1
|
Cortical bone quality affectations and their strength impact analysis using holographic interferometry. BIOMEDICAL OPTICS EXPRESS 2018; 9:4818-4833. [PMID: 30319905 PMCID: PMC6179407 DOI: 10.1364/boe.9.004818] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Revised: 08/08/2018] [Accepted: 08/09/2018] [Indexed: 06/08/2023]
Abstract
It is now accepted that bone strength is a complex property determined mainly by three factors: quantity, quality and turnover of the bone itself. Most of the patients who experience fractures due to fragility could never develop affectations related to bone mass density (i.e. osteoporosis). In this work, the effect of secondary bone strength affectations are analyzed by simulating the degradation of one or more principal components (organic and inorganic) while they are inspected with a nondestructive optical technique. From the results obtained, a strong correlation among the hydroxyapatite, collagen and water is found that determines the bone strength.
Collapse
|
2
|
Wavefront division digital holographic microscopy. BIOMEDICAL OPTICS EXPRESS 2018; 9:2779-2784. [PMID: 30258690 PMCID: PMC6154202 DOI: 10.1364/boe.9.002779] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Revised: 04/17/2018] [Accepted: 04/18/2018] [Indexed: 05/29/2023]
Abstract
Digital holographic microscopy is the state of the art quantitative phase imaging of micro-objects including living cells. It is an ideal tool to image and quantify cell thickness profiles with nanometer thickness resolution. Digital holographic techniques usually are implemented using a two-beam setup that may be bulky and may not be field portable. Self-referencing techniques provide compact geometry but suffer from a reduction of the field of view. Here, we discuss the development of a wavefront division digital holographic microscope providing the full field of view with a compact system. The proposed approach uses a wavefront division module consisting of two lenses. The developed microscope is tested experimentally by measuring the physical and mechanical properties of red blood cells.
Collapse
|
3
|
Adaptive optics via self-interference digital holography for non-scanning three-dimensional imaging in biological samples. BIOMEDICAL OPTICS EXPRESS 2018; 9:2614-2626. [PMID: 30258677 PMCID: PMC6154187 DOI: 10.1364/boe.9.002614] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2018] [Revised: 04/26/2018] [Accepted: 04/27/2018] [Indexed: 05/18/2023]
Abstract
Three-dimensional imaging in biological samples usually suffers from performance degradation caused by optical inhomogeneities. Here we proposed an approach to adaptive optics in fluorescence microscopy where the aberrations are measured by self-interference holographic recording and then corrected by a post-processing optimization procedure. In our approach, only one complex-value hologram is sufficient to measure and then correct the aberrations, which results in fast acquisition speed, lower exposure time, and the ability to image in three-dimensions without the need to scan the sample or any other element in the system. We show proof-of-principle experiments on a tissue phantom containing fluorescence particles. Furthermore, we present three-dimensional reconstructions of actin-labeled MCF7 breast cancer cells, showing improved resolution after the correction of aberrations. Both experiments demonstrate the validity of our method and show the great potential of non-scanning adaptive three-dimensional microscopy in imaging biological samples with improved resolution and signal-to-noise ratio.
Collapse
|
4
|
Biodynamic digital holography of chemoresistance in a pre-clinical trial of canine B-cell lymphoma. BIOMEDICAL OPTICS EXPRESS 2018; 9:2214-2228. [PMID: 29760982 PMCID: PMC5946783 DOI: 10.1364/boe.9.002214] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2018] [Revised: 04/05/2018] [Accepted: 04/06/2018] [Indexed: 05/08/2023]
Abstract
Biodynamic digital holography was used to obtain phenotypic profiles of canine non-Hodgkin B-cell lymphoma biopsies treated with standard-of-care chemotherapy. Biodynamic signatures from the living 3D tissues were extracted using fluctuation spectroscopy from intracellular Doppler light scattering in response to the molecular mechanisms of action of therapeutic drugs that modify a range of internal cellular motions. The standard-of-care to treat B-cell lymphoma in both humans and dogs is a combination CHOP therapy that consists of doxorubicin, prednisolone, cyclophosphamide and vincristine. The proportion of dogs experiencing durable cancer remission following CHOP chemotherapy was 68%, with 13 out of 19 dogs responding favorably to therapy and 6 dogs failing to have progression-free survival times greater than 100 days. Biodynamic signatures were found that correlate with inferior survival times, and biomarker selection was optimized to identify specific Doppler signatures related to chemoresistance. A machine learning classifier was constructed based on feature vector correlations and linear separability in high-dimensional feature space. Hold-out validation predicted patient response to therapy with 84% accuracy. These results point to the potential for biodynamic profiling to contribute to personalized medicine by aiding the selection of chemotherapy for cancer patients.
Collapse
|
5
|
Integral refractive index imaging of flowing cell nuclei using quantitative phase microscopy combined with fluorescence microscopy. BIOMEDICAL OPTICS EXPRESS 2018. [PMID: 29541511 PMCID: PMC5846521 DOI: 10.1364/boe.9.001177] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
We suggest a new multimodal imaging technique for quantitatively measuring the integral (thickness-average) refractive index of the nuclei of live biological cells in suspension. For this aim, we combined quantitative phase microscopy with simultaneous 2-D fluorescence microscopy. We used 2-D fluorescence microscopy to localize the nucleus inside the quantitative phase map of the cell, as well as for measuring the nucleus radii. As verified offline by both 3-D confocal fluorescence microscopy and 2-D fluorescence microscopy while rotating the cells during flow, the nucleus of cells in suspension that are not during division can be assumed to be an ellipsoid. The entire shape of a cell in suspension can be assumed to be a sphere. Then, the cell and nucleus 3-D shapes can be evaluated based on their in-plain radii available from the 2-D phase and fluorescent measurements, respectively. Finally, the nucleus integral refractive index profile is calculated. We demonstrate the new technique on cancer cells, obtaining nucleus refractive index values that are lower than those of the cytoplasm, coinciding with recent findings. We believe that the proposed technique has the potential to be used for flow cytometry, where full 3-D refractive index tomography is too slow to be implemented during flow.
Collapse
|
6
|
Quantitative observations on cytoskeleton changes of osteocytes at different cell parts using digital holographic microscopy. BIOMEDICAL OPTICS EXPRESS 2018; 9:72-85. [PMID: 29359088 PMCID: PMC5772590 DOI: 10.1364/boe.9.000072] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2017] [Revised: 11/30/2017] [Accepted: 11/30/2017] [Indexed: 05/10/2023]
Abstract
Cytoskeletons such as F-actin have different distributions in different cell parts and they are the cause of different degrees of cell collapse when the F-actin is disrupted. It is challenging to use conventional methods such as fluorescence microscopy and atomic force microscopy to conduct real-time and three-dimensional observations on the dynamic processes at different cell parts due to the slow measuring speed and the need for live-cell staining. In this study, the morphological variations of different bone cell parts caused by F-actin disruption are dynamically measured by using digital holographic microscopy (DHM). We separately analyze local parameters (cell height and cell width) and global parameters (cell projected area and cell volume) of cells to address variations of specific cell areas and quantify the changing process of the whole cell. We found significant differences in temporal variations of both local and global cell parameters between the cell body and cell process, which is consistent with the qualitative observation by fluorescence staining. Our study not only validates the unique ability of DHM to simultaneously investigate the dynamic process at different cell parts, but also provides sufficient experimental bases for exploring the mechanism for F-actin disruption.
Collapse
|
7
|
Phase distribution analysis of tissues based on the off-axis digital holographic hybrid reconstruction algorithm. BIOMEDICAL OPTICS EXPRESS 2018; 9:1-13. [PMID: 29359083 PMCID: PMC5772566 DOI: 10.1364/boe.9.000001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Revised: 11/16/2017] [Accepted: 11/28/2017] [Indexed: 06/07/2023]
Abstract
Off-axis digital holography (DH) has great potential in histopathology for its high efficiency and precision. Phase distribution, usually extracted by the angular spectrum (AS) algorithm from a digital hologram, reflects important structural information of biological tissues. However, the complex structure of tissues introduces spectrum aliasing of the hologram, making the AS algorithm hard to realize and accurate phase analysis difficult to conduct. Here, we present a hybrid reconstruction algorithm, combining Fresnel reconstruction in spatial domain with the AS algorithm in frequency domain, to solve aliasing by spatial filtering. Through simulation, we demonstrate the feasibility and superiority of the hybrid algorithm and verified the precision (10-3 rad) of the hybrid algorithm with spectrum aliasing. We extract phase distributions from normal urothelial and bladder cancer tissues by the hybrid algorithm and make quantitative analysis through histogram and standard deviation. The result shows the hybrid algorithm in off-axis DH has great advantage for the high-precision phase extraction of tissues and supplies significant information for cancer diagnosis.
Collapse
|
8
|
Automated red blood cells extraction from holographic images using fully convolutional neural networks. BIOMEDICAL OPTICS EXPRESS 2017; 8:4466-4479. [PMID: 29082078 PMCID: PMC5654793 DOI: 10.1364/boe.8.004466] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2017] [Revised: 08/07/2017] [Accepted: 08/23/2017] [Indexed: 05/22/2023]
Abstract
In this paper, we present two models for automatically extracting red blood cells (RBCs) from RBCs holographic images based on a deep learning fully convolutional neural network (FCN) algorithm. The first model, called FCN-1, only uses the FCN algorithm to carry out RBCs prediction, whereas the second model, called FCN-2, combines the FCN approach with the marker-controlled watershed transform segmentation scheme to achieve RBCs extraction. Both models achieve good segmentation accuracy. In addition, the second model has much better performance in terms of cell separation than traditional segmentation methods. In the proposed methods, the RBCs phase images are first numerically reconstructed from RBCs holograms recorded with off-axis digital holographic microscopy. Then, some RBCs phase images are manually segmented and used as training data to fine-tune the FCN. Finally, each pixel in new input RBCs phase images is predicted into either foreground or background using the trained FCN models. The RBCs prediction result from the first model is the final segmentation result, whereas the result from the second model is used as the internal markers of the marker-controlled transform algorithm for further segmentation. Experimental results show that the given schemes can automatically extract RBCs from RBCs phase images and much better RBCs separation results are obtained when the FCN technique is combined with the marker-controlled watershed segmentation algorithm.
Collapse
|
9
|
Enhancement of short coherence digital holographic microscopy by optical clearing. BIOMEDICAL OPTICS EXPRESS 2017; 8:2036-2054. [PMID: 28736654 PMCID: PMC5516810 DOI: 10.1364/boe.8.002036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2017] [Revised: 02/26/2017] [Accepted: 02/27/2017] [Indexed: 06/07/2023]
Abstract
In this work, we used a short coherence digital holographic microscopy system to demonstrate cross-talk noise suppression and imaging performance enhancement by optical clearing. Performance of the system on both phantom and in vitro porcine skin tissues before and after the treatment of 70% v./v. glycerol-saline solution was investigated. Our results showed that optical clearing effectively inhibits the cross-talk noise and improves the image quality in the deep of the in vitro porcine skin tissues. The imaging depth was increased by about 30% after topical application of the glycerol-saline solution for 30 min.
Collapse
|
10
|
Changes in optical properties of electroporated cells as revealed by digital holographic microscopy. BIOMEDICAL OPTICS EXPRESS 2017; 8:2222-2234. [PMID: 28736667 PMCID: PMC5516823 DOI: 10.1364/boe.8.002222] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2017] [Revised: 03/12/2017] [Accepted: 03/13/2017] [Indexed: 05/16/2023]
Abstract
Changes in optical and shape-related characteristics of B16F10 cells after electroporation were investigated using digital holographic microscopy (DHM). Bipolar rectangular pulses specific for electrochemotherapy were used. Electroporation was performed in an "off-axis" DHM set-up without using exogenous markers. Two types of cell parameters were monitored seconds and minutes after pulse train application: parameters addressing a specifically defined area of the cell (refractive index and cell height) and global cell parameters (projected area, optical phase shift profile and dry mass). The biphasic behavior of cellular parameters was explained by water and mannitol dynamics through the electropermeabilized cell membrane.
Collapse
|
11
|
Label-free fingerprinting of tumor cells in bulk flow using inline digital holographic microscopy. BIOMEDICAL OPTICS EXPRESS 2017; 8:536-554. [PMID: 28270966 PMCID: PMC5330580 DOI: 10.1364/boe.8.000536] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2016] [Revised: 12/21/2016] [Accepted: 12/22/2016] [Indexed: 05/19/2023]
Abstract
Large-scale and label-free phenotyping of cells holds great promise in medicine, especially in cancer diagnostics and prognosis. Here, we introduce inline digital holography microscopy for volumetric imaging of cells in bulk flow and fingerprinting of flowing tumor cells based on two metrics, in-focus scattered intensity and cell diameter. Using planar distribution of immobilized particles, we identify the optimal recording distance and microscope objective magnification that minimizes the error in measurement of particle position, size and scattered intensity. Using the optimized conditions and the two metrics, we demonstrate the capacity to enumerate and fingerprint more than 100,000 cells. Finally, we highlight the power of our label-free and high throughput technology by characterizing breast tumor cell lines with different metastatic potentials and distinguishing drug resistant ovarian cancer cells from their parental cell line.
Collapse
|
12
|
Holographic tomography with scanning of illumination: space-domain reconstruction for spatially invariant accuracy. BIOMEDICAL OPTICS EXPRESS 2016; 7:4086-4101. [PMID: 27867717 PMCID: PMC5102545 DOI: 10.1364/boe.7.004086] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2016] [Revised: 08/11/2016] [Accepted: 08/23/2016] [Indexed: 05/25/2023]
Abstract
The paper presents two novel, space-domain reconstruction algorithms for holographic tomography utilizing scanning of illumination and a fixed detector that is highly suitable for imaging of living biomedical specimens. The first proposed algorithm is an adaptation of the filtered backpropagation to the scanning illumination tomography. Its space-domain implementation enables avoiding the error-prone interpolation in the Fourier domain, which is a significant problem of the state-of-the-art tomographic algorithm. The second proposed algorithm is a modified version of the former, which ensures the spatially invariant reconstruction accuracy. The utility of the proposed algorithms is demonstrated with numerical simulations and experimental measurement of a cancer cell.
Collapse
|
13
|
Aperture scanning Fourier ptychographic microscopy. BIOMEDICAL OPTICS EXPRESS 2016; 7:3140-50. [PMID: 27570705 PMCID: PMC4986821 DOI: 10.1364/boe.7.003140] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2016] [Revised: 06/23/2016] [Accepted: 07/17/2016] [Indexed: 05/05/2023]
Abstract
Fourier ptychographic microscopy (FPM) is implemented through aperture scanning by an LCOS spatial light modulator at the back focal plane of the objective lens. This FPM configuration enables the capturing of the complex scattered field for a 3D sample both in the transmissive mode and the reflective mode. We further show that by combining with the compressive sensing theory, the reconstructed 2D complex scattered field can be used to recover the 3D sample scattering density. This implementation expands the scope of application for FPM and can be beneficial for areas such as tissue imaging and wafer inspection.
Collapse
|
14
|
Cell morphology-based classification of red blood cells using holographic imaging informatics. BIOMEDICAL OPTICS EXPRESS 2016; 7:2385-99. [PMID: 27375953 PMCID: PMC4918591 DOI: 10.1364/boe.7.002385] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2016] [Revised: 05/22/2016] [Accepted: 05/23/2016] [Indexed: 05/23/2023]
Abstract
We present methods that automatically select a linear or nonlinear classifier for red blood cell (RBC) classification by analyzing the equality of the covariance matrices in Gabor-filtered holographic images. First, the phase images of the RBCs are numerically reconstructed from their holograms, which are recorded using off-axis digital holographic microscopy (DHM). Second, each RBC is segmented using a marker-controlled watershed transform algorithm and the inner part of the RBC is identified and analyzed. Third, the Gabor wavelet transform is applied to the segmented cells to extract a series of features, which then undergo a multivariate statistical test to evaluate the equality of the covariance matrices of the different shapes of the RBCs using selected features. When these covariance matrices are not equal, a nonlinear classification scheme based on quadratic functions is applied; otherwise, a linear classification is applied. We used the stomatocyte, discocyte, and echinocyte RBC for classifier training and testing. Simulation results demonstrated that 10 of the 14 RBC features are useful in RBC classification. Experimental results also revealed that the covariance matrices of the three main RBC groups are not equal and that a nonlinear classification method has a much lower misclassification rate. The proposed automated RBC classification method has the potential for use in drug testing and the diagnosis of RBC-related diseases.
Collapse
|
15
|
Signal enhanced holographic fluorescence microscopy with guide-star reconstruction. BIOMEDICAL OPTICS EXPRESS 2016; 7:1271-83. [PMID: 27446653 PMCID: PMC4929639 DOI: 10.1364/boe.7.001271] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Revised: 03/03/2016] [Accepted: 03/03/2016] [Indexed: 05/23/2023]
Abstract
We propose a signal enhanced guide-star reconstruction method for holographic fluorescence microscopy. In the late 00's, incoherent digital holography started to be vigorously studied by several groups to overcome the limitations of conventional digital holography. The basic concept of incoherent digital holography is to acquire the complex hologram from incoherent light by utilizing temporal coherency of a spatially incoherent light source. The advent of incoherent digital holography opened new possibility of holographic fluorescence microscopy (HFM), which was difficult to achieve with conventional digital holography. However there has been an important issue of low and noisy signal in HFM which slows down the system speed and degrades the imaging quality. When guide-star reconstruction is adopted, the image reconstruction gives an improved result compared to the conventional propagation reconstruction method. The guide-star reconstruction method gives higher imaging signal-to-noise ratio since the acquired complex point spread function provides optimal system-adaptive information and can restore the signal buried in the noise more efficiently. We present theoretical explanation and simulation as well as experimental results.
Collapse
|
16
|
Lensfree diffractive tomography for the imaging of 3D cell cultures. BIOMEDICAL OPTICS EXPRESS 2016; 7:949-62. [PMID: 27231600 PMCID: PMC4866467 DOI: 10.1364/boe.7.000949] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2015] [Revised: 12/18/2015] [Accepted: 01/15/2016] [Indexed: 05/05/2023]
Abstract
New microscopes are needed to help realize the full potential of 3D organoid culture studies. In order to image large volumes of 3D organoid cultures while preserving the ability to catch every single cell, we propose a new imaging platform based on lensfree microscopy. We have built a lensfree diffractive tomography setup performing multi-angle acquisitions of 3D organoid culture embedded in Matrigel and developed a dedicated 3D holographic reconstruction algorithm based on the Fourier diffraction theorem. With this new imaging platform, we have been able to reconstruct a 3D volume as large as 21.5 mm (3) of a 3D organoid culture of prostatic RWPE1 cells showing the ability of these cells to assemble in 3D intricate cellular network at the mesoscopic scale. Importantly, comparisons with 2D images show that it is possible to resolve single cells isolated from the main cellular structure with our lensfree diffractive tomography setup.
Collapse
|
17
|
Dynamics of cell and tissue growth acquired by means of extended field of view lensfree microscopy. BIOMEDICAL OPTICS EXPRESS 2016; 7:512-524. [PMID: 26977359 PMCID: PMC4771468 DOI: 10.1364/boe.7.000512] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Revised: 09/16/2015] [Accepted: 09/24/2015] [Indexed: 06/05/2023]
Abstract
In this paper, we discuss a new methodology based on lensfree imaging to perform wound healing assay with unprecedented statistics. Our video lensfree microscopy setup is a simple device featuring only a CMOS sensor and a semi coherent illumination system. Yet it is a powerful mean for the real-time monitoring of cultivated cells. It presents several key advantages, e.g. integration into standard incubator, compatibility with standard cell culture protocol, simplicity and ease of use. It can perform the follow-up in a large field of view (25 mm(2)) of several crucial parameters during the culture of cells i.e. their motility, their proliferation rate or their death. Consequently the setup can gather large statistics both in space and time. Here we uses this facility in the context of wound healing assay to perform label-free measurements of the velocities of the fronts of proliferation of the cell layer as a function of time by means of particle image velocimetry (PIV) processing. However, for such tissue growth experiments, the field of view of 25 mm(2) remains not sufficient and results can be biased depending on the position of the device with respect to the recipient of the cell culture. Hence, to conduct exhaustive wound healing assays, we propose to enlarge the field of view up to 10 cm(2) through a raster scan, by moving the source/sensor with respect to the Petri dish. We have performed acquisitions of wound healing assay (keratinocytes HaCaT) both in real-time (25 mm(2)) and in final point (10 cm(2)) to assess the combination of velocimetry measurements and final point wide field imaging. In the future, we aim at combining directly our extended field of view acquisitions (>10 cm(2)) with real time ability inside the incubator.
Collapse
|
18
|
Towards new applications using capillary waveguides. BIOMEDICAL OPTICS EXPRESS 2015; 6:4619-31. [PMID: 26713182 PMCID: PMC4679242 DOI: 10.1364/boe.6.004619] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2015] [Revised: 10/26/2015] [Accepted: 10/29/2015] [Indexed: 05/10/2023]
Abstract
In this paper we demonstrate the enhancement of the sensing capabilities of glass capillaries. We exploit their properties as optical and acoustic waveguides to transform them potentially into high resolution minimally invasive endoscopic devices. We show two possible applications of silica capillary waveguides demonstrating fluorescence and optical-resolution photoacoustic imaging using a single 330 μm-thick silica capillary. A nanosecond pulsed laser is focused and scanned in front of a capillary by digital phase conjugation through the silica annular ring of the capillary, used as an optical waveguide. We demonstrate optical-resolution photoacoustic images of a 30 μm-thick nylon thread using the water-filled core of the same capillary as an acoustic waveguide, resulting in a fully passive endoscopic device. Moreover, fluorescence images of 1.5 μm beads are obtained collecting the fluorescence signal through the optical waveguide. This kind of silica-capillary waveguide together with wavefront shaping techniques such as digital phase conjugation, paves the way to minimally invasive multi-modal endoscopy.
Collapse
|
19
|
Quantitative analysis of platelets aggregates in 3D by digital holographic microscopy. BIOMEDICAL OPTICS EXPRESS 2015; 6:3556-63. [PMID: 26417523 PMCID: PMC4574679 DOI: 10.1364/boe.6.003556] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2015] [Revised: 07/20/2015] [Accepted: 08/14/2015] [Indexed: 05/12/2023]
Abstract
Platelet spreading and retraction play a pivotal role in the platelet plugging and the thrombus formation. In routine laboratory, platelet function tests include exhaustive information about the role of the different receptors present at the platelet surface without information on the 3D structure of platelet aggregates. In this work, we develop, a method in Digital Holographic Microscopy (DHM) to characterize the platelet and aggregate 3D shapes using the quantitative phase contrast imaging. This novel method is suited to the study of platelets physiology in clinical practice as well as the development of new drugs.
Collapse
|
20
|
Influence of defocus on quantitative analysis of microscopic objects and individual cells with digital holography. BIOMEDICAL OPTICS EXPRESS 2015; 6:2067-75. [PMID: 26114029 PMCID: PMC4473744 DOI: 10.1364/boe.6.002067] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2015] [Revised: 04/20/2015] [Accepted: 05/01/2015] [Indexed: 05/18/2023]
Abstract
Digital holography offers a unique method for studying microscopic objects using quantitative measurements of the optical phase delays of transmitted light. The optical phase may be integrated across the object to produce an optical volume measurement, a parameter related to dry mass by a simple scaling factor. While digital holography is useful for comparing the properties of microscopic objects, especially cells, we show here that quantitative comparisons of optical phase can be influenced by the focal plane of the measurement. Although holographic images can be refocused digitally using Fresnel propagation, ambiguity can result if this aspect is not carefully controlled. We demonstrate that microscopic objects can be accurately profiled by employing a digital refocusing method to analyze phase profiles of polystyrene microspheres and red blood cells.
Collapse
|
21
|
Biodynamic imaging of live porcine oocytes, zygotes and blastocysts for viability assessment in assisted reproductive technologies. BIOMEDICAL OPTICS EXPRESS 2015; 6:963-76. [PMID: 25798318 PMCID: PMC4361448 DOI: 10.1364/boe.6.000963] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Revised: 02/13/2015] [Accepted: 02/17/2015] [Indexed: 05/23/2023]
Abstract
The success of assisted reproductive technologies relies on accurate assessment of reproductive viability at successive stages of development for oocytes and embryos. The current scoring system used to select good-quality oocytes relies on morphologically observable traits and hence is indirect and subjective. Biodynamic imaging may provide an objective approach to oocyte and embryo assessment by measuring physiologically-relevant dynamics. Biodynamic imaging is a coherence-gated approach to 3D tissue imaging that uses digital holography to perform low-coherence speckle interferometry to capture dynamic light scattering from intracellular motions. The changes in intracellular activity during cumulus oocyte complex maturation, before and after in vitro fertilization, and the subsequent development of the zygote and blastocyst provide a new approach to the assessment of preimplant candidates.
Collapse
|
22
|
Relation between speckle decorrelation and optical phase conjugation (OPC)-based turbidity suppression through dynamic scattering media: a study on in vivo mouse skin. BIOMEDICAL OPTICS EXPRESS 2015; 6:72-85. [PMID: 25657876 PMCID: PMC4317115 DOI: 10.1364/boe.6.000072] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2014] [Revised: 11/19/2014] [Accepted: 12/03/2014] [Indexed: 05/19/2023]
Abstract
Light scattering in biological tissue significantly limits the accessible depth for localized optical interrogation and deep-tissue optical imaging. This challenge can be overcome by exploiting the time-reversal property of optical phase conjugation (OPC) to reverse multiple scattering events or suppress turbidity. However, in living tissue, scatterers are highly movable and the movement can disrupt time-reversal symmetry when there is a latency in the OPC playback. In this paper, we show that the motion-induced degradation of the OPC turbidity-suppression effect through a dynamic scattering medium shares the same decorrelation time constant as that determined from speckle intensity autocorrelation - a popular conventional measure of scatterer movement. We investigated this decorrelation characteristic time through a 1.5-mm-thick dorsal skin flap of a living mouse and found that it ranges from 50 ms to 2.5 s depending on the level of immobilization. This study provides information on relevant time scales for applying OPC to living tissues.
Collapse
|
23
|
Enhanced quantitative phase imaging in self-interference digital holographic microscopy using an electrically focus tunable lens. BIOMEDICAL OPTICS EXPRESS 2014; 5:4213-22. [PMID: 25574433 PMCID: PMC4285600 DOI: 10.1364/boe.5.004213] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2014] [Revised: 10/11/2014] [Accepted: 10/17/2014] [Indexed: 05/02/2023]
Abstract
Self-interference digital holographic microscopy (DHM) has been found particular suitable for simplified quantitative phase imaging of living cells. However, a main drawback of the self-interference DHM principle are scattering patterns that are induced by the coherent nature of the laser light which affect the resolution for detection of optical path length changes. We present a simple and efficient technique for the reduction of coherent disturbances in quantitative phase images. Therefore, amplitude and phase of the sample illumination are modulated by an electrically focus tunable lens. The proposed method is in particular convenient with the self-interference DHM concept. Results from the characterization of the method show that a reduction of coherence induced disturbances up to 70 percent can be achieved. Finally, the performance for enhanced quantitative imaging of living cells is demonstrated.
Collapse
|
24
|
Off-axis digital holographic camera for quantitative phase microscopy. BIOMEDICAL OPTICS EXPRESS 2014; 5:1721-30. [PMID: 24940535 PMCID: PMC4052906 DOI: 10.1364/boe.5.001721] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2014] [Revised: 04/24/2014] [Accepted: 04/27/2014] [Indexed: 05/21/2023]
Abstract
We propose and experimentally demonstrate a digital holographic camera which can be attached to the camera port of a conventional microscope for obtaining digital holograms in a self-reference configuration, under short coherence illumination and in a single shot. A thick holographic grating filters the beam containing the sample information in two dimensions through diffraction. The filtered beam creates the reference arm of the interferometer. The spatial filtering method, based on the high angular selectivity of the thick grating, reduces the alignment sensitivity to angular displacements compared with pinhole based Fourier filtering. The addition of a thin holographic grating alters the coherence plane tilt introduced by the thick grating so as to create high-visibility interference over the entire field of view. The acquired full-field off-axis holograms are processed to retrieve the amplitude and phase information of the sample. The system produces phase images of cheek cells qualitatively similar to phase images extracted with a standard commercial DHM.
Collapse
|
25
|
Fully automated digital holographic processing for monitoring the dynamics of a vesicle suspension under shear flow. BIOMEDICAL OPTICS EXPRESS 2014; 5:1554-68. [PMID: 24877015 PMCID: PMC4026899 DOI: 10.1364/boe.5.001554] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2014] [Revised: 04/10/2014] [Accepted: 04/11/2014] [Indexed: 05/16/2023]
Abstract
We investigate the dynamics of a vesicle suspension under shear flow between plates using DHM with a spatially reduced coherent source. Holograms are grabbed at a frequency of 24 frames/sec. The distribution of the vesicle suspension is obtained after numerical processing of the digital holograms sequence resulting in a 4D distribution. Obtaining this distribution is not straightforward and requires special processing to automate the analysis. We present an original method that fully automates the analysis and provides distributions that are further analyzed to extract physical properties of the fluid. Details of the numerical implementation, as well as sample experimental results are presented.
Collapse
|
26
|
Opposed-view dark-field digital holographic microscopy. BIOMEDICAL OPTICS EXPRESS 2014; 5:728-36. [PMID: 24688809 PMCID: PMC3959838 DOI: 10.1364/boe.5.000728] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2013] [Revised: 01/22/2014] [Accepted: 02/05/2014] [Indexed: 05/05/2023]
Abstract
Scattering and absorption belong to the major problems in imaging the internal layers of a biological specimen. Due to the structural inhomogeneity of the specimen, the distribution of the structures in the upper layers of a given internal structure of interest is different from the lower layers that may result in different interception of scattered light, falling into the angular aperture of the microscope objective, from the object in each imaging view. Therefore, different spatial frequencies of the scattered light can be acquired from different (top and bottom) views. We have arranged an opposed-view dark-field digital holographic microscope (DHM) to collect the scattered light concurrently from both views with the aim to increase the contrast of internal structures and improve the signal-to-noise ratio. Implementing a DHM system gives the possibility to implement digital refocusing process and obtain multilayer images from each side without a depth scan of the object. The method is explained and the results are presented exemplary for a Drosophila embryo.
Collapse
|
27
|
4D tracking of clinical seminal samples for quantitative characterization of motility parameters. BIOMEDICAL OPTICS EXPRESS 2014; 5:690-700. [PMID: 24688806 PMCID: PMC3959837 DOI: 10.1364/boe.5.000690] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2013] [Revised: 12/06/2013] [Accepted: 12/30/2013] [Indexed: 05/02/2023]
Abstract
In this paper we investigate the use of a digital holographic microscope, with partial spatial coherent illumination, for the automated detection and tracking of spermatozoa. This in vitro technique for the analysis of quantitative parameters is useful for assessment of semen quality. In fact, thanks to the capabilities of digital holography, the developed algorithm allows us to resolve in-focus amplitude and phase maps of the cells under study, independently of focal plane of the sample image. We have characterized cell motility on clinical samples of seminal fluid. In particular, anomalous sperm cells were characterized and the quantitative motility parameters were compared to those of normal sperm.
Collapse
|
28
|
Multiple contrast metrics from the measurements of a digital confocal microscope. BIOMEDICAL OPTICS EXPRESS 2013; 4:1091-103. [PMID: 23847735 PMCID: PMC3704091 DOI: 10.1364/boe.4.001091] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2013] [Revised: 05/30/2013] [Accepted: 06/03/2013] [Indexed: 05/15/2023]
Abstract
We describe various methods to process the data collected with a digital confocal microscope (DCM) in order to get more information than what we could get from a conventional confocal system. Different metrics can be extracted from the data collected with the DCM in order to produce images that reveal different features of the sample. The integrated phase of the scattered field allows for the three-dimensional reconstruction of the refractive index distribution. In a similar way, the integration of the field intensity yields the absorption coefficient distribution. The deflection of the digitally reconstructed focus reveals the sample-induced aberrations and the RMS width of the focus gives an indication on the local scattering coefficient. Finally, in addition to the conventional confocal metric, which consists in integrating the intensity within the pinhole, the DCM allows for the measurement of the phase within the pinhole. This metrics is close to the whole-field integrated phase and thus gives a qualitative image of the refractive index distribution.
Collapse
|
29
|
Digital holographic microscopy of the myelin figure structural dynamics and the effect of thermal gradient. BIOMEDICAL OPTICS EXPRESS 2013; 4:950-957. [PMID: 23760951 PMCID: PMC3675873 DOI: 10.1364/boe.4.000950] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/26/2013] [Revised: 04/11/2013] [Accepted: 04/19/2013] [Indexed: 06/02/2023]
Abstract
Myelin figures (MFs) are cylindrical multilamellar lipid tubes that can be found in various healthy and diseased living cells. Their formation and dynamics involve some of the most mysterious configurations that lipid molecules can adopt under certain conditions. They have been studied with different microscopy methods. Due to the frequent coiling of their structure, the usual methods of microscopy fail to give precise quantitative information about their dynamics. In this paper, we introduced Digital Holographic Microscopy (DHM) as a useful method to calculate the precise dynamical volume, thickness, surface and length of the myelin figures. As an example of DHM imaging of myelin figures, their structure and growth rate in the presence and absence of temperature gradient have been studied in this work. We showed that the thickness of a myelin figure can be changed during the first few seconds. However, after approximately ten seconds, the thickness stabilizes and does not alter significantly. We further studied the effect of the thermal gradient on the length growth. The calculation of the length growth from the measurement of the myelin figure volume shows that the length (L) grows in time (t) as [Formula: see text]at the early stage of the myelin protrusion in both the presence and the absence of the thermal gradient. However, thermal gradient facilitates the growth and increases its rate.
Collapse
|
30
|
High-resolution, lensless endoscope based on digital scanning through a multimode optical fiber. BIOMEDICAL OPTICS EXPRESS 2013; 4:260-70. [PMID: 23411747 PMCID: PMC3567713 DOI: 10.1364/boe.4.000260] [Citation(s) in RCA: 111] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2012] [Revised: 01/08/2013] [Accepted: 01/08/2013] [Indexed: 05/18/2023]
Abstract
We propose and experimentally demonstrate an ultra-thin rigid endoscope (450 μm diameter) based on a passive multimode optical fiber. We use digital phase conjugation to overcome the modal scrambling of the fiber to tightly focus and scan the laser light at its distal end. By exploiting the maximum number of modes available, sub-micron resolution, high quality fluorescence images of neuronal cells were acquired. The imaging system is evaluated in terms of fluorescence collection efficiency, resolution and field of view. The small diameter of the proposed endoscope, along with its high quality images offer an opportunity for minimally invasive medical endoscopic imaging and diagnosis based on cellular phenotype via direct tissue penetration.
Collapse
|
31
|
Simultaneous amplitude-contrast and phase-contrast surface plasmon resonance imaging by use of digital holography. BIOMEDICAL OPTICS EXPRESS 2012; 3:3190-3202. [PMID: 23243569 PMCID: PMC3521296 DOI: 10.1364/boe.3.003190] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2012] [Revised: 10/12/2012] [Accepted: 11/04/2012] [Indexed: 05/30/2023]
Abstract
The surface plasmon resonance imaging technique provides a tool that allows high-throughput analysis and real-time kinetic measurement. A simultaneous amplitude-contrast and phase-contrast surface plasmon resonance imaging method is presented. The amplitude-contrast and phase-contrast images are simultaneously obtained by use of digital holography. The detection sensitivity of amplitude-contrast imaging and phase-contrast imaging can compensate for each other. Thus, the detectable sample components may cover a wider range of refractive index values for the simultaneous amplitude-contrast and phase-contrast imaging method than for the phase-contrast imaging method or amplitude-contrast imaging method. A detailed description of the theory and an experiment of monitoring the evaporation process of a drop of NaCl injection in real time are presented. In addition, the amplitude-contrast image has less coherent noise by digital holography.
Collapse
|
32
|
Tissue dynamics spectroscopy for phenotypic profiling of drug effects in three-dimensional culture. BIOMEDICAL OPTICS EXPRESS 2012; 3:2825-41. [PMID: 23162721 PMCID: PMC3493238 DOI: 10.1364/boe.3.002825] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2012] [Revised: 10/03/2012] [Accepted: 10/03/2012] [Indexed: 05/04/2023]
Abstract
Coherence-gated dynamic light scattering captures cellular dynamics through ultra-low-frequency (0.005-5 Hz) speckle fluctuations and Doppler shifts that encode a broad range of cellular and subcellular motions. The dynamic physiological response of tissues to applied drugs is the basis for a new type of phenotypic profiling for drug screening on multicellular tumor spheroids. Volumetrically resolved tissue-response fluctuation spectrograms act as fingerprints that are segmented through feature masks into high-dimensional feature vectors. Drug-response clustering is achieved through multidimensional scaling with simulated annealing to construct phenotypic drug profiles that cluster drugs with similar responses. Hypoxic vs. normoxic tissue responses present two distinct phenotypes with differentiated responses to environmental perturbations and to pharmacological doses.
Collapse
|
33
|
In vivo imaging and quantitative analysis of zebrafish embryos by digital holographic microscopy. BIOMEDICAL OPTICS EXPRESS 2012; 3:2623-35. [PMID: 23082301 PMCID: PMC3470009 DOI: 10.1364/boe.3.002623] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2012] [Revised: 09/14/2012] [Accepted: 09/14/2012] [Indexed: 05/15/2023]
Abstract
Digital holographic microscopy (DHM) has been applied extensively to in vitro studies of different living cells. In this paper, we present a novel application of an off-axis DHM system to in vivo study of the development of zebrafish embryos. Even with low magnification microscope objectives, the morphological structures and individual cell types inside developing zebrafish embryos can be clearly observed from reconstructed amplitude images. We further study the dynamic process of blood flow in zebrafish embryos. A calibration routine and post-processing procedures are developed to quantify physiological parameters at different developmental stages. We measure quantitatively the blood flow as well as the heart rate to study the effects of elevated D-glucose (abnormal condition) on circulatory and cardiovascular systems of zebrafish embryos. To enhance our ability to use DHM as a quantitative tool for potential high throughput screening application, the calibration and post-processing algorithms are incorporated into an automated processing software. Our results show that DHM is an excellent non-invasive imaging technique for visualizing the cellular dynamics of organogenesis of zebrafish embryos in vivo.
Collapse
|
34
|
Measurement of orientation and susceptibility ratios using a polarization-resolved second-harmonic generation holographic microscope. BIOMEDICAL OPTICS EXPRESS 2012; 3:2004-2011. [PMID: 23024896 PMCID: PMC3447544 DOI: 10.1364/boe.3.002004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2012] [Revised: 07/30/2012] [Accepted: 07/31/2012] [Indexed: 05/26/2023]
Abstract
Three-dimensional second-harmonic fields, sample orientation, and susceptibility ratios of biological samples are measured using polarization-resolved second-harmonic generation (SHG) microscopy. The three-dimensional (3D) polarization is gathered by measurement of a series of holograms for which excitation and analyzer polarizations are systematically varied, and the 3D SHG field is recovered through numerical back propagation. Harmonophore orientation is resolved in 3D from a sub-set of polarization-resolved SHG holograms. We further expand on previous approaches for the determination of susceptibility ratios, adding the calculation of multiple ratio values to allow intrinsic verification.
Collapse
|
35
|
Short-coherence off-axis holographic phase microscopy of live cell dynamics. BIOMEDICAL OPTICS EXPRESS 2012; 3:2184-9. [PMID: 23024912 PMCID: PMC3447560 DOI: 10.1364/boe.3.002184] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2012] [Revised: 08/22/2012] [Accepted: 08/22/2012] [Indexed: 05/07/2023]
Abstract
We demonstrate a single-shot holographic phase microscope that combines short-coherence laser pulses with an off-axis geometry. By introducing a controlled pulse front tilt, ultrashort pulses are made to interfere over a large field-of-view without loss of fringe contrast. With this microscope, quantitative phase images of live cells can be recorded in a full-field geometry without moving parts. We perform phase imaging of HEK293 cells, to study the dynamics of cell volume regulation in response to an osmotic shock.
Collapse
|
36
|
Holographic coherent anti-Stokes Raman scattering bio-imaging. BIOMEDICAL OPTICS EXPRESS 2012; 3:1744-1749. [PMID: 22808443 PMCID: PMC3395496 DOI: 10.1364/boe.3.001744] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2012] [Revised: 06/25/2012] [Accepted: 06/25/2012] [Indexed: 05/28/2023]
Abstract
CARS holography captures both the amplitude and the phase of a complex anti-Stokes field, and can perform three-dimensional imaging by digitally focusing onto different depths inside a specimen. The application of CARS holography for bio-imaging is demonstrated. It is shown that holographic CARS imaging of sub-cellular components in live HeLa cells can be achieved.
Collapse
|
37
|
Enhanced robustness digital holographic microscopy for demanding environment of space biology. BIOMEDICAL OPTICS EXPRESS 2012; 3:313-26. [PMID: 22312584 PMCID: PMC3269848 DOI: 10.1364/boe.3.000313] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2011] [Revised: 01/06/2012] [Accepted: 01/12/2012] [Indexed: 05/08/2023]
Abstract
We describe an optimized digital holographic microscopy system (DHM) suitable for high-resolution visualization of living cells under conditions of altered macroscopic mechanical forces such as those that arise from changes in gravitational force. Experiments were performed on both a ground-based microgravity simulation platform known as the random positioning machine (RPM) as well as during a parabolic flight campaign (PFC). Under these conditions the DHM system proved to be robust and reliable. In addition, the stability of the system during disturbances in gravitational force was further enhanced by implementing post-processing algorithms that best exploit the intrinsic advantages of DHM for hologram autofocusing and subsequent image registration. Preliminary results obtained in the form of series of phase images point towards sensible changes of cytoarchitecture under states of altered gravity.
Collapse
|
38
|
Field-portable reflection and transmission microscopy based on lensless holography. BIOMEDICAL OPTICS EXPRESS 2011; 2:2721-30. [PMID: 21991559 PMCID: PMC3184880 DOI: 10.1364/boe.2.002721] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2011] [Revised: 08/11/2011] [Accepted: 08/11/2011] [Indexed: 05/19/2023]
Abstract
We demonstrate a lensfree dual-mode holographic microscope that can image specimens in both transmission and reflection geometries using in-line transmission and off-axis reflection holography, respectively. This field-portable dual-mode holographic microscope has a weight of ~200 g with dimensions of 15 x 5.5 x 5cm, where a laser source is powered by two batteries. Based on digital in-line holography, our transmission microscope achieves a sub-pixel lateral resolution of ≤2 µm over a wide field-of-view (FOV) of ~24 mm(2) due to its unit fringe magnification geometry. Despite its simplicity and ease of operation, in-line transmission geometry is not suitable to image dense or connected objects such as tissue slides since the reference beam gets distorted causing severe aberrations in reconstruction of such objects. To mitigate this challenge, on the same cost-effective and field-portable assembly we built a lensless reflection mode microscope based on digital off-axis holography where a beam-splitter is used to interfere a tilted reference wave with the reflected light from the object surface, creating an off-axis hologram of the specimens on a CMOS sensor-chip. As a result of the reduced space-bandwidth product of the off-axis geometry compared to its in-line counterpart, the imaging FOV of our reflection mode is reduced to ~9 mm(2), while still achieving a similar sub-pixel resolution of ≤2 µm. We tested the performance of this compact dual-mode microscopy unit by imaging a US-air force resolution test target, various micro-particles as well as a histopathology slide corresponding to skin tissue. Due to its compact, cost-effective, and lightweight design, this dual-mode lensless holographic microscope might especially be useful for field-use or for conducting microscopic analysis in resource-poor settings.
Collapse
|
39
|
Holographic UV laser microsurgery. BIOMEDICAL OPTICS EXPRESS 2011; 2:2590-2599. [PMID: 21991551 PMCID: PMC3184868 DOI: 10.1364/boe.2.002590] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2011] [Revised: 08/09/2011] [Accepted: 08/09/2011] [Indexed: 05/29/2023]
Abstract
We use a spatial light modulator (SLM) to diffract a single UV laser pulse to ablate multiple points on a Drosophila embryo. This system dynamically generates a phase hologram for ablating a user-defined pattern fast enough to be used with living, and thus moving, tissue. We demonstrate the ability of this single-pulse multi-point system to perform two experiments that are very difficult for conventional microsurgery-isolating single cells in vivo and measuring fast retractions from large incisions.
Collapse
|
40
|
Realistic 3D coherent transfer function inverse filtering of complex fields. BIOMEDICAL OPTICS EXPRESS 2011; 2:2216-30. [PMID: 21833359 PMCID: PMC3149520 DOI: 10.1364/boe.2.002216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2011] [Revised: 06/29/2011] [Accepted: 06/30/2011] [Indexed: 05/02/2023]
Abstract
We present a novel technique for three-dimensional (3D) image processing of complex fields. It consists in inverting the coherent image formation by filtering the complex spectrum with a realistic 3D coherent transfer function (CTF) of a high-NA digital holographic microscope. By combining scattering theory and signal processing, the method is demonstrated to yield the reconstruction of a scattering object field. Experimental reconstructions in phase and amplitude are presented under non-design imaging conditions. The suggested technique is best suited for an implementation in high-resolution diffraction tomography based on sample or illumination rotation.
Collapse
|
41
|
Dynamic DIC by digital holography microscopy for enhancing phase-contrast visualization. BIOMEDICAL OPTICS EXPRESS 2011; 2:331-44. [PMID: 21339878 PMCID: PMC3038448 DOI: 10.1364/boe.2.000331] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2010] [Revised: 12/10/2010] [Accepted: 01/10/2011] [Indexed: 05/18/2023]
Abstract
Differential image contrast (DIC), through the numerical managing and manipulation of complex wavefronts obtained by digital holography (DH), is investigated. We name the approach Dynamical Differential Holographic Image Contrast (DDHIC). DDHIC dispenses from special optics and/or complex setup configurations with moveable components, as usually occurs in classical DIC, that is not well-suited for investigating objects experiencing dynamic evolution during the measurement. In fact, the technique presented here, is useful for floating samples since it allows, from a single recording, to set a posteriori the best conditions for DIC imaging in conjunction with the numerical focusing feature of DH. By DDHIC, the movies can be easily built-up to offering dynamic representation of phase-contrast along all directions, thus improving the visualization. Furthermore, the dynamic representation is useful for making the proper choice of other key parameters of DIC such as the amount of shear and the bias, with the aim to optimize the visualized phase-contrast imaging as favorite representation for bio-scientists. Investigation is performed on various biological samples.
Collapse
|