cm. An increase of the polarizing voltage, applied over the transmission chamber, by a factor of 2 and 3, improved the ion-collection efficiency, with corresponding increased efficiency at the highest dose-per-pulse values by a factor 1.4 and 2.2, respectively. The drop-in ion-collection efficiency with increasing dose-per-pulse was accurately modeled using a logistic function fitted to the transmission chamber data. The performance of the model was compared to that of the general theoretical Boag models of ion recombination in ionization chambers. The logistic model was subsequently used to correct for ion recombination at dose rates ranging from conventional to ultra-high, making the transmission chamber useful as a real-time monitor for the dose delivery of FLASH electron beams in a clinical setup.
Collapse
|
8
|
PO-0916: Dose-rate dependence in haematological recovery following total marrow irradiation. Radiother Oncol 2020. [DOI: 10.1016/s0167-8140(21)00933-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
9
|
OC-0461: Acute toxicity and recovery following total marrow irradiation compared to total body irradiation. Radiother Oncol 2020. [DOI: 10.1016/s0167-8140(21)00483-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
10
|
Surface-guided tomotherapy improves positioning and reduces treatment time: A retrospective analysis of 16 835 treatment fractions. J Appl Clin Med Phys 2020; 21:139-148. [PMID: 32592288 PMCID: PMC7484821 DOI: 10.1002/acm2.12936] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 04/20/2020] [Accepted: 05/07/2020] [Indexed: 01/16/2023] Open
Abstract
PURPOSE In this study, we have quantified the setup deviation and time gain when using fast surface scanning for daily setup/positioning with weekly megavoltage computed tomography (MVCT) and compared it to daily MVCT. METHODS A total of 16 835 treatment fractions were analyzed, treated, and positioned using our TomoTherapy HD (Accuray Inc., Madison, USA) installed with a Sentinel optical surface scanning system (C-RAD Positioning AB, Uppsala, Sweden). Patients were positioned using in-room lasers, surface scanning and MVCT for the first three fractions. For the remaining fractions, in-room laser was used for setup followed by daily surface scanning with MVCT once weekly. The three-dimensional (3D) setup correction for surface scanning was evaluated from the registration between MVCT and the planning CT. The setup correction vector for the in-room lasers was assessed from the surface scanning and the MVCT to planning CT registration. The imaging time was evaluated as the time from imaging start to beam-on. RESULTS We analyzed 894 TomoTherapy treatment plans from 2012 to 2018. Of all the treatment fractions performed with surface scanning, 90 % of the residual errors were within 2.3 mm for CNS (N = 284), 2.9 mm for H&N (N = 254), 8.7 mm for thorax (N = 144) and 10.9 for abdomen (N = 134) patients. The difference in residual error between surface scanning and positioning with in-room lasers was significant (P < 0.005) for all sites. The imaging time was assessed as total imaging time per treatment plan, modality, and treatment site and found that surface scanning significantly reduced patient on-couch time compared to MVCT for all treatment sites (P < 0.005). CONCLUSIONS The results indicate that daily surface scanning with weekly MVCT can be used with the current target margins for H&N, CNS, and thorax, with reduced imaging time.
Collapse
|
11
|
MR-PROTECT: Clinical feasibility of a prostate MRI-only radiotherapy treatment workflow and investigation of acceptance criteria. Radiat Oncol 2020; 15:77. [PMID: 32272943 PMCID: PMC7147064 DOI: 10.1186/s13014-020-01513-7] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Accepted: 03/13/2020] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Retrospective studies on MRI-only radiotherapy have been presented. Widespread clinical implementations of MRI-only workflows are however limited by the absence of guidelines. The MR-PROTECT trial presents an MRI-only radiotherapy workflow for prostate cancer using a new single sequence strategy. The workflow incorporated the commercial synthetic CT (sCT) generation software MriPlanner™ (Spectronic Medical, Helsingborg, Sweden). Feasibility of the workflow and limits for acceptance criteria were investigated for the suggested workflow with the aim to facilitate future clinical implementations. METHODS An MRI-only workflow including imaging, post imaging tasks, treatment plan creation, quality assurance and treatment delivery was created with questionnaires. All tasks were performed in a single MR-sequence geometry, eliminating image registrations. Prospective CT-quality assurance (QA) was performed prior treatment comparing the PTV mean dose between sCT and CT dose-distributions. Retrospective analysis of the MRI-only gold fiducial marker (GFM) identification, DVH- analysis, gamma evaluation and patient set-up verification using GFMs and cone beam CT were performed. RESULTS An MRI-only treatment was delivered to 39 out of 40 patients. The excluded patient was too large for the predefined imaging field-of-view. All tasks could successfully be performed for the treated patients. There was a maximum deviation of 1.2% in PTV mean dose was seen in the prospective CT-QA. Retrospective analysis showed a maximum deviation below 2% in the DVH-analysis after correction for rectal gas and gamma pass-rates above 98%. MRI-only patient set-up deviation was below 2 mm for all but one investigated case and a maximum of 2.2 mm deviation in the GFM-identification compared to CT. CONCLUSIONS The MR-PROTECT trial shows the feasibility of an MRI-only prostate radiotherapy workflow. A major advantage with the presented workflow is the incorporation of a sCT-generation method with multi-vendor capability. The presented single sequence approach are easily adapted by other clinics and the general implementation procedure can be replicated. The dose deviation and the gamma pass-rate acceptance criteria earlier suggested was achievable, and these limits can thereby be confirmed. GFM-identification acceptance criteria are depending on the choice of identification method and slice thickness. Patient positioning strategies needs further investigations to establish acceptance criteria.
Collapse
|
12
|
Abstract
OBJECTIVE Recent in vivo results have shown prominent tissue sparing effect of radiotherapy with ultra-high dose rates (FLASH) compared to conventional dose rates (CONV). Oxygen depletion has been proposed as the underlying mechanism, but in vitro data to support this have been lacking. The aim of the current study was to compare FLASH to CONV irradiation under different oxygen concentrations in vitro. METHODS Prostate cancer cells were irradiated at different oxygen concentrations (relative partial pressure ranging between 1.6 and 20%) with a 10 MeV electron beam at a dose rate of either 600 Gy/s (FLASH) or 14 Gy/min (CONV), using a modified clinical linear accelerator. We evaluated the surviving fraction of cells using clonogenic assays after irradiation with doses ranging from 0 to 25 Gy. RESULTS Under normoxic conditions, no differences between FLASH and CONV irradiation were found. For hypoxic cells (1.6%), the radiation response was similar up to a dose of about 5-10 Gy, above which increased survival was shown for FLASH compared to CONV irradiation. The increased survival was shown to be significant at 18 Gy, and the effect was shown to depend on oxygen concentration. CONCLUSION The in vitro FLASH effect depends on oxygen concentration. Further studies to characterize and optimize the use of FLASH in order to widen the therapeutic window are indicated. ADVANCES IN KNOWLEDGE This paper shows in vitro evidence for the role of oxygen concentration underlying the difference between FLASH and CONV irradiation.
Collapse
|
13
|
Implementing safe and robust Total Marrow Irradiation using Helical Tomotherapy - A practical guide. Phys Med 2019; 60:162-167. [PMID: 31000078 DOI: 10.1016/j.ejmp.2019.03.032] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Revised: 03/22/2019] [Accepted: 03/30/2019] [Indexed: 11/16/2022] Open
Abstract
Total Marrow Irradiation (TMI) with Helical Tomotherapy is a radiotherapy treatment technique that targets bone marrow and sanctuary sites prior to stem cell or bone marrow transplantation (SCT/BMT). TMI is a complex procedure that involves several critical steps that all need to be carefully addressed for a successful implementation, such as dose homogeneity in field junctions, choice of target margins, integrity of treatment and back-up planning. In this work we present our solution for a robust and reproducible workflow throughout the treatment chain and data for twenty-three patients treated to date. MATERIAL & METHODS Patients were immobilized in a whole body vacuum cushion and thermoplastic mask. CT-scanning and treatment were performed in two parts with field matching at the upper thigh. Target consisted of marrow containing bone and sanctuary sites. Lungs, kidneys, bowel, heart and liver were defined as organs at risk (OAR). A fast surface scanning system was used to position parts of the body not covered by the imaging system (MVCT) as well as to reduce treatment time. RESULTS All patients completed their treatment and could proceed with SCT/BMT. Doses to OARs were significantly reduced and target dose homogeneity was improved compared to TBI. Robustness tests performed on field matching and patient positioning support that the field junction technique is adequate. Replacing MVCT with optical surface scanning reduced the treatment time by 25 min per fraction. CONCLUSION The methodology presented here has shown to provide a safe, robust and reproducible treatment for Total Marrow Irradiation using Tomotherapy.
Collapse
|
14
|
Modifying a clinical linear accelerator for delivery of ultra-high dose rate irradiation. Radiother Oncol 2019; 139:40-45. [PMID: 30755324 DOI: 10.1016/j.radonc.2019.01.031] [Citation(s) in RCA: 99] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2018] [Revised: 01/24/2019] [Accepted: 01/25/2019] [Indexed: 12/31/2022]
Abstract
OBJECTIVES The purpose of this study was to modify a clinical linear accelerator, making it capable of electron beam ultra-high dose rate (FLASH) irradiation. Modifications had to be quick, reversible, and without interfering with clinical treatments. METHODS Performed modifications: (1) reduced distance with three setup positions, (2) adjusted/optimized gun current, modulator charge rate and beam steering values for a high dose rate, (3) delivery was controlled with a microcontroller on an electron pulse level, and (4) moving the primary and/or secondary scattering foils from the beam path. RESULTS The variation in dose for a five-pulse delivery was measured to be 1% (using a diode, 4% using film) during 10 minutes after a warm-up procedure, later increasing to 7% (11% using film). A FLASH irradiation dose rate was reached at the cross-hair foil, MLC, and wedge position, with ≥30, ≥80, and ≥300 Gy/s, respectively. Moving the scattering foils resulted in an increased output of ≥120, ≥250, and ≥1000 Gy/s, at the three positions. The beam flatness was 5% at the cross-hair position for a 20 × 20 and a 10 × 10 cm2 area, with and without both scattering foils in the beam. The beam flatness was 10% at the wedge position for a 6 and 2.5 cm diametric area, with and without the scattering foils in the beam path. CONCLUSIONS A clinical accelerator was modified to produce ultra-high dose rates, high enough for FLASH irradiation. Future work aims to fine-tune the dose delivery, using the on-board transmission chamber signal and adjusting the dose-per-pulse.
Collapse
|
15
|
EP-2193: Clinical implementation of MR-only prostate radiotherapy excluding CT. Radiother Oncol 2018. [DOI: 10.1016/s0167-8140(18)32502-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
16
|
|
17
|
PO-0845: Evaluation of interplay effects of target and MLC during VMAT by using 3D gel measurements. Radiother Oncol 2013. [DOI: 10.1016/s0167-8140(15)33151-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
18
|
EP-1417 IPAD AND ANDROID TABLETS FOR ONLINE INTRA- & INTER-INSTITUTIONAL COMPARISONS OF INDEPENDENT DOSE CALCULATIONS. Radiother Oncol 2012. [DOI: 10.1016/s0167-8140(12)71750-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
19
|
1098 poster DYNAMIC MODELLING OF THE DOSE RESPONSE OF POLYMER GEL DOSIMETERS. Radiother Oncol 2011. [DOI: 10.1016/s0167-8140(11)71220-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
20
|
1210 poster BREATHING ADAPTED RADIOTHERAPY USING OPTICAL REALTIME THORACIC LOCALIZATION. Radiother Oncol 2011. [DOI: 10.1016/s0167-8140(11)71332-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
21
|
1559 poster MIGRATION OF DOSE CALCULATION ALGORITHM FROM PBC TO AAA FOR STEREOTACTIC LUNG CANCER TREATMENT PLANNING. Radiother Oncol 2011. [DOI: 10.1016/s0167-8140(11)71681-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
22
|
1255 poster PATIENT MONITORING DURING TREATMENT USING SENTINEL LASER SCANNING SYSTEM. Radiother Oncol 2011. [DOI: 10.1016/s0167-8140(11)71377-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
23
|
Matrilysin expression related to radiation and microflora changes in murine bowel. J Surg Res 2011; 167:e137-43. [PMID: 21324398 DOI: 10.1016/j.jss.2010.12.031] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2010] [Revised: 12/07/2010] [Accepted: 12/20/2010] [Indexed: 12/14/2022]
Abstract
BACKGROUND Matrilysin (MMP-7) elevation after radiotherapy is shown in humans. Matrilysin regulates certain cytokines and the production of bactericidal proteins when the mucosa is exposed to bacterial antigens. We investigate the effect of irradiation on matrilysin and microflora in murine bowel, after modulation with antibiotics. METHODS Animals were divided into two different groups a radiation group (72 animals) and sham radiation group (36 animals). Animals were divided into smaller groups of six according to radiation dose (19 or 38 Gy or sham). Seven days before radiotherapy ampicillin 500 mg/kg/d was administered intramuscularly, in the antibiotic groups. An exteriorized segment of ileum was subjected to single high dose radiation (19 or 38 Gy). Samples were collected 2, 24, and 48 h and analyzed for microflora, MIP-2, TGF-β, and MMP-7. RESULTS The combination of antibiotics and irradiation leads to an early significant reduction of bacteria, down-regulates MIP-2, up-regulates TGF-β and elevation of MMP-7 to levels achieved by antibiotics or irradiation alone. Lactobacilli were reduced to non-existent levels after antibiotics. CONCLUSIONS Pretreatment with Ampicillin before irradiation and laparotomy in a murine model leads to Matrilysin over-expression as achieved by radiotherapy alone. Microfloral regulation does not affect MMP-7 stimulation after surgical or radiological trauma. Radiotherapy overrides the effect of antibiotics leading to an up-regulation of MMP-7, TGF-β and MIP-2 expression between 24 h and 48 h.
Collapse
|
24
|
A STATISTICAL METHOD FOR EVALUATION AND COMPARISON OF DOSE DISTRIBUTIONS IN EXTER NAL RADIOTHERAPY. Radiother Oncol 2009. [DOI: 10.1016/s0167-8140(12)72769-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
25
|
Local radiotherapy of exposed murine small bowel: apoptosis and inflammation. BMC Surg 2008; 8:1. [PMID: 18173838 PMCID: PMC2248567 DOI: 10.1186/1471-2482-8-1] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2007] [Accepted: 01/03/2008] [Indexed: 12/15/2022] Open
Abstract
Background Preoperative radiotherapy of the pelvic abdomen presents with complications mostly affecting the small bowel. The aim of this study was to define the features of early radiation-induced injury on small bowel. Methods 54 mice were divided into two groups (36 irradiated and 18 sham irradiated). Animals were placed on a special frame and (in the radiated group) the exteriorized segment of ileum was subjected to a single absorbed dose of 19 or 38 Gy radiation using 6 MV high energy photons. Specimens were collected for histology, immunohistochemistry (IHC) and ELISA analysis after 2, 24 and 48 hours. Venous blood was collected for systemic leucocyte count in a Burker chamber. Results Histology demonstrated progressive infiltration of inflammatory cells with cryptitis and increased apoptosis. MIP-2 (macrophage inflammatory protein) concentration was significantly increased in irradiated animals up to 48 hours. No significant differences were observed in IL-10 (interleukin) and TNF-α (tumour necrosis factor) levels. IHC with CD45 showed a significant increase at 2 hours of infiltrating leucocytes and lymphocytes after irradiation followed by progressive decrease with time. Caspase-3 expression increased significantly in a dose dependent trend in both irradiated groups up to 48 hours. Conclusion Acute small bowel injury caused by local irradiation is characterised by increased apoptosis of crypt epithelial cells and by lymphocyte infiltration of the underlying tissue. The severity of histological changes tends to be dose dependent and may affect the course of tissue damage.
Collapse
|
26
|
256 A low-density normoxic polymer gel dosimeter: Basic studies. Radiother Oncol 2005. [DOI: 10.1016/s0167-8140(05)81233-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
27
|
Radiation enteropathy and leucocyte-endothelial cell reactions in a refined small bowel model. BMC Surg 2004; 4:10. [PMID: 15363103 PMCID: PMC522820 DOI: 10.1186/1471-2482-4-10] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2004] [Accepted: 09/13/2004] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Leucocyte recruitment and inflammation are key features of high dose radiation-induced tissue injury. The inflammatory response in the gut may be more pronounced following radiotherapy due to its high bacterial load in comparison to the response in other organs. We designed a model to enable us to study the effects of radiation on leucocyte-endothelium interactions and on intestinal microflora in the murine ileum. This model enables us to study specifically the local effects of radiation therapy. METHOD A midline laparotomy was performed in male C57/Bl6 mice and a five-centimetre segment of ileum is irradiated using the chamber. Leucocyte responses (rolling and adhesion) were then analysed in ileal venules 2 - 48 hours after high dose irradiation, made possible by an inverted approach using intravital fluorescence microscopy. Furthermore, intestinal microflora, myeloperoxidase (MPO) and cell histology were analysed. RESULTS The highest and most reproducible increase in leucocyte rolling was exhibited 2 hours after high dose irradiation whereas leucocyte adhesion was greatest after 16 hours. Radiation reduced the intestinal microflora count compared to sham animals with a significant decrease in the aerobic count after 2 hours of radiation. Further, the total aerobic counts, Enterobacteriaceae and Lactobacillus decreased significantly after 16 hours. In the radiation groups, the bacterial count showed a progressive increase from 2 to 24 hours after radiation. CONCLUSION This study presents a refinement of a previous method of examining mechanisms of radiation enteropathy, and a new approach at investigating radiation induced leucocyte responses in the ileal microcirculation. Radiation induced maximum leucocyte rolling at 2 hours and adhesion peaked at 16 hours. It also reduces the microflora count, which then starts to increase steadily afterwards. This model may be instrumental in developing strategies against pathological recruitment of leucocytes and changes in intestinal microflora in the small bowel after radiotherapy.
Collapse
|
28
|
|
29
|
|
30
|
Quantitative determinations by ion pair extraction. 10. Extraction of picrate ion pairs into polar organic solvents. ACTA PHARMACEUTICA SUECICA 1971; 8:585-90. [PMID: 5139733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
31
|
Erwiderung auf die „Bemerkungen zu der Arbeit des Herrn Dr. S. Bäck: Experimentell-histologische Untersuchungen über Contusio bulbi“ des Herrn Dr. Denig. Graefes Arch Clin Exp Ophthalmol 1899. [DOI: 10.1007/bf01940107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
|
32
|
Experimentell-histologische Untersuchungen über Contusio bulbi. Graefes Arch Clin Exp Ophthalmol 1898. [DOI: 10.1007/bf01960013] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|