1
|
Tepe H, Irmak Ö. Clinical performance of non-carious cervical lesions restored with using self-etch mode of adhesives according to the FDI criteria. Aust Dent J 2023; 68:255-264. [PMID: 37665237 DOI: 10.1111/adj.12975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/16/2023] [Indexed: 09/05/2023]
Abstract
AIM The purpose of this study was to evaluate the 18-month retrospective study of self-etch adhesive (Prime&Bond One Select) and self-etch mode of universal adhesives (Single Bond Universal, Gluma Bond Universal) applied to non-carious cervical lesions according to the World Dental Federation criteria. MATERIALS AND METHODS Thirty patients without any systemic disease, good oral hygiene, having at least 20 teeth and six non-carious cervical lesions treated using a self-etch mode of adhesives operated between January and March 2017. Accordingly, 335 restorations were evaluated according to the World Dental Federation criteria at 3, 6, 12 and 18 months. Pillai's Trace test was used to determine the interaction of criteria with time and adhesive systems. IBM SPSS Statistics 21.0 program was used in the analysis. Value of P < 0.05 was accepted as a criterion for statistical significance. RESULTS At the end of 18 months, participation was 100%. There was a statistically significant difference P < 0.05 between Prime&Bond One Select and Single Bond Universal, Prime&Bond One Select and Gluma Bond Universal in the 18-month period. In terms of marginal staining, fracture of material and retention, recurrence of caries, erosion and abfraction, tooth integrity criteria at the end of the 18 months, Prime&Bond One Select performed clinically very good, Single Bond Universal and Gluma Bond Universal performed clinically good according to World Dental Federation criteria. Marginal adaptation criteria, Prime&Bond One Select, Single Bond Universal and Gluma Bond Universal performed clinically good. Retention loss rate was found to be the lowest in Prime&Bond One Select and the highest in Gluma Bond Universal. CONCLUSION Accordingly, 18-month evaluation of all adhesives used in the study showed clinically acceptable results in all of the World Dental Federation criteria.
Collapse
Affiliation(s)
- H Tepe
- Department of Restorative Dentistry, Faculty of Dentistry, Eskisehir Osmangazi University, Eskisehir, Turkey
| | - Ö Irmak
- Department of Restorative Dentistry, Faculty of Dentistry, Cyprus Health and Social Sciences University, Guzelyurt, Turkey
| |
Collapse
|
2
|
Sakkaria A, Ramadoss R, Krishnasamy N, Sundar S, Panneerselvam S, Ramani P. Assessment of Nanoscale Configuration of Dentin in Non-carious Cervical Lesions. Cureus 2023; 15:e48003. [PMID: 38034251 PMCID: PMC10686805 DOI: 10.7759/cureus.48003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/29/2023] [Indexed: 12/02/2023] Open
Abstract
Introduction Non-carious cervical lesions (NCCLs) are structural deformities or tissue loss in the cervical region of teeth, which are closer to the gum line that do not result from caries (tooth decay). On the tooth enamel at the gingival margin, these lesions are frequently seen as V- or U-shaped notches. The causes of NCCLs are multifaceted and involve intricate relationships between chemical, mechanical, and biological elements. The slow loss of enamel and dentin in the cervical area occurs due to mechanical causes like abrasive toothbrushing and occlusal tension, as well as chemical variables such as erosive acidic food components. As NCCLs advance, dental discomfort, aesthetic issues, and impaired tooth function may result. The aim of this study was to assess the nanoscale configuration of dentin in non-carious cervical lesions using scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS). Methodology Sterilized teeth samples were selected from the extracted tooth repository of Saveetha Dental College and Hospitals, Chennai. Tooth samples were thinly sliced using a diamond bur. The sliced teeth were examined using a scanning electron microscope. Ionic configuration was assessed using EDS and elemental analysis. Results The findings showed the nanoscale morphology and elemental configurations present. Elemental mapping showed specific elemental localization in the affected area. Conclusion NCCLs can be attributed as a predominant factor leading to gingival recession causing dentin exposure and hypersensitivity. NCCLs can also threaten the integrity of dentin; therefore, early diagnosis of non-carious cervical lesions is crucial to ensure proper treatment plan and therapeutic regimens.
Collapse
Affiliation(s)
- Akshat Sakkaria
- Oral Biology, Saveetha Dental College and Hospitals, Chennai, IND
| | - Ramya Ramadoss
- Oral Biology, Saveetha Dental College and Hospitals, Chennai, IND
| | | | - Sandhya Sundar
- Oral Biology, Saveetha Dental College and Hospitals, Chennai, IND
| | | | - Pratibha Ramani
- Oral and Maxillofacial Pathology, Saveetha Dental College and Hospitals, Chennai, IND
| |
Collapse
|
3
|
Haak R, Stache G, Schneider H, Häfer M, Schmalz G, Schulz-Kornas E. Effect of the Adhesive Strategy on Clinical Performance and Marginal Integrity of a Universal Adhesive in Non-Carious Cervical Lesions in a Randomized 36-Month Study. J Clin Med 2023; 12:5776. [PMID: 37762718 PMCID: PMC10531668 DOI: 10.3390/jcm12185776] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 08/31/2023] [Accepted: 09/01/2023] [Indexed: 09/29/2023] Open
Abstract
The effectiveness of a universal adhesive applied in three application modes for the preparation of Class V composite restorations was evaluated both clinically and by quantitative marginal analysis (QMA) over 36 months. In 50 patients, three (n = 21) or four (n = 29) non-carious cervical lesions (NCCL) were restored with Venus® Diamond Flow (Kulzer GmbH, Hanau, Germany). The adhesive iBond® Universal (iBU, Kulzer, Germany) was used in self-etch (SE), etch-and-rinse (ER), or selective-enamel-etch mode (SEE). The etch-and-rinse adhesive OptiBondTM FL served as a control (OFL, Kerr GmbH, Herzogenrath, Germany). The restorations were clinically assessed (FDI criteria) at 14 days (BL), 6, 12, 24, and 36 months. Additionally, QMA was conducted on all restorations of 11 randomly selected patients. FDI criteria and marginal gap and perfect margin were compared between and within groups and recalls using McNemar, Wilcoxon, or Mann-Whitney U-tests (α = 0.05). Starting with 12 months, cumulative failure rates were lower in iBU-SE (0.0%, p = 0.016) and iBU-ER groups (2.1%, p = 0.07) compared to OFL (16.7%). At two years, iBU-SEE also showed fewer failures (0.0% SEE vs. 34.6% OFL, p = 0.016), as did iBU-SE compared to iBU-ER after 36 months (2.2 and 19.6%, p = 0.039). From BL, the iBU-SEE group always had the fewest marginal gaps and the highest percentage of perfect margins. From BL, iBU-SEE (0%, p = 0.008) and iBU-ER (0.2%, p = 0.027) showed significantly fewer marginal gaps compared to OFL (2.5%) and more perfect margins were found with iBU-SEE starting at 6 months (p = 0.054). The SEE and ER modes ensured the most excellent marginal quality, with differences from the control appearing earlier with QMA than clinically. In restoring NCCls, iBU showed superior clinical performance over OFL, especially in modes SE and SEE.
Collapse
Affiliation(s)
| | | | | | | | | | - Ellen Schulz-Kornas
- Department of Cariology, Endodontology and Periodontology, University of Leipzig, Liebigstraße 12, 04103 Leipzig, Germany
| |
Collapse
|
4
|
Chang KCJ, Mumford JH, Long A, Ton VH. Vestibular tunnel approach in restoring non-carious cervical lesion gingival recessions with combination of bioceramics and collagen matrix: A case report with a 1-year follow-up. Clin Adv Periodontics 2023; 13:56-61. [PMID: 35929734 DOI: 10.1002/cap.10222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2022] [Accepted: 07/30/2022] [Indexed: 01/31/2023]
Abstract
INTRODUCTION Non-carious cervical lesions (NCCLs) can compromise the integrity to both hard and soft tissues of teeth. This case report introduces a novel interdisciplinary technique by utilizing bioceramics-based cement (BBC) and porcine collagen matrix (CM) to reconstruct the dentogingival complex where enamel, dentin, and soft tissues were involved. CASE PRESENTATION A 38-year-old healthy male was referred to the periodontics department for gingival recessions teeth #27-29 and a deep (NCCL) on the facial (F) #28 involving the loss of the cementoenamel junction (CEJ). The F #28 was restored with BBC according to manufacturing instructions. Soft tissues of #27-29 were simultaneously augmented with two CM strips via a coronally advanced tunnel utilizing suspended sutures. At the 6-month follow-up, approximately 100% root coverages were obtained for #27 and 29. The F #28 gingival tissue stabilized at the anticipated level of maximum root coverage (MRC), 1 mm apical to the coronally displaced CEJ. The exposed layer of BBC, F #28, was veneered with resin-modified glass ionomer to re-establish the original position of the CEJ. At the one-year follow-up visit root coverage for #28 remained stable and probing depths remained unchanged at 2 mm F #27-29. A sectional cone beam computed tomography scan illustrated the BBC restoration remained intact and well adapted. CONCLUSION The 12-month follow-up illustrated that the BBC may be a viable restorable material while performing simultaneous gingival grafting with CM in deep NCCLs with gingival recessions. KEY POINTS Why is this case new information? A novel approach treating the deep non-carious cervical lesion with BBC and CM. What are the keys to successful management of this case? The BBC placement needs to be flat. Secure the surgical site with non-resorbable suspensory sutures fixed by flowable composite. What are the primary limitations to success in this case? The primary limitation to success is the blood moisture control which may limit the placement of collagen matrix strips via the portal entry.
Collapse
Affiliation(s)
- Kai-Chiao Joe Chang
- Department of Periodontics, Arizona School of Dentistry and Oral Health, A.T. Still University, Mesa, Arizona, USA
| | - John H Mumford
- Private Practice, CAPT (Ret) United States Navy, Boise, Idaho, USA
| | - Alex Long
- Department of Periodontics, Naval Postgraduate Dental School, Bethesda, Maryland, USA
| | - Vinh H Ton
- Division of Periodontics, Naval Dental Center/1st Dental Battalion, Camp Pendleton, California, USA
| |
Collapse
|
5
|
Hamza B, Martinola L, Körner P, Gubler A, Attin T, Wegehaupt FJ. Effect of brushing force on the abrasive dentin wear using slurries with different abrasivity values. Int J Dent Hyg 2023; 21:172-177. [PMID: 36057452 PMCID: PMC10086971 DOI: 10.1111/idh.12620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 05/02/2022] [Accepted: 08/30/2022] [Indexed: 01/12/2023]
Abstract
OBJECTIVE The aim of this study was to investigate the resulting abrasive dentin wear using abrasive slurries with different RDA values and applying increasing brushing forces. METHODS Forty-five bovine incisors were randomly allocated in three groups (A, B, C, n = 15). One hundred and eighty dentin samples were prepared from these incisors and allocated to twelve groups (A1-A4, B1-B4, C1-C4; n = 15). The groups were subjected to a brushing cycle (120 strokes/min, 25 min) as follows: groups A1 to A4 with an abrasive slurry (RDA = 71) applying increasing brushing forces (1, 2, 3 and 4 N). Groups B1 to B4 were brushed using an abrasive slurry (RDA = 85) and C1 to C4 (RDA = 133) applying the same above-mentioned brushing forces. Abrasive dentin wear was recorded using a stylus profilometer and compared amongst the groups using robust models. Pairwise comparisons in each model were tested and corrected after Tukey's method (α = 0.05). RESULTS Applying 1-N brushing force resulted in the same amount of abrasive dentin wear in all groups regardless of the abrasivity of the used slurry. Increasing the brushing force to 2 N resulted in statistically significantly higher abrasive wear in all groups. This increase in abrasive wear was much higher when the slurry with high abrasivity was used (RDA = 133) compared with the lower abrasive slurry (RDA = 71). CONCLUSION The abrasivity of the used slurry does not add to the resulting abrasive wear when the brushing force is kept at 1 N. It seems better to advise and help the patients (showing signs of non-carious cervical lesions) calibrating their brushing force to 1 N, than only to advise them to use toothpastes with lower abrasivities.
Collapse
Affiliation(s)
- Blend Hamza
- Clinic of Orthodontics and Pediatric dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Laura Martinola
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Philipp Körner
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Andrea Gubler
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Thomas Attin
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Florian Just Wegehaupt
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
6
|
Nam J, Nguyen DH, Lee S, Heo SM, Park J. Simulation of Non-Carious Cervical Lesions by Computational Toothbrush Model: A Novel Three-Dimensional Discrete Element Method. Sensors (Basel) 2022; 22:s22114183. [PMID: 35684809 PMCID: PMC9185324 DOI: 10.3390/s22114183] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2022] [Revised: 05/28/2022] [Accepted: 05/28/2022] [Indexed: 06/01/2023]
Abstract
Non-carious cervical lesions (NCCLs) are saucer-shaped abrasions of a tooth. NCCLs can form due to various etiologies, including toothbrushing wear, acid erosion, and mechanical stress. Owing to this complex interplay, the mechanism of NCCLs in tooth abrasion has not been established. This study aims to develop a numerical method using a computational toothbrush to simulate NCCLs. The forces acting on the teeth and the amount of abrasion generated were evaluated. The discrete element method using in-house code, connected particle model, and Archard wear model were applied for brushing. In the toothbrush model, 42 acrylic tufts were fixed into a toothbrush head. The teeth models with enamel properties comprised four flat plates and two grooves to simulate the anterior teeth and NCCLs. The brushing speed and depth for one cycle were established as simulation parameters. The force applied within the ununiform plane was concentrated on several bristles as the toothbrush passed through the interproximal space. The brushing force (depth) had a greater effect on tooth abrasion than the brushing speed. Toothbrushing abrasion was mainly concentrated in the interproximal space. Therefore, forceful tooth brushing can cause NCCLs from the interproximal space to the cervical area of the tooth.
Collapse
Affiliation(s)
- Jinsu Nam
- Department of Mechanical Design Engineering, Kumoh National Institute of Technology, 61, Daehak-Ro, Gumi 39177, Gyeungbuk, Korea; (J.N.); (S.L.)
| | - Duong Hong Nguyen
- Techno Vietnam Co., JSC., TSQ Living Area (Euroland), Mo Lao Ward, Ha Dong District, Hanoi City 12110, Vietnam;
| | - Seungjun Lee
- Department of Mechanical Design Engineering, Kumoh National Institute of Technology, 61, Daehak-Ro, Gumi 39177, Gyeungbuk, Korea; (J.N.); (S.L.)
- Department of Aeronautic, Mechanical and Electrical Convergence Engineering, Kumoh National Institute of Technology, 61, Daehak-Ro, Gumi 39177, Gyeungbuk, Korea
| | - Seok-Mo Heo
- Department of Periodontology, School of Dentistry, Jeonbuk National University, Jeonju 54907, Jeonbuk, Korea
| | - Junyoung Park
- Department of Mechanical Design Engineering, Kumoh National Institute of Technology, 61, Daehak-Ro, Gumi 39177, Gyeungbuk, Korea; (J.N.); (S.L.)
- Department of Aeronautic, Mechanical and Electrical Convergence Engineering, Kumoh National Institute of Technology, 61, Daehak-Ro, Gumi 39177, Gyeungbuk, Korea
| |
Collapse
|
7
|
Stănuși A, Ionescu M, Cerbulescu C, Popescu SM, Osiac E, Mercuț R, Scrieciu M, Pascu RM, Stănuși AŞ, Mercuț V. Modifications of the Dental Hard Tissues in the Cervical Area of Occlusally Overloaded Teeth Identified Using Optical Coherence Tomography. Medicina (Kaunas) 2022; 58:702. [PMID: 35743966 DOI: 10.3390/medicina58060702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Revised: 05/15/2022] [Accepted: 05/23/2022] [Indexed: 11/16/2022]
Abstract
Background and objectives: Occlusal overloads produce a series of manifestations in teeth, especially attrition and non-carious cervical lesions (NCCL). Optical Coherence Tomography (OCT) can highlight and evaluate tooth lesions. The aim of this study was to examine the changes of dental hard tissues in the cervical area because of occlusal overload by macroscopic examination and using in vitro Swept Source OCT examination. Materials and Methods: The study was performed on 21 extracted teeth with occlusal trauma. After macroscopic and OCT examination, the 2D OCT images were transformed into 3D images using ImageJ software. Statistical analysis of macroscopic and OCT images was performed with Statistical Package for Social Sciences. Results: On 21 teeth, 88 cervical lesions (cracks) were identified. Upper premolars with an occlusal Smith and Knight tooth wear score of 2 had the most NCCL. Statistical analysis revealed significant differences in the median widths of cervical lesions between teeth with score 1 and score 3. Additionally, we obtained statistically significant differences in median widths between the buccal and oral surfaces. Conclusions: These cracks can be considered precursors of NCCL. NCCL can be located on dental surfaces in the cervical area other than the buccal one. A 3D reconstruction of OCT images emphasized that cracks are located especially at enamel level, evolving towards the enamel-dentin junction, with multiple ramifications.
Collapse
|
8
|
Göstemeyer G, Seifert T, Jeggle-Engbert LM, Paris S, Schwendicke F. Glass Hybrid Versus Nanocomposite for Restoration of Sclerotic Non-carious Cervical Lesions: 18-Month Results of a Randomized Controlled Trial. J Adhes Dent 2021; 23:487-496. [PMID: 34817964 DOI: 10.3290/j.jad.b2287831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
PURPOSE To compare the clinical performance and treatment times between glass hybrid (GH; EQUIA Forte Fil/EQUIA Forte Coat, GC) and adhesive/nanofilled resin composite restorations (RC; OptiBond FL, Kerr/Filtek Supreme XTE, 3M Oral Care) of sclerotic non-carious cervical lesions (sNCCL). MATERIALS AND METHODS This is an 18-month interim analysis of a 36-month cluster-randomized trial (ClinicalTrials.gov Identifier: NCT02631161). Eighty-eight patients (50-70 years) with 175 sNCCLs were randomized to receive GH or RC restorations. Restorations were placed without mechanical cavity preparation, and treatment time was recorded. After 18 months, restorations were evaluated using FDI criteria. Factors associated with restoration survival were evaluated using multi-level Cox-regression analysis. Generalized linear mixed modelling was used to analyze factors associated with treatment time. RESULTS After a mean of 18 months (min/max: 8/25), 78 patients (160 restorations) were assessed. Fifteen restorations (18%) failed in GH, and 11 (12%) in the RC, without a significant difference in survival (p = 0.904/Cox). Retention loss was the most common reason for failure in both groups. Restorations placed in older patients showed lower risk of failure [OR (95% CI): 0.90 (0.81-0.99) per year], while mandibular teeth showed higher risks [2.89 (1.00-8.31)]. Treatment time was significantly shorter for GH (mean ± SD: 8.6 ± 4.3 min) than RC (11.7 ± 5.7 min; p < 0.001). CONCLUSIONS GH may be a suitable alternative to RC for restoring sNCCLs, without any significant difference in survival between the two materials at this interim analysis. In addition, placing GH restorations required less chairtime than did placing RC restorations.
Collapse
|
9
|
Akarsu S, Karademir SA, Ertas E, Atasoy S. The effect of diode laser application on restoration of non carious cervical lesion: Clinical follow up. Niger J Clin Pract 2020; 23:165-171. [PMID: 32031090 DOI: 10.4103/njcp.njcp_399_19] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
Aims The aim of this study is to evaluate the effect of the diode laser used for dentin sensitivity on the clinical success of non-carious cervical lesion (NCCL) restorations restored with different adhesive systems. Methods 20 NCCLs were restorated with Universal Single Bond (Self Etch) (3M, USA) and Grandio (Voco, Germany), 20 NCCLs were restorated with Universal Single Bond (Total Etch) and Grandio. After diode laser application, 20 NCCLs were restorated with Universal Single Bond and Grandio, 20 NCCLs were restorated with Universal Single Bond (Total Etch) and Grandio. The restorations were clinical evaluated by two examiners at baseline, for 6 and 18 months using modified United States Public Health Service (USPHS) Criteria. Chi-square test was used for statistical analyse. Results The lowest rates of retention was found in the Group 1. There was no statistically significant difference among the groups in marginal discoloration, marginal integrity, sensitivity (P > 0.05). Conclusion Diode laser application prior to the restoration of teeth with NCCL don't reduce the retention rate of restorations, may reduce hypersensitivity and may affect the success of restoration. However, further laboratory and clinical studies are required.
Collapse
Affiliation(s)
- S Akarsu
- Department of Restorative Dentistry, Faculty of Dentistry, Ordu University, Ordu, Turkey
| | - S A Karademir
- Department of Restorative Dentistry, Faculty of Dentistry, Ordu University, Ordu, Turkey
| | - E Ertas
- Department of Restorative Dentistry, Faculty of Dentistry, OndokuzMayıs University, Samsun, Turkey
| | - S Atasoy
- Department of Restorative Dentistry, Faculty of Dentistry, Ordu University, Ordu, Turkey
| |
Collapse
|
10
|
Manarte-Monteiro P, Domingues J, Teixeira L, Gavinha S, Manso MC. Multi-Mode adhesives performance and success/retention rates in NCCLs restorations: randomised clinical trial one-year report. Biomater Investig Dent 2019; 6:43-53. [PMID: 31998871 PMCID: PMC6964776 DOI: 10.1080/26415275.2019.1684199] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Accepted: 09/23/2019] [Indexed: 11/24/2022] Open
Abstract
Aim: Compare clinical performance and success/retention rates of two multi-mode (MM) adhesives, applied in self-etch (SE) or etch-and-rinse (ER) modes, with SE-all-in-one adhesive (SE/SE with enamel etching) in NCCL restorations at one-year follow-up. Material and methods: Prospective, double-blind RCT approved by the University Fernando Pessoa and the National-Clinical-Research-Ethics Committees (CEIC-20150305), ClinicalTrials.gov registered (NCT02698371), in 38 participants with 210 restorations (AdmiraFusion®) randomly allocated to six groups (Adhesives_Adhesion mode), each with 35 restorations: G1-Control Futurabond®DC_SE; G2-Control Futurabond®DC_SE with enamel etching; G3-Futurabond®U_ER; G4-Futurabond®U_SE; G5-Adhese®Universal_ER; G6-Adhese®Universal_SE. Restorations evaluated at baseline and one-year by three calibrated examiners (ICC ≥0.952) using FDI criteria and statistical analysis with nonparametric tests (alpha = 0.05). Results: At one-year recall 36 participants, 199 restorations were available for examination; five (2.5%) restorations (G1 n = 2; G2, G3, G4 n = 1) were lost due to retention (p > .05); G1 showed less satisfying marginal adaptation (p < .05) than G2 and MM adhesives groups, particularly G6. Overall success rates (p > .05) were: 93.9% (G1), 97.0% (G2; G3; G4) and 100.0% (G5; G6). Conclusions: MM adhesives (Futurabond®U and Adhese®Universal) showed similar and acceptable performance/success rates but also better clinical outputs than the SE-all-in-one adhesive (Futurabond®DC), particularly in SE mode. Success and retention rates were similar and not dependent on materials or adhesion modes.
Collapse
Affiliation(s)
- Patrícia Manarte-Monteiro
- Department of Medical Sciences, Faculty of Health Sciences, University Fernando Pessoa, Porto, Portugal
| | - Joana Domingues
- Department of Medical Sciences, Faculty of Health Sciences, University Fernando Pessoa, Porto, Portugal
| | - Liliana Teixeira
- Department of Medical Sciences, Faculty of Health Sciences, University Fernando Pessoa, Porto, Portugal
| | - Sandra Gavinha
- Department of Medical Sciences, Faculty of Health Sciences, University Fernando Pessoa, Porto, Portugal
| | - Maria Conceição Manso
- Biostatistics, Faculty of Health Sciences, UFP Energy, Environment and Health Research Unit (FP-ENAS), University Fernando Pessoa, Porto, Portugal
| |
Collapse
|
11
|
Ying X, Chen Y, Zhang KL. [Modified tunnel technique applied in the treatment of gingival recessions with non-carious cervical lesion]. Hua Xi Kou Qiang Yi Xue Za Zhi 2019; 37:496-500. [PMID: 31721496 DOI: 10.7518/hxkq.2019.05.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
OBJECTIVE This study aimed to investigate the clinical effect of modified tunnel technique (MTUN) in the treatment of gingival recession with non-carious cervical lesion (NCCL). METHODS Forty-two teeth with Miller I degree gingival recession were divided into the NCCL group or control group depending on whether NCCL was present. Both groups were treated with MTUN plus subepithelial connective tissue. The periodontal probing depth (PD), gingival recession height (GRH), gingival recession width (GRW), attached gingival width (AGW), and clinical attachment loss (CAL) were recorded before and at 3 and 6 months after operation. The mean root coverage (MRC) at 6 months after operation was calculated and analyzed. A root coverage esthetic scoring system was used to record aesthetic scores. RESULTS GRH, GRW, and CAL of the two groups after surgery were significantly lower than those before surgery, and no significant changes in PD and AGW were observed. The MRC in the NCCL group was 63.40%±28.02%, whereas that in the control group was 67.00%±21.72%; no significant difference between the two groups was found. In terms of aesthetic outcomes, no significant difference between groups was reported. CONCLUSIONS MTUN can effectively improve gingival recession, and the presence of shallow NCCL (≤1 mm) will not affect the surgical effect of MTUN.
Collapse
Affiliation(s)
- Xuan Ying
- Dept. of Periodontology, College of Stomatology, Xi'an Jiaotong University, Xi'an 710004, China
| | - Yue Chen
- Dept. of Periodontology, College of Stomatology, Xi'an Jiaotong University, Xi'an 710004, China
| | - Kai-Li Zhang
- Dept. of Periodontology, College of Stomatology, Xi'an Jiaotong University, Xi'an 710004, China
| |
Collapse
|
12
|
Zeola LF, Pereira FA, Machado AC, Reis BR, Kaidonis J, Xie Z, Townsend GC, Ranjitkar S, Soares PV. Effects of non-carious cervical lesion size, occlusal loading and restoration on biomechanical behaviour of premolar teeth. Aust Dent J 2017; 61:408-417. [PMID: 26671647 DOI: 10.1111/adj.12391] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/06/2015] [Indexed: 11/28/2022]
Abstract
BACKGROUND Information on fracture biomechanics has implications in materials research and clinical practice. The aim of this study was to analyse the influence of non-carious cervical lesion (NCCL) size, restorative status and direction of occlusal loading on the biomechanical behaviour of mandibular premolars, using finite element analysis (FEA), strain gauge tests and fracture resistance tests. METHODS Ten buccal cusps were loaded on the outer and inner slopes to calculate the strain generated cervically. Data were collected for healthy teeth at baseline and progressively at three lesion depths (0.5 mm, 1.0 mm and 1.5 mm), followed by restoration with resin composite. The magnitude and distribution of von Mises stress and maximum principal stress were simulated at all stages using FEA, and fracture strength was also determined (n = 7 per group). RESULTS There were significant effects of the lesion size and loading directions on stress, strain and fracture resistance (p < 0.05). Fracture resistance values decreased with increase in lesion size, but returned to baseline with restorations. CONCLUSIONS Combined assessment of computer-based and experimental techniques provide an holistic approach to characterize the biomechanical behaviour of teeth with both unrestored and restored NCCLs.
Collapse
Affiliation(s)
- L F Zeola
- Operative Dentistry and Dental Materials Department, School of Dentistry, Federal University of Uberlandia, Brazil
| | - F A Pereira
- Operative Dentistry and Dental Materials Department, School of Dentistry, Federal University of Uberlandia, Brazil
| | - A C Machado
- Operative Dentistry and Dental Materials Department, School of Dentistry, Federal University of Uberlandia, Brazil
| | - B R Reis
- Federal University of Uberlandia, Brazil
| | - J Kaidonis
- School of Mechanical Engineering, The University of Adelaide, South Australia, Australia
| | - Z Xie
- School of Dentistry, The University of Adelaide, South Australia, Australia
| | - G C Townsend
- School of Mechanical Engineering, The University of Adelaide, South Australia, Australia
| | - S Ranjitkar
- School of Mechanical Engineering, The University of Adelaide, South Australia, Australia
| | - P V Soares
- Operative Dentistry and Dental Materials Department, School of Dentistry, Federal University of Uberlandia, Brazil
| |
Collapse
|
13
|
Abstract
Abfraction (AF) is the pathological loss of tooth substance caused by biomechanical loading forces that result in flexure and failure of enamel and dentin at a location away from the loading. The theory of AF is based primarily on engineering analyses that demonstrate theoretical stress concentration at the cervical areas of the teeth. However, the theory is not yet proven and there are explanations against it. AF lesions present primarily at the cervical region of the dentition and are typically wedge-shaped, with sharp internal and external line angles. Diagnosis of AF plays a very important role in the management of patients. The aim of the present narrative review is to comprehensively discuss the historical, etiopathogenetic, clinical, and diagnostic and treatment aspects of AF.
Collapse
Affiliation(s)
- Gargi S Sarode
- Department of Oral Pathology and Microbiology, Dr. D. Y. Patil Dental College and Hospital, Dr. D.Y. Patil Vidyapeeth, Sant-Tukaram Nagar, Pimpri, Pune, Maharashtra, India
| | | |
Collapse
|