1
|
Da Rin G, Seghezzi M, Padoan A, Pajola R, Bengiamo A, Di Fabio AM, Dima F, Fanelli A, Francione S, Germagnoli L, Lorubbio M, Marzoni A, Pipitone S, Rolla R, Bagorria Vaca MDC, Bartolini A, Bonato L, Sciacovelli L, Buoro S. Multicentric evaluation of the variability of digital morphology performances also respect to the reference methods by optical microscopy. Int J Lab Hematol 2022; 44:1040-1049. [PMID: 35916349 DOI: 10.1111/ijlh.13943] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Accepted: 07/04/2022] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Despite the important diagnostic role of peripheral blood morphology, cell classification is subjective. Automated image-processing systems (AIS) provide more accurate and objective morphological evaluation. The aims of this multicenter study were the evaluation of the intra and inter-laboratory variation between different AIS in cell pre-classification and after reclassification, compared with manual optical microscopy, the reference method. METHODS Six peripheral blood samples were included in this study, for each sample, 70 May-Grunwald and Giemsa stained PB smears were prepared from each specimen and 10 slides were delivered to the seven laboratories involved. Smears were processed by both optical microscopy (OM) and AIS. In addition, the assessment times of both methods were recorded. RESULTS Within-laboratory Reproducibility ranged between 4.76% and 153.78%; between-laboratory Precision ranged between 2.10% and 82.2%, while Total Imprecision ranged between 5.21% and 20.60%. The relative Bland Altman bias ranged between -0.01% and 20.60%. The mean of assessment times were 326 ± 110 s and 191 ± 68 s for AIS post reclassification and OM, respectively. CONCLUSIONS AIS can be helpful when the number of cell counted are low and can give advantages in terms of efficiency, objectivity and time saving in the morphological analysis of blood cells. They can also help in the interpretation of some morphological features and can serve as learning and investigation tools.
Collapse
Affiliation(s)
- Giorgio Da Rin
- Laboratory Medicine, IRCCS Ospedale Policlinico San Martino, Genoa, Italy
| | - Michela Seghezzi
- Clinical Chemistry Laboratory, Papa Giovanni XXIII Hospital, Bergamo, Italy
| | - Andrea Padoan
- Department of Laboratory Medicine, University-Hospital of Padova, Padova, Italy
| | - Rachele Pajola
- UOC Clinical Chemistry Laboratory, Ospedali Riuniti Padova Sud Schiavonia, Veneto, Italy
| | - Anna Bengiamo
- Clinical Chemistry and Hematology Laboratory, University Hospital of Parma, Parma, Italy
| | | | - Francesco Dima
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| | - Alessandra Fanelli
- Department of General Laboratory, Careggi University Hospital, Florence, Italy
| | - Sara Francione
- Department of Clinical Chemistry and Microbiology, Novara, Italy
| | - Luca Germagnoli
- Clinical Chemistry Laboratory, IRCCS Humanitas, Milan, Italy
| | - Maria Lorubbio
- Department of Laboratory and Transfusional Medicine, Careggi University Hospital, Florence, Italy
| | | | - Silvia Pipitone
- Clinical Chemistry and Hematology Laboratory, University Hospital of Parma, Parma, Italy
| | - Roberta Rolla
- Department of Health Sciences, University of Eastern Piedmont 'Amedeo Avogadro', Novara, Italy
| | | | | | | | - Laura Sciacovelli
- Department of Laboratory Medicine, University-Hospital of Padova, Padova, Italy
| | - Sabrina Buoro
- Regional Reference Center for the Quality of Laboratory Medicine Services, Milan, Italy
| | | |
Collapse
|
2
|
Yamamoto Y, Fujita M, Watanabe S, Yamaga H, Wakabayashi K, Tahara Y, Horie N, Fujimoto K, Takeuchi K, Kamiya K, Kawakami T, Kojima K, Sozu T, Kojima H, Kasahara T, Ono A. Within- and between-laboratory reproducibility and predictive capacity of amino acid derivative reactivity assay (ADRA) using a 0.5 mg/mL test chemical solution: Results of the study for reproducibility confirmation implemented in five participating laboratories. J Appl Toxicol 2022; 42:1078-1090. [PMID: 35043433 DOI: 10.1002/jat.4279] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 12/01/2021] [Accepted: 12/01/2021] [Indexed: 01/03/2023]
Abstract
The amino acid derivative reactivity assay (ADRA) is an in chemico alternative assay for skin sensitization listed in OECD test guideline 442C. ADRA evaluates the reactivity of sensitizers to proteins, which is key event 1 in the skin sensitization adverse outcome pathway. Although the current key event 1 evaluation method is a simple assay that evaluates nucleophile and test chemical reactivity, mixtures of unknown molecular weights cannot be evaluated because a constant molar ratio between the nucleophile and test chemical is necessary. In addition, because the nucleophile is quantified by HPLC, the frequency of co-eluting the test chemical and nucleophile increases when measuring multi-component mixtures. To solve these issues, test conditions have been developed using a 0.5 mg/mL test chemical solution and fluorescence-based detection. Since the practicality of these methods has not been substantiated, a validation test to confirm reproducibility was conducted in this study. The 10 proficiency substances listed in the ADRA guidelines were tested three times at five different laboratories. The results of both within- and between-laboratory reproducibility were 100%, and the results of ultraviolet- and fluorescence-based measurements were also consistent. In addition to the proficiency substances, a new positive control, squaric acid diethyl ester, was tested three times at the five laboratories. The results showed high reproducibility with N-(2-(1-naphthyl)acetyl)-l-cysteine depletion of 37%-52% and α-N-(2-(1-naphthyl)acetyl)-l-lysine depletion of 99%-100%. Thus, high reproducibility was confirmed in both evaluations of the 0.5 mg/mL test chemical and the fluorescence-based measurements, validating the practicability of these methods.
Collapse
Affiliation(s)
- Yusuke Yamamoto
- Safety Evaluation Center, Fujifilm Corporation, Kanagawa, Japan
| | - Masaharu Fujita
- Safety Evaluation Center, Fujifilm Corporation, Kanagawa, Japan
| | - Shinichi Watanabe
- Safety Science Research Laboratories, Lion Corporation, Kanagawa, Japan
| | - Hiroaki Yamaga
- Safety Science Research Laboratories, Lion Corporation, Kanagawa, Japan
| | - Koji Wakabayashi
- Chemical Safety Department, Mitsui Chemicals, Inc., Chiba, Japan
| | - Yu Tahara
- Chemical Safety Department, Mitsui Chemicals, Inc., Chiba, Japan
| | - Nobuyuki Horie
- Environmental Health Science Laboratory, Sumitomo Chemical Co., Ltd., Osaka, Japan
| | - Keiichi Fujimoto
- Environmental Health Science Laboratory, Sumitomo Chemical Co., Ltd., Osaka, Japan
| | - Kazuya Takeuchi
- Biological Research Laboratories, Nissan Chemical Corporation, Saitama, Japan
| | - Kohei Kamiya
- Biological Research Laboratories, Nissan Chemical Corporation, Saitama, Japan
| | - Tsuyoshi Kawakami
- Division of Environmental Chemistry, National Institute of Health Sciences, Kanagawa, Japan
| | | | - Takashi Sozu
- Faculty of Engineering, Tokyo University of Science, Tokyo, Japan
| | - Hajime Kojima
- Biological safety Research Center, Division of Risk Assessment, National Institute of Health Sciences, Kanagawa, Japan
| | | | - Atsushi Ono
- Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Division of Pharmaceutical Sciences, Okayama University, Okayama, Japan
| |
Collapse
|