1
|
Facet-Dependent Photoelectrochemistry on Single Crystal Organic-Inorganic Halide Perovskite Electrodes. CHEMICAL & BIOMEDICAL IMAGING 2023; 1:488-494. [PMID: 37655168 PMCID: PMC10467489 DOI: 10.1021/cbmi.3c00069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 07/09/2023] [Accepted: 07/18/2023] [Indexed: 09/02/2023]
Abstract
Organometallic halide perovskites have garnered significant attention in various fields of material science, particularly solar energy conversion, due to their desirable optoelectronic properties and compatibility with scalable fabrication techniques. It is often unclear, however, how carrier generation and transport within complex polycrystalline films are influenced by variations in local structure. Elucidating how distinct structural motifs within these heterogeneous systems affect behavior could help guide the continued improvement of perovskite-based solar cells. Here, we present studies applying scanning electron microscopy (SECCM) to map solar energy harvesting within well-defined model systems of organometallic halide perovskites. Methylammonium lead bromide (MAPbBr3) single crystals were prepared via a low-temperature solution-based route, and their photoelectrochemical properties were mapped via SECCM using p-benzoquinone (BQ) in dichloromethane as a redox mediator. Correlated SECCM mapping and electron microscopy studies enabled facet-to-facet variations in photoelectrochemical performance to be revealed and carrier transport lengths to be evaluated. The photoelectrochemical behavior observed within individual single crystals was quite heterogeneous, attributable to local variations in crystal structure/orientations, intrafacet junctions, and the presence of other structural defects. These observations underscore the significance of controlling the microstructure of single perovskite crystals, presenting a promising avenue for further enhancement of perovskite-based solar cells.
Collapse
|
2
|
Closed Bipolar Electrode Array for Optical Reporting Reaction-Coupled Electrochemical Sensing and Imaging. Chemistry 2023; 29:e202202687. [PMID: 36316589 DOI: 10.1002/chem.202202687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 10/25/2022] [Accepted: 10/31/2022] [Indexed: 11/05/2022]
Abstract
This review centers on a closed bipolar electrode (BPE) array using an electro-fluorochromism (EFC) or electro-chemiluminescence (ECL) reaction as the reporting reaction. Electrochemical signals at one pole of the closed BPE array can be transduced into the EFC or ECL signals at the opposite pole. Therefore, the current signal of a redox reaction can be easily detected and imaged by monitoring the luminescence signal. Recent developments in closed BPE array-based EFC and ECL sensing and imaging are summarized and discussed in detail. Finally, we consider the challenges and opportunities for improving the spatial resolution of closed BPE array-based electrochemical imaging, and emphasize the important application of this technique to the imaging of cellular activities at the single-cell level.
Collapse
|
3
|
Insights into the Mechanism of Bipolar Electrodeposition of Au Films and Its Application in Visual Detection of Prostate Specific Antigens. BIOSENSORS 2023; 13:158. [PMID: 36831924 PMCID: PMC9953799 DOI: 10.3390/bios13020158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 01/11/2023] [Accepted: 01/16/2023] [Indexed: 06/18/2023]
Abstract
Au particles are commonly used for deposition on the surface of a bipolar electrode (BPE) in order to amplify electrochemical and electrochemiluminescence (ECL) signal because of their excellent conductivity, biocompatibility, and large surface area. In this work, a closed BPE device was fabricated and Au particles were deposited on the two poles of a BPE via bipolar deposition. Results indicated that the electrochemical stability of Au film on the anode part of the BPE and the reduction of AuCl4- to Au on the cathode part of the BPE depended on the conductivity of the solution. The prepared Au-Au BPE exhibited a remarkable amplification effect on the ECL signal. Then, a specific sensing interface was constructed on one pole of the BPE for the visual detection of prostate-specific antigens (PSA) based on sandwich-type immunoreactions between primary PSA antibodies (Ab1) on the electrode surface, PSA, and SiO2 nanoparticles labeled secondary PSA antibodies (SiO2-Ab2). The designed biosensor exhibited a good linear relationship for the ECL detection of PSA in the range of 1 × 10-6 to 1 × 10-10 g/mL with a correlation coefficient of 0.9866; the limit of detection (LOD) was 1.5 × 10-11 g/mL. Additionally, the biosensor can realize the electrochemical imaging of PSA by regulating the electrochemical oxidation of the Au anode with the immunoreactions on the cathode part of BPE. Therefore, the small, portable and highly sensitive biosensors have great potential for on-site detection.
Collapse
|
4
|
Abstract
The design and screening of electrocatalysts for gas evolution reactions suffer from little understanding of multiphase processes at the electrode-electrolyte interface. Due to the complexity of the multiphase interface, it is still a great challenge to capture gas evolution dynamics under operando conditions to precisely portray the intrinsic catalytic performance of the interface. Here, we establish a single particle imaging method to real-time monitor a potential-dependent vertical motion or hopping of electrocatalysts induced by electrogenerated gas nanobubbles. The hopping feature of a single particle is closely correlated with intrinsic activities of electrocatalysts and thus is developed as an indicator to evaluate gas evolution performance of various electrocatalysts. This optical indicator diminishes interference from heterogeneous morphologies, non-Faradaic processes, and parasitic side reactions that are unavoidable in conventional electrochemical measurements, therefore enabling precise evaluation and high-throughput screening of catalysts for gas evolution systems.
Collapse
|
5
|
Electrochemically Imaging the Response of Ion-Selective Membranes with an Ultralow Detection Limit. ACS APPLIED MATERIALS & INTERFACES 2022; 14:14097-14102. [PMID: 35298148 DOI: 10.1021/acsami.2c01839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The development of ion-selective membranes for the selective response of a particular ion has been studied for many years; however, imaging the response of the membrane with a low detection limit is challenging. Here, high spatial-resolution electrochemical imaging of this response down to picomolar is achieved using scanning ion conductive microscopy. The detection strategy relies on the exclusion of a small amount of counter ions from the membrane in the presence of a low concentration of target ions in the solution. These excluded counter ions are adsorbed at the membrane-solution interface, leading to more positive charges at the surface. The resultant elevation of the ionic current in the approach curve behaves as the response for the target ions down to 10-11 M, which is much more sensitive than that using potentiometric measurement. The constant-current scanning of the membrane exhibits the fluctuation of the apparent surface height that is correlated with the ionic concentration, permitting the imaging of the response at the nanoscale. The achievement of highly sensitive and spatial-resolution imaging for the ionic response enable the collection of spatial response at the ion-selective membrane, which will greatly advance the study of ion-selective electrodes.
Collapse
|
6
|
Abstract
Many fundamentally important biological phenomena involve the cells to establish and break down the adhesive interactions with the substrate. Here, we report a novel optical method that could directly image the electrochemical impedance of cell-substrate interactions at the single cell level with conventional microscopes and cameras. A thin conductive polymer layer on top of the ITO substrate (poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate), PEDOT:PSS) is used as the impedance imaging and sensing layer. A sinusoidal electrochemical potential is applied to the conductive polymer film, and the ion intercalation and transportation in the PEDOT:PSS layer will change the absorption spectrum of the polymer film. The attachment of the cells to the substrate will block and affect the ion doping and dedoping process, and therefore change the color of the polymer film. This process can be captured by any upright or inverted microscope with a simple camera. Utilizing this method, we have successfully imaged the impedance of single-cell attachment, observed the variations of cell-substrate interactions, and measured the impedance changes at different stages of the attachment process. This paper has proposed and successfully demonstrated a new strategy that translates the electrochemical impedance information to an optical signal that could be imaged and used to quantify the local responses. In addition, this method does not need any specially designed optical setup, which may lead to its broad applications in the clinics and biological research laboratories.
Collapse
|
7
|
Robust and High Spatial Resolution Light Addressable Electrochemistry Using Hematite (α-Fe 2O 3) Photoanodes. ACS APPLIED MATERIALS & INTERFACES 2018; 10:33662-33668. [PMID: 30230316 DOI: 10.1021/acsami.8b10812] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Light addressable/activated electrochemistry (LAE) has recently attracted attention as it can provide spatially resolved electrochemical information without using pre-patterned electrodes whose sizes and positions are unchangeable. Here, we propose hematite (α-Fe2O3) as the photoanode for LAE, which does not require any sort of surface modification for protection or facilitating charge transfer. As experimentally confirmed with various redox species, hematite is stable enough to be used for repetitive electroanalytical measurements. More importantly, it offers exceptionally high spatial resolution so that the "virtual electrode" is exactly as large as the light spot owing to the short diffusion length of the minority carriers. Quantitative analysis of dopamine in this study shows that the hematite-based photoanode is a promising platform for many potential LAE applications including spatially selective detection of oxidizable biomolecules.
Collapse
|
8
|
Simultaneous Topography and Reaction Flux Mapping at and around Electrocatalytic Nanoparticles. ACS NANO 2017; 11:9525-9535. [PMID: 28862831 DOI: 10.1021/acsnano.7b05435] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The characterization of electrocatalytic reactions at individual nanoparticles (NPs) is presently of considerable interest but very challenging. Herein, we demonstrate how simple-to-fabricate nanopipette probes with diameters of approximately 30 nm can be deployed in a scanning ion conductance microscopy (SICM) platform to simultaneously visualize electrochemical reactivity and topography with high spatial resolution at electrochemical interfaces. By employing a self-referencing hopping mode protocol, whereby the probe is brought from bulk solution to the near-surface at each pixel, and with potential-time control applied at the substrate, current measurements at the nanopipette can be made with high precision and resolution (30 nm resolution, 2600 pixels μm-2, <0.3 s pixel-1) to reveal a wealth of information on the substrate physicochemical properties. This methodology has been applied to image the electrocatalytic oxidation of borohydride at ensembles of AuNPs on a carbon fiber support in alkaline media, whereby the depletion of hydroxide ions and release of water during the reaction results in a detectable change in the ionic composition around the NPs. Through the use of finite element method simulations, these observations are validated and analyzed to reveal important information on heterogeneities in ion flux between the top of a NP and the gap at the NP-support contact, diffusional overlap and competition for reactant between neighboring NPs, and differences in NP activity. These studies highlight key issues that influence the behavior of NP assemblies at the single NP level and provide a platform for the use of SICM as an important tool for electrocatalysis studies.
Collapse
|
9
|
Electrochemical Motion Tracking of Microorganisms Using a Large-Scale-Integration-Based Amperometric Device. Angew Chem Int Ed Engl 2017; 56:6818-6822. [PMID: 28471045 DOI: 10.1002/anie.201701541] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2017] [Revised: 03/14/2017] [Indexed: 12/15/2022]
Abstract
Motion tracking of microorganisms is useful to investigate the effects of chemical or physical stimulation on their biological functions. Herein, we describe a novel electrochemical imaging method for motion tracking of microorganisms using a large-scale integration (LSI)-based amperometric device. The device consists of 400 electrochemical sensors with a pitch of 250 μm. A convection flow caused by the motion of microorganisms supplies redox species to the sensors and increases their electrochemical responses. Thus, the flow is converted to electrochemical signals, enabling the electrochemical motion tracking of the microorganisms. As a proof of concept, capillary vibration was monitored. Finally, the method was applied to monitoring the motion of Daphnia magna. The motions of these microorganisms were clearly tracked based on the electrochemical oxidation of [Fe(CN)6 ]4- and reduction of O2 .
Collapse
|
10
|
Biological imaging using light-addressable potentiometric sensors and scanning photo-induced impedance microscopy. Proc Math Phys Eng Sci 2017; 473:20170130. [PMID: 28588418 DOI: 10.1098/rspa.2017.0130] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2017] [Accepted: 04/07/2017] [Indexed: 11/12/2022] Open
Abstract
Light-addressable potentiometric sensors (LAPS) and scanning photo-induced impedance microscopy (SPIM) use photocurrent measurements at electrolyte-insulator-semiconductor substrates for spatio-temporal imaging of electrical potentials and impedance. The techniques have been used for the interrogation of sensor arrays and the imaging of biological systems. Sensor applications range from the detection of different types of ions and the label-free detection of charged molecules such as DNA and proteins to enzyme-based biosensors. Imaging applications include the temporal imaging of extracellular potentials and dynamic concentration changes in microfluidic channels and the lateral imaging of cell surface charges and cell metabolism. This paper will investigate the current state of the art of the measurement technology with a focus on spatial and temporal resolution and review the biological applications, these techniques have been used for. An outlook on future developments in the field will be given.
Collapse
|
11
|
Multifunctional scanning ion conductance microscopy. Proc Math Phys Eng Sci 2017; 473:20160889. [PMID: 28484332 PMCID: PMC5415692 DOI: 10.1098/rspa.2016.0889] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Accepted: 03/13/2017] [Indexed: 12/21/2022] Open
Abstract
Scanning ion conductance microscopy (SICM) is a nanopipette-based technique that has traditionally been used to image topography or to deliver species to an interface, particularly in a biological setting. This article highlights the recent blossoming of SICM into a technique with a much greater diversity of applications and capability that can be used either standalone, with advanced control (potential-time) functions, or in tandem with other methods. SICM can be used to elucidate functional information about interfaces, such as surface charge density or electrochemical activity (ion fluxes). Using a multi-barrel probe format, SICM-related techniques can be employed to deposit nanoscale three-dimensional structures and further functionality is realized when SICM is combined with scanning electrochemical microscopy (SECM), with simultaneous measurements from a single probe opening up considerable prospects for multifunctional imaging. SICM studies are greatly enhanced by finite-element method modelling for quantitative treatment of issues such as resolution, surface charge and (tip) geometry effects. SICM is particularly applicable to the study of living systems, notably single cells, although applications extend to materials characterization and to new methods of printing and nanofabrication. A more thorough understanding of the electrochemical principles and properties of SICM provides a foundation for significant applications of SICM in electrochemistry and interfacial science.
Collapse
|
12
|
Planar Diamond-Based Multiarrays to Monitor Neurotransmitter Release and Action Potential Firing: New Perspectives in Cellular Neuroscience. ACS Chem Neurosci 2017; 8:252-264. [PMID: 28027435 DOI: 10.1021/acschemneuro.6b00328] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
High biocompatibility, outstanding electrochemical responsiveness, inertness, and transparency make diamond-based multiarrays (DBMs) first-rate biosensors for in vitro detection of electrochemical and electrical signals from excitable cells together, with potential for in vivo applications as neural interfaces and prostheses. Here, we will review the electrochemical and physical properties of various DBMs and how these devices have been employed for recording released neurotransmitter molecules and all-or-none action potentials from living cells. Specifically, we will overview how DBMs can resolve localized exocytotic events from subcellular compartments using high-density microelectrode arrays (MEAs), or monitoring oxidizable neurotransmitter release from populations of cells in culture and tissue slices using low-density MEAs. Interfacing DBMs with excitable cells is currently leading to the promising opportunity of recording electrical signals as well as creating neuronal interfaces through the same device. Given the recent increasingly growing development of newly available DBMs of various geometries to monitor electrical activity and neurotransmitter release in a variety of excitable and neuronal tissues, the discussion will be limited to planar DBMs.
Collapse
|
13
|
Abstract
Nanopipettes are becoming extremely versatile and powerful tools in nanoscience for a wide variety of applications from imaging to nanoscale sensing. Herein, the capabilities of nanopipettes to build complex free-standing three-dimensional (3D) nanostructures are demonstrated using a simple double-barrel nanopipette device. Electrochemical control of ionic fluxes enables highly localized delivery of precursor species from one channel and simultaneous (dynamic and responsive) ion conductance probe-to-substrate distance feedback with the other for reliable high-quality patterning. Nanopipettes with 30-50 nm tip opening dimensions of each channel allowed confinement of ionic fluxes for the fabrication of high aspect ratio copper pillar, zigzag, and Γ-like structures, as well as permitted the subsequent topographical mapping of the patterned features with the same nanopipette probe as used for nanostructure engineering. This approach offers versatility and robustness for high-resolution 3D "printing" (writing) and read-out at the nanoscale.
Collapse
|
14
|
Abstract
The design, development, and application of high-speed scanning electrochemical probe microscopy is reported. The approach allows the acquisition of a series of high-resolution images (typically 1000 pixels μm(-2)) at rates approaching 4 seconds per frame, while collecting up to 8000 image pixels per second, about 1000 times faster than typical imaging speeds used up to now. The focus is on scanning electrochemical cell microscopy (SECCM), but the principles and practicalities are applicable to many electrochemical imaging methods. The versatility of the high-speed scan concept is demonstrated at a variety of substrates, including imaging the electroactivity of a patterned self-assembled monolayer on gold, visualization of chemical reactions occurring at single wall carbon nanotubes, and probing nanoscale electrocatalysts for water splitting. These studies provide movies of spatial variations of electrochemical fluxes as a function of potential and a platform for the further development of high speed scanning with other electrochemical imaging techniques.
Collapse
|
15
|
Nanocavity crossbar arrays for parallel electrochemical sensing on a chip. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2014; 5:1137-1143. [PMID: 25161846 PMCID: PMC4143123 DOI: 10.3762/bjnano.5.124] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/26/2014] [Accepted: 06/25/2014] [Indexed: 06/03/2023]
Abstract
We introduce a novel device for the mapping of redox-active compounds at high spatial resolution based on a crossbar electrode architecture. The sensor array is formed by two sets of 16 parallel band electrodes that are arranged perpendicular to each other on the wafer surface. At each intersection, the crossing bars are separated by a ca. 65 nm high nanocavity, which is stabilized by the surrounding passivation layer. During operation, perpendicular bar electrodes are biased to potentials above and below the redox potential of species under investigation, thus, enabling repeated subsequent reactions at the two electrodes. By this means, a redox cycling current is formed across the gap that can be measured externally. As the nanocavity devices feature a very high current amplification in redox cycling mode, individual sensing spots can be addressed in parallel, enabling high-throughput electrochemical imaging. This paper introduces the design of the device, discusses the fabrication process and demonstrates its capabilities in sequential and parallel data acquisition mode by using a hexacyanoferrate probe.
Collapse
|
16
|
Rapid structural change in synaptosomal-associated protein 25 (SNAP25) precedes the fusion of single vesicles with the plasma membrane in live chromaffin cells. Proc Natl Acad Sci U S A 2013; 110:14249-54. [PMID: 23940346 DOI: 10.1073/pnas.1306699110] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
The SNARE complex consists of the three proteins synaptobrevin-2, syntaxin, and synaptosomal-associated protein 25 (SNAP25) and is thought to execute a large conformational change as it drives membrane fusion and exocytosis. The relation between changes in the SNARE complex and fusion pore opening is, however, still unknown. We report here a direct measurement relating a change in the SNARE complex to vesicle fusion on the millisecond time scale. In individual chromaffin cells, we tracked conformational changes in SNAP25 by total internal reflection fluorescence resonance energy transfer (FRET) microscopy while exocytotic catecholamine release from single vesicles was simultaneously recorded using a microfabricated electrochemical detector array. A local rapid and transient FRET change occurred precisely where individual vesicles released catecholamine. To overcome the low time resolution of the imaging frames needed to collect sufficient signal intensity, a method named event correlation microscopy was developed, which revealed that the FRET change was abrupt and preceded the opening of an exocytotic fusion pore by ∼90 ms. The FRET change correlated temporally with the opening of the fusion pore and not with its dilation.
Collapse
|