1
|
Mechanical circulatory support in patients with congenital heart disease: a european registry for patients with mechanical circulatory support (EUROMACS) study. Eur J Cardiothorac Surg 2024:ezae209. [PMID: 38781499 DOI: 10.1093/ejcts/ezae209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 04/25/2024] [Accepted: 05/21/2024] [Indexed: 05/25/2024] Open
Abstract
OBJECTIVES This study aims to explore characteristics and clinical outcomes of patients with congenital heart disease (CHD) in the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). METHODS This is a retrospective study of EUROMACS participants receiving MCS as bridge-to-transplant, possible bridge-to-transplant, or rescue therapy/bridge-to-recovery from 2011 to 2023 (n = 5,340). Adult and paediatric cohorts were analysed separately. The primary outcome was mortality on MCS; secondary outcomes included recovery, transplant and complications including bleeding, cerebrovascular events, and sepsis. RESULTS Among adult patients, mortality at 1-year was 33.3% among the CHD cohort versus 22.1% in the non-CHD cohort. Adult CHD patients had higher hazards of mortality within the first year after MCS implantation (HR 1.98 95% CI 1.35-2.91, p < 0.001) and bleeding events (sdHR 2.10, 95% CI 1.40-3.16, p < 0.001) compared with non-CHD patients. Both associations remained significant after accounting for multiple mediators. Among paediatric patients, mortality at 1-year was 22.1% in the CHD cohort versus 17.3% in the non-CHD cohort (HR 1.39 95% CI 0.83-2.32, p = 0.213). CONCLUSIONS Adult and paediatric patients with CHD on MCS have higher adverse event risk compared with non-CHD MCS patients, though children did not have greater risk of mortality. As the number of CHD patients requiring advanced heart failure management continues to grow, these findings can enhance informed decision-making.
Collapse
|
2
|
Durable left ventricular assist device explantation following recovery in paediatric patients: Determinants and outcome after explantation. Eur J Cardiothorac Surg 2024; 65:ezae126. [PMID: 38613845 DOI: 10.1093/ejcts/ezae126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 01/31/2024] [Accepted: 04/11/2024] [Indexed: 04/15/2024] Open
Abstract
OBJECTIVES Myocardial recovery in children supported by a durable left ventricular assist device is a rare, but highly desirable outcome because it could potentially eliminate the need for a cardiac transplant and the lifelong need for immunosuppressant therapy and the risk of complications. However, experience with this specific outcome is extremely limited. METHODS All patients < 19 years old supported by a durable left ventricular assist device from the European Registry for Patients with Mechanical Circulatory Support database were included. Participating centres were approached for additional follow-up data after explantation. Associated factors for explantation due to myocardial recovery were explored using Cox proportional hazard models. RESULTS The incidence of recovery in children supported by a durable left ventricular assist device was 11.7% (52/445; median duration of support, 122.0 days). Multivariable analyses showed body surface area (hazard ratio 0.229; confidence interval 0.093-0.565; P = 0.001) and a primary diagnosis of myocarditis (hazard ratio 4.597; confidence interval 2.545-8.303; P < 0.001) to be associated with recovery. Left ventricular end-diastolic diameter in children with myocarditis was not associated with recovery. Follow-up after recovery was obtained for 46 patients (88.5%). Sustained myocardial recovery was reported in 33/46 (71.7%) at the end of the follow-up period (28/33; >2 year). Transplants were performed in 6/46 (11.4%) (in 5 after a ventricular assist device was reimplanted). Death occurred in 7/46 (15.2%). CONCLUSIONS Myocardial recovery occurs in a substantial portion of paediatric patients supported with durable left ventricular assist devices, and sustainable recovery is seen in around three-quarters of them. Even children with severely dilated ventricles due to myocarditis can show recovery. Clinicians should be attentive to (developing) myocardial recovery. These results can be used to develop internationally approved paediatric weaning guidelines.
Collapse
|
3
|
Use of Intracorporeal Durable LVAD Support in Children Using HVAD or HeartMate 3-A EUROMACS Analysis. J Cardiovasc Dev Dis 2023; 10:351. [PMID: 37623364 PMCID: PMC10455245 DOI: 10.3390/jcdd10080351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 07/24/2023] [Accepted: 08/01/2023] [Indexed: 08/26/2023] Open
Abstract
Purpose: The withdrawal of HVAD in 2021 created a concern for the pediatric population. The alternative implantable centrifugal blood pump HeartMate 3 has since been used more frequently in children. This paper analyses the outcome of children on LVAD support provided with an HVAD or HM3. Methods: A retrospective analysis of the EUROMACS database on children supported with VAD < 19 years of age from 1 January 2009 to 1 December 2021 was conducted. All patients with an LVAD and either an HVAD or HM3 were included. Patients with missing data on VAD status and/or missing baseline and/or follow up information were excluded. Kaplan-Meier survival analysis was performed to evaluate survival differences. Analyses were performed using Fisher's exact test. Results: The study included 150 implantations in 142 patients with 128 implants using an HVAD compared to 28 implants using an HM3. Nine patients (6%) needed temporary right ventricular mechanical support, which was significantly higher in the HM3 group, with 25% (p: 0.01). Patients in the HVAD group were significantly younger (12.7 vs. 14.5 years, p: 0.01), weighed less (45.7 vs. 60 kg, p: <0.000) and had lower BSA values (1.3 vs. 1.6 m2, p: <0.000). Median support time was 204 days. Overall, 98 patients (69%) were discharged and sent home, while 87% were discharged in group HM3 (p: ns). A total of 123 children (86%) survived to transplantation, recovery or are ongoing, without differences between groups. In the HVAD group, 10 patients (8%) died while on support, whereas in 12% of HM3 patients died (p: 0.7). Conclusions: Survival in children implanted with an HM3 was excellent. Almost 90% were discharged and sent home on the device.
Collapse
|
4
|
Myocardial recovery in children supported with a durable ventricular assist device-a systematic review. Eur J Cardiothorac Surg 2023; 64:ezad263. [PMID: 37498565 PMCID: PMC10560320 DOI: 10.1093/ejcts/ezad263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 06/18/2023] [Accepted: 07/26/2023] [Indexed: 07/28/2023] Open
Abstract
OBJECTIVES A small percentage of paediatric patients supported with a ventricular assist device (VAD) can have their device explanted following myocardial recovery. The goal of this systematic review is to summarize the current literature on the clinical course in these children after weaning. METHODS A systematic literature search was performed on 27 May 2022 using Embase, Medline ALL, Web of Science Core Collection, Cochrane Central Register of Controlled Trials and Google Scholar to include all literature on paediatric patients supported by a durable VAD during the last decade. Overlapping study cohorts and registry-based studies were filtered out. RESULTS Thirty-seven articles were included. Eighteen of them reported on the incidence of recovery in cohort studies, with an overall incidence rate of 8.7% (81/928). Twenty-two of the included articles reported on clinical outcomes after VAD explantation (83 patients). The aetiologies varied widely and were not limited to diseases with a natural transient course like myocarditis. Most of the patients in the included studies (70; 84.3%) were supported by a Berlin Heart EXCOR, and in 66.3% (55/83), only the left ventricle had to be supported. The longest follow-up period was 19.1 years, and multiple studies reported on long-term myocardial recovery. Fewer than half of the reported deaths had a cardiac cause. CONCLUSIONS Myocardial recovery during VAD support is dependent on various contributing components. The interactions among patient-, device-, time- and hospital-related factors are complex and not yet fully understood. Long-term recovery after VAD support is achievable, even after a long duration of VAD support, and even in patients with aetiologies different from myocarditis or post-cardiotomy heart failure. More research is needed on this favourable outcome after VAD support.
Collapse
|
5
|
Use of implantable cardioverter-defibrillator in children supported with ventricular assist device: An analysis of data from the EUROMACS registry. Artif Organs 2023; 47:1319-1325. [PMID: 36855905 DOI: 10.1111/aor.14515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 02/14/2023] [Accepted: 02/24/2023] [Indexed: 03/02/2023]
Abstract
BACKGROUND Data on the use and outcome of children on ventricular assist device (VAD) support provided with an implantable cardioverter-defibrillator (ICD) remains poor. METHODS A retrospective analysis of the EUROMACS database on children supported with VAD < 19 years of age from January 1, 2009 to April 1, 2020. Patients with missing data on status of ICD, missing baseline and/or follow up information were excluded. The primary independent variable of interest was the concomitant presence or absence of an ICD at the time of VAD placement. Kaplan-Meier survival analysis was performed to evaluate survival differences between children on VAD with and without an ICD. RESULTS Out of 303 patients provided with a VAD, 7% (7♀, 15♂) had an ICD implanted and formed the study group. Median age was 14 years, median weight was 43.5 kg, and median BSA was 1.39. Median Intermacs stage was 2 (range: 1-7). Seventeen patients (77%) were transplanted, 4 (18%) died while on support, and 1 (5%) was weaned from device after myocardial recovery. Median time on support was 68 days compared to 361 days in the control group (p: 0.01). Three patients underwent device exchange due to thrombus formation in the pump. There was no difference in survival between groups (p = 0.342). CONCLUSION The presence of ICD in pediatric patients supported with a VAD is low (7%). Children on VAD support provided with an ICD do not have a survival benefit compared to children without an ICD.
Collapse
|
6
|
Efficacy of levosimendan infusion in patients undergoing a left ventricular assist device implant in a propensity score matched analysis of the EUROMACS registry-the Euro LEVO-LVAD study. Eur J Cardiothorac Surg 2023; 63:ezad095. [PMID: 36912728 PMCID: PMC10693438 DOI: 10.1093/ejcts/ezad095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 03/06/2023] [Accepted: 03/10/2023] [Indexed: 03/14/2023] Open
Abstract
OBJECTIVES Early right-sided heart failure (RHF) was seen in 22% of recipients of a left ventricular assist device (LVAD) in the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). However, the optimal treatment of post-LVAD RHF is not well known. Levosimendan has proven to be effective in patients with cardiogenic shock and in those with end-stage heart failure. We sought to evaluate the efficacy of levosimendan on post-LVAD RHF and 30-day and 1-year mortality. METHODS The EUROMACS Registry was used to identify adults with mainstream continuous-flow LVAD implants who were treated with preoperative levosimendan compared to a propensity matched control cohort. RESULTS In total, 3661 patients received mainstream LVAD, of which 399 (11%) were treated with levosimendan pre-LVAD. Patients given levosimendan had a higher EUROMACS RHF score [4 (2- 5.5) vs 2 (2- 4); P < 0.001], received more right ventricular assist devices (RVAD) [32 (8%) vs 178 (5.5%); P = 0.038] and stayed longer in the intensive care unit post-LVAD implant [19 (8-35) vs 11(5-25); P < 0.001]. Yet, there was no significant difference in the rate of RHF, 30-day, or 1-year mortality. Also, in the matched cohort (357 patients taking levosimendan compared to an average of 622 controls across 20 imputations), we found no evidence for a difference in postoperative severe RHF, RVAD implant rate, length of stay in the intensive care unit or 30-day and 1-year mortality. CONCLUSIONS In this analysis of the EUROMACS registry, we found no evidence for an association between levosimendan and early RHF or death, albeit patients taking levosimendan had much higher risk profiles. For a definitive conclusion, a multicentre, randomized study is warranted.
Collapse
|
7
|
Impact of preoperative mitral regurgitation on left ventricular assist device patients: propensity score-matched analysis of the EUROMACS dataset. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY : OFFICIAL JOURNAL OF THE EUROPEAN ASSOCIATION FOR CARDIO-THORACIC SURGERY 2023; 63:6986977. [PMID: 36637204 DOI: 10.1093/ejcts/ezad013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2022] [Revised: 11/02/2022] [Accepted: 01/11/2023] [Indexed: 01/14/2023]
Abstract
OBJECTIVES Mitral regurgitation (MR) is frequently observed in patients undergoing left ventricular assist device implantation. We investigated the impact of preoperative MR on left ventricular assist device patients. METHODS A retrospective propensity score-matched analysis of adult patients enrolled in the EUROMACS registry between 1 January 2011 and 30 November 2021 was performed. Patients were divided into 2 groups according to the grade of preoperative MR: none-to-mild (MR 0-II) or moderate-to-severe (MR III-IV). RESULTS Following 1:1 propensity score matching, each group consisted of 914 patients. Incidence of postoperative temporary right ventricular support, reoperation for bleeding and dialysis was similar. MR III-IV demonstrated shorter median intensive care unit stay [14 days (6; 27.8) vs 10 days (5; 22), P = 0.004] and ventilation time [72 h (22, 320) vs 31 h (18, 150), P < 0.001]. Mortality was lower for MR III-IV patients [subdistribution hazard ratio: 0.66, 95% confidence interval (CI): 0.59-0.73, P < 0.001]. The 1-year survival was 68.1% (95% CI: 65.1-71.3%) in MR 0-II and 75% (95% CI: 72.1-78%) in MR III-IV. A lower incidence of total complications [odds ratio (OR): 0.93 (0.89-0.98), P = 0.003] and trend towards a lower risk of neurological dysfunction (subdistribution hazard ratio: 0.79; 95% CI: 0.61-1.01, P = 0.063) and sustained ventricular tachycardia [OR: 0.93 (0.54-1.03), P = 0.074] were demonstrated for MR III-IV. The risk of fatal stroke and pump thrombosis was similar. CONCLUSIONS Moderate-to-severe MR in patients undergoing left ventricular assist device implantation is associated with better mid-term survival and lower incidence of total major adverse events and complications. The incidence of severe postoperative complications including fatal stroke and device thrombosis was similar.
Collapse
|
8
|
Outcomes in small children on Berlin Heart EXCOR support: age and body surface area as clinical predictive factors. Eur J Cardiothorac Surg 2022; 63:6809124. [PMID: 36346169 PMCID: PMC9825200 DOI: 10.1093/ejcts/ezac516] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 09/25/2022] [Accepted: 11/07/2022] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVES The Berlin Heart EXCOR (BHE) offers circulatory support across all paediatric ages. Clinically, the necessary care and the outcomes differ in various age groups. The EUROMACS database was used to study age- and size-related outcomes for this specific device. METHODS All patients <19 years of age from the EUROMACS database supported with a BHE between 2000 and November 2021 were included. Maximally selected rank statistics were used to determine body surface area (BSA) cut-off values. Multivariable Cox proportional hazard regression using ridge penalization was performed to identify factors associated with outcomes. RESULTS In total, 303 patients were included [mean age: 2.0 years (interquartile range: 0.6-8.0, males: 48.5%)]. Age and BSA were not significantly associated with mortality (n = 74, P = 0.684, P = 0.679). Factors associated with a transplant (n = 175) were age (hazard ratio 1.07, P = 0.006) and aetiology other than congenital heart disease (hazard ratio 1.46, P = 0.020). Recovery rates (n = 42) were highest in patients with a BSA of <0.53 m2 (21.8% vs 4.3-7.6% at 1 year, P = 0.00534). Patients with a BSA of ≥0.73 m2 had a lower risk of early pump thrombosis but a higher risk of early bleeding compared to children with a BSA of <0.73 m2. CONCLUSIONS Mortality rates in Berlin Heart-supported patients cannot be predicted by age or BSA. Recovery rates are remarkably high in the smallest patient category (BSA <0.53 m2). This underscores that the BHE is a viable therapeutic option, even for the smallest and youngest patients.
Collapse
|
9
|
Left ventricular assist device related infections and the risk of cerebrovascular accidents: a EUROMACS study. Eur J Cardiothorac Surg 2022; 62:6673908. [PMID: 35997578 PMCID: PMC9536286 DOI: 10.1093/ejcts/ezac421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 07/28/2022] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES In patients supported by a durable left ventricular assist device (LVAD), infections are a frequently reported adverse event with increased morbidity and mortality. The purpose of this study was to investigate the possible association between infections and thromboembolic events, most notable cerebrovascular accidents (CVAs), in LVAD patients. METHODS An analysis of the multicentre European Registry for Patients Assisted with Mechanical Circulatory Support was performed. Infections were categorized as VAD-specific infections, VAD-related infections and non-VAD-related infections. An extended Kaplan–Meier analysis for the risk of CVA with infection as a time-dependent covariate and a multivariable Cox proportional hazard model were performed. RESULTS For this analysis, 3282 patients with an LVAD were included with the majority of patients being male (83.1%). During follow-up, 1262 patients suffered from infection, and 457 patients had a CVA. Cox regression analysis with first infection as time-dependent covariate revealed a hazard ratio (HR) for CVA of 1.90 [95% confidence interval (CI): 1.55–2.33; P < 0.001]. Multivariable analysis confirmed the association for infection and CVAs with an HR of 1.99 (95% CI: 1.62–2.45; P < 0.001). With infections subcategorized, VAD-specific HR was 1.56 (95% CI: 1.18–2.08; P 0.002) and VAD-related infections [HR: 1.99 (95% CI: 1.41–2.82; P < 0.001)] remained associated with CVAs, while non-VAD-related infections (P = 0.102) were not. CONCLUSIONS Infection during LVAD support is associated with an increased risk of developing an ischaemic or haemorrhagic CVA, particularly in the setting of VAD-related or VAD-specific infections. This suggests the need of a stringent anticoagulation management and adequate antibiotic treatment during an infection in LVAD-supported patients.
Collapse
|
10
|
Third-generation continuous-flow left ventricular assist devices: a comparative outcome analysis by device type. ESC Heart Fail 2022; 9:3469-3482. [PMID: 35880515 DOI: 10.1002/ehf2.13794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 10/17/2021] [Accepted: 12/16/2021] [Indexed: 11/08/2022] Open
Abstract
AIMS Continuous-flow left ventricular assist devices (CF-LVADs) have become a standard of care in end-stage heart failure. Limited data exist comparing outcomes of HeartMate3 (HM3) and HeartWare HVAD (HW). We aimed to compare midterm outcomes of these devices. METHODS AND RESULTS Investigator-initiated retrospective-observational comparative analysis of all patients who underwent primary LVAD implantation of either HM3 or HW at our centre between January 2010 and December 2020. Data were derived from a prospective registry. Primary endpoints were all-cause mortality and heart transplantation. Secondary endpoints included device-related major adverse cardiac and cerebrovascular events, which included major bleeding, major neurological dysfunction (defined as persisting neurological impairment for ≥24 h), device-related major infection (excluding driveline infections), major device malfunctions leading to re-intervention or partial device exchange (pump failure, outflow-graft twist or failure, controller failure, battery failure, patient cable failure, but excluding pump thrombosis), and pump thrombosis. Further secondary endpoints included right heart failure, gastrointestinal bleeding, driveline infections, and surgical re-interventions. The secondary outcomes were analysed not only for the first event but also for recurrent events. The analysis included competing risks analysis and recurrent event regression analysis, with adjustment for confounders age, gender, body mass index (BMI), and Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) level. Out of 106 primary CF-LVAD implantations, 36 (34%) received HM3 and 70 (66%) received HW. Median follow-up was 1.48 years [interquartile range 0.67, 2.41]. HM3 was more often implanted in men (91.7% vs. 72.9%, P = 0.024); patients were older (median 61 years [54, 66.5] vs. 52.5 years [43, 60], P < 0.001), had a higher BMI (median 26.7 kg/m2 [23.4, 29.0] vs. 24.3 kg/m2 [20.7, 27.4], P = 0.013), had more comorbidities, and were more likely targeted for destination therapy (36.1% vs. 14.3%, P = 0.010). Death occurred in 33.3% of HM3 patients, compared with 22.9% of HW patients, P = 0.247 (probability of survival at 4 years, 54.7% vs. 74.1%, P = 0.296). After adjustment for confounders, we observed a significant six-fold risk increase in device malfunctions for HW [hazard ratio (HR) 6.49, 95% confidence interval (CI) [1.89, 22.32], P = 0.003], but no significant differences in pump thrombosis (P = 0.173) or overall survival (P = 0.801). CONCLUSIONS Comparing midterm outcomes between HM3 and HW for LVAD support from a prospective registry, HW patients had a significantly higher risk of device malfunctions. No significant differences were evident between devices in overall survival and in respect to most outcomes.
Collapse
|
11
|
Cerebrovascular accidents in paediatric patients supported by the Berlin Heart EXCOR. Eur J Cardiothorac Surg 2022; 62:6645748. [PMID: 35849328 PMCID: PMC9789740 DOI: 10.1093/ejcts/ezac381] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Revised: 05/16/2022] [Accepted: 07/13/2022] [Indexed: 01/01/2023] Open
Abstract
OBJECTIVES Ventricular assist device support as a bridge to transplant or recovery is a well-established therapy in children on the cardiac transplant waiting list. The goal of this study was to investigate the incidence of and the associated factors for cerebrovascular accidents in paediatric patients supported by a Berlin Heart EXCOR. METHODS All patients <19 years of age supported by a Berlin Heart EXCOR between January 2011 and January 2021 from the European Registry for Patients with Mechanical Circulatory Support were included. RESULTS In total, 230 patients were included. A total of 140 (60.9%) patients had a diagnosis of dilated cardiomyopathy. 46 patients (20.0%) sustained 55 cerebrovascular accidents, with 70.9% of the episodes within 90 days after the ventricular assist device was implanted. The event rate of cerebrovascular accidents was highest in the first era (0.75). Pump thrombosis and secondary need for a right ventricular assist device were found to be associated with a cerebrovascular accident (hazard ratio 1.998, P = 0.040; hazard ratio 11.300, P = 0.037). At the 1-year follow-up, 44.4% of the patients had received a transplant, 13.1% were weaned after recovery and 24.5% had died. Event rates for mortality showed a significantly decreasing trend. CONCLUSIONS Paediatric ventricular assist device support is associated with important adverse events, especially in the early phase after the device is implanted. Pump thrombosis and the need for a secondary right ventricular assist device are associated with cerebrovascular accidents. Furthermore, an encouragingly high rate of recovery in this patient population was shown, and death rates declined. More complete input of data into the registry, especially concerning anticoagulation protocols, would improve the data.
Collapse
|
12
|
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): third Paediatric (Paedi-EUROMACS) report. Eur J Cardiothorac Surg 2022; 62:6618527. [PMID: 35758622 DOI: 10.1093/ejcts/ezac355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 05/23/2022] [Accepted: 06/25/2022] [Indexed: 11/14/2022] Open
|
13
|
Impact of concomitant cardiac valvular surgery during implantation of continuous-flow left ventricular assist devices: A European registry for patients with mechanical circulatory support (EUROMACS) analysis. Artif Organs 2021; 46:813-826. [PMID: 34904255 DOI: 10.1111/aor.14143] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2021] [Revised: 07/22/2021] [Accepted: 12/08/2021] [Indexed: 01/13/2023]
Abstract
BACKGROUND We investigated the clinical outcomes after cardiac valvular surgery procedures concomitant (CCPs) with left ventricular assist device (LVAD) implantation compared to propensity score (PS) matched controls using the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) data. METHODS Between 2006 and 2018, 2760 continuous-flow LVAD patients were identified. Of these, 533 underwent a CCP during the LVAD implant. RESULTS Cardiopulmonary bypass time (p < 0.001) and time for implant (p < 0.001) were both significantly longer in the LVAD+CCP group. Hospital mortality was comparable between the two groups from the unmatched population (15.7% vs. 14.1%, p = 0.073). Similarly, short-to-mid-term survival was similar in both groups, with 1-year, 3-year, and 5-year survival rates of 67.9%, 48.2%, and 27.7% versus 66.4%, 46.1%, and 26%, respectively (log-rank, p = 0.25). The results were similar in the PS-matched population. Hospital mortality was comparable between the two groups (18.9% vs. 17.4%, p = 0.074). The short-to-mid-term Kaplan-Meier survival analysis was similar for both groups, with 1-year, 3-year, and 5-year survival rates of 63.4%, 49.2%, and 24.7% versus 66.5%, 46%, and 25.1%, respectively (log-rank, p = 0.81). In the unmatched population, LVAD+CCP patients had longer intensive care unit (ICU) stays (p < 0.0001), longer mechanical ventilation time (p = 0.001), a higher rate of temporary right ventricular assist device (RVAD) support (p = 0.033), and a higher rate of renal replacement therapy (n = 35, 6.6% vs. n = 89, 4.0%, p = 0.014). In the PS-matched population, the LVAD+CCP patients had longer ICU stays (p = 0.019) and longer mechanical ventilation time (p = 0.002). CONCLUSIONS The effect of additive valvular procedures (CCPs) does not seem to affect short-term survival, significantly, based on our registry data analysis. However, the decision to perform CCPs should be balanced with the projected type of surgery and preoperative characteristics. LVAD+CCP patients remain a delicate population and adverse device-related events should be strictly monitored and managed.
Collapse
|
14
|
Gender differences in psychosocial and clinical characteristics in the European Registry for Patients with Mechanical Circulatory Support. Heart Lung 2021; 50:845-852. [PMID: 34325182 DOI: 10.1016/j.hrtlng.2021.06.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 06/11/2021] [Accepted: 06/24/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND Not much is known about psychosocial characteristics of men and women receiving continuous flow left ventricular assist devices (CF LVAD). OBJECTIVE To investigate gender differences in clinical and psychosocial (demographic, behavioral, psychological) characteristics in CF LVAD recipients. METHODS We analyzed European Registry for Patients with Mechanical Circulatory Support (EUROMACS) data (N=2395, 16.8% women; 2011 to 2017) and compared pre-implant characteristics in men and women intended for bridge-to-transplant (BTT) or destination therapy (DT). RESULTS Women were underrepresented [DT (n=61): 13.4%; BTT (n=341): 17.6%]. They were more likely to be divorced/separated, widowed, in unstable clinical condition, and non-working (DT only), but less likely to be smokers, to have ischemic cardiomyopathy or diabetes, and younger (BTT only) than men. Missing data were abundant, especially those that reflect psychological characteristics (>87%). CONCLUSION Gender differences were noted, some specific to device strategy. Improved collection of psychosocial characteristics is warranted to elucidate their relationship to future prognosis.
Collapse
|
15
|
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): second EUROMACS Paediatric (Paedi-EUROMACS) report. Eur J Cardiothorac Surg 2021; 57:1038-1050. [PMID: 32364221 DOI: 10.1093/ejcts/ezaa132] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Revised: 02/27/2020] [Accepted: 03/03/2020] [Indexed: 11/14/2022] Open
Abstract
OBJECTIVES A second paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. METHODS Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (≤19 years of age) performed from 1 January 2000 to 1 July 2019 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. RESULTS Twenty-nine hospitals contributed 398 registered implants in 353 patients (150 female, 203 male) to the registry. The most frequent aetiology of heart failure was any form of cardiomyopathy (61%), followed by congenital heart disease and myocarditis (16.4% and 16.1%, respectively). Competing outcomes analysis revealed that a total of 80% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 20% died while on support. At 12 months, 46.7% received transplants, 8.7% were weaned from their device and 18.5% died. The 3-month adverse events rate was 1.69 per patient-year for device malfunction including pump exchange, 0.48 for major bleeding, 0.64 for major infection and 0.78 for neurological events. CONCLUSIONS The overall survival rate was 81.5% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age) (P = 0.01) and lower weight (<20 kg) (P = 0.015). Transplant rates at 6 months continue to be low (33.2%) The fact that the EUROMACS registry is embedded within the European Association for Cardio-Thoracic Surgery Quality Improvement Programme offers opportunities to focus on improving outcomes.
Collapse
|
16
|
Clinical impact and 'natural' course of uncorrected tricuspid regurgitation after implantation of a left ventricular assist device: an analysis of the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). Eur J Cardiothorac Surg 2021; 59:207-216. [PMID: 33038216 PMCID: PMC7781523 DOI: 10.1093/ejcts/ezaa294] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Revised: 06/15/2020] [Accepted: 06/27/2020] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVES ![]()
Data on the impact and course of uncorrected tricuspid regurgitation (TR) during left ventricular assist device (LVAD) implantation are scarce and inconsistent. This study explores the clinical impact and natural course of uncorrected TR in patients after LVAD implantation.
METHODS The European Registry for Patients with Mechanical Circulatory Support was used to identify adult patients with LVAD implants without concomitant tricuspid valve surgery. A mediation model was developed to assess the association of TR with 30-day mortality via other risk factors. Generalized mixed models were used to model the course of post-LVAD TR. Joint models were used to perform sensitivity analyses. RESULTS A total of 2496 procedures were included (median age: 56 years; men: 83%). TR was not directly associated with higher 30-day mortality, but mediation analyses suggested an indirect association via preoperative elevated right atrial pressure and creatinine (P = 0.035) and bilirubin (P = 0.027) levels. Post-LVAD TR was also associated with increased late mortality [hazard ratio 1.16 (1.06–1.3); P = 0.001]. On average, uncorrected TR diminished after LVAD implantation. The probability of having moderate-to-severe TR immediately after an implant in patients with none-to-mild TR pre-LVAD was 10%; in patients with moderate-to-severe TR pre-LVAD, it was 35% and continued to decrease in patients with moderate-to-severe TR pre-LVAD, regardless of pre-LVAD right ventricular failure or pulmonary hypertension. CONCLUSIONS Uncorrected TR pre-LVAD and post-LVAD is associated with increased early and late mortality. Nevertheless, on average, TR diminishes progressively without intervention after an LVAD implant. Therefore, these data suggest that patient selection for concomitant tricuspid valve surgery should not be based solely on TR grade.
Collapse
|
17
|
The outcome of patients with peripartum cardiomyopathy and consecutive implantation of a left ventricular assist device. J Card Surg 2021; 36:2651-2657. [PMID: 33960521 DOI: 10.1111/jocs.15598] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Revised: 03/03/2021] [Accepted: 04/18/2021] [Indexed: 11/27/2022]
Abstract
OBJECTIVES Peripartum cardiomyopathy (PPCM) is a form of systolic heart failure occurring toward the end of pregnancy or in the period after delivery. Lack of myocardial recovery or therapy-refractory cardiogenic shock are rare complications and left ventricular assist device (LVAD) systems might be used as a life-saving option. The aim of this study was to investigate outcomes of PPCM patients supported with LVAD, registered in the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). METHODS All patients registered in EUROMACS with a primary diagnosis of PPCM were included in this study. Demographic, preoperative, intraoperative, postoperative, and follow-up data were collected and patients analysed concerning their outcome after initiation of LVAD therapy. RESULTS Between May 2011 and September 2018, 16 patients with PPCM and consecutive LVAD implantation were enrolled into EUROMACS. The median age of the patient population was 31 (26;41) years with a mean left ventricular ejection fraction (LV-EF) of 15% ± 6%. In-hospital mortality after LVAD implantation was 6% (n = 1). One-year mortality accounted for 13% (n = 2). Six patients (40%) were transplanted with a median support time of 769 (193;1529) days. Weaning of LVAD support due to ventricular recovery was feasible in 3 (20%) patients. CONCLUSION In patients with severe PPCM, LVAD therapy is associated with considerably low in-hospital mortality, potentially allowing bridging to heart transplantation, or left ventricular recovery. Therefore, durable mechanical support should be considered as a treatment option in this, by nature, young and often otherwise healthy patient population.
Collapse
|
18
|
Propensity score-based analysis of long-term follow-up in patients supported with durable centrifugal left ventricular assist devices: the EUROMACS analysis. Eur J Cardiothorac Surg 2021; 60:579-587. [PMID: 33871594 DOI: 10.1093/ejcts/ezab144] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 02/08/2021] [Accepted: 02/22/2021] [Indexed: 11/14/2022] Open
Abstract
OBJECTIVES The HeartWare HVAD (HW) and the HeartMate3 (HM3) are presently the most commonly used continuous-flow left ventricular assist devices worldwide. We compared the outcomes of patients supported with either of these 2 devices based on data from the EUROMACS (European Registry for Patients with Mechanical Circulatory Support). METHODS A retrospective analysis of the survival and complications profile in propensity score-matched adult patients enrolled in the EUROMACS between 01 January 2016 and 01 September 2020 and supported with either an HW or HM3. Matching included demographic parameters, severity of cardiogenic shock and risk-modifying end-organ parameters that impact long-term survival. Survival on device and major postoperative adverse events were analysed. RESULTS Following 1:1 propensity score matching, each group consisted of 361 patients. Patients were well balanced (<0.1 standardized mean difference). The median follow-up was similar in both groups [396 (interquartile range (IQR) 112-771) days for HW and 376 (IQR 100-816) days for HM3]. The 2-year survival was similar in both groups [HW: 61% 95% confidence interval (CI) (56-67%) vs HM3: 68% 95% CI (63-73%) (stratified hazard ratio for mortality: 1.13 95% CI (0.83-1.54), P = 0.435].The cumulative incidence for combined major adverse events and unexpected readmissions was similar in both groups [subdistribution hazard ratio (SHR) 1.0 (0.84-1.21), P = 0.96]. Patients in the HW group demonstrated a higher risk of device malfunction [SHR 2.44 (1.45-3.71), P < 0.001], neurological dysfunction [SHR 1.29 (1.02-1.61), P = 0.032] and intracranial bleeding [SHR 1.76 (1.13-2.70), P = 0.012]. CONCLUSIONS Mid-term survival in both groups was similar in a propensity-matched analysis. The risk of device malfunction, neurological dysfunction and intracranial bleeding was significantly higher in HW patients.
Collapse
|
19
|
Results of primary biventricular support: an analysis of data from the EUROMACS registry. Eur J Cardiothorac Surg 2020; 56:1037-1045. [PMID: 31369075 DOI: 10.1093/ejcts/ezz173] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2018] [Revised: 05/01/2019] [Accepted: 05/05/2019] [Indexed: 11/14/2022] Open
Abstract
OBJECTIVES The purpose of this study was to describe pre- and postoperative data from the EUROMACS registry with regard to indications, for and survival and complication rates of patients with primary continuous flow and pulsatile biventricular long-term assist devices (BiVADs) versus total artificial hearts (TAHs) or left ventricular assist devices (LVADs) + short-term right ventricular assist device (RVAD) implants. METHODS We investigated patients who received implants between 1 January 2011 and 21 October 2017. Clinical baseline information about comorbidities, laboratory results, medical and device therapies and echocardiographic, haemodynamic and right ventricle (RV) parameters were evaluated along with the rates of deaths and complications. RESULTS A total of 413 of 3282 patients (12.5%) needed a biventricular pump. We investigated 37 long-term BiVADs, 342 LVAD + short-term RVAD implants and 34 TAHs. Minor differences were found in the baseline characteristics of our population, which had an overall high morbidity profile. The 1-year survival rate was 55% for patients with a continuous flow BiVAD; 52% for patients with an LVAD + short-term RVAD; 37% for patients with pulsatile BiVADs; and 36% for patients with a TAH. No statistical difference was observed among the groups. Over 50% of patients with BiVAD support were classified as INTERMACS profiles 1 and 2. The percent of patients with ambulatory heart failure (INTERMACS 4‒7) undergoing BiVAD implants was modest at <15%. No patients with a pulsatile BiVAD (n = 15) or a TAH (n = 34) were implanted as destination therapy, but 27% of the patients with continuous flow BiVADs (n = 6) and 23% of the patients with LVAD + short-term RVAD (n = 342) were implanted as 'destination'. The adverse events profile remained high, with no significant difference among pump types. The right ventricular stroke work index and right heart failure scores indicated poor RV function in all groups. After 3 months of LVAD + short-term RVAD support, 46.7% still required ongoing support, and only 18.5% were weaned from RVAD support; 33.1% died. CONCLUSIONS The mortality rate after BiVAD support was high. Survival rates and adverse events were statistically not different among the investigated groups. In the future, composite study end points examining quality of life and adverse events beyond survival may help in shared decision-making prior to general mechanical circulatory support, particularly in patients with BiVAD implants.
Collapse
|
20
|
Corrigendum to: The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): first EUROMACS Paediatric (Paedi-EUROMACS) report [Eur J Cardiothorac Surg 2018;54:800-8]. Eur J Cardiothorac Surg 2020; 57:1019-1020. [PMID: 32324241 DOI: 10.1093/ejcts/ezaa092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
21
|
Outcomes of patients after successful left ventricular assist device explantation: a EUROMACS study. ESC Heart Fail 2020; 7:1085-1094. [PMID: 32196996 PMCID: PMC7261531 DOI: 10.1002/ehf2.12629] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Revised: 01/03/2020] [Accepted: 01/09/2020] [Indexed: 11/11/2022] Open
Abstract
AIMS Sufficient myocardial recovery with the subsequent explantation of a left ventricular assist device (LVAD) occurs in approximately 1-2% of the cases. However, follow-up data about this condition are scarcely available in the literature. This study aimed to report the long-term outcomes and clinical management following LVAD explantation. METHODS AND RESULTS An analysis of the European Registry for Patients with Mechanical Circulatory Support was performed to identify all adult patients with myocardial recovery and successful explantation. Pre-implant characteristics were retrieved and compared with the non-recovery patients. The follow-up data after explantation were collected via a questionnaire. A Kaplan-Meier analysis for freedom of the composite endpoint of death, heart transplantation, LVAD reimplantion, or heart failure (HF) relapse was conducted. A total of 45 (1.4%) cases with myocardial recovery resulting in successful LVAD explantation were identified. Compared with those who did not experience myocardial recovery, the explanted patients were younger (44 vs. 56 years, P < 0.001), had a shorter duration of cardiac disease (P < 0.001), and were less likely to have ischaemic cardiomyopathy (9% vs. 41.8%, P < 0.001). Follow-up after explantation could be acquired in 28 (62%) cases. The median age at LVAD implantation was 43 years (inter-quartile range: 29-52), and 23 (82%) were male. Baseline left ventricular ejection fraction was 18% (inter-quartile range: 10-20%), and 60.7% of the patients had Interagency Registry for Mechanically Assisted Circulatory Support Profile 1 or 2. Aetiologies of HF were dilated cardiomyopathy in 36%, myocarditis in 32%, and ischaemic in 14% of the patients, and 18% had miscellaneous aetiologies. The devices implanted were HeartMate II in 14 (50%), HVAD in 11 (39%), HeartMate 3 in 2 (7%), and 1 unknown with a median duration of support of 410 days (range: 59-1286). The median follow-up after explantation was 26 months (range 0.3-73 months), and 82% of the patients were in New York Heart Association Class I or II. Beta-blockers were prescribed to 85%, angiotensin-converting enzyme inhibitors to 71%, and loop diuretics to 50% of the patients, respectively. Freedom from the composite endpoint was 100% after 30 days and 88% after 2 years. CONCLUSIONS The survival after LVAD explantation is excellent without the need for heart transplantation or LVAD reimplantation. Only a minority of the patients suffer from a relapse of significant HF.
Collapse
|
22
|
Causes and predictors of early mortality in patients treated with left ventricular assist device implantation in the European Registry of Mechanical Circulatory Support (EUROMACS). Intensive Care Med 2020; 46:1349-1360. [PMID: 32016536 PMCID: PMC7334284 DOI: 10.1007/s00134-020-05939-1] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Accepted: 01/13/2020] [Indexed: 12/21/2022]
Abstract
PURPOSE The aim of the study was to analyze early mortality after continuous-flow left ventricular assist device (LVAD) implantation which remains high. METHODS We analyzed consecutive (n = 2689) patients from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) undergoing continuous-flow LVAD implantation. The primary outcome was early (< 90 days) mortality. Secondary outcomes were differential causes of early post-operative death following LVAD implantation. RESULTS Univariable and multivariable analysis as well as regression analysis were used to examine determinants and differential causes of early (< 90 days) mortality after LVAD implantation. During the first 90 days, 2160 (80%) patients were alive with ongoing LVAD support, 40(2%) patients underwent heart transplantation, and 487(18%) deceased. The main causes of early death were MOF (36%), sepsis (28%), cardiopulmonary failure (CPF; 10%), CVA (9%), and right-sided heart failure (RHF, 8%). Furthermore, MOF and sepsis are 70% of causes of death in the first week. Independent clinical predictors of early death were age, female sex, INTERMACS profile 1 to 3, and ECMO. Laboratory predictors included elevated serum creatinine, total bilirubin, lactate, and low hemoglobin. Furthermore, hemodynamic predictors included elevated RA-to-PCWP ratio, pulmonary vascular resistance, and low systemic vascular resistance. Longer total implantation time was also independent predictor of early mortality. A simple model of 12 variables predicts early mortality following LVAD implantation with a good discriminative power with area under the curve of 0.75. CONCLUSIONS In the EUROMACS registry, approximately one out of five patients die within 90 days after LVAD implantation. Early mortality is primarily dominated by multiorgan failure followed by sepsis. A simple model identifies important parameters which are associated with early mortality following LVAD implantation.
Collapse
|
23
|
Consolidated quality improvements following benchmarking with cardiothoracic surgery registries—a systematic review. Eur J Cardiothorac Surg 2019; 57:817-825. [DOI: 10.1093/ejcts/ezz330] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2019] [Revised: 11/05/2019] [Accepted: 11/06/2019] [Indexed: 12/16/2022] Open
Abstract
Abstract
The influence of registries in medicine is large. However, there has been no systematic assessment conducted to quantify the impact of benchmarking with registries focused on cardiothoracic surgery. Numerous publications conclude that registry participation leads to improvement of outcomes for patients. A large number of registries provide evidence sub-structured by statistics that show decreases in morbidity and mortality in the participants’ clinical units. Many authors praise the benchmarking method making use of databases of registries as having a positive effect on outcome of care. However, studies proving the direct causal relation between the use of cardiothoracic surgery-oriented registries and improvement of clinical in-hospital outcomes are extremely scarce. We aimed to analyse the causal relation between the use of cardiothoracic surgery-oriented registries and improvement of clinical outcomes. In a systematic literature review, publications demonstrating the use of registry data to obtain consolidated quality improvements were selected. After analysis of 2990 scientific publications, 6 studies filled the inclusion criteria. The selected studies acknowledged that benchmarking of data against registries was used for a focused and methodologically organized improvement in cardiothoracic departments. In conjunction with the impact of the applied methods on healthcare, their results demonstrate quantifiable enhanced local outcomes over time.
Collapse
|
24
|
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) of the European Association for Cardio-Thoracic Surgery (EACTS): second report. Eur J Cardiothorac Surg 2019; 53:309-316. [PMID: 29029117 DOI: 10.1093/ejcts/ezx320] [Citation(s) in RCA: 97] [Impact Index Per Article: 19.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2017] [Revised: 08/08/2017] [Accepted: 08/13/2017] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVES The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) was founded in Berlin, Germany. EUROMACS is supported fully by the European Association for Cardio-Thoracic Surgery (EACTS) and, since 2014, has functioned as a committee of the EACTS. The purpose of having the EUROMACS as a part of the EACTS is to accumulate clinical data related to long-term mechanical circulatory support for scientific purposes and to publish annual reports. METHODS Participating hospitals contributed surgical and cardiological pre-, peri- and long-term postoperative data of mechanical circulatory support implants to the registry. Data for all implants performed from 1 January 2011 to 31 December 2016 were analysed. Several auditing methods were used to monitor the quality of the data. Data could be provided for in-depth studies, and custom data could be provided at the request of clinicians and scientists. This report includes updates of patient characteristics, implant frequency, mortality rates and adverse events. RESULTS Fifty-two hospitals participated in the registry. This report is based on 2947 registered implants in 2681 patients. Survival of adult patients (>17 years of age) with continuous-flow left ventricular assist devices with a mean follow-up of 391 days was 69% (95% confidence interval 66-71%) 1 year after implantation. On average, patients were observed for 12 months (median 7 months, range 0-70 months). When we investigated for adverse events, we found an overall event rate per 100 patient-months of 3.56 for device malfunction, 6.45 for major bleeding, 6.18 for major infection and 3.03 for neurological events within the first 3 months after implantation. CONCLUSIONS Compared to the first EUROMACS report, the number of participating hospitals increased from 21 to 52 (+148%), whereas the number of registered implants more than tripled from 825 to 2947 (+257%). The increase in the number of participating hospitals led us to increase the quality control measures through data input control, on-site audits and statistical analyses.
Collapse
|
25
|
Outcomes after tricuspid valve surgery concomitant with left ventricular assist device implantation in the EUROMACS registry: a propensity score matched analysis. Eur J Cardiothorac Surg 2019; 56:1081-1089. [DOI: 10.1093/ejcts/ezz208] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Revised: 06/03/2019] [Accepted: 06/06/2019] [Indexed: 11/14/2022] Open
Abstract
Abstract
OBJECTIVES
Tricuspid regurgitation (TR) is common in patients receiving a left ventricular assist device (LVAD). Controversy exists as to whether concomitant tricuspid valve surgery (TVS) is beneficial in currently treated patients. Therefore, our goal was to investigate the effect of TVS concomitant with a LVAD implant.
METHODS
The European Registry for Patients with Mechanical Circulatory Support was used to identify adult patients. Matched patients with and without concomitant TVS were compared using a propensity score matching strategy.
RESULTS
In total, 3323 patients underwent LVAD implantation of which 299 (9%) had TVS. After matching, 258 patients without TVS were matched to 258 patients with TVS. In the matched population, hospital deaths, days on inotropic support, temporary right ventricular assist device implants and hospital stay were comparable, whereas stay in the intensive care unit was higher in the TVS cohort (11 vs 15 days; P = 0.026). Late deaths (P = 0.17), cumulative incidence of unexpected hospital readmission (P = 0.15) and right heart failure (P = 0.55) were comparable between patients with and without concomitant TVS. In the matched population, probability of moderate-to-severe TR immediately after surgery was lower in patients with concomitant TVS compared to patients without TVS (33% vs 70%; P = 0.001). Nevertheless, the probability of moderate-to-severe TR decreased more quickly in patients without TVS (P = 0.030), resulting in comparable probabilities of moderate-to-severe TR within 1.5 years of follow-up.
CONCLUSIONS
In matched patients, TVS concomitant with LVAD implant does not seem to be associated with better clinical outcomes. Concomitant TVS reduced TR significantly early after LVAD implant; however, differences in probability of TR disappeared during the follow-up period.
Collapse
|
26
|
Validation of microbiological testing in cardiovascular tissue establishments: results of a second international quality-round trial. Eur J Clin Microbiol Infect Dis 2019; 38:1481-1490. [DOI: 10.1007/s10096-019-03576-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Accepted: 04/30/2019] [Indexed: 12/01/2022]
|
27
|
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): first EUROMACS Paediatric (Paedi-EUROMACS) report. Eur J Cardiothorac Surg 2018; 54:800-808. [DOI: 10.1093/ejcts/ezy298] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2018] [Accepted: 07/24/2018] [Indexed: 11/13/2022] Open
Abstract
Abstract
OBJECTIVES:
EUROMACS is a registry of the European Association for Cardio-Thoracic Surgery (EACTS) whose purpose is to gather clinical data related to durable mechanical circulatory support for scientific purposes and to publish annual reports. Because the treatment of children with end-stage heart failure has several significantly different characteristics than the treatment of adults, data and outcomes of interventions are analysed in this dedicated paediatric report.
METHODS:
Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (≤19 years of age) performed from 1 January 2000 to 31 December 2017 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events.
RESULTS:
Twenty-five hospitals contributed 237 registered implants in 210 patients (81 ♀, 129 ♂) to the registry. The most frequent diagnosis was any form of cardiomyopathy (71.4%) followed by congenital heart disease (18.6%). Overall mean support time on a device was 11.6 months (±16.5 standard deviation). A total of 173 children (82.4%) survived to transplant, recovery or are ongoing; 37 patients (17.6%) died while on support within the observed follow-up time. At 12 months 38% of patients received transplants, 7% were weaned from their device and 15% died. At 24 months, 51% of patients received transplants, 17% died while on support, 22% were on a device and 9% were explanted due to myocardial recovery. The adverse events rate per 100 patient-months was 11.97 for device malfunction, 2.83 for major bleeding, 2.83 for major infection and 1.52 for neurological events within the first 3 months after implantation.
CONCLUSIONS:
The first paediatric EUROMACS report reveals a low transplant rate in European countries within the first 2 years of implantation compared to US data. The 1-year survival rate seems to be satisfactory. Device malfunction including pump chamber changes due to thrombosis was the most frequent adverse event.
Collapse
|
28
|
Validation of microbiological testing in cardiovascular tissue banks: results of a quality round trial. Eur J Cardiothorac Surg 2018; 52:895-900. [PMID: 28605496 DOI: 10.1093/ejcts/ezx178] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2016] [Accepted: 03/23/2017] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES Surgeons needing human cardiovascular tissue for implantation in their patients are confronted with cardiovascular tissue banks that use different methods to identify and decontaminate micro-organisms. To elucidate these differences, we compared the quality of processing methods in 20 tissue banks and 1 reference laboratory. We did this to validate the results for accepting or rejecting tissue. We included the decontamination methods used and the influence of antibiotic cocktails and residues with results and controls. The minor details of the processes were not included. METHODS To compare the outcomes of microbiological testing and decontamination methods of heart valve allografts in cardiovascular tissue banks, an international quality round was organized. Twenty cardiovascular tissue banks participated in this quality round. The quality round method was validated first and consisted of sending purposely contaminated human heart valve tissue samples with known micro-organisms to the participants. The participants identified the micro-organisms using their local decontamination methods. RESULTS Seventeen of the 20 participants correctly identified the micro-organisms; if these samples were heart valves to be released for implantation, 3 of the 20 participants would have decided to accept their result for release. Decontamination was shown not to be effective in 13 tissue banks because of growth of the organisms after decontamination. Articles in the literature revealed that antibiotics are effective at 36°C and not, or less so, at 2-8°C. The decontamination procedure, if it is validated, will ensure that the tissue contains no known micro-organisms. CONCLUSIONS This study demonstrates that the quality round method of sending contaminated tissues and assessing the results of the microbiological cultures is an effective way of validating the processes of tissue banks. Only when harmonization, based on validated methods, has been achieved, will surgeons be able to fully rely on the methods used and have confidence in the consistent sterility of the tissue grafts. Tissue banks should validate their methods so that all stakeholders can trust the outcomes.
Collapse
|
29
|
Cerebral strokes in children on intracorporeal ventricular assist devices: analysis of the EUROMACS Registry. Eur J Cardiothorac Surg 2017; 53:416-421. [DOI: 10.1093/ejcts/ezx342] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2017] [Revised: 08/07/2017] [Accepted: 08/09/2017] [Indexed: 11/14/2022] Open
|