1
|
Maňásek V, Charvát J, Chovanec V, Sirotek L, Linke Z, Tuček Š, Šenkyřík M, Michálek P, Polák M, Fricová J, Daniš L, Šeflová L, Lisová K, Douglas M. Indications for venous access in oncology - recommendations of national professional societies and current state in the Czech Republic. Klin Onkol 2021; 34:192-201. [PMID: 34362255 DOI: 10.48095/ccko2021192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND The aim of the paper is to present the current recommendations and indications of venous access in oncology which reflect and recognize the opinions of national and international professional societies. It focuses exclusively on the indications of intravenous catheter placement for anticancer treatment, such as medium-term and long-term venous accesses. MATERIALS AND METHODS The survey results obtained from a national questionnaire of 24 oncology centers identified the current situation in the Czech Republic. There were evaluated relevant data on the number of and the criteria for the introduction of venous accesses provided by physicians. Comparisons were made between current oncological practice and recommendations provided by evidence-based medicine. RESULTS At each center surveyed in the Czech Republic, an average of 130 ports and 80 permanent implanted central catheters are introduced annually. The ports are increasingly indicated, with over a half of the centers surveyed introducing ports to more than 100 patients a year, with four centers introducing a total of 1,600 ports annually. In all centers, the decision for venous access is made by an oncologist. However, most procedures are performed by a doctor of another specialization, most often by a surgeon, a radiologist or an anesthesiologist. More than a half of the indications for venous access placement result from poor peripheral venous system or complications of parenteral therapy, not from comprehensive assessment prior to the initiation of the therapy. CONCLUSION Based on our findings, we developed general indications and recommendations for venous access to cancer patients which represent the consensus of an interdisciplinary team of specialists, predominantly from the committee of professional societies - the Society for Ports and Permanent Catheters, the Working Group of Nutritional Care in Oncology of the Czech Oncological Society and the Society of Clinical Nutrition and Intensive Metabolic Care. The number of introduced venous access catheters remains insufficient to meet the needs in the Czech Republic, which necessitates increased awareness and possibilities for safe drug administration.
Collapse
|
2
|
Chou PL, Fu JY, Cheng CH, Chu Y, Wu CF, Ko PJ, Liu YH, Wu CY. Current port maintenance strategies are insufficient: View based on actual presentations of implanted ports. Medicine (Baltimore) 2019; 98:e17757. [PMID: 31689833 PMCID: PMC6946320 DOI: 10.1097/md.0000000000017757] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 09/26/2019] [Accepted: 10/02/2019] [Indexed: 12/28/2022] Open
Abstract
Nursing staff play a crucial role in maintaining a functional port. Nursing guidelines recommend standard maintenance with 10 ml irrigation without consideration for variations among patients and individual nursing staff. The aim of this study is to identify the efficacy of the current maintenance strategy and analyze the correlation between complications and actual port presentations, based on disassembled intravenous ports after removal from patients. We attempt to organize the information and propose a definite maintenance strategy.After treatment completion, or due to complications, 434 implanted intravenous ports were removed from patients. All ports were deconstructed to observe their actual presentations and were then analyzed in conjunction with medical records. The correlation between complications and actual presentations was analyzed.From March 2012 to December 2017, 434 implanted intravenous ports were removed from oncology patients after completion of treatment or catheter related complications. From the view of maintenance related presentations, injection chamber blood clot was highly correlated with chemotherapy completion (P < .001) and malfunction (P = .005), while tip blood clot (P = .043) was related with chemotherapy completion and catheter fibrin (P = .015) was related to malfunction. From the view of structure related presentations, broken catheter integrity was correlated to chemotherapy completion (P = .007), fracture (P < .001), and malfunction (P = .008). Compression groove was related to chemotherapy completion (P = .03) and broken catheter at protruding stud was related to fracture (P = .04), while diaphragm rupture was correlated to chemotherapy completion (P = .048) and malfunction. (P < .001).Current port maintenance is insufficient for ideal port maintenance, whereby maintenance-related presentations, including tip clot, catheter fibrin, and injection chamber blood clot were identified. We propose a recommended maintenance strategy based on our findings. Structure-related presentations, including broken catheter integrity, broken catheter at protruding stud and diaphragm rupture were seen in patients with longer implantation period. Removal of the implanted port may be considered after 5 years if no disease relapse is noted.
Collapse
Affiliation(s)
- Pin-Li Chou
- Chang Gung University, Taiwan
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Jui-Ying Fu
- Chang Gung University, Taiwan
- Division of Chest, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Chia-Hui Cheng
- Laboratory of Cardiovascular Physiology, Department of Medical Research and Development, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Yen Chu
- Chang Gung University, Taiwan
- Laboratory of Cardiovascular Physiology, Department of Medical Research and Development, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Ching-Feng Wu
- Chang Gung University, Taiwan
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Po-Jen Ko
- Chang Gung University, Taiwan
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Yun-Hen Liu
- Chang Gung University, Taiwan
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Ching-Yang Wu
- Chang Gung University, Taiwan
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou, Taiwan
| |
Collapse
|
3
|
Slater K, Cooke M, Scanlan E, Rickard CM. Hand hygiene and needleless connector decontamination for peripheral intravenous catheter care-time and motion observational study. Am J Infect Control 2019; 47:1017-1019. [PMID: 30850248 DOI: 10.1016/j.ajic.2019.01.022] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Revised: 01/28/2019] [Accepted: 01/28/2019] [Indexed: 11/27/2022]
Abstract
Good hand hygiene and "scrub the hub" practices are important to prevent bloodstream infections. This observational study (n = 108) found high compliance with "scrubbing the hub," although scrub time was shorter than the recommended duration (average 6.1 seconds). Compliance with hand hygiene before medication preparation (33%) and before medication administration (43%) showed room for improvement compared with postadministration (65%), the emergency setting and glove use were associated with poorer compliance (P < .01).
Collapse
Affiliation(s)
- Karen Slater
- Princess Alexandra Hospital, Brisbane, Australia; School of Nursing and Midwifery, Griffith University, Brisbane, Australia.
| | - Marie Cooke
- Alliance for Vascular Access Teaching & Research Group, Menzies Health Institute Queensland, Griffith University, Brisbane, Australia
| | - Emma Scanlan
- Princess Alexandra Hospital, Brisbane, Australia
| | - Claire M Rickard
- Alliance for Vascular Access Teaching & Research Group, Menzies Health Institute Queensland, Griffith University, Brisbane, Australia
| |
Collapse
|
4
|
Maltoni G, Zioutas M, Zucchini S, Pession A. Using an injection port helps improve metabolic control and compliance to a strict basal-bolus regimen in children and adolescents with type 1 diabetes. J Diabetes 2018; 10:686-688. [PMID: 29604174 DOI: 10.1111/1753-0407.12665] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2017] [Revised: 03/01/2018] [Accepted: 03/27/2018] [Indexed: 11/27/2022] Open
Affiliation(s)
- Giulio Maltoni
- Unit of Pediatrics, Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| | - Maximiliano Zioutas
- Unit of Pediatrics, Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| | - Stefano Zucchini
- Unit of Pediatrics, Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| | - Andrea Pession
- Unit of Pediatrics, Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| |
Collapse
|
5
|
Kleidon T, Ullman AJ, Zhang L, Mihala G, Chaseling B, Schoutrop J, Rickard CM. How Does Your PICCOMPARE? A Pilot Randomized Controlled Trial Comparing Various PICC Materials in Pediatrics. J Hosp Med 2018; 13:517-525. [PMID: 29649341 DOI: 10.12788/jhm.2911] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Despite the popularity of peripherally inserted central catheters (PICCs), recent literature highlights their potential injurious complications. Innovative PICC materials have been developed to prevent thrombosis and infection formation (Endexo®) and antireflux valves to prevent occlusion (pressure-activated safety valve®). No large randomized controlled trial has assessed these technologies. Our primary aim was to evaluate the feasibility of a large randomized controlled efficacy trial of PICC materials and design to reduce PICC complication in pediatrics. METHODS A randomized controlled feasibility trial was undertaken at the Lady Cilento Children's Hospital in South Brisbane, Australia, between March 2016 and November 2016. Consecutive recruitment of 150 pediatric participants were randomly assigned to receive either (1) polyurethane PICC with a clamp or (2) BioFlo® PICC (AngioDynamics Inc, Queensbury, NY). Primary outcomes were trial feasibility, including PICC failure (thrombosis, occlusion, infection, breakage, or dislodgement). Secondary outcomes were PICC complications during use. RESULTS Protocol feasibility was established, including staff and patient acceptability, timely recruitment, no missing primary outcome data, and 0% attrition. PICC failure was 22% (16 of 74, standard care) and 11% (8 of 72, BioFlo®) corresponding to 12.6 and 7.3 failures per 1000 hours (risk ratio 0.58; 95% confidence interval, 0.21-1.43; P = .172). PICC failures were primarily due to thrombosis (standard care 7% versus BioFlo® 3%) and complete occlusion (standard care 7% versus BioFlo® 1%). No blood stream infections occurred. Significantly fewer patients with BioFlo® had PICC complications during use (15% vs 34%; P = .009). CONCLUSIONS BioFlo® PICCs appear potentially safer for pediatrics than traditional standard care PICCs with a clamp. Further research is required to definitively identify clinical, cost-effective methods to prevent PICC failure and improve reliability.
Collapse
Affiliation(s)
- Tricia Kleidon
- Children's Health Queensland, Lady Cilento Children's Hospital, South Brisbane, Queensland, Australia.
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute Queensland, Nathan Campus, Queensland, Australia
| | - Amanda J Ullman
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute Queensland, Nathan Campus, Queensland, Australia
- School of Nursing and Midwifery, Griffith University, Nathan Campus, Queensland, Australia
| | - Li Zhang
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute Queensland, Nathan Campus, Queensland, Australia
| | - Gabor Mihala
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute Queensland, Nathan Campus, Queensland, Australia
- Centre for Applied Health Economics, Menzies Health Institute Queensland, Nathan Campus, Queensland, Australia
- School of Medicine, Griffith University, Queensland, Australia
| | - Brett Chaseling
- Children's Health Queensland, Lady Cilento Children's Hospital, South Brisbane, Queensland, Australia
- University of Queensland, St. Lucia, Queensland, Australia
| | - Jason Schoutrop
- Children's Health Queensland, Lady Cilento Children's Hospital, South Brisbane, Queensland, Australia
- University of Queensland, St. Lucia, Queensland, Australia
| | - Claire M Rickard
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute Queensland, Nathan Campus, Queensland, Australia
- School of Nursing and Midwifery, Griffith University, Nathan Campus, Queensland, Australia
| |
Collapse
|
6
|
Alexandrou E, Ray-Barruel G, Carr PJ, Frost SA, Inwood S, Higgins N, Lin F, Alberto L, Mermel L, Rickard CM. Use of Short Peripheral Intravenous Catheters: Characteristics, Management, and Outcomes Worldwide. J Hosp Med 2018; 13. [PMID: 29813140 DOI: 10.12788/jhm.3039] [Citation(s) in RCA: 186] [Impact Index Per Article: 31.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Peripheral intravenous catheter (PIVC) use in health care is common worldwide. Failure of PIVCs is also common, resulting in premature removal and replacement. OBJECTIVE To investigate the characteristics, management practices, and outcomes of PIVCs internationally. SETTING/PATIENTS Cross-sectional study. Hospitalized patients from rural, regional, and metropolitan areas internationally. MEASUREMENTS Hospital, device, and inserter characteristics were collected along with assessment of the catheter insertion site. PIVC use in different geographic regions was compared. RESULTS We reviewed 40,620 PIVCs in 51 countries. PIVCs were used primarily for intravenous medication (n = 28,571, 70%) and predominantly inserted in general wards (n = 22,167, 55%). Two-thirds of all devices were placed in non-recommended sites such as the hand, wrist, or antecubital veins. Nurses inserted most PIVCs (n = 28,575, 71%); although there was wide regional variation (26% to 97%). The prevalence of iIn this study, we found that many PIVCs were placed in areas of flexion, were symptomatic or idle, had suboptimal dressings, or lacked adequate documentation. This suggests inconsistency between recommended management guidelines for PIVCs and current practice.dle PIVCs was 14% (n = 5,796). Overall, 10% (n = 4,204) of PIVCs were painful to the patient or otherwise symptomatic of phlebitis; a further 10% (n = 3,879) had signs of PIVC malfunction; and 21% of PIVC dressings were suboptimal (n = 8,507). Over one-third of PIVCs (n = 14,787, 36%) had no documented daily site assessment and half (n = 19,768, 49%) had no documented date and time of insertion. CONCLUSIONS In this study, we found that many PIVCs were placed in areas of flexion, were symptomatic or idle, had suboptimal dressings, or lacked adequate documentation. This suggests inconsistency between recommended management guidelines for PIVCs and current practice.
Collapse
Affiliation(s)
- Evan Alexandrou
- Western Sydney University, New South Wales, Australia.
- Department of Intensive Care, Liverpool Hospital, New South Wales, Sydney, New South Wales, Australia
- Department of Intensive Care, Liverpool Hospital, New South Wales, Sydney, New South Wales, Australia
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute, Griffith University, Brisbane, Queensland, Australia
- Centre for Applied Nursing Research & Ingham Institute for Applied Medical Research, South Western Sydney Local Health District, South Western Sydney Clinical School, University of New South Wales, New South Wales, Australia
| | - Gillian Ray-Barruel
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute, Griffith University, Brisbane, Queensland, Australia
- National Centre of Research Excellence in Nursing, Griffith University, Brisbane, Queensland, Australia
| | - Peter J Carr
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute, Griffith University, Brisbane, Queensland, Australia
- National Centre of Research Excellence in Nursing, Griffith University, Brisbane, Queensland, Australia
- The University of Western Australia, Perth, Western Australia, Australia
| | - Steven A Frost
- Western Sydney University, Sydney, New South Wales, Australia
- Department of Intensive Care, Liverpool Hospital, New South Wales, Sydney, New South Wales, Australia
- Centre for Applied Nursing Research & Ingham Institute for Applied Medical Research, South Western Sydney Local Health District, South Western Sydney Clinical School, University of New South Wales, New South Wales, Australia
| | | | - Niall Higgins
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute, Griffith University, Brisbane, Queensland, Australia
- Queensland University of Technology, Brisbane, Queensland, Australia
| | - Frances Lin
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute, Griffith University, Brisbane, Queensland, Australia
| | - Laura Alberto
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute, Griffith University, Brisbane, Queensland, Australia
| | - Leonard Mermel
- Rhode Island Hospital and Warren Alpert Medical School of Brown University, Providence, Rhode Island, USA
| | - Claire M Rickard
- Alliance for Vascular Access Teaching and Research Group, Menzies Health Institute, Griffith University, Brisbane, Queensland, Australia
- National Centre of Research Excellence in Nursing, Griffith University, Brisbane, Queensland, Australia
| | | |
Collapse
|
7
|
Prevention of Catheter-Associated Urinary Tract Infections in Adults. Crit Care Nurse 2018; 38:84. [PMID: 29437082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
|
8
|
Al-Hameed FM, Ahmed GR, AlSaedi AA, Bhutta MJ, Al-Hameed FF, AlShamrani MM. Applying preventive measures leading to significant reduction of catheter-associated urinary tract infections in adult intensive care unit. Saudi Med J 2018; 39:97-102. [PMID: 29332116 PMCID: PMC5885128 DOI: 10.15537/smj.2018.1.20999] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2017] [Accepted: 12/09/2017] [Indexed: 11/17/2022] Open
Abstract
OBJECTIVES To determine the impact of applying the best available clinical evidence on the preventive measures to reduce the rate of catheter-associated urinary tract infections (CAUTI) in adult intensive care units (ICU). Methods: Data were collected from adult ICUs (28 beds) from 2008 to 2016. The proper use of silicon catheter, aseptic insertion technique, emptying bag three-fourth via close circuit, the use of appropriate size catheter, securing the draining tube on the thigh to keep catheter bag below patient's bladder level and removal of the catheter as early as possible were ensured in all patients. Results: Rate of UTI and urinary catheter utilization ratios were reviewed during the study period. There was a mean of 6,175 catheter days/year for ICU. Despite the overall rise in the urinary catheterization ratio over these years; we observed a significant reduction in the UTI rate per 1000 Urinary catheter days; from 2.3 in 2010 to 0.3 in 2011 and it was sustained through 2016. Conclusion: The monthly rates of CAUTI significantly declined after the enforcement of agreed strategies and interventions to prevent CAUTI rates in adult ICU.
Collapse
Affiliation(s)
- Fahad M Al-Hameed
- College of Medicine, King Saud bin Abdul-Aziz University for Health Sciences, Jeddah, Kingdom of Saudi Arabia. E-mail.
| | | | | | | | | | | |
Collapse
|
9
|
Büchtemann D, Meinhold S, Follert P. [10 years of external quality assurance in dialysis in Germany: Results and future prospects]. Z Evid Fortbild Qual Gesundhwes 2017; 126:23-30. [PMID: 29029967 DOI: 10.1016/j.zefq.2017.07.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Revised: 06/28/2017] [Accepted: 07/14/2017] [Indexed: 06/07/2023]
Abstract
BACKGROUND In 2006, the Federal Joint Committee introduced a quality assurance programme for ambulatory dialysis treatment in Germany. Regarding the impact of chronic dialysis treatment on the quality of life of patients and on health care costs, quality assurance in dialysis is considered highly relevant. The directive on Quality Assurance in Dialysis (QSD-RL) established an external quality assurance programme on the basis of the assessment of certain quality parameters combined with an internal quality management system based on benchmarking parameters in all dialysis practices and centres. Data on quality parameters are collected and analysed quarterly. Regional associations of statutory health insurance physicians take responsibility for quality improvement measures and sanctions. This article aims to provide an overview of the development of quality parameters from 2008 to 2015. METHODS We analysed the summarised annual quality reports published on the website of the Federal Joint Committee between 2009 and 2016. We present results on the so-called core quality parameters duration and frequency of dialysis sessions (both for haemodialysis patients), wKt/V for peritoneal dialysis patients, and percentage of haemodialysis patients with central venous catheters which has only been measured since 2014. RESULTS AND CONCLUSIONS In 2015, 92,000 patients received outpatient dialysis. Between 2008 and 2015, the results for the core quality parameters duration and frequency of haemodialysis improved while the results for wKt/V seemingly show an unfavourable trend. The percentage of patients with central venous catheters appears to be quite high, and thus indicates that there is potential for quality improvement. FUTURE PERSPECTIVES For the future, the Federal Joint Committee has resolved to merge the quality assurance programmes in dialysis and in kidney transplantation into a newly designed programme that has the potential to follow patients through all stages and kinds of renal replacement therapy and to focus on further aspects of treatment quality.
Collapse
Affiliation(s)
- Dorothea Büchtemann
- Spitzenverband der Gesetzlichen Krankenkassen (GKV-Spitzenverband), Abteilung Medizin, Berlin, Deutschland.
| | - Stefan Meinhold
- MDK Baden-Württemberg, KCQ - Kompetenzzentrum Qualitätssicherung / Qualitätsmanagement, Stuttgart, Deutschland
| | - Peter Follert
- Spitzenverband der Gesetzlichen Krankenkassen (GKV-Spitzenverband), Abteilung Medizin, Berlin, Deutschland
| |
Collapse
|
10
|
Bremer J, Domurath B, Böthig R, Kaufmann A, Geng V. [Medical quality standards for selected urological aids and devices : Consensus for patients with neurogenic urinary bladder dysfunction]. Urologe A 2017; 57:155-163. [PMID: 28707096 DOI: 10.1007/s00120-017-0457-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Using the CE mark of therapeutic appliances is, on its own, not sufficient enough for their appropriate and effective application. In order to treat the patient successfully, not jeopardizing the success of the treatment, medical quality criteria for therapeutic appliances care are necessary to acceptably compensate for a patient's disabilities. OBJECTIVES Medical quality criteria are formulated for the most frequently used urological aids and devices, considering hygienic requirements, international literature and the practical experience of physicians and nurses with regard to the care of patients with neurogenic urinary bladder dysfunction. METHODS An expert group of urologists, surgeons, rehabilitation physicians and nurses has developed medical quality criteria via a structured consensus procedure. Developing these criteria, the group has taken into account current jurisprudence, the current resource directory of neurourological relevant aids, data from international literature and hygiene requirements. RESULTS Medical quality requirements are discussed and defined for selected groups of urological devices (single use catheters, indwelling catheters, external catheters, urine bags, templates and diapers as well as devices for the electrostimulation of nerves). CONCLUSION The presented quality requirements offer the possibility to stabilize quality of care with neurourological relevant therapeutic appliances. The catalogue of therapeutic appliances must be urgently updated. Urinal catheters for single use must be classified as an individual product group. Devices for anterior root stimulation and neuromodulation must be included in the resource directory. The incontinence severity classification needs to be reviewed.
Collapse
Affiliation(s)
- J Bremer
- BDH-Klinik Greifswald, Karl-Liebknecht-Ring 26a, 17491, Greifswald, Deutschland
| | - B Domurath
- Kliniken Beelitz GmbH, Paracelsus-Ring 6A, 14547, Beelitz, Deutschland.
| | - R Böthig
- BG Klinikum Hamburg, Bergedorfer Str. 10, 21033, Hamburg, Deutschland
| | - A Kaufmann
- Krankenhaus St. Franziskus, Viersener Str. 450, 41063, Mönchengladbach, Deutschland
| | - V Geng
- Manfred Sauer Stiftung, Neurott 20, 74931, Lobbach, Deutschland
| |
Collapse
|
11
|
Oshima A, Kimura T, Akabane A, Kawai K. Optimal implantation of Ommaya reservoirs for cystic metastatic brain tumors preceding Gamma Knife radiosurgery. J Clin Neurosci 2017; 39:199-202. [PMID: 28117259 DOI: 10.1016/j.jocn.2016.12.042] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Accepted: 12/27/2016] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Although Ommaya reservoir implantation is effective in reducing the target volume of cystic brain metastases preceding stereotactic radiosurgery, adequate volume reduction cannot be achieved in some cases, and the factors leading to failure in volume reduction have not been clearly identified. In this study, we investigated the factors leading to failure in volume reduction after use of the Ommaya reservoir. MATERIALS AND METHODS Between December 2007 and February 2015, 38 consecutive patients with 40 cystic metastases underwent Ommaya reservoir implantation at our institution. The patient characteristics, treatment parameters, and all available clinical and neuroimaging follow-ups were analyzed retrospectively. RESULTS The rate of volume reduction was significantly related to the location of the tube tip inside the cyst. By placing the tip at or near the center, 58.7% reduction was achieved, whereas reduction of 42.6% and 7.7% occurred with deep and shallow tip placement, respectively (p=0.011). Although there was no additional surgery in the center placement group, additional surgeries were performed in 5 out of the 23 deep and shallow cases due to inadequate volume reduction. No other factors were correlated with successful volume reduction. CONCLUSION For adequate volume reduction using the Ommaya reservoir in the treatment of cystic brain metastases prior to stereotactic radiosurgery, the tip of the reservoir tube should be placed at the center of the cyst.
Collapse
Affiliation(s)
- Akito Oshima
- Department of Neurosurgery, NTT Medical Center Tokyo, Tokyo, Japan.
| | - Toshikazu Kimura
- Department of Neurosurgery, NTT Medical Center Tokyo, Tokyo, Japan
| | - Atsuya Akabane
- Gamma Knife Center, NTT Medical Center Tokyo, Tokyo, Japan
| | - Kensuke Kawai
- Department of Neurosurgery, Jichi Medical University, Tochigi, Japan
| |
Collapse
|
12
|
Affiliation(s)
- Jayle Caprara
- Jayle Caprara, RN, CRNI, VA-BC, is a Registered Nurse, Intensive Care, Henry Ford Macomb Hospital, Clinton Township, Michigan
| |
Collapse
|
13
|
Affiliation(s)
- Ann Yates
- Director of Continence Services, Cardiff and Vale University Health Board
| |
Collapse
|
14
|
Stupak DM, Trubilla JA, Groller SR. Hemodialysis Catheter Care: Identifying Best Cleansing Agents. Nephrol Nurs J 2016; 43:153-155. [PMID: 27254970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
In an attempt to create a standardized resource for cleansing both non-tunneled and tunneled hemodialysis catheters, it was discovered that all disinfectants are not compatible with all catheters. This article describes the process used to identify best practices for hemodialysis catheter care and steps taken to standardize practice throughout a hospital network. Standardized evidence-based practice preserves the integrity of catheters while allowing nurses to provide quality care to patients.
Collapse
|
15
|
Affiliation(s)
- Mary McGoldrick
- Mary McGoldrick, MS, RN, CRNI, is a Home Care and Hospice Consultant, Home Health Systems, Inc., Saint Simons Island, Georgia
| |
Collapse
|
16
|
Grapsa E, Pantelias K, Vourliotou A, Tseke P, Pipili C, Deda E, Chiousi E, Tzanatos H. Factors influencing first vascular access placement in patients starting hemodialysis. MINERVA UROL NEFROL 2016; 68:39-44. [PMID: 26856609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
BACKGROUND The aim of the study was to assess whether age, gender and the primary renal disease are associated with differences in the type of first vascular access placement. METHODS We reviewed the records of 145 patients on hemodialysis (HD) 44 females and 101 males with a mean age of 64±14.5 years, on HD for 46.9±41.2 months (range 1-252). RESULTS The primary renal diseases were diabetes (23.4%), hypertension (17.2%), glomerulonephritis (25.7%), cardiac failure (6.9%) and others (26.8%). Double lumen catheter and arteriovenous fistula was the first vascular access in 109 (75%) and 35 patients (24%) patients, respectively. Graft was the first vascular access in 1 patient (0.5%). Arteriovenous fistula was the first choice for 29.7% of the male patients and 9% of the female. Double lumen catheter was the first choice for 70.3% of the male (subclavian 50.5%, femoral 4.95%, and jugular 14.85%) and 86.4% of the female (subclavian 75%, femoral 2.3%, and jugular 9.1%) (P=0.04). Double lumen catheter was the first choice for 79.7% of the patients older than 65 years and 70.4% for the patients younger than 65 years (P=0.19). Double lumen catheter was the first choice for all the patients with cardiac failure as the primary cause of renal disease. CONCLUSION Double lumen catheter was the first vascular access for the majority of our patients, probably due to late Nephrologist's referral. Cardiac failure being the primary cause of renal disease and female gender influence also this choice, but not the age of the patients.
Collapse
Affiliation(s)
- Eirini Grapsa
- Nephrology Department, Aretaieion University Hospital, Athens, Greece -
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Kidd EA, Stewart F, Kassis NC, Hom E, Omar MI. Urethral (indwelling or intermittent) or suprapubic routes for short-term catheterisation in hospitalised adults. Cochrane Database Syst Rev 2015; 2015:CD004203. [PMID: 26661940 PMCID: PMC8612698 DOI: 10.1002/14651858.cd004203.pub3] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Indwelling urethral catheters are often used for bladder drainage in hospital. Urinary tract infection is the most common hospital-acquired infection, and a common complication of urinary catheterisation. Pain, ease of use and quality of life are important to consider, as well as formal economic analysis. Suprapubic catheterisation can also result in bowel perforation and death. OBJECTIVES To determine the advantages and disadvantages of alternative routes of short-term bladder catheterisation in adults in terms of infection, adverse events, replacement, duration of use, participant satisfaction and cost effectiveness. For the purpose of this review, we define 'short-term' as intended duration of catheterisation for 14 days or less. SEARCH METHODS We searched the Cochrane Incontinence Group Specialised Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE in process, ClinicalTrials.gov, WHO ICTRP and handsearching of journals and conference proceedings (searched 26 February 2015), CINAHL (searched 27 January 2015) and the reference lists of relevant articles. SELECTION CRITERIA We included all randomised and quasi-randomised trials comparing different routes of catheterisation for short-term use in hospitalised adults. DATA COLLECTION AND ANALYSIS At least two review authors extracted data and performed 'Risk of bias' assessment of the included trials. We sought clarification from the trialists if further information was required. MAIN RESULTS In this systematic review, we included 42 trials.Twenty-five trials compared indwelling urethral and suprapubic catheterisation. There was insufficient evidence for symptomatic urinary tract infection (risk ratio (RR) 1.01, 95% confidence interval (CI) 0.61 to 1.69; 5 trials, 575 participants; very low-quality evidence). Participants with indwelling catheters had more cases of asymptomatic bacteriuria (RR 2.25, 95% CI 1.63 to 3.10; 19 trials, 1894 participants; very low quality evidence) and more participants reported pain (RR 5.62, 95% CI 3.31 to 9.55; 4 trials, 535 participants; low-quality evidence). Duration of catheterisation was shorter in the indwelling urethral catheter group (MD -1.73, 95% CI -2.42 to -1.05; 2 trials, 274 participants).Fourteen trials compared indwelling urethral catheterisation with intermittent catheterisation. Two trials had data for symptomatic UTI which were suitable for meta-analysis. Due to evidence of significant clinical and statistical heterogeneity, we did not pool the results, which were inconclusive and the quality of evidence was very low. The main source of heterogeneity was the reason for hospitalisation as Hakvoort and colleagues recruited participants undergoing urogenital surgery; whereas in the trial conducted by Tang and colleagues elderly women in geriatric rehabilitation ward were recruited. The evidence was also inconclusive for asymptomatic bacteriuria (RR 1.04; 95% CI 0.85 to 1.28; 13 trials, 1333 participants; very low quality evidence). Almost three times as many people developed acute urinary retention with the intermittent catheter (16% with urethral versus 45% with intermittent); RR 0.45, 95% CI 0.22 to 0.91; 4 trials, 384 participants.Three trials compared intermittent catheterisation with suprapubic catheterisation, with only female participants. The evidence was inconclusive for symptomatic urinary tract infection, asymptomatic bacteriuria, pain or cost.None of the trials reported the following critical outcomes: quality of life; ease of use, and cost utility analysis. AUTHORS' CONCLUSIONS Suprapubic catheters reduced the number of participants with asymptomatic bacteriuria, recatheterisation and pain compared with indwelling urethral. The evidence for symptomatic urinary tract infection was inconclusive.For indwelling versus intermittent urethral catheterisation, the evidence was inconclusive for symptomatic urinary tract infection and asymptomatic bacteriuria. No trials reported pain.The evidence was inconclusive for suprapubic versus intermittent urethral catheterisation. Trials should use a standardised definition for symptomatic urinary tract infection. Further adequately-powered trials comparing all catheters are required, particularly suprapubic and intermittent urethral catheterisation.
Collapse
Affiliation(s)
- Emily A Kidd
- University of AberdeenCochrane Incontinence GroupHealth Sciences Building (second floor)AberdeenUKAB25 2ZD
| | - Fiona Stewart
- University of AberdeenAcademic Urology UnitForesterhillAberdeenScotlandUKAB25 2ZD
| | - Nadine C Kassis
- Toledo Clinic Urogynecology3425 Executive ParkwaySuite 108ToledoUSAOH 43606
| | - Emily Hom
- Baylor Scott and White Health2401 South 31st StreetMS‐01‐E316ATempleTXUSA76508
| | - Muhammad Imran Omar
- University of AberdeenAcademic Urology UnitForesterhillAberdeenScotlandUKAB25 2ZD
| | | |
Collapse
|
18
|
Browning S, Omal H, Barry P, Ramaswamykanive H. Package inserts: to believe or not to believe. Anaesth Intensive Care 2015; 43:280. [PMID: 25735703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
|
19
|
Gowda A, Pavan M, Babu K. Vascular access profile in maintenance hemodialysis patients. Iran J Kidney Dis 2014; 8:218-224. [PMID: 24878945] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Received: 09/12/2013] [Accepted: 09/15/2013] [Indexed: 06/03/2023]
Abstract
INTRODUCTION The aims of this study was to evaluate maintenance hemodialysis population in a tertiary care hospital based dialysis unit for vascular access (VA) types, to compare native arteriovenous fistula (AVF) and arteriovenous graft (AVG) survival, and to assess risk factors for access failure. MATERIALS AND METHODS A total of 182 patients on maintenance hemodialysis were evaluated and followed up in terms of VA type and VA outcomes. RESULTS Among 103 prevalent patients, 15.5% initiated dialysis with AVF. At the time of the study, 67.9% of the prevalent patients had an AVF and 29.1% had AVG. Of 79 incident patients, 64% were followed up for more than 3 months by nephrologists before initiation of dialysis. Among these patients, 13.6% were initiated with AVF. There were 25 primary failures and 50 secondary failure episodes. Of the 50 secondary failures, 15 were AVF failures and 31 AVG failures. Vascular access survival was significantly superior with AVF as compared with AVG (P = .03). With longer dialysis periods, failure rates were higher. Follow-up with nephrologists prior to initiation of dialysis had a major influence on VA. CONCLUSIONS Arteriovenous fistula is the best VA for maintenance hemodialysis. However, when the vasculature is not ideal for AVF, AVG should be constructed. A small percentage of our patients had fistula at initiation of dialysis. This is mainly due to late nephrology referrals and also due to reluctance of patients to undergo surgical access placement when they are relatively asymptomatic.
Collapse
Affiliation(s)
| | - Malleshappa Pavan
- Division of Nephrology, Department of Medicine, Adichunchanagiri Institute of Medical Sciences, BG Nagara, Karnataka state, India.
| | | |
Collapse
|
20
|
Tuffaha HW, Rickard CM, Webster J, Marsh N, Gordon L, Wallis M, Scuffham PA. Cost-effectiveness analysis of clinically indicated versus routine replacement of peripheral intravenous catheters. Appl Health Econ Health Policy 2014; 12:51-58. [PMID: 24408785 DOI: 10.1007/s40258-013-0077-2] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
BACKGROUND Millions of peripheral intravenous catheters are used worldwide. The current guidelines recommend routine catheter replacement every 72-96 h. This practice requires increasing healthcare resource use. The clinically indicated catheter replacement strategy is proposed as an alternative. OBJECTIVES To assess the cost effectiveness of clinically indicated versus routine replacement of peripheral intravenous catheters. METHODS A cost-effectiveness analysis from the perspective of Queensland Health, Australia, was conducted alongside a randomized controlled trial. Adult patients with an intravenous catheter of expected use for longer than 4 days were randomly assigned to receive either clinically indicated replacement or third-day routine replacement. The primary outcome was phlebitis during catheterization or within 48 h after catheter removal. Resource use data were prospectively collected and valued (2010 prices). The incremental net monetary benefit was calculated with uncertainty characterized using bootstrap simulations. Additionally, value of information (VOI) and value of implementation analyses were performed. RESULTS The clinically indicated replacement strategy was associated with a cost saving per patient of AU$7.60 (95% confidence interval [CI] 4.96-10.62) and a non-significant difference in the phlebitis rate of 0.41% (95% CI -1.33 to 2.15). The incremental net monetary benefit was AU$7.60 (95% CI 4.96-10.62). The expected VOI was zero, whereas the expected value of perfect implementation of the clinically indicated replacement strategy was approximately AU$5 million over 5 years. CONCLUSION The clinically indicated catheter replacement strategy is cost saving compared with routine replacement. It is recommended that healthcare organizations consider changing to a policy whereby catheters are changed only if clinically indicated.
Collapse
Affiliation(s)
- Haitham W Tuffaha
- Griffith Health Institute, Griffith University, Gold Coast, QLD, Australia,
| | | | | | | | | | | | | |
Collapse
|
21
|
Fernández-Ruiz M, Carretero A, Díaz D, Fuentes C, González JI, García-Reyne A, Aguado JM, López-Medrano F. Hospital-wide survey of the adequacy in the number of vascular catheters and catheter lumens. J Hosp Med 2014; 9:35-41. [PMID: 24323802 DOI: 10.1002/jhm.2130] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2013] [Revised: 10/26/2013] [Accepted: 11/11/2013] [Indexed: 11/08/2022]
Abstract
BACKGROUND Removal of unnecessary catheters has been proposed as an important measure to reduce catheter-related morbidity. Nevertheless, there is scarce information about the potential magnitude of such intervention. OBJECTIVE The present study was aimed at analyzing the appropriateness of use of vascular catheters and catheter lumens in the inpatient setting. DESIGN Cross-sectional survey. SETTING The entire population of adult inpatients admitted to a 1368-bed tertiary-care hospital in a single day. MEASUREMENTS We used a set of preestablished criteria to evaluate the appropriateness of use of vascular catheters and catheter lumens according to the number and administration regimen of intravenous drugs. RESULTS Out of 834 patients, 575 (68.9%) had ≥1 vascular catheters in place on the day of the survey. The type and distribution of the 703 surveyed catheters were peripheral venous catheter, 80.6%; central venous catheter, 15.8%; and arterial catheter, 3.6%. We found an overall mean of 2.06 ± 0.82 lumens per catheter, with significant differences between intensive care units and conventional wards (P < 0.0001). Based on our criteria, 126 out of 575 patients (21.9%) had an inappropriate number of catheters (medical wards, 20.0%; surgical wards, 23.9%; intensive care units, 26.3%), and 631 out of 14248 nonarterial catheter lumens (43.6%) were considered unnecessary. CONCLUSIONS Significant room exists for improving the adequacy of the number of vascular catheters and catheter lumens as a potentially useful tool for decreasing the incidence of catheter-related bloodstream infection.
Collapse
Affiliation(s)
- Mario Fernández-Ruiz
- Unit of Infectious Diseases, Institute for Research Hospital "12 de Octubre" (i+12), University Hospital "12 de Octubre", Madrid, Spain; School of Medicine, Universidad Complutense, Madrid, Spain
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Chopra V, Kuhn L, Coffey CE, Salameh M, Barron J, Krein S, Flanders SA, Saint S. Hospitalist experiences, practice, opinions, and knowledge regarding peripherally inserted central catheters: a Michigan survey. J Hosp Med 2013; 8:309-14. [PMID: 23526586 DOI: 10.1002/jhm.2031] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2012] [Revised: 02/04/2013] [Accepted: 02/07/2013] [Indexed: 11/07/2022]
Abstract
BACKGROUND Peripherally inserted central catheters (PICCs) are commonly inserted during hospitalization for a variety of clinical indications. OBJECTIVE To understand hospitalist experience, practice, knowledge, and opinions as they relate to PICCs. DESIGN AND SETTING Web-based survey of hospitalists in 5 healthcare systems (representing a total of 10 hospitals) across Michigan. RESULTS The overall response rate was 63% (227 hospitalists received invitations; 144 responded). Compared with central venous catheters, hospitalists felt that PICCs were safer to insert (81%) and preferred by patients (74%). Although 84% of respondents reported that placing a PICC solely to obtain venous access was appropriate, 47% also indicated that 10%-25% of PICCs inserted in their hospitals might represent inappropriate placement. Hospitalist knowledge regarding PICC-related venous thromboembolism was poor, with only 4% recognizing that PICC-tip verification was performed principally to prevent thrombosis. Furthermore, several potential practice-related concerns were identified: one-third of hospitalists indicated that they never examine PICCs for externally evident problems, such as exit-site infection; 48% responded that once inserted, they did not remove PICCs until a patient was ready for discharge; and 51% admitted that, at least once, they had "forgotten" that their patient had a PICC. CONCLUSIONS Hospitalist experiences, practice, opinions, and knowledge related to PICCs appear to be variable. Because PICC use is growing and is often associated with complications, examining the impact of such variation is necessary. Hospitals and health systems should consider developing and implementing mechanisms to monitor PICC use and adverse events.
Collapse
Affiliation(s)
- Vineet Chopra
- Division of General Medicine, Department of Internal Medicine, University of Michigan Health System, Ann Arbor, MI 48109, USA.
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Abstract
BACKGROUND Prolonged urinary catheterization is common amongst people in long-term care settings and this carries a high risk of developing a catheter-related urinary tract infection and associated complications. A variety of different kinds of urethral catheters are available. Some have been developed specifically to lower the risk of catheter-associated infection, for example antiseptic or antibiotic impregnated catheters. Ease of use, comfort and handling for the caregivers and patients, and cost-effectiveness are also important factors influencing choice. OBJECTIVES The primary objective was to determine which type of indwelling urinary catheter is best to use for long-term bladder drainage in adults. SEARCH METHODS We searched the Cochrane Incontinence Group Specialised Register (last searched 31 March 2011), which includes searches of CENTRAL, MEDLINE and handsearching of journals and conference proceedings, and the reference lists of relevant articles. SELECTION CRITERIA All randomised trials comparing types of indwelling urinary catheters for long-term catheterization in adults. Long-term catheterization was defined as more than 30 days. DATA COLLECTION AND ANALYSIS Data extraction has been undertaken by two review authors working independently and simultaneously. Any disagreement has been resolved by a third review author. The included trial data were handled according to the methods of the Cochrane Handbook for Systematic Reviews of Interventions. MAIN RESULTS Three trials were included, involving 102 adults in various settings. Two trials had a parallel group design and one was a randomised cross-over trial.Only two of the six targeted comparisons were assessed by these trials: antiseptic impregnated catheters versus standard catheters (one trial) and one type of standard catheter versus another standard catheter (two trials).The single small cross-over trial was inadequate to assess the value of silver alloy (antiseptic) impregnated catheters. In the two trials comparing different types of standard catheters, estimates of differences were all imprecise because the trials also had small sample sizes; confidence intervals (CI) were too wide to rule out clinically important differences. One trial did suggest, however, that the use of a hydrogel coated latex catheter rather than a silicone catheter may be better tolerated (risk ratio (RR) for need for early removal 0.41, 95% CI 0.22 to 0.77). AUTHORS' CONCLUSIONS The updated search could not reveal any additional evidence. Very few trials have compared different types of catheter for long-term bladder drainage. All trials were small and showed methodological weaknesses. Therefore, the evidence was not sufficient as a reliable basis for practical conclusions. Further, better quality trials are needed to address the current lack of evidence in this clinically important area.
Collapse
Affiliation(s)
- Patrick Jahn
- Nursing Research and Development, University Hospital Halle, Halle/ Saale, Germany.
| | | | | |
Collapse
|
24
|
|
25
|
Fink R, Gilmartin H, Richard A, Capezuti E, Boltz M, Wald H. Indwelling urinary catheter management and catheter-associated urinary tract infection prevention practices in Nurses Improving Care for Healthsystem Elders hospitals. Am J Infect Control 2012; 40:715-20. [PMID: 22297241 DOI: 10.1016/j.ajic.2011.09.017] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2011] [Revised: 09/22/2011] [Accepted: 09/22/2011] [Indexed: 11/19/2022]
Abstract
BACKGROUND Indwelling urinary catheters (IUCs) are commonly used in hospitalized patients, especially elders. Catheter-associated urinary tract infections (CAUTIs) account for 34% of all health care associated infections in the United States, associated with excess morbidity and health care costs. Adherence to CAUTI prevention practices has not been well described. METHODS This study used an electronic survey to examine IUC care practices for CAUTI prevention in 3 areas-(1) equipment and alternatives and insertion and maintenance techniques; (2) personnel, policies, training, and education; and (3) documentation, surveillance, and removal reminders-at 75 acute care hospitals in the Nurses Improving the Care of Healthsystem Elders (NICHE) system. RESULTS CAUTI prevention practices commonly followed included wearing gloves (97%), handwashing (89%), maintaining a sterile barrier (81%), and using a no-touch insertion technique (73%). Silver-coated catheters were used to varying degrees in 59% of the hospitals; 4% reported never using a catheter-securing device. Urethral meatal care was provided daily by 43% of hospitals and more frequently that that by 41% of hospitals. Nurses were the most frequently reported IUC inserters. Training in aseptic technique and CAUTI prevention at the time of initial nursing hire was provided by 64% of hospitals; however, only 47% annually validated competency in IUC insertion. Systems for IUC removal were implemented in 56% of hospitals. IUC documentation and routine CAUTI surveillance practices varied widely. CONCLUSIONS Although many CAUTI prevention practices at NICHE hospitals are in alignment with evidence-based guidelines, there is room for improvement. Further research is needed to identify the effect of enhanced compliance with CAUTI prevention practices on the prevalence of CAUTI in NICHE hospitals.
Collapse
Affiliation(s)
- Regina Fink
- Department of Professional Resources, University of Colorado Hospital, Aurora, CO 80045, USA.
| | | | | | | | | | | |
Collapse
|
26
|
White J, Carolan-Rees G. PleurX peritoneal catheter drainage system for vacuum-assisted drainage of treatment-resistant, recurrent malignant ascites: a NICE Medical Technology Guidance. Appl Health Econ Health Policy 2012; 10:299-308. [PMID: 22779402 DOI: 10.1007/bf03261864] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
The PleurX peritoneal drainage catheter for drainage of malignant ascites in a community setting has been evaluated by the NICE Medical Technologies Evaluation Programme. This article outlines the evidence included in the Sponsor's submission, the independent critique by the External Assessment Centre (EAC) and the recommendations made by the Medical Technologies Advisory Committee (MTAC). In accordance with the scope issued by NICE, the intervention technology was the indwelling PleurX peritoneal catheter drainage system, the comparator was large-volume paracentesis (LVP; inpatient or outpatient) and the population was patients with treatment-resistant, recurrent malignant ascites. Nine studies (ten papers) were identified with a total of 180 PleurX-treated patients; six were case series with more than four patients that, despite being low in the hierarchy of evidence, provided useful safety information. Technical success of the initial PleurX placement procedure was 100% across five studies which reported this outcome. One study reported equal complication rates between patients treated with indwelling PleurX catheters (40 patients and 40 catheters) and those receiving repeated LVPs (67 patients and 392 procedures), 7.5% (3/40; 95% CI 1.6, 20) and 7.5% (5/67; 95% CI 2.2, 15), respectively. All remaining studies were single-arm and reported complication rates of between 0% and 59%; this wide range was largely due to variation in the definition of complications and adverse events. Using validated tools, one case series reported improvements in several ascites-related symptoms after placement of the PleurX catheter; however, an overall quality-of-life improvement at 12 weeks was not demonstrated. Positive patient opinions relating to improved symptom control and convenience were reported in a qualitative study. Cost analysis demonstrated that PleurX offered savings to the NHS when compared with repeated LVPs performed in an inpatient setting. This saving of £679 per patient was driven primarily by reducing hospital bed days (year 2009-2010 values), but would require 23.5 additional community nurse visits. Advice from clinical experts was that additional home visits were overestimated as many patients would receive such visits regardless of whether a PleurX drain had been fitted. The model demonstrated that PleurX would be more expensive than LVP procedures performed in a setting where one or less hospital bed days were used (e.g. day case or outpatient). There was uncertainty surrounding the number of patients for whom insertion of a PleurX drain would be appropriate as well as the point in the care pathway at which such treatment should be administered. MTAC supported the case for adoption and considered that the available evidence showed PleurX was clinically effective, has low complication rates, can improve quality of life and is less costly than inpatient LVP. In Medical Technology Guidance 9 (MTG9), NICE recommended that PleurX peritoneal catheter drainage system be considered for use in patients with treatment-resistant, recurrent malignant ascites.
Collapse
Affiliation(s)
- Judith White
- Cedar, Cardiff and Vale University Health Board, Cardiff, Wales, UK.
| | | |
Collapse
|
27
|
Campbell B, Campbell M. NICE Medical Technologies Guidance: a novel and rigorous methodology to address a new health technology assessment challenge. Appl Health Econ Health Policy 2012. [PMID: 22909081 PMCID: PMC3713955 DOI: 10.1007/bf03261863] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Affiliation(s)
- Bruce Campbell
- />Medical Technologies Advisory Committee, National Institute for Health and Clinical Excellence, Manchester, UK
| | - Mark Campbell
- />Medical Technologies Evaluation Programme, National Institute for Health and Clinical Excellence, Level 1A, City Tower, Piccadilly Plaza, Manchester, M1 4BD Uk
| |
Collapse
|
28
|
Campbell B, Campbell M. NICE Medical Technologies Guidance: a novel and rigorous methodology to address a new health technology assessment challenge. Appl Health Econ Health Policy 2012; 10:295-7. [PMID: 22909081 DOI: 10.2165/11640550-000000000-00000] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Affiliation(s)
- Bruce Campbell
- Medical Technologies Advisory Committee, National Institute for Health and Clinical Excellence, Manchester, UK
| | | |
Collapse
|
29
|
Duval L. Quality improvement project: hemodialysis vascular access management trends report. J Ark Med Soc 2012; 109:36-37. [PMID: 22984708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Vascular access for the delivery of hemodialysis is the initial clinical procedure for any applicable HD patient. It behooves clinicians to ensure that these patients have a vascular access management plan assuring the best permanent vascular access possible for optimal patient care outcomes. AVFs are considered the preferred access based on their superior patency, minimal complication rates, and decreased risk of patient mortality. This project's activities continue to address practice barriers and motivate changes where necessary to improve patient care.
Collapse
|
30
|
Johansen KL. Importance of more judicious catheter use. Arch Intern Med 2012; 172:262. [PMID: 22231609 DOI: 10.1001/archinternmed.2011.621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
|
31
|
Affiliation(s)
- Michelle Mourad
- Department of Medicine, University of California, San Francisco, CA 94143, USA.
| | | |
Collapse
|
32
|
Elpers L. Dialysis access: issues and considerations. Nephrol News Issues 2011; 25:22-23. [PMID: 22204156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
|
33
|
Abstract
The evaluation and management of volume status in patients with heart failure is a challenge for most clinicians. In addition, such an evaluation is possible only during a personal clinician-patient interface. The ability to acquire hemodynamic data continuously with the help of implanted devices with remote monitoring capability can provide early warning of heart failure decompensation and thus may aid in preventing hospitalizations for heart failure. The data obtained also may improve the understanding of the disease process. It is important for the clinician treating patients who have heart failure to become acquainted with this type of technology and learn to interpret and use these data appropriately. This article reviews the implantable hemodynamics monitors currently available.
Collapse
|
34
|
Zhang S, Lu J, Zhang J. [Summary about the progress and specifications of FDA regarding intravascular catheters]. Zhongguo Yi Liao Qi Xie Za Zhi 2011; 35:269-273. [PMID: 22097751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
This article summarizes the progress and specifications of FDA regarding intravascular catheters, and hope this would be helpful to people concerned.
Collapse
Affiliation(s)
- Shiqing Zhang
- Center for Medical Device Evaluation, SFDA, Beijing 100044.
| | | | | |
Collapse
|
35
|
Chen YZ, Yan CY. [Hematology-oncology port-A: improving nursing care quality]. Hu Li Za Zhi 2011; 58:64-72. [PMID: 21678269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
BACKGROUND Hospitalized hematology-oncology patients undergoing chemotherapy face a significant risk of port-A related bloodstream infections. Nurses are uniquely positioned to help adjust clinical practices necessary to prevent port-A related bloodstream infections and improve patient outcomes. Between July 1st, 2008 and June 30th, 2009, twelve patients in our ward were stricken with port-A related bloodstream infections (an infection rate of .318%). Data analysis indicated inadequate nursing competency in all aspects of port-A care. Nurses did not have adequate knowledge of port-A modified standard care protocols and did not provide dressings suited to hematology-oncology patient needs. Also, both patients and caregivers lacked adequate skin care knowledge. Our team developed a project to address and minimize port-A related bloodstream infection issues in our hospital. OBJECTS The authors designed this project to enhance integration of both the central line insertion care and maintenance practice bundles in order to reduce port-A related bloodstream infection incidence. RESOLUTION The plan was implemented from August 15, 2009 to December 20, 2009. It included establishing a standardization port-A care protocol, implementing a more appropriate dressing type, performing an irregular audit of port-A care techniques, holding educational training, and establishing skin care instructions for patients and their families. RESULTS Hematology-oncology patient port-A related bloodstream infections fell from .318% pre-implementation to .099% post-implementation. The effective rate of improvement was 68.87%. CONCLUSION Standardization of Port-A care under this project achieved infection reduction results that achieved our anticipated goals. This project furthermore enhanced the delivery and quality of patient nursing services. This experience can serve as a reference to medical organizations involved in hematology-oncology patient care.
Collapse
|
36
|
Timofeev I, Czosnyka M, Carpenter KLH, Nortje J, Kirkpatrick PJ, Al-Rawi PG, Menon DK, Pickard JD, Gupta AK, Hutchinson PJ. Interaction between brain chemistry and physiology after traumatic brain injury: impact of autoregulation and microdialysis catheter location. J Neurotrauma 2011; 28:849-60. [PMID: 21488707 PMCID: PMC3113421 DOI: 10.1089/neu.2010.1656] [Citation(s) in RCA: 67] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Bedside monitoring of cerebral metabolism in traumatic brain injury (TBI) with microdialysis is gaining wider clinical acceptance. The objective of this study was to examine the relationship between the fundamental physiological neuromonitoring modalities intracranial pressure (ICP), cerebral perfusion pressure (CPP), brain tissue oxygen (P(bt)O(2)), and cerebrovascular pressure reactivity index (PRx), and cerebral chemistry assessed with microdialysis, with particular focus on the lactate/pyruvate (LP) ratio as a marker of energy metabolism. Prospectively collected observational neuromonitoring data from 97 patients with TBI, requiring neurointensive care management and invasive cerebral monitoring, were analyzed. A linear mixed model analysis was used to account for individual patient differences. Perilesional tissue chemistry exhibited a significant independent relationship with ICP, P(bt)O(2) and CPP thresholds, with increasing LP ratio in response to decrease in P(bt)O(2) and CPP, and increase in ICP. The relationship between CPP and chemistry depended upon the state of PRx. Within the studied physiological range, tissue chemistry only changed in response to increasing ICP or drop in P(bt)O(2)<1.33 kPa (10 mmHg). In agreement with previous studies, significantly higher levels of cerebral lactate (p<0.001), glycerol (p=0.013), LP ratio (p<0.001) and lactate/glucose (LG) ratio (p=0.003) were found in perilesional tissue, compared to "normal" brain tissue (Mann-Whitney test). These differences remained significant following adjustment for the influences of other important physiological parameters (ICP, CPP, P(bt)O(2), P(bt)CO(2), PRx, and brain temperature; mixed linear model), suggesting that they may reflect inherent tissue properties related to the initial injury. Despite inherent biochemical differences between less-injured brain and "perilesional" cerebral tissue, both tissue types exhibited relationships between established physiological variables and biochemistry. Decreases in perfusion and oxygenation were associated with deteriorating neurochemistry and these effects were more pronounced in perilesional tissue and when cerebrovascular reactivity was impaired.
Collapse
Affiliation(s)
- Ivan Timofeev
- Division of Neurosurgery, University of Cambridge, Addenbrooke's Hospital, Cambridge, United Kingdom.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Blagg CR. More hemodialysis is not bad for blood access. Nephrol News Issues 2011; 25:28-29. [PMID: 21608456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
|
38
|
Fusselman M. Results of a customer-based, post-market surveillance survey of the HeRO access device. Nephrol News Issues 2010; 24:30-33. [PMID: 20865958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
In order to supplement post-market surveillance data on the HeRO vascular access device, a non-scientific customer survey was conducted to obtain quantitative data from dialysis providers caring for patients implanted with the device. Dialysis nurses involved in the care of HeRO patients were contacted in order to obtain post-implant device performance information for 10% of patients implanted with the device at the time of the survey. Thirty-eight dialysis units with a total of 65 HeRO patients participated in the survey. The total duration of HeRO device use was 348.4 months with an average use of 5.4 months. Thirty-eight of the 65 HeRO patients (58.5%) were reported to not have experienced any performance issues. There were 28 device performance incidents reported for the remaining 27 patients included in the survey. Occlusion was the single most commonly reported device-related performance issue with 18 patients (27.7%) experiencing 25 occlusive episodes. The majority of the patients who had an occlusion (66.7%) only experienced one occlusive event. Infections occurred in 4 patients (6.2%) with an overall infection rate of 0.38 per 1,000 patient days. Post-market clinical experience during the first 18 months of commercialization of the HeRO device were in line with expectations based on the results from initial clinical studies with the device. Device occlusion remains the most commonly reported performance issue with the reported rate in this survey less than that which was reported in earlier published studies with the device.
Collapse
|
39
|
Wilkes D, Cook M, Solanki D. Intrathecal catheter-syringe adaptor for short-term intrathecal analgesia with an externalized pump: a case report. Pain Physician 2010; 13:151-156. [PMID: 20309381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
BACKGROUND In most patients, cancer pain is effectively treated with conservative medical management consisting of oral and/or transdermal analgesics. Cancer patients tend to fail conservative medical management near the end of their life expectancy, thus requiring alternative routes of analgesia such as intravenous, epidural, or intrathecal. The intrathecal route provides the most effective analgesia due to the close proximity of the opioid receptors in the spinal cord. Though there are many techniques that exist for intrathecal drug delivery, complications can limit effectiveness such as infection, bleeding, cerebrospinal fluid (CSF) leaks, post-dural puncture headaches (PDPH), pump and/or catheter malfunctions, or limitations of technical expertise. Therefore, an important goal in palliative cancer pain therapy is to use equipment that is going to have the fewest number of complications and will be the most familiar to the health care providers. We describe the combination of the Medtronic Indura 1P catheter, which has the least catheter-related complications and can be used with any external drug infusion pump. These are regular infusion pumps that the health care workers are familiar with so they can provide excellent and efficient service to the patient. METHODS In an operating room, the intrathecal catheter was placed using sterile technique under fluoroscopic guidance. The epidural space was identified with loss of resistance technique. Then the introducer needle (supplied in the Indura 1P catheter kit) was advanced until free-flowing CSF was obtained. The spinal catheter was advanced into the intrathecal space through the introducer needle to lumbar 2-3 level. The catheter was tunneled subcutaneously 10 cm lateral to the catheter exit site. A syringe filling device was inserted into the catheter opening and was secured with silk suture. A luer lock syringe was attached to the syringe filling device and CSF was aspirated. The syringe filling device was capped and later attached to an external drug infusion pump. RESULTS We report the successful use of the Medtronic Indura 1P, one piece intrathecal catheter, connected to the external drug pump for a 3 week period in a patient with metastatic cervical cancer for palliative pain control. LIMITATIONS Case report only. CONCLUSION This technique is simple to perform by pain specialists. The catheter modification allows the use of the Medtronic intrathecal catheter with standard external drug infusion pumps. This facilitates the patient's care in the hospice setting.
Collapse
Affiliation(s)
- Denise Wilkes
- University of Texas Medical Branch, Galveston, Texas 77555, USA.
| | | | | |
Collapse
|
40
|
Bak J, Ladefoged SD, Tvede M, Begovic T, Gregersen A. Disinfection of Pseudomonas aeruginosa biofilm contaminated tube lumens with ultraviolet C light emitting diodes. Biofouling 2010; 26:31-38. [PMID: 20390554 DOI: 10.1080/08927010903191353] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Bacterial biofilms on long-term catheters are a major source of infection. Exposure to ultraviolet C (UVC - 265 nm) light was shown in an earlier study to reduce the number of bacteria substantially on ex vivo treated urinary patient catheters. Very large doses (long treatment times) should, however, be applied to obtain 99.9% disinfection rates. The major reason was that besides cells the mature biofilm contained absorbing and scattering particulates, which made the biofilm opaque. The potential of UVC light emitting diodes (LED) for disinfection purposes in catheter-like tubes contaminated with biofilm was investigated. It was shown that UVC light propagation was possible through both Teflon and catheter tubes (silicone). The disinfection efficiency of the diodes was demonstrated on tubes contaminated artificially with a Pseudomonas aeruginosa biofilm. The tubes were connected to a flow system and biofilms were produced during a 3 day period. Tubes in lengths of 10 (Teflon, silicone) and 20 cm (Teflon) were contaminated. Tubes for control and for UVC treatment were contaminated in parallel. Biofilms were sampled from the total inner surface of the tubes. Colony counts on the control samples were in the range of 5 x 10(5)-1.3 x 10(9) CFU ml(-1), with disinfection rates in the range 96-100%. The applied UVC doses corresponded to treatment times between 15 and 300 min. Disinfection (100%) was obtained in 10 cm Teflon tubes exposed for 30 min (detection limit <5 CFU ml(-1)). The same result was obtained for a 20 cm Teflon tube exposed for 300 min. The disinfection rate was 96% for the 20 cm tube if the dose was reduced to 30 min. A disinfection rate of 99.99% was observed for a 10 cm peritoneal dialysis catheter tube (silicone) exposed for 300 min. Differences between the tubes were dependent on the differences in length and the type of the material. The UVC light was transmitted six times more efficiently in Teflon than in silicone tubes of equal length (10 cm). The germicidal effect to obtain a 99.99% killing rate for the biofilm ( approximately 78 J m(-2)) is comparable to that for the planktonic bacterium. It is concluded that there is potential for LED UVC light sources if they are used for disinfection of thin biofilms.
Collapse
Affiliation(s)
- Jimmy Bak
- DTU Fotonik Technical University of Denmark, Roskilde, Denmark.
| | | | | | | | | |
Collapse
|
41
|
Dupont C, Kriegel I. [Place for implantable catheters, results of an audit of knowledge of private homecare nurses]. Soins 2010:23-27. [PMID: 20201465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Affiliation(s)
- Christian Dupont
- Centre de ressources et de compétences de la mucoviscidose (CRCM) adulte, Hôpital Cochin (AP-HP), Paris.
| | | |
Collapse
|
42
|
Dal Molin A, Gatta C, Festini F. Management of totally implantable vascular access devices in patients with cystic fibrosis. Minerva Pediatr 2009; 61:549-555. [PMID: 19794380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Cystic fibrosis (CF) is a genetic disease associated with recurrent lung infections, that represent a major cause of mortality and morbidity. Cystic fibrosis requires frequent antibiotic treatments, sometimes by mouth or via aerosol but often via the intravenous route. Totally implanted venous access devices (ports) allow an easy and safe vascular access for unlimited periods of time, and they can be used in CF to administer antibiotics and other i.v. infusions; if compared to external central venous catheters, ports are better tolerated, since they permit almost unlimited physical activity and do not interfere with patient's self-image. Though ports require a minimal level of care, they may be sometimes associated with relevant complications, which can be insertion-related (pneumothorax, arterial puncture, local hematoma), or management-related (infection, occlusion of the lumen, venous thrombosis). This article summarizes some recommendations on the management of ports in CF, considering the existing literature. Still, some issues remain unsolved and will need further research and studies.
Collapse
|
43
|
Anselmo-Murphy AM. Challenges of IP chemotherapy for ovarian cancer. Oncology (Williston Park) 2009; 23:21-22. [PMID: 19856604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
|
44
|
Powers MLE, Lublin D, Eby C, Leitman SF, Dynis M, Despotis GJ. Safety concerns related to use of unapproved needles for accessing implantable venous access devices. Transfusion 2009; 49:2008-9. [PMID: 19735506 DOI: 10.1111/j.1537-2995.2009.02296.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
45
|
|
46
|
|
47
|
Nguyen VD, Griffith CN, Reus J, Barclay C, Alford S, Treat L, Hanthorn M, Ball L, Lawson L, Ledeen M, Buss J. Successful AV fistula creation does not lead to higher catheter use: the experience by the Northwest Renal Network 16 Vascular Access Quality Improvement Program. Four years follow-up. J Vasc Access 2008; 9:260-268. [PMID: 19085896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023] Open
Abstract
BACKGROUND In 2002, the Center for Medicare and Medicaid Services (CMS) required all 18 Renal Networks to participate in a Vascular Access Quality Improvement Program (QIP). The Northwest Renal Network (NWRN 16) chose to increase arteriovenous fistula (AVF) use. NWRN 16 hypothesized that strategies which targeted the improvement of AVF rate and the reduction of catheter use were the same. In December 2001, 44.2% of hemodialysis (HD) patients in the NWRN 16 received HD using an AVF which met the Dialysis Outcome Quality Initiative (K/DOQI) 40% AVF guideline for prevalent patients. However, 43% of HD facilities (2869 patients) had less than 40% of AVF and higher HD catheter rates than the average Network catheter rates (25.0 vs. 20.3%). To address the needs of underperforming facilities, NWRN 16 provided education and tools for their vascular access decision makers to promote AVF creation and catheter reduction. METHODS In 2002, NWRN 16 sponsored four regional workshops targeted at nephrologists, vascular surgeons, HD nurses, and interventional radiologists. RESULTS Percentage of AVFs in use in invited facilities increased from 31.3% pre-intervention to 56.2% at 4 yrs: 78% increase (99% confidence interval: 77.8% to 81.5%). Percentage of catheters increased from 25% to 25.8%: 3.2% change over 4 yrs (99% confidence interval: 2.5% to 4%). CONCLUSION The success of Network 16's AVF interventions demonstrates the effectiveness of Network education promoting multidisciplinary teamwork, and innovative strategies to increase dramatically AVF use without substantial increase in catheter use.
Collapse
Affiliation(s)
- V D Nguyen
- Memorial Nephrology Associates, Olympia, WA 98506, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
48
|
Minkler MA. What are those tubes for? What you need to know about central venous access devices. EMS Mag 2008; 37:46, 48, 50 passim. [PMID: 18814671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Prehospital providers who are trained to access and utilize existing CVADs, including Groshong, Hickman, Broviac, PICC lines and implanted ports, will be able to establish rapid i.v.s. The CVADs, which should be used in critical scenarios like shock, cardiac arrest and critical medical conditions, will allow EMS to administer medications and fluids to patients in whom i.v. access may otherwise be impossible. Providers should review with their medical directors the feasibility and practical application of using these devices, ensuring they have the correct training and equipment to use these potentially lifesaving devices.
Collapse
|
49
|
Hannam S, Hasib A, McCarthy L. Confusion over markings on a percutaneous long line. Eur J Pediatr 2008; 167:455. [PMID: 17429691 DOI: 10.1007/s00431-007-0479-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2007] [Accepted: 03/19/2007] [Indexed: 10/23/2022]
Affiliation(s)
- S Hannam
- Department of Child Health, Kings College Hospital, Denmark Hill, London, SE5 9RS, UK.
| | | | | |
Collapse
|
50
|
Lee CK, Tay LL, Ng WH, Ng I, Ang BT. Optimization of ventricular catheter placement via posterior approaches: a virtual reality simulation study. ACTA ACUST UNITED AC 2008; 70:274-7; discussion 277-8. [PMID: 18262623 DOI: 10.1016/j.surneu.2007.07.020] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2007] [Accepted: 07/03/2007] [Indexed: 11/19/2022]
Abstract
BACKGROUND This study aimed to evaluate 2 commonly used posterior approach entry points for ventricular cannulation and the ideal trajectories using 3-dimensional virtual reality technology. METHODS Magnetic resonance imaging data of 10 patients without gross ventricular dilatation or distortion were retrieved and reconstructed. A stereoscopic 3-dimensional preoperative planning system was used to designate the entry points. Various trajectories were simulated. The ideal trajectory was determined as the one that provided direct entry into the atrium or body of the lateral ventricle en route to the ipsilateral frontal horn. RESULTS Magnetic resonance imaging data sets from 10 patients were used. For the entry point 6 cm above and 4 cm lateral to the inion (Frazier's point), ideal cannulation was achieved for all 10 patients when the selected target was 4 cm above the contralateral medial canthus. When the contralateral medial canthus was targeted, 5 patients had successful outcomes. There were only 3 satisfactory outcomes each when the ipsilateral medial canthus and glabella were targeted. The target 2 cm above the glabella yielded 2 satisfactory outcomes. The entry point 3 cm above and 2 cm lateral to the inion (Dandy's point) had 10 satisfactory outcomes when the target point was 2 cm above the glabella. All the other target points, namely, ipsilateral medial canthus, contralateral medial canthus, 4 cm above the contralateral medial canthus and glabella yielded poor results. CONCLUSIONS For satisfactory placement when entering via Frazier's point, the best trajectory target would be 4 cm above the contralateral medial canthus. When entering via Dandy's point, the best target would be 2 cm above the glabella.
Collapse
Affiliation(s)
- Cheng Kiang Lee
- Department of Neurosurgery, National Neuroscience Institute, 308433, Singapore.
| | | | | | | | | |
Collapse
|