1
|
A Review on Biological Effects of Ultrasounds: Key Messages for Clinicians. Diagnostics (Basel) 2023; 13:855. [PMID: 36899998 PMCID: PMC10001275 DOI: 10.3390/diagnostics13050855] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 02/18/2023] [Accepted: 02/21/2023] [Indexed: 02/25/2023] Open
Abstract
Ultrasound (US) is acoustic energy that interacts with human tissues, thus, producing bioeffects that may be hazardous, especially in sensitive organs (i.e., brain, eye, heart, lung, and digestive tract) and embryos/fetuses. Two basic mechanisms of US interaction with biological systems have been identified: thermal and non-thermal. As a result, thermal and mechanical indexes have been developed to provide a means of assessing the potential for biological effects from exposure to diagnostic US. The main aims of this paper were to describe the models and assumptions used to estimate the "safety" of acoustic outputs and indices and to summarize the current state of knowledge about US-induced effects on living systems deriving from in vitro models and in vivo experiments on animals. This review work has made it possible to highlight the limits associated with the use of the estimated safety values of thermal and mechanical indices relating above all to the use of new US technologies, such as contrast-enhanced ultrasound (CEUS) and acoustic radiation force impulse (ARFI) shear wave elastography (SWE). US for diagnostic and research purposes has been officially declared safe, and no harmful biological effects in humans have yet been demonstrated with new imaging modalities; however, physicians should be adequately informed on the potential risks of biological effects. US exposure, according to the ALARA (As Low As Reasonably Achievable) principle, should be as low as reasonably possible.
Collapse
|
2
|
Image-Guided Measurement of Radiation Force Induced by Focused Ultrasound Beams. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; 70:138-146. [PMID: 36350863 PMCID: PMC10079628 DOI: 10.1109/tuffc.2022.3221049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
The radiation force balance (RFB) is a widely used method for measuring acoustic power output of ultrasonic transducers. The reflecting cone target is attractive due to its simplicity and long-term stability, at a reasonable cost. However, accurate measurements using this method depend on the alignment between the ultrasound beam and cone axes, especially for highly focused beams utilized in therapeutic applications. With the advent of dual-mode ultrasound arrays (DMUAs) for imaging and therapy, image-guided measurements of acoustic output using the RFB method can be used to improve measurement accuracy. In this article, we describe an image-guided RFB measurement of focused DMUA beams using a widely used commercial instrument. DMUA imaging is used to optimize the alignment between the acoustic beam and reflecting cone axes. In addition to image-guided alignment, DMUA echo data is used to track the displacement of the cone, which provides an auxiliary measurement of acoustic power. Experimental results using a DMUA prototype with [Formula: see text] shows that 1-2 mm of misalignment can result in 5%-14% error in the measured acoustic power. In addition to the use of B-mode image guidance for improving measurement accuracy, we present preliminary results demonstrating the benefit of displacement tracking using real-time DMUA imaging during the application of (sub)therapeutic focused beams. Displacement tracking provides a direct measurement of the radiation force with high sensitivity and follows the expected dependence on changes in amplitude and duty cycle (DC) of the focused ultrasound (FUS) beam. This could lead to simpler, more reliable methods for measuring acoustic power based on the radiation force principle. Combined with appropriate computational modeling, the direct measurement of acoustic radiation force could lead to reliable dosimetry in situ in emerging applications such as transcranial FUS (tFUS) therapies.
Collapse
|
3
|
Measuring the Compressibility of Cellulose Nanofiber-Stabilized Microdroplets Using Acoustophoresis. MICROMACHINES 2021; 12:mi12121465. [PMID: 34945315 PMCID: PMC8707857 DOI: 10.3390/mi12121465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 11/24/2021] [Accepted: 11/25/2021] [Indexed: 11/16/2022]
Abstract
Droplets with a liquid perfluoropentane core and a cellulose nanofiber shell have the potential to be used as drug carriers in ultrasound-mediated drug delivery. However, it is necessary to understand their mechanical properties to develop ultrasound imaging sequences that enable in vivo imaging of the vaporization process to ensure optimized drug delivery. In this work, the compressibility of droplets stabilized with cellulose nanofibers was estimated using acoustophoresis at three different acoustic pressures. Polyamide particles of known size and material properties were used for calibration. The droplet compressibility was then used to estimate the cellulose nanofiber bulk modulus and compare it to experimentally determined values. The results showed that the acoustic contrast factor for these droplets was negative, as the droplets relocated to pressure antinodes during ultrasonic actuation. The droplet compressibility was 6.6–6.8 ×10−10 Pa−1, which is higher than for water (4.4×10−10 Pa−1) but lower than for pure perfluoropentane (2.7×10−9 Pa−1). The compressibility was constant across different droplet diameters, which was consistent with the idea that the shell thickness depends on the droplet size, rather than being constant.
Collapse
|
4
|
Simultaneous Trapping of Two Types of Particles with Focused Elegant Third-Order Hermite-Gaussian Beams. MICROMACHINES 2021; 12:mi12070769. [PMID: 34210060 PMCID: PMC8308001 DOI: 10.3390/mi12070769] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 06/26/2021] [Accepted: 06/28/2021] [Indexed: 11/16/2022]
Abstract
The focusing properties of elegant third-order Hermite-Gaussian beams (TH3GBs) and the radiation forces exerted on dielectric spherical particles produced by such beams in the Rayleigh scattering regime have been theoretically studied. Numerical results indicate that the elegant TH3GBs can be used to simultaneously trap and manipulate nanosized dielectric spheres with refractive indexes lower than the surrounding medium at the focus and those with refractive indexes larger than the surrounding medium in the focal vicinity. Furthermore, by changing the radius of the beam waist, the transverse trapping range and stiffness at the focal plane can be changed.
Collapse
|
5
|
Radiation Force as a Physical Mechanism for Ultrasonic Neurostimulation of the Ex Vivo Retina. J Neurosci 2019; 39:6251-6264. [PMID: 31196935 DOI: 10.1523/jneurosci.2394-18.2019] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Revised: 05/23/2019] [Accepted: 05/30/2019] [Indexed: 12/23/2022] Open
Abstract
Focused ultrasound has been shown to be effective at stimulating neurons in many animal models, both in vivo and ex vivo Ultrasonic neuromodulation is the only noninvasive method of stimulation that could reach deep in the brain with high spatial-temporal resolution, and thus has potential for use in clinical applications and basic studies of the nervous system. Understanding the physical mechanism by which energy in a high acoustic frequency wave is delivered to stimulate neurons will be important to optimize this technology. We imaged the isolated salamander retina of either sex during ultrasonic stimuli that drive ganglion cell activity and observed micron scale displacements, consistent with radiation force, the nonlinear delivery of momentum by a propagating wave. We recorded ganglion cell spiking activity and changed the acoustic carrier frequency across a broad range (0.5-43 MHz), finding that increased stimulation occurs at higher acoustic frequencies, ruling out cavitation as an alternative possible mechanism. A quantitative radiation force model can explain retinal responses and could potentially explain previous in vivo results in the mouse, suggesting a new hypothesis to be tested in vivo Finally, we found that neural activity was strongly modulated by the distance between the transducer and the electrode array showing the influence of standing waves on the response. We conclude that radiation force is the dominant physical mechanism underlying ultrasonic neurostimulation in the ex vivo retina and propose that the control of standing waves is a new potential method to modulate these effects.SIGNIFICANCE STATEMENT Ultrasonic neurostimulation is a promising noninvasive technology that has potential for both basic research and clinical applications. The mechanisms of ultrasonic neurostimulation are unknown, making it difficult to optimize in any given application. We studied the physical mechanism by which ultrasound is converted into an effective energy form to cause neurostimulation in the retina and find that ultrasound acts via radiation force leading to a mechanical displacement of tissue. We further show that standing waves have a strong modulatory effect on activity. Our quantitative model by which ultrasound generates radiation force and leads to neural activity will be important in optimizing ultrasonic neurostimulation across a wide range of applications.
Collapse
|
6
|
Plane-Wave Contrast Imaging: A Radiation Force Point of View. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:2296-2300. [PMID: 29994658 PMCID: PMC6321741 DOI: 10.1109/tuffc.2018.2847899] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Radiation force is known to produce microbubble axial displacements by an amount that depends on the transmit burst frequency, amplitude, and length, as well as the pulse repetition frequency (PRF). In the standard focused-imaging mode, the actual PRF experienced by each microbubble is low, because it is of the order of the frame rate (i.e., usually tens of Hertz). In the plane-wave imaging mode, however, the actual PRF is considerably higher, as it is equivalent to the transmit PRF (kiloHertz range). Furthermore, the radiation pressure is expected to be almost uniform over the field of view, and typically lower than the peak pressure experienced in the focused transmit (TX) mode. We have experimentally investigated the possible effects of radiation force in the plane-wave mode. Here, we report on preliminary findings that show that the acoustic radiation force is negligible only at lower TX levels. At higher TX amplitudes, the bubble displacements due to radiation force are comparable to those obtained for focused waves at the same PRF. In addition, the radiation force is nearly uniform over the field of view and increases as the TX burst central frequency approaches the resonance frequency of size-isolated microbubbles.
Collapse
|
7
|
Acoustic Radiation Force of a Quasi-Gaussian Beam on an Elastic Sphere in a Fluid. IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM : [PROCEEDINGS]. IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM 2017; 2016. [PMID: 28593033 DOI: 10.1109/ultsym.2016.7728608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Acoustic radiation force has many applications. One of the related technologies is the ability to noninvasively expel stones from the kidney. To optimize the procedure it is important to develop theoretical approaches that can provide rapid calculations of the radiation force depending in stone size and elastic properties, together with ultrasound beam diameter, intensity, and frequency. We hypothesize that the radiation force nonmonotonically depends on the ratio between the acoustic beam width and stone diameter because of coupling between the acoustic wave in the fluid and shear waves in the stone. Testing this hypothesis by considering a spherical stone and a quasi-Gaussian beam was performed in the current work. The calculation of the radiation force was conducted for elastic spheres of two types. Dependence of the magnitude of the radiation force on the beam diameter at various fixed values of stone diameters was modeled. In addition to using real material properties, speed of shear wave in the stone was varied to reveal the importance of shear waves in the stone. It was found that the radiation force reaches its maximum at the beamwidth comparable to the stone diameter; the gain in the force magnitude can reach 40% in comparison with the case of a narrow beam.
Collapse
|
8
|
An in vivo validation of the application of acoustic radiation force to enhance the diagnostic utility of molecular imaging using 3-d ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:651-60. [PMID: 22341052 PMCID: PMC3355521 DOI: 10.1016/j.ultrasmedbio.2011.12.005] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2011] [Revised: 11/29/2011] [Accepted: 12/01/2011] [Indexed: 05/21/2023]
Abstract
For more than a decade, the application of acoustic radiation force (ARF) has been proposed as a mechanism to increase ultrasonic molecular imaging (MI) sensitivity in vivo. Presented herein is the first noninvasive in vivo validation of ARF-enhanced MI with an unmodified clinical system. First, an in vitro optical-acoustical setup was used to optimize system parameters and ensure sufficient microbubble translation when exposed to ARF. 3-D ARF-enhanced MI was then performed on 7 rat fibrosarcoma tumors using microbubbles targeted to α(v)β₃ and nontargeted microbubbles. Low-amplitude (<25 kPa) 3-D ARF pulse sequences were tested and compared with passive targeting studies in the same animal. Our results demonstrate that a 78% increase in image intensity from targeted microbubbles can be achieved when using ARF relative to the passive targeting studies. Furthermore, ARF did not significantly increase image contrast when applied to nontargeted agents, suggesting that ARF did not increase nonspecific adhesion.
Collapse
|
9
|
Integration of crawling waves in an ultrasound imaging system. Part 1: system and design considerations. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:296-311. [PMID: 22178166 PMCID: PMC3254834 DOI: 10.1016/j.ultrasmedbio.2011.10.026] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2011] [Revised: 10/06/2011] [Accepted: 10/29/2011] [Indexed: 05/04/2023]
Abstract
An ultrasound system (GE Logiq 9) was modified to produce a synthetic crawling wave using shear wave displacements generated by the radiation force of focused beams formed at the left and the right edge of the region of interest (ROI). Two types of focusing, normal and axicon, were implemented. Baseband (IQ) data was collected to determine the left and right displacements, which were then used to calculate an interference pattern. By imposing a variable delay between the two pushes, the interference pattern moves across the ROI to produce crawling waves. Also temperature and pressure measurements were made to assess the safety issues. The temperature profiles measured in a veal liver along the focal line showed the maximum temperature rise less than 0.8°C, and the pressure measurements obtained in degassed water and derated by 0.3 dB/cm/MHz demonstrate that the system can operate within FDA safety guidelines.
Collapse
|
10
|
Integration of crawling waves in an ultrasound imaging system. Part 2: signal processing and applications. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:312-23. [PMID: 22178168 PMCID: PMC3254836 DOI: 10.1016/j.ultrasmedbio.2011.10.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2011] [Revised: 09/23/2011] [Accepted: 10/16/2011] [Indexed: 05/04/2023]
Abstract
This paper introduces methods to generate crawling wave interference patterns from the displacement fields generated from radiation force pushes on a GE Logiq 9 scanner. The same transducer and system provides both the pushing pulses to generate the shear waves and the tracking pulses to measure the displacements. Acoustic power and system limitations result in largely impulsive displacement fields. Measured displacements from pushes on either side of a region-of-interest (ROI) are used to calculate continuously varying interference patterns. This technique is explained along with a brief discussion of the conventional mechanical source-driven crawling waves for comparison. We demonstrate the method on three example cases: a gelatin-based phantom with a cylindrical inclusion, an oil-gelatin phantom and mouse livers. The oil-gelatin phantom and the mouse livers demonstrate not only shear speed estimation, but the frequency dependence of the shear wave speeds.
Collapse
|
11
|
Vibro-acoustography and multifrequency image compounding. ULTRASONICS 2011; 51:689-96. [PMID: 21377181 PMCID: PMC3090462 DOI: 10.1016/j.ultras.2011.02.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2009] [Revised: 01/30/2011] [Accepted: 02/08/2011] [Indexed: 05/26/2023]
Abstract
Vibro-acoustography is an ultrasound based imaging modality that can visualize normal and abnormal soft tissue through mapping the acoustic response of the object to a harmonic radiation force at frequency Δf induced by focused ultrasound. In this method, the ultrasound energy is converted from high ultrasound frequencies to a low acoustic frequency (acoustic emission) that is often two orders of magnitude smaller than the ultrasound frequency. The acoustic emission is normally detected by a hydrophone. Depending on the setup, this low frequency sound may reverberate by object boundaries or other structures present in the acoustic paths before it reaches the hydrophone. This effect produces an artifact in the image in the form of gradual variations in image intensity that may compromise image quality. The use of tonebursts with finite length yields acoustic emission at Δf and at sidebands centered about Δf. Multiple images are formed by selectively applying bandpass filters on the acoustic emission at Δf and the associated sidebands. The data at these multiple frequencies are compounded through both coherent and incoherent processes to reduce the acoustic emission reverberation artifacts. Experimental results from a urethane breast phantom are described. The coherent and incoherent compounding of multifrequency data show, both qualitatively and quantitatively, the efficacy of this reverberation reduction method. This paper presents theory describing the physical origin of this artifact and use of image data created using multifrequency vibro-acoustography for reducing reverberation artifacts.
Collapse
|
12
|
Abstract
Ultrasound-guided needle placement is widely used in the clinical setting, particularly for central venous catheter placement, tissue biopsy and regional anesthesia. Difficulties with ultrasound guidance in these areas often result from steep needle insertion angles and spatial offsets between the imaging plane and the needle. Acoustic Radiation Force Impulse (ARFI) imaging leads to improved needle visualization because it uses a standard diagnostic scanner to perform radiation force based elasticity imaging, creating a displacement map that displays tissue stiffness variations. The needle visualization in ARFI images is independent of needle-insertion angle and also extends needle visibility out of plane. Although ARFI images portray needles well, they often do not contain the usual B-mode landmarks. Therefore, a three-step segmentation algorithm has been developed to identify a needle in an ARFI image and overlay the needle prediction on a coregistered B-mode image. The steps are: (1) contrast enhancement by median filtration and Laplacian operator filtration, (2) noise suppression through displacement estimate correlation coefficient thresholding and (3) smoothing by removal of outliers and best-fit line prediction. The algorithm was applied to data sets from horizontal 18, 21 and 25 gauge needles between 0-4 mm offset in elevation from the transducer imaging plane and to 18G needles on the transducer axis (in plane) between 10 degrees and 35 degrees from the horizontal. Needle tips were visualized within 2 mm of their actual position for both horizontal needle orientations up to 1.5 mm offset in elevation from the transducer imaging plane and on-axis angled needles between 10 degrees-35 degrees above the horizontal orientation. We conclude that segmented ARFI images overlaid on matched B-mode images hold promise for improved needle visibility in many clinical applications.
Collapse
|
13
|
Dual frequency method for simultaneous translation and real-time imaging of ultrasound contrast agents within large blood vessels. ULTRASOUND IN MEDICINE & BIOLOGY 2009; 35:2021-30. [PMID: 19828229 PMCID: PMC2790010 DOI: 10.1016/j.ultrasmedbio.2009.07.003] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2009] [Revised: 06/26/2009] [Accepted: 07/21/2009] [Indexed: 05/07/2023]
Abstract
A dual frequency excitation method for simultaneous translation and selective real-time imaging of microbubbles is presented. The method can distinguish signals originating from free flowing and static microbubbles. This method is implemented on a programmable scanner with a broadband linear array. The programmable interface allows for dynamic variations in the acoustic parameters and aperture attributes, enabling application of this method to large blood vessels located at varying depths. The performance of the method was evaluated in vitro (vessel diameter 2mm) by quantifying the sensitivity of the method to various acoustic, microbubble, and fluid flow parameters. It was observed that the static microbubble response maximized at the approximate resonance frequency of the microbubble population (estimated from a coulter counter measurement), thus, signifying the need for dual frequency excitation. The static microbubble signal declined from 25 to 12 dB with increasing centerline flow velocities (2.65-15.9cm/s); indicating the applicable range of flow velocities. The maximum intensity of the static microbubbles signal scaled with variations in the microbubble concentration. The rate of increment of static microbubble signal was independent of microbubble concentration. It was deduced that the rate of increment of the static microbubble signal is primarily a function of the pulse frequency, whereas the maximum static microbubble signal intensity is dependent on three parameters: (a) the pulse frequency, (b) the flow velocity and (c) the microbubble concentration. The proposed dual frequency sequence may enable the application of radiation force for optimizing the effect of targeted imaging and modulating drug delivery in large blood vessels with high flow velocities.
Collapse
|
14
|
On the feasibility of imaging peripheral nerves using acoustic radiation force impulse imaging. ULTRASONIC IMAGING 2009; 31:172-82. [PMID: 19771960 PMCID: PMC2810513 DOI: 10.1177/016173460903100303] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Regional anesthesia is preferred over general anesthesia for many surgical procedures; however, challenges associated with poor image guidance limit its widespread acceptance as a viable alternative. In B-mode ultrasound images, the current standard for guidance, nerves can be difficult to visualize due to their similar acoustic impedance with surrounding tissues and needles must be aligned within the imaging plane at limited angles of approach that can impede successful peripheral nerve anesthesia. These challenges lead to inadequate regional anesthesia, necessitating intraoperative interventions, and can cause complications, including hemorrhage, intraneural injections and even nerve paralysis. ARFI imaging utilizes acoustic radiation force to generate images that portray relative tissue stiffness differences. Peripheral nerves are typically surrounded by many different tissue types (e.g., muscle, fat and fascia) that provide a mechanical basis for improved image contrast using ARFI imaging over conventional B-mode images. ARFI images of peripheral nerves and needles have been generated in cadaveric specimens and in humans in vivo. Contrast improvements of >600% have been achieved for distal sciatic nerve structures. The brachial plexus has been visualized with improved contrast over B-mode images in vivo during saline injection and ARFI images can delineate nerve bundle substructures to aid injection guidance. Physiologic motion during ARFI imaging of nerves near arterial structures has been successfully suppressed using ECG-triggered image acquisition and motion filters. This work demonstrates the feasibility of using ARFI imaging to improve the visualization of peripheral nerves during regional anesthesia procedures.
Collapse
|
15
|
Acoustic radiation force impulse imaging for noninvasive characterization of carotid artery atherosclerotic plaques: a feasibility study. ULTRASOUND IN MEDICINE & BIOLOGY 2009; 35:707-16. [PMID: 19243877 PMCID: PMC2813205 DOI: 10.1016/j.ultrasmedbio.2008.11.001] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2008] [Revised: 10/30/2008] [Accepted: 11/06/2008] [Indexed: 05/03/2023]
Abstract
Atherosclerotic disease in the carotid artery is a risk factor for stroke. The susceptibility of atherosclerotic plaque to rupture, however, is challenging to determine by any imaging method. In this study, acoustic radiation force impulse (ARFI) imaging is applied to atherosclerotic disease in the carotid artery to determine the feasibility of using ARFI to noninvasively characterize carotid plaques. ARFI imaging is a useful method for characterizing the local mechanical properties of tissue and is complementary to B-mode imaging. ARFI imaging can readily distinguish between stiff and soft regions of tissue. High-resolution images of both homogeneous and heterogeneous plaques were observed. Homogeneous plaques were indistinguishable in stiffness from vascular tissue. However, they showed thicknesses much greater than normal vascular tissue. In heterogeneous plaques, large and small soft regions were observed, with the smallest observed soft region having a diameter of 0.5 mm. A stiff cap was observed covering the large soft tissue region, with the cap thickness ranging from 0.7-1.3 mm.
Collapse
|
16
|
Pulsed high intensity focused ultrasound mediated nanoparticle delivery: mechanisms and efficacy in murine muscle. ULTRASOUND IN MEDICINE & BIOLOGY 2009; 35:416-24. [PMID: 19081668 PMCID: PMC2668521 DOI: 10.1016/j.ultrasmedbio.2008.09.021] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2008] [Revised: 08/05/2008] [Accepted: 09/19/2008] [Indexed: 05/09/2023]
Abstract
High intensity focused ultrasound (HIFU) is generally thought to interact with biological tissues in two ways: hyperthermia (heat) and acoustic cavitation. Pulsed mode HIFU has recently been demonstrated to increase the efficacy of a variety of drug therapies. Generally, it is presumed that the treatment acts to temporarily increase the permeability of the tissue to the therapeutic agent, however, the precise mechanism remains in dispute. In this article, we present evidence precluding hyperthermia as a principal mechanism for enhancing delivery, using a quantitative analysis of systemically administered fluorescent nanoparticles delivered to muscle in the calves of mice. Comparisons were carried out on the degree of enhancement between an equivalent heat treatment, delivered without ultrasound, and that of the pulsed-HIFU itself. In the murine calf muscle, Pulsed-HIFU treatment resulted in a significant increase in distribution of 200 nm particles (p < 0.016, n = 6), while the equivalent thermal dose showed no significant increase. Additional studies using this tissue/agent model also demonstrated that the pulsed HIFU enhancing effects persist for more than 24 h, which is longer than that of hyperthermia and acoustic cavitation, and offers the possibility of a novel third mechanism for mediating delivery.
Collapse
|
17
|
In vivo monitoring of focused ultrasound surgery using local harmonic motion. ULTRASOUND IN MEDICINE & BIOLOGY 2009; 35:65-78. [PMID: 18805626 PMCID: PMC2628756 DOI: 10.1016/j.ultrasmedbio.2008.07.001] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2007] [Revised: 06/11/2008] [Accepted: 07/15/2008] [Indexed: 05/10/2023]
Abstract
The present study established the feasibility of a technique for monitoring focused ultrasound (FUS) lesion formation in vivo using localized harmonic motion (LHM) measurements. Oscillatory motion (frequencies between 50 and 300 Hz) was generated within tissues by induction of a periodic radiation force with a FUS transducer. The harmonic motion was estimated using cross correlation of RF ultrasonic signals acquired at different instances during the motion by using a confocal diagnostic ultrasound transducer. The technique was evaluated in vivo in rabbit muscle (14 locations) in an magnetic resonance (MR) imager for simultaneous ultrasound harmonic motion tracking and MR thermometry. The measured maximum amplitude of the induced harmonic motion before and after the lesion formation was significantly different for all the tested motion frequencies, and decreased between 17 and 81% depending on the frequency and location. During the FUS exposure a drop in the maximum amplitude value was observed and a threshold value could be associated to the formation of a thermal lesion. A series of controlled sonications was performed by stopping the exposure when the threshold value in LHM amplitude was reached and the presence of a thermal lesion was confirmed by MR imaging. LHM measurements were also used to perform a spatial scan of the tissues across the exposure region and the thermal lesions could be detected as a reduction in the maximum motion amplitude value at the sonication region.
Collapse
|
18
|
Image features in medical vibro-acoustography: in vitro and in vivo results. ULTRASONICS 2008; 48:559-62. [PMID: 18599102 PMCID: PMC2651638 DOI: 10.1016/j.ultras.2008.04.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2008] [Revised: 04/23/2008] [Accepted: 04/25/2008] [Indexed: 05/20/2023]
Abstract
Vibro-acoustography is an imaging method based on audio-frequency harmonic vibrations induced in the object by the radiation force of focused ultrasound. The purpose of this study is to investigate features of vibro-acoustography images and manifestation of various tissue structures and calcifications in such images. Our motivation for this study is to pave the way for further in vitro and in vivo applications of vibro-acoustography. Here, vibro-acoustography images of excised prostate and in vivo breast are presented and compared with images obtained with other modalities. Resulting vibro-acoustography images obtained with a 3 MHz ultrasound transducer and at a vibration frequency of 50-60 kHz show soft tissue structures, tissue borders, and microcalcifications with high contrast, high resolution, and no speckle. It is concluded that vibro-acoustography offers features that may be valuable for diagnostic purposes.
Collapse
|
19
|
Quantifying hepatic shear modulus in vivo using acoustic radiation force. ULTRASOUND IN MEDICINE & BIOLOGY 2008; 34:546-58. [PMID: 18222031 PMCID: PMC2362504 DOI: 10.1016/j.ultrasmedbio.2007.10.009] [Citation(s) in RCA: 410] [Impact Index Per Article: 25.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2007] [Revised: 09/09/2007] [Accepted: 10/12/2007] [Indexed: 05/02/2023]
Abstract
The speed at which shear waves propagate in tissue can be used to quantify the shear modulus of the tissue. As many groups have shown, shear waves can be generated within tissues using focused, impulsive, acoustic radiation force excitations, and the resulting displacement response can be ultrasonically tracked through time. The goals of the work herein are twofold: (i) to develop and validate an algorithm to quantify shear wave speed from radiation force-induced, ultrasonically-detected displacement data that is robust in the presence of poor displacement signal-to-noise ratio and (ii) to apply this algorithm to in vivo datasets acquired in human volunteers to demonstrate the clinical feasibility of using this method to quantify the shear modulus of liver tissue in longitudinal studies. The ultimate clinical application of this work is noninvasive quantification of liver stiffness in the setting of fibrosis and steatosis. In the proposed algorithm, time-to-peak displacement data in response to impulsive acoustic radiation force outside the region of excitation are used to characterize the shear wave speed of a material, which is used to reconstruct the material's shear modulus. The algorithm is developed and validated using finite element method simulations. By using this algorithm on simulated displacement fields, reconstructions for materials with shear moduli (mu) ranging from 1.3-5 kPa are accurate to within 0.3 kPa, whereas stiffer shear moduli ranging from 10-16 kPa are accurate to within 1.0 kPa. Ultrasonically tracking the displacement data, which introduces jitter in the displacement estimates, does not impede the use of this algorithm to reconstruct accurate shear moduli. By using in vivo data acquired intercostally in 20 volunteers with body mass indices ranging from normal to obese, liver shear moduli have been reconstructed between 0.9 and 3.0 kPa, with an average precision of +/-0.4 kPa. These reconstructed liver moduli are consistent with those reported in the literature (mu = 0.75-2.5 kPa) with a similar precision (+/-0.3 kPa). Repeated intercostal liver shear modulus reconstructions were performed on nine different days in two volunteers over a 105-day period, yielding an average shear modulus of 1.9 +/- 0.50 kPa (1.3-2.5 kPa) in the first volunteer and 1.8 +/- 0.4 kPa (1.1-3.0 kPa) in the second volunteer. The simulation and in vivo data to date demonstrate that this method is capable of generating accurate and repeatable liver stiffness measurements and appears promising as a clinical tool for quantifying liver stiffness.
Collapse
|
20
|
Frame rate considerations for real-time abdominal acoustic radiation force impulse imaging. ULTRASONIC IMAGING 2006; 28:193-210. [PMID: 17521042 PMCID: PMC2254189 DOI: 10.1177/016173460602800401] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
With the advent of real-time Acoustic Radiation Force Impulse (ARFI) imaging, elevated frame rates are both desirable and relevant from a clinical perspective. However, fundamental limitations on frame rates are imposed by thermal safety concerns related to incident radiation force pulses. Abdominal ARFI imaging utilizes a curvilinear scanning geometry that results in markedly different tissue heating patterns than those previously studied for linear arrays or mechanically-translated concave transducers. Finite Element Method (FEM) models were used to simulate these tissue heating patterns and to analyze the impact of tissue heating on frame rates available for abdominal ARFI imaging. A perfusion model was implemented to account for cooling effects due to blood flow and frame rate limitations were evaluated in the presence of normal, reduced and negligible tissue perfusions. Conventional ARFI acquisition techniques were also compared to ARFI imaging with parallel receive tracking in terms of thermal efficiency. Additionally, thermocouple measurements of transducer face temperature increases were acquired to assess the frame rate limitations imposed by cumulative heating of the imaging array. Frame rates sufficient for many abdominal imaging applications were found to be safely achievable utilizing available ARFI imaging techniques.
Collapse
|
21
|
Application of ultrasound to selectively localize nanodroplets for targeted imaging and therapy. Mol Imaging 2006; 5:160-74. [PMID: 16954031 PMCID: PMC1752274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/11/2023] Open
Abstract
Lipid-coated perfluorocarbon nanodroplets are submicrometer-diameter liquid-filled droplets with proposed applications in molecularly targeted therapeutics and ultrasound (US) imaging. Ultrasonic molecular imaging is unique in that the optimal application of these agents depends not only on the surface chemistry, but also on the applied US field, which can increase receptor-ligand binding and membrane fusion. Theory and experiments are combined to demonstrate the displacement of perfluorocarbon nanoparticles in the direction of US propagation, where a traveling US wave with a peak pressure on the order of megapascals and frequency in the megahertz range produces a particle translational velocity that is proportional to acoustic intensity and increases with increasing center frequency. Within a vessel with a diameter on the order of hundreds of micrometers or larger, particle velocity on the order of hundreds of micrometers per second is produced and the dominant mechanism for droplet displacement is shown to be bulk fluid streaming. A model for radiation force displacement of particles is developed and demonstrates that effective particle displacement should be feasible in the microvasculature. In a flowing system, acoustic manipulation of targeted droplets increases droplet retention. Additionally, we demonstrate the feasibility of US-enhanced particle internalization and therapeutic delivery.
Collapse
|