1
|
Khan J, Kim ND, Bromhead C, Truman P, Kruger MC, Mallard BL. Hepatotoxicity of titanium dioxide nanoparticles. J Appl Toxicol 2025; 45:23-46. [PMID: 38740968 PMCID: PMC11634566 DOI: 10.1002/jat.4626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Revised: 04/21/2024] [Accepted: 04/25/2024] [Indexed: 05/16/2024]
Abstract
The food additive E171 (titanium dioxide, TiO2), is widely used in foods, pharmaceuticals and cosmetics. It is a fine white powder, with at least one third of its particles sized in the nanoparticulate (˂100 nm range, TiO2 NPs). The use of E171 is controversial as its relevant risk assessment has never been satisfactorily accomplished. In vitro and in vivo studies have shown dose-dependent toxicity in various organs including the liver. TiO2 NPs have been shown to induce inflammation, cell death and structural and functional changes within the liver. The toxicity of TiO2 NPs in experimental models varies between organs and according to their physiochemical characteristics and parameters such as dosage and route of administration. Among these factors, ingestion is the most significant exposure route, and the liver is a key target organ. The aim of this review is to highlight the reported adverse effects of orally administered TiO2 NPs on the liver and to discuss the controversial state of its toxicity.
Collapse
Affiliation(s)
- Jangrez Khan
- School of Health SciencesMassey UniversityPO Box 756Wellington6021New Zealand
| | - Nicholas D. Kim
- School of Health SciencesMassey UniversityPO Box 756Wellington6021New Zealand
| | - Collette Bromhead
- School of Health SciencesMassey UniversityPO Box 756Wellington6021New Zealand
| | - Penelope Truman
- School of Health SciencesMassey UniversityPO Box 756Wellington6021New Zealand
| | - Marlena C. Kruger
- School of Health SciencesMassey UniversityPO Box 756Wellington6021New Zealand
| | - Beth L. Mallard
- School of Health SciencesMassey UniversityPO Box 756Wellington6021New Zealand
| |
Collapse
|
2
|
Fokter SK, Ledinek Ž, Kljaić Dujić M, Novak I. Extreme Serum Titanium Concentration Induced by Acetabular Cup Failure: Unveiling a Unique Scenario of Titanium Alloy Debris Accumulation. Bioengineering (Basel) 2024; 11:235. [PMID: 38534509 DOI: 10.3390/bioengineering11030235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 02/12/2024] [Accepted: 02/24/2024] [Indexed: 03/28/2024] Open
Abstract
The majority of contemporary total hip arthroplasty (THA) implants are constructed from Ti alloys, which are generally believed to generate fewer adverse local tissue reactions (ALTRs) compared to CoCr alloys. This study presents a case of unusual primary THA failure where a substantial release of Ti alloy debris was observed. A 52-year-old active male underwent THA after post-traumatic aseptic necrosis of the femoral head in 2006. Seventeen years after the procedure, the patient presented with groin pain and a restricted range of motion. X-rays revealed the protrusion of the alumina ceramic head through the Ti6Al4V acetabular cup. Trace element analysis indicated significantly elevated levels of serum Ti, Al, and V. CT and MRI confirmed Ti alloy cup failure and a severe ALTR. During revision surgery, it was found that the worn-out ceramic head was in direct contact with the acetabular cup, having protruded through a central hole it had created over time. No acetabular liner was found. Histological analysis of his tissue samples showed wear-induced synovitis with areas of multinucleated foreign body giant cells and the accumulation of numerous metal particles but no acute inflammatory response. Six months after the revision THA, the patient has experienced favourable outcomes. This case provides an instructive illustration for studying the consequences of the substantial release of Ti alloy debris from orthopedic implants.
Collapse
Affiliation(s)
- Samo K Fokter
- Clinical Department of Orthopedic Surgery, University Medical Centre Maribor, Ljubljanska 5, 2000 Maribor, Slovenia
- Faculty of Medicine, University of Maribor, Slomškov trg 15, 2000 Maribor, Slovenia
- Faculty of Medicine, University of Ljubljana, Kongresni trg 12, 1000 Ljubljana, Slovenia
| | - Živa Ledinek
- Department of Pathology, University Medical Centre Maribor, Ljubljanska 5, 2000 Maribor, Slovenia
| | - Milka Kljaić Dujić
- Department of Radiology, University Medical Centre Maribor, Ljubljanska 5, 2000 Maribor, Slovenia
| | - Igor Novak
- Clinical Department of Orthopedic Surgery, University Medical Centre Maribor, Ljubljanska 5, 2000 Maribor, Slovenia
| |
Collapse
|
3
|
Kurtz MA, Wessinger AC, Mace A, Moreno-Reyes A, Gilbert JL. Additively manufactured Ti-29Nb-21Zr shows improved oxide polarization resistance versus Ti-6Al-4V in inflammatory simulating solution. J Biomed Mater Res A 2023; 111:1538-1553. [PMID: 37129046 DOI: 10.1002/jbm.a.37552] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 04/12/2023] [Accepted: 04/18/2023] [Indexed: 05/03/2023]
Abstract
Retrieval studies in the past two decades show severe corrosion of titanium and its alloys in orthopedic implants. This damage is promoted by mechanically assisted crevice corrosion (MACC), particularly within modular titanium-titanium junctions. During MACC, titanium interfaces may be subject to negative potentials and reactive oxygen species (ROS), generated from cathodic activation and/or inflammation. Additive manufacturing (AM) may be able to produce new, corrosion-resistant titanium alloys and admixtures that are less susceptible to these adverse electrochemical events. In this study, we characterize the impedance and corrosion properties of three new AM titanium materials, including Ti-6Al-4V with added 1% nano-yttria stabilized ZrO2 , admixed Ti-29Nb-21Zr, and pre-alloyed Ti-29Nb-21Zr. We aim to elucidate how these materials perform when subjected to high ROS solutions. We include conventionally and additively manufactured Ti-6Al-4V in our study as comparison groups. A 0.1 M H2 O2 phosphate-buffered saline (PBS) solution, simulating inflammatory conditions, significantly increased biomaterial OCP (-0.14 V vs. Ag/AgCl) compared to PBS only (-0.38 V, p = .000). During anodic polarization, Ti-6Al-4V passive current density more than doubled from 1.28 × 10-7 to 3.81 × 10-7 A/cm2 when exposed to 0.1 M H2 O2 . In contrast, Ti-29Nb-21Zr passive current density remained relatively unchanged, slightly increasing from 7.49 × 10-8 in PBS to 9.31 × 10-8 in 0.1 M H2 O2 . Ti-29Nb-21Zr oxide polarization resistance (Rp ) was not affected by 0.1 M H2 O2 , maintaining a high value (1.09 × 106 vs. 1.89 × 106 Ω cm2 ), while Ti-6Al-4V in 0.1 M H2 O2 solution had significantly diminished Rp (4.38 × 106 in PBS vs. 7.24 × 104 Ω cm2 in H2 O2 ). These results indicate that Ti-29Nb-21Zr has improved corrosion resistance in ROS containing solutions when compared with Ti-6Al-4V based biomaterials.
Collapse
Affiliation(s)
- Michael A Kurtz
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
- The Clemson University-Medical University of South Carolina Bioengineering Program, Charleston, South Carolina, USA
| | - Audrey C Wessinger
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
- The Clemson University-Medical University of South Carolina Bioengineering Program, Charleston, South Carolina, USA
| | - Annsley Mace
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
- The Clemson University-Medical University of South Carolina Bioengineering Program, Charleston, South Carolina, USA
| | - Aldo Moreno-Reyes
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
- The Clemson University-Medical University of South Carolina Bioengineering Program, Charleston, South Carolina, USA
| | - Jeremy L Gilbert
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
- The Clemson University-Medical University of South Carolina Bioengineering Program, Charleston, South Carolina, USA
| |
Collapse
|
4
|
Corrosion evaluation of Ti–6Al–4V manufactured by electron beam melting in Ringer’s physiological solution: an in vitro study of the passive film. J APPL ELECTROCHEM 2022. [DOI: 10.1007/s10800-022-01683-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
5
|
Esteban J, Vallet-Regí M, Aguilera-Correa JJ. Antibiotics- and Heavy Metals-Based Titanium Alloy Surface Modifications for Local Prosthetic Joint Infections. Antibiotics (Basel) 2021; 10:1270. [PMID: 34680850 PMCID: PMC8532710 DOI: 10.3390/antibiotics10101270] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 10/05/2021] [Accepted: 10/13/2021] [Indexed: 01/04/2023] Open
Abstract
Prosthetic joint infection (PJI) is the second most common cause of arthroplasty failure. Though infrequent, it is one of the most devastating complications since it is associated with great personal cost for the patient and a high economic burden for health systems. Due to the high number of patients that will eventually receive a prosthesis, PJI incidence is increasing exponentially. As these infections are provoked by microorganisms, mainly bacteria, and as such can develop a biofilm, which is in turn resistant to both antibiotics and the immune system, prevention is the ideal approach. However, conventional preventative strategies seem to have reached their limit. Novel prevention strategies fall within two broad categories: (1) antibiotic- and (2) heavy metal-based surface modifications of titanium alloy prostheses. This review examines research on the most relevant titanium alloy surface modifications that use antibiotics to locally prevent primary PJI.
Collapse
Affiliation(s)
- Jaime Esteban
- Clinical Microbiology Department, Jiménez Díaz Foundation Health Research Institute, Autonomous University of Madrid, Av. Reyes Católicos 2, 28040 Madrid, Spain
- Networking Research Centre on Infectious Diseases (CIBER-ID), 28029 Madrid, Spain
| | - María Vallet-Regí
- Department of Chemistry in Pharmaceutical Sciences, Research Institute Hospital 12 de Octubre (i+12), School of Pharmacy, Complutense University of Madrid, Pza. Ramón y Cajal s/n, 28040 Madrid, Spain
- Networking Research Centre on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 28029 Madrid, Spain
| | - John J Aguilera-Correa
- Networking Research Centre on Infectious Diseases (CIBER-ID), 28029 Madrid, Spain
- Department of Chemistry in Pharmaceutical Sciences, Research Institute Hospital 12 de Octubre (i+12), School of Pharmacy, Complutense University of Madrid, Pza. Ramón y Cajal s/n, 28040 Madrid, Spain
| |
Collapse
|
6
|
Lukaszewska-Kuska M, Wirstlein P, Majchrowski R, Dorocka-Bobkowska B. The effects of titanium topography and chemical composition on human osteoblast cell. Physiol Res 2021; 70:413-423. [PMID: 33982574 DOI: 10.33549/physiolres.934582] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The objective of this study was to evaluate and compare titanium surfaces: machined (MA); sintered ceramic-blasted (HAS); sintered ceramic-blasted and acid-etched (HAS DE) and to determine the effects of surface topography, roughness and chemical composition on human osteoblast cell reaction. Titanium surface samples were analyzed with respect to surface chemical composition, topography, and roughness. The effects of material surface characteristics on osteoblasts was examined by analyzing osteoblast morphology, viability and differentiation. Osteoblasts cultured on these materials had attached, spread and proliferated on every sample. The viability of osteoblasts cultured on HAS and HAS DE samples increased more intensively in time comparing to MA sample. The viability of osteoblast cultured on HAS samples increased more intensively in the early phases of culture while for cells cultured on HAS DE the cells viability increased later in time. Alkaline phosphate activity was the highest for the cells cultured on HAS sample and statistically higher than for the MA sample. The least activity occurred on the smooth MA sample along with the rougher HAS DE samples. All the examined samples were found to be biocompatible, as indicated by cell attachment, proliferation, and differentiation. Titanium surfaces modification improved the dynamics of osteoblast viability increase. Osteoblast differentiation was found to be affected by the etching procedure and presence of Ca and P on the surface.
Collapse
Affiliation(s)
- M Lukaszewska-Kuska
- Department of Gerodontology and Oral Pathology, University of Medical Sciences Poznan, Poznan, Poland.
| | | | | | | |
Collapse
|
7
|
Chen W, Zhu WQ, Qiu J. Impact of exogenous metal ions on peri-implant bone metabolism: a review. RSC Adv 2021; 11:13152-13163. [PMID: 35423842 PMCID: PMC8697588 DOI: 10.1039/d0ra09395e] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 03/25/2021] [Indexed: 11/21/2022] Open
Abstract
The development of effective methods to promote the osseointegration of dental implants by surface modification is an area of intense research in dental materials science. Exogenous metal ions present in the implant and surface modifications are closely related to the bone metabolism around the implant. In the complex oral microenvironment, the release of metal ions caused by continuous corrosion of dental implants has an unfavorable impact on the surrounding tissue, and then affects osseointegration, leading to bad results such as loosening and falling off in the late stage of the implant. Besides, these ions can even be distributed in distant tissues and organs. Currently, surface modification techniques are being developed that involve different processing technologies including the introduction of exogenous metal ions with different properties onto the surface of implants to improve performance. However, most metal elements have some level of biological toxicity and can only be used within a safe concentration range to exert the optimum biological effects on recipients. In this paper, we review the adverse effects of metal ions on osseointegration and highlight the emerging applications for metal elements in improving the performance of dental implants.
Collapse
Affiliation(s)
- Wei Chen
- Department of Oral Implantology, Affiliated Hospital of Stomatology, Nanjing Medical University Nanjing 210029 PR China +86 25 69593085
- Jiangsu Key Laboratory of Oral Disease, Nanjing Medical University Nanjing 210029 PR China
| | - Wen-Qing Zhu
- Department of Oral Implantology, Affiliated Hospital of Stomatology, Nanjing Medical University Nanjing 210029 PR China +86 25 69593085
- Jiangsu Key Laboratory of Oral Disease, Nanjing Medical University Nanjing 210029 PR China
| | - Jing Qiu
- Department of Oral Implantology, Affiliated Hospital of Stomatology, Nanjing Medical University Nanjing 210029 PR China +86 25 69593085
- Jiangsu Key Laboratory of Oral Disease, Nanjing Medical University Nanjing 210029 PR China
| |
Collapse
|
8
|
Fukuda R, Matsuoka M, Onodera T, Iwasaki K, Tanaka D, Hiraga H, Kanno-Okada H, Matsuno Y, Kondo E, Iwasaki N. Angiosarcoma after revision total knee arthroplasty. Knee 2021; 28:151-158. [PMID: 33360381 DOI: 10.1016/j.knee.2020.11.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Revised: 11/04/2020] [Accepted: 11/23/2020] [Indexed: 02/02/2023]
Abstract
BACKGROUND Hemarthrosis after total knee arthroplasty (TKA) is a relatively rare complication. Although most cases are effectively treated with conservative therapy, some cases require angiographic embolization or surgical intervention. Angiosarcoma is a rare malignant tumor derived from the vascular endothelium with neovascular hyperplasia and mainly arises in the skin and superficial soft tissue, and less frequently in deep soft tissue and bone. Although malignant neoplasms such as angiosarcoma in the vicinity of orthopedic implants were reported, the causal relationship between development of the malignant tumor and the orthopedic implant is widely debated in the literature. CASE PRESENTATION We report the case of a 68-year-old female with angiosarcoma that developed in the knee joint 2 years after revision TKA. The patient exhibited severe persistent bleeding, which reached 1000-1400 ml per day for 4 months. Histological analysis of the synovial tissue in the knee joint showed large cells with nuclear atypia. Immunohistochemical staining showed cells that were positive for CD31, CD34, and D2-40, and she was diagnosed with angiosarcoma. The patient underwent an amputation at the level of the thigh, and her general condition immediately improved after the operation. The patient did not exhibit bleeding from the site of amputation, and no local recurrence or distant metastases were detected 1 year after the amputation. CONCLUSIONS To the best of our knowledge, this represents the first report of angiosarcoma 2 years after revision TKA. Further careful follow up is needed, given the high-grade malignancy.
Collapse
Affiliation(s)
- Ryuichi Fukuda
- Department of Orthopedic Surgery, Hokkaido University Graduate School of Medicine, Sapporo, Hokkaido, Japan; Department of Orthopedic Surgery, Teine Keijinkai Hospital, Teine-Ku, Sapporo, Hokkaido, Japan.
| | - Masatake Matsuoka
- Department of Orthopedic Surgery, Hokkaido University Graduate School of Medicine, Sapporo, Hokkaido, Japan.
| | - Tomohiro Onodera
- Department of Orthopedic Surgery, Hokkaido University Graduate School of Medicine, Sapporo, Hokkaido, Japan.
| | - Koji Iwasaki
- Department of Functional Reconstruction for the Knee Joint, Hokkaido University, Sapporo, Hokkaido, Japan.
| | - Daisuke Tanaka
- Department of Orthopaedic Surgery, Eniwa Hospital, Eniwa-Shi, Hokkaido, Japan.
| | - Hiroaki Hiraga
- Department of Musculoskeletal Oncology, Hokkaido Cancer Center, Shiroishi-Ku, Sapporo, Hokkaido, Japan.
| | - Hiromi Kanno-Okada
- Department of Surgical Pathology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan.
| | - Yoshihiro Matsuno
- Department of Surgical Pathology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan.
| | - Eiji Kondo
- Centre for Sports Medicine, Hokkaido University Hospital, Sapporo, Hokkaido, Japan.
| | - Norimasa Iwasaki
- Department of Orthopedic Surgery, Hokkaido University Graduate School of Medicine, Sapporo, Hokkaido, Japan.
| |
Collapse
|
9
|
The Influence of Bovine Serum Albumin Modified Titanium Dioxide Nanoparticles on Myoblast Cytotoxicity. Pharm Chem J 2020. [DOI: 10.1007/s11094-020-02292-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
10
|
Tang KM, Chen W, Tang ZH, Yu XY, Zhu WQ, Zhang SM, Qiu J. Role of the Hippo-YAP/NF-κB signaling pathway crosstalk in regulating biological behaviors of macrophages under titanium ion exposure. J Appl Toxicol 2020; 41:561-571. [PMID: 33058278 DOI: 10.1002/jat.4065] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 08/19/2020] [Accepted: 08/21/2020] [Indexed: 12/26/2022]
Abstract
The presence of metal ions, such as titanium (Ti) ions, is toxic to adjacent tissues of implants. Indeed, Ti ions may induce an inflammatory response through the NF-κB pathway, thus causing damage to soft and hard tissues. The involvement of Yes-associated protein (YAP), a key factor of the Hippo pathway, in an immuno-inflammatory response has been confirmed, whereas its role in Ti ion-mediated inflammation has not been elucidated. Therefore, this study aimed to investigate the role of signal crosstalk between the Hippo/YAP and NF-κB signaling pathways in the pro-inflammatory effect of Ti ions on macrophages. In our work, RAW264.7 cells were cocultured with Ti ions. The migration capacity of macrophages under Ti ion exposure was measured by transwell assay. Western blot analysis was used to detect the expressions of related proteins. Polymerase chain reaction was used to evaluate the expression of pro-inflammatory cytokines. The nucleus translocation of YAP and P65 was visualized and analyzed via immunofluorescence staining. The results showed that the migration of macrophages was promoted under Ti ion exposure. Ten parts per million Ti ions induced nuclear expression of YAP and activated the NF-κB pathway, which finally upregulated the expression of pro-inflammatory cytokines in macrophages. Moreover, the inhibition of the NF-κB pathway rescued the reduction of YAP expression under Ti ion exposure. Most importantly, the overexpression of YAP exacerbated the inflammatory response mediated by Ti ions through the NF-κB pathway. In summary, this study explored the mechanism of Hippo-YAP/NF-κB pathway crosstalk involved in the regulation of macrophage behaviors under Ti ion exposure.
Collapse
Affiliation(s)
- Kai-Ming Tang
- Department of Oral Implantology, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China.,Jiangsu Key Laboratory of Oral Disease, Nanjing Medical University, Nanjing, China
| | - Wei Chen
- Department of Oral Implantology, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China.,Jiangsu Key Laboratory of Oral Disease, Nanjing Medical University, Nanjing, China
| | - Ze-Hua Tang
- Department of Oral Implantology, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China.,Jiangsu Key Laboratory of Oral Disease, Nanjing Medical University, Nanjing, China
| | - Xiao-Yu Yu
- Department of Oral Implantology, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China.,Jiangsu Key Laboratory of Oral Disease, Nanjing Medical University, Nanjing, China
| | - Wen-Qing Zhu
- Department of Oral Implantology, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China.,Jiangsu Key Laboratory of Oral Disease, Nanjing Medical University, Nanjing, China
| | - Song-Mei Zhang
- Department of General Dentistry, Eastman Institute for Oral Health, University of Rochester, Rochester, New York, USA
| | - Jing Qiu
- Department of Oral Implantology, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China.,Jiangsu Key Laboratory of Oral Disease, Nanjing Medical University, Nanjing, China
| |
Collapse
|
11
|
Elevated Serum Titanium Levels in Children With Early Onset Scoliosis Treated With Growth-friendly Instrumentation. J Pediatr Orthop 2020; 40:e420-e423. [PMID: 32501902 DOI: 10.1097/bpo.0000000000001463] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND A previous study showed significantly higher serum titanium levels in patients with early-onset scoliosis (EOS) treated with traditional growing rods (TGR) and magnetically controlled growing rods (MCGR) compared with controls. Children with vertical expandable prosthetic titanium rib (VEPTR) were not assessed. The purpose of this study was to compare serum titanium levels in EOS patients treated with TGR, MCGR, and VEPTR. We hypothesized that EOS patients treated with all forms of growth-friendly instrumentation (GFI) have elevated serum titanium levels. METHODS This was a prospective cross-sectional case series. Serum titanium levels were collected from patients with GFI who were enrolled in an EOS database. Blood samples were collected at a clinic visit or lengthening/exchange procedure between April and December 2018. The normal range for serum titanium is 0 to 1 ng/mL. Analyses were conducted using analysis of variance and Bonferroni post hoc test. RESULTS A total of 23 patients (2 TGR, 8 MCGR, 13 VEPTR) were analyzed. There was a significant difference in age at the time of blood sample collection (12.5 vs. 9.8 vs. 7.5 y, P=0.015) and serum titanium level (1.5 vs. 4.5 vs. 7.6 ng/mL, P=0.021) between TGR, MCGR, and VEPTR, respectively. All of the MCGR and VEPTR patients had a serum titanium level ≥2 ng/mL. Binary comparisons showed that VEPTR had a significantly higher serum titanium level than TGR (P=0.046). There was no difference in serum titanium level when MCGR was compared with TGR and VEPTR. Time from implant insertion to blood sample collection, number of rods currently implanted, total number of rods implanted throughout treatment, and number of lengthenings per patient was similar between the groups. CONCLUSIONS Elevated serum titanium levels may be present in EOS patients treated with all forms of GFI. Although our TGR patients had indwelling implants for the longest period of time, they had the lowest serum titanium level. Repetitive chest wall motion during respiration may lead to continued wear and metal ion release with VEPTR. LEVEL OF EVIDENCE Level II-therapeutic.
Collapse
|
12
|
Biological Monitoring of Metal Ions Released from Hip Prostheses. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17093223. [PMID: 32384733 PMCID: PMC7246585 DOI: 10.3390/ijerph17093223] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 04/24/2020] [Accepted: 05/04/2020] [Indexed: 01/06/2023]
Abstract
The aim of this study was to evaluate the levels of As, Be, Bi, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Se, Tl, V, and Zn, by inductively coupled plasma-mass spectrometry (ICP-MS) in the urine of two groups of patients with two different types of metal-on-metal (MoM) total hip prostheses (ASR DePuy®, group A, 25 patients; total Met-Met System Lima®, group B, 28 patients). The determination of metals reflected a steady-state release (group A: 9 years after surgery and group B: 6 years after surgery). The results obtained confirmed the increase of Co and Cr urinary levels in both group when compared with the reference values for the general population adopted by the Italian Society of Reference Values (SIVR). In particular, Co and Cr levels exceeded the threshold values in urine, respectively, of 30 μg and 21 µg, adjusted to creatinine based on the threshold in whole blood of 7 μg/L proposed by the Medicines and Healthcare Products Regulatory Agency (MHRA). Regarding the other investigated metals, significantly higher values were found in Group A than in Group B. These differences could be due to the type of hip prosthesis implanted, the longer period of time since the implantation, as well as many other factors such as diet, age, drug consumption, physical activity, or presence of dental fillings. The continuous monitoring over the years of metal concentrations in patients carrying a prosthesis could be useful to better identify the sources of these metals.
Collapse
|
13
|
The Implications of Titanium Alloys Applied in Maxillofacial Osteosynthesis. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10093203] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Titanium alloys are known for their biological, mechanical and chemical properties, which have successfully expanded their use in the maxillofacial field. The internal fixation using titanium miniplates and screws offer a new perspective for the treatment of trauma and in orthognathic surgery and maxillofacial oncology. Although, titanium is highly recommended for its excellent biocompatibility, recent research has focused on identifying the potential local and general implications of the interactions between the human tissue and the metallic particles. This present review aims to outline the existing tissue changes, cellular alterations and future perspectives regarding the use of titanium-based alloys as osteosynthesis materials, taking into consideration the existing present debate whether the routinely removal of these materials should be an indication.
Collapse
|
14
|
Sengodan V, Doddihithlu S. Analysis of hematological metal element levels in orthopedic patients with implants. J Nat Sci Biol Med 2020. [DOI: 10.4103/jnsbm.jnsbm_120_19] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
15
|
Swiatkowska I, Martin NG, Henckel J, Apthorp H, Hamshere J, Hart AJ. Blood and plasma titanium levels associated with well-functioning hip implants. J Trace Elem Med Biol 2020; 57:9-17. [PMID: 31546210 DOI: 10.1016/j.jtemb.2019.09.005] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Revised: 08/28/2019] [Accepted: 09/13/2019] [Indexed: 01/13/2023]
Abstract
BACKGROUND Hip implants are usually manufactured from cobalt-chromium and titanium alloys. As the implants wear and corrode, metal debris is released into the surrounding tissue and blood, providing a potential biomarker for their function. Whilst there are laboratory reference levels for blood cobalt and chromium in patients with well and poorly functioning hip implants, there are no such guidelines for titanium. This is despite the increasing use of titanium implants worldwide. PATIENTS AND METHODS We recruited a consecutive series of 95 patients (mean age 71 years, mean time after surgery 8.5 years) with one hip implant type, inserted by the same surgeon. We assessed clinical and radiological outcome, and measured blood and plasma titanium using high resolution inductively-coupled plasma mass spectrometry. RESULTS The upper normal reference limit for blood and plasma titanium was 2.20 and 2.56 μg L-1, respectively, and did not differ significantly between males and females. CONCLUSION We are the first to propose a laboratory reference level for blood and plasma titanium in patients with well-functioning titanium hip implants. This is an essential starting point for further studies to explore the clinical usefulness of blood titanium as a biomarker of orthopaedic implant performance, and comes at a time of considerable controversy regarding the use of certain titanium alloys in hip arthroplasty.
Collapse
Affiliation(s)
- Ilona Swiatkowska
- Institute of Orthopaedics and Musculoskeletal Science, University College London, HA7 4LP Stanmore, UK.
| | - Nicholas G Martin
- Trace Element Laboratory, North West London Pathology, Charing Cross Hospital, W6 8RF London, UK
| | - Johann Henckel
- Royal National Orthopaedic Hospital, Stanmore, HA7 4LP Stanmore, UK
| | | | | | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London, HA7 4LP Stanmore, UK; Royal National Orthopaedic Hospital, Stanmore, HA7 4LP Stanmore, UK
| |
Collapse
|
16
|
Ferraro SA, Domingo MG, Etcheverrito A, Olmedo DG, Tasat DR. Neurotoxicity mediated by oxidative stress caused by titanium dioxide nanoparticles in human neuroblastoma (SH-SY5Y) cells. J Trace Elem Med Biol 2020; 57:126413. [PMID: 31606305 DOI: 10.1016/j.jtemb.2019.126413] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Revised: 09/17/2019] [Accepted: 09/24/2019] [Indexed: 12/30/2022]
Abstract
BACKGROUND Titanium is widely used in biomedicine. Due to biotribocorrosion, titanium dioxide (TiO2) nanoparticles (NPs) can be released from the titanium implant surface, enter the systemic circulation, and migrate to various organs and tissues including the brain. A previous study showed that 5 nm TiO2 NPs reached the highest concentration in the brain. Even though TiO2 NPs are believed to possess low toxicity, little is known about their neurotoxic effects. The aim of the study was to evaluate in vitro the effects of 5 nm TiO2 NPs on a human neuroblastoma (SH-SY5Y) cell line. METHODS Cell cultures were divided into non-exposed and exposed to TiO2 NPs for 24 h. The following were evaluated: reactive oxygen species (ROS) generation, apoptosis, cellular antioxidant response, endoplasmic reticulum stress and autophagy. RESULTS Exposure to TiO2 NPs induced ROS generation in a dose dependent manner, with values reaching up to 10 fold those of controls (p < 0.001). Nrf2 nuclear localization and autophagy, also increased in a dose dependent manner. Apoptosis increased by 4- to 10-fold compared to the control group, depending on the dose employed. CONCLUSIONS Our results show that TiO2 NPs cause ROS increase, induction of ER stress, Nrf2 cytoplasmic translocation to the nucleus and apoptosis. Thus, neuroblastoma cell response to TiO2 NPs may be associated with an imbalance of the oxidative metabolism where endoplasmic reticulum-mediated signal pathway seems to be the main neurotoxic mechanism.
Collapse
Affiliation(s)
- Sebastián Ariel Ferraro
- Center of Studies in Health and Environment, School of Science and Technology, National University of San Martín, San Martín, Buenos Aires, Argentina; National Council of Scientific and Technical Research (CONICET), Buenos Aires, Argentina.
| | - Mariela Gisele Domingo
- Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Anatomía Patológica, Buenos Aires, Argentina; Research Fellow of the University of Buenos Aires, Buenos Aires, Argentina.
| | - Analía Etcheverrito
- Center of Studies in Health and Environment, School of Science and Technology, National University of San Martín, San Martín, Buenos Aires, Argentina.
| | - Daniel Gustavo Olmedo
- National Council of Scientific and Technical Research (CONICET), Buenos Aires, Argentina; Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Anatomía Patológica, Buenos Aires, Argentina.
| | - Deborah Ruth Tasat
- Center of Studies in Health and Environment, School of Science and Technology, National University of San Martín, San Martín, Buenos Aires, Argentina; Universidad de Buenos Aires, Facultad de Odontología, Cátedra de Histología y Embriología, Buenos Aires, Argentina.
| |
Collapse
|
17
|
Abstract
Osseointegration was originally defined as a direct structural and functional connection between ordered living bone and the surface of a load-carrying implant. It is now said that an implant is regarded as osseointegrated when there is no progressive relative movement between the implant and the bone with which it is in direct contact. Although the term osseointegration was initially used with reference to titanium metallic implants, the concept is currently applied to all biomaterials that have the ability to osseointegrate. Biomaterials are closely related to the mechanism of osseointegration; these materials are designed to be implanted or incorporated into the living system with the aims to substitute for, or regenerate, tissues and tissue functions. Objective evaluation of the properties of the different biomaterials and of the factors that influence bone repair in general, and at the bone tissue-implant interface, is essential to the clinical success of an implant. The Biomaterials Laboratory of the Oral Pathology Department of the School of Dentistry at the University of Buenos Aires is devoted to the study and research of the properties and biological effects of biomaterials for dental implants and bone substitutes. This paper summarizes the research work resulting from over 25 years' experience in this field. It includes studies conducted at our laboratory on the local and systemic factors affecting the peri-implant bone healing process, using experimental models developed by our research team. The results of our research on corrosion, focusing on dental implants, as well as our experience in the evaluation of failed dental implants and bone biopsies obtained following maxillary sinus floor augmentation with bone substitutes, are also reported. Research on biomaterials and their interaction with the biological system is a continuing challenge in biomedicine, which aims to achieve optimal biocompatibility and thus contribute to patient health.
Collapse
Affiliation(s)
- María B Guglielmotti
- Department of Oral Pathology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina.,National Research Council (CONICET), Buenos Aires, Argentina
| | - Daniel G Olmedo
- Department of Oral Pathology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina.,National Research Council (CONICET), Buenos Aires, Argentina
| | - Rómulo L Cabrini
- Department of Oral Pathology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina.,Department of Radiobiology, National Atomic Energy Commission, Buenos Aires, Argentina
| |
Collapse
|
18
|
Björnmalm M, Wong LM, Wojciechowski JP, Penders J, Horgan CC, Booth MA, Martin NG, Sattler S, Stevens MM. In vivo biocompatibility and immunogenicity of metal-phenolic gelation. Chem Sci 2019; 10:10179-10194. [PMID: 31700596 PMCID: PMC6837883 DOI: 10.1039/c9sc03325d] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Accepted: 09/13/2019] [Indexed: 12/19/2022] Open
Abstract
In vivo forming hydrogels are of interest for diverse biomedical applications due to their ease-of-use and minimal invasiveness and therefore high translational potential. Supramolecular hydrogels that can be assembled using metal-phenolic coordination of naturally occurring polyphenols and group IV metal ions (e.g. TiIV or ZrIV) provide a versatile and robust platform for engineering such materials. However, the in situ formation and in vivo response to this new class of materials has not yet been reported. Here, we demonstrate that metal-phenolic supramolecular gelation occurs successfully in vivo and we investigate the host response to the material over 14 weeks. The TiIV-tannic acid materials form stable gels that are well-tolerated following subcutaneous injection. Histology reveals a mild foreign body reaction, and titanium biodistribution studies show low accumulation in distal tissues. Compared to poloxamer-based hydrogels (commonly used for in vivo gelation), TiIV-tannic acid materials show a substantially improved in vitro drug release profile for the corticosteroid dexamethasone (from <1 day to >10 days). These results provide essential in vivo characterization for this new class of metal-phenolic hydrogels, and highlight their potential suitability for biomedical applications in areas such as drug delivery and regenerative medicine.
Collapse
Affiliation(s)
- Mattias Björnmalm
- Department of Materials
, Department of Bioengineering
, Institute of Biomedical Engineering
, Imperial College London
,
London SW7 2AZ
, UK
.
| | - Lok Man Wong
- National Heart and Lung Institute
, Imperial College London
,
London W12 0NN
, UK
.
| | - Jonathan P. Wojciechowski
- Department of Materials
, Department of Bioengineering
, Institute of Biomedical Engineering
, Imperial College London
,
London SW7 2AZ
, UK
.
| | - Jelle Penders
- Department of Materials
, Department of Bioengineering
, Institute of Biomedical Engineering
, Imperial College London
,
London SW7 2AZ
, UK
.
| | - Conor C. Horgan
- Department of Materials
, Department of Bioengineering
, Institute of Biomedical Engineering
, Imperial College London
,
London SW7 2AZ
, UK
.
| | - Marsilea A. Booth
- Department of Materials
, Department of Bioengineering
, Institute of Biomedical Engineering
, Imperial College London
,
London SW7 2AZ
, UK
.
| | - Nicholas G. Martin
- Trace Element Laboratory
, North West London Pathology
,
Charing Cross Hospital
, London W6 8RF
, UK
| | - Susanne Sattler
- National Heart and Lung Institute
, Imperial College London
,
London W12 0NN
, UK
.
| | - Molly M. Stevens
- Department of Materials
, Department of Bioengineering
, Institute of Biomedical Engineering
, Imperial College London
,
London SW7 2AZ
, UK
.
| |
Collapse
|
19
|
De Marchi L, Coppola F, Soares AMVM, Pretti C, Monserrat JM, Torre CD, Freitas R. Engineered nanomaterials: From their properties and applications, to their toxicity towards marine bivalves in a changing environment. ENVIRONMENTAL RESEARCH 2019; 178:108683. [PMID: 31539823 DOI: 10.1016/j.envres.2019.108683] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2019] [Revised: 07/18/2019] [Accepted: 08/20/2019] [Indexed: 05/05/2023]
Abstract
As a consequence of their unique characteristics, the use of Engineered Nanomaterials (ENMs) is rapidly increasing in industrial, agricultural products, as well as in environmental technology. However, this fast expansion and use make likely their release into the environment with particular concerns for the aquatic ecosystems, which tend to be the ultimate sink for this type of contaminants. Considering the settling behaviour of particulates, benthic organisms are more likely to be exposed to these compounds. In this way, the present review aims to summarise the most recent data available from the literature on ENMs behaviour and fate in aquatic ecosystems, focusing on their ecotoxicological impacts towards marine and estuarine bivalves. The selection of ENMs presented here was based on the OECD's Working Party on Manufactured Nanomaterials (WPMN), which involves the safety testing and risk assessment of ENMs. Physical-chemical characteristics and properties, applications, environmental relevant concentrations and behaviour in aquatic environment, as well as their toxic impacts towards marine bivalves are discussed. Moreover, it is also identified the impacts derived from the simultaneous exposure of marine organisms to ENMs and climate changes as an ecologically relevant scenario.
Collapse
Affiliation(s)
- Lucia De Marchi
- Department of Biology & Center for Environmental and Marine Studies (CESAM), University of Aveiro, 3810-193, Aveiro, Portugal; Department of Mechanical Engineering & Center for Mechanical Technology and Automation (TEMA), University of Aveiro, 3810-193, Aveiro, Portugal
| | - Francesca Coppola
- Department of Biology & Center for Environmental and Marine Studies (CESAM), University of Aveiro, 3810-193, Aveiro, Portugal
| | - Amadeu M V M Soares
- Department of Biology & Center for Environmental and Marine Studies (CESAM), University of Aveiro, 3810-193, Aveiro, Portugal
| | - Carlo Pretti
- Department of Veterinary Sciences, University of Pisa, San Piero a Grado, Pisa, 56122, Italy
| | - José M Monserrat
- Universidade Federal Do Rio Grande, FURG, Instituto de Ciências Biológicas (ICB), Av Itália km 8 s/n - Caixa Postal 474, 96200-970, Rio Grande, RS, Brazil
| | - Camilla Della Torre
- Department of Biosciences, University of Milan, Via Celoria 26, 20133, Milano, Italy
| | - Rosa Freitas
- Department of Biology & Center for Environmental and Marine Studies (CESAM), University of Aveiro, 3810-193, Aveiro, Portugal.
| |
Collapse
|
20
|
Razzante MC, Ehredt DJ, Clougherty CO, Kriger SJ, Menninger BA, Behan Dionisopoulos S, Bhakta PJ, Bruning NG. Type IV Cell-Mediated Hypersensitivity Reaction Caused by Titanium Implant Following Double Calcaneal Osteotomy and First Metatarsal-Cuneiform Arthrodesis: A Case Report and Review of the Literature. J Foot Ankle Surg 2019; 58:974-979. [PMID: 31266695 DOI: 10.1053/j.jfas.2018.11.031] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2016] [Indexed: 02/03/2023]
Abstract
Because of their inert character and desired biocompatibility, titanium implants have been universally accepted as safer alternatives to the conventional stainless steel orthopedic implants; however, recent emergence of type IV hypersensitivity reactions to titanium have included eczema, contact dermatitis, a prolonged febrile state, sterile osteonecrosis, and impaired fracture and wound healing. This report presents a patient with postoperative incision dehiscence and devascularization of surfaces in contact with titanium hardware after undergoing a double calcaneal osteotomy and a first metatarsal-cuneiform arthrodesis using titanium alloy implants. Titanium hypersensitivity was confirmed in this case through standard allergy patch testing by a board-certified immunologist. Complete healing occurred after diagnosis of the titanium allergy and hardware explant. To our knowledge, this is one of a few known allergies to titanium implants after foot and ankle surgery.
Collapse
Affiliation(s)
- Mark C Razzante
- Assistant Professor, Department of Podiatric Surgery and Biomechanics, Kent State University College of Medicine, Cleveland, OH.
| | - Duane J Ehredt
- Assistant Professor, Department of Podiatric Surgery and Biomechanics, Kent State University College of Medicine, Cleveland, OH
| | | | - Stephen J Kriger
- Podiatric Surgery Resident, Scripps Mercy Hospital Residency Program, San Diego, CA
| | - Brennan A Menninger
- Podiatric Surgery Resident, North Colorado Medical Center Residency Program, Greeley, CO
| | | | - Parth J Bhakta
- Podiatric Surgery Resident, Hunt Regional Medical Center Residency Program, Greenville, TX
| | - Nicholas G Bruning
- Podiatric Surgery Resident, St. Mary Mercy Livonia Residency Program, Livonia, MI
| |
Collapse
|
21
|
Aguilera-Correa JJ, Auñón Á, Boiza-Sánchez M, Mahillo-Fernández I, Mediero A, Eguibar-Blázquez D, Conde A, Arenas MÁ, de-Damborenea JJ, Cordero-Ampuero J, Esteban J. Urine Aluminum Concentration as a Possible Implant Biomarker of Pseudomonas aeruginosa Infection Using a Fluorine- and Phosphorus-Doped Ti-6Al-4V Alloy with Osseointegration Capacity. ACS OMEGA 2019; 4:11815-11823. [PMID: 31460290 PMCID: PMC6682075 DOI: 10.1021/acsomega.9b00898] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2019] [Accepted: 06/10/2019] [Indexed: 06/10/2023]
Abstract
Joint prosthesis failure is mainly related to aseptic loosening and prosthetic joint infections, both associated with high morbidity and a substantial cost burden for patients and health systems. The development of a biomaterial capable of stimulating bone growth while minimizing bacterial adhesion would reduce the incidence of prosthetic failure. Using an in vivo rabbit model, this study evaluates the osseointegration effect of the fluorine (F)- and phosphorus (P)-doped bottle-shaped nanostructured (bNT) Ti-6Al-4V alloy and effectiveness of monitoring urine aluminum concentration to determine the presence of Pseudomonas aeruginosa infection in Ti-6Al-4V implants. Unlike chemically polished (CP) Ti-6Al-4V alloy implants, bNT Ti-6Al-4V alloy implants promoted osseointegration and showed effectiveness as a biomaterial marker. The bNT Ti-6Al-4V alloy implants were associated with a twofold increase in bone thickness and up to 15% greater bone density compared to the CP alloy. Additionally, bNT Ti-6Al-4V alloy implants allowed for discrimination between P. aeruginosa-infected and noninfected animals for 15 days postoperatively, as indicated by the decrease of aluminum concentration in urine, while this difference was only appreciable over the first 7 days when CP Ti-6Al-4V alloy implants were used. Therefore, bNT Ti-6Al-4V alloys could have clinical applications by detecting the infection and by avoiding aseptic loosening.
Collapse
Affiliation(s)
- John-Jairo Aguilera-Correa
- Clinical Microbiology Department, Joint and Bone Research Unit,
and Experimental Surgery and
Animal Research Service, IIS-Fundación
Jimenez Diaz, UAM. Av. Reyes Católicos, 2, 28040 Madrid, Spain
| | - Álvaro Auñón
- Orthopedic Surgery Service, Pathology Department, and Epidemiology
and Biostatistics
Service, Fundación Jiménez
Díaz University Hospital, Av. Reyes Católicos, 2, 28040 Madrid, Spain
| | - Macarena Boiza-Sánchez
- Orthopedic Surgery Service, Pathology Department, and Epidemiology
and Biostatistics
Service, Fundación Jiménez
Díaz University Hospital, Av. Reyes Católicos, 2, 28040 Madrid, Spain
| | - Ignacio Mahillo-Fernández
- Orthopedic Surgery Service, Pathology Department, and Epidemiology
and Biostatistics
Service, Fundación Jiménez
Díaz University Hospital, Av. Reyes Católicos, 2, 28040 Madrid, Spain
| | - Aranzazu Mediero
- Clinical Microbiology Department, Joint and Bone Research Unit,
and Experimental Surgery and
Animal Research Service, IIS-Fundación
Jimenez Diaz, UAM. Av. Reyes Católicos, 2, 28040 Madrid, Spain
| | - Diego Eguibar-Blázquez
- Clinical Microbiology Department, Joint and Bone Research Unit,
and Experimental Surgery and
Animal Research Service, IIS-Fundación
Jimenez Diaz, UAM. Av. Reyes Católicos, 2, 28040 Madrid, Spain
| | - Ana Conde
- Corrosion
and Material Protection Group, National
Center for Metallurgical Research (CENIM-CSIC), Av. Gregorio del Amo, 8, 28040 Madrid, Spain
| | - María-Ángeles Arenas
- Corrosion
and Material Protection Group, National
Center for Metallurgical Research (CENIM-CSIC), Av. Gregorio del Amo, 8, 28040 Madrid, Spain
| | - Juan-José de-Damborenea
- Corrosion
and Material Protection Group, National
Center for Metallurgical Research (CENIM-CSIC), Av. Gregorio del Amo, 8, 28040 Madrid, Spain
| | - José Cordero-Ampuero
- Department
of Orthopaedic Surgery, University Hospital
La Princesa, c/Diego de León 62, 28006 Madrid, Spain
| | - Jaime Esteban
- Clinical Microbiology Department, Joint and Bone Research Unit,
and Experimental Surgery and
Animal Research Service, IIS-Fundación
Jimenez Diaz, UAM. Av. Reyes Católicos, 2, 28040 Madrid, Spain
| |
Collapse
|
22
|
Swiatkowska I, Martin N, Hart AJ. Blood titanium level as a biomarker of orthopaedic implant wear. J Trace Elem Med Biol 2019; 53:120-128. [PMID: 30910194 DOI: 10.1016/j.jtemb.2019.02.013] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Revised: 02/18/2019] [Accepted: 02/27/2019] [Indexed: 12/12/2022]
Abstract
BACKGROUND Joint replacement implants are usually manufactured from cobalt-chromium or titanium alloys. After the device is implanted, wear and corrosion generate metal particles and ions, which are released into local tissue and blood. The metal debris can cause a range of adverse local and systemic effects in patients. RESEARCH PROBLEM In the case of cobalt and chromium, a blood level exceeding 7 μg L-1 indicates potential for local toxicity, and a failing implant. It has been repeatedly suggested in the literature that measurement of titanium could also be used to assess implant function. Despite an increasing interest in this biomarker, and growing use of titanium in orthopaedics, it is unclear what blood concentrations should raise concerns. This is partly due to the technical challenges involved in the measurement of titanium in biological samples. AIM This Review summarises blood/serum titanium levels associated with well-functioning and malfunctioning prostheses, so that the prospects of using titanium measurements to gain insights into implant performance can be evaluated. CONCLUSION Due to inter-laboratory analytical differences, reliable conclusions regarding "normal" and "abnormal" titanium levels in patients with orthopaedic implants are difficult to draw. Diagnosis of symptomatic patients should be based on radiographic evidence combined with blood/serum metal levels.
Collapse
Affiliation(s)
- Ilona Swiatkowska
- Institute of Orthopaedics and Musculoskeletal Science, University College London, HA7 4LP, Stanmore, UK.
| | - Nicholas Martin
- Trace Element Laboratory, Clinical Biochemistry, Charing Cross Hospital, W6 8RF, London, UK
| | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London, HA7 4LP, Stanmore, UK; Royal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK
| |
Collapse
|
23
|
Studies on the titanium dioxide nanoparticles: biosynthesis, applications and remediation. SN APPLIED SCIENCES 2019. [DOI: 10.1007/s42452-019-0337-3] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
|
24
|
Zhou X, Fu X, Chen H, Xiao Z, Min L, Zhou Y, Zhu X, Zhang K, Tu C, Zhang X. Evaluation and regulation of the corrosion resistance of macroporous titanium scaffolds with bioactive surface films for biomedical applications. J Mater Chem B 2019. [DOI: 10.1039/c8tb03359e] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
A three-layer bioactive film on porous titanium was constructed and evaluated for its corrosion resistance via electrochemical analysis.
Collapse
Affiliation(s)
- Xingyu Zhou
- National Engineering Research Center for Biomaterials
- Sichuan University
- Chengdu 610064
- China
| | - Xi Fu
- National Engineering Research Center for Biomaterials
- Sichuan University
- Chengdu 610064
- China
| | - Hongjie Chen
- National Engineering Research Center for Biomaterials
- Sichuan University
- Chengdu 610064
- China
| | - Zhanwen Xiao
- National Engineering Research Center for Biomaterials
- Sichuan University
- Chengdu 610064
- China
| | - Li Min
- Department of Orthopaedics
- West China Hospital of Sichuan University
- Chengdu 610041
- China
| | - Yong Zhou
- Department of Orthopaedics
- West China Hospital of Sichuan University
- Chengdu 610041
- China
| | - Xiangdong Zhu
- National Engineering Research Center for Biomaterials
- Sichuan University
- Chengdu 610064
- China
| | - Kai Zhang
- National Engineering Research Center for Biomaterials
- Sichuan University
- Chengdu 610064
- China
| | - Chongqi Tu
- Department of Orthopaedics
- West China Hospital of Sichuan University
- Chengdu 610041
- China
| | - Xingdong Zhang
- National Engineering Research Center for Biomaterials
- Sichuan University
- Chengdu 610064
- China
| |
Collapse
|
25
|
Mercuri LG, Miloro M, Skipor AK, Bijukumar D, Sukotjo C, Mathew MT. Serum Metal Levels in Maxillofacial Reconstructive Surgery Patients: A Pilot Study. J Oral Maxillofac Surg 2018; 76:2074-2080. [DOI: 10.1016/j.joms.2018.04.014] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2018] [Revised: 04/16/2018] [Accepted: 04/16/2018] [Indexed: 10/17/2022]
|
26
|
Ali I, Suhail M, Alothman ZA, Alwarthan A. Recent advances in syntheses, properties and applications of TiO 2 nanostructures. RSC Adv 2018; 8:30125-30147. [PMID: 35546837 PMCID: PMC9085470 DOI: 10.1039/c8ra06517a] [Citation(s) in RCA: 72] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Accepted: 08/20/2018] [Indexed: 12/21/2022] Open
Abstract
TiO2 is a compound of great importance due to its remarkable catalytic and distinctive semiconducting properties. It is also a chemically stable, non-toxic and biocompatible material. Nano TiO2 is strong oxidizing agent with a large surface area and, hence, high photo-catalytic activities. With low production cost and a high dielectric constant, it is an inexpensive material. It can be prepared by diverse procedures such as solution and gas phase procedures. Nowadays, TiO2 is being used frequently for photo degradation of organic molecules and water splitting for hydrogen generation. Most important applications include purification, disinfection of waste water, self-cleaning coatings for buildings in urban areas and the production of the green currency of energy (hydrogen) by splitting water. The review describes the advances in the syntheses, properties and applications of TiO2 nano structures. Besides, efforts are also made to discuss the working mechanism and future challenges and perspectives.
Collapse
Affiliation(s)
- Imran Ali
- Department of Chemistry, College of Sciences, Taibah University Al-Medina Al-Munawara - 41477 Saudi Arabia
- Department of Chemistry, Jamia Millia Islamia, Central University New Delhi India
| | - Mohd Suhail
- Department of Chemistry, Jamia Millia Islamia, Central University New Delhi India
| | - Zied A Alothman
- Department of Chemistry, College of Science, King Saud University Riyadh 11451 Kingdom of Saudi Arabia
| | - Abdulrahman Alwarthan
- Department of Chemistry, College of Science, King Saud University Riyadh 11451 Kingdom of Saudi Arabia
| |
Collapse
|
27
|
Brayda-Bruno M, Fini M, Pierini G, Giavaresi G, Rocca M, Giardino R. Evaluation of Systemic Metal Diffusion after Spinal Pedicular Fixation with Titanium Alloy and Stainless Steel System: A 36-month Experimental Study in Sheep. Int J Artif Organs 2018. [DOI: 10.1177/039139880102400108] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
It is known that titanium alloys cause more extensive local metallosis due to fretting corrosion than stainless steel implants. The aim of the present study was to investigate possible systemic metal releases (Ti, Al, V, Cr, Ni) in sheep where L4–L5 were implanted with titanium alloy (Ti6Al4V, ASTM F 136) and stainless steel (AISI 316 L). 16 sheep were used: 8 were implanted with Ti6Al4V and 8 with stainless steel. At 6, 12, 24 and 36 months, the following examinations were performed: histology, atomic absorption spectrophotometry (AAS) and scanning electron microscopy (SEM), on liver, lung, kidney, brain, spleen and lumbo-aortic lymph nodes. Hair, urine and arteria blood samples were also analysed by AAS before implantation and at sacrifices. A histologic and ultrastructural study was performed on peri-implant tissues, too. Particular attention was paid to avoid contamination from dissection instruments or use of containers. In basal and in samples at 6 and 12 months, no metals were found in blood, urine, hair or other target tissues of the animals implanted with either Ti6Al4V or stainless steel. Regarding Al, V, Co and Ni, negative results in all tissues and body fluids were obtained also at 24 and 36 months. On the contrary, Ti traces were found in lumbo-aortic lymph nodes and lungs of one sheep only (10 and 30 ng/g, respectively) at 24 months. At 36 months, a systemic diffusion of Ti was observed in all tissues of both sheep instrumented with Ti6AI4V (2-16.5 ng/g), except for body fluids and hair. Metal research in target tissues by light and SEM micro-probe analysis provided negative results. Current data suggest that the amount of Ti found in organs after stable pedicular fixation is extremely low and not biologically available. This observation would lead us to exclude the hypothesis of any toxic reaction and such a release seems to be due to the passive diffusion through lymphatic fluids. Additional studies are needed to confirm if this long-term release of Ti particles might cause tissue damage.
Collapse
Affiliation(s)
- M. Brayda-Bruno
- Centre for Spinal Diseases, San Donato Hospital Group-Galeazzi Institute, Milan - Italy
| | - M. Fini
- Experimental Surgery Department, Research Institute Codivilla Putti, Rizzoli Orthopaedic Institute, Bologna - Italy
| | - G. Pierini
- Forensic Medicine Department, University of Bologna - Italy
| | - G. Giavaresi
- Experimental Surgery Department, Research Institute Codivilla Putti, Rizzoli Orthopaedic Institute, Bologna - Italy
| | - M. Rocca
- Experimental Surgery Department, Research Institute Codivilla Putti, Rizzoli Orthopaedic Institute, Bologna - Italy
| | - R. Giardino
- Experimental Surgery Department, Research Institute Codivilla Putti, Rizzoli Orthopaedic Institute, Bologna - Italy
- Chair of Surgical Pathophysiology, University of Bologna - Italy
| |
Collapse
|
28
|
Pierini G, Fini M, Giavaresi G, Dallari S, Brayda Bruno M, Rocca M, Nicoli Aldini N, Giardino R. Atomic Absorption Spectrophotometry (AAS) for the Evaluation of Metallosis in Prostheses and Artificial Organs: A New Approach. Int J Artif Organs 2018. [DOI: 10.1177/039139889902200712] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
To study the presence of metals in body fluids and tissues after implantation of metallic biomaterials and possible related diseases, a new approach in Atomic Absorption Spectrophotometry (AAS) was developed. This technique was compared to three traditional methods: mineralisation with acid digestion (method A) also known as “wet method”, dry ashing (with or without oxygen) (method B); classic Kjeldaal (method C). The new approach (method D) modifies the mineralisation phase and the instrument operating instructions. Al, Na, Cr, K, Ni, Co, Ti, Fe, Hg, Pb, V, Sb and Cu levels were tested with the four methods on bone, muscle, cartilage, skin, brain, lymph nodes, blood, urine, and hair. Test results were checked by the addition method. Results demonstrated a significantly higher percentage of Al, Cr, Ni, Ti and Hg recovery with the new approach. The advantages of method D are no residue, no redox reaction, insignificant loss of analytes and enhanced sensitivity (at ppb level vs ppm of the other methods). This approach should be considered especially when testing heavy metals and complex matrices. Its disadvantages are that it is more time consuming and requires the presence of an operator.
Collapse
Affiliation(s)
- G. Pierini
- Forensic Medicine Department, University of Bologna, Bologna
| | - M. Fini
- Experimental Surgery, Research Institute Codivilla-Putti, Rizzoli Orthopaedic Institutes, Bologna
| | - G. Giavaresi
- Experimental Surgery, Research Institute Codivilla-Putti, Rizzoli Orthopaedic Institutes, Bologna
| | - S. Dallari
- Forensic Medicine Department, University of Bologna, Bologna
| | | | - M. Rocca
- Experimental Surgery, Research Institute Codivilla-Putti, Rizzoli Orthopaedic Institutes, Bologna
| | - N. Nicoli Aldini
- Experimental Surgery, Research Institute Codivilla-Putti, Rizzoli Orthopaedic Institutes, Bologna
| | - R. Giardino
- Experimental Surgery, Research Institute Codivilla-Putti, Rizzoli Orthopaedic Institutes, Bologna
- Surgical Pathophysiology, Medical School, University of Bologna, Bologna - Italy
| |
Collapse
|
29
|
Fillingham YA, Della Valle CJ, Bohl DD, Kelly MP, Hall DJ, Pourzal R, Jacobs JJ. Serum Metal Levels for Diagnosis of Adverse Local Tissue Reactions Secondary to Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty. J Arthroplasty 2017; 32:S272-S277. [PMID: 28511949 DOI: 10.1016/j.arth.2017.04.016] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 03/28/2017] [Accepted: 04/10/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Recently, corrosion at the head-neck junction in metal-on-polyethylene bearing surface total hip arthroplasty (THA) has been recognized as a cause of adverse local tissue reactions (ALTRs). Serum metal levels have been advocated as a tool for the diagnosis of ALTR; however, no prior studies have specifically examined their utility. The purpose of this study was to determine the optimal cutoff values for serum cobalt and chromium levels in diagnosing ALTR after metal-on-polyethylene bearing surface THA. METHODS We reviewed 447 consecutive patients with serum metal levels tested at our institution and identified 64 patients with a metal-on-polyethylene bearing who had axial imaging or underwent reoperation to confirm the presence or absence of ALTR. Receiver-operating characteristic curves were produced to identify cutoff thresholds to optimize sensitivity, and diagnostic test performance was characterized. RESULTS Forty-four of the 64 patients (69%) were positive for an ALTR. The best test for the diagnosis of ALTR was the serum cobalt level (area under the curve [AUC] = 99%). A threshold cutoff of ≥1.0 ng/mL had a sensitivity of 100%, specificity of 90%, positive predictive value (PPV) of 96%, and negative predictive value (NPV) of 100%. Serum chromium levels were also diagnostic (AUC = 87%). A threshold cutoff of ≥0.15 ng/mL had a sensitivity of 100%, specificity of 50%, PPV of 81%, and NPV of 100%. Finally, serum cobalt-to-chromium ratio was also helpful for diagnosis (AUC = 90%). A threshold cutoff value of 1.4 for the cobalt-to-chromium ratio offered a sensitivity of 93%, specificity of 70%, PPV of 87%, and NPV of 82%. CONCLUSION Measurement of serum cobalt level with a threshold value of 1.0 ng/mL in our experience is the best test for identifying the presence of ALTR in patients with a metal-on-polyethylene THA. Measurement of chromium level and the ratio of cobalt-to-chromium levels are also of value.
Collapse
Affiliation(s)
- Yale A Fillingham
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Craig J Della Valle
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Daniel D Bohl
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Mick P Kelly
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Deborah J Hall
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Robin Pourzal
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Joshua J Jacobs
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| |
Collapse
|
30
|
Tasat DR, Domingo MG, Bruno ME, Guglielmotti MB, Olmedo DG. Titanium Nanoparticle Size Influences Trace Concentration Levels in Skin Appendages. Toxicol Pathol 2017; 45:624-632. [DOI: 10.1177/0192623317711808] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
As a result of biotribocorrosion, the surface of a titanium (Ti) biomedical device can be a potential source of systemic contamination with Ti nanoparticles (NPs). Although NPs can be chemically similar, differences in particle size may lead to different biological responses. The aim of this experimental study was to determine Ti trace levels in skin appendages and plasma and explore the influence of NP size on trace levels using a murine model. Results showed the presence of Ti traces in the nails, hair, and plasma. The concentration of the smallest NPs (5 Nm) was higher than that of 10 Nm NPs in all the studied samples. Irrespective of NP size, Ti levels were always lower in plasma than in skin appendages. Ti levels were higher in nails than in hair. Ti NPs size influenced trace concentration levels in hair/nails, suggesting that 5 Nm Ti particles are more easily eliminated through these skin appendages. Given that the nails showed the highest levels of Ti, and that these skin appendages are not exposed to agents that can leach out Ti, as occurs with hair, we propose the nails as the most suitable and reliable bioindicator for monitoring systemic contamination with Ti.
Collapse
Affiliation(s)
- Deborah R. Tasat
- School of Science and Technology, National University of General San Martín, San Martín, Buenos Aires, Argentina
- Department of Histology and Embryology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina
| | - Mariela G. Domingo
- Department of Oral Pathology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina
| | - Marcos E. Bruno
- Department of Oral Pathology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina
| | - María B. Guglielmotti
- Department of Oral Pathology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina
- National Research Council (CONICET), Buenos Aires, Argentina
| | - Daniel G. Olmedo
- Department of Oral Pathology, School of Dentistry, University of Buenos Aires, Buenos Aires, Argentina
- National Research Council (CONICET), Buenos Aires, Argentina
| |
Collapse
|
31
|
Shi H, Gu Y, Xie Z, Zhou Q, Mao G, Lin X, Liu K, Liu Y, Zou B, Zhao J. Mechanism of N-acetyl-cysteine inhibition on the cytotoxicity induced by titanium dioxide nanoparticles in JB6 cells transfected with activator protein-1. Exp Ther Med 2017; 13:3549-3554. [PMID: 28588678 PMCID: PMC5450798 DOI: 10.3892/etm.2017.4415] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2015] [Accepted: 01/26/2016] [Indexed: 11/20/2022] Open
Abstract
The present study investigated the mechanism of N-acetyl-cysteine (NAC) inhibition on the cytotoxicity induced by titanium dioxide (TiO2) nanoparticles (NPs) using murine epidermal JB6 cells transfected with activator protein-1 (AP-1), JB6-AP-1 cells. Confocal microscopy was performed to localize TiO2 NPs in cultured cells. The level of reactive oxygen species (ROS) present in cells was evaluated by staining with 2′,7′-dichlorodihydrofluorescein diacetate and dihydroethidium. AP-1 gene expression levels in the cells were detected using the luciferase assay. Confocal microscopy indicated that TiO2 NPs passed through the cell membrane into the cytoplasm; however, they did not penetrate the nuclear membrane. The present findings indicated that NAC markedly inhibited ROS generation and significantly inhibited cytotoxicity (P<0.05) induced by TiO2 NPs. Furthermore, alternative studies have demonstrated that AP-1 luciferase activity induced by TiO2 NPs may be significantly inhibited by NAC. In conclusion, the ability for NAC to inhibit the cytotoxicity induced by TiO2 NPs may primarily occur by blocking ROS generation in the cultured cells.
Collapse
Affiliation(s)
- Hongbo Shi
- Public Health Department of Medical School, Zhejiang Provincial Key Laboratory of Pathological and Physiological Technology, Ningbo University, Ningbo, Zhejiang 315211, P.R. China.,Ningbo Municipal Center for Disease Control and Prevention, Ningbo, Zhejiang 315010, P.R. China
| | - Yuanliang Gu
- Public Health Department of Medical School, Zhejiang Provincial Key Laboratory of Pathological and Physiological Technology, Ningbo University, Ningbo, Zhejiang 315211, P.R. China
| | - Zhenhua Xie
- Department of Urology, Ningbo Yinzhou No. 2 Hospital, Ningbo, Zhejiang 315100, P.R. China
| | - Qi Zhou
- Public Health Department of Medical School, Zhejiang Provincial Key Laboratory of Pathological and Physiological Technology, Ningbo University, Ningbo, Zhejiang 315211, P.R. China
| | - Guochuan Mao
- Public Health Department of Medical School, Zhejiang Provincial Key Laboratory of Pathological and Physiological Technology, Ningbo University, Ningbo, Zhejiang 315211, P.R. China.,Ningbo Municipal Center for Disease Control and Prevention, Ningbo, Zhejiang 315010, P.R. China
| | - Xialu Lin
- Public Health Department of Medical School, Zhejiang Provincial Key Laboratory of Pathological and Physiological Technology, Ningbo University, Ningbo, Zhejiang 315211, P.R. China
| | - Kui Liu
- Public Health Department of Medical School, Zhejiang Provincial Key Laboratory of Pathological and Physiological Technology, Ningbo University, Ningbo, Zhejiang 315211, P.R. China
| | - Yu Liu
- Public Health Department of Medical School, Zhejiang Provincial Key Laboratory of Pathological and Physiological Technology, Ningbo University, Ningbo, Zhejiang 315211, P.R. China
| | - Baobo Zou
- Public Health Department of Medical School, Zhejiang Provincial Key Laboratory of Pathological and Physiological Technology, Ningbo University, Ningbo, Zhejiang 315211, P.R. China
| | - Jinshun Zhao
- Public Health Department of Medical School, Zhejiang Provincial Key Laboratory of Pathological and Physiological Technology, Ningbo University, Ningbo, Zhejiang 315211, P.R. China
| |
Collapse
|
32
|
Nam D, Salih R, Brown KM, Nunley RM, Barrack RL. Metal Ion Levels in Young, Active Patients Receiving a Modular, Dual Mobility Total Hip Arthroplasty. J Arthroplasty 2017; 32:1581-1585. [PMID: 28057394 DOI: 10.1016/j.arth.2016.12.012] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2016] [Revised: 11/23/2016] [Accepted: 12/10/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Dual mobility total hip arthroplasty (THA) components improve stability, yet use of a modular cobalt alloy acetabular liner may be associated with metal ion release. This study's purpose was to measure blood metal ion levels in young, active patients receiving a dual mobility THA prosthesis. METHODS This is a prospective study of young, active patients undergoing primary THA. Twenty-six patients received a 22-mm cobalt alloy (n = 10) or a 28-mm ceramic (n = 16) femoral head, a modular cobalt chrome acetabular liner, with a highly cross-linked polyethylene insert (dual mobility). Seventeen control patients received a 32-mm cobalt alloy (n = 6), oxidized zirconium (n = 5), or ceramic (n = 6) femoral head and polyethylene acetabular liner (conventional). All patients received a cementless, titanium femoral stem. Blood metal ion levels (μg/L) were measured preoperatively and at 1 year postoperatively. RESULTS No difference was present for age or body mass index (P = .5 and .9). At 1 year postoperatively, mean cobalt levels were greater in the dual mobility cohort (0.23 ± 0.39 vs 0.15 ± 0.07, P < .001). Four patients in the dual mobility cohort had a cobalt level outside the reference range (0.03-0.29), with values from 0.34 to 1.81 μg/L. One patient in the conventional cohort had a cobalt level outside the reference range with a value of 0.39 μg/L. CONCLUSION The presence and clinical significance of increased cobalt levels in 4 patients with the use of a modular dual mobility prosthesis demonstrates the necessity of continued surveillance.
Collapse
Affiliation(s)
- Denis Nam
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Rondek Salih
- Department of Orthopedic Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St. Louis, Missouri
| | - Katherine M Brown
- Department of Orthopedic Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St. Louis, Missouri
| | - Ryan M Nunley
- Department of Orthopedic Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St. Louis, Missouri
| | - Robert L Barrack
- Department of Orthopedic Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St. Louis, Missouri
| |
Collapse
|
33
|
Gnedenkov SV, Sinebryukhov SL, Puz AV, Egorkin VS, Kostiv RE. In vivo study of osteogenerating properties of calcium-phosphate coating on titanium alloy Ti-6Al-4V. Biomed Mater Eng 2017; 27:551-560. [PMID: 28234240 DOI: 10.3233/bme-161608] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The method of formation of bioactive calcium-phosphate coating on medical titanium alloy Ti-6Al-4V (3.5-5.3% V; 5.3-6.8% Al; balance -Ti) by plasma electrolytic oxidation (PEO) has been developed. Evaluation of osteogenerating properties of the coating at fractures of the shaft of the femur on Wistar line laboratory rats has been performed. It has been established that the calcium-phosphate PEO coating accelerates osteogenesis and promotes the formation of a pronounced periosteal callus in the fracture area. The presence of calcium phosphates in the PEO coating surface layer significantly accelerates the growth of bone tissue on the titanium surface.
Collapse
Affiliation(s)
- Sergey V Gnedenkov
- Institute of Chemistry, Far Eastern Branch of the Russian Academy of Sciences, 159, Prosp. 100-letiya Vladivostoka, Vladivostok 690022, Russia
| | - Sergey L Sinebryukhov
- Institute of Chemistry, Far Eastern Branch of the Russian Academy of Sciences, 159, Prosp. 100-letiya Vladivostoka, Vladivostok 690022, Russia
| | - Artyom V Puz
- Institute of Chemistry, Far Eastern Branch of the Russian Academy of Sciences, 159, Prosp. 100-letiya Vladivostoka, Vladivostok 690022, Russia
| | - Vladimir S Egorkin
- Institute of Chemistry, Far Eastern Branch of the Russian Academy of Sciences, 159, Prosp. 100-letiya Vladivostoka, Vladivostok 690022, Russia
| | - Roman E Kostiv
- Pacific State Medical University, 2, Prosp. Ostryakova, Vladivostok, Russia
| |
Collapse
|
34
|
Serum Metal Concentrations in Patients With Titanium Ceramic Composite Cervical Disc Replacements. Spine (Phila Pa 1976) 2017; 42:366-371. [PMID: 27323223 DOI: 10.1097/brs.0000000000001745] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Prospective longitudinal study. OBJECTIVE The serum titanium (Ti) concentrations were examined in patients implanted with a PRESTIGE LP Cervical Disc System (Medtronic, Inc., Memphis, TN). The metal-on-metal disc with ball-in-trough articulation is made of titanium alloy/titanium carbide composite (Ti-6Al-4 V/TiC). SUMMARY OF BACKGROUND DATA Cervical disc arthroplasty provides a motion-preserving treatment alternative to anterior cervical discectomy and fusion for degenerative cervical disc disease. The articulating surfaces have a tendency to generate in vivo wear in the form of insoluble particulates (debris) and soluble metal ions. Not much information is available on the long-term metal concentrations observed in cervical disc arthroplasty and how these compare with the metal concentrations in Ti-based posterior fixation devices and other joint replacement implants. METHODS Thirty patients were enrolled after strict exclusion criteria that included no previous permanent metal implants and no professional exposure to metal particles. High-resolution inductively coupled plasma-mass spectrometry was used to assay blood serum titanium concentrations preoperatively and at 3, 6, 12, 24, 36, 60, and 84 months after surgery. The detection limit for Ti was 0.2 ng/mL. The Friedman test was used to make longitudinal statistical comparisons. RESULTS The median serum Ti concentrations determined preoperatively, and at 3, 6, 12, 24, 36, 60, and 84 months were 0.10, 1.22, 1.15, 1.27, 1.21, 1.46, 1.34, and 1.42 ng/mL, respectively. The serum Ti concentrations at all postoperative time points were significantly higher than that at the preoperative time point (Friedman P < 0.01). CONCLUSION The long-term postoperative serum Ti concentrations were significantly higher than the preoperative concentrations. The observed serum Ti concentrations in this study are lower than the reported concentrations in patients receiving posterior spinal instrumentation and metal or ceramic-on-polyethylene hip prostheses with Ti-alloy based stems and acetabular components. LEVEL OF EVIDENCE 3.
Collapse
|
35
|
Saleh MM, Touny AH, Al-Omair MA, Saleh MM. Biodegradable/biocompatible coated metal implants for orthopedic applications. Biomed Mater Eng 2017; 27:87-99. [PMID: 27175470 DOI: 10.3233/bme-161568] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Biocompatible metals have been suggested as revolutionary biomaterials for bone-grafting therapies. Although metals and their alloys are widely and successfully used in producing biomedical implants due to their good mechanical properties and corrosion resistance, they have a lack in bioactivity. Therefore coating of the metal surface with calcium phosphates (CaP) is a benign way to achieve well bioactivity and get controlled corrosion properties. The biocompatibility and bioactivity calcium phosphates (CaP) in bone growth were guided them to biomedical treatment of bone defects and fractures. Many techniques have been used for fabrication of CaP coatings on metal substrates such as magnesium and titanium. The present review will focus on the synthesis of CaP and their relative forms using different techniques especially electrochemical techniques. The latter has always been known of its unique way of optimizing the process parameters that led to a control in the structure and characteristics of the produced materials.
Collapse
Affiliation(s)
- Mohamed M Saleh
- Kasr Al-Ainy School of Medicine, Cairo University, Cairo, Egypt
| | - A H Touny
- Department of Chemistry, Faculty of Science, Helwan University, Helwan, Cairo, Egypt.,Chemistry Department, College of Science, King Faisal University, Al-Hassa, Saudi Arabia
| | - Mohammed A Al-Omair
- Chemistry Department, College of Science, King Faisal University, Al-Hassa, Saudi Arabia
| | - M M Saleh
- Department of Chemistry, Faculty of Science, Cairo University, Cairo, Egypt.,Chemistry Department, College of Science, King Faisal University, Al-Hassa, Saudi Arabia
| |
Collapse
|
36
|
Zhang D, Wong CS, Wen C, Li Y. Cellular responses of osteoblast-like cells to 17 elemental metals. J Biomed Mater Res A 2016; 105:148-158. [PMID: 27601355 DOI: 10.1002/jbm.a.35895] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Revised: 08/29/2016] [Accepted: 09/02/2016] [Indexed: 11/06/2022]
Abstract
Elemental metals have been widely used to alloy metallic orthopedic implants. However, there is still insufficient research data elucidating the cell responses of osteoblastic cells to alloying elemental metals, which impedes the development of new metallic implant materials. In this study, the cellular responses of osteoblast-like cells (SaOS2) to 17 pure alloying elemental metals, that is, titanium (Ti), zirconium (Zr), hafnium (Hf), vanadium (V), niobium (Nb), tantalum (Ta), chromium (Cr), molybdenum (Mo), manganese (Mn), iron (Fe), ruthenium (Ru), cobalt (Co), nickel (Ni), copper (Cu), zinc (Zn), silicon (Si), and tin (Sn) were comparatively investigated in vitro. Cellular responses including intracellular total protein synthesis and collagen content, cell adhesion, cell proliferation, and alkaline phosphatase (ALP) activity on these elemental metals were systematically assessed and compared. It was found that these elemental metals could be categorized into three groups based on the cellular functions on them. Group 1, including Ti, Zr, Hf, Nb, Ta, Cr, Ru, and Si, showed excellent cell proliferation and varied ALP activity for SaOS2 cells. Cells exposed to Group 2, including Mo and Sn, although initially attached and grew, did not proliferate over time. In contrast, Group 3, including V, Mn, Fe, Co, Ni, Cu, and Zn, showed severe cytotoxicity toward SaOS2 cells. It is vital to consider the cell responses to the elemental metals when designing a new metallic implant material and the findings of this study provide insights into the biological performance of the elemental metals. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 148-158, 2017.
Collapse
Affiliation(s)
- Dongmei Zhang
- Institute for Frontier Materials, Deakin University, Geelong, Victoria, 3217, Australia
| | - Cynthia S Wong
- Institute for Frontier Materials, Deakin University, Geelong, Victoria, 3217, Australia
| | - Cuie Wen
- School of Engineering, RMIT University, Melbourne, Victoria, 3001, Australia
| | - Yuncang Li
- School of Engineering, RMIT University, Melbourne, Victoria, 3001, Australia
| |
Collapse
|
37
|
Fage SW, Muris J, Jakobsen SS, Thyssen JP. Titanium: a review on exposure, release, penetration, allergy, epidemiology, and clinical reactivity. Contact Dermatitis 2016; 74:323-45. [PMID: 27027398 DOI: 10.1111/cod.12565] [Citation(s) in RCA: 141] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2015] [Revised: 02/07/2016] [Accepted: 02/08/2016] [Indexed: 11/29/2022]
Abstract
Exposure to titanium (Ti) from implants and from personal care products as nanoparticles (NPs) is common. This article reviews exposure sources, ion release, skin penetration, allergenic effects, and diagnostic possibilities. We conclude that human exposure to Ti mainly derives from dental and medical implants, personal care products, and foods. Despite being considered to be highly biocompatible relative to other metals, Ti is released in the presence of biological fluids and tissue, especially under certain circumstances, which seem to be more likely with regard to dental implants. Although most of the studies reviewed have important limitations, Ti seems not to penetrate a competent skin barrier, either as pure Ti, alloy, or as Ti oxide NPs. However, there are some indications of Ti penetration through the oral mucosa. We conclude that patch testing with the available Ti preparations for detection of type IV hypersensitivity is currently inadequate for Ti. Although several other methods for contact allergy detection have been suggested, including lymphocyte stimulation tests, none has yet been generally accepted, and the diagnosis of Ti allergy is therefore still based primarily on clinical evaluation. Reports on clinical allergy and adverse events have rarely been published. Whether this is because of unawareness of possible adverse reactions to this specific metal, difficulties in detection methods, or the metal actually being relatively safe to use, is still unresolved.
Collapse
Affiliation(s)
- Simon W Fage
- Department of Dermato-Venereology, Aarhus University Hospital, 8000 Aarhus, Denmark
| | - Joris Muris
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam, University of Amsterdam and VU University Amsterdam, Gustav Mahlerlaan 3004, 1081 LA, Amsterdam, The Netherlands
| | - Stig S Jakobsen
- Department of Orthopaedic Surgery, Aarhus University Hospital, 8000 Aarhus, Denmark
| | - Jacob P Thyssen
- National Allergy Research Centre, Department of Dermato-Allergology, Copenhagen University Hospital Herlev-Gentofte, 2900 Hellerup, Denmark
| |
Collapse
|
38
|
Metal concentrations in the blood and tissues after implantation of titanium growth guidance sliding instrumentation. Spine J 2016; 16:380-8. [PMID: 26656164 DOI: 10.1016/j.spinee.2015.11.040] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2015] [Revised: 08/07/2015] [Accepted: 11/18/2015] [Indexed: 02/03/2023]
Abstract
BACKGROUND Growth guidance sliding treatment devices, such as Shilla (Medtronic, Minneapolis, MN USA) or LSZ-4D (CONMET, Moscow, Russia), used for the treatment of scoliosis in children who have high growth potential have unlocked fixtures that allow rods to slide during growth of the spine, which avoids periodical extensions. However, the probability of clinical complications associated with metallosis after implantation of such devices is poorly understood. The content of metal ions in the blood and tissues of pediatric patients treated for scoliosis using fusionless growth guidance sliding instrumentation has not yet been investigated. PURPOSE The aim of the present study was to measure the content of metal ions in the blood and tissues surrounding the implanted growth guidance sliding LSZ-4D devices made of titanium alloy (Ti6Al4V), and to identify the incidence of metallosis-associated clinical complications in some patients with these devices. STUDY DESIGN This is a one-center, case-control retrospective study. PATIENTS SAMPLE The study group included 25 patients with high growth potential (22 females, 3 males; average age at primary surgery for scoliosis treatment is 11.4±1.2 years old) who had sliding growth guidance instrumentation LSZ-4D (CONMET) implanted on 13 (range: 10-16) spine levels for 6±2 years. The LSZ-4D device was made from titanium alloy Ti6Al4V and consisted of two rectangular section rods and fixture elements. Locked fixtures were used on one spinal level, whereas the others were unlocked (sliding). The control group consisted of 13 patients (12 females and 1 male; 11±1.2 years old) without any implanted devices. OUTCOME MEASURES The content of Ti, Al, and V metal ions in the whole blood and tissues around the implanted device was measured. The incidences of metallosis-associated complications in the study group were recorded. METHODS Metal ion content was measured by the inductively coupled mass spectrometry method on quadrupolar NexION 300D (PerkinElmer Inc, Shelton, CT, USA). RESULTS Five of 25 patients in the study group developed metallosis-associated complications (two sinuses and three seroma in the lumbar part of the spine). Revisions were carried out in two of these patients. Ninety percent of the patients in the study group had increased content of Ti and V ions in the blood (2.8 and 4 times, respectively). Median content of Ti ions in soft tissues adjacentto implanted sliding device was more than 1,500-fold higher than that of the control group. These levels are much higher than previously reported for spinal instrumentation. CONCLUSIONS Increased content of Ti and V ions in the blood and especially in tissues around the titanium growth guidance sliding device LSZ-4D accompanied by clinical manifestations (seroma and sinuses) indicates the importance of improving wear resistance of such instrumentation with the coatings and the necessity to exchange sliding instrumentation once the child is fully grown.
Collapse
|
39
|
Kim J, Gilbert JL. Cytotoxic effect of galvanically coupled magnesium-titanium particles. Acta Biomater 2016; 30:368-377. [PMID: 26596564 DOI: 10.1016/j.actbio.2015.11.030] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2015] [Revised: 10/14/2015] [Accepted: 11/16/2015] [Indexed: 01/20/2023]
Abstract
Recent work has shown that reduction reactions at metallic biomaterial surfaces can induce significant killing of cells in proximity to the surface. To exploit this phenomenon for therapeutic purposes, for example, for cancer tumor killing or antibacterial effects (amongst other applications), magnesium metal particles, galvanically coupled to titanium by sputtering, have been evaluated for their cell-killing capability (i.e. cytotoxicity). Magnesium (Mg) particles large enough to prevent particle phagocytosis were investigated, so that only electrochemical reactions, and not particle toxicity per se, caused cytotoxic effects. Titanium (Ti) coated magnesium particles, as well as magnesium-only particles were introduced into MC3T3-E1 mouse pre-osteoblast cell cultures over a range of particle concentrations, and cells were observed to die in a dosage-dependent manner. Ti-coated magnesium particles killed more cells at lower particle concentration than magnesium alone (P<0.05), although the pH measured for magnesium and magnesium-titanium had no significant difference at similar particle concentrations. Complete cell killing occurred at 750μg/ml and 1500μg/ml for Mg-Ti and Mg, respectively. Thus, this work demonstrates that galvanically coupled Mg-Ti particles have a significant cell killing capability greater than Mg alone. In addition, when the pH associated with complete killing with particles was created using NaOH only (no particles), then the percentage of cells killed was significantly less (P<0.05). Together, these findings show that pH is not the sole factor associated with cell killing and that the electrochemical reactions, including the reduction reactions, play an important role. Reduction reactions on galvanically coupled Mg-Ti and Mg particles may generate reactive oxygen intermediates that are able to kill cells in close proximity to the particles and this approach may lead to potential therapies for infection and cancer. STATEMENT OF SIGNIFICANCE This paper demonstrates that during active corrosion of both Mg and Mg-Ti particles cells cultured with the particles are killed in a dose-dependent particle concentration fashion. Additionally, galvanically-coupled magnesium-titanium microparticles kill cells more effectively than magnesium particles alone. The killing effect was shown to not be due to pH shifts since no differences were seen for different particle types and pH adjusted medium without particles did not exhibit the same level of killing. The significance of this work is the recognition of this killing effect with Mg particles and the potential therapeutic applications in infection control and cancer treatment that this process may provide.
Collapse
|
40
|
Nam D, Keeney JA, Nunley RM, Johnson SR, Clohisy JC, Barrack RL. Metal Ion Concentrations in Young, Active Patients Following Total Hip Arthroplasty with the Use of Modern Bearing Couples. J Arthroplasty 2015; 30:2227-32. [PMID: 26164561 DOI: 10.1016/j.arth.2015.06.025] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2015] [Revised: 06/04/2015] [Accepted: 06/15/2015] [Indexed: 02/01/2023] Open
Abstract
The purpose of this study was to compare whole blood metal ion levels in young, active patients undergoing primary total hip arthroplasty with the use of a cobalt-alloy (ten patients), ceramic (15 patients), or oxinium (11 patients) femoral head and highly crosslinked polyethylene acetabular liner. At 2 years postoperatively, mean cobalt concentrations were 3.0 times higher in the cobalt-alloy cohort versus the ceramic cohort, and 2.3 times higher versus the oxinium cohort (P=0.3-0.5). Titanium levels were consistently elevated at all postoperative time points versus preoperatively in all cohorts. Young, active patients following THA demonstrate elevated cobalt and titanium concentrations. Use of a ceramic or oxinium femoral head decreased the degree of cobalt elevation versus a cobalt-alloy femoral head, but did not reach statistical significance.
Collapse
Affiliation(s)
- Denis Nam
- Washington University School of Medicine/Barnes-Jewish Hospital, Department of Orthopedic Surgery, St. Louis, Missouri
| | - James A Keeney
- University of Missouri, Department of Orthopedic Surgery, Columbia, Missouri
| | - Ryan M Nunley
- Washington University School of Medicine/Barnes-Jewish Hospital, Department of Orthopedic Surgery, St. Louis, Missouri
| | - Staci R Johnson
- Washington University School of Medicine/Barnes-Jewish Hospital, Department of Orthopedic Surgery, St. Louis, Missouri
| | - John C Clohisy
- Washington University School of Medicine/Barnes-Jewish Hospital, Department of Orthopedic Surgery, St. Louis, Missouri
| | - Robert L Barrack
- Washington University School of Medicine/Barnes-Jewish Hospital, Department of Orthopedic Surgery, St. Louis, Missouri
| |
Collapse
|
41
|
Guglielmotti MB, Domingo MG, Steimetz T, Ramos E, Paparella ML, Olmedo DG. Migration of titanium dioxide microparticles and nanoparticles through the body and deposition in the gingiva: an experimental study in rats. Eur J Oral Sci 2015; 123:242-8. [DOI: 10.1111/eos.12190] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/03/2015] [Indexed: 01/23/2023]
Affiliation(s)
- María B. Guglielmotti
- Department of Oral Pathology; School of Dentistry; University of Buenos Aires; Buenos Aires Argentina
- National Research Council (CONICET); Buenos Aires Argentina
| | - Mariela G. Domingo
- Department of Oral Pathology; School of Dentistry; University of Buenos Aires; Buenos Aires Argentina
- Research Fellow of the National Inter-university Council (Consejo Interuniversitario Nacional - CIN); Buenos Aires Argentina
| | - Tammy Steimetz
- Department of Oral Pathology; School of Dentistry; University of Buenos Aires; Buenos Aires Argentina
| | - Emilio Ramos
- Department of Oral Pathology; School of Dentistry; University of Buenos Aires; Buenos Aires Argentina
| | - María L. Paparella
- Department of Oral Pathology; School of Dentistry; University of Buenos Aires; Buenos Aires Argentina
| | - Daniel G. Olmedo
- Department of Oral Pathology; School of Dentistry; University of Buenos Aires; Buenos Aires Argentina
- National Research Council (CONICET); Buenos Aires Argentina
| |
Collapse
|
42
|
Sowa M, Piotrowska M, Widziołek M, Dercz G, Tylko G, Gorewoda T, Osyczka AM, Simka W. Bioactivity of coatings formed on Ti–13Nb–13Zr alloy using plasma electrolytic oxidation. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 49:159-173. [DOI: 10.1016/j.msec.2014.12.073] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2014] [Revised: 12/09/2014] [Accepted: 12/20/2014] [Indexed: 01/07/2023]
|
43
|
Osman RB, Swain MV. A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia. MATERIALS 2015; 8:932-958. [PMID: 28787980 PMCID: PMC5455450 DOI: 10.3390/ma8030932] [Citation(s) in RCA: 202] [Impact Index Per Article: 20.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2014] [Revised: 01/20/2015] [Accepted: 02/12/2015] [Indexed: 01/21/2023]
Abstract
The goal of the current publication is to provide a comprehensive literature review on the topic of dental implant materials. The following paper focuses on conventional titanium implants and more recently introduced and increasingly popular zirconia implants. Major subtopics include the material science and the clinical considerations involving both implant materials and the influence of their physical properties on the treatment outcome. Titanium remains the gold standard for the fabrication of oral implants, even though sensitivity does occur, though its clinical relevance is not yet clear. Zirconia implants may prove to be promising in the future; however, further in vitro and well-designed in vivo clinical studies are needed before such a recommendation can be made. Special considerations and technical experience are needed when dealing with zirconia implants to minimize the incidence of mechanical failure.
Collapse
Affiliation(s)
- Reham B Osman
- Department of Oral Implantology and Prosthetic Dentistry, Academic Centrum of Dentistry Amsterdam (ACTA), 1081 LA Amsterdam, The Netherlands.
- Department of Removable Prosthodontics, Cairo University, Giza 11553, Egypt.
| | - Michael V Swain
- Biomaterials Laboratory, Sydney Dental Hospital, the University of Sydney, Surry Hills, NSW 2010, Australia.
| |
Collapse
|
44
|
Local and systemic metal ion release occurs intraoperatively during correction and instrumented spinal fusion for scoliosis. J Child Orthop 2015; 9:39-43. [PMID: 25589286 PMCID: PMC4340846 DOI: 10.1007/s11832-015-0631-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Accepted: 01/03/2015] [Indexed: 02/03/2023] Open
Abstract
STUDY DESIGN Prospective pilot study. OBJECTIVES The aim of this study was to measure titanium, niobium and aluminium levels in various intraoperative and postoperative samples to determine patterns of metal ion release that occur within the first month following instrumented spinal fusion. Raised serum metal ion levels are reported following instrumented spinal fusion in adolescent idiopathic scoliosis. The exact topological origin and chronology of metal ion release remains conjectural. Recent literature suggests an immediate rise in serum metal levels within the first postoperative week. METHODS Titanium, niobium and aluminium levels were measured before, during and after surgery in serum and local intraoperative fluid samples obtained from two pediatric patients undergoing posterior correction and instrumentation for scoliosis. RESULTS Measurable metal ion levels were detected in all local samples obtained from wound irrigation fluid, cell saver blood, and fluid that immersed metal universal reduction screw tabs. Postoperative serum metal ion levels were elevated compared to baseline preoperative levels. In general, metal ion levels were considerably higher in the intraoperative fluid samples compared to those observed in the serum levels. CONCLUSION Our findings of contextually high metal ion concentrations in intraoperative and early postoperative samples provide further empirical support of a 'putting-in' phenomenon of metal ion release following instrumented spinal fusion. This challenges existing beliefs that metal ion release occurs during an intermediate 'wearing-in' phase. We recommend thorough irrigation of the operative site prior to wound closure to dilute and remove intraoperative metal ion debris. Possibilities of filtering trace metal ions from cell saver content may be considered.
Collapse
|
45
|
Liu B, Zhang X, Xiao GY, Lu YP. Phosphate chemical conversion coatings on metallic substrates for biomedical application: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 47:97-104. [DOI: 10.1016/j.msec.2014.11.038] [Citation(s) in RCA: 85] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2014] [Revised: 10/09/2014] [Accepted: 11/10/2014] [Indexed: 01/09/2023]
|
46
|
Kim SC, Lee HJ, Son SG, Seok HK, Lee KS, Shin SY, Lee JC. Aluminum-free low-modulus Ti-C composites that exhibit reduced image artifacts during MRI. Acta Biomater 2015; 12:322-331. [PMID: 25449916 DOI: 10.1016/j.actbio.2014.10.016] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2014] [Revised: 08/27/2014] [Accepted: 10/15/2014] [Indexed: 11/16/2022]
Abstract
Feasibility studies were performed to determine the suitability of a novel synthesis technique for fabricating multifunctional composite materials for orthopedic implants. By blending paramagnetic Ti powder with diamagnetic graphite and consolidating the resulting mixtures, Ti-C composites that cannot be feasibly obtained via conventional alloying techniques or ingot metallurgy were synthesized. The synthesized composite material exhibited extremely low magnetic susceptibility (χ=67.6×10(-6)), and, as a result, exhibited fewer artifacts during magnetic resonance imaging. The strength of the composite material (σ=770MPa) was such that it could support external loads to which the human body is subjected, but its Young's modulus was low (E=81.9 GPa) such that it could mitigate the stress-shielding effect. The material was also free from toxic elements such as Al and V and, thus, can be considered less harmful.
Collapse
Affiliation(s)
- Sung-Chul Kim
- Department of Materials Science and Engineering, Korea University, Seoul 136-713, Republic of Korea
| | - Hong-Jun Lee
- Department of Materials Science and Engineering, Korea University, Seoul 136-713, Republic of Korea
| | - Seong-Guk Son
- Department of Materials Science and Engineering, Korea University, Seoul 136-713, Republic of Korea
| | - Hyun-Kwang Seok
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology, Seoul 136-791, Republic of Korea
| | - Kang-Sik Lee
- Department of Orthopedic Surgery, ASAN Medical Center, Seoul 138-736, Republic of Korea
| | - Seung-Young Shin
- Eco-materials & Processing Department, Korea Institute of Industrial Technology, Incheon 406-840, Republic of Korea
| | - Jae-Chul Lee
- Department of Materials Science and Engineering, Korea University, Seoul 136-713, Republic of Korea.
| |
Collapse
|
47
|
|
48
|
Abstract
BACKGROUND Metal ion release is common following total hip arthroplasty, yet postoperative levels have not been defined for most stems currently used in clinical practice. AIM To assess metal ion release in the serum of patients with well functioning unilateral Exeter V40 primary total hip arthroplasties one year after surgery. METHODS Whole blood chromium and serum cobalt levels were measured in 20 patients following primary total hip arthroplasty with the Exeter V40 stem and a variety of acetabular components one year after surgery. RESULTS Whole blood chromium levels were within the normal range (10-100 nmol/L), with a single mild elevation of serum cobalt (normal <20 nmol/L). CONCLUSIONS In well functioning primary unilateral total hip arthroplasty using the Exeter V40 stem with a variety of acetabular components one year post surgery, whole blood chromium levels are normal and serum cobalt elevations are rare and mild.
Collapse
|
49
|
Walschot LHB, Aquarius R, Verdonschot N, Buma P, Schreurs BW. Porous titanium particles for acetabular reconstruction in total hip replacement show extensive bony armoring after 15 weeks. A loaded in vivo study in 10 goats. Acta Orthop 2014; 85:600-8. [PMID: 25238431 PMCID: PMC4259031 DOI: 10.3109/17453674.2014.960660] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE The bone impaction grafting technique restores bone defects in total hip replacement. Porous titanium particles (TiPs) are deformable, like bone particles, and offer better primary stability. We addressed the following questions in this animal study: are impacted TiPs osteoconductive under loaded conditions; do released micro-particles accelerate wear; and are systemic titanium blood levels elevated after implantation of TiPs? ANIMALS AND METHODS An AAOS type-III defect was created in the right acetabulum of 10 goats weighing 63 (SD 6) kg, and reconstructed with calcium phosphate-coated TiPs and a cemented polyethylene cup. A stem with a cobalt chrome head was cemented in the femur. The goats were killed after 15 weeks. Blood samples were taken pre- and postoperatively. RESULTS The TiP-graft layer measured 5.6 (SD 0.8) mm with a mean bone ingrowth distance of 2.8 (SD 0.8) mm. Cement penetrated 0.9 (0.3-1.9) mm into the TiPs. 1 reconstruction showed minimal cement penetration (0.3 mm) and failed at the cement-TiP interface. There were no signs of accelerated wear, metallic particle debris, or osteolysis. Median systemic titanium concentrations increased on a log-linear scale from 0.5 (0.3-1.1) parts per billion (ppb) to 0.9 (0.5-2.8) ppb (p=0.01). INTERPRETATION Adequate cement pressurization is advocated for impaction grafting with TiPs. After implantation, calcium phosphate-coated TiPs were osteoconductive under loaded conditions and caused an increase in systemic titanium concentrations. However, absolute levels remained low. There were no signs of accelerated wear. A clinical pilot study should be performed to prove that application in humans is safe in the long term.
Collapse
Affiliation(s)
| | - René Aquarius
- Department of Orthopaedics, Orthopaedic Research Laboratory, Radboud University Medical Centre, Nijmegen
| | - Nico Verdonschot
- Department of Orthopaedics, Orthopaedic Research Laboratory, Radboud University Medical Centre, Nijmegen,Laboratory of Biomechanical Engineering, University of Twente, Enschede, the Netherlands
| | - Pieter Buma
- Department of Orthopaedics, Orthopaedic Research Laboratory, Radboud University Medical Centre, Nijmegen
| | - B Willem Schreurs
- Department of Orthopaedics, Radboud University Medical Centre, Nijmegen
| |
Collapse
|
50
|
Ozkanli S, Soylemez MS, Sahin A, Senol S, Bilsel K, Ceylan HH. Unusual implant-related soft tissue reaction presenting as a swollen leg: a case report. J Med Case Rep 2014; 8:187. [PMID: 24927814 PMCID: PMC4082173 DOI: 10.1186/1752-1947-8-187] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2014] [Accepted: 03/31/2014] [Indexed: 11/11/2022] Open
Abstract
INTRODUCTION There are several causes of peri-implant edema, pain, and swelling around implants after orthopedic fixation device application for fracture repair. The most common and well-known reason is infection, however, granulomas associated with foreign body reactions are rarely seen. In this report we present a case of a granulomatous reaction mimicking a hydatid cyst and sarcoma. We emphasize the importance of differential diagnosis in triggering appropriate management of the patient. Our case was unusual; to the best of our knowledge no similar clinical or pathological findings have been reported in current literature. CASE PRESENTATION A 56-year-old Turkish man who had been treated for a right femoral fracture via a plate fixation 10 years prior underwent an operation to treat pain and swelling around the plate. A hydatid cyst-like mass was observed during surgery, but subsequent examination revealed that no hydatid cyst was present; both malignancy and infection were also absent. CONCLUSIONS Although infection is generally the first possibility that should be considered in a patient complaining of pain and swelling in the vicinity of an implant, malignancies, hydatid cysts, and (finally) foreign body reactions should also be kept in mind as differential diagnoses. A soft-tissue reaction around a previously implanted plate should be managed carefully. Pre-operative radiological assessment, and biopsy to allow pathological and microbiological examination, should be considered in all suspected cases.
Collapse
Affiliation(s)
- Seyma Ozkanli
- Department of Pathology, Göztepe Training and Research Hospital, Fahrettin Kerim Gökay Street, 2346 Istanbul, Turkey
| | - Mehmet Salih Soylemez
- Department of Orthopedics and Traumatology, Göztepe Training and Research Hospital, Fahrettin Kerim Gökay Street, 2346 Istanbul, Turkey
- Göztepe E.A.H. floor 3. Orthopaedics ward, Fahrettin Kerim Gökay Street, 2346 Kadıköy/Istanbul, Turkey
| | - Adem Sahin
- Department of Orthopedics and Traumatology, Göztepe Training and Research Hospital, Fahrettin Kerim Gökay Street, 2346 Istanbul, Turkey
| | - Serkan Senol
- Department of Pathology, Göztepe Training and Research Hospital, Fahrettin Kerim Gökay Street, 2346 Istanbul, Turkey
| | - Kerem Bilsel
- Department of Orthopedics and Traumatology, School of Medicine, Bezmialem Vakıf University, Vatan Street, 34080 Istanbul, Turkey
| | - Hasan Hüseyin Ceylan
- Department of Orthopedics and Traumatology, School of Medicine, Bezmialem Vakıf University, Vatan Street, 34080 Istanbul, Turkey
| |
Collapse
|