1
|
Bozdemir K, Çallıoğlu EE, İslamoğlu Y, Ercan MK, Eser F, Özdem B, Kıraç A, Bayazıt D, Güner R, Babademez MA. Evaluation of the effects of Covid-19 on cochleovestibular system with audiovestibular tests. EAR, NOSE & THROAT JOURNAL 2024; 103:NP267-NP271. [PMID: 34991362 DOI: 10.1177/01455613211069916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
PURPOSE The purpose of the present study was to investigate the effects of COVID-19 on audiovestibular system with Transiently Evoked Distortion Otoacoustic Emissions (TOAE), Distortion Product Otoacoustic Emissions (DPOAE), video head impulse test (vHIT) and caloric test. METHODS Audiovestibular findings of 24 patients with moderate/severe COVID-19 and 24 healthy controls were compared using pure tone audiometry, tympanometry, TOAE, DPOAE, caloric test, and vHIT. RESULTS On audiometry, the pure tone averages of the COVID-19 patients were higher than the controls (P = .038). The TEOAE amplitudes at 4000 and 5000 Hz (P = .006 and P < .01), and DPOAE amplitudes at 3000, 6000, and 8000 Hz (P < .001, P = .003 and P < .001) were significantly lower in COVID-19 patients compared to the controls. On vestibular tests, there was no significant difference between the caloric test results of the patients and the controls (P > .05). On vHIT testing, amplitudes of right semicircular canal was found to be significantly lower in COVID-19 group compared to the control group (P = .008). CONCLUSION COVID-19 may affect inner ear functions causing a subtle damage in the outer hair cells and lateral semicircular canals. It must be kept in mind that COVID-19 may cause cochleovestibular problems.
Collapse
|
2
|
Jedrzejczak WW, Pilka E, Pastucha M, Skarzynski H, Kochanek K. Magnitude of medial olivocochlear reflex assayed by tone-burst-evoked otoacoustic emissions: reliability and comparison with click-evoked emissions. Int J Audiol 2024; 63:293-299. [PMID: 37129585 DOI: 10.1080/14992027.2023.2207116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 04/20/2023] [Indexed: 05/03/2023]
Abstract
OBJECTIVE The purpose of this pilot study was to evaluate the magnitude of the medial olivocochlear reflex (MOCR) estimated by the reduction in tone-burst evoked otoacoustic emissions (TBOAEs) measured at three levels and at three frequencies in response to fixed contralateral white noise. Results were compared with commonly used click-evoked otoacoustic emissions (CEOAEs). DESIGN TBOAEs and CEOAEs, with and without contralateral 60 dB SPL white noise, were measured in response to stimulation at 55, 65, and 75 dB peSPL. In each subject, the set of measurements was performed twice. Of particular interest were the MOCR and its repeatability. STUDY SAMPLE 15 normally hearing persons (13 women, average age 32.3 years, SD = 8.1). RESULTS For both CEOAE and TBOAEs, the reliability of the MOCR was much better for broadband measurements than for half-octave-band filtered estimates. At the same time, the reliability of MOCR in half-octave bands was higher for TBOAEs than for CEOAEs, especially at 2 and 4 kHz. CONCLUSIONS For general applications where broadband MOCR is of interest, the highest magnitude and reliability is provided by CEOAEs. However, TBOAEs may be better if a particular frequency band is of interest.
Collapse
|
3
|
Shera CA. Swept Along: Measuring Otoacoustic Emissions Using Continuously Varying Stimuli. J Assoc Res Otolaryngol 2024; 25:91-102. [PMID: 38409555 PMCID: PMC11018600 DOI: 10.1007/s10162-024-00934-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 01/31/2024] [Indexed: 02/28/2024] Open
Abstract
At the 2004 Midwinter Meeting of the Association for Research in Otolaryngology, Glenis Long and her colleagues introduced a method for measuring distortion-product otoacoustic emissions (DPOAEs) using primary-tone stimuli whose instantaneous frequencies vary continuously with time. In contrast to standard OAE measurement methods, in which emissions are measured in the sinusoidal steady state using discrete tones of well-defined frequency, the swept-tone method sweeps across frequency, often at rates exceeding 1 oct/s. The resulting response waveforms are then analyzed using an appropriate filter (e.g., by least-squares fitting). Although introduced as a convenient way of studying DPOAE fine structure by separating the total OAE into distortion and reflection components, the swept-tone method has since been extended to stimulus-frequency emissions and has proved an efficient and valuable tool for probing cochlear mechanics. One day-a long time coming-swept tones may even find their way into the audiology clinic.
Collapse
|
4
|
Manley GA, Maat B, Begall S, Malkemper P, Caspar KR, Moritz L, van Dijk P. Otoacoustic emissions in African mole-rats. Hear Res 2024; 445:108994. [PMID: 38520899 DOI: 10.1016/j.heares.2024.108994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 03/11/2024] [Accepted: 03/13/2024] [Indexed: 03/25/2024]
Abstract
African mole-rats display highly derived hearing that is characterized by low sensitivity and a narrow auditory range restricted to low frequencies < 10 kHz. Recently, it has been suggested that two species of these rodents do not exhibit distortion product otoacoustic emissions (DPOAE), which was interpreted as evidence for a lack of cochlear amplification. If true, this would make them unique among mammals. However, both theoretical considerations on the generation of DPOAE as well as previously published experimental evidence challenge this assumption. We measured DPOAE and stimulus-frequency otoacoustic emissions (SFOAE) in three species of African mole-rats (Ansell's mole-rat - Fukomys anselli; Mashona mole-rat - Fukomys darlingi; naked mole-rat - Heterocephalus glaber) and found unexceptional otoacoustic emission values. Measurements were complicated by the remarkably long, narrow and curved external ear canals of these animals, for which we provide a morphological description. Both DPOAE and SFOAE displayed the highest amplitudes near 1 kHz, which corresponds to the region of best hearing in all tested species, as well as to the frequency region of the low-frequency acoustic fovea previously described in Ansell's mole-rat. Thus, the cochlea in African mole-rats shares the ability to generate evoked otoacoustic emission with other mammals.
Collapse
|
5
|
Nørgaard KM, Motallebzadeh H, Puria S. The influence of tympanic-membrane orientation on acoustic ear-canal quantities: A finite-element analysis. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:2769-2785. [PMID: 38662609 PMCID: PMC11052631 DOI: 10.1121/10.0025768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 02/23/2024] [Accepted: 04/01/2024] [Indexed: 04/28/2024]
Abstract
Assuming plane waves, ear-canal acoustic quantities, collectively known as wideband acoustic immittance (WAI), are frequently used in research and in the clinic to assess the conductive status of the middle ear. Secondary applications include compensating for the ear-canal acoustics when delivering stimuli to the ear and measuring otoacoustic emissions. However, the ear canal is inherently non-uniform and terminated at an oblique angle by the conical-shaped tympanic membrane (TM), thus potentially confounding the ability of WAI quantities in characterizing the middle-ear status. This paper studies the isolated possible confounding effects of TM orientation and shape on characterizing the middle ear using WAI in human ears. That is, the non-uniform geometry of the ear canal is not considered except for that resulting from the TM orientation and shape. This is achieved using finite-element models of uniform ear canals terminated by both lumped-element and finite-element middle-ear models. In addition, the effects on stimulation and reverse-transmission quantities are investigated, including the physical significance of quantities seeking to approximate the sound pressure at the TM. The results show a relatively small effect of the TM orientation on WAI quantities, except for a distinct delay above 10 kHz, further affecting some stimulation and reverse-transmission quantities.
Collapse
|
6
|
Schilder AGM, Wolpert S, Saeed S, Middelink LM, Edge ASB, Blackshaw H, Pastiadis K, Bibas AG. A phase I/IIa safety and efficacy trial of intratympanic gamma-secretase inhibitor as a regenerative drug treatment for sensorineural hearing loss. Nat Commun 2024; 15:1896. [PMID: 38429256 PMCID: PMC10907343 DOI: 10.1038/s41467-024-45784-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Accepted: 02/01/2024] [Indexed: 03/03/2024] Open
Abstract
Inhibition of Notch signalling with a gamma-secretase inhibitor (GSI) induces mammalian hair cell regeneration and partial hearing restoration. In this proof-of-concept Phase I/IIa multiple-ascending dose open-label trial (ISRCTN59733689), adults with mild-moderate sensorineural hearing loss received 3 intratympanic injections of GSI LY3056480, in 1 ear over 2 weeks. Phase I primary outcome was safety and tolerability. Phase lla primary outcome was change from baseline to 12 weeks in average pure-tone air conduction threshold across 2,4,8 kHz. Secondary outcomes included this outcome at 6 weeks and change from baseline to 6 and 12 weeks in pure-tone thresholds at individual frequencies, speech reception thresholds (SRTs), Distortion Product Otoacoustic Emissions (DPOAE) amplitudes, Signal to Noise Ratios (SNRs) and distribution of categories normal, present-abnormal, absent and Hearing Handicap Inventory for Adults/Elderly (HHIA/E). In Phase I (N = 15, 1 site) there were no severe nor serious adverse events. In Phase IIa (N = 44, 3 sites) the average pure-tone threshold across 2,4,8 kHz did not change from baseline to 6 and 12 weeks (estimated change -0.87 dB; 95% CI -2.37 to 0.63; P = 0.252 and -0.46 dB; 95% CI -1.94 to 1.03; P = 0.545, respectively), nor did the means of secondary measures. DPOAE amplitudes, SNRs and distribution of categories did not change from baseline to 6 and 12 weeks, nor did SRTs and HHIA/E scores. Intratympanic delivery of LY3056480 is safe and well-tolerated; the trial's primary endpoint was not met.
Collapse
|
7
|
Solis-Angeles S, Del Razo LM, Aguilar-Madrid G, Jiménez-Ramírez C, Coco L, Cabello-López A, Juárez-Pérez CA. Occupational Lead Exposure Ototoxicity Evaluated With Distortion-Product Otoacoustic Emissions. Ear Hear 2024; 45:329-336. [PMID: 37700446 DOI: 10.1097/aud.0000000000001431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/14/2023]
Abstract
OBJECTIVES To evaluate the extent of hearing loss among pottery workers in Mexico exposed to lead. DESIGN The authors conducted a cross-sectional study including 315 adult pottery workers. Auditory function was evaluated by air conduction pure-tone audiometry (pure-tone average) and distortion-product otoacoustic emission (DPOAE) levels (amplitude and signal-to-noise ratio). Lead exposure was assessed with a single blood sample test and classified as low, medium, and high according to blood lead tertiles. Logistic regression models were calculated for the association between blood lead levels, pure-tone average, and DPOAE records. RESULTS Median (25th-75th) blood lead levels were 14 μg/dL (7.5-22.6 μg/dL). The audiometric pattern and DPOAE records were similar across blood lead levels groups in all frequencies, and no statistically significant differences were found. Adjusted logistic regression models showed no increase in the odds for hearing thresholds >25 dB (HL) and DPOAE absence associated with blood lead levels, and no dose-response pattern was observed ( p > 0.05). CONCLUSIONS Given the results from this cross-sectional study, no association was found between blood lead levels and hearing loss assessed with DPOAE. Future longitudinal work should consider chronic lead exposure estimates among underrepresented populations, which can potentially inform safer work practices to minimize the risk of ototoxicity.
Collapse
|
8
|
Liu Y, Gong Q. Deep Learning Models for Predicting Hearing Thresholds Based on Swept-Tone Stimulus-Frequency Otoacoustic Emissions. Ear Hear 2024; 45:465-475. [PMID: 37990395 DOI: 10.1097/aud.0000000000001443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2023]
Abstract
OBJECTIVES This study aims to develop deep learning (DL) models for the quantitative prediction of hearing thresholds based on stimulus-frequency otoacoustic emissions (SFOAEs) evoked by swept tones. DESIGN A total of 174 ears with normal hearing and 388 ears with sensorineural hearing loss were studied. SFOAEs in the 0.3 to 4.3 kHz frequency range were recorded using linearly swept tones at a rate of 2 Hz/msec, with stimulus level changing from 40 to 60 dB SPL in 10 dB steps. Four DL models were used to predict hearing thresholds at octave frequencies from 0.5 to 4 kHz. The models-a conventional convolutional neural network (CNN), a hybrid CNN-k-nearest neighbor (KNN), a hybrid CNN-support vector machine (SVM), and a hybrid CNN-random forest (RF)-were individually built for each frequency. The input to the DL models was the measured raw SFOAE amplitude spectra and their corresponding signal to noise ratio spectra. All DL models shared a CNN-based feature self-extractor. They differed in that the conventional CNN utilized a fully connected layer to make the final regression decision, whereas the hybrid CNN-KNN, CNN-SVM, and CNN-RF models were designed by replacing the last fully connected layer of CNN model with a traditional machine learning (ML) regressor, that is, KNN, SVM, and RF, respectively. The model performance was evaluated using mean absolute error and SE averaged over 20 repetitions of 5 × 5 fold nested cross-validation. The performance of the proposed DL models was compared with two types of traditional ML models. RESULTS The proposed SFOAE-based DL models resulted in an optimal mean absolute error of 5.98, 5.22, 5.51, and 6.06 dB at 0.5, 1, 2, and 4 kHz, respectively, superior to that obtained by the traditional ML models. The produced SEs were 8.55, 7.27, 7.58, and 7.95 dB at 0.5, 1, 2, and 4 kHz, respectively. All the DL models outperformed any of the traditional ML models. CONCLUSIONS The proposed swept-tone SFOAE-based DL models were capable of quantitatively predicting hearing thresholds with satisfactory performance. With DL techniques, the underlying relationship between SFOAEs and hearing thresholds at disparate frequencies was explored and captured, potentially improving the diagnostic value of SFOAEs.
Collapse
|
9
|
Main M, Skoe E. Heightened OAEs in young adult musicians: Influence of current noise exposure and training recency. Hear Res 2024; 442:108925. [PMID: 38141520 PMCID: PMC10843712 DOI: 10.1016/j.heares.2023.108925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 11/26/2023] [Accepted: 12/03/2023] [Indexed: 12/25/2023]
Abstract
Otoacoustic emissions (OAEs) are a non-invasive metric of cochlear function. Studies of OAEs in musicians have yielded mixed results, ranging from evidence of diminished OAEs in musicians-suggesting noise-induced hearing loss-to no difference when compared to non-musicians, or even a trend for stronger OAEs in musicians. The goal of this study was to use a large sample of college students with normal hearing (n = 160) to compare OAE SNRs in musicians and non-musicians and to explore potential effects of training recency and noise exposure on OAEs in these cohorts. The musician cohort included both active musicians (who at the time of enrollment practiced at least weekly) and past musicians (who had at least 6 years of training). All participants completed a questionnaire about recent noise exposure (previous 12 months), and a subset of participants (71 musicians and 15 non-musicians) wore a personal noise dosimeter for one week to obtain a more nuanced and objective measure of exposure to assess how different exposure levels may affect OAEs before the emergence of a clinically significant hearing loss. OAEs were tested using both transient-evoked OAEs (TEOAEs) and distortion-product OAEs (DPOAEs). As predicted from the literature, musicians experienced significantly higher noise levels than non-musicians based on both subjective (self-reported) and objective measures. Yet we found stronger TEOAEs and DPOAEs in musicians compared to non-musicians in the ∼1-5 kHz range. Comparisons between past and active musicians suggest that enhanced cochlear function in young adult musicians does not require active, ongoing musical practice. Although there were no significant relations between OAEs and noise exposure as measured by dosimetry or questionnaire, active musicians had weaker DPOAEs than past musicians when the entire DPOAE frequency range was considered (up to ∼16 kHz), consistent with a subclinical noise-induced hearing loss that only becomes apparent when active musicians are contrasted with a cohort of individuals with comparable training but without the ongoing risks of noise exposure. Our findings suggest, therefore, that separate norms should be developed for musicians for earlier detection of incipient hearing loss. Potential explanations for enhanced cochlear function in musicians include pre-existing (inborn or demographic) differences, training-related enhancements of cochlear function (e.g., upregulation of prestin, stronger efferent feedback mechanisms), or a combination thereof. Further studies are needed to determine if OAE enhancements offer musicians protection against damage caused by noise exposure.
Collapse
|
10
|
Mo C, Ma TF, McPherson B. ABO blood group and cochlear function: evidence from a large sample size study. Int J Audiol 2024; 63:106-116. [PMID: 36576100 DOI: 10.1080/14992027.2022.2158379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Accepted: 12/05/2022] [Indexed: 12/29/2022]
Abstract
OBJECTIVE The present study investigated the effect of blood group on cochlear function in a large participant sample across different age groups. The study hypothesis was that participants with blood group O would show relatively reduced cochlear function as reflected in otoacoustic emission (OAE) measures. DESIGN Data were collected from transient evoked otoacoustic emission (TEOAE), distortion product otoacoustic emission (DPOAE), DPOAE input/output (I/O) function, and spontaneous otoacoustic emission (SOAE) recordings. STUDY SAMPLE Four hundred and sixty-three normal hearing adults aged 20-59 years among the four ABO blood groups participated in the study. RESULTS TEOAE and DPOAE amplitudes did not reveal significant differences for participants with blood group O compared with participants with non-O blood groups. No significant differences in I/O function categories were found among participants with different blood groups. SOAE prevalence was also not significantly different across blood groups. However, previously reported age and gender differences for OAE variables were confirmed. CONCLUSIONS Participants with blood group O were not found to have significantly reduced cochlear function, based on OAE measures. Results from the current study do not support the hypothesis that normal hearing individuals with different ABO blood groups differ in level of cochlear function.
Collapse
|
11
|
Simsek A, Aslan M. Evaluation of the auditory findings of patients with obstructive sleep apnea syndrome. Am J Otolaryngol 2024; 45:104027. [PMID: 37659225 DOI: 10.1016/j.amjoto.2023.104027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 08/10/2023] [Accepted: 08/17/2023] [Indexed: 09/04/2023]
Abstract
OBJECTIVES To investigate the effects of hypoxia occurring in patients with Obstructive Sleep Apnea Syndrome (OSAS) on Auditory evoked late latency, Auditory brainstem response, and the contralateral suppression of otoacoustic emissions. MATERIALS AND METHODS 46 patients diagnosed with OSAS were divided into groups as moderate and severe based on their Apnea Hipopnea Index (AHI) values. The control group consisted of 22 healthy individuals. All participants underwent an Auditory Brainstem Response (ABR) test, Auditory Evoked Late Latency Response (LLR), and Contralateral Suppression Otoacoustic Emission (CS-OAE). FINDINGS There was no statistical difference between the OSAS group and the control group regarding P1 latency, N1 latency, and P1 and N1 wave amplitude (p > 0.05). In ABR, statistically significant differences were found between the control, moderate OSAS, and severe OSAS groups in wave I in the right and left ear (p < 0.05). In the analyses performed for the otoacoustic emission frequencies with and without contralateral suppression of the right and left ear, suppression was not observed at some frequencies, and this was regarded as statistically significant (p < 0.05). CONCLUSION It is considered that OSAS does not have cortical effects but impacts the brainstem region and the cochlea. Bilateral impact, especially observed in wave I of ABR, is prominent on the auditory nerve. Considering that the medial olivo-cochlear (MOC) system is affected in patients with OSAS, it is thought that these patients are inadequate in suppressing noise, and this may cause various problems, particularly the inability to distinguish speech in noisy environments.
Collapse
|
12
|
Santarelli R, Scimemi P, Cama E, Domínguez-Ruiz M, Bonora C, Gallo C, Rodríguez-Ballesteros M, del Castillo I. Preservation of Distortion Product Otoacoustic Emissions in OTOF -Related Hearing Impairment. Ear Hear 2024; 45:250-256. [PMID: 37677959 PMCID: PMC10718209 DOI: 10.1097/aud.0000000000001421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Accepted: 07/16/2023] [Indexed: 09/09/2023]
Abstract
OBJECTIVES Attenuation of otoacoustic emissions over time has been reported for many patients with hearing impairment harboring mutations in the OTOF gene. In this study, the time course of changes of distortion product otoacoustic emissions (DPOAEs) has been analyzed in a cohort of patients in the light of tympanometry results. DESIGN The changes of DPOAEs in 16 patients with OTOF -related hearing impairment were retrospectively analyzed. RESULTS All but one subject showed DPOAEs bilaterally at the time of diagnosis. Three patients diagnosed as adults still had DPOAEs at ages of 27, 31, and 47 years, respectively. Follow-up was available for 7 children diagnosed at the age of 1 to 3 years, who still showed preservation of DPOAEs at ages of 5 to 16 years. The responses were absent or attenuated in amplitude at some follow-up appointments in association with type B or C tympanograms. CONCLUSIONS DPOAEs are preserved much longer than expected in a cohort of patients with OTOF -related hearing impairment. The previously reported loss of DPOAEs may have been caused in some children by increased middle ear impedance due to otitis media.
Collapse
|
13
|
王 子, 曹 麒, 胡 少, 范 新, 吕 俊, 王 会, 王 武, 李 华, 舒 易. [Study on gene therapy for DPOAE and ABR threshold changes in adult Otof-/- mice]. LIN CHUANG ER BI YAN HOU TOU JING WAI KE ZA ZHI = JOURNAL OF CLINICAL OTORHINOLARYNGOLOGY, HEAD, AND NECK SURGERY 2024; 38:49-56. [PMID: 38297849 PMCID: PMC11116155 DOI: 10.13201/j.issn.2096-7993.2024.01.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Indexed: 02/02/2024]
Abstract
Objective:This study aims to analyze the threshold changes in distortion product otoacoustic emissions(DPOAE) and auditory brainstem response(ABR) in adult Otof-/- mice before and after gene therapy, evaluating its effectiveness and exploring methods for assessing hearing recovery post-treatment. Methods:At the age of 4 weeks, adult Otof-/- mice received an inner ear injection of a therapeutic agent containing intein-mediated recombination of the OTOF gene, delivered via dual AAV vectors through the round window membrane(RWM). Immunofluorescence staining assessed the proportion of inner ear hair cells with restored otoferlin expression and the number of synapses.Statistical analysis was performed to compare the DPOAE and ABR thresholds before and after the treatment. Results:AAV-PHP. eB demonstrates high transduction efficiency in inner ear hair cells. The therapeutic regimen corrected hearing loss in adult Otof-/- mice without impacting auditory function in wild-type mice. The changes in DPOAE and ABR thresholds after gene therapy are significantly correlated at 16 kHz. Post-treatment,a slight increase in DPOAE was observeds,followed by a recovery trend at 2 months post-treatment. Conclusion:Gene therapy significantly restored hearing in adult Otof-/- mice, though the surgical delivery may cause transient hearing damage. Precise and gentle surgical techniques are essential to maximize gene therapy's efficacy.
Collapse
|
14
|
Cianfrone F, Cantore I, Cazzaniga C, Tauro F, Chiarelli R, Bianco F, Di Carmine F, Cantiani A, Colella MG, Ruscito P. Covid-19 infection in pregnant women: Auditory evaluation in infants. J Neonatal Perinatal Med 2024; 17:241-246. [PMID: 38701165 DOI: 10.3233/npm-230179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2024]
Abstract
Recent studies showed that COVID-19 infection can affect cochleo-vestibular system. The possibility of a vertical transmission is controversial. Some studies suggested that it is possible but unlikely, others find no evidence of vertical transmission. The objective of this study was to investigate whether exposure to COVID-19 during pregnancy or at birth has an impact on the hearing of the offspring. As part of the national hearing screening program, we performed in all newborns between January 2022 and February 2023, TEOAEs (Transient Evoked Otoacoustic Emissions) at birth and at 3 months. For those "REFER" at the third month test, we performed aABR (Automatic Auditory Brainstem Response) at 6 months. We analysed separately result between infants born to COVID-positive mothers during pregnancy and those born to COVID-negative mothers. To statistical verify differences we performed "Chi-square test". We enrolled a total of 157 infants, of whom 16 were born to mothers who had a molecular PCR test positive for COVID-19. In the latter we tested a total of 32 ears and only 1 ear (3,1%) resulted "REFER". On the other hand, in the control group we tested a total of 282 ears and 22 (7,8%) were found to be "REFER". Our study showed no significant differences in audiological assessment between newborns exposed to COVID-19 infection during pregnancy or at birth compared to the unexposed group. However, further studies with a larger patient's sample will be necessary for a more comprehensive evaluation.
Collapse
|
15
|
Lapsley Miller JA, Reed CM, Marshall L, Perez ZD, Villabona T. A Clinically Viable Medial Olivocochlear Reflex Assay Using Transient-Evoked Otoacoustic Emissions. Ear Hear 2024; 45:115-129. [PMID: 37475147 DOI: 10.1097/aud.0000000000001406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/22/2023]
Abstract
OBJECTIVES The contralateral medial olivocochlear reflex (MOCR) strength may indicate various auditory conditions in humans, but a clinically viable assay and equipment are needed for quick, accurate, and reliable measurements. The first experiment compared an earlier version of the assay, which used a nonlinear-mode chirp stimulus, with a new assay using a linear-mode click stimulus, designed to give reliable MOCR measurements in most normal-hearing ears. The second experiment extended the improved assay on a purpose-built binaural hardware platform that used forward-pressure level (FPL) calibration for both the stimulus and the contralateral MOCR elicitor. DESIGN Transient-evoked otoacoustic emission (TEOAE) tests were measured with and without a 60-dB SPL MOCR-evoking contralateral broadband noise. The normalized MOCR strength (MOCR%) was derived from the TEOAE responses for each trial pair using the complex pressure difference weighted by the TEOAE magnitude. Experiment 1 compared MOCR% within-subject and across-day using two TEOAE stimuli: nonlinear-mode chirps (50 dB SPL, bandpass 1-5 kHz, 14 ms window delayed by 2 ms) and linear-mode clicks (50 dB SPL, bandpass 0.5-2.5 kHz, 13 ms window delayed by 5 ms). TEOAE responses were analyzed in the 0.5 to 2.5 kHz band. Thirty adult participants with normal hearing (30 ears) completed the study. The TEOAE stimulus was calibrated in situ using spectral flattening, and the contralateral noise was calibrated in a coupler. Twelve TEOAE trial pairs were collected for each participant and condition. Experiment 2 used a purpose-built binaural system. The TEOAE stimuli were linear-mode clicks (50 dB SPL, bandpass 1-3 kHz, 13 ms window delayed by 5 ms), analyzed in the 1 to 3 kHz band over ~12 trial pairs. After a probe refit, an additional trial pair was collected for the two early-stopping signal-to-noise ratio criteria (15 and 20 dB). They were evaluated for single-trial reliability and test time. Nineteen adult participants with normal hearing (38 ears) completed the study. The TEOAE clicks and contralateral elicitor noise were calibrated in situ using FPL and delivered with automated timing. RESULTS MOCR% for linear-mode clicks was distinguishable from measurement variability in 98% to 100% of participants' ears (both experiments), compared with only 73% for the nonlinear-mode chirp (experiment 1). MOCR detectability was assessed using the MOCR% across-subject/within-subject variance ratio. The ratio in experiment 1 for linear-mode clicks was higher (8.0) than for nonlinear-mode chirps (6.4). The ratio for linear-mode clicks (8.9) in experiment 2 was slightly higher than for the comparable linear-mode stimulus (8.0) in experiment 1. TEOAEs showed excellent reliability with high signal-to-noise ratios in both experiments, but reliability was higher for linear-mode clicks than nonlinear-mode chirps. MOCR reliability for the two stimuli was comparable. The FPL pressure response retest reliability derived from the SPL at the microphone was higher than the SPL retest reliability across 0.4 to 8 kHz. Stable results required 2 to 3 trial pairs for the linear-mode click (experiments 1 and 2) and three for the nonlinear-mode chirp (experiment 1), taking around 2 min on average. CONCLUSIONS The linear-mode click assay produced measurable, reliable, and stable TEOAE and MOCR results on both hardware platforms in around 2 min per ear. The stimulus design and response window ensured that any stimulus artifact in linear mode was unlikely to confound the results. The refined assay is ready to produce high-quality data quickly for clinical and field studies to develop population norms, recognize diagnostic patterns, and determine risk profiles.
Collapse
|
16
|
Li Y, Yang X, Wang C, Cheng X, Qi B, En H, Wen C, Yu Y, Deng L, Liu D, Fu X, Liu H, Huang L. Analysis of audiological outcomes of children referred from a universal newborn hearing screening program over 9 years in Beijing, China. Sci Rep 2023; 13:22630. [PMID: 38114581 PMCID: PMC10730824 DOI: 10.1038/s41598-023-50171-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 12/15/2023] [Indexed: 12/21/2023] Open
Abstract
Universal newborn hearing screening (UNHS) and audiological diagnosis are crucial for children with congenital hearing loss (HL). The objective of this study was to analyze hearing screening techniques, audiological outcomes and risk factors among children referred from a UNHS program in Beijing. A retrospective analysis was performed in children who were referred to our hospital after failing UNHS during a 9-year period. A series of audiological diagnostic tests were administered to each case, to confirm and determine the type and degree of HL. Risk factors for HL were collected. Of 1839 cases, 53.0% were referred after only transient evoked otoacoustic emission (TEOAE) testing, 46.1% were screened by a combination of TEOAE and automatic auditory brainstem response (AABR) testing, and 1.0% were referred after only AABR testing. HL was confirmed in 55.7% of cases. Ears with screening results that led to referral experienced a more severe degree of HL than those with results that passed. Risk factors for HL were identified in 113 (6.1%) cases. The main risk factors included craniofacial anomalies (2.7%), length of stay in the neonatal intensive care unit longer than 5 days (2.4%) and birth weight less than 1500 g (0.8%). The statistical data showed that age (P < 0.001) and risk factors, including craniofacial anomalies (P < 0.001) and low birth weight (P = 0.048), were associated with the presence of HL. This study suggested that hearing screening plays an important role in the early detection of HL and that children with risk factors should be closely monitored.
Collapse
|
17
|
AlMakadma HA, Reed BF, Sanford CA. An Absorbance Peak Template for Clinical Assessment of Sound Conduction in Newborn Ears. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2023; 66:5152-5168. [PMID: 37971558 DOI: 10.1044/2023_jslhr-23-00122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Abstract
PURPOSE Power absorbance measures recorded over a wide range of frequencies allow for clinical inferences about the outer/middle ears' acoustic mechanics. A frequency-dependent feature in the newborn wideband absorbance response, the prominent mid-frequency absorbance peak, has been linked to middle-ear resonance. However, current normative methods were not designed to assess subtle changes in such features. This work aims to develop and validate an absorbance peak template (APT) for assessment of absorbance peaks in newborns. Additional objectives are to compare test performance of absorbance peaks and APTs to existing normative methods, to demonstrate APT-based methods for categorization of abnormal absorbance peaks, and to describe absorbance peak test-retest variability. METHOD Peak absorbance and peak frequency were analyzed in a training data set (490 measurements in 84 newborn ears who passed transient evoked otoacoustic emissions [TEOAEs] screenings), and an APT was developed by computing normal limits on these two absorbance peak variables. Split-set analysis evaluated the reproducibility of APT, and test-retest analysis was performed. Test performance analysis, conveyed by area under the receiver operating characteristic curve (AROC) and 95% confidence intervals (CIs), compared absorbance peak variables to absorbance area indices (AAIs) in a validation data set (359 ears that passed distortion-product OAE [DPOAE] screening and 64 ears that failed). APT-based assessment paradigms for normal and abnormal ears were compared to the common absorbance normative range paradigm. RESULTS Split-set analysis demonstrated a good reproducibility of APT, and test-retest of absorbance peak variables showed that they were stable measures for clinical assessment. Test performance of peak absorbance (AROC = 0.83; 95% CI [0.77, 0.88]) was comparable to the top-performing AAI variables (AROC = 0.85; 95% CI [0.80, 0.90]). APT-based assessment categorized measurements based on their peak absorbance and peak frequency and enhanced the detection of subtle frequency changes that were missed by the normative range method. CONCLUSION Analysis of absorbance peaks guided by APT has the potential to simplify and improve assessments of sound conduction pathways in newborn ears and can be used together with or in-place of current methods for analysis of wideband absorbance data.
Collapse
|
18
|
De Poortere N, Verhulst S, Degeest S, Keshishzadeh S, Dhooge I, Keppler H. Evaluation of Lifetime Noise Exposure History Reporting. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2023; 66:5129-5151. [PMID: 37988687 DOI: 10.1044/2023_jslhr-23-00266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2023]
Abstract
PURPOSE The purpose of this study is to critically evaluate lifetime noise exposure history (LNEH) reporting. First, two different approaches to evaluate the cumulative LNEH were compared. Second, individual LNEH was associated with the subjects' hearing status. Third, loudness estimates of exposure activities, by means of Jokitulppo- and Ferguson-based exposure levels, were compared with dosimeter sound-level measurements. METHOD One hundred one young adults completed the questionnaires, and a subgroup of 30 subjects underwent audiological assessment. Pure-tone audiometry, speech-in-noise intelligibility, distortion product otoacoustic emissions, auditory brainstem responses, and envelope following responses were included. Fifteen out of the 30 subjects took part in a noisy activity while wearing a dosimeter. RESULTS First, results demonstrate that the structured questionnaire yielded a greater amount of information pertaining to the diverse activities, surpassing the insights obtained from an open-ended questionnaire. Second, no significant correlations between audiological assessment and LNEH were found. Lastly, the results indicate that Ferguson-based exposure levels offer a more precise estimation of the actual exposure levels, in contrast to Jokitulppo-based estimates. CONCLUSIONS We propose several recommendations for determining the LNEH. First, it is vital to define accurate loudness categories and corresponding allocated levels, with a preference for the loudness levels proposed by Ferguson et al. (2019), as identified in this study. Second, a structured questionnaire regarding LNEH is recommended, discouraging open-ended questioning. Third, it is essential to include a separate category exclusively addressing work-related activities, encompassing various activities for more accurate surveying.
Collapse
|
19
|
Gafoor SA, Uppunda AK. Speech Perception in Noise and Medial Olivocochlear Reflex: Effects of Age, Speech Stimulus, and Response-Related Variables. J Assoc Res Otolaryngol 2023; 24:619-631. [PMID: 38079021 PMCID: PMC10752852 DOI: 10.1007/s10162-023-00919-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Accepted: 11/20/2023] [Indexed: 12/29/2023] Open
Abstract
PURPOSE The role of the medial olivocochlear system in speech perception in noise has been debated over the years, with studies showing mixed results. One possible reason for this could be the dependence of this relationship on the parameters used in assessing the speech perception ability (age, stimulus, and response-related variables). METHODS The current study assessed the influence of the type of speech stimuli (monosyllables, words, and sentences), the signal-to-noise ratio (+5, 0, -5, and -10 dB), the metric used to quantify the speech perception ability (percent-correct, SNR-50, and slope of the psychometric function) and age (young vs old) on the relationship between medial olivocochlear reflex (quantified by contralateral inhibition of transient evoked otoacoustic emissions) and speech perception in noise. RESULTS A linear mixed-effects model revealed no significant contributions of the medial olivocochlear reflex to speech perception in noise. CONCLUSION The results suggest that there was no evidence of any modulatory influence of the indirectly measured medial olivocochlear reflex strength on speech perception in noise.
Collapse
|
20
|
Wan H, Wang W, Liu J, Zhang Y, Yang B, Hua R, Chen H, Chen S, Hua Q. Cochlear metabolomics, highlighting novel insights of purine metabolic alterations in age-related hearing loss. Hear Res 2023; 440:108913. [PMID: 37939412 DOI: 10.1016/j.heares.2023.108913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 09/29/2023] [Accepted: 11/02/2023] [Indexed: 11/10/2023]
Abstract
Aging is an inevitable phase in mammals that leads to health impairments, including hearing loss. Age-related hearing loss (AHL) leads to psychosocial problems and cognitive decline in the elderly. In this study, mean thresholds of auditory brainstem responses (ABR) and distortion-product otoacoustic emissions (DPOAE) increased at multiple frequencies in aged rats (14 months old) compared to young rats (2 months old). Using untargeted ultra-high performance liquid chromatography-mass spectroscopy (LC-MS), we quantified molecular metabolic markers in the cochlea of aged rats with hearing loss. A total of 137 different metabolites were identified in two groups, highlighting several prominent metabolic pathways related to purine metabolism; glycine, serine, and threonine metabolism; arginine and proline metabolism; and pyrimidine metabolism. In addition, the beneficial effects of purine supplementation were demonstrated in a mimetic model of senescent marginal cells (MCs). Overall, altered metabolic profiling is both the cause and manifestation of pathology, and our results suggest that cellular senescence and dysfunctional cochlear metabolism may contribute to the progression of AHL. These findings are seminal in elucidating the pathophysiological mechanisms underlying AHL and serve as a basis for future clinical predictions and interventions in AHL.
Collapse
|
21
|
King CD, Lovich SN, Murphy DL, Landrum R, Kaylie D, Shera CA, Groh JM. Individual similarities and differences in eye-movement-related eardrum oscillations (EMREOs). Hear Res 2023; 440:108899. [PMID: 37979436 PMCID: PMC11081086 DOI: 10.1016/j.heares.2023.108899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 10/18/2023] [Accepted: 10/23/2023] [Indexed: 11/20/2023]
Abstract
We recently discovered a unique type of otoacoustic emission (OAE) time-locked to the onset (and offset) of saccadic eye movements and occurring in the absence of external sound (Gruters et al., 2018). How and why these eye-movement-related eardrum oscillations (EMREOs) are generated is unknown, with a role in visual-auditory integration being the likeliest candidate. Clues to both the drivers of EMREOs and their purpose can be gleaned by examining responses in normal hearing human subjects. Do EMREOs occur in all individuals with normal hearing? If so, what components of the response occur most consistently? Understanding which attributes of EMREOs are similar across participants and which show more variability will provide the groundwork for future comparisons with individuals with hearing abnormalities affecting the ear's various motor components. Here we report that in subjects with normal hearing thresholds and normal middle ear function, all ears show (a) measurable EMREOs (mean: 58.7 dB SPL; range 45-67 dB SPL for large contralateral saccades), (b) a phase reversal for contra- versus ipsilaterally-directed saccades, (c) a large peak in the signal occurring soon after saccade onset, (d) an additional large peak time-locked to saccade offset and (e) evidence that saccade duration is encoded in the signal. We interpret the attributes of EMREOs that are most consistent across subjects as the ones that are most likely to play an essential role in their function. The individual differences likely reflect normal variation in individuals' auditory system anatomy and physiology, much like traditional measures of auditory function such as auditory-evoked OAEs, tympanometry and auditory-evoked potentials. Future work will compare subjects with different types of auditory dysfunction to population data from normal hearing subjects. Overall, these findings provide important context for the widespread observations of visual- and eye-movement related signals found in cortical and subcortical auditory areas of the brain.
Collapse
|
22
|
Caglar Yagci H, Ozdamar OI, Ertugrul O, Salman CT, Yagci I. Hearing Loss and the Affecting Factors in Patients with Fibromyalgia. J Coll Physicians Surg Pak 2023; 33:1124-1129. [PMID: 37804017 DOI: 10.29271/jcpsp.2023.10.1124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 09/11/2023] [Indexed: 10/08/2023]
Abstract
OBJECTIVE To find the frequency of hearing loss in newly diagnosed patients with fibromyalgia (FM), and the factors affecting it. STUDY DESIGN Descriptive study. Place and Duration of the Study: Department of Physical Medicine and Rehabilitation and Department of Otorhinolaryngology Head and Neck Surgery, Istanbul Medeniyet University, Goztepe Prof. Dr. Suleyman Yalcin City Hospital, Turkey, from March 2021 to November 2022. METHODOLOGY Patients with FM and gender/age matched controls were compared with pure-tone audiometric (PTA), and transient evoked otoacoustic emissions (TEOE) tests after standardised otorhinolaryngologic assessment The subjects were questioned for NSAID uptake and scored with ASAS-NSAID score. RESULTS There were 33 patients with FM and 32 healthy volunteers. Subjective tinnitus, dizziness, and hearing loss rate in the FM group were 12%, 18%, and 15%, respectively. PTA air and bone conduction studies yielded significant differences between the control and FM group (p<0.05). The statistical difference was pronounced in higher frequencies. TEOE tests showed the FM group had significantly lower scores when compared to the control group at 3000 Hz and 4000 Hz (p<0.05). The median ASAS-NSAID scores were 0 for the control group and 7.78 for the FM group (p <0.001). CONCLUSION Patients with FM had high rate of audiometric hearing loss of the sensorineural type. The abnormalities were more prominent in the high frequencies but also present in the low frequencies. KEY WORDS Fibromyalgia syndrome, Hearing loss, Audiometry, Ototoxicity, Central sensitisation.
Collapse
|
23
|
Sakaki Y, Hosoya M, Nishiyama T, Wakabayashi T, Shimanuki MN, Ozawa H, Oishi N. A Case of Vestibular Schwannoma with Deafness Showing Remarkable Hearing Recovery Following Hearing-Preserving Surgery. J Int Adv Otol 2023; 19:426-430. [PMID: 37789631 PMCID: PMC10645190 DOI: 10.5152/iao.2023.221035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Accepted: 05/01/2023] [Indexed: 10/05/2023] Open
Abstract
Surgery for vestibular schwannoma can be divided into hearing-preserving and nonhearing-preserving surgeries. Hearing-preserving surgery is usually not considered in patients with deafness due to vestibular schwannoma, because hearing is unlikely to improve, and surgery aims to maximize the tumor resection at the expense of hearing. We report an extremely rare case of a 46-year-old man with unilateral profound hearing loss due to a vestibular schwannoma with marked cystic degeneration in the left cistern, which significantly recovered to near-normal hearing levels after hearing-preserving surgery. Hearing loss gradually worsened, and preoperative pure-tone evaluation showed complete hearing loss in the left ear. However, the response to the distortion product otoacoustic emission was preserved, and hearing loss was considered to be retrocochlear. Tumor resection was performed using the retrolabyrinthine approach with continuous monitoring using dorsal cochlear nucleus action potential, auditory brainstem response, and facial nerve function muscle action potential. The cistern portion of the tumor was almost completely resected along with the wall. Postoperatively, the pure-tone threshold on the left side markedly improved. The present case clearly demonstrates the possibility of hearing recovery in patients with retrocochlear hearing loss. We should consider expanding the indications for hearing-preserving surgery.
Collapse
|
24
|
Srivastava I, Kalaiah MK, Roushan R, Shastri U, Kumar K. The effect of coffee on contralateral suppression of transient evoked otoacoustic emissions. F1000Res 2023; 11:878. [PMID: 37841827 PMCID: PMC10568215 DOI: 10.12688/f1000research.122851.2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/04/2023] [Indexed: 10/17/2023] Open
Abstract
Background: Coffee is a popular non-alcoholic beverage consumed by humans across the world. It contains caffeine, which is a type of stimulant of the central nervous system. In the auditory system, it has a positive effect on auditory brainstem response and perception of speech in noise. Further, caffeine has an inhibitory effect in the cochlea, but studies have rarely investigated its effect on otoacoustic emissions (OAEs) in humans. OAEs are low-intensity sounds produced by the cochlea, which could be recorded in the ear canal. The present study was carried out to investigate the effect of coffee on transient evoked otoacoustic emission (TEOAE) and contralateral suppression of TEOAE. Method: A total of 52 young adults participated in the study. A cross-over study design was used for the present investigation. The TEOAE and contralateral suppression of TEOAE were recorded before and after consumption of coffee and milk. The contralateral suppression of TEOAE was measured by presenting white noise to the contralateral ear at 40, 50, and 60 dB sound pressure level (SPL). Results: The mean amplitude of TEOAE before and after consumption of coffee was similar in both ears. Further, the mean contralateral suppression of TEOAE was slightly larger after consumption of coffee in both ears. However, the mean difference was not significant in both the ears. Conclusions: Based on the findings of present study, coffee has no significant effect on the amplitude of TEOAE and contralateral suppression of TEOAE.
Collapse
|
25
|
Pyarali M, Akhtar S, Adeel M, Mallick SA, Uneeb SN, Aslam A. Neonatal Hearing Screening Programme And Challenges Faced By The Developing Country: A Tertiary Care Hospital Experience. J PAK MED ASSOC 2023; 73:1788-1793. [PMID: 37817685 DOI: 10.47391/jpma.6264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/12/2023]
Abstract
OBJECTIVE To screen new-borns to diagnose any hearing impairment early. METHODS The prospective, cross-sectionalstudy was conducted at the Department of Otorhinolaryngology, Head and Neck Surgery Liaquat National Hospital, Karachi, from November 1, 2020, to April 30, 2021, and new- borns of either gender aged >12h born via spontaneous vaginal delivery, induced labour, and Caesarean section. A predesigned questionnaire was used to collect detailed case history, including gestational age, duration of labour, and other prenatal, natal, and postnatal risk factors. Otoacoustic emission test was performed, and infants referred twice were scheduled for complete diagnostic evaluation and brainstem evoked response audiometry. Data was analysed using SPSS 23. RESULTS Of the 267 neonates, 249(93.3%) passed the first screening. Of the remaining 18(6.7%) neonates, 8(44.4%) passed the second screening, while 10(55.5%) were asked to come for a follow-up after three weeks. Of them, 3(30%) returned for check-up, while 7(70%) did not show up. CONCLUSIONS Neonatal risk factors associated with hearing loss need to be identified, and a comprehensive hearing screening programme is required for neonates.
Collapse
|