101
|
Ninomiya T, Nogami N, Kozuki T, Harada D, Kubo T, Ohashi K, Kuyama S, Kudo K, Bessho A, Fujimoto N, Aoe K, Shibayama T, Minami D, Sugimoto K, Ochi N, Takigawa N, Hotta K, Kiura K. Updated analysis of a phase I trial of afatinib (Afa) and bevacizumab (Bev) in chemo-naïve patients (pts) with advanced non-small cell lung cancer (NSCLC) harboring EGFR-mutations: OLCSG1404. Ann Oncol 2019. [DOI: 10.1093/annonc/mdz260.047] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
102
|
Morita R, Abo D, Sakuhara Y, Soyama T, Katoh N, Miyamoto N, Uchinami Y, Shimizu S, Shirato H, Kudo K. Percutaneous insertion of hepatic fiducial true-spherical markers for real-time adaptive radiotherapy. MINIM INVASIV THER 2019; 29:334-343. [DOI: 10.1080/13645706.2019.1663217] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
103
|
Miyata M, Kakeda S, Kudo K, Iwata S, Tanaka Y, Wang Y, Korogi Y. Evaluation of oxygen extraction fraction in systemic lupus erythematosus patients using quantitative susceptibility mapping. J Cereb Blood Flow Metab 2019; 39:1648-1658. [PMID: 29547080 PMCID: PMC6681530 DOI: 10.1177/0271678x18764829] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The purposes of this study are to assess the oxygen extraction fraction (OEF) changes on MRI-based quantitative susceptibility mapping (QSM) in systemic lupus erythematosus (SLE) patients and to determine whether QSM-OEF is associated with disease activity in SLE. We enrolled 42 SLE patients and 20 healthy subjects (HS) who had no pathologies on conventional brain MRI. Disease activity was assessed using SLE Disease Activity Index (SLEDAI). For the measurement of QSM-OEF, QSM data were analysed using the Perfusion Mismatch Analyzer software program. Spearman's or Pearson's correlation coefficients were calculated, and independent predictors were identified through a multiple linear regression analysis. QSM-OEF was significantly higher in SLE than that in HS (51.3 ± 10.1 vs. 40.5 ± 3.7, p < 0.001). QSM-OEF was positively correlated with SLEDAI and the presence of neuropsychiatric symptom (NPS) scores (ρ = 0.663, p < 0.001 and ρ = 0.340, p = 0.028). At multiple linear regression analysis, SLEDAI and NPS were independently associated with QSM-OEF (standardized β = 0.426, p = 0.016 and standardized β = 6.148, p = 0.029). In the SLE patients, QSM-OEF is associated with disease activity, which might predict an increased risk of stroke in SLE.
Collapse
|
104
|
Fujima N, Shimizu Y, Yoshida D, Kano S, Mizumachi T, Homma A, Yasuda K, Onimaru R, Sakai O, Kudo K, Shirato H. Machine-Learning-Based Prediction of Treatment Outcomes Using MR Imaging-Derived Quantitative Tumor Information in Patients with Sinonasal Squamous Cell Carcinomas: A Preliminary Study. Cancers (Basel) 2019; 11:cancers11060800. [PMID: 31185611 PMCID: PMC6627127 DOI: 10.3390/cancers11060800] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Revised: 06/02/2019] [Accepted: 06/06/2019] [Indexed: 02/06/2023] Open
Abstract
The purpose of this study was to determine the predictive power for treatment outcome of a machine-learning algorithm combining magnetic resonance imaging (MRI)-derived data in patients with sinonasal squamous cell carcinomas (SCCs). Thirty-six primary lesions in 36 patients were evaluated. Quantitative morphological parameters and intratumoral characteristics from T2-weighted images, tumor perfusion parameters from arterial spin labeling (ASL) and tumor diffusion parameters of five diffusion models from multi-b-value diffusion-weighted imaging (DWI) were obtained. Machine learning by a non-linear support vector machine (SVM) was used to construct the best diagnostic algorithm for the prediction of local control and failure. The diagnostic accuracy was evaluated using a 9-fold cross-validation scheme, dividing patients into training and validation sets. Classification criteria for the division of local control and failure in nine training sets could be constructed with a mean sensitivity of 0.98, specificity of 0.91, positive predictive value (PPV) of 0.94, negative predictive value (NPV) of 0.97, and accuracy of 0.96. The nine validation data sets showed a mean sensitivity of 1.0, specificity of 0.82, PPV of 0.86, NPV of 1.0, and accuracy of 0.92. In conclusion, a machine-learning algorithm using various MR imaging-derived data can be helpful for the prediction of treatment outcomes in patients with sinonasal SCCs.
Collapse
|
105
|
Endo K, Takahata M, Sugimori H, Yamada S, Tadano S, Wang J, Todoh M, Ito YM, Takahashi D, Kudo K, Iwasaki N. Magnetic resonance imaging T1 and T2 mapping provide complementary information on the bone mineral density regarding cancellous bone strength in the femoral head of postmenopausal women with osteoarthritis. Clin Biomech (Bristol, Avon) 2019; 65:13-18. [PMID: 30928786 DOI: 10.1016/j.clinbiomech.2019.03.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Revised: 01/30/2019] [Accepted: 03/18/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND Since bone mass is not the only determinant of bone strength, there has been increasing interest in incorporating the bone quality into fracture risk assessments. We aimed to examine whether the magnetic resonance imaging (MRI) T1 or T2 mapping value could provide information that is complementary to bone mineral density for more accurate prediction of cancellous bone strength. METHODS Four postmenopausal women with hip osteoarthritis underwent 3.0-T MRI to acquire the T1 and T2 values of the cancellous bone of the femoral head before total hip arthroplasty. After the surgery, the excised femoral head was portioned into multiple cubic cancellous bone specimens with side of 5 mm, and the specimens were then subjected to microcomputed tomography followed by biomechanical testing. FINDINGS The T1 value positively correlated with the yield stress (σy) and collapsed stress (σc). The T2 value did not correlate with the yield stress, but it correlated with the collapsed stress and strength reduction ratio (σc/σy), which reflects the progressive re-fracture risk. Partial correlation coefficient analyses, after adjusting for the bone mineral density, showed a statistically significant correlation between T1 value and yield stress. The use of multiple coefficients of determination by least squares analysis emphasizes the superiority of combining the bone mineral density and the MRI mapping values in predicting the cancellous bone strength compared with the bone mineral density-based prediction alone. INTERPRETATION The MRI T1 and T2 values predict cancellous bone strength including the change in bone quality.
Collapse
|
106
|
Aoike S, Sugimori H, Fujima N, Suzuki Y, Shimizu Y, Suwa A, Ishizaka K, Kudo K. Three-dimensional Pseudo-continuous Arterial Spin-labeling Using Turbo-spin Echo with Pseudo-steady State Readout: A Comparison with Other Major Readout Methods. Magn Reson Med Sci 2019; 18:170-177. [PMID: 30318501 PMCID: PMC6460127 DOI: 10.2463/mrms.tn.2018-0031] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
We evaluated 3D pseudo-continuous arterial spin labeling (pCASL) using turbo spin echo with a pseudo-steady-state (PSS) readout in comparison with the other major readout methods of 3D spiral and 2D echo-planar imaging (EPI). 3D-PSS produced cerebral blood flow (CBF) values well correlated to those of the 3D spiral readout. By visual evaluation, the image quality of 3D-PSS pCASL was superior to that of 2D-EPI. The 3D-PSS technique was suggested useful as pCASL readout.
Collapse
|
107
|
Kikuchi Y, Naya M, Oyama-Manabe N, Manabe O, Sugimori H, Kudo K, Kato F, Aikawa T, Tsutsui H, Tamaki N, Shirato H. Assessment of Coronary Flow Velocity Reserve in the Left Main Trunk Using Phase-contrast MR Imaging at 3T: Comparison with 15O-labeled Water Positron Emission Tomography. Magn Reson Med Sci 2019; 18:134-141. [PMID: 30047496 PMCID: PMC6460128 DOI: 10.2463/mrms.mp.2018-0003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose: The aim of this study was to verify coronary flow velocity reserve (CFVR) on the left main trunk (LMT) in comparison with myocardial flow reserve (MFR) by 15O-labeled water positron emission tomography (PET) (MFR-PET) in both the healthy adults and the patients with coronary artery disease (CAD), and to evaluate the feasibility of CFVR to detect CAD. Methods: Eighteen healthy adults and 13 patients with CAD were evaluated. CFVR in LMT was estimated by 3T magnetic resonance imaging (MRI) with phase contrast technique. MFR-PET in the LMT territory including anterior descending artery and circumflex artery was calculated as the ratio of myocardial blood flow (MBF)-PET at stress to MBF-PET at rest. Results: There was a significant positive relationship between CFVR and MFR-PET (R = 0.45, P < 0.0001). Inter-observer calculations of CFVR showed good correlation (R2 = 0.93, P < 0.0001). The CFVR in patients with CAD was significantly lower than that in healthy adults (1.90 ± 0.61 vs. 2.77 ± 1.03, respectively, P = 0.01), which were similar to the results of MFR-PET (2.23 ± 0.84 vs. 3.96 ± 1.04, respectively, P < 0.0001). For the detection of patients with CAD, the area under the curve was 0.78 (P = 0.01). The sensitivity was 0.77 and specificity was 0.72 when a cut-off of 2.15 was used. Conclusion: CFVR by 3T was validated with MFR-PET. CFVR could detect the patients with CAD. This method is a simple and reliable index without radiation or contrast material.
Collapse
|
108
|
Kato F, Kudo K, Yamashita H, Baba M, Shimizu A, Oyama-Manabe N, Kinoshita R, Li R, Shirato H. Predicting metastasis in clinically negative axillary lymph nodes with minimum apparent diffusion coefficient value in luminal A-like breast cancer. Breast Cancer 2019; 26:628-636. [PMID: 30937834 DOI: 10.1007/s12282-019-00969-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Accepted: 03/16/2019] [Indexed: 12/26/2022]
Abstract
BACKGROUND We investigated the usefulness of the minimum ADC value of primary breast lesions for predicting axillary lymph node (LN) status in luminal A-like breast cancers with clinically negative nodes in comparison with the mean ADC. METHODS Forty-four luminal A-like breast cancers without axillary LN metastasis at preoperative clinical evaluation, surgically resected with sentinel LN biopsy, were retrospectively studied. Mean and minimum ADC values of each lesion were measured and statistically compared between LN positive (n = 12) and LN negative (n = 32) groups. An ROC curve was drawn to determine the best cutoff value to differentiate LN status. Correlations between mean and minimum ADC values and the number of metastatic axillary LNs were investigated. RESULTS Mean and minimum ADC values of breast lesions with positive LN were significantly lower than those with negative LN (mean 839.9 ± 110.9 vs. 1022.2 ± 250.0 × 10- 6 mm2/s, p = 0.027, minimum 696.7 ± 128.0 vs. 925.0 ± 257.6 × 10- 6 mm2/s, p = 0.004). The sensitivity and NPV using the best cutoff value from ROC using both mean and minimum ADC were 100%. AUC of the minimum ADC (0.784) was higher than that of the mean ADC (0.719). Statistically significant negative correlations were observed between both mean and minimum ADCs and number of positive LNs, with stronger correlation to minimum ADC than mean ADC. CONCLUSIONS The minimum ADC value of primary breast lesions predicts axillary LN metastasis in luminal A-like breast cancer with clinically negative nodes, with high sensitivity and high NPV.
Collapse
|
109
|
Nakagawa D, Kudo K, Awe O, Zanaty M, Nagahama Y, Cushing C, Magnotta V, Hayakawa M, Allan L, Greenlee J, Awad IA, Carroll T, Torner J, Raghavan ML, Hasan DM. Detection of microbleeds associated with sentinel headache using MRI quantitative susceptibility mapping: pilot study. J Neurosurg 2019; 130:1391-1397. [PMID: 29799347 PMCID: PMC6773513 DOI: 10.3171/2018.2.jns1884] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2018] [Accepted: 02/16/2018] [Indexed: 11/06/2022]
Abstract
OBJECT Sentinel headaches (SHs) associated with cerebral aneurysms (CAs) could be due to microbleeds, which are considered a sign that an aneurysm is unstable. Despite the prognostic importance of these microbleeds, they remain difficult to detect using routine imaging studies. The objective of this pilot study is to detect microbleeds associated with SH using a magnetic resonance imaging (MRI) quantitative susceptibility mapping (QSM) sequence and then evaluate the morphological characteristics of unstable aneurysms with microbleeds. METHODS Twenty CAs in 16 consecutive patients with an initial presentation of headache (HA) leading to a diagnosis of CA were analyzed. Headaches in 4 of the patients (two of whom had 2 aneurysms each) met the typical definition of SH, and the other 12 patients (two of whom also had 2 aneurysms each) all had migraine HA. All patients underwent imaging with the MRI-QSM sequence. Two independent MRI experts who were blinded to the patients' clinical history performed 3D graphical analysis to evaluate for potential microbleeds associated with these CAs. Computational flow and morphometric analyses were also performed to estimate wall shear and morphological variables. RESULTS In the 4 patients with SH, MRI-QSM results were positive for 4 aneurysms, and hence these aneurysms were considered positive for non-heme ferric iron (microbleeds). The other 16 aneurysms were negative. Among aneurysm shape indices, the undulation index was significantly higher in the QSM-positive group than in the QSM-negative group. In addition, the spatial averaged wall shear magnitude was lower in the aneurysm wall in direct contact with microbleeds. CONCLUSIONS MRI-QSM allows for objective detection of microbleeds associated with SH and therefore identification of unstable CAs. CAs with slightly greater undulation indices are associated with positive MRI-QSM results and hence with microbleeds. Studies with larger populations are needed to confirm these preliminary findings.
Collapse
|
110
|
Fujima N, Homma A, Harada T, Shimizu Y, Tha KK, Kano S, Mizumachi T, Li R, Kudo K, Shirato H. The utility of MRI histogram and texture analysis for the prediction of histological diagnosis in head and neck malignancies. Cancer Imaging 2019; 19:5. [PMID: 30717792 PMCID: PMC6360729 DOI: 10.1186/s40644-019-0193-9] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Accepted: 01/30/2019] [Indexed: 01/21/2023] Open
Abstract
BACKGROUND To assess the utility of histogram and texture analysis of magnetic resonance (MR) fat-suppressed T2-weighted imaging (Fs-T2WI) for the prediction of histological diagnosis of head and neck squamous cell carcinoma (SCC) and malignant lymphoma (ML). METHODS The cases of 57 patients with SCC (45 well/moderately and 12 poorly differentiated SCC) and 10 patients with ML were retrospectively analyzed. Quantitative parameters with histogram features (relative mean signal, coefficient of variation, kurtosis and skewness) and gray-level co-occurrence matrix (GLCM) features (contrast, correlation, energy and homogeneity) were calculated using Fs-T2WI data with a manual tumor region of interest (ROI). RESULTS The following significantly different values were obtained for the total SCC versus ML groups: relative mean signal (3.65 ± 0.86 vs. 2.61 ± 0.49), contrast (72.9 ± 16.2 vs. 49.3 ± 8.7) and homogeneity (2.22 ± 0.25 × 10- 1 vs. 2.53 ± 0.12 × 10- 1). In the comparison of the SCC histological grades, the relative mean signal and contrast were significantly lower in the poorly differentiated SCC (2.89 ± 0.63, 56.2 ± 12.9) compared to the well/moderately SCC (3.85 ± 0.81, 77.5 ± 13.9). The homogeneity in poorly differentiated SCC (2.56 ± 0.15 × 10- 1) was higher than that of the well/moderately SCC (2.1 ± 0.18 × 10- 1). CONCLUSIONS Parameters obtained by histogram and texture analysis of Fs-T2WI may be useful for noninvasive prediction of histological type and grade in head and neck malignancy.
Collapse
|
111
|
Harada T, Kudo K. [A Diagnostic Imaging Approach for Tremor]. BRAIN AND NERVE = SHINKEI KENKYU NO SHINPO 2018; 70:1331-1340. [PMID: 30523213 DOI: 10.11477/mf.1416201191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Tremor is one of the common movement disorders encountered in a clinical practice. Tremor is often difficult to diagnose and can be easily mistaken for another disorder, hence diagnostic imaging is employed to provide objective information. The morphometry, signal changes, neuromelanin, and iron deposition can be evaluated by MRI, whereas cardiac sympathetic nerve and dopamine transporter degeneration are detected by means of nuclear medicine. The purpose of this article is to provide an overview of the role and indications of imaging test, as well as a review of the methods in which the findings of images are interpreted.
Collapse
|
112
|
Kimura K, Kudo K, Kurihara T, Yoshiya S, Mano Y, Takeishi K, Itoh S, Harada N, Ikegami T, Yoshizumi T, Ikeda T. Rendezvous Technique Using Double Balloon Endoscope for Removal of Multiple Intrahepatic Bile Duct Stones in Hepaticojejunostomy After Living Donor Liver Transplant: A Case Report. Transplant Proc 2018; 51:579-584. [PMID: 30879594 DOI: 10.1016/j.transproceed.2018.12.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Accepted: 12/09/2018] [Indexed: 02/08/2023]
Abstract
Cholangitis is a major complication following transplantation. We report a living donor liver transplant (LDLT) patient with cholangitis due to multiple stones in the intrahepatic bile duct during hepaticojejunostomy anastomosis, who was successfully treated with the rendezvous technique using double balloon endoscope. A 64-year-old woman underwent LDLT with right lobe graft and hepaticojejunostomy for Wilson disease. There was bile leakage with biliary peritonitis, which was treated conservatively after transplant. Two years after surgery, she developed reiterated cholangitis due to stenosis of hepaticojejunostomy anastomosis and multiple stones in the intrahepatic bile ducts. Percutaneous transhepatic biliary drainage was performed. The size of the drainage tube was increased, and the anastomotic area was dilated in a stepwise manner using a balloon catheter. The stones were crushed and lithotomy was performed using electronic hydraulic lithotripsy through cholangioscopy. Finally, lithotomy was performed for the remaining stones through endoscopic retrograde cholangiography with the rendezvous technique using the double balloon endoscope. Rendezvous approach with percutaneous transhepatic biliary drainage and double balloon endoscopic retrograde cholangiography was an effective treatment for the multiple intrahepatic stones in hepaticojejunostomy following LDLT with right lobe graft.
Collapse
|
113
|
Sakurai T, Kimura S, Kimata M, Nojiri H, Awaji S, Okubo S, Ohta H, Uwatoko Y, Kudo K, Koike Y. Development and application of 2.5 GPa-25 T high-pressure high-field electron spin resonance system using a cryogen-free superconducting magnet. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2018; 296:1-4. [PMID: 30165264 DOI: 10.1016/j.jmr.2018.08.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Revised: 08/20/2018] [Accepted: 08/21/2018] [Indexed: 06/08/2023]
Abstract
We have developed a high-pressure electron spin resonance probe and successfully installed into the world's highest-field cryogen-free superconducting magnet having a maximum central field of 24.6 T. The high pressure of 2.5 GPa is achieved by the specially designed piston-cylinder pressure cell using THz-wave-transparent components. In the first application of this high-pressure high-field ESR system, we observed that the orthogonal dimer spin system SrCu2(BO3)2 undergoes a quantum phase transition from the dimer singlet ground to the plaquette singlet ground states.
Collapse
|
114
|
Oyama-Manabe N, Yabusaki S, Manabe O, Kato F, Kanno-Okada H, Kudo K. IgG4-related Cardiovascular Disease from the Aorta to the Coronary Arteries: Multidetector CT and PET/CT. Radiographics 2018; 38:1934-1948. [DOI: 10.1148/rg.2018180049] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
115
|
Kubo T, Watanabe H, Ninomiya K, Kudo K, Minami D, Murakami E, Ochi N, Ninomiya T, Harada D, Yasugi M, Ichihara E, Ohashi K, Fujiwara K, Hotta K, Tabata M, Maeda Y, Kiura K. Immune checkpoint inhibitor efficacy and safety in elderly non-small cell lung cancer patients. Ann Oncol 2018. [DOI: 10.1093/annonc/mdy292.095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
116
|
Ota T, Takeda T, Fukui T, Nakahara Y, Kudo K, Okabe T, Hayashi H, Otani S, Hiyoshi Y, Yonesaka K, Sugiura T, Suzumura T, Terashima M, Nakano Y, Hasegawa Y, Tsukuda H, Matsui K, Masuda N, Fukuoka M. Serum biomarkers during the first cycle of anti-PD-1 antibody therapies in non-small cell lung cancer. Ann Oncol 2018. [DOI: 10.1093/annonc/mdy288.073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
117
|
Fujima N, Hirata K, Shiga T, Li R, Yasuda K, Onimaru R, Tsuchiya K, Kano S, Mizumachi T, Homma A, Kudo K, Shirato H. Integrating quantitative morphological and intratumoural textural characteristics in FDG-PET for the prediction of prognosis in pharynx squamous cell carcinoma patients. Clin Radiol 2018; 73:1059.e1-1059.e8. [PMID: 30245069 DOI: 10.1016/j.crad.2018.08.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2018] [Accepted: 08/24/2018] [Indexed: 12/15/2022]
Abstract
AIM To assess potential prognostic factors in pharynx squamous cell carcinoma (SCC) patients by quantitative morphological and intratumoural characteristics obtained by 2-[18F]-fluoro-2-deoxy-d-glucose positron-emission tomography/computed tomography (FDG-PET/CT). MATERIALS AND METHODS The cases of 54 patients with pharynx SCC who underwent chemoradiation therapy were analysed retrospectively. Using their FDG-PET data, the quantitative morphological and intratumoural characteristics of 14 parameters were calculated. The progression-free survival (PFS) and overall survival (OS) information was obtained from patient medical records. Univariate and multivariate analyses were performed to assess the 14 quantitative parameters as well as the T-stage, N-stage, and tumour location data for their relation to PFS and OS. When an independent predictor was suggested in the multivariate analysis, the parameter was further assessed using the Kaplan-Meier method. RESULTS In the assessment of PFS, the univariate and multivariate analyses indicated the following as independent predictors: the texture parameter of homogeneity and the morphological parameter of sphericity. In the Kaplan-Meier analysis, the PFS rate was significantly improved in the patients who had both a higher value of homogeneity (p=0.01) and a higher value of sphericity (p=0.002). With the combined use of homogeneity and sphericity, the patients with different PFS rates could be divided more clearly. CONCLUSION The quantitative parameters of homogeneity and sphericity obtained by FDG-PET can be useful for the prediction of the PFS of pharynx SCC patients, especially when used in combination.
Collapse
|
118
|
Fujima N, Hirata K, Shiga T, Yasuda K, Onimaru R, Tsuchiya K, Kano S, Mizumachi T, Homma A, Kudo K, Shirato H. Semi-quantitative analysis of pre-treatment morphological and intratumoral characteristics using 18F-fluorodeoxyglucose positron-emission tomography as predictors of treatment outcome in nasal and paranasal squamous cell carcinoma. Quant Imaging Med Surg 2018; 8:788-795. [PMID: 30306059 DOI: 10.21037/qims.2018.09.09] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Background To investigate the utility of quantitative morphological and intratumoral characteristics obtained by 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (FDG-PET/CT) for the prediction of treatment outcome in patients with nasal or paranasal cavity squamous cell carcinoma (SCC). Methods Twenty-four patients with nasal or paranasal cavity SCC who received curative non-surgical therapy (a combination of super-selective arterial cisplatin infusion and radiotherapy) were retrospectively analyzed. From pre-treatment FDG-PET data, a total of 13 parameters of quantitative morphological characteristics (tumor volume, surface area and sphericity), intratumoral characteristics (the maximum and mean standard uptake value, three intratumoral histogram and four textural parameters) and total lesion glycolysis (TLG) were respectively calculated. Information regarding the treatment outcome was determined from the histological diagnosis or clinical follow-up. Each of the 13 quantitative parameters as well as T- and N-stage was assessed for its relation to treatment outcome of local control or failure. Results In univariate analysis, significant differences in surface area and sphericity between the local control and failure groups were observed. The receiver operating characteristic (ROC) curve analysis showed that sphericity had the highest accuracy of 0.88. In the multivariate analysis, sphericity was revealed as an independent predictor of the local control or failure. Conclusions The quantitative parameters of sphericity are useful to predict the treatment outcome in patients with nasal or paranasal SCC.
Collapse
|
119
|
Yamaguchi A, Kudo K, Sato R, Kawata Y, Udo N, Matsushima M, Yabe I, Shirai T, Ochi H, Bito Y. P2‐388: DETECTION OF INCREASED MAGNETIC SUSCEPTIBILITIES IN THE CEREBRAL CORTEX IN PATIENTS WITH ALZHEIMER'S DISEASE: COMPARISON OF QUANTITATIVE SUSCEPTIBILITY MAPPING BETWEEN CONVENTIONAL AND BRAIN SURFACE CORRECTION METHOD. Alzheimers Dement 2018. [DOI: 10.1016/j.jalz.2018.06.1079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
120
|
Sato R, Kudo K, Kawata Y, Udo N, Matsushima M, Yabe I, Yamaguchi A, Shirai T, Bito Y, Ochi H. IC‐P‐188: HYBRID SEQUENCE AND ANALYSIS OF T1‐WEIGHTED IMAGING AND QUANTITATIVE SUSCEPTIBILITY MAPPING FOR EARLY DIAGNOSIS OF ALZHEIMER'S DISEASE. Alzheimers Dement 2018. [DOI: 10.1016/j.jalz.2018.06.2255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
121
|
Yamaguchi A, Kudo K, Sato R, Kawata Y, Udo N, Matsushima M, Yabe I, Shirai T, Ochi H, Bito Y. IC‐P‐194: DETECTION OF INCREASED MAGNETIC SUSCEPTIBILITIES IN THE CEREBRAL CORTEX IN PATIENTS WITH ALZHEIMER'S DISEASE: COMPARISON OF QUANTITATIVE SUSCEPTIBILITY MAPPING BETWEEN CONVENTIONAL AND BRAIN SURFACE CORRECTION METHOD. Alzheimers Dement 2018. [DOI: 10.1016/j.jalz.2018.06.2261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
122
|
Sato R, Kudo K, Kawata Y, Udo N, Matsushima M, Yabe I, Yamaguchi A, Shirai T, Bito Y, Ochi H. P2‐384: HYBRID SEQUENCE AND ANALYSIS OF T1‐WEIGHTED IMAGING AND QUANTITATIVE SUSCEPTIBILITY MAPPING FOR EARLY DIAGNOSIS OF ALZHEIMER'S DISEASES. Alzheimers Dement 2018. [DOI: 10.1016/j.jalz.2018.06.1075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
123
|
Houkin K, Shichinohe H, Abe K, Arato T, Dezawa M, Honmou O, Horie N, Katayama Y, Kudo K, Kuroda S, Matsuyama T, Miyai I, Nagata I, Niizuma K, Sakushima K, Sasaki M, Sato N, Sawanobori K, Suda S, Taguchi A, Tominaga T, Yamamoto H, Yamashita T, Yoshimine T. Accelerating Cell Therapy for Stroke in Japan: Regulatory Framework and Guidelines on Development of Cell-Based Products. Stroke 2018; 49:e145-e152. [PMID: 29581346 DOI: 10.1161/strokeaha.117.019216] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Revised: 01/19/2018] [Accepted: 02/02/2018] [Indexed: 01/10/2023]
|
124
|
Kameda H, Kudo K, Matsuda T, Harada T, Iwadate Y, Uwano I, Yamashita F, Yoshioka K, Sasaki M, Shirato H. Improvement of the repeatability of parallel transmission at 7T using interleaved acquisition in the calibration scan. J Magn Reson Imaging 2017; 48:94-101. [PMID: 29205623 DOI: 10.1002/jmri.25903] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2017] [Accepted: 11/07/2017] [Indexed: 11/07/2022] Open
Abstract
BACKGROUND Respiration-induced phase shift affects B0 /B1+ mapping repeatability in parallel transmission (pTx) calibration for 7T brain MRI, but is improved by breath-holding (BH). However, BH cannot be applied during long scans. PURPOSE To examine whether interleaved acquisition during calibration scanning could improve pTx repeatability and image homogeneity. STUDY TYPE Prospective. SUBJECTS Nine healthy subjects. FIELD STRENGTH/SEQUENCE 7T MRI with a two-channel RF transmission system was used. ASSESSMENT Calibration scanning for B0 /B1+ mapping was performed under sequential acquisition/free-breathing (Seq-FB), Seq-BH, and interleaved acquisition/FB (Int-FB) conditions. The B0 map was calculated with two echo times, and the B1+ map was obtained using the Bloch-Siegert method. Actual flip-angle imaging (AFI) and gradient echo (GRE) imaging were performed using pTx and quadrature-Tx (qTx). All scans were acquired in five sessions. Repeatability was evaluated using intersession standard deviation (SD) or coefficient of variance (CV), and in-plane homogeneity was evaluated using in-plane CV. STATISTICAL TESTS A paired t-test with Bonferroni correction for multiple comparisons was used. RESULTS The intersession CV/SDs for the B0 /B1+ maps were significantly smaller in Int-FB than in Seq-FB (Bonferroni-corrected P < 0.05 for all). The intersession CVs for the AFI and GRE images were also significantly smaller in Int-FB, Seq-BH, and qTx than in Seq-FB (Bonferroni-corrected P < 0.05 for all). The in-plane CVs for the AFI and GRE images in Seq-FB, Int-FB, and Seq-BH were significantly smaller than in qTx (Bonferroni-corrected P < 0.01 for all). DATA CONCLUSION Using interleaved acquisition during calibration scans of pTx for 7T brain MRI improved the repeatability of B0 /B1+ mapping, AFI, and GRE images, without BH. LEVEL OF EVIDENCE 1 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2017.
Collapse
|
125
|
Kudo K, Harada T, Kameda H, Uwano I, Yamashita F, Higuchi S, Yoshioka K, Sasaki M. Indirect Proton MR Imaging and Kinetic Analysis of 17O-Labeled Water Tracer in the Brain. Magn Reson Med Sci 2017; 17:223-230. [PMID: 29142152 PMCID: PMC6039783 DOI: 10.2463/mrms.mp.2017-0094] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Purpose: The feasibility of steady-state sequences for 17O imaging was evaluated based on a kinetic analysis of the brain parenchyma and cerebrospinal fluid (CSF). Materials and Methods: The institutional review board approved this prospective study with written informed consent. Dynamic 2D or 3D steady-state sequences were performed in five and nine participants, respectively, with different parameters using a 3T scanner. During two consecutive dynamic scans, saline was intravenously administered for control purposes in the first scan, and 20% 17O-labeled water (1 mL/Kg) was administered in the second scan. Signal changes relative to the baseline were calculated, and kinetic analyses of the curves were conducted for all voxels. Region of interest analysis was performed in the brain parenchyma, choroid plexus, and CSF spaces. Results: Average signal drops were significantly larger in the 17O group than in the controls for most of the imaging parameters. Different kinetic parameters were observed between the brain parenchyma and CSF spaces. Average and maximum signal drops were significantly larger in the CSF spaces and choroid plexus than in the brain parenchyma. Bolus arrival, time to peak, and the first moment of dynamic curves of 17O in the CSF space were delayed compared to that in the brain parenchyma. Significant differences between the ventricle and subarachnoid space were also noted. Conclusion: Steady-state sequences are feasible for indirect 17O imaging with reasonable temporal resolution; this result is potentially important for the analysis of water kinetics and aquaporin function for several disorders.
Collapse
|