1
|
Callary SA, Sharma DK, D’Apollonio TM, Campbell DG. Large articulations do not increase wear rates of thin second-generation highly cross-linked polyethylene liners at ten years. Bone Jt Open 2023; 4:839-845. [PMID: 37926113 PMCID: PMC10625862 DOI: 10.1302/2633-1462.411.bjo-2023-0124.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2023] Open
Abstract
Aims Radiostereometric analysis (RSA) is the most accurate radiological method to measure in vivo wear of highly cross-linked polyethylene (XLPE) acetabular components. We have previously reported very low wear rates for a sequentially irradiated and annealed X3 XLPE liner (Stryker Orthopaedics, USA) when used in conjunction with a 32 mm femoral heads at ten-year follow-up. Only two studies have reported the long-term wear rate of X3 liners used in conjunction with larger heads using plain radiographs which have poor sensitivity. The aim of this study was to measure the ten-year wear of thin X3 XLPE liners against larger 36 or 40 mm articulations with RSA. Methods We prospectively reviewed 19 patients who underwent primary cementless THA with the XLPE acetabular liner (X3) and a 36 or 40 mm femoral head with a resultant liner thickness of at least 5.8 mm. RSA radiographs at one week, six months, and one, two, five, and ten years postoperatively and femoral head penetration within the acetabular component were measured with UmRSA software. Of the initial 19 patients, 12 were available at the ten-year time point. Results The median proximal, 2D, and 3D wear rates calculated between one and ten years were all less than 0.005 mm/year, with no patient recording a proximal wear rate of more than 0.021 mm/year. Importantly, there was no increase in the wear rate between five and ten years. Conclusion The very low wear rate of X3 XLPE liners with larger articulations remains encouraging for the future clinical performance of this material.
Collapse
Affiliation(s)
- Stuart A. Callary
- Centre for Orthopaedic and Trauma Research, The University of Adelaide and Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia
| | - Deepti K. Sharma
- Centre for Orthopaedic and Trauma Research, The University of Adelaide and Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia
| | - Taisha M. D’Apollonio
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia
| | | |
Collapse
|
2
|
Hardwick-Morris M, Twiggs J, Miles B, Al-Dirini RMA, Taylor M, Balakumar J, Walter WL. Iliopsoas tendonitis after total hip arthroplasty : an improved detection method with applications to preoperative planning. Bone Jt Open 2023; 4:3-12. [PMID: 36598093 PMCID: PMC9887341 DOI: 10.1302/2633-1462.41.bjo-2022-0147.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
AIMS Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation. METHODS This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months' follow-up. 3D models of each patient's prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model's sensitivity, specificity, and area under the curve (AUC). RESULTS Highly significant differences between the symptomatic and asymptomatic cohorts were observed for iliopsoas impingement. Logistic regression models determined that the impingement values significantly predicted the probability of groin pain. The simulation had a sensitivity of 74%, specificity of 100%, and an AUC of 0.86. CONCLUSION We developed a computational model that can quantify iliopsoas impingement and verified its accuracy in a case-controlled investigation. This tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis.Cite this article: Bone Jt Open 2023;4(1):3-12.
Collapse
Affiliation(s)
- Max Hardwick-Morris
- 360 Med Care, Sydney, Australia,Flinders University, Adelaide, Australia,Correspondence should be sent to Max Hardwick-Morris. E-mail:
| | | | | | | | | | | | - William L. Walter
- Institute of Bone and Joint Research, Kolling Institute, The University of Sydney, Sydney, Australia,Department of Orthopaedics and Traumatic Surgery, Royal North Shore Hospital, Sydney, Australia
| |
Collapse
|
3
|
Fransen BL, Bengoa FJ, Neufeld ME, Sheridan GA, Garbuz DS, Howard LC. Thin highly cross-linked polyethylene liners combined with large femoral heads in primary total hip arthroplasty show excellent survival and low wear rates at a mean follow-up of 12.8 years. Bone Joint J 2023; 105-B:29-34. [PMID: 36587249 DOI: 10.1302/0301-620x.105b1.bjj-2022-0812.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
AIMS Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years' follow-up. METHODS We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear. RESULTS Overall survival rate for all-cause revision was 94.5% (95% confidence interval (CI) 81.7% to 97.2%) at a mean follow-up of 12.8 years (10.9 to 18.7). Three patients were revised, none for liner wear, fracture, or dissociation. A total of 22 patients were included in the radiological analysis (mean follow-up 9.9 years (7.5 to 13.7)). Mean linear liner wear was 0.085 mm (95% CI -0.086 to 0.257) and the volumetric wear rate was 11.097 mm3/year (95% CI -6.5 to 28.7). CONCLUSION Using HXLPE liners with 36 mm heads in 52 mm acetabular components or smaller is safe, with excellent survival and low rates of linear and volumetric wear at medium-term follow-up. Patients did not require revision surgery for liner complications such as fracture, dissociation, or wear. Our results suggest that the advantages of using larger heads outweigh the potential risks of using thin HXLPE liners.Cite this article: Bone Joint J 2023;105-B(1):29-34.
Collapse
Affiliation(s)
- Bas L Fransen
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Francisco J Bengoa
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Michael E Neufeld
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Gerard A Sheridan
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Donald S Garbuz
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| | - Lisa C Howard
- Department of Orthopaedics, The University of British Columbia, Vancouver, Canada
| |
Collapse
|
4
|
Gómez-Barrena E, Padilla-Eguiluz NG, López-Marfil M, Ruiz de la Reina R. Volume and location of bone regeneration after autologous expanded mesenchymal stromal cells in hip osteonecrosis : a pilot study. Bone Joint Res 2022; 11:881-889. [PMID: 36464628 PMCID: PMC9792875 DOI: 10.1302/2046-3758.1112.bjr-2022-0152.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
AIMS Successful cell therapy in hip osteonecrosis (ON) may help to avoid ON progression or total hip arthroplasty (THA), but the achieved bone regeneration is unclear. The aim of this study was to evaluate amount and location of bone regeneration obtained after surgical injection of expanded autologous mesenchymal stromal cells from the bone marrow (BM-hMSCs). METHODS A total of 20 patients with small and medium-size symptomatic stage II femoral head ON treated with 140 million BM-hMSCs through percutaneous forage in the EudraCT 2012-002010-39 clinical trial were retrospectively evaluated through preoperative and postoperative (three and 12 months) MRI. Then, 3D reconstruction of the original lesion and the observed postoperative residual damage after bone regeneration were analyzed and compared per group based on treatment efficacy. RESULTS The mean preoperative lesion volume was 18.7% (SD 10.2%) of the femoral head. This reduced to 11.6% (SD 7.5%) after three months (p = 0.015) and 3.7% (SD 3%) after one year (p < 0.001). Bone regeneration in healed cases represented a mean 81.2% (SD 13.8%) of the initial lesion volume at one year. Non-healed cases (n = 1 stage progression; n = 3 THAs) still showed bone regeneration but this did not effectively decrease the ON volume. A lesion size under mean 10% (SD 6%) of the femoral head at three months predicted no ON stage progression at one year. Regeneration in the lateral femoral head (C2 under Japanese Investigation Committee (JCI) classification) and in the central and posterior regions of the head was predominant in cases without ON progression. CONCLUSION Bone regeneration was observed in osteonecrotic femoral heads three months after expanded autologous BM-hMSC injection, and the volume and location of regeneration indicated the success of the therapy.Cite this article: Bone Joint Res 2022;11(12):881-889.
Collapse
Affiliation(s)
- Enrique Gómez-Barrena
- Department of Orthopedic Surgery and Traumatology, La Paz Hospital, IdiPaz, Universidad Autónoma de Madrid, Madrid, Spain, Enrique Gómez-Barrena. E-mail:
| | - Norma-Griset Padilla-Eguiluz
- Department of Orthopedic Surgery and Traumatology, La Paz Hospital, IdiPaz, Universidad Autónoma de Madrid, Madrid, Spain
| | - Marta López-Marfil
- Biomedical Engineering Master program, Universidad Politécnica de Madrid, Madrid, Spain
| | | | | |
Collapse
|
5
|
García-Rey E, Cruz-Pardos A, Saldaña L. New polyethylenes in total hip arthroplasty : a 20- to 22-year follow-up study. Bone Joint J 2022; 104-B:1032-1038. [PMID: 36047028 DOI: 10.1302/0301-620x.104b9.bjj-2022-0434.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS A significant reduction in wear at five and ten years was previously reported when comparing Durasul highly cross-linked polyethylene with nitrogen-sterilized Sulene polyethylene in total hip arthroplasty (THA). We investigated whether the improvement observed at the earlier follow-up continued, resulting in decreased osteolysis and revision surgery rates over the second decade. METHODS Between January 1999 and December 2001, 90 patients underwent surgery using the same acetabular and femoral components with a 28 mm metallic femoral head and either a Durasul or Sulene liner. A total of 66 hips of this prospective randomized study were available for a minimum follow-up of 20 years. The linear femoral head penetration rate was measured at six weeks, one year, and annually thereafter, using the Dorr method on digitized radiographs with a software package. RESULTS In the Durasul group, no patients underwent revision due to loosening or showed radiological evidence of osteolysis. In the Sulene group, four patients (four hips) were revised due to femoral component loosening. The 20-year cumulative failure incidence in the presence of the competing event of death for revision surgery was 4.5% (95% confidence interval (CI) 0.8 to 13.6) in the Durasul group, and 8.9% (95% CI 2.8 to 19.5) in the Sulene group. The mean wear one year after surgery was 0.09 mm (SD 0.007) in the Durasul group and 0.24 (SD 0.015) in the Sulene group (p < 0.001). From one to 20 years after surgery, the mean total penetration was 0.32 mm (SD 0.045) in the Durasul group and 1.07 mm (SD 0.13) in the Sulene group (p < 0.001). Mean femoral head penetration at 20 years was approximately 70.0% less in the Durasul group than the Sulene group. CONCLUSION The significant reduction in femoral head penetration obtained with the Durasul compared with Sulene in uncemented THA resulted in lower osteolysis and revision rates after 20 years.Cite this article: Bone Joint J 2022;104-B(9):1032-1038.
Collapse
Affiliation(s)
- Eduardo García-Rey
- Orthopaedics Department, Hospital Universitario La Paz-Idi Paz, Madrid, Spain.,Bioengineering, Biomaterials and Nanomedicine, Biomedical Research Networking Center, Madrid, Spain
| | - Ana Cruz-Pardos
- Orthopaedics Department, Hospital Universitario La Paz-Idi Paz, Madrid, Spain
| | - Laura Saldaña
- Bioengineering, Biomaterials and Nanomedicine, Biomedical Research Networking Center, Madrid, Spain.,Bone Pathophysiology and Biomaterials Group, Hospital Universitario La Paz-Idi Paz, Madrid, Spain
| |
Collapse
|
6
|
Grothe T, Günther KP, Hartmann A, Blum S, Haselhoff R, Goronzy J. The incidence of adverse local tissue reaction due to head taper corrosion after total hip arthroplasty using V40 taper and 36 mm CoCr head. Bone Joint J 2022; 104-B:852-858. [PMID: 35775169 DOI: 10.1302/0301-620x.104b7.bjj-2021-1769.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Head-taper corrosion is a cause of failure in total hip arthroplasty (THA). Recent reports have described an increasing number of V40 taper failures with adverse local tissue reaction (ALTR). However, the real incidence of V40 taper damage and its cause remain unknown. The aim of this study was to evaluate the long-term incidence of ALTR in a consecutive series of THAs using a V40 taper and identify potentially related factors. METHODS Between January 2006 and June 2007, a total of 121 patients underwent THA using either an uncemented (Accolade I, made of Ti12Mo6Zr2Fe; Stryker, USA) or a cemented (ABG II, made of cobalt-chrome-molybdenum (CoCrMo); Stryker) femoral component, both with a V40 taper (Stryker). Uncemented acetabular components (Trident; Stryker) with crosslinked polyethylene liners and CoCr femoral heads of 36 mm diameter were used in all patients. At a mean folllow-up of 10.8 years (SD 1.1), 94 patients (79%) were eligible for follow-up (six patients had already undergone a revision, 15 had died, and six were lost to follow-up). A total of 85 THAs in 80 patients (mean age 61 years (24 to 75); 47 (56%) were female) underwent clinical and radiological evaluation, including the measurement of whole blood levels of cobalt and chrome. Metal artifact reduction sequence MRI scans of the hip were performed in 71 patients. RESULTS A total of 20 ALTRs were identified on MRI, with an incidence of 26%. Patients with ALTR had significantly higher median Co levels compared with those without ALTR (2.96 μg/l (interquartile range (IQR) 1.35 to 4.98) vs 1.44 μg/l (IQR 0.79 to 2.5); p = 0.019). Radiological evidence of osteolysis was also significantly associated with ALTR (p = 0.014). Median Cr levels were not significantly higher in those with ALTR compared with those without one (0.97 μg/l (IQR 0.72 to 1.9) v 0.67 μg/l (IQR 0.5 to 1.19; p = 0.080). BMI, sex, age, type of femoral component, head length, the inclination of the acetabular component, and heterotopic ossification formation showed no significant relationship with ALTR. CONCLUSION Due to the high incidence of local ALTR in our cohort after more than ten years postoperatively, we recommend regular follow-up investigation even in asymptomatic patients with V40 taper and metal heads. As cobalt levels correlate with ALTR occurrence, routine metal ion screening and consecutive MRI investigation upon elevation could be discussed. Cite this article: Bone Joint J 2022;104-B(7):852-858.
Collapse
Affiliation(s)
- Tim Grothe
- Centre of Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Technical University Dresden, Dresden, Germany
| | - Klaus-Peter Günther
- Centre of Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Technical University Dresden, Dresden, Germany
| | - Albrecht Hartmann
- Centre of Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Technical University Dresden, Dresden, Germany
| | - Sophia Blum
- Department of Radiology, University Hospital Carl Gustav Carus, Technical University Dresden, Dresden, Germany
| | - Richard Haselhoff
- Centre of Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Technical University Dresden, Dresden, Germany
| | - Jens Goronzy
- Centre of Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Technical University Dresden, Dresden, Germany
| |
Collapse
|
7
|
Kayani B, Baawa-Ameyaw J, Fontalis A, Tahmassebi J, Wardle N, Middleton R, Stephen A, Hutchinson J, Haddad FS. Oxidized zirconium versus cobalt-chrome femoral heads in total hip arthroplasty: a multicentre prospective randomized controlled trial with ten years' follow-up. Bone Joint J 2022; 104-B:833-843. [PMID: 35775177 DOI: 10.1302/0301-620x.104b7.bjj-2021-1673.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS This study reports the ten-year wear rates, incidence of osteolysis, clinical outcomes, and complications of a multicentre randomized controlled trial comparing oxidized zirconium (OxZr) versus cobalt-chrome (CoCr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) and highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA). METHODS Patients undergoing primary THA were recruited from four institutions and prospectively allocated to the following treatment groups: Group A, CoCr femoral head with XLPE liner; Group B, OxZr femoral head with XLPE liner; and Group C, OxZr femoral head with UHMWPE liner. All study patients and assessors recording outcomes were blinded to the treatment groups. The outcomes of 262 study patients were analyzed at ten years' follow-up. RESULTS Patients in Group C were associated with increased mean liner wear rates compared to patients in Group A (0.133 mm/yr (SD 0.21) vs 0.031 mm/yr (SD 0.07), respectively; p < 0.001) and Group B (0.133 mm/yr (SD 0.21) vs 0.022 mm/yr (SD 0.05), respectively; p < 0.001) at ten years' follow-up. Patients in Group C were also associated with increased risk of osteolysis and aseptic loosening requiring revision surgery, compared with patients in Group A (7/133 vs 0/133, respectively; p = 0.007) and Group B (7/133 vs 0/135, respectively; p = 0.007). There was a non-statistically significant trend towards increased mean liner wear rates in Group A compared with Group B (0.031 mm/yr (SD 0.07) vs 0.022 mm/yr (SD 0.05), respectively; p = 0.128). All three groups were statistically comparable preoperatively and at ten years' follow-up when measuring normalized Western Ontario and McMaster Universities Osteoarthritis Index (p = 0.410), 36-Item Short Form Health Survey (p = 0.465 mental, p = 0.713 physical), and pain scale scores (p = 0.451). CONCLUSION The use of UHMWPE was associated with progressively increased annual liner wear rates after THA compared to XLPE. At ten years' follow-up, the group receiving UHMWPE demonstrated an increased incidence of osteolysis and aseptic loosening requiring revision surgery compared to XLPE. Femoral heads composed of OxZr were associated with trend towards reduced wear rates compared to CoCr, but this did not reach statistical significance and did not translate to any differences in osteolysis, functional outcomes, or revision surgery between the two femoral head components. Cite this article: Bone Joint J 2022;104-B(7):833-843.
Collapse
Affiliation(s)
- Babar Kayani
- Department of Trauma and Orthopaedics, University College Hospital, London, UK
| | - Joanna Baawa-Ameyaw
- Department of Trauma and Orthopaedics, University College Hospital, London, UK
| | - Andreas Fontalis
- Department of Trauma and Orthopaedics, University College Hospital, London, UK
| | - Jenni Tahmassebi
- Department of Trauma and Orthopaedics, University College Hospital, London, UK
| | - Nick Wardle
- Colchester Hospital University Foundation Trust, Colchester, UK
| | - Robert Middleton
- Department of Trauma and Orthopaedics, Bournemouth University, Bournemouth, UK
| | | | | | - Fares S Haddad
- Department of Trauma and Orthopaedics, University College Hospital, London, UK
| |
Collapse
|
8
|
Deere K, Matharu GS, Ben-Shlomo Y, Wilkinson JM, Blom AW, Sayers A, Whitehouse MR. The risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders with cobalt-chrome-containing total hip arthroplasty implants : an analysis of the National Joint Registry. Bone Joint J 2022; 104-B:359-367. [PMID: 35227088 DOI: 10.1302/0301-620x.104b3.bjj-2021-0397.r1] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
AIMS A recent report from France suggested an association between the use of cobalt-chrome (CoCr) femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. CoCr is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint arthroplasties and other orthopaedic procedures in which CoCr is used annually. We examined whether CoCr-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database. METHODS Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years' follow-up. We excluded any patients with bilateral THAs, knee arthroplasties, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing CoCr or not containing CoCr. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined. RESULTS There were 158,677 individuals (42.4%) with an implant containing CoCr. There were 47,963 deaths, 27,332 heart outcomes, 35,720 cancers, and 22,025 neurodegenerative disorders. There was no evidence of an association between patients with CoCr implants and higher rates of any of the outcomes. CONCLUSION CoCr-containing THAs did not have an increased risk of all-cause mortality, or clinically meaningful heart outcomes, cancer, or neurodegenerative disorders into the second decade post-implantation. Our findings will help reassure clinicians and the increasing number of patients receiving primary THA worldwide that the use of CoCr-containing implants is not associated with significant adverse systemic effects. Cite this article: Bone Joint J 2022;104-B(3):359-367.
Collapse
Affiliation(s)
- Kevin Deere
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Gulraj S Matharu
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Yoav Ben-Shlomo
- Department of Population Health Sciences, University of Bristol, Bristol, UK
| | - J Mark Wilkinson
- Department of Oncology and Metabolism, University of Sheffield, Sheffield, UK
| | - Ashley W Blom
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK.,National Institute for Health Research Bristol Biomedical Research Centre, University of Bristol, Bristol, UK
| | - Adrian Sayers
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Michael R Whitehouse
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK.,National Institute for Health Research Bristol Biomedical Research Centre, University of Bristol, Bristol, UK
| |
Collapse
|
9
|
Jung CH, Cha Y, Yoon HS, Park CH, Yoo JI, Kim JT, Jeon Y. Mechanical effects of surgical variations in the femoral neck system on Pauwels type III femoral neck fracture : a finite element analysis. Bone Joint Res 2022; 11:102-111. [PMID: 35168366 PMCID: PMC8882323 DOI: 10.1302/2046-3758.112.bjr-2021-0282.r1] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
AIMS In this study, we aimed to explore surgical variations in the Femoral Neck System (FNS) used for stable fixation of Pauwels type III femoral neck fractures. METHODS Finite element models were established with surgical variations in the distance between the implant tip and subchondral bone, the gap between the plate and lateral femoral cortex, and inferior implant positioning. The models were subjected to physiological load. RESULTS Under a load of single-leg stance, Pauwels type III femoral neck fractures fixed with 10 mm shorter bolts revealed a 7% increase of the interfragmentary gap. The interfragmentary sliding, compressive, and shear stress remained similar to models with bolt tips positioned close to the subchondral bone. Inferior positioning of FNS provided a similar interfragmentary distance, but with 6% increase of the interfragmentary sliding distance compared to central positioning of bolts. Inferior positioning resulted in a one-third increase in interfragmentary compressive and shear stress. A 5 mm gap placed between the diaphysis and plate provided stability comparable to standard fixation, with a 7% decrease of interfragmentary gap and sliding distance, but similar compressive and shear stress. CONCLUSION Finite element analysis with FNS on Pauwels type III femoral neck fractures revealed that placement of the bolt tip close to subchondral bone provides increased stability. Inferior positioning of FNS bolt increased interfragmentary sliding distance, compressive, and shear stress. The comparable stability of the fixation model with the standard model suggests that a 5 mm gap placed between the plate and diaphysis could viably adjust the depth of the bolt. Cite this article: Bone Joint Res 2022;11(2):102-111.
Collapse
Affiliation(s)
- Chang-Ho Jung
- Department of Mechanical Engineering, Ajou University, Suwon, South Korea
| | - Yonghan Cha
- Department of Orthopaedic Surgery, Eulji University Hospital, Daejeon, South Korea
| | - Ha Seung Yoon
- Department of Orthopaedic Surgery, Ajou University School of Medicine, Ajou Medical Center, Suwon, South Korea
| | - Chan Ho Park
- Department of Orthopaedic Surgery, Yeungnam University Medical Center, Daegu, South Korea
| | - Jun-Il Yoo
- Department of Orthopaedic Surgery, Gyeongsang National University Hospital, Jinju, South Korea
| | - Jung-Taek Kim
- Department of Orthopaedic Surgery, Ajou University School of Medicine, Ajou Medical Center, Suwon, South Korea
| | - Yongho Jeon
- Department of Mechanical Engineering, Ajou University, Suwon, South Korea
| |
Collapse
|
10
|
Gani MH, Zahoor U, Hanna SA, Scott G. Metal-on-metal hip resurfacing arthroplasty provides excellent long-term survivorship and function in patients with a good-sized femoral head : results of a single, non-designer surgeon's cohort. Bone Jt Open 2022; 3:68-76. [PMID: 35045731 PMCID: PMC9047081 DOI: 10.1302/2633-1462.31.bjo-2021-0135.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Aims To establish the survivorship, function, and metal ion levels in an unselected series of metal-on-metal hip resurfacing arthroplasties (HRAs) performed by a non-designer surgeon. Methods We reviewed 105 consecutive HRAs in 83 patients, performed by a single surgeon, at a mean follow-up of 14.9 years (9.3 to 19.1). The cohort included 45 male and 38 female patients, with a mean age of 49.5 years (SD 12.5) Results At the time of review 13 patients with 15 hips had died from causes unrelated to the hip operation, and 14 hips had undergone revision surgery, giving an overall survival rate of rate of 86.7% (95% confidence interval (CI) 84.2 to 89.1). The survival rate in men was 97.7% (95% CI 96.3 to 98.9) and in women was 73.4% (95% CI 70.6 to 75.1). The median head size of the failed group was 42 mm (interquartile range (IQR) 42 to 44), and in the surviving group was 50 mm (IQR 46 to 50). In all, 13 of the 14 revised hips had a femoral component measuring ≤ 46 mm. The mean blood levels of cobalt and chromium ions were 26.6 nmol/l (SD 24.5) and 30.6 nmol/l (SD 15.3), respectively. No metal ion levels exceeded the safe limit. The mean Oxford Hip Score was 41.5 (SD 8.9) and Harris Hip Score was 89.9 (14.8). In the surviving group, four patients had radiolucent lines around the stem of the femoral component, and one had lysis around the acetabular component; eight hips demonstrated heterotopic ossification. Conclusion Our results confirm the existing understanding that HRA provides good long-term survival and function in patients with adequate-sized femoral heads. This is evidenced by a 97.7% survival rate among men (larger heads) in our series at a mean follow-up of 14.9 years. Failure is closely related to head sizes ≤ 46 cm. Cite this article: Bone Jt Open 2022;3(1):68–76.
Collapse
Affiliation(s)
- M Haseeb Gani
- Department of Orthopaedics, The Royal London Hospital, London, UK
| | - Ubaid Zahoor
- Department of Orthopaedics, The Royal London Hospital, London, UK
| | - Sammy A Hanna
- Department of Orthopaedics, The Royal London Hospital, London, UK
| | - Gareth Scott
- Department of Orthopaedics, The Royal London Hospital, London, UK.,Barts and the London School of Medicine and Dentistry, London, UK
| |
Collapse
|
11
|
Affiliation(s)
- Maoxiao Ma
- Hunan University of Chinese Medicine, Changsha, China.,Orthopedic Department, Luoyang Orthopedic Hospital of Henan Province, Luoyang, China
| | - Zhen Tan
- Department of Bone and Joint Surgery, Peking University Shenzhen Hospital, Shenzhen, China
| | - Wuyin Li
- Orthopedic Department, Luoyang Orthopedic Hospital of Henan Province, Luoyang, China
| | - Hong Zhang
- Orthopedic Department, Luoyang Orthopedic Hospital of Henan Province, Luoyang, China
| | - Youwen Liu
- Orthopedic Department, Luoyang Orthopedic Hospital of Henan Province, Luoyang, China
| | - Chen Yue
- Orthopedic Department, Luoyang Orthopedic Hospital of Henan Province, Luoyang, China.,Zhejiang Chinese Medical University, Hangzhou, China
| |
Collapse
|
12
|
Cnudde PHJ, Nåtman J, Hailer NP, Rogmark C. Total, hemi, or dual-mobility arthroplasty for the treatment of femoral neck fractures in patients with neurological disease : analysis of 9,638 patients from the Swedish Hip Arthroplasty Register. Bone Joint J 2022; 104-B:134-141. [PMID: 34969279 DOI: 10.1302/0301-620x.104b1.bjj-2021-0855.r1] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
AIMS The aim of this study was to investigate the potentially increased risk of dislocation in patients with neurological disease who sustain a femoral neck fracture, as it is unclear whether they should undergo total hip arthroplasty (THA) or hemiarthroplasty (HA). A secondary aim was to investgate whether dual-mobility components confer a reduced risk of dislocation in these patients. METHODS We undertook a longitudinal cohort study linking the Swedish Hip Arthroplasty Register with the National Patient Register, including patients with a neurological disease presenting with a femoral neck fracture and treated with HA, a conventional THA (cTHA) with femoral head size of ≤ 32 mm, or a dual-mobility component THA (DMC-THA) between 2005 and 2014. The dislocation rate at one- and three-year revision, reoperation, and mortality rates were recorded. Cox multivariate regression models were fitted to calculate adjusted hazard ratios (HRs). RESULTS A total of 9,638 patients with a neurological disease who also underwent unilateral arthroplasty for a femoral neck fracture were included in the study. The one-year dislocation rate was 3.7% after HA, 8.8% after cTHA < 32 mm), 5.9% after cTHA (= 32 mm), and 2.7% after DMC-THA. A higher risk of dislocation was associated with cTHA (< 32 mm) compared with HA (HR 1.90 (95% confidence interval (CI) 1.26 to 2.86); p = 0.002). There was no difference in the risk of dislocation with DMC-THA (HR 0.68 (95% CI 0.26 to 1.84); p = 0.451) or cTHA (= 32 mm) (HR 1.54 (95% CI 0.94 to 2.51); p = 0.083). There were no differences in the rate of reoperation and revision-free survival between the different types of prosthesis and sizes of femoral head. CONCLUSION Patients with a neurological disease who sustain a femoral neck fracture have similar rates of dislocation after undergoing HA or DMC-THA. Most patients with a neurological disease are not eligible for THA and should thus undergo HA, whereas those eligible for THA could benefit from a DMC-THA. Cite this article: Bone Joint J 2022;104-B(1):134-141.
Collapse
Affiliation(s)
- Peter H J Cnudde
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden.,Department of Orthopaedics, Goteborgs Universitet Sahlgrenska Akademin, Goteborg, Sweden.,Department of Orthopaedics, Hywel Dda University Health Board, Llanelli, UK
| | | | - Nils P Hailer
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden.,Department of Orthopaedics, Institute of Surgical Sciences, Uppsala University Hospital, Uppsala, Sweden
| | - Cecilia Rogmark
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden.,Department of Orthopaedics, Lund University Faculty of Medicine, Malmö, Sweden
| |
Collapse
|
13
|
Abstract
Dislocation following total hip arthroplasty (THA) is a well-known and potentially devastating complication. Clinicians have used many strategies in attempts to prevent dislocation since the introduction of THA. While the importance of postoperative care cannot be ignored, particular emphasis has been placed on preoperative planning in the prevention of dislocation. The strategies have progressed from more traditional approaches, including modular implants, the size of the femoral head, and augmentation of the offset, to newer concepts, including patient-specific component positioning combined with computer navigation, robotics, and the use of dual-mobility implants. As clinicians continue to pursue improved outcomes and reduced complications, these concepts will lay the foundation for future innovation in THA and ultimately improved outcomes. Cite this article: Bone Joint J 2022;104-B(1):8-11.
Collapse
Affiliation(s)
- Joshua Wright-Chisem
- Hospital for Special Surgery, Division of Adult Reconstruction and Joint Replacement, New York, New York, USA
| | - Ameer M Elbuluk
- Hospital for Special Surgery, Division of Adult Reconstruction and Joint Replacement, New York, New York, USA
| | - David J Mayman
- Hospital for Special Surgery, Division of Adult Reconstruction and Joint Replacement, New York, New York, USA
| | - Seth A Jerabek
- Hospital for Special Surgery, Division of Adult Reconstruction and Joint Replacement, New York, New York, USA
| | - Peter K Sculco
- Hospital for Special Surgery, Division of Adult Reconstruction and Joint Replacement, New York, New York, USA
| | - Jonathan M Vigdorchik
- Hospital for Special Surgery, Division of Adult Reconstruction and Joint Replacement, New York, New York, USA
| |
Collapse
|
14
|
Huhnstock S, Wiig O, Merckoll E, Svenningsen S, Terjesen T. The modified Stulberg classification is a strong predictor of the radiological outcome 20 years after the diagnosis of Perthes' disease. Bone Joint J 2021; 103-B:1815-1820. [PMID: 34847712 DOI: 10.1302/0301-620x.103b12.bjj-2021-0515.r1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The aim of this study was to assess the prognostic value of the modified three-group Stulberg classification, which is based on the sphericity of the femoral head, in patients with Perthes' disease. METHODS A total of 88 patients were followed from the time of diagnosis until a mean follow-up of 21 years. Anteroposterior pelvic and frog-leg lateral radiographs were obtained at diagnosis and at follow-up of one, five, and 21 years. At the five- and 21-year follow-up, the femoral heads were classified using a modified three-group Stulberg classification (round, ovoid, or flat femoral head). Further radiological endpoints at long-term follow-up were osteoarthritis (OA) of the hip and the requirement for total hip arthroplasty (THA). RESULTS There were 71 males (81%) and 17 females. A total of 13 patients had bilateral Perthes' disease; thus 101 hips were analyzed. At five-year follow-up, 37 hips were round, 38 ovoid, and 26 flat. At that time, 66 hips (65%) were healed and 91 (90%) were skeletally immature. At long-term follow-up, when the mean age of the patients was 28 years (24 to 34), 20 hips had an unsatisfactory outcome (seven had OA and 13 had required THA). There was a strongly significant association between the modified Stulberg classification applied atfive-year follow-up and an unsatisfactory outcome at long-term follow-up (p < 0.001). Between the five- and 21-year follow-up, 67 hips (76%) stayed in their respective modified Stulberg group, indicating a strongly significant association between the Stulberg classifications at these follow-ups (p < 0.001). CONCLUSION The modified Stulberg classification is a strong predictor of long-term radiological outcome in patients with Perthes' disease. It can be applied at the healing stage, which is usually reached five years after the diagnosis is made and before skeletal maturity. Cite this article: Bone Joint J 2021;103-B(12):1815-1820.
Collapse
Affiliation(s)
- Stefan Huhnstock
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway
| | - Ola Wiig
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway
| | - Else Merckoll
- Department of Radiology, Oslo University Hospital, Oslo, Norway
| | | | - Terje Terjesen
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway.,Faculty of Medicine, University of Oslo, Oslo, Norway
| |
Collapse
|
15
|
Bhanushali A, Chimutengwende-Gordon M, Beck M, Callary SA, Costi K, Howie DW, Solomon LB. The variation in hip stability measurements between supine and standing radiographs of dysplastic hips. Bone Joint J 2021; 103-B:1662-1668. [PMID: 34719274 DOI: 10.1302/0301-620x.103b11.bjj-2020-2519.r2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The aims of this study were to compare clinically relevant measurements of hip dysplasia on radiographs taken in the supine and standing position, and to compare Hip2Norm software and Picture Archiving and Communication System (PACS)-derived digital radiological measurements. METHODS Preoperative supine and standing radiographs of 36 consecutive patients (43 hips) who underwent periacetabular osteotomy surgery were retrospectively analyzed from a single-centre, two-surgeon cohort. Anterior coverage (AC), posterior coverage (PC), lateral centre-edge angle (LCEA), acetabular inclination (AI), sharp angle (SA), pelvic tilt (PT), retroversion index (RI), femoroepiphyseal acetabular roof (FEAR) index, femoroepiphyseal horizontal angle (FEHA), leg length discrepancy (LLD), and pelvic obliquity (PO) were analyzed using both Hip2Norm software and PACS-derived measurements where applicable. RESULTS Analysis of supine and standing radiographs resulted in significant variation for measurements of PT (p < 0.001) and AC (p = 0.005). The variation in PT correlated with the variation in AC in a limited number of patients (R2 = 0.378; p = 0.012). CONCLUSION The significant variation in PT and AC between supine and standing radiographs suggests that it may benefit surgeons to have both radiographs when planning surgical correction of hip dysplasia. We also recommend using PACS-derived measurements of AI and SA due to the poor interobserver error on Hip2Norm. Cite this article: Bone Joint J 2021;103-B(11):1662-1668.
Collapse
Affiliation(s)
- Ameya Bhanushali
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | | | - Martin Beck
- Department of Orthopaedics and Trauma, Orthopaedic Clinic Lucerne AG, Lucerne, Switzerland
| | - Stuart Adam Callary
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia.,Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, Australia
| | - Kerry Costi
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Donald W Howie
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia.,Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, Australia
| | - Lucian Bogdan Solomon
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia.,Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, Australia
| |
Collapse
|
16
|
van Gammeren AJ, van Rijckevorsel M, Bras AE, Brandt-Hagens C, Te Marvelde JG, de Visser C, Joosen AMCP, Ermens AAM, van der Velden VHJ. Usability of femoral head bone marrow to verify reference ranges for the assessment of myelodysplasia by flow cytometry. Int J Lab Hematol 2018; 40:726-733. [PMID: 30173422 DOI: 10.1111/ijlh.12911] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Revised: 03/30/2018] [Accepted: 07/10/2018] [Indexed: 01/24/2023]
Abstract
BACKGROUND A flow cytometry score (FCS) based on four parameters has been proposed for analysis of myelodysplastic syndromes patients with <5% blasts. We evaluated whether bone marrow aspirate samples isolated from femoral heads could be used for verification of cutoff values of the individual parameters score (IPS), contributing to the FCS and compared the applicability of FCS parameters in two centers. STUDY DESIGN AND METHODS Bone marrow cells were obtained from femoral heads of patients who underwent hip replacement surgery. The score of the 4 individual parameters of the cell samples were obtained independently in two centers, using their own facilities and methods. Flow cytometry data files were subsequently exchanged and reanalyzed in the other center. The resulting four data sets were compared to assess reproducibility and outcomes in both centers. RESULTS Twenty-nine of 40 bone marrow samples contained sufficient cells for analysis. Proposed cutoff values for 3 of 4 individual parameters were appropriate. All 29 samples showed a positive individual parameters score (IPS:1) in 1 of the 4 obtained data sets. Most differences in IPS scores were a result of reanalyzing the data file in the other center, rather than data acquisition. FCS: ≥2 were observed in 11 samples. CONCLUSION Bone marrow samples from femoral heads are appropriate for verification of the proposed reference cutoff values of the individual parameters. Proposed reference cutoff values needed to be adjusted for reliable interpretation. Standardization of both data acquisition and data analysis is necessary for obtaining uniform results.
Collapse
Affiliation(s)
- Adriaan J van Gammeren
- Department of Clinical Chemistry and Hematology, Amphia Hospital, Breda, the Netherlands
| | - M van Rijckevorsel
- Department of Clinical Chemistry and Hematology, Amphia Hospital, Breda, the Netherlands
| | - Anne E Bras
- Department of Immunology, Laboratory Medical Immunology, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, the Netherlands
| | - Claudia Brandt-Hagens
- Department of Immunology, Laboratory Medical Immunology, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, the Netherlands
| | - Jeroen G Te Marvelde
- Department of Immunology, Laboratory Medical Immunology, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, the Netherlands
| | - Carin de Visser
- Department of Clinical Chemistry and Hematology, Amphia Hospital, Breda, the Netherlands
| | - Annemiek M C P Joosen
- Department of Clinical Chemistry and Hematology, Amphia Hospital, Breda, the Netherlands
| | - Anton A M Ermens
- Department of Clinical Chemistry and Hematology, Amphia Hospital, Breda, the Netherlands
| | - Vincent H J van der Velden
- Department of Immunology, Laboratory Medical Immunology, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, the Netherlands
| |
Collapse
|
17
|
Taddei P, Pavoni E, Affatato S. Raman and Photoemission Spectroscopic Analyses of Explanted Biolox ® Delta Femoral Heads Showing Metal Transfer. Materials (Basel) 2017; 10:E744. [PMID: 28773102 DOI: 10.3390/ma10070744] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2017] [Revised: 06/25/2017] [Accepted: 06/29/2017] [Indexed: 11/17/2022]
Abstract
Biolox® delta has been widely used in joint replacements thanks to its high strength and wear resistance. In this study, eleven Biolox® delta femoral head retrievals affected by metal transfer (MT) were analysed by Raman spectroscopy to estimate the tetragonal to monoclinic zirconia phase transformation, whose occurrence may compromise ceramic chemical stability and mechanical strength. The residual stress state was evaluated by both Raman and photoemission spectroscopy. Vm monoclinic zirconia contents were higher near the centre of the articulating surface and in the MT area than in the border control area of the retrievals. In only one retrieval, stress related to MT appeared a more severe condition, able to induce zirconia phase transformation; for all the others, stresses related to loading in the central region and related to MT, were conducive to a zirconia phase transformation of nearly the same extent. Vm depth profiling analyses showed that the transformation involved different thicknesses in different samples. Raman data allowed for the investigation of the mechanism of zirconia phase transformation and confirmed that the growth stage was absent and the nucleation stage was not occurring as freely as it would in unconstrained zirconia.
Collapse
|