1
|
Teo ZL, Ang M. Femtosecond laser-assisted in situ keratomileusis versus small-incision lenticule extraction: current approach based on evidence. Curr Opin Ophthalmol 2024; 35:278-283. [PMID: 38700941 DOI: 10.1097/icu.0000000000001060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2024]
Abstract
PURPOSE OF REVIEW Laser keratorefractive surgery achieves excellent visual outcomes for refractive error correction. With femtosecond laser, small incision lenticule extraction (SMILE) is an increasingly viable alternative to laser-assisted in situ keratomileusis (LASIK). Comparative studies demonstrate similar efficacy and predictability between SMILE and LASIK, making it difficult for clinicians to choose which to use. This review thus compares femtosecond-LASIK (FS-LASK) and SMILE in various scenarios, to assist clinicians in deciding which refractive surgery procedure to recommend. RECENT FINDINGS SMILE may be superior for highly myopic eyes due to a smaller decrease in functional optical zone. SMILE further induces less spherical aberration and less overall higher order aberrations in mesopic conditions. SMIILE also has less postoperative dry eye, making it suitable those with preexisting dry eye. For low to moderate myopic astigmatism correction, FS-LASIK has less undercorrection compared to SMILE. Lastly, SMILE has not yet received Food and Drug Administration or Conformité Européenne approval for hyperopic correction, rendering FS-LASIK the choice of procedure for hyperopic correction. SUMMARY Both FS-LASIK and SMILE demonstrate good efficacy and predictability. Understanding specific clinical scenarios where one may be superior to the other will aid clinicians in choosing the most suitable procedure for personalized care.
Collapse
|
2
|
Chow AHY, Mungalsingh MA, Thai D, Selimos Z, Yan SK, Xu H, Jones DA. Suitability of multifunction devices Myah and Myopia Master for monitoring myopia progression in children and adults. Ophthalmic Physiol Opt 2024; 44:1017-1030. [PMID: 38760986 DOI: 10.1111/opo.13332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 04/22/2024] [Accepted: 04/28/2024] [Indexed: 05/20/2024]
Abstract
PURPOSE To assess the feasibility of using multifunction instruments to measure axial length for monitoring myopia progression in children and adults. METHODS Axial length was measured in 60 children (aged 6-18 years) and 60 adults (aged 19-50 years) with multifunction instruments (Myah and Myopia Master) and stand-alone biometers (Lenstar LS900 and IOLMaster 700). Repeatability (measurements by the same examiner) and reproducibility (measurements by different examiners) were computed as the within-subject standard deviation (Sw) and 95% limits of agreement (LoA). Inter-instrument agreement was computed as intraclass correlation coefficients. The threshold for detecting myopic progression was taken as 0.1 mm. Measures were repeated only in children following the administration of 1% tropicamide to determine the impact of cycloplegia on axial length. RESULTS Overall, the IOLMaster 700 had the best repeatability in children (0.014 mm) and adults (0.009 mm). Repeatability Sw values for all devices ranged from 0.005 to 0.021 mm (children) and 0.003 to 0.016 mm (adults). In children, reproducibility fell within 0.1 mm 95% of the time for the Myah, Myopia Master and IOLMaster 700. Agreement among all devices was classified as excellent (ICC 0.999; 95% CI 0.998-0.999), but the 95% LoA among the Myah, Myopia Master and Lenstar LS900 was ≥0.1 mm. Cycloplegia had no statistically significant effect on axial length (all p > 0.13). CONCLUSIONS The Myah and Myopia Master multifunction instruments demonstrated good repeatability and reproducibility, and their accuracy was comparable to stand-alone biometers. Axial length measurements using different instruments can be considered interchangeable but should be compared with some caution. Accurate axial length measurements can be obtained without cycloplegia. The multifunction instruments Myah and Myopia Master are as well suited for monitoring myopia progression in children as the stand-alone biometers IOLMaster 700 and Lenstar LS900.
Collapse
|
3
|
Schaeffel F, Swiatczak B. Mechanisms of emmetropization and what might go wrong in myopia. Vision Res 2024; 220:108402. [PMID: 38705024 DOI: 10.1016/j.visres.2024.108402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 03/25/2024] [Accepted: 03/25/2024] [Indexed: 05/07/2024]
Abstract
Studies in animal models and humans have shown that refractive state is optimized during postnatal development by a closed-loop negative feedback system that uses retinal image defocus as an error signal, a mechanism called emmetropization. The sensor to detect defocus and its sign resides in the retina itself. The retina and/or the retinal pigment epithelium (RPE) presumably releases biochemical messengers to change choroidal thickness and modulate the growth rates of the underlying sclera. A central question arises: if emmetropization operates as a closed-loop system, why does it not stop myopia development? Recent experiments in young human subjects have shown that (1) the emmetropic retina can perfectly distinguish between real positive defocus and simulated defocus, and trigger transient axial eye shortening or elongation, respectively. (2) Strikingly, the myopic retina has reduced ability to inhibit eye growth when positive defocus is imposed. (3) The bi-directional response of the emmetropic retina is elicited with low spatial frequency information below 8 cyc/deg, which makes it unlikely that optical higher-order aberrations play a role. (4) The retinal mechanism for the detection of the sign of defocus involves a comparison of defocus blur in the blue (S-cone) and red end of the spectrum (L + M-cones) but, again, the myopic retina is not responsive, at least not in short-term experiments. This suggests that it cannot fully trigger the inhibitory arm of the emmetropization feedback loop. As a result, with an open feedback loop, myopia development becomes "open-loop".
Collapse
|
4
|
Schaeffel F, Wildsoet CF. Red light therapy for myopia: Merits, risks and questions. Ophthalmic Physiol Opt 2024; 44:801-807. [PMID: 38563650 DOI: 10.1111/opo.13306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Revised: 02/29/2024] [Accepted: 03/14/2024] [Indexed: 04/04/2024]
|
5
|
Yii F, Strang N, Bernabeu MO, Dhillon B, MacGillivray T. Corneal biomechanics are not exclusively compromised in high myopia. Ophthalmic Physiol Opt 2024; 44:977-986. [PMID: 38563586 DOI: 10.1111/opo.13313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 03/15/2024] [Accepted: 03/22/2024] [Indexed: 04/04/2024]
Abstract
INTRODUCTION Research assuming linearity has concluded that corneal biomechanics are compromised in high myopia. We investigated whether this assumption was appropriate and re-examined these associations across different levels of myopia. METHODS Myopic (spherical equivalent refraction, SER ≤ -0.50 D) eyes of 10,488 adults aged 40-69 years without any history of systemic and ocular conditions were identified in the UK Biobank. Ordinary least squares (OLS) regression was employed to test the linear association between corneal hysteresis (CH) or corneal resistance factor (CRF), separately, and SER while controlling for age, sex, corneal radius and intraocular pressure. Quantile regression (QR) was used to test the same set of associations across 49 equally spaced conditional quantiles of SER. RESULTS In OLS regression, each standard deviation (SD) decrease in CH and CRF was associated with 0.08 D (95% CI: 0.04-0.12; p < 0.001) and 0.10 D (95% CI: 0.04-0.15; p < 0.001) higher myopia, respectively. However, residual analysis indicated that the linearity assumption was violated. QR revealed no evidence of a significant association between CH/CRF and SER in low myopia, but a significant (p < 0.05) positive association became evident from -2.78 D (0.06 and 0.08 D higher myopia per SD decrease in CH and CRF). The magnitude of association increased exponentially with increasing myopia: in the -5.03 D quantile, every SD decrease in CH and CRF was associated with 0.17 D (95% CI: 0.08-0.25; p < 0.001) and 0.21 D (95% CI: 0.10-0.31; p < 0.001) higher myopia. In the -8.63 D quantile, this further increased to 0.54 D (95% CI: 0.33-0.76; p < 0.001) and 0.67 D (95% CI: 0.41-0.93; p < 0.001) higher myopia per SD decrease in CH and CRF. CONCLUSIONS Corneal biomechanics appeared compromised from around -3.00 D. These changes were observed to be exponential with increasing myopia.
Collapse
|
6
|
Lanca C, Pan CW, Grzybowski A. Anti-myopia Spectacles: The Standard of Care in the Future? Am J Ophthalmol 2024; 263:xi-xiii. [PMID: 38423201 DOI: 10.1016/j.ajo.2024.02.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 01/31/2024] [Accepted: 02/18/2024] [Indexed: 03/02/2024]
|
7
|
Abing AA, Oh A, Ong LF, Marvasti AH, Tran DB, Lee JK. Surgical options and clinical outcomes for high myopia. Curr Opin Ophthalmol 2024; 35:284-291. [PMID: 38700946 DOI: 10.1097/icu.0000000000001053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2024]
Abstract
PURPOSE OF REVIEW Higher degrees of myopia are currently being treated with refractive surgery. However, there is limited characterization and outcomes data for this cohort. This article aims to review the literature on highly myopic patients who had refractive surgery and present a retrospective analysis of 149 patients (270 eyes) with high to extreme myopia (≤-5.0D SE) who underwent refractive surgery [laser-assisted subepithelial keratomileusis (LASIK), photorefractive keratectomy (PRK), or implantable collamer lense (ICL)] at a single practice. RECENT FINDINGS There is substantial literature on the efficacy of LASIK, PRK, and phakic intraocular lenses for refractive error correction, but a dearth of studies on patients with high to extreme myopia undergoing different types of refractive surgery. Our study reveals that this cohort of patients has excellent outcomes with minimal complications. SUMMARY Our study reveals that the average preoperative myopia was highest in ICL patients (-10.03D), followed by PRK (-7.21D), and LASIK (-7.04D) patients. Not surprisingly, eyes with high myopia and thin corneas were offered and elected ICLs for their procedure. Highly myopic patients achieved outcomes consistent with data reported in the literature- average postoperative uncorrected visual acuity was 20/20 for LASIK and ICL eyes and 20/25 for PRK eyes.
Collapse
|
8
|
Swiatczak B, Schaeffel F. Effects of short-term exposure to red or near-infrared light on axial length in young human subjects. Ophthalmic Physiol Opt 2024; 44:954-962. [PMID: 38557968 DOI: 10.1111/opo.13311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 03/19/2024] [Accepted: 03/20/2024] [Indexed: 04/04/2024]
Abstract
PURPOSE To determine whether visible light is needed to elicit axial eye shortening by exposure to long wavelength light. METHODS Incoherent narrow-band red (620 ± 10 nm) or near-infrared (NIR, 875 ± 30 nm) light was generated by an array of light-emitting diodes (LEDs) and projected monocularly in 17 myopic and 13 non-myopic subjects for 10 min. The fellow eye was occluded. Light sources were positioned 50 cm from the eye in a dark room. Axial length (AL) was measured before and after the exposure using low-coherence interferometry. RESULTS Non-myopic subjects responded to red light with significant eye shortening, while NIR light induced minor axial elongation (-13.3 ± 17.3 μm vs. +6.5 ± 11.6 μm, respectively, p = 0.005). Only 41% of the myopic subjects responded to red light exposure with a decrease in AL and changes were therefore, on average, not significantly different from those observed with NIR light (+0.2 ± 12.1 μm vs. +1.1 ± 11.2 μm, respectively, p = 0.83). Interestingly, there was a significant correlation between refractive error and induced changes in AL after exposure to NIR light in myopic eyes (r(15) = -0.52, p = 0.03) and induced changes in AL after exposure to red light in non-myopic eyes (r(11) = 0.62, p = 0.02), with more induced axial elongation with increasing refractive error. CONCLUSIONS Incoherent narrow-band red light at 620 nm induced axial shortening in 77% of non-myopic and 41% of myopic eyes. NIR light did not induce any significant changes in AL in either refractive group, suggesting that the beneficial effect of red laser light therapy on myopia progression requires visible stimulation and not simply thermal energy.
Collapse
|
9
|
Ding C, Mao D, Li X, Huang Y, Hou F, Chen H, Bao J. Peripheral myopic defocus signal affects the efficiency of visual information processing in myopic children. Ophthalmic Physiol Opt 2024; 44:1010-1016. [PMID: 38699881 DOI: 10.1111/opo.13325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 04/19/2024] [Accepted: 04/20/2024] [Indexed: 05/05/2024]
Abstract
PURPOSE Spectacle lenses with peripheral lenslets have shown promise for myopia control by providing peripheral myopic defocus signals. Here, we aimed to investigate the impact of prolonged exposure (>6 months) to peripheral myopic defocus on visual information processing in myopic children. METHODS The study included 30 myopic children who habitually wore spectacle lenses with highly aspherical lenslets (HAL group) and 34 children who habitually wore single-vision (SV group) spectacles. The quick contrast sensitivity function (qCSF) was used to measure contrast sensitivity (CS) under conditions of no or high noise. Both groups were tested with HAL and SV lenses. The perceptual template model was utilised to fit the contrast sensitivity function (CSF) and determine differences in information processing efficiency through internal additive noise (N add ) and perceptual template gain (β). RESULTS The areas under the log CSF in the SV group were significantly higher than for the HAL group in both zero-noise conditions with the SV test lens (p = 0.03) and high-noise conditions with the HAL test lens (p = 0.02). For 2 cycle per degree (cpd) stimuli, β was significantly higher in the SV group with the HAL test lens than in the HAL group (p = 0.02), while there was a trend towards a significant difference in β for 6 cpd stimuli (p = 0.07). However, there were no significant differences inN add between the two groups, with or without noise interference. CONCLUSION The reduced CS observed in myopic children wearing HAL lenses for 6 months or more may be due to decreased β. This suggests that prolonged use of spectacle lenses with peripheral myopic defocus signals may compromise the central visual system's ability to process additional external noise, resulting in decreased efficiency in visual information processing.
Collapse
|
10
|
Jiang DD, Zhao CP, Ding WZ, Leng L. [The role of peripheral retinal defocus in myopia progression]. [ZHONGHUA YAN KE ZA ZHI] CHINESE JOURNAL OF OPHTHALMOLOGY 2024; 60:541-546. [PMID: 38825954 DOI: 10.3760/cma.j.cn112142-20231024-00173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2024]
Abstract
The increasing incidence of myopia has become a global public health concern. Exploring the mechanisms underlying the onset and progression of myopia is crucial for prevention and control. This paper reviews the role of peripheral retinal defocus mechanisms in the development of myopia, with particular emphasis on the interaction between accommodation lag and peripheral retinal defocus, as well as the impact of optical intervention on myopia control effectiveness. In recent years, researchers have developed various optical tools for myopia prevention and control based on the peripheral retinal defocus theory, such as peripheral defocus spectacle lenses, orthokeratology lenses, and peripheral defocus soft contact lenses. This paper aims to provide clinicians with the latest research findings to deepen their understanding of the mechanisms involved in myopia development and to guide the future development and clinical application of myopia prevention and control products.
Collapse
|
11
|
Wu W, Wang Y, Chen J, Zhang F. The biomechanical proteins different between low myopic corneas and moderate to high myopic corneas in human. Cont Lens Anterior Eye 2024; 47:102134. [PMID: 38472014 DOI: 10.1016/j.clae.2024.102134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Revised: 02/20/2024] [Accepted: 03/01/2024] [Indexed: 03/14/2024]
Abstract
PURPOSE To explore the biomechanical proteins different between low myopic corneas and moderate to high myopic corneas. METHODS A total of 27 myopic corneas were used for the Tandem Mass Tag (TMT) proteomics analysis. Differentially expressed proteins (DEPs) were clustered with fold changes > 1.20 or < 0.83 and p < 0.05. Proteins and Proteins Interactions (PPIs) were conducted to find hub proteins; Uniprot database was to screen proteins with biomechanical functions, and Parallel Reaction Monitoring (PRM) was performed to verify the TMT results. Pearson analysis was used to reveal the correlations between myopic degrees and biomechanical proteins. The Immunofluorescence (IF) staining was used to observe the protein distributions. RESULTS In total, 34 DEPs were observed between moderate myopic corneas and low myopic corneas; 103 DEPs were observed between high myopic corneas and low myopic corneas, 20 proteins overlapped. The PPIs analysis showed keratin 2, keratins 10 and PRSS1 were hub proteins. The Uniprot function analysis suggested keratin 2 and keratin 10 exhibited biomechanical functions. The PRM demonstrated keratin 2 and keratin 10 levels were significantly lower in moderate and high myopic corneas, which was consistent with the TMT proteomics results. IF staining also demonstrated keratin 2 and keratin 10 were less distributed in moderate and high myopic corneas than in low myopic corneas. CONCLUSIONS The levels of biomechanical proteins keratin 2 and keratin 10 are significantly lower in moderate and high myopic corneas than in low myopic corneas.
Collapse
|
12
|
Yang B, Liu L, Cho P. Effectiveness of orthokeratology and myopia control spectacles in a real-world setting in China. Cont Lens Anterior Eye 2024; 47:102167. [PMID: 38609791 DOI: 10.1016/j.clae.2024.102167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 04/04/2024] [Accepted: 04/08/2024] [Indexed: 04/14/2024]
Abstract
OBJECTIVE To compare the effectiveness of myopia control in Chinese children, who had been wearing either orthokeratology (ortho-k) lenses or myopia control spectacles (MCS) for one year. METHODS Relevant data were retrieved from 212 patients, with baseline myopia of -5.00 to -0.75 D, astigmatism ≤ 1.50 D, who had been undergoing myopia control treatment with either ortho-k (Euclid (OK1) or CRT (OK2)) or MCS (Stellest (MCS1) or DIMS (MCS2)) for at least one year. Myopia control effectiveness among the four groups was compared based on the change in spherical equivalent refraction (SER) (for the spectacle groups) and axial length (AL) (for all groups). Data retrieved, from the right eye only, included best corrected visual acuity (BCVA), SER, and AL at both the initial clinic visit (baseline) and the one-year visit was analysed. RESULTS Although no significant differences in gender, cylindrical power, or BCVA were observed at the baseline visit (P > 0.05), there were significant differences in baseline age, myopia, and AL among the four groups (P < 0.05). No significant difference in axial elongation (AE) was found among the four groups after one year of treatment (P = 0.49). AE, adjusted for baseline age and spherical power, were 0.19 ± 0.15, 0.18 ± 0.14, 0.19 ± 0.19, 0.20 ± 0.18 mm for OK1, OK2, MCS1, MCS2, respectively. Only age was a significantly factor associated with AE and SER increase (P < 0.05), with negative associations between AE and age in all groups and positive association between SER increase and baseline age in the spectacle groups observed. CONCLUSION Both brands of ortho-k lenses and MCS had similar myopia control effectiveness for mild to moderate myopic children treated in a real-world setting in China. Average AE in one year ranged from 0.18 to 0.20 mm, comparable to previous reports on myopia control using ortho-k.
Collapse
|
13
|
Wu J, Zhang X, Wang L, Zhang P, Guo X, Xie P. Altering optical zone diameter, reverse curve width, and compression factor: impacts on visual performance and axial elongation in orthokeratology. Cont Lens Anterior Eye 2024; 47:102136. [PMID: 38503665 DOI: 10.1016/j.clae.2024.102136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 02/08/2024] [Accepted: 03/04/2024] [Indexed: 03/21/2024]
Abstract
PURPOSE To investigate the effects of modifications in back optical zone diameter (BOZD), reverse curve width (RCW), and compression factor (CF) on refractive error changes and axial elongation in myopic children undergoing orthokeratology (ortho-k) over a 12-month period. METHOD In this retrospective study, data from 126 myopic children undergoing ortho-k fitting were analyzed. Subjects were categorized into four distinct groups based on lens design parameters: Group A (BOZD 6.0 mm, RCW 0.6 mm, CF 0.75 D); Group B (BOZD 6.0 mm, RCW 0.6 mm, CF 1.25 D); Group C (BOZD 5.4 mm, RCW 0.9 mm, CF 1.25 D); and Group D (BOZD 5.0 mm, RCW 1.1 mm, CF 1.25 D). The study evaluated uncorrected visual acuity (UCVA), corneal topography, and axial length (AL) at intervals, using Linear Mixed Models (LMMs) for time-based changes, and ANOVA or Kruskal-Wallis tests for group differences in AL elongation. A multivariable regression analysis identified factors independently associated with AL elongation. RESULTS Within the first day and week, all four groups displayed significant improvements in UCVA and alterations in corneal curvature, which subsequently stabilized. Although UCVA variations between groups were subtle, Group D had less corneal curvature change than Groups A and B initially and exhibited significantly less AL elongation after one year. No significant difference in corneal curvature change or AL elongation was observed between Group C and the other groups. Multiple regression analysis indicated that older baseline age, greater baseline spherical equivalent refractive error, and smaller BOZD were associated with less AL elongation. CONCLUSION The study reveals a positive correlation between BOZD and axial length growth over the 12-month period. A pure 0.5 D CF increment demonstrates a nonsignificant impact. This study provides new ideas into optimizing the parameters of ortho-k lenses.
Collapse
|
14
|
Pan X, Wang Y, Li Z, Ye Z. Intraocular Lens Power Calculation in Eyes After Myopic Laser Refractive Surgery and Radial Keratotomy: Bayesian Network Meta-analysis. Am J Ophthalmol 2024; 262:48-61. [PMID: 37865389 DOI: 10.1016/j.ajo.2023.09.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 08/17/2023] [Accepted: 09/27/2023] [Indexed: 10/23/2023]
Abstract
PURPOSE To compare the accuracy of formulas for calculating intraocular lens power in eyes after myopic laser refractive surgery or radial keratotomy. DESIGN Bayesian network meta-analysis. METHODS PubMed, Embase, the Cochrane Data Base of Systematic Reviews, and the Cochrane Central Register of Controlled Trials databases were searched for retrospective and prospective clinical studies published from January 1, 2012, to August 24, 2022. The outcome measurement was the percentage of eyes with a predicted error within the target refractive range (±0.50 diopter [D] or ±1.00 D). RESULTS Our meta-analysis includes 24 studies of 1172 eyes after myopic refractive surgery that use 12 formulas for intraocular lens power calculation. (1) A network meta-analysis showed that Barrett true-K no history, the optical coherence tomography (OCT) formula, and the Masket formula had a significantly higher percent of eyes within ±0.50 D of the goal than the Haigis-L formula, whereas the Wang-Koch-Maloney formula showed the poor predictability. Using an error criterion of within ±1.00 D, the same 3 formulas performed slightly better than the Haigis-L formula. Based on performance using both prediction error criteria, the Barrett true-K no history formula, OCT formula, and Masket formula showed the highest probability of ranking as the top 3 among the 12 methods. (2) A direct meta-analysis with a subset of 4 studies and 5 formulas indicated that formulas did not differ in percent success for either the ±0.5 D or ±1.0 D error range in eyes that had undergone radial keratotomy. CONCLUSIONS The OCT, Masket, and Barrett true-K no history formulas are more accurate for eyes with previous myopic laser refractive surgery, whereas no significant difference was found among the formulas for eyes that had undergone radial keratotomy.
Collapse
|
15
|
Zhu S, Song Y, Yang B, Wang X, Ma W, Dong G, Liu L. The relationship between accommodative and binocular function with myopia progression in myopic children undergoing orthokeratology. Cont Lens Anterior Eye 2024; 47:102171. [PMID: 38631934 DOI: 10.1016/j.clae.2024.102171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 04/11/2024] [Accepted: 04/11/2024] [Indexed: 04/19/2024]
Abstract
PURPOSE To determine the relationship between changes in accommodative and binocular function with myopia progression in myopic children over a two-year follow-up period, and to determine when changes in visual functions stabilized after switching from spectacles to orthokeratology (Ortho-K). METHODS This prospective, self-controlled study followed thirty-six participants (aged 8-14 years) for two years after they switched from spectacles to Ortho-K. Accommodative and binocular function were assessed prior to and 1, 3, 6, 12, 18 and 24 months after commencing Ortho-K. Measurements included accommodative amplitude, accommodative response, accommodative facility, accommodative convergence/accommodation (AC/A), ocular alignment, positive relative accommodation (PRA), negative relative accommodation (NRA), horizontal vergence range, reading ability and stereoacuity. Myopia progression was quantified by the change in axial length. RESULTS Ocular alignment, monocular and binocular accommodative facility, and PRA stabilized after 1 month. The distance blur point in the convergence range, the distance break and recovery point in the divergence range, accommodative amplitude, calculated AC/A, stereoacuity and reading ability stabilized within 6 months. After two years of Ortho-K, NRA significantly increased (p = 0.044), while it showed no significant difference after one-year of lens wear (p = 0.49). The distance break point in the convergence range showed no significant difference (p = 0.20), but significantly decreased after one-year (p = 0.005). There were no significant correlations between the change in axial length with changes in accommodative or binocular function (p > 0.05). CONCLUSION Accommodative and binocular function changed significantly after switching from spectacles to Ortho-K and most of the parameters stabilized within the first 6 months. There was no association between the change in accommodative or binocular function and myopia progression.
Collapse
|
16
|
Wang Z, Li M, Ji H, Chen H, Sang A, Cheng X, Li J, Yu Y. Comparison of risk factors for OBL in FS-LASIK and SMILE correction for myopia and myopia astigmatism. Graefes Arch Clin Exp Ophthalmol 2024; 262:1925-1931. [PMID: 38091059 DOI: 10.1007/s00417-023-06336-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 10/26/2023] [Accepted: 11/30/2023] [Indexed: 05/22/2024] Open
Abstract
BACKGROUND To find out the incidence and risk factors of opaque bubble layer (OBL) in eyes with myopia and myopic astigmatism following femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE). METHODS A total of 1076 eyes from 569 patients who had FS-LASIK or SMILE were included in the retrospective research. For each kind of surgery, eyes were separated into two groups: "OBL" groups and "no OBL" groups. In the FS-LASIK group, eyes that developed OBL were split into "hard OBL" and "soft OBL" groups. The incidence and size of OBL were analyzed after watching the surgical procedure videotaped during the operation and taking screenshots. Surgical parameters, including sphere, cylinder, keratometry, corneal thickness, flap thickness, cap thickness, lenticule thickness, and visual acuity, were compared. RESULTS In the FS-LASIK surgery, the incidence of OBL was 63.2% (347 eyes). A thicker central corneal thickness (CCT) was the only independent risk factor affecting the OBL area (β = 0.126, P = 0.019). One hundred and thirty of these eyes had hard OBL, and the flap thickness of these eyes was thinner than that of those with soft OBL (P = 0.027). In the SMILE group, 26.6% (140 eyes) developed OBL. A higher flat keratometry (K) and a thicker residual stromal thickness (RST) were risk factors affecting the OBL area (β = 0.195, P = 0.024; β = 0.281, P = 0.001). CONCLUSION The incidence of OBL differs between the FS-LASIK surgery and the SMILE surgery. There are differences in the factors influencing OBL between the two surgeries.
Collapse
|
17
|
Tang T, Lu Y, Li X, Zhao H, Wang K, Li Y, Zhao M. Comparison of the long-term effects of atropine in combination with Orthokeratology and defocus incorporated multiple segment lenses for myopia control in Chinese children and adolescents. Eye (Lond) 2024; 38:1660-1667. [PMID: 38418604 PMCID: PMC11156845 DOI: 10.1038/s41433-024-02987-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 01/13/2024] [Accepted: 02/05/2024] [Indexed: 03/01/2024] Open
Abstract
PURPOSE The aim of this study was to evaluate the efficacy of Orthokeratology (Ortho-K), defocus incorporated multiple segment (DIMS) lens, combined Ortho-K/atropine, and combined DIMS/atropine for myopia control in children. METHODS A retrospective study included 167 myopic children aged 6-14 years with a spherical equivalent refraction (SER) of -0.75 to -4.00 diopter treated with Ortho-K (OK, n = 41), combined Ortho-K/atropine (OKA, n = 43), DIMS (n = 41), or combined DIMS/atropine (DIMSA, n = 42). Axial length (AL) was measured at baseline and at 3, 6, 9 and 12 months. Axial elongation over time and between groups were analysed. RESULTS After 12 months, the AL change was 0.20 ± 0.12 mm, 0.12 ± 0.14 mm, 0.22 ± 0.14 mm, and 0.15 ± 0.15 mm in the OK, OKA, DIMS, and DIMSA, respectively. There was no significant difference in AL change between OK and DIMS. OKA and DIMSA significantly slowed axial elongation compared to OK and DIMS monotherapy. After stratification by age, in the subgroup aged 6-10 years, there was significant difference in AL change between OKA and DIMS (p = 0.013), and no difference between other groups, while in the subgroup aged 10-14 years, the difference between OKA and DIMS became insignificant (p = 0.237), and the difference between OK and OKA, OK and DIMSA, DIMS and DIMSA became significant. CONCLUSIONS Ortho-K and DIMS lenses show similar reductions in myopia progression among children with low initial myopia. Atropine can significantly improve the efficacy of myopia control of both Ortho-K and DIMS lenses, and this add-on effect is better in older children.
Collapse
|
18
|
Batres L, Valdes-Soria G, Romaguera M, Carracedo G. Accommodation response and spherical aberration during 1-Year of orthokeratology lens wear and after discontinuation. Cont Lens Anterior Eye 2024; 47:102133. [PMID: 38467534 DOI: 10.1016/j.clae.2024.102133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 02/21/2024] [Accepted: 03/01/2024] [Indexed: 03/13/2024]
Abstract
BACKGROUND To assess accommodation and spherical aberration changes during one year of orthokeratology lens wear and one month after lens cessation. METHODS A prospective, randomized, longitudinal study was conducted on forty-seven young healthy subjects at the Optometry Clinic of the Complutense University of Madrid (Spain). Non-cycloplegic refraction, high and low uncorrected visual acuity, high and low best corrected visual acuity, accommodative lag, horizontal near phoria, corneal topography, and high-order aberrations were performed at baseline, 1-day, 1-week, 1-, 6- and 12-months of lens wear and after one month of wash out period. p < 0.05 was considered as statistically significant. RESULTS Spherical equivalent refraction (SE) was -3.23 ± 1.57D at baseline and -0.36 ± 0.64D after 12-months of lens wear, while accommodative lag changed from 0.53 ± 0.39D to 0.15 ± 0.29D after one year of lens wear. No significant differences were found when comparing SE at baseline and after one month of lens cessation (p > 0.05). A high correlation was found between the accommodative lag at baseline and after 12 M of lens wear. 22 out of 25 subjects with exophoria at baseline showed a significant reduction in the deviation at 12-months (p < 0.05). Total spherical aberration increased during all visits due to the lens wear (p < 0.05) although internal spherical aberration showed a significant decrease for 1-week, 1-month and 12-month visits (p < 0,05). CONCLUSION Orthokeratology lenses may change the accommodative response of the patient as a reduction on accommodative lag on exophoric patients and an overall increase on the internal spherical aberrations was found during treatment but return to nearly baseline values when cessation.
Collapse
|
19
|
Xiong J, Xu J, Zhou M, Liu J, Wang Q, Yin X, Deng Y, Luo X, Wang N, Gui F, Yu K, Liu J, Zhu Z, Cheng C, Yu Y. Mesopic pupil indices as potential risk factors for glare disability after intraocular implantable collamer lens implantation: prospective study. J Cataract Refract Surg 2024; 50:565-571. [PMID: 38350161 PMCID: PMC11146185 DOI: 10.1097/j.jcrs.0000000000001420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 12/18/2023] [Accepted: 02/01/2024] [Indexed: 02/15/2024]
Abstract
PURPOSE To explore the influence of preoperative factors, including varying pupil sizes and refractive attributes, on postoperative glare disability in patients undergoing implantable collamer lens (ICL) implantation. SETTING Second Affiliated Hospital, Nanchang University, Nanchang, Jiangxi, China. DESIGN Prospective observational study. METHODS The preoperative ocular characteristics and 6-month postoperative glare status in eligible patients who underwent EVO-Visian ICL V4c (VICMO) implantation were analyzed. The glare disability criteria encompassed a glare symptom score >6 and glare sensitivity exceeding 1:2.7. Logistic regression analysis was used to explore the relationship between the preoperative ocular parameters and post-ICL glare. RESULTS The study included 95 patients (mean age, 26.04 ± 6.29 years), comprising 30 men (58 eyes) and 65 women (129 eyes). Multivariate analysis revealed a significant correlation between postoperative glare disability and increased spherical power in preoperative mesopic pupils (β = -0.124, P = .039), as well as elevated cylinder power in preoperative mesopic (β = -0.412, P = .009) and photopic pupils (β = -0.430, P = .007). Moreover, a larger preoperative mesopic pupil diameter (β = 0.561, P = .005) demonstrated a significant correlation with glare disability. CONCLUSIONS Preoperative mesopic pupil dimensions and associated refractive parameters, such as sphere and cylinder, were correlated with glare disability, including the cylinder aspect in photopic pupils, which can assist clinicians in optimizing preoperative selection for ICL implantation, aiding in the anticipation of potential glare disability risks.
Collapse
|
20
|
Huang Y, Zhan B, Han T, Zhou X. Effective optical zone following small incision lenticule extraction: a review. Graefes Arch Clin Exp Ophthalmol 2024; 262:1657-1665. [PMID: 37851133 DOI: 10.1007/s00417-023-06263-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Revised: 08/18/2023] [Accepted: 10/01/2023] [Indexed: 10/19/2023] Open
Abstract
Small incision lenticule extraction (SMILE) is a "flapless" keratorefractive surgery with excellent safety, efficacy, stability, and predictability for myopia correction. A recent global multicenter study also reported good refractive outcomes for hyperopic SMILE. SMILE has shown advantages including improved biomechanical strength, fewer dry eye symptoms, less corneal denervation, and fewer surgery-induced higher-order aberrations over laser in situ keratomileusis (LASIK). However, night vision complaints, including glare, halos, and starbursts, could still occur after SMILE. These symptoms have been proven to be closely related to the effective optical zone (EOZ), which is defined as the achieved area of corneal ablation. A larger postoperative EOZ may indicate better visual quality, making EOZ an important safety parameter for keratorefractive surgeries. As SMILE has gained wider application globally, the EOZ following SMILE has also been increasingly studied in the field of refractive surgery. This review provides an update on topics related to the EOZ after SMILE, including its measurement and influencing factors, aiming to benefit the personalization of the surgical algorithm and ultimately improve the visual quality after the SMILE procedure.
Collapse
|
21
|
Zhang H, Yang P, Li Y, Zhang W, Li S. Effect of Low-Concentration Atropine Eye Drops in Controlling the Progression of Myopia in Children: A One- and Two-Year Follow-Up Study. Ophthalmic Epidemiol 2024; 31:240-248. [PMID: 37528608 DOI: 10.1080/09286586.2023.2232462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2022] [Revised: 05/14/2023] [Accepted: 06/25/2023] [Indexed: 08/03/2023]
Abstract
PURPOSE Atropine eye drops have been shown to slow the progression of myopia, but there has been limited research on the effectiveness of 0.05% atropine in treating myopia. This study aimed to investigate the safety and efficacy of 0.05% atropine eye drops in controlling myopia in children. METHODS The study included 424 participants aged 6 to 12 years between January 1, 2015, and January 1, 2021. Of these, 213 were randomly assigned to the 0.05% atropine group and 211 to the placebo group. The cycloplegic spherical equivalent (SE), axial length (AL), corneal curvature (K), and anterior chamber depth (ACD) were measured using IOLMaster. The lens power and corneal astigmatism were also determined. The changes in ocular biometric parameters were compared between the two groups, and the contributions of ocular characteristics to SE progression were calculated and compared. RESULTS Over a 12-month period, the changes in spherical equivalent were -0.03 ± 0.28 and -0.32 ± 0.14 in the atropine and placebo groups, respectively (P = .01). The changes in axial length were 0.06 ± 0.11 and 0.17 ± 0.12, respectively (P = .01). At 18 and 24 months, there were significant differences in axial length and spherical equivalent between the atropine and placebo groups. Multiple regression models accounting for changes in AL, K, and lens magnification explained 87.23% and 98.32% of SE changes in the atropine and placebo groups, respectively. At 1 year (p = .01) and 2 years (p = .03), there were significant differences in photophobia between the atropine and placebo groups. CONCLUSIONS This two-year follow-up study demonstrates that 0.05% atropine eye drops are safe and effective in preventing the development of myopia in school-aged children.
Collapse
|
22
|
Chen T, Li N, Ge T, Lin Y, Wu X, Gao H, Liu M. Regional analysis of posterior corneal elevation after laser refractive surgeries for correction of myopia of different degrees. Indian J Ophthalmol 2024; 72:824-830. [PMID: 38317325 DOI: 10.4103/ijo.ijo_2127_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Accepted: 10/19/2023] [Indexed: 02/07/2024] Open
Abstract
PURPOSE To evaluate regional changes in the posterior corneal elevation after three laser refractive surgeries for correction of myopia of different degrees. SETTINGS AND DESIGN Retrospective, comparative, and non-randomized study. METHODS Two hundred patients (200 eyes) who underwent laser epithelial keratoplasty (LASEK), femtosecond-assisted laser in-situ keratomileusis (FS-LASIK), and small-incision lenticule extraction (SMILE) were included in this study. According to preoperative spherical equivalent (SE), each surgical group was divided into two refractive subgroups: low-to-moderate myopia (LM group) and high myopia (H group). The posterior corneal elevation from Pentacam Scheimpflug tomography was analyzed preoperatively and at 1 month, 3 months, 6 months, and 12 months postoperatively. Three subregions of the posterior cornea were divided in this study as the central, paracentral, and peripheral regions. STATISTICAL ANALYSIS USED Generalized Estimating Equations (GEE). RESULTS For all three surgical groups, similar changing trends were seen in the two refractive subgroups. H group presented a larger changing magnitude than the LM group in FS-LASIK over time ( P < 0.05), whereas no significant difference was noted in the two refractive subgroups of LASEK or SMILE ( P > 0.05). At 12 months postoperatively, the central posterior corneal elevation returned to the preoperative level in LASEK ( P > 0.05) but shifted forward significantly in FS-LASIK and SMILE ( P < 0.05). CONCLUSION Different posterior corneal regions respond differently to corneal refractive surgeries. LASEK, FS-LASIK, and SMILE demonstrate different trends in the regional changes in posterior corneal elevation. The corneal shape seems more stable in LASEK than in FS-LASIK and SMILE.
Collapse
|
23
|
Yang Y, Chen C, Chen Z, Zeng L, Xue F, Zhou J. Redistribution of Epithelium and Stroma and Their Relationship With Corneal Curvature After 1-Month Cessation of Overnight Orthokeratology. Eye Contact Lens 2024; 50:249-254. [PMID: 38687606 DOI: 10.1097/icl.0000000000001085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/31/2024] [Indexed: 05/02/2024]
Abstract
OBJECTIVES To investigate the changes in the thickness of epithelium and stroma and their relationship with corneal curvature following the cessation of overnight orthokeratology for a period of 1 month. METHODS This prospective study consecutively included 20 juveniles (20 right eyes) who had undergone overnight orthokeratology for a minimum of one year and were willing to discontinue the treatment. The study measured and compared epithelial and corneal curvature using optical coherence tomography and Medmont topographer at the first day of cessation and 1 month after cessation. In addition, changes in uncorrected visual acuity and refractive error before and after the cessation of the treatment were analyzed. RESULTS The study found a significant increase in the thickness of the epithelium in the central 2-mm area after the cessation of the treatment (t = -4.807, P <0.001). Moreover, the stroma in the paracentral area (2-5 mm) and peripheral area (5-6 mm) showed a general thinning trend ( P =0.016, P =0.016). Regarding the correlation analysis, the change in central epithelial thickness (ΔCET) was significantly correlated with the change in paracentral corneal curvature (ΔPCCC) (r=0.610, P =0.007) and the change in peripheral corneal curvature (ΔPCC) (r=0.597, P =0.009). Similarly, the change in central stromal thickness (ΔCST) was significantly correlated with the change in central corneal curvature (ΔCCC) (r=0.500, P =0.035), ΔPCCC (r=0.700, P =0.001), and ΔPCC (r=0.635, P =0.005). CONCLUSIONS The study found that the corneal remodeling induced by orthokeratology was reversible after the cessation of the treatment. Specifically, changes in the epithelium were found to be more prominent in the central area, while changes in the stroma were more pronounced in the paracentral and peripheral areas. In addition, the study established a significant correlation between central corneal remodeling and changes in curvature.
Collapse
|
24
|
Martínez-Plaza E, López-de la Rosa A, Molina-Martín A, Piñero DP. Orthokeratology effect on the corneoscleral profile: Beyond the bull's eye. Ophthalmic Physiol Opt 2024; 44:757-768. [PMID: 38240175 DOI: 10.1111/opo.13279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 01/08/2024] [Accepted: 01/09/2024] [Indexed: 05/01/2024]
Abstract
PURPOSE To assess the impact of 3 months of orthokeratology (ortho-k) contact lenses (CLs) for myopia correction on the corneoscleral profile, as changes in scleral geometry could serve as indirect evidence of alteration in the corneal biomechanical properties. METHODS Twenty subjects (40 eyes) were recruited to wear ortho-k lenses overnight; however, after discontinuation (two CL fractures, one under-correction and two non-serious adverse events), 16 subjects (31 eyes) finished a 3-month follow-up. Corneoscleral topographies were acquired using the Eye Surface Profiler (ESP) system before and after 3 months of lens wear. Steep (SimKs) and flat (SimKf) simulated keratometry and scleral sagittal height measurements for 13-, 14- and 15-mm chord lengths were automatically calculated by the ESP software. Additionally, sagittal height and slope were calculated in polar format from 21 radii (0-10 mm from the corneal apex) at 12 angles (0-330°). Linear mixed models were fitted to determine the differences between visits. RESULTS SimKs and SimKf were increased significantly (p ≤ 0.02). The sagittal height in polar format increased significantly (p = 0.046) at a radius of 2.5 mm for 150°, 180°, 210° and 240° orientations and at a radius of 3.0 mm for 210°. Additionally, the slope in polar format significantly decreased (p ≤ 0.04) at radii ranges of 0.0-0.5, 0.5-1.0 and 1.0-1.5 mm for multiple angles and at a radii range of 5.0-5.5 mm for 90°. It also increased significantly (p ≤ 0.045) at a radii range of 1.5-2.0 mm for 30° and at radii ranges of 2.0-2.5, 2.5-3.0 and 3.0-3.5 mm for multiple angles. No significant changes were found for any parameter measured from the scleral area. CONCLUSIONS Three months of overnight ortho-k lens wear changed the central and mid-peripheral corneal geometry as expected, maintaining the peripheral cornea and the surrounding sclera stability.
Collapse
|
25
|
Debellemanière G, Mechleb N, Bernier T, Ancel JM, Gauvin M, Wallerstein A, Saad A, Gatinel D. The Development of a Thick-Lens Post-Myopic Laser Vision Correction Intraocular Lens Calculation Formula. Am J Ophthalmol 2024; 262:40-47. [PMID: 37865388 DOI: 10.1016/j.ajo.2023.09.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 09/18/2023] [Accepted: 09/25/2023] [Indexed: 10/23/2023]
Abstract
PURPOSE To describe the development of the post-myopic laser vision correction (LVC) version of the PEARL-DGS intraocular lens (IOL) calculation formula and to evaluate its outcomes on an independent test set. DESIGN Retrospective, single-center case series. METHODS A modified lens position prediction algorithm was designed along with methods to predict the posterior corneal curvature radius and correct the corneal power measurement error. A different set of previously operated eyes that underwent LVC was used to evaluate the prediction precision of the post-LVC formula. RESULTS Post-LVC PEARL-DGS formula significantly reduced mean absolute error of prediction in comparison to Haigis-L, Shammas, and American Society of Cataract and Refractive Surgery (ASCRS) average formulas (P < .001). It exhibited similar postoperative refractive precision as the Barrett True-K No History formula (P = .61). CONCLUSION The post-LVC formula development process described in this article performed as well as the state-of-the-art post-LVC formula on the present test set. Further studies are required to assess its efficacy in other independent sets.
Collapse
|