1
|
General Muscle Torque Generator Model for a Two Degree-of-Freedom Shoulder Joint. J Biomech Eng 2024; 146:081008. [PMID: 38470378 DOI: 10.1115/1.4065044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Accepted: 03/04/2024] [Indexed: 03/13/2024]
Abstract
Muscle torque generators (MTGs) have been developed as an alternative to muscle-force models, reducing the muscle-force model complexity to a single torque at the joint. Current MTGs can only be applied to single Degree-of-freedom (DoF) joints, leading to complications in modeling joints with multiple-DoFs such as the shoulder. This study aimed to develop an MTG model that accounts for the coupling between 2-DoF at the shoulder joint: shoulder plane of elevation (horizontal abduction/adduction) and shoulder elevation (flexion/extension). Three different 2-DoF MTG equations were developed to model the coupling between these two movements. Net joint torques at the shoulder were determined for 20 participants (10 females and 10 males) in isometric, isokinetic, and passive tests. Curve and surface polynomial fitting were used to find the best general fit for the experimental data in terms of the different degrees of coupling. The models were validated against experimental isokinetic torque data. It was determined that implicit coupling that used interpolation between single-DoF MTGs resulted in the lowest root-mean-square percent error of 8.5%. The work demonstrated that general MTG models can predict torque results that are dependent on multiple-DoFs of the shoulder.
Collapse
|
2
|
Ultrasound findings of the sternoclavicular and shoulder joints in patients on maintenance hemodialysis. Ther Apher Dial 2024; 28:371-379. [PMID: 38084611 DOI: 10.1111/1744-9987.14093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 11/12/2023] [Accepted: 11/23/2023] [Indexed: 04/30/2024]
Abstract
INTRODUCTION Ultrasonographic examination of joints is a non-invasive method to detect and monitor Dialysis-associated amyloidosis (DRA). METHODS An ultrasonographic examination of the sternoclavicular (SC) and shoulder joints was performed in patients on maintenance hemodialysis (MHD) and those with normal renal function in the control group. The maximum distance (D) of SC, the rotator cuff thickness (RCs), and the echogenic pads (EPs) of the shoulder were evaluated. RESULTS Compared with the control group, the MHD group had a higher D of SC, a higher proportion of RCs ≥8 mm, and a higher proportion of EPs positive. Adjust for age and Kt/V, the D of SC was positively related to dialysis vintage, standardized coefficients β = 0.329, p = 0.004. A significant positive correlation existed between the D of SC and the RCs. CONCLUSION In addition to the shoulder joint, the sternoclavicular is a suitable site for ultrasonographic detection of DRA.
Collapse
|
3
|
Role of Critical Shoulder Angle in Degenerative Type Rotator Cuff Tears: A Turkish Cohort Study. Med Sci Monit 2024; 30:e943703. [PMID: 38637980 PMCID: PMC11036895 DOI: 10.12659/msm.943703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Accepted: 02/07/2024] [Indexed: 04/20/2024] Open
Abstract
BACKGROUND This retrospective study investigated the association between the critical shoulder angle (CSA) and the development of full-thickness rotator cuff tears (FTRCTs) in the Turkish population. The CSA is an imaging parameter that quantifies the relationship between the inclination of the glenoid and the lateral extension of the acromion in the coronal plane. The CSA is an anatomical measurement, and higher CSA values have been associated with an increased incidence of FTRCTs. However, there is a lack of data on CSA regarding the Turkish population. MATERIAL AND METHODS In this study, CSA measurements were recorded in 2 groups: 50 patients with FTRCT who had arthroscopic repair (group 1) and 50 age- and sex-matched individuals with no FTRCT detected by magnetic resonance imaging (group 2). Sex, age, affected side, dominant side, and smoking status were recorded for each patient. The CSA measurements of the affected sides were performed on true anterior-posterior view radiographs. RESULTS The results showed a statistically significant difference between the mean CSA values of group 1 (37.48°) and group 2 (33.53°), P<0.001. CSA values of 36 and above had a sensitivity of 73.58%, specificity of 74.47%, positive predictive value of 75%, and negative predictive value of 74.47% for detecting FTRCT. CONCLUSIONS CSA measurement on radiographs is a useful diagnostic tool in the Turkish population, and an above-average CSA value is associated with a significantly increased incidence of degenerative-type FTRCT.
Collapse
|
4
|
[Research progress of ultrasound in diagnosis and treatment of shoulder joint diseases]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2024; 38:505-510. [PMID: 38632074 PMCID: PMC11024522 DOI: 10.7507/1002-1892.202312095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 03/08/2024] [Indexed: 04/19/2024]
Abstract
Objective To review the research progress of ultrasound in the diagnosis and treatment of shoulder diseases, in order to provide a theoretical basis for the further development of ultrasound in shoulder surgery. Methods The recent literature on the application of ultrasound in the shoulder joint was extensively reviewed. The application of ultrasound in the diagnosis and treatment of shoulder joint diseases, and the advantages and disadvantages of ultrasound were analysed, and the development trend of ultrasound technology in the shoulder joint area was prospected. Results At present, the diagnosis of shoulder joint diseases mainly relies on MRI, however, with the development of ultrasound technology, ultrasound with the characteristics of convenient, reliable, and real-time dynamic evaluation is more and more recognized in the diagnosis process of shoulder joint diseases, combined with three-dimensional ultrasound, ultrasound intervention, and elastography can improve the accuracy, sensitivity, and specificity of the diagnosis, and is suitable for the diagnosis and treatment of various shoulder joint diseases, which is expected to carry out early prevention of shoulder joint diseases in the future and achieve more refined and minimally invasive treatment. Conclusion Ultrasound technology has wide application prospect in shoulder joint diseases, but it is still in the developing stage, and the subjective dependence needs to be solved further.
Collapse
|
5
|
Glenosphere Size Does Not Matter in Reverse Total Shoulder Arthroplasty. Rev Bras Ortop 2024; 59:e254-e259. [PMID: 38606143 PMCID: PMC11006517 DOI: 10.1055/s-0043-1770976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Accepted: 01/24/2023] [Indexed: 04/13/2024] Open
Abstract
Objective There are few studies to date reporting on outcomes following reverse total shoulder arthroplasty with cohorts stratified by glenosphere size. The purpose of this study is to investigate the role that glenosphere size has on postoperative outcomes. Methods Patients who underwent reverse TSA between 1987 with minimum of 2.0 years of follow-up were included. Patients were stratified into two cohorts based on glenosphere size of 36mm or 40mm. Patients' range of motion, patient-reported outcomes, and radiographic variables (glenoid preoperative morphology, scapular notching, humeral loosening) were evaluated. Results All measurements of range of motion measurements with the exception of internal rotation saw significant preoperative to postoperative improvements within each cohort. There were no significant differences in postoperative range of motion, ASES, or VAS pain scores across the two cohorts. Overall, forward elevation improved to 134° ± 16° in the 36mm cohort and 133° ± 14° in the 40mm cohort ( p = 0.47). External rotation improved to 37° ± 13° for 36mm patients and 35° ± 19° for 40mm patients ( p = 0.58). In the 36mm group, internal rotation increased by 1.3 vertebral levels and 2.3 vertebral levels in the 40mm cohort. At final follow-up, the 36mm cohort had a VAS score of 2 ± 2, ASES score of 66 ± 19, and SST score of 6 ± 3. Similarly, the 40mm cohort had a VAS score of 2 ± 3, ASES score of 77 ± 28, and SST score of 9 ± 3. Conclusions Reverse TSA provides sustained improvements in range of motion and shoulder function irrespective of glenosphere size. Level of Evidence III.
Collapse
|
6
|
The Adhesive Capsulitis Corticosteroid and Dilation (ACCorD) randomized controlled trial. Bone Jt Open 2024; 5:162-173. [PMID: 38432256 PMCID: PMC10909438 DOI: 10.1302/2633-1462.53.bjo-2023-0114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/05/2024] Open
Abstract
Aims Is it feasible to conduct a definitive multicentre trial in community settings of corticosteroid injections (CSI) and hydrodilation (HD) compared to CSI for patients with frozen shoulder? An adequately powered definitive randomized controlled trial (RCT) delivered in primary care will inform clinicians and the public whether hydrodilation is a clinically and cost-effective intervention. In this study, prior to a full RCT, we propose a feasibility trial to evaluate recruitment and retention by patient and clinician willingness of randomization; rates of withdrawal, crossover and attrition; and feasibility of outcome data collection from routine primary and secondary care data. Methods In the UK, the National Institute for Health and Care Excellence (NICE) advises that prompt early management of frozen shoulder is initiated in primary care settings with analgesia, physiotherapy, and joint injections; most people can be managed without an operation. Currently, there is variation in the type of joint injection: 1) CSI, thought to reduce the inflammation of the capsule reducing pain; and 2) HD, where a small volume of fluid is injected into the shoulder joint along with the steroid, aiming to stretch the capsule of the shoulder to improve pain, but also allowing greater movement. The creation of musculoskeletal hubs nationwide provides infrastructure for the early and effective management of frozen shoulder. This potentially reduces costs to individuals and the wider NHS perhaps negating the need for a secondary care referral. Results We will conduct a multicentre RCT comparing CSI and HD in combination with CSI alone. Patients aged 18 years and over with a clinical diagnosis of frozen shoulder will be randomized and blinded to receive either CSI and HD in combination, or CSI alone. Feasibility outcomes include the rate of randomization as a proportion of eligible patients and the ability to use routinely collected data for outcome evaluation. This study has involved patients and the public in the trial design, dissemination methods, and how to include groups who are underserved by research. Conclusion We will disseminate findings among musculoskeletal clinicians via the British Orthopaedic Association, the Chartered Society of Physiotherapy, the Royal College of Radiologists, and the Royal College of General Practitioners. To ensure wide reach we will communicate findings through our established network of charities and organizations, in addition to preparing dissemination findings in Bangla and Urdu (commonly spoken languages in northeast London). If a full trial is shown to be feasible, we will seek additional National Institute for Health and Care Research funding for a definitive RCT. This definitive study will inform NICE guidelines for the management of frozen shoulder.
Collapse
|
7
|
High Complication and Revision Rates in Anatomical Total Shoulder Arthroplasty with the Combination of Polyethylene and Cementless Convertible Metal-Backed Glenoid Components: A Retrospective Cohort Study. Orthop Res Rev 2024; 16:93-101. [PMID: 38434716 PMCID: PMC10908272 DOI: 10.2147/orr.s442128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 02/08/2024] [Indexed: 03/05/2024] Open
Abstract
Background Historically, Metal-Backed (MB) glenoid components in anatomical total Shoulder arthroplasty (aTSA) are prone to failure primarily due to loosening between the metal and bony surface. However, newer generations of MB glenoid components have performed well in reverse shoulder arthroplasty (RSA), with convertibility being considered to be the most significant benefit of MB components. Theoretically, MB components may be a viable option in "Rotator cuff at risk" cases. The aim of this study is to compare revisions versus revision-free survivorship and highlight problems associated with using convertible MB glenoid components in aTSA. Methods Between December 2015 and September 2018, aTSA was performed on 30 patients utilizing 32 implants with convertible MB glenoid (two patients were operated bilaterally). The first investigation was performed at a mean of 55.9 months (43-76) by search in the national registry for revisions with twelve cases. The second FU on all remaining patients without revisions was conducted at a mean of 54.9 months (46-71) through physical examination with fourteen patients (sixteen implants), with four patients missing. Demographic data, indications, complications, revisions, and re-operations were recorded for each patient. Results High rates of complications led to revisions or re-operation in aTSA in combination with MB (15/32). Seven problems were associated with polyethylene (PE), which included loosening, disengagement, or wear. Eight complications were not directly associated with the MB component. There was one with loosening on the metal-bone interface side. Conversion to RSA was possible in three cases, and secondary cuff failure was seen once. High infection rates (2/32) led to a different strategy for antibiotics and preoperative preparations. Conclusion MB glenoid components caused unacceptably high complication and revision rates in aTSA. PE wear, disengagement, or loosening were the main reasons for revisions. Therefore, procedures with MB glenoid components were abandoned in aTSA. Level of Evidence Level IV case series, treatment study.
Collapse
|
8
|
Outcomes of Superior Capsular Reconstruction Using the Long Head of the Biceps Tendon in Large to Massive Rotator Cuff Tears: A Meta-Analysis and Systematic Review. J Clin Med 2024; 13:1052. [PMID: 38398365 PMCID: PMC10889218 DOI: 10.3390/jcm13041052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 01/26/2024] [Accepted: 02/09/2024] [Indexed: 02/25/2024] Open
Abstract
(1) Background: Addressing large to massive rotator cuff tears (LMRCTs) poses complex challenges. This systematic review investigated outcomes of superior capsular reconstruction (SCR) with the long head of the biceps tendon (LHBT) compared to conventional rotator cuff repair (RCR) for LMRCTs. (2) Methods: A systematic search across the MEDLINE/PubMed, EMBASE, Cochrane Library, and Scopus databases until 1 October 2023 identified studies that directly compared SCR with LHBT with conventional RCR in patients with LMRCTs and included a minimum of a 12-month follow-up period. The assessed outcome measures encompassed retear rates, functional outcomes, range of motion (ROM), and acromiohumeral interval (AHI). Risk of bias assessment was conducted via the Robins-I tool. (3) Results: In six studies with 456 cases (210 SCR using LHBT and 246 using RCR), SCR with LHBT significantly reduced retear rates (OR = 0.21; 95% CI, 0.12-0.36; p < 0.01; I2 = 0%). Furthermore, SCR with LHBT showed significant improvement in range of forward flexion (SMD 0.32, 95% CI: 0.09-0.55, p < 0.01, I2 = 39%) and AHI (SMD 0.61, 95% CI: 0.31-0.92, p < 0.01, I2 = 0%) postoperatively. (4) Conclusion: SCR with LHBT is a safe and effective treatment for LMRCTs, reducing retear rates, maintaining greater postoperative AHI, and improving ROM compared to conventional RCR. Additional high-quality interventional studies are needed to confirm these results.
Collapse
|
9
|
Treatment outcomes in post-stroke shoulder-hand syndrome: The role of combined acupuncture, traditional Chinese herb hot compress and rehabilitation training. J Back Musculoskelet Rehabil 2024:BMR230267. [PMID: 38517771 DOI: 10.3233/bmr-230267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/24/2024]
Abstract
BACKGROUND Acupuncture, traditional Chinese herb hot compress and rehabilitation training is useful in post-stroke shoulder-hand syndrome (SHS), but it is less commonly used in combination. OBJECTIVE To analyse the therapeutic efficacy of a combination of acupuncture, traditional Chinese herb hot compress and rehabilitation training in SHS patients. METHOD Patients diagnosed with post-stroke SHS and treated from January 2022 to March 2023 at Beijing Friendship Hospital and Beijing Pinggu Hospital were selected and randomly divided into three groups (A, B and C). Group A received conventional rehabilitative treatment (35 cases), Group B underwent conventional rehabilitative treatment + acupuncture (35 cases), and Group C received conventional rehabilitative treatment + acupuncture + traditional Chinese herb hot compress treatment (35 cases). The post-treatment effectiveness rate, visual analogue scale (VAS) score, activities of daily living (ADL) score, Fugel-Meyer assessment (FMA) score, SHS assessment scale (SHSS) score and shoulder joint mobility were compared among the three groups. RESULTS The post-treatment VAS score (FVAS score= 232.512, P< 0.001), FMA score (FFMA score= 239.412, P< 0.001), ADL score (FADL score= 412.634, P< 0.001), SHSS score (FSHSS score= 212.542, P< 0.001) and shoulder joint mobility (FShoulder Joint Mobility= 197.531, P< 0.001) all showed statistically significant differences. The VAS and SHSS scores decreased in the order of Group A > Group B > Group C, while the FMA, ADL and shoulder joint mobility scores increased in the order of Group C > Group B > Group A. The post-treatment effectiveness rates (χ2= 48.510, P< 0.001) also exhibited statistically significant differences, decreasing in the order of Group C (94.29%) > Group B (82.86%) > Group A (71.43%). CONCLUSION The treatment efficacy of the combined acupuncture, traditional Chinese herb hot compress and rehabilitation training for SHS patients is significant, warranting its clinical promotion.
Collapse
|
10
|
Scapulohumeral subluxation and luxation in five alpacas. SCHWEIZ ARCH TIERH 2024; 166:80-91. [PMID: 38299928 DOI: doi.org/10.17236/sat00417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2024]
Abstract
INTRODUCTION The patient histories, findings from clinical examinations, diagnostic imaging techniques, the surgical procedures, complications, necropsy findings and the outcomes from five male or castrated male alpacas with scapulohumeral sub-/luxation are presented. These alpacas each had a history of severe forelimb lameness for one week (n: 1), four weeks (n: 2) and for two-to-three months (n: 2). Two of the five alpacas were euthanized due to severe osteoarthritic changes that developed during the two-to-three months of scapulohumeral luxation. Three alpacas were treated with open reduction and internal stabilisation by placing tension band sutures between one 4,5 mm cortical screw anchored in the scapular neck and two 4,5 mm cortical screws anchored in the greater humeral tubercle, all of them provided with washers. Post-surgery a carpal flexion sling was applied to avoid postoperative weight-bearing. An exercise programme was started after removal of the carpal sling and continued for 12 weeks. In one of the three alpacas an additional non-displaced fracture of the acromion occurred two weeks after surgery. In conclusion, all three treated alpacas had good-to-excellent long-term outcomes and are still alive 123, 15 and 12 months after surgical repair of the scapulohumeral sub-/luxation. As four weeks, or even up to three months elapsed in four of these five alpacas until a definitive diagnosis was made, more education should be provided to alpaca owners that severely lame animals should be presented to a veterinarian with adequate diagnostic possibilities and expertise as soon as possible in order not to compromise treatment success.
Collapse
|
11
|
Effects of an exoskeleton on muscle activity in tasks requiring arm elevation: Part I - Experiments in a controlled laboratory setting. Work 2024; 77:1179-1188. [PMID: 37980590 DOI: 10.3233/wor-230217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2023] Open
Abstract
BACKGROUND Long-term work with elevated arms, or overhead work, is a risk factor for musculoskeletal complaints and disorders. Upper-limb exoskeletons are a promising tool for reducing occupational workload when working with hands above shoulder level. OBJECTIVE The purpose of this study was to assess the effects of upper-limb exoskeleton on muscular and physical strain and perceived exertion during dynamic work at four different shoulder joint angles. Further, we evaluated if there are any negative effects associated with the use of exoskeleton. METHODS A total of 15 student participants performed dynamic work in laboratory setting with and without an exoskeleton at four different shoulder angles: 60, 90, 120 and 150 degrees. Muscle electrical activity from 8 muscles of the upper body, perceived exertion, and heart rate were measured during the work task, and grip strength, muscle stiffness, tone, and elasticity from six muscles, m. deltoideus physiological cross-sectional area and muscle fiber pennation angle, and nerve conduction velocity were measured before and after the work task. RESULTS Based on the results, the use of exoskeleton significantly reduced the muscle activity of the upper limb, shoulder, and back muscles. The reduction was most significant when the arm elevation was 120°, and in m. deltoideus muscle activity. RPE was also positively affected indicating reduction in workload when using exoskeleton. CONCLUSION The results suggest that the use of upper limb exoskeleton has potential to reduce physical workload during overhead work and, consequently, reduce the risk for work-related musculoskeletal disorders.
Collapse
|
12
|
Minimum Clinically Important Difference (MCID) and Patient Acceptable Symptomatic State (PASS) Applied to the SF-36 in Patients Who Underwent Arthroscopic Rotator Cuff Repair. J Clin Med 2023; 13:178. [PMID: 38202185 PMCID: PMC10779461 DOI: 10.3390/jcm13010178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 12/08/2023] [Accepted: 12/25/2023] [Indexed: 01/12/2024] Open
Abstract
The 36-Item Short-Form Health Survey questionnaire (SF-36) is a reliable tool to assess the health-related quality of life of patients. If a mean difference between pre-operative evaluation and final follow-up is found to be statistically significant, then the change in score is not random. However, a statistically significant mean change may not correspond to a clinical amelioration for the patient or mean that the patient's state of health is to be considered acceptable. For this reason, interest in the concepts of minimal clinically important difference (MCID) and patient acceptable symptomatic state (PASS) has grown within recent years. The goal of the present work of research was to determine the MCID and PASS values for the SF-36 in patients who received rotator cuff repair (RCR). Forty-six patients (18 women and 28 men, mean age 58.5 ± 12.9) previously diagnosed with rotator cuff disease were enrolled. All of these patients underwent RCR. They were evaluated pre-operatively and six months after the surgical intervention as a final follow-up. The SF-36 questionnaire was assessed at each evaluation. The MCID cut-offs of the total, physical, and mental dimensions of the SF-36 for patients who underwent RCR were 23.1, 32.5, and 18.1, respectively. A 23.1 improvement in the SF-36 score at six months following RCR can be correlated with patients having reached a clinically significant improvement in health status. If 81.9 or more is attained in the SF-36 score after surgical repair, the symptom state can be judged as satisfactory by the majority of patients.
Collapse
|
13
|
Role of Magnetic Resonance Imaging (MRI) in the Diagnosis of Rotator Cuff Injuries and Correlation With Arthroscopy Findings. Cureus 2023; 15:e50103. [PMID: 38192965 PMCID: PMC10771931 DOI: 10.7759/cureus.50103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Accepted: 12/04/2023] [Indexed: 01/10/2024] Open
Abstract
BACKGROUND AND AIM The prevalent cause of shoulder pain is rotator cuff tears (RCT), which induce profound discomfort and morbidity. Hence, their detection and appropriate management become important to alleviate morbidity and enhance quality of life. Imaging has an important role in the diagnosis of such patients to guide for further management. A wide array of radiological approaches has been explored for the detection of RCT. The study aimed to assess the sensitivity (SN) and specificity (SP) of regular magnetic resonance imaging (MRI) in the diagnosis and characterization of RCT and furthermore to link the results of MRI with the arthroscopy findings. The limitations and pitfalls if any with MRI patients presenting were also addressed. MATERIALS AND METHODS The study was a diagnostic evaluation study conducted at the Department of Radiodiagnosis, Muslim Educational Society (MES) Medical College, Perinthalmanna, India, among individuals with RCT between December 1, 2015, and May 31, 2017. Patients who were referred for MRI and then taken up for arthroscopy were included. The findings for each tendon of rotator cuff on MRI were contrasted with that of arthroscopy, and the percentage of agreement was calculated. Additional findings relevant to the study were also noted. SN, SP, positive predictive value (PPV), and negative predictive value (NPV) of MRI were determined by taking arthroscopic findings as the gold standard. RESULTS The study was comprised of 36 patients assessed using MRI and arthroscopy for RCT. The study participants ranged in age from 31 to 70 years, with a mean of 52.69±8.86 years. The majority of the patients (69.4%) were between the ages of 41 and 60 years. MRI had 100% SN and SP for full-thickness supraspinatus (SS) tear, 50% SN and 100% SP for partial-thickness SS tear, 100% SN and 80% SP for full-thickness infraspinatus (IS) tear, 75% SN and 80% SP for partial-thickness IS tear, and 95% SN and 86.6% SP for subscapularis (SC) tear. CONCLUSION The MRI RCT investigation had a high SN, SP, and PPV compared to arthroscopy. The most frequently involved tendon reported in the present study was SS (n=35; 97.22%) followed by IS (n=32; 88.88%) and SC (n=22; 61.11%). The teres minor tendon was least commonly affected (n=0). Moreover, 61.11% (n=22) of the patients had joint effusion, 41.66% (n=15) had subacromial-subdeltoid bursal effusion, and 27.77% (n=10) had subcoracoid effusion, suggesting that RCT include joint effusion or bursal fluid. Acromioclavicular (AC) joint hypertrophy was found in 53% (n=19) of the patients, and 90% (n=17) were over 45 years old, indicating an association between age, AC joint hypertrophy, and RCT. Therefore, MRI has a good SN and SP for detecting various RCT. Therefore, it could be used to investigate a suspected RCT and should be considered a near-reference standard to arthroscopy for RCT diagnosis.
Collapse
|
14
|
Validity and Reliability of POM-Checker for Measuring Shoulder Range of Motion in Healthy Participants: A Pilot Single-Center Comparative Study. Methods Protoc 2023; 6:114. [PMID: 38133134 PMCID: PMC10745328 DOI: 10.3390/mps6060114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 11/22/2023] [Accepted: 11/23/2023] [Indexed: 12/23/2023] Open
Abstract
BACKGROUND The aim of this study was to compare shoulder movement measurements between a Kinect-based markerless ROM assessment device (POM-Checker) and a 3D motion capture analysis system (BTS SMART DX-400). METHODS This was a single-visit clinical trial designed to evaluate the validity and reliability of the POM-Checker. The primary outcome was to assess the equivalence between two measurement devices within the same set of participants, aiming to evaluate the validity of the POM-Checker compared to the gold standard device (3D Motion Analysis System). As this was a pilot study, six participants were included. RESULTS The intraclass correlation coefficient (ICC) and the corresponding 95% confidence intervals (CIs) were used to assess the reproducibility of the measurements. Among the 18 movements analyzed, 16 exhibited ICC values of >0.75, indicating excellent reproducibility. CONCLUSION The results showed that the POM-checker is reliable and validated to measure the range of motion of the shoulder joint.
Collapse
|
15
|
Association of obesity with high retears and complication rates, and low functional scores after rotator cuff repair: a systematic review and meta-analysis. J Shoulder Elbow Surg 2023; 32:2400-2411. [PMID: 37419440 DOI: 10.1016/j.jse.2023.05.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 05/07/2023] [Accepted: 05/21/2023] [Indexed: 07/09/2023]
Abstract
BACKGROUND Obesity influences the outcomes of orthopedic surgeries such as total knee arthroplasty and spinal surgery. However, the effect of obesity on the outcomes of rotator cuff repair is unknown. This systematic review and meta-analysis aimed to examine the effect of obesity on rotator cuff repair outcomes. METHODS PubMed, EMBASE, Web of Science, and Cochrane Library databases were searched to identify relevant studies published from their inception till July 2022. Two reviewers independently screened titles and abstracts using the specified criteria. Articles were included if they indicated the effect of obesity on rotator cuff repair and the related outcomes after surgery. Review Manager 5.4.1 software was used to perform statistical analysis. RESULTS Thirteen articles involving 85,497 patients were included. Obese patients had higher retear rates than nonobese patients (odds ratio [OR] 2.58, 95% confidence interval [CI] 1.23-5.41, P = .01), lower American Shoulder and Elbow Surgeons scores (mean difference [MD]: -3.59, 95% CI: -5.45 to [-1.74]; P = .0001), higher visual analog scale for pain (mean difference: 0.73, 95% CI: 0.29-1.17; P = .001), higher reoperation rates (OR 1.31, 95% CI 1.21-1.42, P < .00001), and higher rates of complications (OR 1.57, 95% CI 1.31-1.87, P = .000). Obesity did not affect the duration of surgery (MD: 6.03, 95% CI: -7.63 to 19.69; P = .39) or external rotation of the shoulder (MD: -1.79, 95% CI: -5.30 to 1.72; P = .32). CONCLUSION Obesity is a significant risk factor for retear and reoperation after rotator cuff repair. Furthermore, obesity increases the risk of postoperative complications and leads to lower postoperative American Shoulder and Elbow Surgeons scores and higher shoulder visual analog scale for pain.
Collapse
|
16
|
3D-printed custom implant for the management of "locked" posterior dislocation of the shoulder joint with reverse Hill-Sachs lesion: a case report. Front Bioeng Biotechnol 2023; 11:1259255. [PMID: 37877040 PMCID: PMC10590887 DOI: 10.3389/fbioe.2023.1259255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Accepted: 09/19/2023] [Indexed: 10/26/2023] Open
Abstract
Introduction: Irregular bone defects of the humerus are common in clinical practice, but there are fewer reported cases of irregular humeral defects accompanied by shoulder joint "locking" dislocation and reverse Hill-Sachs injury caused by an electric shock. The choice of treatment for such cases is closely related to the extent of shoulder joint function recovery. This is a case report of a 60-year-old male patient who suffered from a shoulder joint "locking" dislocation with accompanying reverse Hill-Sachs injury due to muscle contraction after being electrically shocked at work. The patient was treated with a 3D-printed custom humeral head prosthesis for the treatment of the shoulder joint "locking" dislocation and reverse Hill-Sachs injury. Case presentation: A 60-year-old male patient, working as a construction worker, presented to our emergency department with right shoulder pain and restricted movement for more than 30 min after an electric shock. Right humeral CT revealed a comminuted fracture of the right humeral head. D-dimer levels were significantly elevated at 3239.00 ng/mL, and oxygen partial pressure was slightly decreased at 68 mmHg. Treatment included emergency wound debridement and dressing for the electrical injury, cardioprotective measures, anticoagulation, and symptomatic management. After stabilizing the patient's condition, the patient underwent 3D-printed custom prosthesis-assisted partial replacement of the right humeral head and rotator cuff repair in the orthopedic department. Postoperatively, the patient's right shoulder joint wound healed well, and mobility was restored. Conclusion: This case report demonstrates that the use of a 3D-printed custom prosthesis for the treatment of irregular humeral bone defects caused by specific injury mechanisms, especially cases involving shoulder joint "locking" dislocation and reverse Hill-Sachs injury, can achieve precise bone defect repair, minimize surgical trauma, and provide superior outcomes in terms of postoperative functional rehabilitation.
Collapse
|
17
|
Platelet-Rich Plasma for Adhesive Capsulitis: A Systematic Review. Cureus 2023; 15:e46580. [PMID: 37808592 PMCID: PMC10557468 DOI: 10.7759/cureus.46580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/06/2023] [Indexed: 10/10/2023] Open
Abstract
Adhesive capsulitis (AC) is a common cause of shoulder pain seen in 3%-5% of the population. Platelet-rich plasma (PRP) is platelet-rich blood with pro-inflammatory and anti-inflammatory properties that has been proposed as a treatment option for patients with AC. The purpose of this study was to analyze outcomes of range of motion (ROM) and subjective outcomes, including the visual analog scale (VAS), disability of arm, shoulder, and hand (DASH), and shoulder pain and disability index (SPADI) scores. PubMed, Embase, and Cochrane databases were searched, and manuscripts were screened using defined preferred reporting items for systematic reviews and meta-analyses (PRISMA) criteria. Two reviewers independently screened articles for inclusion/exclusion using PICOS criteria and extracted data regarding ROM and subjective outcome scores. Nineteen total articles were included. Eleven of the 19 studies recorded ROM as a dependent variable. All articles reported improved ROM with PRP injection when compared to baseline. When recording degrees of shoulder ROM in different planes at the latest follow-up, there were a total of 67 comparative data points for PRP vs. control. Of the 67 comparisons, 62 (93%) had a larger final ROM in the PRP group. VAS scores were reported in 16 of the 19 studies, DASH scores were reported in eight of the 19 articles, and SPADI scores were reported in seven of the 19 articles. VAS, DASH, and SPADI scores were all superior in the PRP group compared to the control. Two studies reported the same final VAS score, but the PRP groups had a larger overall improvement. Of the studies that reported objective ROM outcomes, the PRP group had greater ROM at the longest follow-up compared to control in the vast majority of comparisons. For the studies that reported subjective outcomes, all patients that received PRP had a decrease in VAS pain scores and an improvement in DASH and SPADI questionnaires.
Collapse
|
18
|
Bristow-Latarjet Surgery: A Current Overview in Brazil. Rev Bras Ortop 2023; 58:e734-e741. [PMID: 37908520 PMCID: PMC10615603 DOI: 10.1055/s-0043-1776131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 05/05/2023] [Indexed: 11/02/2023] Open
Abstract
Objective To provide a current overview of the Bristow-Latarjet surgery in Brazil. Materials and Methods This cross-sectional study was based on an electronic questionnaire with 26 items, which was sent to active members of the Brazilian Society of Shoulder and Elbow Surgery (Sociedade Brasileira de Cirurgia do Ombro e Cotovelo, SBCOC, in Portuguese). The questionnaire addressed training, surgical technique, complications, and postoperative management. Results We sent the questionnaire to 845 specialists from April 20 to May 12, 2021, and 310 of them answered i in full. During their specialization, most specialists participated in up to ten Bristow-Latarjet procedures. The most frequent complication was graft fracture, while the most common technical difficulty was screw positioning. In total, 50.6% and 73.9% reported having experienced intraoperative and postoperative complications respectively; 57.1% declared performing subscapularis suture; 99.7% indicated postoperative immobilization; and 61.9% considered graft consolidation fundamental. Conclusion Most specialists participated in up to ten Bristow-Latarjet procedures during the specialization, but 13.5% of them graduated without participating in the surgery. The most frequent complication was graft fracture. The most common technical difficulty was screw positioning. Most participants prefer postoperative immobilization since they believe graft consolidation is essential to resume the practiced of sports. The highest complication rate occurred with specialists who have obtained their titles 11 to 15 years ago. In Brazil, the Southeast region is the largest producer of specialists and has the highest concentration of these professionals.
Collapse
|
19
|
Morphometry and Morphology of the Acromion Process and Its Implications in Subacromial Impingement Syndrome. Cureus 2023; 15:e44329. [PMID: 37779751 PMCID: PMC10538576 DOI: 10.7759/cureus.44329] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/29/2023] [Indexed: 10/03/2023] Open
Abstract
Introduction Subacromial impingement syndrome (SIS) is a common shoulder disorder characterized by pain and limited range of motion in the shoulder joint. It is frequently attributed to the compression or impingement of the rotator cuff tendons and bursa between the humeral head and the acromion process of the scapula during arm elevation. Subacromial impingement syndrome may arise as a result of the morphology of the acromion process, a bony protrusion at the top of the scapula that is important in the biomechanics of the shoulder joint. In order to detect potential anatomical differences that can predispose people to subacromial impingement syndrome, medical professionals and researchers need to have a thorough understanding of the morphometry and morphology of the acromion process. Aims and objectives The aim of the present study was to measure the morphometric and morphological characteristics of the acromion process in dried human scapulae that belonged to the North Indian population. Materials and methods This was a cross-sectional study that was carried out on 120 undamaged adult human scapula, of which 52 belonged to the right side and 68 belonged to the left side. Our study focused on analyzing the morphology of the acromion process as well as determining its maximum length, maximum breadth, acromio-coracoid distance, acromio-glenoid distance, and thickness. A statistical analysis of the observed parameters was carried out using the chi-square test and independent t-test with the help of Statistical Package for the Social Sciences (SPSS, IBM Corp., Armonk, NY) 24.0. Statistical significance was set at 0.05 (if the P-value ≤ 0.05, it is significant). Results We observed that the quadrangular shape (51.67%) of the acromion process was most commonly reported in our study, while the tubular (9.99%) shape was the least common. The difference in the incidences of various shapes of the acromion process on the right and left sides of the scapula was found to be statistically significant (p-value ≤ 0.05). In this study, the curved or type II acromion process was the most common type (53.34%) observed, while the least common shape reported was the hooked type (18.33%). The average length of the right acromion process was 44.52±6.61 mm, and the left acromion process was 45.13±6.35 mm. For the breadth, the right acromion had an average value of 28.31±4.67 mm, while the left had an average of 28.34±4.92 mm. The thickness of the right acromion measured 7.10±1.73 mm, and the left acromion was 7.53±1.44 mm. The acromio-coracoid distance on the right side was 34.59 ± 6.47 mm, and the left side was 37.46±6.22 mm. The acromio-glenoid distance was measured to be 32.31±5.87 mm on the right side and 33.18±5.39 mm on the left side. Conclusions Planning and carrying out an acromioplasty require an understanding of the morphometric parameters of the acromion process. Although there is a paucity of research on its morphometric evaluation in the North Indian population, the surgeons would be able to use these data as a reference.
Collapse
|
20
|
Validation of Estimators for Weight-Bearing and Shoulder Joint Loads Using Instrumented Crutches. SENSORS (BASEL, SWITZERLAND) 2023; 23:6213. [PMID: 37448059 DOI: 10.3390/s23136213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 07/05/2023] [Accepted: 07/05/2023] [Indexed: 07/15/2023]
Abstract
This research paper aimed to validate two methods for measuring loads during walking with instrumented crutches: one method to estimate partial weight-bearing on the lower limbs and another to estimate shoulder joint reactions. Currently, gait laboratories, instrumented with high-end measurement systems, are used to extract kinematic and kinetic data, but such facilities are expensive and not accessible to all patients. The proposed method uses instrumented crutches to measure ground reaction forces and does not require any motion capture devices or force platforms. The load on the lower limbs is estimated by subtracting the forces measured by the crutches from the subject's total weight. Since the model does not consider inertia contribution in dynamic conditions, the estimation improves with low walking cadence when walking with the two-point contralateral and the three-point partial weight-bearing patterns considered for the validation tests. The shoulder joint reactions are estimated using linear regression, providing accurate values for the forces but less accurate torque estimates. The crutches data are acquired and processed in real-time, allowing for immediate feedback, and the system can be used outdoors in real-world walking conditions. The validation of this method could lead to better monitoring of partial weight-bearing and shoulder joint reactions, which could improve patient outcomes and reduce complications.
Collapse
|
21
|
Adhesive Capsulitis Secondary to COVID-19 Vaccination - A Case Series. Malays Orthop J 2023; 17:43-48. [PMID: 37583521 PMCID: PMC10425003 DOI: 10.5704/moj.2307.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2022] [Accepted: 03/23/2023] [Indexed: 08/17/2023] Open
Abstract
Introduction Shoulder injury related to vaccine administration (SIRVA) is a group of pathologies defined by pain and stiffness after intramuscular administration of vaccine to the upper arm and has been reported after COVID-19 vaccination. We aim to discuss its pathophysiology, clinical presentation, treatment and outcomes. Materials and methods We retrospectively identified patients presenting with adhesive capsulitis within four weeks of administration of COVID-19 vaccine to the affected arm at our tertiary institution from March 2021 to December 2022. Result Based on the above criteria, we identified seven cases of adhesive capsulitis, comprising one male and six female patients, with average age of 60 years. We present initial symptoms, signs and the duration from when the vaccine was administered. We have highlighted our treatment strategies as well as the clinical and functional outcomes reported by these patients after treatment. We have reported improvement in both Visual Analogue Scale (VAS) and range of motion (ROM) in all our patients after non-surgical management which included physiotherapy and, in some cases, hydrodilatation. Conclusion SIRVA related adhesive capsulitis is rare and under-reported with limited information in current literature. This study highlights that adhesive capsulitis is a potential complication arising from improper COVID-19 vaccine administration and reinforces traditional wisdom of administering vaccinations on the non-dominant arm. Conservative treatment strategies appear to be effective, particularly hydrodilatation combined with physiotherapy, and patients are expected to have a good return of function.
Collapse
|
22
|
MRI appearance of multiple displaced osteochondritis dissecans cartilage fragments in the bicipital tendon sheath of a juvenile dog. Vet Radiol Ultrasound 2023. [PMID: 36994481 DOI: 10.1111/vru.13231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 01/30/2023] [Accepted: 01/31/2023] [Indexed: 03/31/2023] Open
Abstract
A 1-year-old Bernese Mountain dog presented with an acute onset of left thoracic limb lameness. Magnetic resonance imaging (MRI) of the left shoulder was performed, showing a subchondral bone defect in the caudomedial aspect of the humeral head. In addition, several round hypointense structures were visible in the biceps tendon sheath. A left shoulder arthroscopy was performed, which confirmed an osteochondritic lesion. Exploration of the biceps tendon sheath via a small open approach allowed retrieval of the fragments, which likely migrated from the joint. Histopathology confirmed the structures to be multiple osteochondritic fragments.
Collapse
|
23
|
The morphofunctional implications of the glenoid labrum of the glenohumeral joint in hominoids. AMERICAN JOURNAL OF BIOLOGICAL ANTHROPOLOGY 2023; 181:195-205. [PMID: 36939238 DOI: 10.1002/ajpa.24729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 02/13/2023] [Accepted: 03/05/2023] [Indexed: 03/21/2023]
Abstract
OBJECTIVES A morphocline of the glenoid cavity has been used to infer differences in locomotor behaviors; however, the glenoid cavity is surrounded by the glenoid labrum, a fibrocartilaginous structure that could influence the functionality of the glenoid. The objectives of this study are to explore the effects of the glenoid labrum on the area, depth, and morphology of the glenoid cavity in primates. MATERIALS AND METHODS Photogrammetry was used to build 3D models of the glenoid, with and without the labrum, and three- (3D) and two-dimensional (2D) geometric morphometrics (GM) was applied. 2D areas were collected from zenithal images for glenoids with and without labrum to evaluate the availability of articular surface area. RESULTS In the 2D GM the morphocline is present in the dry-bone sample but not with the presence of the glenoid labrum. In the 3D GM there are differences between species mainly concerning the depth of the glenoid cavity. 2D areas reveal that the amount of articular area of the glenoid cavity increases with the presence of the labrum, particularly in humans. DISCUSSION The glenoid labrum changes the shape, increases the depth and the surface area of the glenoid cavity, particularly in humans. Therefore, the glenoid labrum might hold a functional role, increasing the stability of the glenohumeral joint of primates in general, and especially in humans.
Collapse
|
24
|
Abstract
BACKGROUND Despite recent advances in arthroscopic rotator cuff repair, the retear rate remains high. New methods to optimize healing rates must be sought. Bone channeling may create a quicker and more vigorous healing response by attracting autologous mesenchymal stem cells, cytokines, and growth factors to the repair site. HYPOTHESIS Arthroscopic rotator cuff repair with bone channeling would result in a higher healing rate compared with arthroscopic rotator cuff repair without adjuvant channeling. STUDY DESIGN Randomized controlled trial; Level of evidence, 1. METHODS Our primary objective was to compare healing rates in patients undergoing arthroscopic rotator cuff repair for degenerative tears, with and without bone channeling. Secondary objectives included comparisons of the Western Ontario Rotator Cuff Index (WORC) score, American Shoulder and Elbow Surgeons (ASES) score, Constant score, Constant strength subscore, and visual analog scale (VAS) for pain score between groups. Patients undergoing arthroscopic rotator cuff repair were recruited at 3 sites and were randomized to receive either bone channeling augmentation or standard repair. Healing was determined via ultrasound at 24 months postoperatively. WORC, ASES, and Constant scores were compared between groups at baseline and at 3, 6, 12, and 24 months postoperatively. RESULTS A total of 168 patients were enrolled between 2013 and 2018. Intention-to-treat analysis revealed no statistical differences in healing rates between the 2 interventions at 24 months postoperatively. Statistically significant improvements occurred in both groups from preoperatively to all time points for the WORC, the ASES score, the Constant score or Constant strength subscore, and the VAS for pain (P < .0001). No differences were observed between the bone channeling and control groups in WORC, ASES, Constant, and VAS pain scores at any time point. CONCLUSION This trial did not demonstrate the superiority of intraoperative bone channeling in rotator cuff repair over standard rotator cuff repair at 24 months postoperatively. Healing rates, patient-reported function, and quality-of-life outcomes were similar between groups. REGISTRATION NCT01877772 (ClinicalTrials.gov identifier).
Collapse
|
25
|
Study of arthroscopic superior capsule reconstruction in the treatment of irreparable rotator cuff tears. Front Surg 2023; 9:895571. [PMID: 36684146 PMCID: PMC9852769 DOI: 10.3389/fsurg.2022.895571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 11/22/2022] [Indexed: 01/09/2023] Open
Abstract
Background The objective of this study was to investigate the clinical outcome and radiographic findings after arthroscopic superior capsule reconstruction (ASCR) with a new augmented autograft technique for irreparable rotator cuff tears. Methods Between 2018 and 2020, 11 patients whose shoulders had irreparable rotator cuff tears underwent ASCR using a fascia lata weaving mesh. Physical examination, radiography, and magnetic resonance imaging (MRI) were performed before surgery and the average follow-up was 20 months (18-24 months) after surgery. Clinical outcome scores were recorded. Results Average clinical outcome scores improved significantly at the final follow-up, with 94.7 points scored on the American Shoulder and Elbow Surgeons scale (range, 85-100 points) and 34.5 points on the University of California, Los Angeles scale (33-35 points) (P < 0.05). Mean active elevation increased significantly from 30.1° to 150° (P < 0.05) and external rotation increased from 30° to 59.2° (P < 0.05). The acromiohumeral distance (AHD) increased from 3.9 ± 0.6 mm preoperatively to 10.1 ± 0.7 mm postoperatively (P < 0.05). No patient had graft tear or tendon retear during follow-up. Conclusions ASCR with a new augmented autograft can restore the function of the shoulder joint with irreparable rotator cuff tears. Our results suggest that this reconstruction technique can help obtain good clinical and radiographic outcomes, which can provide a reliable method for the treatment of irreparable rotator cuff tears. Level of Evidence Level IV, therapeutic case series.
Collapse
|
26
|
Steroid-induced osteonecrosis of the humeral head in a 20-year-old man treated with an osteochondral autograft: A case report. Mod Rheumatol Case Rep 2023; 7:247-251. [PMID: 35460258 DOI: 10.1093/mrcr/rxac037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Revised: 03/08/2022] [Accepted: 04/08/2022] [Indexed: 01/07/2023]
Abstract
To our knowledge, only one previous report described the treatment of osteochondral autograft for steroid-induced osteonecrosis of the humeral head (ONHH) in a middle-aged patient. The present report describes a 20-year-old man who was found to have avascular osteonecrosis of the right humeral head after corticosteroid pulse treatment, followed by oral corticosteroid therapy. The patient complained of serious right shoulder pain and limited range of motion (ROM). Anteroposterior (AP) radiographs of the right shoulder revealed a crescent sign at the humeral head, indicating subchondral bone collapse with a linear sclerotic change and normal articular surface of the glenoid. The case was categorized as Stage 3 according to the Cruess classification. In general, Cruess classification Stage 3 is treated with humeral head replacement and shoulder arthroplasty. The patient underwent surgical treatment involving osteochondral autograft transplantation. Autografts were harvested from the right knee. At the 1.5-year follow-up, the patient was pain-free and showed an improved active ROM. Furthermore, AP radiographs demonstrated that the glenohumeral joint space was maintained, and no progression of humeral head collapse was observed. This case may be helpful in decision-making if young patients with ONHH require surgical treatment. Furthermore, osteochondral autograft transplantation may be an effective treatment for ONHH.
Collapse
|
27
|
[Analysis of the effectiveness of various methods of rehabilitation of patients with subacromial impingement syndrome]. VOPROSY KURORTOLOGII, FIZIOTERAPII, I LECHEBNOI FIZICHESKOI KULTURY 2023; 100:66-76. [PMID: 38289307 DOI: 10.17116/kurort202310006166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2024]
Abstract
INTRODUCTION Subacromial impingement syndrome is a common pathology that leads to a persistent decrease in the functioning of the affected limb and, as a consequence, a decrease in the quality of life and work ability of patients. According to various authors, the study of the effectiveness of treatment and rehabilitation of this pathology is quite widely presented in the literature: surgical, including arthroscopic operations, rehabilitation using various factors of physical therapy, manual and other practices. However, the issue of assessing the effectiveness of movement therapy, both alone and in combination with other therapeutic methods, remains relevant. AIM To evaluate the effectiveness of therapeutic gymnastics procedures, both monotherapy and in combination with manual massage according to the therapeutic method and extracorporeal shock wave therapy (ESWT), in patients with subacromial impingement syndrome of the shoulder, in order to reduce pain and improve the function of the shoulder joint. MATERIAL AND METHODS The study included 70 patients whose age was 42.18±10.42 years. Patients were divided into two main groups: group 1 (n=34) and group 2 (n=36). All patients received a course of treatment, including 10 procedures of therapeutic exercises, with recommendations at the end of the course for continuation in the form of independent studies using the proven methodology. The duration of the course of therapeutic exercises (in the form of procedures with a physical therapy instructor and subsequent independent studies) was 30 days. Patients in group 2 were divided into three subgroups: subgroup 2A, in which PH procedures were combined with massage of the cervical-collar area and the upper limb area of the affected side; subgroup 2B, where PH gymnastics was carried out in combination with extracorporeal shock wave therapy (ESWT) procedures; subgroup 2C - a comprehensive program including LH procedures, manual massage and shock wave therapy. RESULTS 3 months after the end of the course of rehabilitation measures, patients of all groups showed a significant improvement in scores on the ASES and VAS scales, but there were no reliably significant differences between the results of different groups. CONCLUSION The study indicates that movement therapy is an effective method of rehabilitation for patients with subacromial impingement syndrome, and conducting complex programs in which PH is combined with other rehabilitation methods (massage, shock wave therapy) doesn't have statistically significant advantages over PH alone within a 3-month observation period.
Collapse
|
28
|
The Effect of the Weight and Type of Equipment on Shoulder and Back Muscle Activity in Surface Electromyography during the Overhead Press-Preliminary Report. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22249762. [PMID: 36560129 PMCID: PMC9781216 DOI: 10.3390/s22249762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 12/01/2022] [Accepted: 12/10/2022] [Indexed: 05/14/2023]
Abstract
The overhead press is a multi-joint exercise that has the potential to use a high external load due to the cooperation of many muscle groups. The purpose of this study was to compare the activity of shoulder and back muscles during the overhead press with a kettlebell and a dumbbell. Surface electromyography (EMG) for the anterior and posterior deltoid, upper and lower trapezius, serratus anterior, and spinal erectors was analysed for 20 subjects. Participants performed the four trials of pressing kettlebell and dumbbell, weighted at 6 kg, and 70% of one maximum repetition (1RM) in the sitting position. Statistical analysis was performed using a non-parametric Friedman test and a post-hoc test of Dunn Bonferroni. No significant differences were found in the activation of assessed muscles when comparing dumbbell to kettlebell press trials with the same load (6 kg and 70% of 1RM). However, muscle activity of all muscles except the upper trapezius was always higher for kettlebell pressing. Different center of gravity locations in the kettlebell versus the dumbbell can increase shoulder muscle activity during the overhead press. However, more studies are required to confirm these results.
Collapse
|
29
|
Low educational quality and trustworthiness of YouTube videos by physiotherapists on shoulder joint mobilization techniques: a descriptive study. J Man Manip Ther 2022; 30:334-341. [PMID: 35384791 PMCID: PMC9621245 DOI: 10.1080/10669817.2022.2056319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
INTRODUCTION Physiotherapists and students may be vulnerable to false information and may learn faulty treatment techniques due to inadequate educational quality and uncertainty about sources and trustworthiness of YouTube videos. OBJECTIVE To investigate educational quality, trustworthiness, and content completeness of joint mobilization techniques demonstrating videos available on YouTube. DESIGN This is a descriptive study. METHODS We performed a YouTube search on 1st April 2019, using the keyword 'Maitland joint mobilization technique for shoulder joint'. Three academic physiotherapists independently rated each video for educational quality, trustworthiness, and content completeness using the Global Quality Score, Journal of American Medical Association (JAMA) Benchmark Criteria and joint mobilization content completeness scale, respectively. RESULTS Fifteen videos were included in the study. The median number of views for videos was 1263 (IQR 578-1478), and the median duration was 140 seconds (IQR 71-301 seconds). Most videos had low content quality (87%), poor joint mobilization content completeness (80%), and limited trustworthiness. All videos had low source quality (100%). CONCLUSIONS There is a lack of quality information on shoulder joint mobilization techniques on YouTube, which makes it a limited educational tool for physiotherapists and students.
Collapse
|
30
|
Prognostic potential and pathological validation of a diagnostic application using Raman spectroscopy in the characterization of degenerative changes in the cartilage of the humeral head. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:115002. [PMID: 36352498 PMCID: PMC9646464 DOI: 10.1117/1.jbo.27.11.115002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Accepted: 10/21/2022] [Indexed: 06/16/2023]
Abstract
SIGNIFICANCE Raman spectroscopy is a well-established analytical method in the fields of chemistry, industry, biology, pharmaceutics, and medicine. Previous studies have investigated optical imaging and Raman spectroscopy for osteoarthritis (OA) diagnosis in weight-bearing joints such as hip and knee joints. However, to realize early diagnosis or a curable treatment, it is still challenging to understand the correlations with intrinsic factors or patients’ background. AIM To elucidate the correlation between the Raman spectral features and pathological variations of human shoulder joint cartilage. APPROACH Osteoarthritic cartilage specimens excised from the humeral heads of 14 patients who underwent shoulder arthroplasty were assessed by a confocal Raman microscope and histological staining. The Raman spectroscopic dataset of degenerative cartilage was further analyzed by principal component analysis and hierarchical cluster analysis. RESULTS Multivariate association of the Raman spectral data generated three major clusters. The first cluster of patients shows a relatively high Raman intensity of collagen. The second cluster displays relatively low Raman intensities of proteoglycans (PGs) and glycosaminoglycans (GAGs), whereas the third cluster shows relatively high Raman intensities of PGs and GAGs. The reduced PGs and GAGs are typical changes in OA cartilage, which have been confirmed by safranin–O staining. In contrast, the increased Raman intensities of collagen, PGs, and GAGs may reflect the instability of the cartilage matrix structure in OA patients. CONCLUSIONS The results obtained confirm the correlation between the Raman spectral features and pathological variations of human shoulder joint cartilage. Unsupervised machine learning methods successfully yielded a clinically meaningful classification between the shoulder OA patients. This approach not only has potential to confirm severity of cartilage defects but also to determine the origin of an individual’s OA by evaluating the cartilage quality.
Collapse
|
31
|
In Vivo Anatomical Research by 3D CT Reconstruction Determines Minimum Acromiohumeral, Coracohumeral, and Glenohumeral Distances in the Human Shoulder: Evaluation of Age and Sex Association in a Sample of the Chinese Population. J Pers Med 2022; 12:jpm12111804. [PMID: 36579520 PMCID: PMC9694460 DOI: 10.3390/jpm12111804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 10/14/2022] [Accepted: 10/25/2022] [Indexed: 11/06/2022] Open
Abstract
Accurate measurement of the minimum distance between bony structures of the humeral head and the acromion or coracoid helps advance a better understanding of the shoulder anatomical features. Our goal was to precisely determine the minimum acromiohumeral distance (AHD), coracohumeral distance (CHD), and glenohumeral distance (GHD) in a sample of the Chinese population as an in vivo anatomical analysis. We retrospectively included 146 patients who underwent supine computed tomography (CT) examination of the shoulder joint. The minimum AHD, CHD, and GHD values were quantitatively measured using three-dimensional (3D) CT reconstruction techniques. The correlation between minimum AHD, CHD, and GHD value and age with different sexes was evaluated using Pearson Correlation Coefficient. The mean value of minimum AHD in males was greater than that in females (male 7.62 ± 0.98 mm versus female 7.27 ± 0.86 mm, p = 0.046). The CHD among different sexes differed significantly (male 10.75 ± 2.40 mm versus female 8.76 ± 1.38 mm, p < 0.001). However, we found no statistical differences in GHD with different sexes (male 2.00 ± 0.31 mm versus female 1.96 ± 0.36 mm, p > 0.05). In terms of age correlation, a negative curve correlation existed between age and AHD among the different sexes (male R2 = 0.124, p = 0.030, female R2 = 0.112, p = 0.005). A negative linear correlation was found in CHD among the different sexes (male R2 = 0.164, p < 0.001, female R2 = 0.122, p = 0.005). There were no differences between age and minimum GHD in both sexes. The 3D CT reconstruction model can accurately measure the minimum AHD, CHD, and GHD value in vivo and is worthy of further investigation for standard clinical anatomical assessment. Aging may correlate with AHD and CHD narrowing for both sexes.
Collapse
|
32
|
Synovial chondromatosis of the shoulder in rheumatoid arthritis: A case report and brief review of the literature. Curr Rheumatol Rev 2022:CRR-EPUB-126922. [PMID: 36221868 DOI: 10.2174/1573397118666221011113313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 08/27/2022] [Accepted: 09/09/2022] [Indexed: 11/22/2022]
Abstract
BACKGROUND Synovial chondromatosis is an uncommon benign condition characterized by synovial membrane proliferation and metaplasia. Synovial chondromatosis cases in patients with rheumatoid arthritis have been reported. However, involvement of the glenohumeral joint is rare. CASE PRESENTATION We herein report a case of a rare association of synovial chondromatosis involving the shoulder in a rheumatoid arthritis patient. The symptoms have improved with anti-tumor necrosis factor drugs. Consequently, there was no need for invasive therapy for treating synovial chondromatosis. CONCLUSIONS Synovial chondromatosis can be aggressive and destructive. More trials are needed to establish a better clinical diagnostic strategy and pharmacological management.
Collapse
|
33
|
Effects of a Novel Proprioceptive Rehabilitation Device on Shoulder Joint Position Sense, Pain and Function. MEDICINA (KAUNAS, LITHUANIA) 2022; 58:medicina58091248. [PMID: 36143925 PMCID: PMC9505091 DOI: 10.3390/medicina58091248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 09/01/2022] [Accepted: 09/07/2022] [Indexed: 11/17/2022]
Abstract
Background and Objectives: Shoulder disorders are associated with pain, restricted range of motion and muscular strength, moderate disability and diminished proprioception. This study aimed to compare the effectiveness of an innovative technology-supported and a classical therapist-based proprioceptive training program in addition to conventional physiotherapy, on joint position sense (JPS), pain and function, in individuals with different musculoskeletal shoulder disorders, such as rotator cuff tear, subacromial impingement syndrome and superior labrum anterior and posterior tear. The innovative element of the proprioceptive training programme consists of the use of the Kinesimeter, a device created for both training and assessing shoulder JPS. Materials and Methods: The shoulder JPS test and the DASH outcome questionnaire were applied to fifty-five individuals (28 females, 27 males, mean age 56.31 ± 6.75), divided into three groups: 17 in the conventional physiotherapy group (control group); 19 in the conventional physiotherapy + classical proprioceptive training program group (CPT group); and 19 in the conventional physiotherapy + innovative proprioceptive training program group (KPT group). Assessments were performed before and after a four-week rehabilitation program, with five physiotherapy sessions per week. Results: When baseline and post-intervention results were compared, the value of the shoulder JPS and DASH outcome questionnaire improved significantly for the KPT and CPT groups (all p < 0.001). Both KPT and CPT groups showed statistically significant improvements in JPS, pain and function, compared to the control group which received no proprioceptive training (all p < 0.05). However, the KPT group showed no significant benefits compared to the CPT group. Conclusions: Our findings indicate that using the Kinesimeter device as a novel, innovative proprioceptive training tool has similar effects as the classical proprioceptive training programs among individuals with different non-operated musculoskeletal shoulder disorders such as: rotator cuff tear, subacromial impingement syndrome, and superior labrum anterior and posterior tear.
Collapse
|
34
|
Arthroscopic Latarjet Procedure With 2-Screw Stabilization: Results of Treatment of 156 Cases with a Minimum of 2-Year Follow-Up. Multicenter Study. Ortop Traumatol Rehabil 2022; 24:223-237. [PMID: 36722502 DOI: 10.5604/01.3001.0015.9967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Various arthroscopic stabilization procedures are associated with recurrence rates ranging from 10.8% to 21.1%. Recurrences occur especially in young male patients participating in contact sport activities. Bony defects of the humeral head and the glenoid predispose not only to subsequent dislocations but also to failure of surgical treatment. This is the group where "bony" procedures such as arthroscopic Latarjet are recommended to provide better stability as the primary treatment. MATERIAL AND METHODS Patients with traumatic unidirectional anterior shoulder instability treated from 2009 to 2016 with an arthroscopic Latarjet procedure operated on in two centres. Clinical results, including range of motion, Subjective Shoulder Value and Walch-Duplay score, and postpoperative complications were evaluated. RESULTS 156 patients were available for follow-up at a minimum of 2 years after surgery. The mean follow-up was 4318 months. Mean age at the time of surgery was 27.9 (16-53) years. At final follow-up, 8 cases of recurrent instability were identified, including 6 cases of recurrent dislocation and two cases of recurrent subluxation. Mean Walch-Duplay score increased from 3019 preoperatively to 8316 (p<0.05) at the last follow-up. An average loss of external rotation of 11.8 (0-70) (p<0.05) when compared with the contralateral shoulder was observed at the last follow-up. Mean Subjective Shoulder Value score was 92.89.4%. 8 (5%) patients presented with loss of shoulder stability. 25 (15.8%) patients reported subjective return to sport anxiety. Eleven (7%) patients complained of anterior compartment pain. The total number of revision surgeries was 14 (8.9%). CONCLUSIONS 1. The arthroscopic Latarjet procedure can achieve satisfactory clinical outcomes for the treatment of anterior shoulder instability 2. The rate of complications and recurrence does not increase with time and is comparable at a minimum of 2 years follow-up to early results described in literature.
Collapse
|
35
|
The acute effects of vibratory stimuli during exercise on the sensorimotor control of the shoulder complex: A pilot study. J Back Musculoskelet Rehabil 2022; 35:819-827. [PMID: 34657871 DOI: 10.3233/bmr-210045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Functional stability of the shoulder requires a balance of active forces, passive forces, and control subsystems of the joint complex. Although whole-body vibration enhances shoulder muscle function and proprioception, the impact of vibration on the sensorimotor control of the shoulder joint remains unclear. OBJECTIVE To investigate the acute effect of vibratory stimuli on the sensorimotor control of the shoulder joint. METHODS Fifteen male participants (age, 22.7 ± 2.3 years) were included and performed the exercise in a modified push-up position with partial weight-bearing on a vibration platform with and without vibratory stimuli. The vibration protocol included six sets lasting for 30 s each with a 30-s rest between sets. The main outcome measures included the upper limb static stability test, Upper Quarter Y Balance Test (UQYBT), and electromyography data of the upper limb. RESULTS Vibratory stimuli resulted in an increased UQYBT score (all directions; P< 0.01) and infraspinatus, serratus anterior, and lower trapezius muscle activity (P< 0.05) between pre- and post-exercise versus the control condition. Stabilometric parameters showed no significant interaction between condition and time. CONCLUSIONS Vibratory stimuli could maximize training benefits while limiting injury risk for athletes. Our findings could guide the development of rehabilitation programs for patients with shoulder instability.
Collapse
|
36
|
The efficacy of topical preparations in reducing the incidence of Cutibacterium acnes at the start and conclusion of total shoulder arthroplasty: a randomized controlled trial. J Shoulder Elbow Surg 2022; 31:1115-1121. [PMID: 35183744 DOI: 10.1016/j.jse.2022.01.133] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 01/10/2022] [Accepted: 01/16/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND Preoperative skin preparations for total shoulder arthroplasty (TSA) are not standardized for Cutibacterium acnes eradication. Topical benzyl peroxide (BPO) and benzyl peroxide with clindamycin (BPO-C) have been shown to reduce the bacterial load of C acnes on the skin. Our aim was to investigate whether preoperative application of these topical antimicrobials reduced superficial colonization and deep tissue inoculation of C acnes in patients undergoing TSA. METHODS In a prospective, single-blinded randomized controlled trial, 101 patients undergoing primary TSA were randomized to receive either topical pHisoHex (hexachlorophene [1% triclosan; sodium benzoate, 5 mg/mL; and benzyl alcohol, 5 mg/mL]) (n = 35), 5% BPO (n = 33), or 5% BPO with 1% clindamycin (n = 33). Skin swabs obtained prior to topical application and after topical application before surgery, as well as 3 intraoperative swabs (dermis after incision, on joint capsule entry, and dermis at wound closure), were cultured. The primary outcome was positive culture findings and successful decolonization. RESULTS All 3 topical preparations were effective in decreasing the rate of C acnes. The application of pHisoHex reduced skin colonization by 50%, BPO reduced skin colonization by 73.7%, and BPO-C reduced skin colonization by 81.5%. The topical preparation of BPO-C was more effective in decreasing the rate of C acnes at the preoperative and intraoperative swab time points compared with pHisoHex and BPO (P = .003). Failure to eradicate C acnes with topical preparations consistently resulted in deep tissue inoculation. There was an increase in the C acnes contamination rate on the skin during closure (33%) compared with skin cultures taken at surgery commencement (22%). CONCLUSION Topical application of BPO and BPO-C preoperatively is more effective than pHisoHex in reducing colonization and contamination of the surgical field with C acnes in patients undergoing TSA.
Collapse
|
37
|
Laser-Pointer assisted angle reproduction test (LP-ART): reliability, performance, and correlation with shoulder pain and disability in patients with subacromial pain syndrome. Physiother Theory Pract 2022; 39:1287-1296. [PMID: 35135433 DOI: 10.1080/09593985.2022.2035031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
INTRODUCTION The proprioception plays an important role in the stability of the shoulder joint. However, clinical practice lacks reliable and user-friendly tools. OBJECTIVES To evaluate the intra- and inter-rater reliability of the Laser-Pointer assisted Angle Reproduction Test (LP-ART), to analyze the difference in proprioception between the symptomatic and asymptomatic shoulders, and to investigate if there is a correlation between the LP-ART and the pain intensity assessed by 11-point Numerical Rating Pain Scale (NRPS) and the level of shoulder disability and pain assessed by the Disability Index and Shoulder Pain (SPADI - BR). METHODS Fifty patients (age = 56.2 ± 10.4 years) performed the LP-ART at 90° of shoulder flexion. RESULTS The intra and interrater reliability of the LP-ART measurements was moderate (Intraclass Correlation Coefficient2,3 = 0.41 to 0.65) for both shoulders, symptomatic and asymptomatic. There was no difference in the absolute angular deviation between shoulders (mean difference of 0.4°, P = .581). The absolute angular deviation was not significantly correlated with the pain intensity (rs = 0.007, P = .962) and the SPADI - BR (rs = 0.022, P = .881). CONCLUSION The LP-ART measurement showed moderate reliability in participants with subacromial pain syndrome. The active joint position sense was not different between symptomatic and asymptomatic shoulders, and there was no correlation between proprioception and the pain intensity and shoulder pain and disability level.
Collapse
|
38
|
Evaluating various radiographic methods of shoulder joint damage in patients with rheumatoid arthritis receiving biological disease-modifying antirheumatic drugs. Arch Rheumatol 2021; 36:349-359. [PMID: 34870166 PMCID: PMC8612484 DOI: 10.46497/archrheumatol.2021.8236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Accepted: 07/16/2020] [Indexed: 11/03/2022] Open
Abstract
Objectives This study aims to clarify shoulder joint damage in rheumatoid arthritis patients receiving biological disease-modifying antirheumatic drugs (bDMARDs) and the relationship between joint damage and clinical factors. Patients and methods In this retrospective study conducted between April 2005 and December 2008, 36 shoulders in 19 patients (2 males, 17 females; mean age: 58.9 years; range 42 to 75 years) were evaluated at baseline and two years after the initiation of bDMARD therapy with infliximab (n=14) or etanercept (n=5). Standard anteroposterior radiographs of the shoulder joints were taken at baseline and two years after institution of biological therapy. Structural damage in the shoulder joints was assessed using the Larsen scoring method, the medial displacement index (MDI), and the upward migration index (UMI). Results There was a significant correlation between MDI, UMI, and Larsen grade before biological therapy. Univariate analysis revealed that the disease activity score 28-count erythrocyte sedimentation rate (ESR) at baseline (odds ratio [OR]: 4.298) was associated with progression of MDI. But multivariate logistic regression revealed that there was no association with the progression of MDI. Univariate analysis revealed that ESR at baseline (OR: 0.967) and matrix metalloproteinase-3 (MMP-3) at baseline (OR: 0.996) were associated with the progression of UMI. Multivariate logistic regression revealed that MMP-3 at baseline (OR: 0.994) was independently associated with the progression of UMI. Conclusion Medial displacement index and UMI correlated with the Larsen grade of the shoulder joint strongly and moderately, respectively. This study suggests that MDI and UMI may help to evaluate radiographic progression of damage in shoulder joints in patients on bDMARDs, which is difficult to detect using the Larsen grade.
Collapse
|
39
|
Ultrasound-Guided Treatments for the Painful Shoulder. Curr Med Imaging 2021; 18:693-700. [PMID: 34872482 DOI: 10.2174/1573405617666211206112752] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2021] [Revised: 08/30/2021] [Accepted: 09/27/2021] [Indexed: 11/22/2022]
Abstract
Shoulder pain is an extremely common condition. The painful shoulder may be the result of a wide spectrum of underlying pathological conditions, including calcific tendinopathy of the rotator cuff, subacromial-subdeltoid bursitis, acromioclavicular or glenohumeral arthritis, tenosynovitis of the long biceps tendon, rotator cuff lesions, and many other less common conditions. Ultrasound imaging is an effective tool for the diagnosis and also for the image guidance of treatment of the majority of these conditions. Several ultrasound-guided procedures are effective for pain relief, such as percutaneous irrigation, intra-bursal or intra-articular drugs injection, fluid aspiration, neural block. This review article aims to summarize and discuss the most common treatment possibilities with ultrasound guidance for the painful shoulder.
Collapse
|
40
|
The association between coracoacromial ligament morphology and rotator cuff tears: A cadaveric study. Clin Anat 2021; 35:461-468. [PMID: 34851534 DOI: 10.1002/ca.23814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 11/23/2021] [Accepted: 11/29/2021] [Indexed: 11/11/2022]
Abstract
To determine the association between coracoacromial ligament (CAL) morphology and rotator cuff tears. The present study is a prospective cohort study based on the dissection of 172 shoulders from 86 (46 female, 40 male) formalin embalmed European Caucasian cadavers, with a median age of 82 years. The anatomy of CAL was examined, including its morphology and parametric measurements, while the rotator cuff tendons were inspected for the presence of tears. Gross examination of the CAL in 155 shoulders revealed a variable number of bands as follows: 28 (18%) had one band, 56 (36%) two bands and 71 (46%) three or more bands. Inspection of the rotator cuff tendons showed the presence of tears in 77 (50%) shoulders, of which 37 (24%) were partial and 40 (26%) were full-thickness tears. Statistical analysis showed a significant association (P < 0.05) between CAL band number and the prevalence of a rotator cuff tear. A high proportion of rotator cuff tears were observed in shoulders with two (52%) and three or more CAL bands (56%) compared to single band ligaments (29%). Parametric assessment of the CAL in shoulders with rotator cuff tears showed significantly greater (P < 0.05) attachment widths and ratios, thicker ligament bands, and larger cross-sectional areas compared to the control group. Coracoacromial ligaments with more than a single band have a strong association with rotator cuff tears.
Collapse
|
41
|
Acromion types and morphometric evaluation of painful shoulders. Folia Morphol (Warsz) 2021; 81:991-997. [PMID: 34545562 DOI: 10.5603/fm.a2021.0087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 08/27/2021] [Accepted: 08/30/2021] [Indexed: 12/14/2022]
Abstract
BACKGROUND Due to its many variations, the scapula is among the most frequently examined bones. Especially the acromion can be of different shapes and sizes. Measurements of the morphometric structures in the shoulder joint make it easier to explain the cause of the various shoulder problems. The objective of this study is putting emphasis on the importance of acromion types, os acromiale presence and acromial morphometric measurements in the aetiology and diagnosis of shoulder pain. MATERIALS AND METHODS A retrospective study, based on 100 patients of both genders who presented with the complaints of shoulder pain and underwent magnetic resonance imaging, was conducted. Within this scope, types of acromion, slope of acromion, length of acromion, length of coracoid process, the distance between acromion and coracoid process, lateral acromial angle (LAA), critical shoulder angle (CSA), acromial index (AI) and acromiohumeral distance were measured. The data were analysed considering the gender and acromion types and the presence of os acromiale is investigated. RESULTS The most common acromion was type II (curved) (frequency rate 62%) while the rate of type I (flat) and type III (hooked) acromions were 21% and 17%, respectively. The length of acromion and coracoid process were found to be significantly longer in males, while no significant difference between genders in terms of the distance between acromion and coracoid process were observed. Furthermore, while negative correlation between LAA and AI as well as LAA and CSA were observed; positive correlation between AI and CSA was found. In addition, there was negative correlation between slope of acromion and acromiohumeral distance. Besides, acromiohumeral distance was significantly higher in males. Regarding the presence of os acromiale, it was observed in 3 women out of 59 and 2 men out of 41, which indicated no significant difference between genders. CONCLUSIONS It is evaluated that the morphometric measurement is of importance in contributing clinically in distinguishing the problems that may occur according to gender and acromion types.
Collapse
|
42
|
A Multicenter Randomized Controlled Trial Comparing Single-Row With Double-Row Fixation in Arthroscopic Rotator Cuff Repair: Long-Term Follow-up. Am J Sports Med 2021; 49:3021-3029. [PMID: 34398641 PMCID: PMC8411465 DOI: 10.1177/03635465211029029] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The long-term outcomes of single- versus double-row fixation in arthroscopic rotator cuff repair are not currently known. PURPOSE To compare the treatment effects of the single- versus double-row suture technique in arthroscopic rotator cuff repair of full-thickness tears at 10-year follow-up. STUDY DESIGN Randomized controlled trial; Level of evidence, 1. METHODS Patients were evaluated at 10 years postoperatively. The primary outcome measure was the Western Ontario Rotator Cuff Index (WORC). Secondary outcome measures included the American Shoulder and Elbow Surgeons (ASES) score, Constant score, strength, and incidence of revision surgery. Ultrasound was used to evaluate the rotator cuff to determine repair integrity. Statistical analyses consistent with those of the main trial were conducted. RESULTS Of the original 90 participants, 77 (85%) returned at a mean follow-up of 10 years. At ten year follow-up, the WORC score was higher in the double row group (79.9 [95% CI, 16.2 to 99.1]) compared with the single row group (72.9, [95% CI, 4.3 to 100]), P = .020. From baseline to 2 years, the mean change in WORC scores for the single-row group was -48.5 compared with -40.6 for the double-row group, with a between-group difference of -7.8 (95% CI, -20.4 to 4.7). From 2 to 10 years, the change in WORC scores for the single-row group was 11.5 compared with -0.2 for the double-row group, with a between-group difference of 11.7 (95% CI, -0.7 to 24.3). From baseline to 10 years, the mean between-group difference was 3.9 (95% CI, -7.8 to 15.6). Similarly, a decrease in ASES scores was observed between 2 and 10 years for the single-row group (9.2 [95% CI, 0.9 to 17.5]; P = .029), with a nonsignificant decrease in ASES scores for the double-row group (6.2 [95% CI, -3.2 to 15.6]; P = .195) as well as a decrease in Constant scores for both the single- (9.5 [95% CI, 1.4 to 17.5]; P = .020) and double-row (14.4 [95% CI, 5.6 to 23.3]; P = .001) groups. Overall, 3 participants developed a full-thickness tear after 2 years: 2 from the double-row group and 1 from the single-row group. One participant from each study group underwent revision surgery after the 2-year time point. CONCLUSION A statistically significant (but likely not clinically important) difference in WORC scores was seen at 10-year follow-up in favor of double-row fixation. Between baseline and 10-year follow-up, a decrease in most outcome scores was observed in both the single- and the double-row groups. REGISTRATION NCT00508183 (ClinicalTrials.gov identifier).
Collapse
|
43
|
[Interpretation of 2020 American Academy of Orthopaedic Surgeons (AAOS) on the Management of Glenohumeral Joint Osteoarthritis Evidence-Based Clinical Practice Guideline]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2021; 35:935-940. [PMID: 34387417 DOI: 10.7507/1002-1892.202103088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
The 2020 Management of Glenohumeral Joint Osteoarthritis Evidence-Based Clinical Practice Guideline which was prepared by the American Academy of Orthopaedic Surgeons (AAOS) were publicated on October 2020. The guideline involves the following 8 chapters: drug therapy and injectable biologics, physical therapy and non-surgical treatments, radiographs, prognostic factors, surgical treatments, intraoperative hemostasis measure (tranexamic acid), management of supraspinatus tears, multimodal pain management and discharge. In this paper, the guideline is interpreted to provide cutting-edge information for domestic glenohumeral joint osteoarthritis researchers.
Collapse
|
44
|
Impact of smoking on pain and function in rotator cuff repair: A prospective 5-year cohort follow-up of 1383 patients. ANZ J Surg 2021; 91:2153-2158. [PMID: 34268853 DOI: 10.1111/ans.17062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Revised: 05/23/2021] [Accepted: 06/23/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND This multicentre cohort study investigates the effect of smoking on the outcome of rotator cuff repair (RCR), with attention to age at presentation for surgery, pre-operative and post-operative pain and function and intra-operative findings. METHODS Patient information was collected pre-operatively, including Flex Shoulder Function (Flex SF) and visual analogue scale pain, then at 6 months, 1, 2 and 5 years post-operatively. Intra-operative technical data were collected by the operating surgeon. Current smokers were classified by daily cigarette consumption. RESULTS A total of 1383 RCRs in as many patients were included with an 84% 5-year follow-up. Smokers were on average 6.7 years younger than non-smokers (51.8 vs. 58.5, P < 0.001). There was no difference in intra-operatively assessed tear size both in anteroposterior dimension (P = 0.5) and retraction (P = 0.9). Pre-operative Flex SF score in smokers was below that of non-smokers (23.0 vs. 24.5, P = 0.002) and at 6 months (P = 0.02) but no different at 5 years (P = 0.7). Pain scores were higher in smokers than non-smokers both pre-operatively (5.34 vs. 4.67, P < 0.001) and up to 2 years (P < 0.001) but not at 5 years (P = 0.073). CONCLUSION Smokers undergoing RCR were younger than non-smokers, and had worse pre-operative pain scores and shoulder function. Poorer post-operative function persisted to 6 months, and with higher reported pain to 2 years in smokers. However, at 5-year follow-up, patient-reported outcomes were not affected by smoking status.
Collapse
|
45
|
The humeral head: A review of the blood supply and possible link to osteonecrosis following rotator cuff repair. J Anat 2021; 239:973-982. [PMID: 34164802 PMCID: PMC8546514 DOI: 10.1111/joa.13496] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Revised: 06/03/2021] [Accepted: 06/09/2021] [Indexed: 11/28/2022] Open
Abstract
Trauma, corticosteroid therapy and metabolic diseases are well established aetiologies of humeral head osteonecrosis; however, there is increasing evidence that arthroscopic rotator cuff surgery may be another possible cause. One of the reasons is that there may be inadvertent damage to the arterial blood supply to the humeral head during surgical intervention. The blood supply to the humeral head displays large amounts of variation with regard to origin, course and distribution. Therefore, to shed light on the pathogenesis, the blood supply of the humeral head is reviewed together with a summary of all reported cases of osteonecrosis of the humeral head that occurred following rotator cuff repair. Inconsistencies with regard to terminologies used and contradictions concerning arterial contributions from the anterior circumflex humeral artery and the posterior circumflex humeral artery towards humeral head supply are addressed. Moreover, variations in the course of the anterior circumflex humeral artery and its branches are summarized. The vascular anatomy of the humeral head is clinically relevant due to the close relationship of these blood vessels with the surgical repair sites for rotator cuff surgery and biceps tenotomies or tenodesis procedures. Potential sites of disruption of blood supply following arthroscopic rotator cuff surgery are discussed. Detailed knowledge of the course of the arteries supplying the humeral head may help to minimize the risk of vascular injury and subsequent osteonecrosis. Given the great interindividual variations of vascular anatomy, imaging procedures preceding arthroscopic rotator cuff surgery may be advisable.
Collapse
|
46
|
Correlation of Ultrasound Findings With Clinical Stages and Impairment in Adhesive Capsulitis of the Shoulder. Orthop J Sports Med 2021; 9:23259671211003675. [PMID: 33997079 PMCID: PMC8113659 DOI: 10.1177/23259671211003675] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Accepted: 12/15/2020] [Indexed: 11/22/2022] Open
Abstract
Background: Ultrasound is an essential tool for diagnosing shoulder disorders. However, the role of ultrasound in assessing and diagnosing adhesive capsulitis has not been fully studied. Purpose: To evaluate the ultrasound features of adhesive capsulitis and estimate the correlations between clinical impairment and ultrasound parameters. Study Design: Case series; Level of evidence, 4. Methods: A total of 61 patients with clinically diagnosed unilateral adhesive capsulitis were retrospectively reviewed using high-resolution ultrasound. To compare ultrasound parameters, we performed ultrasound examinations on both affected and unaffected shoulders. Ultrasound parameters, including thickness of the coracohumeral ligament (CHL), rotator interval (RI), axillary recess (AR), hypervascularity of the RI, and effusion of the long head of the biceps tendon sheath, were measured. Passive range of motion (PROM), visual analog scale for pain, and the Shoulder Pain and Disability Index were used for clinical assessment. Results: The CHL, the RI, and the AR in affected shoulders were significantly thicker than in unaffected shoulders (P < .05). CHL thickness in affected shoulders was significantly correlated with PROM limitation, which included forward elevation, abduction, external rotation (ER), and internal rotation (IR) (P < .05). AR thickness correlated with passive forward elevation limitation and passive IR limitation (P < .05). The CHL was significantly thicker in stage 2 compared with stage 1, and the RI was thicker in stage 2 compared with stage 3. The diagnostic cutoff values for adhesive capsulitis were 2.2 mm for CHL thickness (77% sensitivity, 91.8% specificity) and 4 mm for AR thickness (68.9% sensitivity, 90.2% specificity). Conclusion: The ultrasound parameters associated with structural changes were correlated with clinical characteristics of adhesive capsulitis. Thickened CHL, RI, and AR were observed in affected shoulders. The cutoff values of 2.2 mm for CHL thickness and 4 mm for AR thickness can be used as cutoff diagnostic values for adhesive capsulitis.
Collapse
|
47
|
[Mirror-type rehabilitation training with dynamic adjustment and assistance for shoulder joint]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2021; 38:351-360. [PMID: 33913296 PMCID: PMC9927699 DOI: 10.7507/1001-5515.202001053] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Revised: 11/04/2020] [Indexed: 11/03/2022]
Abstract
The real physical image of the affected limb, which is difficult to move in the traditional mirror training, can be realized easily by the rehabilitation robots. During this training, the affected limb is often in a passive state. However, with the gradual recovery of the movement ability, active mirror training becomes a better choice. Consequently, this paper took the self-developed shoulder joint rehabilitation robot with an adjustable structure as an experimental platform, and proposed a mirror training system completed by next four parts. First, the motion trajectory of the healthy limb was obtained by the Inertial Measurement Units (IMU). Then the variable universe fuzzy adaptive proportion differentiation (PD) control was adopted for inner loop, meanwhile, the muscle strength of the affected limb was estimated by the surface electromyography (sEMG). The compensation force for an assisted limb of outer loop was calculated. According to the experimental results, the control system can provide real-time assistance compensation according to the recovery of the affected limb, fully exert the training initiative of the affected limb, and make the affected limb achieve better rehabilitation training effect.
Collapse
|
48
|
Diagnostic Value of Frequently Implemented Provocative Tests in the Assessment of Shoulder Pain-A Glimpse of Current Practice. ACTA ACUST UNITED AC 2021; 57:medicina57030221. [PMID: 33804384 PMCID: PMC7999976 DOI: 10.3390/medicina57030221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2021] [Revised: 02/24/2021] [Accepted: 02/26/2021] [Indexed: 11/16/2022]
Abstract
Initial evaluation of chronic shoulder disability is a diagnostic challenge due to the anatomic complexity of the shoulder joints. For this purpose, several diagnostic tools utilizing provocative testing exist, but only a few have a reliable basis for their diagnostic value. Therefore, objectively determining the predictive value of these tests in identifying the precise anatomical source for disability—subacromial, intraarticular or other—is essential in order to proceed with further imaging evaluations for final objective diagnoses. Using validated clusters of provocative tests should improve their diagnostic values.
Collapse
|
49
|
[Application of suspensory external fixation technique in treatment of proximal humeral fracture]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2021; 35:144-148. [PMID: 33624464 DOI: 10.7507/1002-1892.202009016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To investigate the effectiveness of suspensory external fixation technique in treatment of proximal humeral fractures. Methods Between August 2013 and October 2018, 14 patients with proximal humeral fractures were treated with suspensory external fixation technique. There were 10 males and 4 females with an average age of 55.9 years (range, 43-76 years). There were 10 cases of falling injury and 4 cases of traffic accident injury. Among them, there were 9 cases of Neer type Ⅲ and 5 cases of Neer type Ⅳ. The time from injury to operation was 3-7 days (mean, 4.6 days). Nine cases were complicated with osteoporosis. The preoperative visual analogue scale (VAS) score was 6.1±1.2. The effectiveness was comprehensively evaluated by hospital stay, fracture healing time, removal time of external fixator, postoperative complications, VAS score, and Neer score of shoulder joint function. Results All operations were successfully completed, and the hospital stay was 6-14 days, with an average of 9.4 days. All the incisions healed by first intention, and no infection or other complications occurred. All patients were followed up 16-60 months (mean, 35.4 months). X-ray films examination showed that all fractures healed, the healing time was 4-7 months (mean, 4.9 months). The removal time of external fixator was 5-8 months (mean, 6.3 months). VAS scores were 1.5±0.8 at 1 month after operation and 1.0±0.9 at last follow-up, both of which were significantly improved when compared with preoperative score, the differences were significant between different time points ( P<0.05). Neer score of shoulder joint function was 75-100 (mean, 91.1); 9 cases were excellent, 4 cases were good, and 1 case was fair. The excellent and good rate was 92.9%. During follow-up, there was no adverse events such as acromion impingement, nonunion, or pseudoarthrosis. Conclusion For proximal humeral fractures, the suspensory external fixation technique is a simple and reliable treatment method that can significantly improve joint function.
Collapse
|
50
|
Reverse total shoulder arthroplasty compared to stemmed hemiarthroplasty for proximal humeral fractures: a registry analysis of 5946 patients. J Shoulder Elbow Surg 2020; 29:2538-2547. [PMID: 32684280 DOI: 10.1016/j.jse.2020.04.005] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Revised: 03/28/2020] [Accepted: 04/01/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND There is an increasing trend toward the use of reverse total shoulder arthroplasty (RTSA) over stemmed hemiarthroplasty (HA) for the management of proximal humeral fractures. There are limited data available comparing the revision rates for RTSA and HA in the setting of a fracture. The aim of this study was to compare the revision rates for RTSA and HA when used for the treatment of a fracture and to analyze the effect of demographics and prosthesis fixation on these revision rates. METHODS Data obtained from the Australian Orthopaedic Association National Joint Replacement Registry from April 16, 2004, to December 31, 2017, included all procedures for primary diagnosis proximal humeral fracture. The analyses were performed using Kaplan-Meier estimates of survivorship and hazard ratios from Cox proportional hazards models. RESULTS Over the study period, there were 3049 (51%) RTSA and 2897 (49%) HA procedures. The cumulative percent revision rate at 9 years was lower for the RTSA than for the HA: 7.0% (95% confidence interval [CI], 4.8-10.1) compared with 11.7% (95% CI, 10.3-13.2). Between 0 and 6 months, the HA had a significantly lower revision rate than the RTSA (hazard ratio, 0.50; 95% CI, 0.34-0.72; P < .001). Between 6 month and 3 years, the HA had a significantly higher revision rate. For the RTSA, males have a significantly higher rate of revision compared with females. There is a higher rate of early revision due to instability in younger persons (55-64) and males. For both RTSA and HA, cemented prostheses have lower revision rates compared with cementless prostheses. CONCLUSIONS RTSA has a significantly lower revision rate compared with HA for the treatment of proximal humeral fractures in females. Younger patients (<65) and males are at risk of early revision secondary to instability. In these patient groups, either alternatives to RTSA or further attention to fixation of tuberosities and shoulder rehabilitation may be indicated.
Collapse
|