1
|
Microbial Primer: The bacterial flagellum - how bacteria swim. MICROBIOLOGY (READING, ENGLAND) 2024; 170:001406. [PMID: 38226962 PMCID: PMC10866024 DOI: 10.1099/mic.0.001406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 10/11/2023] [Indexed: 01/17/2024]
Abstract
Bacteria swim using membrane-spanning, electrochemical gradient-powered motors that rotate semi-rigid helical filaments. This primer provides a brief overview of the basic synthesis, structure and operation of these nanomachines. Details and variations on the basic system can be found in suggested further reading.
Collapse
|
2
|
Association with the nonparoxysmal atrial fibrillation duration and outcome of ExTRa Mapping-guided rotor ablation. J Arrhythm 2023; 39:531-538. [PMID: 37560288 PMCID: PMC10407168 DOI: 10.1002/joa3.12897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2022] [Revised: 06/21/2023] [Accepted: 06/25/2023] [Indexed: 08/11/2023] Open
Abstract
Background Additional ablation strategies after pulmonary vein isolation (PVI) for patients with nonparoxysmal atrial fibrillation (non-PAF) lasting ≥2 years have not been fully effective. This is presumably because of insufficient identification of non-PAF maintenance mechanisms. In this study, we employed a novel online and real-time phase mapping system, ExTRa Mapping, to identify and modulate rotors as one of the non-PAF maintenance mechanisms in patients with non-PAF sustained after PVI. We investigated the relationship between outcomes of ExTRa Mapping-guided rotor ablation (ExTRa-ABL) and non-PAF duration prior to this procedure. Methods This study consisted of 73 non-PAF patients (63 ± 8 years, non-PAF duration 31 ± 37 months) who underwent the first ExTRa-ABL in patients with non-PAF sustained after completion of PVI. Results Freedom from non-PAF/atrial tachycardia (AT) recurrence at 12 months after ExTRa-ABL was achieved in 50 (69%) of patients. The non-PAF duration prior to ExTRa-ABL was significantly longer in patients with non-PAF/AT recurrence after ExTRa-ABL compared with those without (56 ± 50 vs. 19 ± 22 months, p = .001). In patients with non-PAF duration of ≤60 months prior to ExTRa-ABL, compared with >60 months, non-PAF/AT-free rate was significantly higher (68.9% vs. 23.1%, p < .001), during the follow-up of 36 ± 18 months. Conclusions A non-PAF duration of ≤60 months prior to ExTRa-ABL was associated with a better outcome. The effect of ExTRa-ABL was considered to be limited in patients with >60 months of non-PAF duration.
Collapse
|
3
|
Ring formation by Vibrio fusion protein composed of FliF and FliG, MS-ring and C-ring component of bacterial flagellar motor in membrane. Biophys Physicobiol 2023; 20:e200028. [PMID: 38496245 PMCID: PMC10941966 DOI: 10.2142/biophysico.bppb-v20.0028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 06/05/2023] [Indexed: 03/19/2024] Open
Abstract
The marine bacterium Vibrio alginolyticus has a single flagellum as a locomotory organ at the cell pole, which is rotated by the Na+-motive force to swim in a liquid. The base of the flagella has a motor composed of a stator and rotor, which serves as a power engine to generate torque through the rotor-stator interaction coupled to Na+ influx through the stator channel. The MS-ring, which is embedded in the membrane at the base of the flagella as part of the rotor, is the initial structure required for flagellum assembly. It comprises 34 molecules of the two-transmembrane protein FliF. FliG, FliM, and FliN form a C-ring just below the MS-ring. FliG is an important rotor protein that interacts with the stator PomA and directly contributes to force generation. We previously found that FliG promotes MS-ring formation in E. coli. In the present study, we constructed a fliF-fliG fusion gene, which encodes an approximately 100 kDa protein, and the successful production of this protein effectively formed the MS-ring in E. coli cells. We observed fuzzy structures around the ring using either electron microscopy or high-speed atomic force microscopy (HS-AFM), suggesting that FliM and FliN are necessary for the formation of a stable ring structure. The HS-AFM movies revealed flexible movements at the FliG region.
Collapse
|
4
|
The spatiotemporal electrogram dispersion ablation targeting rotors is more effective for elderly patients than non-elderly population. J Arrhythm 2023; 39:315-326. [PMID: 37324760 PMCID: PMC10264740 DOI: 10.1002/joa3.12860] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 04/10/2023] [Accepted: 04/16/2023] [Indexed: 06/17/2023] Open
Abstract
Background Modulating atrial fibrillation (AF) drivers has been proposed as one of the effective ablation strategies for non-paroxysmal AF (non-PAF). However, the optimal non-PAF ablation strategy is still under debate because the exact mechanisms of AF persistence including focal activity and/or rotational activity, are not well-understood. Recently, spatiotemporal electrogram dispersion (STED) assumed to indicate rotors in the form of rotational activity is proposed as an effective target for non-PAF ablation. We aimed to clarify the effectiveness of STED ablation for modulating AF drivers. Methods STED ablation plus pulmonary vein isolation was applied in 161 consecutive non-PAF patients not undergoing previous ablation. STED areas within the entire left and right atria were identified and ablated during AF. After the procedures, the STED ablation's acute and long-term outcomes were investigated. Results (1) Despite a more effective acute outcome of the STED ablation for both AF termination and non-inducibility of atrial tachyarrhythmias (ATAs), Kaplan-Meier curves showed that the 24-month freedom ratio from ATAs was 49%, which resulted from the higher recurrence ratio of atrial tachycardia (AT) rather than AF. (2) A multivariate analysis showed that the determinant of ATA recurrences was only a non-elderly age, not long-standing persistent AF, and an enlarged left atrium, which were conventionally considered as key factors. Conclusions STED ablation targeting rotors was effective in elderly non-PAF patients. Therefore, the main mechanism of AF persistency and the component of the fibrillatory conduction might vary between elders and non-elders. However, we should be careful about post-ablation ATs following substrate modification.
Collapse
|
5
|
Research on Attitude Detection and Flight Experiment of Coaxial Twin- Rotor UAV. SENSORS (BASEL, SWITZERLAND) 2022; 22:9572. [PMID: 36559940 PMCID: PMC9785774 DOI: 10.3390/s22249572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 11/28/2022] [Accepted: 11/30/2022] [Indexed: 06/17/2023]
Abstract
Aiming at the problem that the single sensor of the coaxial UAV cannot accurately measure attitude information, a pose estimation algorithm based on unscented Kalman filter information fusion is proposed. The kinematics and dynamics characteristics of coaxial folding twin-rotor UAV are studied, and a mathematical model is established. The common attitude estimation methods are analyzed, and the extended Kalman filter algorithm and unscented Kalman filter algorithm are established. In order to complete the test of the prototype of a small coaxial twin-rotor UAV, a test platform for the dynamic performance and attitude angle of the semi-physical flight of the UAV was established. The platform can analyze the mechanical vibration, attitude angle and noise of the aircraft. It can also test and analyze the characteristics of the mechanical vibration and noise produced by the UAV at different rotor speeds. Furthermore, the static and time-varying trends of the pitch angle and yaw angle of the Kalman filter attitude estimation algorithm is further analyzed through static and dynamic experiments. The analysis results show that the attitude estimation of the UKF is better than that of the EKF when the throttle is between 0.2σ and 0.9σ. The error of the algorithm is less than 0.6°. The experiment and analysis provide a reference for the optimization of the control parameters and flight control strategy of the coaxial folding dual-rotor aircraft.
Collapse
|
6
|
An Evaluation of Phase Analysis to Interpret Atrial Activation Patterns during Persistent Atrial Fibrillation for Targeted Ablation. J Clin Med 2022; 11:jcm11195807. [PMID: 36233675 PMCID: PMC9572396 DOI: 10.3390/jcm11195807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 09/21/2022] [Accepted: 09/29/2022] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Phase analysis has been used to identify and localize atrial fibrillation (AF) sources for targeted ablation. We previously demonstrated that repetitive wannabe reentry (incomplete reentry) often generated an apparent stable rotor using phase analysis. The misinterpretation caused by phase analysis using atrial electrograms (AEGs) may result from detecting inaccurate time points at phase inversion (π to -π) in the instantaneous phase waveform converted from AEG. The purpose of this study was to evaluate the accuracy of phase analysis to detect atrial activations recorded from the high-density mapping of AF in patients with persistent and long-standing persistent (LSP) AF. METHODS AND RESULTS During open heart surgery, we recorded activation from both atria simultaneously using 512 electrodes in 7 patients with persistent and LSP AF. The phase analysis was compared to manual measurements during 4 s of data. For the accuracy of activation sequence maps, a successful recording site was defined as having ≤4 mismatched activation times during the 4 s. In all AF episodes, the accuracy of the phase analysis was only 82% of the total number of activation times due to either activation time differences (14.7%), under-sensing (2.7%), or over-sensing (0.6%). Only 67.9% of the total recording sites met the requirement of a successful recording site by phase analysis. In unsuccessful recording sites, AEG characteristics were relatively irregular cycle length (CL), complex AEG, and double potential AEG. CONCLUSION The phase analysis was less accurate in recording sites with a relatively irregular CL, complex AEG, or double potential AEG. As a result, phase analysis may lead to the misinterpretation of atrial activation patterns during AF. A visual review of the original AEG is needed to confirm the detected AF sources of phase analysis before performing targeted ablation.
Collapse
|
7
|
Formation of multiple flagella caused by a mutation of the flagellar rotor protein FliM in Vibrio alginolyticus. Genes Cells 2022; 27:568-578. [PMID: 35842835 DOI: 10.1111/gtc.12975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 06/21/2022] [Accepted: 07/11/2022] [Indexed: 11/30/2022]
Abstract
Marine bacterium Vibrio alginolyticus forms a single flagellum at a cell pole. In Vibrio, two proteins (GTPase FlhF and ATPase FlhG) regulate the number of flagella. We previously isolated the NMB155 mutant that forms multiple flagella despite the absence of mutations in flhF and flhG. Whole-genome sequencing of NMB155 identified an E9K mutation in FliM that is a component of C-ring in the flagellar rotor. Mutations in FliM result in defects in flagellar formation (fla) and flagellar rotation (che or mot); however, there are a few reports indicating that FliM mutations increase the number of flagella. Here, we determined that the E9K mutation confers the multi-flagellar phenotype and also the che phenotype. The co-expression of wild-type FliM and FliM-E9K indicated that they were competitive in regard to determining the flagellar number. The ATPase activity of FlhG has been correlated with the number of flagella. We observed that the ATPase activity of FlhG was increased by the addition of FliM but not by the addition of FliM-E9K in vitro. This indicates that FliM interacts with FlhG to increase its ATPase activity, and the E9K mutation may inhibit this interaction. FliM may control the ATPase activity of FlhG to properly regulate the number of the polar flagellum at the cell pole. This article is protected by copyright. All rights reserved.
Collapse
|
8
|
Stabilization of unstable reentrant atrial tachycardias via fractionated continuous electrical activity ablation (CHAOS study). Cardiol J 2022; 30:799-809. [PMID: 35578756 PMCID: PMC10635713 DOI: 10.5603/cj.a2022.0036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 11/11/2021] [Accepted: 11/19/2021] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Unstable reentrant atrial tachycardias (ATs) (i.e., those with frequent circuit modification or conversion to atrial fibrillation) are challenging to ablate. We tested a strategy to achieve arrhythmia stabilization into mappable stable ATs based on the detection and ablation of rotors. METHODS All consecutive patients from May 2017 to December 2019 were included. Mapping was performed using conventional high-density mapping catheters (IntellaMap ORION, PentaRay NAV, or Advisor HD Grid). Rotors were subjectively identified as fractionated continuous (or quasi-continuous) electrograms on 1-2 adjacent bipoles, without dedicated software. In patients without detectable rotors, sites with spatiotemporal dispersion (i.e., all the cycle length comprised within the mapping catheter) plus non-continuous fractionation on single bipoles were targeted. Ablation success was defined as conversion to a stable AT or sinus rhythm. RESULTS Ninety-seven patients with reentrant ATs were ablated. Of these, 18 (18.6%) presented unstable circuits. Thirteen (72%) patients had detectable rotors (median 2 [1-3] rotors per patient); focal ablation was successful in 12 (92%). In the other 5 patients, 17 sites with spatiotemporal dispersion were identified and targeted. Globally, and excluding 1 patient with spontaneous AT stabilization, ablation success was achieved in 16/17 patients (94.1%). One-year freedom from atrial arrhythmias was similar between patients with unstable and stable ATs (66.7% vs. 65.8%, p = 0.946). CONCLUSIONS Most unstable reentrant ATs show detectable rotors, identified as sites with single-bipole fractionated quasi-continuous signals, or spatiotemporal dispersion plus non-continuous fractionation. Ablation of these sites is highly effective to stabilize the AT or convert it into sinus rhythm.
Collapse
|
9
|
The Improvement of Performance through Minimizing Scallop Size in MEMS Based Micro Wind Turbine. MICROMACHINES 2021; 12:mi12101261. [PMID: 34683313 PMCID: PMC8537036 DOI: 10.3390/mi12101261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 10/13/2021] [Accepted: 10/15/2021] [Indexed: 11/16/2022]
Abstract
In this paper we report on the improvement of performance by minimizing scallop size through deep reactive-ion etching (DRIE) of rotors in micro-wind turbines based on micro-electro-mechanical systems (MEMS) technology. The surface profile of an MEMS rotor can be controlled by modifying the scallop size of the DRIE surface through changing the process recipe. The fabrication of a planar disk-type MEMS rotor through the MEMS fabrication process was carried out, and for the comparison of the improvements in the performance of each rotor, RPM testing and open circuit output voltage experiments of stators and permanent magnets were performed. We found that the smooth etching profile with a minimized scallop size formed using DRIE results in improved rotation properties in MEMS-based wind turbine rotors.
Collapse
|
10
|
Site-directed crosslinking identifies the stator- rotor interaction surfaces in a hybrid bacterial flagellar motor. J Bacteriol 2021; 203:JB.00016-21. [PMID: 33619152 PMCID: PMC8092157 DOI: 10.1128/jb.00016-21] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
The bacterial flagellum is the motility organelle powered by a rotary motor. The rotor and stator elements of the motor are located in the cytoplasmic membrane and cytoplasm. The stator units assemble around the rotor, and an ion flux (typically H+ or Na+) conducted through a channel of the stator induces conformational changes that generate rotor torque. Electrostatic interactions between the stator protein PomA in Vibrio (MotA in Escherichia coli) and the rotor protein FliG have been shown by genetic analyses, but have not been demonstrated biochemically. Here, we used site-directed photo- and disulfide-crosslinking to provide direct evidence for the interaction. We introduced a UV-reactive amino acid, p-benzoyl-L-phenylalanine (pBPA), into the cytoplasmic region of PomA or the C-terminal region of FliG in intact cells. After UV irradiation, pBPA inserted at a number of positions in PomA formed a crosslink with FliG. PomA residue K89 gave the highest yield of crosslinks, suggesting that it is the PomA residue nearest to FliG. UV-induced crosslinking stopped motor rotation, and the isolated hook-basal body contained the crosslinked products. pBPA inserted to replace residues R281 or D288 in FliG formed crosslinks with the Escherichia coli stator protein, MotA. A cysteine residue introduced in place of PomA K89 formed disulfide crosslinks with cysteine inserted in place of FliG residues R281 and D288, and some other flanking positions. These results provide the first demonstration of direct physical interaction between specific residues in FliG and PomA/MotA.ImportanceThe bacterial flagellum is a unique organelle that functions as a rotary motor. The interaction between the stator and rotor is indispensable for stator assembly into the motor and the generation of motor torque. However, the interface of the stator-rotor interaction has only been defined by mutational analysis. Here, we detected the stator-rotor interaction using site-directed photo- and disulfide-crosslinking approaches. We identified several residues in the PomA stator, especially K89, that are in close proximity to the rotor. Moreover, we identified several pairs of stator and rotor residues that interact. This study directly demonstrates the nature of the stator-rotor interaction and suggests how stator units assemble around the rotor and generate torque in the bacterial flagellar motor.
Collapse
|
11
|
Two Distinct Conformations in 34 FliF Subunits Generate Three Different Symmetries within the Flagellar MS-Ring. mBio 2021; 12:e03199-20. [PMID: 33653894 PMCID: PMC8092281 DOI: 10.1128/mbio.03199-20] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 01/22/2021] [Indexed: 11/20/2022] Open
Abstract
The bacterial flagellum is a protein nanomachine essential for bacterial motility. The flagellar basal body contains several ring structures. The MS-ring is embedded in the cytoplasmic membrane and is formed at the earliest stage of flagellar formation to serve as the base for flagellar assembly as well as a housing for the flagellar protein export gate complex. The MS-ring is formed by FliF, which has two transmembrane helices and a large periplasmic region. A recent electron cryomicroscopy (cryoEM) study of the MS-ring formed by overexpressed FliF revealed a symmetry mismatch between the S-ring and inner part of the M-ring. However, the actual symmetry relation in the native MS-ring and positions of missing domains remain obscure. Here, we show the structure of the M-ring by combining cryoEM and X-ray crystallography. The crystal structure of the N-terminal half of the periplasmic region of FliF showed that it consists of two domains (D1 and D2) resembling PrgK D1/PrgH D2 and PrgK D2/PrgH D3 of the injectisome. CryoEM analysis revealed that the inner part of the M-ring shows a gear wheel-like density with the inner ring of C23 symmetry surrounded by cogs with C11 symmetry, to which 34 copies of FliFD1-D2 fitted well. We propose that FliFD1-D2 adopts two distinct orientations in the M-ring relative to the rest of FliF, with 23 chains forming the wheel and 11 chains forming the cogs, and the 34 chains come together to form the S-ring with C34 symmetry for multiple functions of the MS-ring.IMPORTANCE The bacterial flagellum is a motility organelle formed by tens of thousands of protein molecules. At the earliest stage of flagellar assembly, a transmembrane protein, FliF, forms the MS-ring in the cytoplasmic membrane as the base for flagellar assembly. Here, we solved the crystal structure of a FliF fragment. Electron cryomicroscopy (cryoEM) structural analysis of the MS-ring showed that the M-ring and S-ring have different rotational symmetries. By docking the crystal structure of the FliF fragment into the cryoEM density map of the entire MS-ring, we built a model of the whole periplasmic region of FliF and proposed that FliF adopts two distinct conformations to generate three distinct C11, C23, and C34 symmetries within the MS-ring for its multiple functions.
Collapse
|
12
|
Late-gadolinium enhancement properties associated with atrial fibrillation rotors in patients with persistent atrial fibrillation. J Cardiovasc Electrophysiol 2021; 32:1005-1013. [PMID: 33556994 DOI: 10.1111/jce.14933] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 01/12/2021] [Accepted: 01/21/2021] [Indexed: 01/08/2023]
Abstract
BACKGROUND A computational model demonstrated that atrial fibrillation (AF) rotors could be distributed in patchy late-gadolinium enhancement (LGE) areas and play an important role in AF drivers. However, this was not validated in humans. OBJECTIVE The purpose of this study was to evaluate the LGE properties of AF rotors in patients with persistent AF. METHODS A total of 287 segments in 15 patients with persistent AF (long-standing persistent AF in 9 patients) that underwent AF ablation were assessed. Non-passively activated areas (NPAs), where rotational activation (AF rotor) was frequently observed, were detected by the novel real-time phase mapping (ExTRa Mapping). The properties of the LGE areas were assessed using the LGE heterogeneity and the density which was evaluated by the entropy (LGE-entropy) and the volume ratio of the enhancement voxel (LGE-volume ratio), respectively. RESULTS NPAs were found in 61 (21%) of 287 segments and were mostly found around the pulmonary vein antrum. A receiver operating characteristic curve analysis yielded an optimal cutoff value of 5.7% and 10% for the LGE-entropy and LGE-volume ratio, respectively. The incidence of NPAs was significantly higher at segments with an LGE-entropy of >5.7 and LGE-volume ratio of >10% than at the other segments (38 [30%] of 126 vs. 23 [14%] of 161 segments; p = .001). No NPAs were found at segments with an LGE-volume ratio of >50% regardless of the LGE-entropy. Of five patients with AF recurrence, NPAs outside the PV antrum were not ablated in three patients and the remaining NPAs were ablated, but their LGE-entropy and LGE-volume ratio were low. CONCLUSION AF rotors are mostly distributed in relatively weak and much more heterogenous LGE areas.
Collapse
|
13
|
Multi-Parameter Measurement of Rotors Using the Doppler Effect of Frequency-Swept Interferometry. SENSORS (BASEL, SWITZERLAND) 2020; 20:s20247178. [PMID: 33333833 PMCID: PMC7765328 DOI: 10.3390/s20247178] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 12/09/2020] [Accepted: 12/14/2020] [Indexed: 06/12/2023]
Abstract
The Doppler effect of frequency-swept interferometry (FSI) is often seen as an obstacle to the dynamic ranging accuracy. However, the potential of this obstacle is rarely noticed and used. In this paper, by combining the periodical characteristics of the rotational Doppler effect, an FSI-based multi-parameter measurement method for the rotor is proposed. Through the establishment of the rotational Doppler formula of FSI, it is found that the frequency, direct component, and amplitude of the dynamic distance given by FSI can be utilized to estimate the angular velocity, axial clearance, and tilt angle of the rotor, respectively. A rotor platform and a fiber-optic FSI system were constructed, and a series of experiments were carried out to verify the proposed method. The experimental results showed that the relative errors of the measured axial clearance, angular velocity, and tilt angle were less than 3.5%. This work provides a new perspective on the multi-parameter measurement of the rotor and makes it possible to directly perform multi-parameter measurement inside the space-confined rotating machinery as only a single small-size fiber-optic probe is needed.
Collapse
|
14
|
Numerical Optimization Simulation of Synchronous Four-Wing Rotor. MATERIALS 2020; 13:ma13235353. [PMID: 33255845 PMCID: PMC7728321 DOI: 10.3390/ma13235353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 11/21/2020] [Accepted: 11/23/2020] [Indexed: 11/27/2022]
Abstract
The mixer is the most widely used batch mixing equipment in the rubber industry. The rotor is a core component and has a great impact on the mixing effect of the equipment. The current rotor structure design is done empirically, being tightly dependent on practical experience. This paper proposes a method for optimizing the rotor structure by using optimization algorithms combined with numerical simulation technology. Using MATLAB software, a parametric design program for synchronous rotors and a set of optimization programs for the particle swarm optimization (PSO) algorithm were written. The global distribution index was used as the fitness function to optimize the synchronous rotor configuration. A comparative analysis of the rotors before and after optimization shows that the optimization process is feasible, and the results are reliable. This provides new ideas for the design and development of mixer rotors.
Collapse
|
15
|
Standardizing Single-Frame Phase Singularity Identification Algorithms and Parameters in Phase Mapping During Human Atrial Fibrillation. Front Physiol 2020; 11:869. [PMID: 32792983 PMCID: PMC7386053 DOI: 10.3389/fphys.2020.00869] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Accepted: 06/29/2020] [Indexed: 12/03/2022] Open
Abstract
PURPOSE Recent investigations failed to reproduce the positive rotor-guided ablation outcomes shown by initial studies for treating persistent atrial fibrillation (persAF). Phase singularity (PS) is an important feature for AF driver detection, but algorithms for automated PS identification differ. We aim to investigate the performance of four different techniques for automated PS detection. METHODS 2048-channel virtual electrogram (VEGM) and electrocardiogram signals were collected for 30 s from 10 patients undergoing persAF ablation. QRST-subtraction was performed and VEGMs were processed using sinusoidal wavelet reconstruction. The phase was obtained using Hilbert transform. PSs were detected using four algorithms: (1) 2D image processing based and neighbor-indexing algorithm; (2) 3D neighbor-indexing algorithm; (3) 2D kernel convolutional algorithm estimating topological charge; (4) topological charge estimation on 3D mesh. PS annotations were compared using the structural similarity index (SSIM) and Pearson's correlation coefficient (CORR). Optimized parameters to improve detection accuracy were found for all four algorithms using F β score and 10-fold cross-validation compared with manual annotation. Local clustering with density-based spatial clustering of applications with noise (DBSCAN) was proposed to improve algorithms 3 and 4. RESULTS The PS density maps created by each algorithm with default parameters were poorly correlated. Phase gradient threshold and search radius (or kernels) were shown to affect PS detections. The processing times for the algorithms were significantly different (p < 0.0001). The F β scores for algorithms 1, 2, 3, 3 + DBSCAN, 4 and 4 + DBSCAN were 0.547, 0.645, 0.742, 0.828, 0.656, and 0.831. Algorithm 4 + DBSCAN achieved the best classification performance with acceptable processing time (2.0 ± 0.3 s). CONCLUSION AF driver identification is dependent on the PS detection algorithms and their parameters, which could explain some of the inconsistencies in rotor-guided ablation outcomes in different studies. For 3D triangulated meshes, algorithm 4 + DBSCAN with optimal parameters was the best solution for real-time, automated PS detection due to accuracy and speed. Similarly, algorithm 3 + DBSCAN with optimal parameters is preferred for uniform 2D meshes. Such algorithms - and parameters - should be preferred in future clinical studies for identifying AF drivers and minimizing methodological heterogeneities. This would facilitate comparisons in rotor-guided ablation outcomes in future works.
Collapse
|
16
|
Abstract
Due to its inherent out-of-equilibrium nature, active matter in confinement may exhibit collective behavior absent in unconfined systems. Extensive studies have indicated that hydrodynamic or steric interactions between active particles and boundary play an important role in the emergence of collective behavior. However, besides introducing external couplings at the single-particle level, the confinement also induces an inhomogeneous density distribution due to particle-position correlations, whose effect on collective behavior remains unclear. Here, we investigate this effect in a minimal chiral active matter composed of self-spinning rotors through simulation, experiment, and theory. We find that the density inhomogeneity leads to a position-dependent frictional stress that results from interrotor friction and couples the spin to the translation of the particles, which can then drive a striking spatially oscillating collective motion of the chiral active matter along the confinement boundary. Moreover, depending on the oscillation properties, the collective behavior has three different modes as the packing fraction varies. The structural origins of the transitions between the different modes are well identified by the percolation of solid-like regions or the occurrence of defect-induced particle rearrangement. Our results thus show that the confinement-induced inhomogeneity, dynamic structure, and compressibility have significant influences on collective behavior of active matter and should be properly taken into account.
Collapse
|
17
|
Abstract
Molecular rotors have attracted considerable interest for their prospects in nanotechnology. However, their adsorption on supporting substrates, where they may be addressed individually, usually modifies their properties. Here, we investigate the switching of two closely related three-state rotors mounted on platforms on Au(111) using low-temperature scanning tunneling microscopy and density functional theory calculations. Being physisorbed, the platforms retain important gas-phase properties of the rotor. This simplifies a detailed analysis and permits, for instance, the identification of the vibrational modes involved in the rotation process. The symmetry provided by the platform enables active control of the rotation direction through electrostatic interactions with the tip and charged neighboring adsorbates. The present investigation of two model systems may turn out useful for designing platforms that provide directional rotation and for transferring more sophisticated molecular machines from the gas phase to surfaces.
Collapse
|
18
|
Influence of Rotor Dynamic Scattering on Helicopter Radar Cross-Section. SENSORS 2020; 20:s20072097. [PMID: 32276513 PMCID: PMC7181235 DOI: 10.3390/s20072097] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Revised: 04/04/2020] [Accepted: 04/05/2020] [Indexed: 11/16/2022]
Abstract
With the continuous improvement and development of armed helicopters, the research on their stealth characteristics has become more and more in depth. In order to obtain the complex effect of stealth characteristics caused by the high-speed rotation of rotor-like components, a dynamic scattering method (DSM) is presented. Rotation speed, azimuth, elevation angle, pitching angle, and rolling angle are studied and discussed in detail. The results show that the electromagnetic scattering characteristics of the main rotor and tail rotor are dynamic and periodic. This period characteristic is related to the rotation speed and attitude angle of the rotor. The radar cross-section (RCS) of the helicopter varies greatly at different observation angles and attitude angles, but the dynamic electromagnetic scattering effect caused by the main rotor and tail rotor cannot be ignored. The presented DSM is effective and efficient for studying the dynamic RCS of the rotor-type parts of a helicopter or the whole machine.
Collapse
|
19
|
A New Fault Feature Extraction Method for Rotating Machinery Based on Multiple Sensors. SENSORS 2020; 20:s20061713. [PMID: 32204389 PMCID: PMC7146135 DOI: 10.3390/s20061713] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 03/10/2020] [Accepted: 03/18/2020] [Indexed: 11/16/2022]
Abstract
During the operation of rotating machinery, the vibration signals measured by sensors are the aliasing signals of various vibration sources, and they contain strong noises. Conventional signal processing methods have difficulty separating the aliasing signals, which causes great difficulties in the condition monitoring and fault diagnosis of the equipment. The principle and method of blind source separation are introduced, and it is pointed out that the blind source separation algorithm is invalid in strong pulse noise environments. In these environments, the vibration signals are first de-noised with the median filter (MF) method and the de-noised signals are separated with an improved joint approximate diagonalization of eigenmatrices (JADE) algorithm. The simulation results found here verify the effectiveness of the proposed method. Finally, the vibration signal of the hybrid rotor is effectively separated by the proposed method. A new separation approach is thus provided for vibration signals in strong pulse noise environments.
Collapse
|
20
|
An atrial fibrillation rotor, mapped conventionally. J Cardiovasc Electrophysiol 2020; 31:544-546. [PMID: 31908076 PMCID: PMC9292734 DOI: 10.1111/jce.14329] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2019] [Revised: 12/12/2019] [Accepted: 12/13/2019] [Indexed: 12/01/2022]
Abstract
This case illustrates that the condition of atrial fibrillation (AF) may harbor site(s) of regular rotational activity, reentry may be an underlying mechanism, high periodicity and wavebreak through areas of the scar may generate fibrillatory conduction, and disintegration of the “rotor” may not abolish AF.
Collapse
|
21
|
A Novel Mapping System for Panoramic Mapping of the Left Atrium: Application to Detect and Characterize Localized Sources Maintaining Atrial Fibrillation. JACC Clin Electrophysiol 2019; 4:124-134. [PMID: 29387810 PMCID: PMC5777816 DOI: 10.1016/j.jacep.2017.09.177] [Citation(s) in RCA: 68] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
Objectives This study sought to use a novel panoramic mapping system (CARTOFINDER) to detect and characterize drivers in persistent atrial fibrillation (AF). Background Mechanisms sustaining persistent AF remain uncertain. Methods Patients undergoing catheter ablation for persistent AF were included. A 64-pole basket catheter was used to acquire unipolar signals, which were processed by the mapping system to generate wavefront propagation maps. The system was used to identify and characterize potential drivers in AF pre- and post-pulmonary vein (PV) isolation. The effect of ablation on drivers identified post-PV isolation was assessed. Results Twenty patients were included in the study with 112 CARTOFINDER maps created. Potential drivers were mapped in 19 of 20 patients with AF (damage to the basket and noise on electrograms was present in 1 patient). Thirty potential drivers were identified all of which were transient but repetitive; 19 were rotational and 11 focal. Twenty-six drivers were ablated with a predefined response in 22 of 26 drivers: AF terminated with 12 and cycle length slowed (≥30 ms) with 10. Drivers with rotational activation were predominantly mapped to sites of low-voltage zones (81.8%). PV isolation had no remarkable impact on the cycle length at the driver sites (138.4 ± 14.3 ms pre-PV isolation vs. 137.2 ± 15.2 ms post-PV isolation) and drivers that had also been identified on pre-PV isolation maps were more commonly associated with AF termination. Conclusions Drivers were identified in almost all patients in the form of intermittent but repetitive focal or rotational activation patterns. The mechanistic importance of these phenomena was confirmed by the response to ablation.
Collapse
|
22
|
Rotors Detected by Phase Analysis of Filtered, Epicardial Atrial Fibrillation Electrograms Colocalize With Regions of Conduction Block. Circ Arrhythm Electrophysiol 2019; 11:e005858. [PMID: 30354409 PMCID: PMC6553551 DOI: 10.1161/circep.117.005858] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Several recent studies suggest rotors detected by phase mapping may act as main drivers of persistent atrial fibrillation. However, the electrophysiological nature of detected rotors remains unclear. We performed a direct, 1:1 comparison between phase and activation time mapping in high-density, epicardial, direct-contact mapping files of human atrial fibrillation. METHODS Thirty-eight unipolar electrogram files of 10 s duration were recorded in patients with atrial fibrillation (n=20 patients) using a 16×16 electrode array placed on the epicardial surface of the left atrial posterior wall or the right atrial free wall. Phase maps and isochrone wave maps were constructed for all recordings. For each detected phase singularity (PS) with a lifespan of >1 cycle length, the corresponding conduction pattern was investigated in the isochrone wave maps. RESULTS When using sinusoidal recomposition and Hilbert Transform, 138 PSs were detected. One hundred and four out of 138 PSs were detected within 1 electrode distance (1.5 mm) from a line of conduction block between nonrotating wavefronts detected by activation mapping. Far fewer rotating wavefronts were detected when rotating activity was identified based on wave mapping (18 out of 8219 detected waves). Fourteen out of these 18 cases were detected as PSs in phase mapping. Phase analysis of filtered electrograms produced by simulated wavefronts separated by conduction block also identified PSs on the line of conduction block. CONCLUSIONS PSs identified by phase analysis of filtered epicardial electrograms colocalize with conduction block lines identified by activation mapping. Detection of PSs using phase analysis has a low specificity for identifying rotating wavefronts during human atrial fibrillation using activation mapping.
Collapse
|
23
|
Instantaneous Amplitude and Frequency Modulations Detect the Footprint of Rotational Activity and Reveal Stable Driver Regions as Targets for Persistent Atrial Fibrillation Ablation. Circ Res 2019; 125:609-627. [PMID: 31366278 PMCID: PMC6735936 DOI: 10.1161/circresaha.119.314930] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
RATIONALE Costly proprietary panoramic multielectrode (64-256) acquisition systems are being increasingly used together with conventional electroanatomical mapping systems for persistent atrial fibrillation (PersAF) ablation. However, such approaches target alleged drivers (rotational/focal) regardless of their activation frequency dynamics. OBJECTIVES To test the hypothesis that stable regions of higher than surrounding instantaneous frequency modulation (iFM) drive PersAF and determine whether rotational activity is specific for such regions. METHODS AND RESULTS First, novel single-signal algorithms based on instantaneous amplitude modulation (iAM) and iFM to detect rotational-footprints without panoramic multielectrode acquisition systems were tested in 125 optical movies from 5 ex vivo Langendorff-perfused PersAF sheep hearts (sensitivity/specificity, 92.6/97.5%; accuracy, 2.5-mm) and in computer simulations. Then, 16 pigs underwent high-rate atrial pacing to develop PersAF. After a median (interquartile range [IQR]) of 4.4 (IQR, 2.5-9.9) months of high-rate atrial pacing followed by 4.1 (IQR, 2.7-5.4) months of self-sustained PersAF, pigs underwent in vivo high-density electroanatomical atrial mapping (4920 [IQR, 4435-5855] 8-second unipolar signals per map). The first 4 out of 16 pigs were used to adapt ex vivo optical proccessing of iFM/iAM to in vivo electrical signals. In the remaining 12 out of 16 pigs, regions of higher than surrounding average iFM were considered leading-drivers. Two leading-driver + rotational-footprint maps were generated 2.6 (IQR, 2.4-2.9) hours apart to test leading-driver spatiotemporal stability and guide ablation. Leading-driver regions (2.5 [IQR, 2.0-4.0] regions/map) exactly colocalized (95.7%) in the 2 maps, and their ablation terminated PersAF in 92.3% of procedures (radiofrequency until termination, 16.9 [IQR, 9.2-35.8] minutes; until nonsustainability, 20.4 [IQR, 12.8-44.0] minutes). Rotational-footprints were found at every leading-driver region, albeit most (76.8% [IQR, 70.5%-83.6%]) were located outside. Finally, the translational ability of this approach was tested in 3 PersAF redo patients. CONCLUSIONS Both rotational-footprints and spatiotemporally stable leading-driver regions can be located using iFM/iAM algorithms without panoramic multielectrode acquisition systems. In pigs, ablation of leading-driver regions usually terminates PersAF and prevents its sustainability. Rotational activations are sensitive but not specific to such regions. Single-signal iFM/iAM algorithms could be integrated into conventional electroanatomical mapping systems to improve driver detection accuracy and reduce the cost of patient-tailored/mechanistic approaches.
Collapse
|
24
|
Design and Testing of a Co-Rotating Vibration Excitation System. SENSORS 2018; 19:s19010092. [PMID: 30597873 PMCID: PMC6338975 DOI: 10.3390/s19010092] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Revised: 12/23/2018] [Accepted: 12/24/2018] [Indexed: 12/03/2022]
Abstract
A vibration excitation system (VES) in a form of an active coupling is proposed, designed and manufactured. The system is equipped with a set of piezoelectric stack actuators uniformly distributed around the rotor axis and positioned parallel to each other. The actuator arrangement allows an axial displacement of the coupling halves as well as their rotation about any transverse axis. Through the application of the VES an aimed vibration excitation is realised in a co-rotating coordinate system, which enables a non-invasive and precise modal analysis of rotating components. As an example, the VES is applied for the characterisation of the structural dynamic behaviour of a generic steel rotor at different rotational speeds. The first results are promising for both stationary and rotating conditions.
Collapse
|
25
|
Rotor Fault Diagnosis Based on Characteristic Frequency Band Energy Entropy and Support Vector Machine. ENTROPY 2018; 20:e20120932. [PMID: 33266656 PMCID: PMC7512519 DOI: 10.3390/e20120932] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Revised: 12/02/2018] [Accepted: 12/05/2018] [Indexed: 11/17/2022]
Abstract
Rotor is a widely used and easily defected mechanical component. Thus, it is significant to develop effective techniques for rotor fault diagnosis. Fault signature extraction and state classification of the extracted signatures are two key steps for diagnosing rotor faults. To complete the accurate recognition of rotor states, a novel evaluation index named characteristic frequency band energy entropy (CFBEE) was proposed to extract the defective features of rotors, and support vector machine (SVM) was employed to automatically identify the rotor fault types. Specifically, the raw vibration signal of rotor was first analyzed by a joint time-frequency method based on improved singular spectrum decomposition (ISSD) and Hilbert transform (HT) to derive its time-frequency spectrum (TFS), which is named ISSD-HT TFS in this paper. Then, the CFBEE of the ISSD-HT TFS was calculated as the fault feature vector. Finally, SVM was used to complete the automatic identification of rotor faults. Simulated processing results indicate that ISSD improves the end effects of singular spectrum decomposition (SSD) and is superior to empirical mode decomposition (EMD) in extracting the sub-components of rotor vibration signal. The ISSD-HT TFS can more accurately reflect the time-frequency information compared to the EMD-HT TFS. Experimental verification demonstrates that the proposed method can accurately identify rotor defect types and outperform some other methods.
Collapse
|
26
|
A Computational Framework to Benchmark Basket Catheter Guided Ablation in Atrial Fibrillation. Front Physiol 2018; 9:1251. [PMID: 30298012 PMCID: PMC6161611 DOI: 10.3389/fphys.2018.01251] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Accepted: 08/20/2018] [Indexed: 11/13/2022] Open
Abstract
Catheter ablation is a curative therapeutic approach for atrial fibrillation (AF). Ablation of rotational sources based on basket catheter measurements has been proposed as a promising approach in patients with persistent AF to complement pulmonary vein isolation. However, clinically reported success rates are equivocal calling for a mechanistic investigation under controlled conditions. We present a computational framework to benchmark ablation strategies considering the whole cycle from excitation propagation to electrogram acquisition and processing to virtual therapy. Fibrillation was induced in a patient-specific 3D volumetric model of the left atrium, which was homogeneously remodeled to sustain reentry. The resulting extracellular potential field was sampled using models of grid catheters as well as realistically deformed basket catheters considering the specific atrial anatomy. The virtual electrograms were processed to compute phase singularity density maps to target rotor tips with up to three circular ablations. Stable rotors were successfully induced in different regions of the homogeneously remodeled atrium showing that rotors are not constrained to unique anatomical structures or locations. Density maps of rotor tip trajectories correctly identified and located the rotors (deviation < 10 mm) based on catheter recordings only for sufficient resolution (inter-electrode distance ≤3 mm) and proximity to the wall (≤10 mm). Targeting rotor sites with ablation did not stop reentries in the homogeneously remodeled atria independent from lesion size (1-7 mm radius), from linearly connecting lesions with anatomical obstacles, and from the number of rotors targeted sequentially (≤3). Our results show that phase maps derived from intracardiac electrograms can be a powerful tool to map atrial activation patterns, yet they can also be misleading due to inaccurate localization of the rotor tip depending on electrode resolution and distance to the wall. This should be considered to avoid ablating regions that are in fact free of rotor sources of AF. In our experience, ablation of rotor sites was not successful to stop fibrillation. Our comprehensive simulation framework provides the means to holistically benchmark ablation strategies in silico under consideration of all steps involved in electrogram-based therapy and, in future, could be used to study more heterogeneously remodeled disease states as well.
Collapse
|
27
|
Rotor Mapping in Atrial Fibrillation: Driven to Distraction? JACC Clin Electrophysiol 2018; 4:135-137. [PMID: 29600777 DOI: 10.1016/j.jacep.2017.11.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2017] [Accepted: 11/16/2017] [Indexed: 10/18/2022]
|
28
|
Not all rotors, effective ablation targets for nonparoxysmal atrial fibrillation, are included in areas suggested by conventional indirect indicators of atrial fibrillation drivers: ExTRa Mapping project. J Arrhythm 2018; 34:176-184. [PMID: 29657593 PMCID: PMC5891413 DOI: 10.1002/joa3.12036] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2017] [Accepted: 12/18/2017] [Indexed: 01/27/2023] Open
Abstract
Background Effects of nonparoxysmal atrial fibrillation (non-PAF) ablation targeting complex fractionated atrial electrogram (CFAE) areas and/or low voltage areas (LVAs) are still controversial. Methods and Results A recently developed online real-time phase mapping system (ExTRa Mapping) was used to conduct LVA mapping and simultaneous ExTRa and CFAE mapping in 28 non-PAF patients after pulmonary vein isolation (PVI). Nonpassively activated areas, in the form of meandering rotors and/or multiple wavelets assumed to contain non-PAF drivers, partly overlapped with CFAE/LVAs but not always coincided with them. Conclusion Real-time rotor imaging, rather than conventional indirect indicators only, might be very useful for detecting non-PAF drivers.
Collapse
|
29
|
Cost effectiveness of focal impulse and rotor modulation guided ablation added to pulmonary vein isolation for atrial fibrillation. J Cardiovasc Electrophysiol 2018; 29:526-536. [PMID: 29436112 DOI: 10.1111/jce.13449] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2017] [Revised: 12/12/2017] [Accepted: 01/08/2018] [Indexed: 11/28/2022]
Abstract
BACKGROUND Although ablation with focal impulse and rotor modulation (FIRM), as an adjunct to pulmonary vein isolation (PVI), has been shown to decrease atrial fibrillation (AF) recurrence, cost-effectiveness has not been assessed. OBJECTIVE We aimed to evaluate the cost effectiveness of FIRM-guided ablation when added to PVI in a mixed AF population. METHODS AND RESULTS We used a Markov model to estimate the costs, quality-adjusted survival, and cost effectiveness of adding FIRM ablation to PVI. AF recurrence rates were based on 3-year data from the CONFIRM trial. Model inputs for event probabilities and utilities were obtained from literature review. Costs were based on Medicare reimbursement, wholesale acquisition costs, and literature review. Three-year total costs FIRM+PVI versus PVI alone were $27,686 versus $26,924. QALYs were 2.338 versus 2.316, respectively, resulting in an incremental cost-effectiveness ratio (ICER) of $34,452 per QALY gained. Most of the cost (65-81%) was related to the index ablation procedure. Lower AF recurrence generated cost offsets of $4,266, primarily due to a reduced need for medications and repeat ablation. Probabilistic sensitivity analysis demonstrated ICER below $100,000/QALY in 74% of simulations. CONCLUSION Based on data from the CONFIRM study, the addition of FIRM to PVI does have the potential to be cost-effective due to higher quality-adjusted life years and lower follow-up costs. Value is sensitive to the incremental reduction in AF recurrence, and FIRM may have the greatest economic value in patients with greater AF symptom severity. Results from ongoing randomized trials will provide further clarity.
Collapse
|
30
|
A Secret Marriage Between Fibrosis and Atrial Fibrillation Drivers. JACC Clin Electrophysiol 2018; 4:30-32. [PMID: 29600783 DOI: 10.1016/j.jacep.2017.09.176] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Accepted: 09/21/2017] [Indexed: 11/20/2022]
|
31
|
Rotational Drivers in Atrial Fibrillation: Are Multiple Techniques Circling Similar Mechanisms? Circ Arrhythm Electrophysiol 2017; 10:CIRCEP.117.006022. [PMID: 29254949 DOI: 10.1161/circep.117.006022] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
32
|
|
33
|
Relationship Between Fibrosis Detected on Late Gadolinium-Enhanced Cardiac Magnetic Resonance and Re-Entrant Activity Assessed With Electrocardiographic Imaging in Human Persistent Atrial Fibrillation. JACC Clin Electrophysiol 2017; 4:17-29. [PMID: 29479568 DOI: 10.1016/j.jacep.2017.07.019] [Citation(s) in RCA: 81] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVES This study sought to assess the relationship between fibrosis and re-entrant activity in persistent atrial fibrillation (AF). BACKGROUND The mechanisms involved in sustaining re-entrant activity during AF are poorly understood. METHODS Forty-one patients with persistent AF (age 56 ± 12 years; 6 women) were evaluated. High-resolution electrocardiographic imaging (ECGI) was performed during AF by using a 252-chest electrode array, and phase mapping was applied to locate re-entrant activity. Sites of high re-entrant activity were defined as re-entrant regions. Late gadolinium-enhanced (LGE) cardiac magnetic resonance (CMR) was performed at 1.25 × 1.25 × 2.5 mm resolution to characterize atrial fibrosis and measure atrial volumes. The relationship between LGE burden and the number of re-entrant regions was analyzed. Local LGE density was computed and characterized at re-entrant sites. All patients underwent catheter ablation targeting re-entrant regions, the procedural endpoint being AF termination. Clinical, CMR, and ECGI predictors of acute procedural success were then analyzed. RESULTS Left atrial (LA) LGE burden was 22.1 ± 5.9% of the wall, and LA volume was 74 ± 21 ml/m2. The number of re-entrant regions was 4.3 ± 1.7 per patient. LA LGE imaging was significantly associated with the number of re-entrant regions (R = 0.52, p = 0.001), LA volume (R = 0.62, p < 0.0001), and AF duration (R = 0.54, p = 0.0007). Regional analysis demonstrated a clustering of re-entrant activity at LGE borders. Areas with high re-entrant activity showed higher local LGE density as compared with the remaining atrial areas (p < 0.0001). Failure to achieve AF termination during ablation was associated with higher LA LGE burden (p < 0.001), higher number of re-entrant regions (p < 0.001), and longer AF duration (p = 0.008). CONCLUSIONS The number of re-entrant regions during AF relates to the extent of LGE on CMR, with the location of these regions clustering to LGE areas. These characteristics affect procedural outcomes of ablation.
Collapse
|
34
|
Efficacy and safety of driver-guided catheter ablation for atrial fibrillation: A systematic review and meta-analysis. J Cardiovasc Electrophysiol 2017; 28:1371-1378. [PMID: 28800192 DOI: 10.1111/jce.13313] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2017] [Revised: 08/01/2017] [Accepted: 08/04/2017] [Indexed: 12/29/2022]
Abstract
INTRODUCTION Targeting localized drivers (electrical rotors or focal impulses) during catheter ablation for atrial fibrillation (AF) has been proposed as a strategy to improve procedural success. However, the strength and quality of the evidence to support this approach is unclear. METHODS AND RESULTS Clinical studies reporting efficacy or safety outcomes of driver-guided ablation for AF were identified in Medline, Embase, the Cochrane Central Register of Controlled Trials, the Cochrane Database of Systematic Reviews, Pubmed, and conference abstracts from major scientific meetings. Random-effects meta-analysis of efficacy outcomes from controlled studies was performed. Thirty-one reports from 30 studies were included: two randomized controlled trials, five nonrandomized controlled studies, and 23 uncontrolled studies. In controlled studies, driver-guided ablation has been associated with higher rates of acute AF termination (RR 2.08, 95% CI 1.43-3.05; P < 0.001) and increased freedom from AF/atrial tachycardia (AT) at ≥1 year (RR 1.34, 95% CI 1.05-1.70; P = 0.02). Similar rates of procedural complications have been reported between ablation strategies. Overall, current data on driver-guided ablation are predominantly from nonrandomized studies with considerable heterogeneity in mapping and ablation strategies used and in clinical outcomes reported. CONCLUSION Pooled data on the efficacy of AF driver-guided catheter ablation suggest increased freedom from AF/AT relative to conventional strategies. However, most studies are nonrandomized and of moderate quality. Though promising data exist, there remains no conclusive evidence for the efficacy of AF driver ablation. Robust data from randomized trials are needed.
Collapse
|
35
|
Spatial Resolution Requirements for Accurate Identification of Drivers of Atrial Fibrillation. Circ Arrhythm Electrophysiol 2017; 10:e004899. [PMID: 28500175 PMCID: PMC5434962 DOI: 10.1161/circep.116.004899] [Citation(s) in RCA: 85] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2016] [Accepted: 04/11/2017] [Indexed: 11/25/2022]
Abstract
Supplemental Digital Content is available in the text. Background— Recent studies have demonstrated conflicting mechanisms underlying atrial fibrillation (AF), with the spatial resolution of data often cited as a potential reason for the disagreement. The purpose of this study was to investigate whether the variation in spatial resolution of mapping may lead to misinterpretation of the underlying mechanism in persistent AF. Methods and Results— Simulations of rotors and focal sources were performed to estimate the minimum number of recording points required to correctly identify the underlying AF mechanism. The effects of different data types (action potentials and unipolar or bipolar electrograms) and rotor stability on resolution requirements were investigated. We also determined the ability of clinically used endocardial catheters to identify AF mechanisms using clinically recorded and simulated data. The spatial resolution required for correct identification of rotors and focal sources is a linear function of spatial wavelength (the distance between wavefronts) of the arrhythmia. Rotor localization errors are larger for electrogram data than for action potential data. Stationary rotors are more reliably identified compared with meandering trajectories, for any given spatial resolution. All clinical high-resolution multipolar catheters are of sufficient resolution to accurately detect and track rotors when placed over the rotor core although the low-resolution basket catheter is prone to false detections and may incorrectly identify rotors that are not present. Conclusions— The spatial resolution of AF data can significantly affect the interpretation of the underlying AF mechanism. Therefore, the interpretation of human AF data must be taken in the context of the spatial resolution of the recordings.
Collapse
|
36
|
Novel approaches for quantitative electrogram analysis for intraprocedural guidance for catheter ablation: A case of a patient with persistent atrial fibrillation. NUCLEAR MEDICINE AND BIOMEDICAL IMAGING 2017; 2:10.15761/NMBI.1000121. [PMID: 29399641 PMCID: PMC5796430 DOI: 10.15761/nmbi.1000121] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
PURPOSE Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia that causes stroke affecting more than 2.3 million people in the US and is increasing in prevalence due to ageing population causing a new global epidemic. Catheter ablation with pulmonary vein isolation (PVI) to terminate AF is successful for paroxysmal AF but suffers limitations with persistent AF patients as current mapping methods cannot identify AF active substrates outside of PVI region. Recent evidences in the mechanistic understating of AF pathophysiology suggest that ectopic activity, localized re-entrant circuit with fibrillatory propagation and multiple circuit re-entries may all be involved in human AF. The authors developed novel electrogram analysis methods and validated using optical mapping data from isolated rabbit hearts to accurately identify rotor pivot points. The purpose of this study was to assess the feasibility of generating patient-specific 3D maps for intraprocedural guidance for catheter ablation using intracardiac electrograms from a persistent AF patient using novel electrogram analysis methods. METHODS A persistent AF patient with clinical appointment for AF ablation was recruited for this study with IRB approval. 1055 electrograms throughout the left and right atrium were obtained for offline analysis with the novel approaches such as multiscale entropy, multiscale frequency, recurrence period density entropy, kurtosis and empirical mode decomposition to generate patient specific 3D maps. 3D Shannon Entropy, Renyi Entropy and Dominant frequency maps were also generated for comparison purposes along with local activation time and complex fractionated electrogram analysis maps. RESULTS Patient specific 3D maps were obtained for each of the different approach. The 3D maps indicate potential active sites outside the PVI region. However, presence of rotors cannot be confirmed and validation of these approaches is required on a larger dataset. CONCLUSIONS Conventional catheter mapping system can be used for generating patient specific 3D maps with short time series analysis using the novel approaches.
Collapse
|
37
|
CARTOFINDER: Can it "Find" Rotors in Atrial Fibrillation? JACC Clin Electrophysiol 2016; 3:217-219. [PMID: 29759515 DOI: 10.1016/j.jacep.2016.09.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2016] [Accepted: 09/22/2016] [Indexed: 11/24/2022]
|
38
|
Domain-based biophysical characterization of the structural and thermal stability of FliG, an essential rotor component of the Na +-driven flagellar motor. Biophys Physicobiol 2016; 13:227-233. [PMID: 27924278 PMCID: PMC5113609 DOI: 10.2142/biophysico.13.0_227] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2016] [Accepted: 08/22/2016] [Indexed: 01/16/2023] Open
Abstract
Many bacteria move using their flagellar motor, which generates torque through the interaction between the stator and rotor. The most important component of the rotor for torque generation is FliG. FliG consists of three domains: FliGN, FliGM, and FliGC. FliGC contains a site(s) that interacts with the stator. In this study, we examined the physical properties of three FliG constructs, FliGFull, FliGMC, and FliGC, derived from sodium-driven polar flagella of marine Vibrio. Size exclusion chromatography revealed that FliG changes conformational states under two different pH conditions. Circular dichroism spectroscopy also revealed that the contents of α-helices in FliG slightly changed under these pH conditions. Furthermore, we examined the thermal stability of the FliG constructs using differential scanning calorimetry. Based on the results, we speculate that each domain of FliG denatures independently. This study provides basic information on the biophysical characteristics of FliG, a component of the flagellar motor.
Collapse
|
39
|
Spatial Relationship of Focal Impulses, Rotors and Low Voltage Zones in Patients With Persistent Atrial Fibrillation. J Cardiovasc Electrophysiol 2016; 27:507-14. [PMID: 26732468 DOI: 10.1111/jce.12913] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2015] [Revised: 12/14/2015] [Accepted: 12/28/2015] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Focal impulses (FI) and rotors are sources associated with the initiation and maintenance of atrial fibrillation (AF). Their ablation results in a lower recurrence rate. The aim of this study was to characterize for the first time the spatial relationship between such sources and atrial low voltage zones (LVZ) representing fibrosis. METHODS Twenty-five consecutive patients undergoing their first ablation for persistent AF were included. Voltage mapping of both atria was done during AF. Endocardial mapping of FI and rotors (sources) was performed using a basket catheter and displayed using RhythmView(TM) (Topera Inc.) before ablation. Spatial relationship of LVZ and sources was analyzed. RESULTS LVZs covered 13 ± 12% of right atrial (RA) endocardial surface and 33 ± 25% of left atrial (LA) endocardial surface. The median number of sources was 1 [1-3] in RA and 3 [1-4] in LA. Of LA sources, 18 (30%) were definitely not associated with LVZs or pulmonary vein (PV) antra. Of RA sources, 32 (84%) were remote from LVZ. During ablation of such sources substantial cycle length (CL) prolongation or AF conversion occurred in 11/23 patients (48%). Altogether, 8/11 (73%) of these pertinent sources were located remotely from LVZ and PV antra. CONCLUSIONS There is a wide discrepancy in distribution of LVZ areas and sites of identified rotors. Site and incidence of FIRM sources appear to be unpredictable with atrial substrate mapping. Further prospective, randomized studies are necessary to elucidate the impact of additional ablation of such sources in patients with persistent or longstanding persistent AF.
Collapse
|
40
|
Phase synchrony reveals organization in human atrial fibrillation. Am J Physiol Heart Circ Physiol 2015; 309:H2118-26. [PMID: 26475585 PMCID: PMC4698428 DOI: 10.1152/ajpheart.00407.2015] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2015] [Accepted: 10/12/2015] [Indexed: 11/22/2022]
Abstract
It remains unclear if human atrial fibrillation (AF) is spatially nonhierarchical or exhibits a hierarchy of organization sustained by sources. We utilize activation times obtained at discrete locations during AF to compute the phase synchrony between tissue regions, to examine underlying spatial dynamics throughout both atria. We construct a binary synchronization network and show that this network can accurately define regions of coherence in coarse-grained in silico data. Specifically, domains controlled by spiral waves exhibit regions of high phase synchrony. We then apply this analysis to clinical data from patients experiencing cardiac arrhythmias using multielectrode catheters to simultaneously record from a majority of both atria. We show that pharmaceutical intervention with ibutilide organizes activation by increasing the size of the synchronized domain in AF and quantify the increase in temporal organization when arrhythmia changes from fibrillation to tachycardia. Finally, in recordings from 24 patients in AF we show that the level of synchrony is spatially broad with some patients showing large spatially contiguous regions of synchronization, while in others synchrony is localized to small pockets. Using computer simulations, we show that this distribution is inconsistent with distributions obtained from simulations that mimic multiwavelet reentry but is consistent with mechanisms in which one or more spatially conserved spiral waves is surrounded by tissue in which activation is disorganized.
Collapse
|
41
|
Mechanisms for the Termination of Atrial Fibrillation by Localized Ablation: Computational and Clinical Studies. Circ Arrhythm Electrophysiol 2015; 8:1325-33. [PMID: 26359479 PMCID: PMC4764078 DOI: 10.1161/circep.115.002956] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2015] [Accepted: 08/20/2015] [Indexed: 12/26/2022]
Abstract
BACKGROUND Human atrial fibrillation (AF) can terminate after ablating localized regions, which supports the existence of localized rotors (spiral waves) or focal drivers. However, it is unclear why ablation near a spiral wave tip would terminate AF and not anchor reentry. We addressed this question by analyzing competing mechanisms for AF termination in numeric simulations, referenced to clinical observations. METHODS AND RESULTS Spiral wave reentry was simulated in monodomain 2-dimensional myocyte sheets using clinically realistic rate-dependent values for repolarization and conduction. Heterogeneous models were created by introduction of parameterized variations in tissue excitability. Ablation lesions were applied as nonconducting circular regions. Models confirmed that localized ablation may anchor spiral wave reentry, producing organized tachycardias. Several mechanisms referenced to clinical observations explained termination of AF to sinus rhythm. First, lesions may create an excitable gap vulnerable to invasion by fibrillatory waves. Second, ablation of rotors in regions of low-excitability (from remodeling) produced re-entry in more excitable tissue allowing collision of wavefront and back. Conversely, ablation of rotors in high-excitability regions migrated spiral waves to less excitable tissue, where they detached to collide with nonconducting boundaries. Third, ablation may connect rotors to nonconducting anatomic orifices. Fourth, reentry through slow-conducting channels may terminate if ablation closes these channels. CONCLUSIONS Limited ablation can terminate AF by several mechanisms. These data shed light on how clinical AF may be sustained in patients' atria, emphasizing heterogeneities in tissue excitability, slow-conducting channels, and obstacles that are increasingly detectable in patients and should be the focus of future translational studies.
Collapse
|
42
|
Targeting Atrial Fibrillation Rotors: Does Being Close Count? JACC Clin Electrophysiol 2015; 1:270-272. [PMID: 29759315 DOI: 10.1016/j.jacep.2015.05.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2015] [Revised: 05/11/2015] [Accepted: 05/21/2015] [Indexed: 11/24/2022]
|
43
|
Temporal Stability of Rotors and Atrial Activation Patterns in Persistent Human Atrial Fibrillation: A High-Density Epicardial Mapping Study of Prolonged Recordings. JACC Clin Electrophysiol 2015; 1:14-24. [PMID: 29759334 DOI: 10.1016/j.jacep.2015.02.012] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2014] [Revised: 02/09/2015] [Accepted: 02/12/2015] [Indexed: 11/26/2022]
Abstract
OBJECTIVES This study aimed to determine the spatiotemporal stability of rotors and other atrial activation patterns over 10 min in longstanding, persistent AF, along with the relationship of rotors to short cycle-length (CL) activity. BACKGROUND The prevalence, stability, and mechanistic importance of rotors in human atrial fibrillation (AF) remain unclear. METHODS Epicardial mapping was performed in 10 patients undergoing cardiac surgery, with bipolar electrograms recorded over 10 min using a triangular plaque (area: 6.75 cm2; 117 bipoles; spacing: 2.5 mm) applied to the left atrial posterior wall (n = 9) and the right atrial free wall (n = 4). Activations were identified throughout 6 discrete 10-s segments of AF spanning 10 min, and dynamic activation mapping was performed. The distributions of 4,557 generated activation patterns within each mapped region were compared between the 6 segments. RESULTS The dominant activation pattern was the simultaneous presence of multiple narrow wave fronts (26%). Twelve percent of activations represented transient rotors, seen in 85% of mapped regions with a median duration of 3 rotations. A total of 87% were centered on an area of short CL activity (<100 ms), although such activity had a positive predictive value for rotors of only 0.12. The distribution of activation patterns and wave-front directionality were highly stable over time, with a single dominant pattern within a 10-s AF segment recurring across all 6 segments in 62% of mapped regions. CONCLUSIONS In patients with longstanding, persistent AF, activation patterns are spatiotemporally stable over 10 min. Transient rotors can be demonstrated in the majority of mapped regions, are spatiotemporally associated with short CL activity, and, when recurrent, demonstrate anatomical determinism.
Collapse
|
44
|
Quantification of the transmural dynamics of atrial fibrillation by simultaneous endocardial and epicardial optical mapping in an acute sheep model. Circ Arrhythm Electrophysiol 2015; 8:456-65. [PMID: 25713215 DOI: 10.1161/circep.114.002545] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2014] [Accepted: 02/09/2015] [Indexed: 11/16/2022]
Abstract
BACKGROUND Therapy strategies for atrial fibrillation based on electric characterization are becoming viable personalized medicine approaches to treat a notoriously difficult disease. In light of these approaches that rely on high-density surface mapping, this study aims to evaluate the presence of 3-dimensional electric substrate variations within the transmural wall during acute episodes of atrial fibrillation. METHODS AND RESULTS Optical signals were simultaneously acquired from the epicardial and endocardial tissue during acute fibrillation in ovine isolated left atria. Dominant frequency, regularity index, propagation angles, and phase dynamics were assessed and correlated across imaging planes to gauge the synchrony of the activation patterns compared with paced rhythms. Static frequency parameters were well correlated spatially between the endocardium and the epicardium (dominant frequency, 0.79 ± 0.06 and regularity index, 0.93 ± 0.009). However, dynamic tracking of propagation vectors and phase singularity trajectories revealed discordant activity across the transmural wall. The absolute value of the difference in the number, spatial stability, and temporal stability of phase singularities between the epicardial and the endocardial planes was significantly >0 with a median difference of 1.0, 9.27%, and 19.75%, respectively. The number of wavefronts with respect to time was significantly less correlated and the difference in propagation angle was significantly larger in fibrillation compared with paced rhythms. CONCLUSIONS Atrial fibrillation substrates are dynamic 3-dimensional structures with a range of discordance between the epicardial and the endocardial tissue. The results of this study suggest that transmural propagation may play a role in atrial fibrillation maintenance mechanisms.
Collapse
|
45
|
|
46
|
Mechanisms of Atrial Fibrillation - Reentry, Rotors and Reality. Arrhythm Electrophysiol Rev 2014; 3:90-100. [PMID: 26835073 DOI: 10.15420/aer.2014.3.2.90] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/06/2014] [Accepted: 08/08/2014] [Indexed: 01/02/2023] Open
Abstract
Atrial fibrillation (AF) is the most common sustained arrhythmia encountered in clinical practice, yet our understanding of the mechanisms that initiate and sustain this arrhythmia remains quite poor. Over the last 50 years, various mechanisms of AF have been proposed, yet none has been consistently observed in both experimental studies and in humans. Recently, there has been increasing interest in understanding how spiral waves or rotors - which are specific, organised forms of functional reentry - sustain human AF and how they might be therapeutic targets for catheter-based ablation. The following review describes the historical understanding of reentry and AF mechanisms from earlier in the 20th century, advances in our understanding of mechanisms that are able to sustain AF with a focus on rotors and complex fractionated atrial electrograms (CFAEs), and how the study of AF mechanisms has resulted in new strategies for treating AF with novel forms of catheter ablation.
Collapse
|
47
|
The influence of rotor type and centrifugation time on the yield and purity of extracellular vesicles. J Extracell Vesicles 2014; 3:23111. [PMID: 24678386 PMCID: PMC3967015 DOI: 10.3402/jev.v3.23111] [Citation(s) in RCA: 302] [Impact Index Per Article: 30.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2013] [Revised: 02/28/2014] [Accepted: 02/28/2014] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND Extracellular vesicles (EV), the collective term for vesicles released from cells, consist of vesicle species ranging in size from 30 nm to 5 µm in diameter. These vesicles are most commonly isolated by differential centrifugations, which pellets particles based on their differential movement through the liquid medium in which they are immersed. Multiple parameters, including the utilization of different rotor types, can influence the yield and purity of isolated vesicles; however, the understanding of how these factors affect is limited. MATERIALS AND METHODS Here, we compare the influence of multiple centrifugation parameters, including the use of swinging bucket and fixed angle rotors, as well as different centrifugation times, for the isolation of the smallest EVs, "exosomes." In particular, we determine the yields of exosomal RNA and protein, as well as the nature of the isolated vesicles and possible protein contamination with methods such as electron microscopy, western blot and flow cytometry. RESULTS Our results show that application of a specific g-force or rotation speed by itself does not predict the ability of pelleting exosomes, and that prolonged centrifugation times can achieve greater yields of exosomal RNA and protein, whereas very long centrifugation times result in excessive protein concentrations in the exosome pellet. CONCLUSION In conclusion, rotor type, g-force and centrifugation times significantly influence exosome yield during centrifugation-based isolation procedures, and current commonly recommended isolation protocols may not be fully optimized for yield and purity of exosomes.
Collapse
|
48
|
Principles of cardiac electric propagation and their implications for re-entrant arrhythmias. Circ Arrhythm Electrophysiol 2013; 6:655-61. [PMID: 23778249 DOI: 10.1161/circep.113.000311] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
49
|
Direct or coincidental elimination of stable rotors or focal sources may explain successful atrial fibrillation ablation: on-treatment analysis of the CONFIRM trial (Conventional ablation for AF with or without focal impulse and rotor modulation). J Am Coll Cardiol 2013; 62:138-147. [PMID: 23563126 PMCID: PMC3703494 DOI: 10.1016/j.jacc.2013.03.021] [Citation(s) in RCA: 171] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2013] [Revised: 03/04/2013] [Accepted: 03/20/2013] [Indexed: 12/19/2022]
Abstract
OBJECTIVES This study sought to determine whether ablation of recently described stable atrial fibrillation (AF) sources, either directly by Focal Impulse and Rotor Modulation (FIRM) or coincidentally when anatomic ablation passes through AF sources, may explain long-term freedom from AF. BACKGROUND It is unclear why conventional anatomic AF ablation can be effective in some patients yet ineffective in others with similar profiles. METHODS The CONFIRM (Conventional Ablation for AF With or Without Focal Impulse and Rotor Modulation) trial prospectively revealed stable AF rotors or focal sources in 98 of 101 subjects with AF at 107 consecutive ablation cases. In 1:2 fashion, subjects received targeted source ablation (FIRM) followed by conventional ablation, or conventional ablation alone. We determined whether ablation lesions on electroanatomic maps passed through AF sources on FIRM maps. RESULTS Subjects who completed follow-up (n = 94; 71.2% with persistent AF) showed 2.3 ± 1.1 concurrent AF rotors or focal sources that lay near pulmonary veins (22.8%), left atrial roof (16.0%), and elsewhere in the left (28.2%) and right (33.0%) atria. AF sources were ablated directly in 100% of FIRM cases and coincidentally (e.g., left atrial roof) in 45% of conventional cases (p < 0.05). During a median (interquartile range) of 273 days (138 to 636 days) after one procedure, AF was absent in 80.3% of patients if sources were ablated but in only 18.2% of patients if sources were missed (p < 0.001). Freedom from AF was highest if all sources were ablated, intermediate if some sources were ablated, and lowest if no sources were ablated (p < 0.001). CONCLUSIONS Elimination of stable AF rotors and focal sources may explain freedom from AF after diverse approaches to ablation. Patient-specific AF source distributions are consistent with the reported success of specific anatomic lesion sets and of widespread ablation. These results support targeting AF sources to reduce unnecessary ablation, and motivate studies on FIRM-only ablation.
Collapse
|
50
|
Abstract
Therapy for atrial fibrillation (AF) remains suboptimal, in large part because its mechanisms are unclear. While pulmonary vein ectopy may trigger AF, it remains uncertain how AF, once triggered, is actually sustained. Recent discoveries show that human AF is maintained by a small number of rotors or focal sources. AF sources are widely distributed in patient-specific locations, often remote from pulmonary veins and in the right atrium and stable for prolonged periods of time. In a multicentre experience, brief targeted ablation at sources (focal impulse and rotor modulation [FIRM]) terminated AF predominantly to sinus rhythm prior to pulmonary vein isolation and eliminated AF on rigorous followup. This review summarises the evidence for stable rotors and focal sources of human AF and their clinical role as ablation targets to eliminate paroxysmal, persistent and long-standing persistent AF.
Collapse
|