1
|
Liang T, Jiang N, Zhou S, Wang X, Xu Y, Wu C, Kirsanov D, Legin A, Wan H, Wang P. Multiplexed all-solid-state ion-sensitive light-addressable potentiometric sensor (ISLAPS) system based on silicone-rubber for physiological ions detection. Anal Chim Acta 2021; 1179:338603. [PMID: 34535249 DOI: 10.1016/j.aca.2021.338603] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Revised: 04/14/2021] [Accepted: 04/30/2021] [Indexed: 10/21/2022]
Abstract
Light-addressable potentiometric sensor (LAPS) has been widely used in biomedical applications since its advent. As a member of the potentiometric sensors, ion-sensitive LAPS (ISLAPS) can be obtained by modifying ion selective sensing membrane on the sensor surface. Compared with the conventional ion-selective electrodes (ISEs) with liquid contact, the all-solid-state ISEs have more advantages such as easy maintenance, more convenient for miniaturization and practical applications. However, the commonly used ion-sensitive membrane (ISM) matrix like PVC has many limitations such as poor adhesion to silicone-based sensor and easy overflow of the plasticizer from the membrane. In this work, LAPS was combined with a variety of ionophore-doped all-solid-state silicone-rubber ISMs for the first time, to establish a program-controlled multiplexed ISLAPS system for physiological ions (Na+, K+, Ca2+ and H+) detection. The silicone-rubber ISMs have better adhesion to silicon-based sensors without containing plasticizers, which can avoid the plasticizer pollution and improve the long-term stability. A layer of poly(3-octylthiophene-2,5-diyl) (P3OT) was pre-modified on the sensor surface to inhibit the formation of an aqueous layer and improve the sensor lifetime. With the aid of a translation stage, the light spot automatically illuminated the detection sites in sequence, and the response of the four ions could be obtained in one measurement within 1 min. The proposed multiplexed ISLAPS has good sensitivity with micromolar limit of detection (LOD), good selectivity and long-term stability (more than 3 months). The results of the real Dulbecco's Modified Eagle Medium (DMEM) sample detection proved that the ISLAPS system can be used for the physiological ions detection, and is promising to realize a multi-parameter microphysiometer.
Collapse
Affiliation(s)
- Tao Liang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Nan Jiang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Shuqi Zhou
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Xinyi Wang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Yingke Xu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Chunsheng Wu
- Institute of Medical Engineering, School of Basic Medical Sciences, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Dmitry Kirsanov
- Institute of Chemistry, Mendeleev Center, St. Petersburg State University, St. Petersburg, 199034, Russia
| | - Andrey Legin
- Institute of Chemistry, Mendeleev Center, St. Petersburg State University, St. Petersburg, 199034, Russia
| | - Hao Wan
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China.
| | - Ping Wang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China.
| |
Collapse
|
2
|
Dantism S, Röhlen D, Selmer T, Wagner T, Wagner P, Schöning MJ. Quantitative differential monitoring of the metabolic activity of Corynebacterium glutamicum cultures utilizing a light-addressable potentiometric sensor system. Biosens Bioelectron 2019; 139:111332. [PMID: 31132723 DOI: 10.1016/j.bios.2019.111332] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Revised: 04/29/2019] [Accepted: 05/15/2019] [Indexed: 10/26/2022]
Abstract
Applying biosensors for evaluation of the extracellular acidification of microorganisms in various biotechnological fermentation processes is on demand. An early stage detection of disturbances in the production line would avoid costly interventions related to metabolically inactive microorganisms. Furthermore, the determination of the number of living cells through cell plating procedure after cultivations is known as time- and material-consuming. In this work, a differential light-addressable potentiometric sensor (LAPS) system was developed to monitor the metabolic activity of Corynebacterium glutamicum (C. glutamicum ATCC13032) as typical microorganism in fermentation processes. In this context, the number of living cells in suspensions was directly determined utilizing the read-out principle of the LAPS system. The planar sensor surface of the LAPS design allows to fixate 3D-printed multi-chamber structures, which enables differential measurements. In this way, undesirable external influences such as pH variations of the medium and sensor signal drift can be compensated.
Collapse
Affiliation(s)
- Shahriar Dantism
- Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Campus Jülich, 52428, Jülich, Germany; Department of Physics and Astronomy, Soft-Matter Physics and Biophysics Section, KU Leuven, Celestijnenlaan 200 D, 3001, Leuven, Belgium
| | - Désirée Röhlen
- Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Campus Jülich, 52428, Jülich, Germany
| | - Thorsten Selmer
- Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Campus Jülich, 52428, Jülich, Germany
| | - Torsten Wagner
- Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Campus Jülich, 52428, Jülich, Germany; Institute of Complex Systems (ICS-8), Research Centre Jülich GmbH, 52425, Jülich, Germany
| | - Patrick Wagner
- Department of Physics and Astronomy, Soft-Matter Physics and Biophysics Section, KU Leuven, Celestijnenlaan 200 D, 3001, Leuven, Belgium
| | - Michael J Schöning
- Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Campus Jülich, 52428, Jülich, Germany; Institute of Complex Systems (ICS-8), Research Centre Jülich GmbH, 52425, Jülich, Germany.
| |
Collapse
|
3
|
Du L, Wang J, Chen W, Zhao L, Wu C, Wang P. Dual functional extracellular recording using a light-addressable potentiometric sensor for bitter signal transduction. Anal Chim Acta 2018; 1022:106-12. [PMID: 29729730 DOI: 10.1016/j.aca.2018.03.012] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2018] [Revised: 03/05/2018] [Accepted: 03/10/2018] [Indexed: 11/24/2022]
Abstract
This paper presents a dual functional extracellular recording biosensor based on a light-addressable potentiometric sensor (LAPS). The design and fabrication of this biosensor make it possible to record both extracellular membrane potential changes and ATP release from a single taste bud cell for the first time. For detecting ATP release, LAPS chip was functionalized with ATP-sensitive DNA aptamer by covalent immobilization. Taste bud cells isolated from rat were cultured on LAPS surface. When the desired single taste bud cell was illuminated by modulated light, ATP release from single taste bud cells can be measured by recording the shifts of bias voltage-photocurrent curves (I-V curves) when the LAPS chip is working in discrete mode. On the other hand, extracellular membrane potential changes can be monitored by recording the fluctuation of LAPS photocurrent when the LAPS chip is working in continuous mode. The results show this biosensor can effectively record the enhancive effect of the bitter substance and inhibitory effect of the carbenoxolone (CBX) on the extracellular membrane potential changes and ATP release of single taste bud cells. In addition, the inhibitory effect of CBX also confirms LAPS extracellular recordings are originated from bitter signal transduction. It is proved this biosensor is suitable for extracellular recording of ATP release and membrane potential changes of single taste bud cells. It is suggested this biosensor could be applied to investigating taste signal transduction at the single-cell level as well as applied to other types of cells which have similar functions to taste bud cells.
Collapse
|