Mirzajani H, Abbasiasl T, Mirlou F, Istif E, Bathaei MJ, Dağ Ç, Deyneli O, Yazıcı D, Beker L. An ultra-compact and wireless tag for battery-free sweat glucose monitoring. Biosens Bioelectron 2022; 213:114450. [PMID: 35688025 DOI: 10.1016/j.bios.2022.114450] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 05/29/2022] [Accepted: 05/31/2022] [Indexed: 11/02/2022]
Abstract
Glucose monitoring before, during, and after exercise is essential for people with diabetes as exercise increases the risk of activity-induced hyper- and hypo-glycemic events. The situation is even more challenging for athletes with diabetes as they have impaired metabolic control compared to sedentary individuals. In this regard, a compact and noninvasive wearable glucose monitoring device that can be easily worn is critical to enabling glucose monitoring. This report presents an ultra-compact glucose tag with a footprint and weight of 1.2 cm2 and 0.13 g, respectively, for sweat analysis. The device comprises a near field communication (NFC) chip, antenna, electrochemical sensor, and microfluidic channels implemented in different material layers. The device has a flexible and conformal structure and can be easily attached to different body parts. The battery-less operation of the device was enabled by NFC-based wireless power transmission and the compact antenna. Femtosecond laser ablation was employed to fabricate a highly compact and flexible NFC antenna. The proposed device demonstrated excellent operating characteristics with a limit of detection (LOD), limit of quantification (LOQ), and sensitivity of 24 μM, 74 μM, and 1.27 μA cm-2 mM-1, respectively. The response of the proposed sensor in sweat glucose detection and quantification was validated by nuclear magnetic resonance spectroscopy (NMR). Also, the device's capability in attachment to the body, sweat collection, and glucose measurement was demonstrated through in vitro and in vivo experiments, and satisfactory results were obtained.
Collapse
Affiliation(s)
- Hadi Mirzajani
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey
| | - Taher Abbasiasl
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey
| | - Fariborz Mirlou
- Department of Biomedical Sciences and Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey
| | - Emin Istif
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey
| | - Mohammad Javad Bathaei
- Department of Biomedical Sciences and Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey
| | - Çağdaş Dağ
- Department of Molecular Biology and Genetics, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey; Nanofabrication and Nanocharacterization Centre for Scientific and Technological Advanced Research, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey; Koç University İşBank Centre for Infectious Diseases, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey
| | - Oğuzhan Deyneli
- Division of Endocrinology, Department of Internal Medicine, School of Medicine, Koç University Hospital, Topkapı Caddesi, Zeytinburnu, Istanbul, Turkey
| | - Dilek Yazıcı
- Division of Endocrinology, Department of Internal Medicine, School of Medicine, Koç University Hospital, Topkapı Caddesi, Zeytinburnu, Istanbul, Turkey
| | - Levent Beker
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey; Koç University Research Center for Translational Research (KUTTAM), Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey.
| |
Collapse
|
52
|
Steijlen ASM, Jansen KMB, Bastemeijer J, French PJ, Bossche A. Low-Cost Wearable Fluidic Sweat Collection Patch for Continuous Analyte Monitoring and Offline Analysis. Anal Chem 2022; 94:6893-6901. [PMID: 35486709 PMCID: PMC9096792 DOI: 10.1021/acs.analchem.2c01052] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Sweat sensors allow for new unobtrusive ways to continuously monitor an athlete's performance and health status. Significant advances have been made in the optimization of sensitivity, selectivity, and durability of electrochemical sweat sensors. However, comparing the in situ performance of these sensors in detail remains challenging because standardized sweat measurement methods to validate sweat sensors in a physiological setting do not yet exist. Current collection methods, such as the absorbent patch technique, are prone to contamination and are labor-intensive, which limits the number of samples that can be collected over time for offline reference measurements. We present an easy-to-fabricate sweat collection system that allows for continuous electrochemical monitoring, as well as chronological sampling of sweat for offline analysis. The patch consists of an analysis chamber hosting a conductivity sensor and a sequence of 5 to 10 reservoirs that contain level indicators that monitor the filling speed. After testing the performance of the patch in the laboratory, elaborate physiological validation experiments (3 patch locations, 6 participants) were executed. The continuous sweat conductivity measurements were compared with laboratory [Na+] and [Cl-] measurements of the samples, and a strong linear relationship (R2 = 0.97) was found. Furthermore, sweat rate derived from ventilated capsule measurement at the three locations was compared with patch filling speed and continuous conductivity readings. As expected from the literature, sweat conductivity was linearly related to sweat rate as well. In short, a successfully validated sweat collection patch is presented that enables sensor developers to systematically validate novel sweat sensors in a physiological setting.
Collapse
Affiliation(s)
- Annemarijn S M Steijlen
- Faculty of Electrical Engineering, Mathematics & Computer Science, Delft University of Technology, Mekelweg 4, Delft 2628 CD, The Netherlands
| | - Kaspar M B Jansen
- Faculty of Industrial Design Engineering, Delft University of Technology, Landbergstraat 15, Delft 2628 CE, The Netherlands
| | - Jeroen Bastemeijer
- Faculty of Electrical Engineering, Mathematics & Computer Science, Delft University of Technology, Mekelweg 4, Delft 2628 CD, The Netherlands
| | - Paddy J French
- Faculty of Electrical Engineering, Mathematics & Computer Science, Delft University of Technology, Mekelweg 4, Delft 2628 CD, The Netherlands
| | - Andre Bossche
- Faculty of Electrical Engineering, Mathematics & Computer Science, Delft University of Technology, Mekelweg 4, Delft 2628 CD, The Netherlands
| |
Collapse
|
53
|
|
54
|
A touch-based multimodal and cryptographic bio-human-machine interface. Proc Natl Acad Sci U S A 2022; 119:e2201937119. [PMID: 35377784 PMCID: PMC9169842 DOI: 10.1073/pnas.2201937119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
The awareness of the individuals’ biological status is critical for creating interactive environments. Accordingly, we devised a multimodal cryptographic bio-human–machine interface (CB-HMI), which seamlessly translates touch-based entries into encrypted biochemical, biophysical, and biometric indices (i.e., circulating biomarkers levels, heart rate, oxygen saturation level, and fingerprint pattern). As its central component, the CB-HMI features thin hydrogel-coated chemical sensors and a signal interpretation framework to access/interpret biochemical indices, bypassing the challenge of circulating analyte accessibility and the confounding effect of pressing force variability. Upgrading the surrounding objects with CB-HMI, we demonstrated new interactive solutions for driving safety and medication use, where the integrated CB-HMI uniquely enabled one-touch bioauthentication (based on the user’s biological state/identity), prior to rendering the intended services. The awareness of individuals’ biological status is critical for creating interactive and adaptive environments that can actively assist the users to achieve optimal outcomes. Accordingly, specialized human–machine interfaces—equipped with bioperception and interpretation capabilities—are required. To this end, we devised a multimodal cryptographic bio-human–machine interface (CB-HMI), which seamlessly translates the user’s touch-based entries into encrypted biochemical, biophysical, and biometric indices. As its central component, the CB-HMI features thin hydrogel-coated chemical sensors and inference algorithms to noninvasively and inconspicuously acquire biochemical indices such as circulating molecules that partition onto the skin (here, ethanol and acetaminophen). Additionally, the CB-HMI hosts physical sensors and associated algorithms to simultaneously acquire the user’s heart rate, blood oxygen level, and fingerprint minutiae pattern. Supported by human subject studies, we demonstrated the CB-HMI’s capability in terms of acquiring physiologically relevant readouts of target bioindices, as well as user-identifying and biometrically encrypting/decrypting these indices in situ (leveraging the fingerprint feature). By upgrading the common surrounding objects with the CB-HMI, we created interactive solutions for driving safety and medication use. Specifically, we demonstrated a vehicle-activation system and a medication-dispensing system, where the integrated CB-HMI uniquely enabled user bioauthentication (on the basis of the user’s biological state and identity) prior to rendering the intended services. Harnessing the levels of bioperception achieved by the CB-HMI and other intelligent HMIs, we can equip our surroundings with a comprehensive and deep awareness of individuals’ psychophysiological state and needs.
Collapse
|
55
|
Jeerapan I, Moonla C, Thavarungkul P, Kanatharana P. Lab on a body for biomedical electrochemical sensing applications: The next generation of microfluidic devices. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 187:249-279. [PMID: 35094777 DOI: 10.1016/bs.pmbts.2021.07.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
This chapter highlights applications of microfluidic devices toward on-body biosensors. The emerging application of microfluidics to on-body bioanalysis is a new strategy to establish systems for the continuous, real-time, and on-site determination of informative markers present in biofluids, such as sweat, interstitial fluid, blood, saliva, and tear. Electrochemical sensors are attractive to integrate with such microfluidics due to the possibility to be miniaturized. Moreover, on-body microfluidics coupled with bioelectronics enable smart integration with modern information and communication technology. This chapter discusses requirements and several challenges when developing on-body microfluidics such as difficulties in manipulating small sample volumes while maintaining mechanical flexibility, power-consumption efficiency, and simplicity of total automated systems. We describe key components, e.g., microchannels, microvalves, and electrochemical detectors, used in microfluidics. We also introduce representatives of advanced lab-on-a-body microfluidics combined with electrochemical sensors for biomedical applications. The chapter ends with a discussion of the potential trends of research in this field and opportunities. On-body microfluidics as modern total analysis devices will continue to bring several fascinating opportunities to the field of biomedical and translational research applications.
Collapse
Affiliation(s)
- Itthipon Jeerapan
- Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, Thailand.
| | - Chochanon Moonla
- School of Chemistry, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima, Thailand
| | - Panote Thavarungkul
- Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| | - Proespichaya Kanatharana
- Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, Thailand; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| |
Collapse
|
56
|
Kukkar D, Zhang D, Jeon B, Kim KH. Recent advances in wearable biosensors for non-invasive monitoring of specific metabolites and electrolytes associated with chronic kidney disease: Performance evaluation and future challenges. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116570] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
57
|
Wu H, Chen J, Yang Y, Yu W, Chen Y, Lin P, Liang K. Smartphone-coupled three-layered paper-based microfluidic chips demonstrating stereoscopic capillary-driven fluid transport towards colorimetric detection of pesticides. Anal Bioanal Chem 2022; 414:1759-1772. [DOI: 10.1007/s00216-021-03839-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 12/02/2021] [Accepted: 12/07/2021] [Indexed: 11/01/2022]
|
58
|
Dervisevic M, Alba M, Esser L, Tabassum N, Prieto-Simon B, Voelcker NH. Silicon Micropillar Array-Based Wearable Sweat Glucose Sensor. ACS APPLIED MATERIALS & INTERFACES 2022; 14:2401-2410. [PMID: 34968024 DOI: 10.1021/acsami.1c22383] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Wearable technologies have great potential in health monitoring and disease diagnostics. As a consequence, interest in the study of wearable sensors has dramatically increased over recent years. Successful translation of this technology from research prototypes to commercial products requires addressing some of the major challenges faced by wearable sensors such as loss of, and damage in, the biological recognition layer of the skin-interfaced sensors. In this work, we propose a solution to this challenge by integrating micropillar array (MPA) surfaces as part of the sensing layer with the aim to protect and prevent the loss of the enzyme layer from mechanical stress while the sensor is worn. The proposed wearable sensing patch is composed of reference, counter, and working electrodes, all made of MPAs and is designed for measuring glucose in sweat. MPA sensing patch has a wide linear range of 50 μM to 1.4 mM, a sensitivity of 4.7 ± 0.8 μA mM-1, and a limit of detection of 26 ± 5 μM. The glucose sensing patch was tested using human sweat where glucose-level changes were successfully measured before and after meal consumption. The developed patch provides an alternative solution to the problem of the damage to the sensor microenvironment upon wear. But in addition, it also offers a user-friendly, cost-effective, and reliable sweat analysis platform with significant potential in health monitoring applications.
Collapse
Affiliation(s)
- Muamer Dervisevic
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia
| | - Maria Alba
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia
- Commonwealth Scientific and Industrial Research Organization (CSIRO), Clayton, Victoria 3168, Australia
| | - Lars Esser
- Commonwealth Scientific and Industrial Research Organization (CSIRO), Clayton, Victoria 3168, Australia
| | - Nazia Tabassum
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia
| | - Beatriz Prieto-Simon
- Department of Electronic Engineering, Universitat Rovira i Virgili, Tarragona 43007, Spain
| | - Nicolas H Voelcker
- Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia
- Commonwealth Scientific and Industrial Research Organization (CSIRO), Clayton, Victoria 3168, Australia
- Melbourne Centre for Nanofabrication, Victorian Node of the Australian National Fabrication Facility, Clayton, Victoria 3168, Australia
- Materials Science and Engineering, Monash University, Clayton, Victoria 3168, Australia
| |
Collapse
|
59
|
Wang B, Zhao C, Wang Z, Yang KA, Cheng X, Liu W, Yu W, Lin S, Zhao Y, Cheung KM, Lin H, Hojaiji H, Weiss PS, Stojanović MN, Tomiyama AJ, Andrews AM, Emaminejad S. Wearable aptamer-field-effect transistor sensing system for noninvasive cortisol monitoring. SCIENCE ADVANCES 2022; 8:eabk0967. [PMID: 34985954 PMCID: PMC8730602 DOI: 10.1126/sciadv.abk0967] [Citation(s) in RCA: 139] [Impact Index Per Article: 46.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Wearable technologies for personalized monitoring require sensors that track biomarkers often present at low levels. Cortisol—a key stress biomarker—is present in sweat at low nanomolar concentrations. Previous wearable sensing systems are limited to analytes in the micromolar-millimolar ranges. To overcome this and other limitations, we developed a flexible field-effect transistor (FET) biosensor array that exploits a previously unreported cortisol aptamer coupled to nanometer-thin-film In2O3 FETs. Cortisol levels were determined via molecular recognition by aptamers where binding was transduced to electrical signals on FETs. The physiological relevance of cortisol as a stress biomarker was demonstrated by tracking salivary cortisol levels in participants in a Trier Social Stress Test and establishing correlations between cortisol in diurnal saliva and sweat samples. These correlations motivated the development and on-body validation of an aptamer-FET array–based smartwatch equipped with a custom, multichannel, self-referencing, and autonomous source measurement unit enabling seamless, real-time cortisol sweat sensing.
Collapse
Affiliation(s)
- Bo Wang
- Interconnected and Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Chuanzhen Zhao
- Department of Chemistry and Biochemistry, University of California, Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Zhaoqing Wang
- Interconnected and Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Kyung-Ae Yang
- Division of Experimental Therapeutics, Department of Medicine, Columbia University, New York, NY 10032, USA
| | - Xuanbing Cheng
- Interconnected and Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Department of Materials Science and Engineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Wenfei Liu
- Department of Chemistry and Biochemistry, University of California, Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Wenzhuo Yu
- Interconnected and Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Shuyu Lin
- Interconnected and Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Yichao Zhao
- Interconnected and Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Department of Materials Science and Engineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Kevin M. Cheung
- Department of Chemistry and Biochemistry, University of California, Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Haisong Lin
- Interconnected and Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Hannaneh Hojaiji
- Interconnected and Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Paul S. Weiss
- Department of Chemistry and Biochemistry, University of California, Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Department of Materials Science and Engineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Milan N. Stojanović
- Division of Experimental Therapeutics, Department of Medicine, Columbia University, New York, NY 10032, USA
- Department of Biomedical Engineering, Columbia University, New York, NY 10032, USA
| | - A. Janet Tomiyama
- Department of Psychology, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Anne M. Andrews
- Department of Chemistry and Biochemistry, University of California, Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Department of Psychiatry and Biobehavioral Sciences, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Semel Institute for Neuroscience and Human Behavior, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Hatos Center for Neuropharmacology, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Corresponding author. (A.M.A.); (S.E.)
| | - Sam Emaminejad
- Interconnected and Integrated Bioelectronics Lab (IBL), Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Corresponding author. (A.M.A.); (S.E.)
| |
Collapse
|
60
|
Wearable tesla valve-based sweat collection device for sweat colorimetric analysis. Talanta 2022; 240:123208. [PMID: 34998143 DOI: 10.1016/j.talanta.2022.123208] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/29/2021] [Accepted: 01/03/2022] [Indexed: 01/05/2023]
Abstract
Sweat sensor has become one of the most important developing directions of in vitro wearable diagnostic device in recent years. Stable sweat collecting device is the key to realize sweat component analysis. In order to ensure that the collected sweat is not subject to component analysis errors caused by evaporation or environmental pollution, mechanical micro-valves were adopted for microfluidic sweat collection devices to realize sealed storage of sweat. However, this poses a challenge to the stability of machining and reusability of the acquisition device. In this work, the Tesla valve without any mechanical structure were introduced into the design of sweat collection chip. And made full use of its diodicity to improve the collection to a certain extent, prevent backflow at the entrance, and restrain the flow at the exit to contact with the outside world. In addition, through optimizing the shunt angle, branch channel parameters of Tesla valve, boosted its diodicity under low flow rate. Furthermore, a sweat storage chamber with baffle structure that can achieve maximum static storage area was adopted to form a whole sweat collection chip. The design was verified through the flow experiment of methylene blue and methyl red indicators on the chip. Through modification of the filter paper fixed in the collection chamber, the colorimetric analysis of glucose and pH was realized. This device may provide new inspirations for the development of wearable sweat sensor.
Collapse
|
61
|
Zhong B, Jiang K, Wang L, Shen G. Wearable Sweat Loss Measuring Devices: From the Role of Sweat Loss to Advanced Mechanisms and Designs. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2103257. [PMID: 34713981 PMCID: PMC8728835 DOI: 10.1002/advs.202103257] [Citation(s) in RCA: 57] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 09/15/2021] [Indexed: 05/22/2023]
Abstract
Wearable sweat sensors have received significant research interest and have become popular as sweat contains considerable health information about physiological and psychological states. However, measured biomarker concentrations vary with sweat rates, which has a significant effect on the accuracy and reliability of sweat biosensors. Wearable sweat loss measuring devices (SLMDs) have recently been proposed to overcome the limitations of biomarker tracking and reduce inter- and intraindividual variability. In addition, they offer substantial potential for monitoring human body homeostasis, because sweat loss plays an indispensable role in thermoregulation and skin hydration. Previous studies have not carried out a comprehensive and systematic review of the principles, importance, and development of wearable SLMDs. This paper reviews wearable SLMDs with a new health perspective from the role of sweat loss to advanced mechanisms and designs. Two types of sweat and their measurement significance for practical applications are highlighted. Then, a comprehensive review of advances in different wearable SLMDs based on hygrometers, absorbent materials, and microfluidics is presented by describing their respective device architectures, present situations, and future directions. Finally, concluding remarks on opportunities for future application fields and challenges for future sweat sensing are presented.
Collapse
Affiliation(s)
- Bowen Zhong
- State Key Laboratory for Superlattices and Microstructures, Institution of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100029, China
| | - Kai Jiang
- Faculty of Hepato-Pancreato-Biliary Surgery, Chinese PLA General Hospital, Institute of Hepatobiliary Surgery of Chinese PLA, Key Laboratory of Digital Hepatobiliary Surgery, Chinese PLA, Beijing, 100853, China
| | - Lili Wang
- State Key Laboratory for Superlattices and Microstructures, Institution of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100029, China
| | - Guozhen Shen
- State Key Laboratory for Superlattices and Microstructures, Institution of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100029, China
| |
Collapse
|
62
|
Hu X, Yang F, Zhao H, Guo M, Wang Y. Design and Evaluation of Three-Dimensional Zigzag Chaotic Micromixers for Biochemical Applications. Ind Eng Chem Res 2021. [DOI: 10.1021/acs.iecr.1c02435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Xingjian Hu
- State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
| | - Fan Yang
- State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
| | - Haiyan Zhao
- State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
| | - Mingzhao Guo
- State Key Laboratory of Chemical Engineering, Department of Chemical Engineering, Tsinghua University, Beijing 100084, China
| | - Yujun Wang
- State Key Laboratory of Chemical Engineering, Department of Chemical Engineering, Tsinghua University, Beijing 100084, China
| |
Collapse
|
63
|
Yang B, Jiang X, Fang X, Kong J. Wearable chem-biosensing devices: from basic research to commercial market. LAB ON A CHIP 2021; 21:4285-4310. [PMID: 34672310 DOI: 10.1039/d1lc00438g] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Wearable chem-biosensors have been garnering tremendous interest due to the significant potential in tailored healthcare diagnostics and therapeutics. With the development of the medical diagnostics revolution, wearable chem-biosensors as a rapidly emerging wave allow individuals to perform on-demand detection and obtain the required in-depth information. In contrast to commercial wearables, which tend to be miniaturized for measuring physical activities, the recent progressive wearable chem-biosensing device have mainly focused on non-invasive or minimally invasive monitoring biomarkers at the molecular level. Wearables is a multidisciplinary subject, and chem-biosensing is one of the most significant technologies. In this review, the currently basic academic research of wearable chem-biosensing devices and its commercial transformation were summarized and highlighted. Moreover, some representative wearable products on the market for individual health managements are presented. Strategies for the identification and sensing of biomarkers are discussed to further promote the development of wearable chem-biosensing devices. We also shared the limitations and breakthroughs of the next generation of chemo-biosensor wearables, from home use to clinical diagnosis.
Collapse
Affiliation(s)
- Bin Yang
- Department of Chemistry and Institutes of Biomedical Sciences, Fudan University, Shanghai, 200433, P. R. China.
| | - Xingyu Jiang
- Department of Biomedical Engineering, Shenzhen Bay Laboratory, Southern University of Science and Technology, Shenzhen, 518055, P. R. China.
| | - Xueen Fang
- Department of Chemistry and Institutes of Biomedical Sciences, Fudan University, Shanghai, 200433, P. R. China.
| | - Jilie Kong
- Department of Chemistry and Institutes of Biomedical Sciences, Fudan University, Shanghai, 200433, P. R. China.
| |
Collapse
|
64
|
Kim KK, Choi J, Ko SH. Energy Harvesting Untethered Soft Electronic Devices. Adv Healthc Mater 2021; 10:e2002286. [PMID: 33929767 DOI: 10.1002/adhm.202002286] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 04/11/2021] [Indexed: 12/24/2022]
Abstract
Advances in wearable and stretchable electronic technologies have yielded a wide range of electronic devices that can be conformably worn by, or implanted in humans to measure physiological signals. Moreover, various cutting-edge technologies for battery-free electronic devices have led to advances in healthcare devices that can continuously measure long-term biosignals for advanced human-machine interface and clinical diagnostics. This report presents the recent progress in battery-less, wearable devices using a wide range of energy harvesting sources, such as electromagnetic energy, mechanical energy, and biofuels. Additionally, this report also discusses the principles and working mechanisms of near/far-field communications, triboelectric, thermoelectric, and biofuel technologies.
Collapse
Affiliation(s)
- Kyun Kyu Kim
- Applied Nano and Thermal Science Lab Department of Mechanical Engineering Seoul National University 1 Gwanak‐ro, Gwanak‐gu Seoul 151‐742 Korea
| | - Joonhwa Choi
- Applied Nano and Thermal Science Lab Department of Mechanical Engineering Seoul National University 1 Gwanak‐ro, Gwanak‐gu Seoul 151‐742 Korea
| | - Seung Hwan Ko
- Applied Nano and Thermal Science Lab Department of Mechanical Engineering Seoul National University 1 Gwanak‐ro, Gwanak‐gu Seoul 151‐742 Korea
- Institute of Advanced Machines and Design Seoul National University Seoul 08826 Korea
- Institute of Engineering Research Seoul National University Seoul 08826 Korea
| |
Collapse
|
65
|
Ghaffari R, Yang DS, Kim J, Mansour A, Wright JA, Model JB, Wright DE, Rogers JA, Ray TR. State of Sweat: Emerging Wearable Systems for Real-Time, Noninvasive Sweat Sensing and Analytics. ACS Sens 2021; 6:2787-2801. [PMID: 34351759 DOI: 10.1021/acssensors.1c01133] [Citation(s) in RCA: 58] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Skin-interfaced wearable systems with integrated colorimetric assays, microfluidic channels, and electrochemical sensors offer powerful capabilities for noninvasive, real-time sweat analysis. This Perspective details recent progress in the development and translation of novel wearable sensors for personalized assessment of sweat dynamics and biomarkers, with precise sampling and real-time analysis. Sensor accuracy, system ruggedness, and large-scale deployment in remote environments represent key opportunity areas, enabling broad deployment in the context of field studies, clinical trials, and recent commercialization. On-body measurements in these contexts show good agreement compared to conventional laboratory-based sweat analysis approaches. These device demonstrations highlight the utility of biochemical sensing platforms for personalized assessment of performance, wellness, and health across a broad range of applications.
Collapse
Affiliation(s)
- Roozbeh Ghaffari
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Da Som Yang
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
| | - Joohee Kim
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
| | - Amer Mansour
- Division of Biological Sciences, The University of Chicago, Chicago, Illinois 60637, United States
| | - John A. Wright
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Jeffrey B. Model
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Donald E. Wright
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - John A. Rogers
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
- Departments of Materials Science and Engineering, Mechanical Engineering, Electrical and Computer Engineering, and Chemistry, Northwestern University, Evanston, Illinois 60202, United States
- Department of Neurological Surgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois 60611, United States
| | - Tyler R. Ray
- Department of Mechanical Engineering, University of Hawai’i at Ma̅noa, Honolulu, Hawaii 96822, United States
- Department of Cell and Molecular Biology, John A. Burns School of Medicine, University of Hawai’i at Ma̅noa, Honolulu, Hawaii 96813, United States
| |
Collapse
|
66
|
Chi H, Xu Z, Zhang T, Li X, Wu Z, Zhao Y. Randomly heterogeneous oleophobic/pH-responsive polymer coatings with reversible wettability transition for multifunctional fabrics and controllable oil-water separation. J Colloid Interface Sci 2021; 594:122-130. [PMID: 33756360 DOI: 10.1016/j.jcis.2021.02.097] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2020] [Revised: 02/21/2021] [Accepted: 02/23/2021] [Indexed: 11/16/2022]
Abstract
Stimuli-responsive surfaces with wettability change between superhydrophilic and superhydrophobic are susceptible to oil contamination which often ruins the surface. Herein, a coating with pH-switchable wettability transition between superamphiphobic and superhydrophilic-superoleophobic is achieved by rationally designing oleophobic/pH-responsive polymer heterogeneous chemistry. Fabrics modified with this coating show repellency to both water and oils, while upon exposure to acidic water (pH = 1) the fabrics change to be superhydrophilic-superoleophobic within a short response time of <5 s. More importantly, the superamphiphobicity of the fabric can be restored under mild alkaline condition (pH = 10), and the transition is reversible for many cycles. The effective in situ or ex situ wettability change under acidic/alkaline water treatment makes the coated fabric capable of separating oil-water mixture or even some mixtures of immiscible organic solvents. In addition, the coated fabric is also demonstrated to be promising as a new class of functional fabrics that provide protection against water and many oils in one condition, and can change to be hygroscopic, anti-static, oil-repellent and anti-oil-fouling in the other condition for improved wear comfort and self-cleaning.
Collapse
Affiliation(s)
- Huanjie Chi
- College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China
| | - Zhiguang Xu
- China-Australia Institute for Advanced Materials and Manufacturing, Jiaxing University, Jiaxing 314001, China.
| | - Tao Zhang
- College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China
| | - Xiaomin Li
- College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China
| | - Zhu Wu
- College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China
| | - Yan Zhao
- College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China.
| |
Collapse
|
67
|
Jo S, Sung D, Kim S, Koo J. A review of wearable biosensors for sweat analysis. Biomed Eng Lett 2021; 11:117-129. [PMID: 34150348 DOI: 10.1007/s13534-021-00191-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 04/26/2021] [Accepted: 04/30/2021] [Indexed: 11/26/2022] Open
Abstract
Recent advances in the skin-interfaced wearable sweat sensors allow a personalized daily diagnosis and prognosis of the diseases in a form of a non-invasive, portable, and continuous monitoring system. Especially, the soft microfluidic system provides robust quantitative analysis platforms that integrate sweat sampling, storing, and various sensing capabilities. This review systematically introduces the sweat collecting mechanism using soft microfluidic valves, including calculation of sweat storage and loss. In terms of sweat analysis, colorimetric (e.g. enzymatic, chemical, or their mixed reactions), electrochemical (e.g. voltammetric, potentiometric, amperometric, or conductometric), and multiplex measurements of sweat contents facilitate diagnosis of diseases via analysis of combined multiple data, such as vital signals (e.g. ECG, EMG, EEG, etc.) and information from the skin (e.g. temperature, GSR, etc.). The integration of wireless communication with the microfluidic systems enables point-of-care health monitoring for disease and specific physiological status.
Collapse
Affiliation(s)
- Seongbin Jo
- School of Biomedical Engineering, Korea University, Seoul, 02841 Republic of Korea
| | - Daeun Sung
- School of Biomedical Engineering, Korea University, Seoul, 02841 Republic of Korea
| | - Sungbong Kim
- Department of Materials Science and Engineering and Materials Research Laboratory, University of Illinois At Urbana-Champaign, Urbana, IL 61801 USA
| | - Jahyun Koo
- School of Biomedical Engineering, Korea University, Seoul, 02841 Republic of Korea
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul, 02841 Republic of Korea
| |
Collapse
|
68
|
Xu K, Fujita Y, Lu Y, Honda S, Shiomi M, Arie T, Akita S, Takei K. A Wearable Body Condition Sensor System with Wireless Feedback Alarm Functions. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2008701. [PMID: 33772894 DOI: 10.1002/adma.202008701] [Citation(s) in RCA: 66] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/24/2020] [Revised: 01/30/2021] [Indexed: 05/21/2023]
Abstract
Emerging feedback systems based on tracking body conditions can save human lives. In particular, vulnerable populations such as disabled people, elderly, and infants often require special care. For example, the high global mortality of infants primarily owing to sudden infant death syndrome while sleeping makes request for extraordinary attentions in neonatal intensive care units or daily lives. Here, a versatile laser-induced graphene (LIG)-based integrated flexible sensor system, which can wirelessly monitor the sleeping postures, respiration rate, and diaper moisture with feedback alarm notifications, is reported. A tilt sensor based on confining a liquid metal droplet inside a cavity can track at least 18 slanting orientations. A rapid and scalable laser direct writing method realizes LIG patterning in both the in-plane and out-of-plane configurations as well as the formation of nonstick conductive structures to the liquid metal. By rationally merging the LIG-based tilt, strain, and humidity sensors on a thin flexible film, the multimodal sensor device is applied to a diaper as a real-time feedback tracking system of the sleeping posture, respiration, and wetness toward secure and comfortable lives. User-friendly interfaces, which incorporate alarming functions, provide timely feedback for caregivers tending to vulnerable populations with limited self-care capabilities.
Collapse
Affiliation(s)
- Kaichen Xu
- Department of Physics and Electronics, Osaka Prefecture University, Sakai, Osaka, 599-8531, Japan
| | - Yusuke Fujita
- Department of Physics and Electronics, Osaka Prefecture University, Sakai, Osaka, 599-8531, Japan
| | - Yuyao Lu
- Department of Physics and Electronics, Osaka Prefecture University, Sakai, Osaka, 599-8531, Japan
| | - Satoko Honda
- Department of Physics and Electronics, Osaka Prefecture University, Sakai, Osaka, 599-8531, Japan
| | - Mao Shiomi
- Department of Physics and Electronics, Osaka Prefecture University, Sakai, Osaka, 599-8531, Japan
| | - Takayuki Arie
- Department of Physics and Electronics, Osaka Prefecture University, Sakai, Osaka, 599-8531, Japan
| | - Seiji Akita
- Department of Physics and Electronics, Osaka Prefecture University, Sakai, Osaka, 599-8531, Japan
| | - Kuniharu Takei
- Department of Physics and Electronics, Osaka Prefecture University, Sakai, Osaka, 599-8531, Japan
- JST PRESTO, Kawaguchi, Saitama, 332-0012, Japan
| |
Collapse
|
69
|
Ghaffari R, Rogers JA, Ray TR. Recent progress, challenges, and opportunities for wearable biochemical sensors for sweat analysis. SENSORS AND ACTUATORS. B, CHEMICAL 2021; 332:129447. [PMID: 33542590 PMCID: PMC7853653 DOI: 10.1016/j.snb.2021.129447] [Citation(s) in RCA: 87] [Impact Index Per Article: 21.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Sweat is a promising, yet relatively unexplored biofluid containing biochemical information that offers broad insights into the underlying dynamic metabolic activity of the human body. The rich composition of electrolytes, metabolites, hormones, proteins, nucleic acids, micronutrients, and exogenous agents found in sweat dynamically vary in response to the state of health, stress, and diet. Emerging classes of skin-interfaced wearable sensors offer powerful capabilities for the real-time, continuous analysis of sweat produced by the eccrine glands in a manner suitable for use in athletics, consumer wellness, military, and healthcare industries. This perspective examines the rapid and continuous progress of wearable sweat sensors through the most advanced embodiments that address the fundamental challenges currently restricting widespread deployment. It concludes with a discussion of efforts to expand the overall utility of wearable sweat sensors and opportunities for commercialization, in which advances in biochemical sensor technologies will be critically important.
Collapse
Affiliation(s)
- Roozbeh Ghaffari
- -Querrey Simpson Institute for Bioelectronics and Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
- -Epicore Biosystems, Inc., Cambridge, MA, USA
| | - John A. Rogers
- -Querrey Simpson Institute for Bioelectronics and Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
- -Epicore Biosystems, Inc., Cambridge, MA, USA
- -Departments of Materials Science and Engineering, Mechanical Engineering, Electrical and Computer Engineering, Chemistry, Northwestern University, Evanston, IL, USA
- -Department of Neurological Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Tyler R. Ray
- -Department of Mechanical Engineering, University of Hawai‘i at Mānoa, Honolulu, HI
| |
Collapse
|
70
|
Vaquer A, Barón E, de la Rica R. Wearable Analytical Platform with Enzyme-Modulated Dynamic Range for the Simultaneous Colorimetric Detection of Sweat Volume and Sweat Biomarkers. ACS Sens 2021; 6:130-136. [PMID: 33371672 DOI: 10.1021/acssensors.0c01980] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
In this manuscript, we introduce a wearable analytical platform that simultaneously measures the concentration of sweat lactate and sample volume. It contains two sensors entirely made of filter paper that can be easily affixed on the skin with medical-grade tape. The lactate biosensor features a unique signal modulation mechanism that enables fine-tuning the dynamic range. It consists of adding a competitive enzyme inhibitor in different reservoirs. Thanks to this, it is possible to choose between a very low limit of detection (0.06 mM) and a linear response in the physiological concentration range (10-30 mM). The sweat volume sensor was obtained by adding a reservoir containing gold nanoparticles. As the wearer sweats, the nanoparticles are carried through a paper channel. This is used to gauge the volume of sample by measuring the distance traveled by the nanoprobes. Using fine-tuned lactate biosensors and combining them with the volume sensors allowed us to quantify variations in the levels of sweat lactate independently of the wearer's sweat rate during an exercise routine. The platform design can be customized to meet the end user's needs, which makes it ideal for developing a wide array of disposable wearable biosensors.
Collapse
Affiliation(s)
- Andreu Vaquer
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120 Palma de Mallorca, Spain
| | - Enrique Barón
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120 Palma de Mallorca, Spain
| | - Roberto de la Rica
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120 Palma de Mallorca, Spain
| |
Collapse
|
71
|
Abstract
Wearable electronics have been receiving increasing attention for the past few decades. Particularly, fiber-based electronics are considered to be ideal for many applications for their flexibility, lightweight, breathability, and comfortability. Furthermore, fibers and fiber-based textiles can be 3D-molded with ease and potentially integrated with everyday clothes or accessories. These properties are especially desired in the fields of bio-related sensors and energy-storage systems. Wearable sensors utilize a tight interface with human skin and clothes for continuous environmental scanning and non-invasive health monitoring. At the same time, their flexible and lightweight properties allow more convenient and user-friendly experiences to the wearers. Similarly, for the wearable devices to be more accessible, it is crucial to incorporate energy harvesting and storage systems into the device themselves, removing the need to attach an external power source. This review summarizes the recent applications of fibers and fiber-based textiles in mechanical, photonic, and biomedical sensors. Pressure and strain sensors and their implementation as electronic skins will be explored, along with other various fiber sensors capable of imaging objects or monitoring safety and health markers. In addition, we attempt to elucidate recent studies in energy-storing fibers and their implication in self-powered and fully wireless wearable devices.
Collapse
|
72
|
Hojaiji H, Zhao Y, Gong MC, Mallajosyula M, Tan J, Lin H, Hojaiji AM, Lin S, Milla C, Madni AM, Emaminejad S. An autonomous wearable system for diurnal sweat biomarker data acquisition. LAB ON A CHIP 2020; 20:4582-4591. [PMID: 33052990 DOI: 10.1039/d0lc00820f] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
To track dynamically varying and physiologically relevant biomarker profiles in sweat, autonomous wearable platforms are required to periodically sample and analyze sweat with minimal or no user intervention. Previously reported sweat sensors are functionally limited to capturing biomarker information at one time-point/period, thereby necessitating repeated user intervention to increase the temporal granularity of biomarker data. Accordingly, we present a compact multi-compartment wearable system, where each compartment can be activated to autonomously induce/modulate sweat secretion (via iontophoretic actuation) and analyze sweat at set time points. This system was developed following a hybrid-flex design and a vertical integration scheme-integrating the required functional modules: miniaturized iontophoresis interfaces, adhesive thin film microfluidic-sensing module, and control/readout electronics. The system was deployed in a human subject study to track the diurnal variation of sweat glucose levels in relation to the daily food intake. The demonstrated autonomous operation for diurnal sweat biomarker data acquisition illustrates the system's suitability for large-scale and longitudinal personal health monitoring applications.
Collapse
Affiliation(s)
- Hannaneh Hojaiji
- Interconnected and Integrated Bioelectronics Lab (I2BL), Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles, CA, USA. and Department of Electrical and Computer Engineering, University of California, Los Angeles, CA, USA
| | - Yichao Zhao
- Interconnected and Integrated Bioelectronics Lab (I2BL), Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles, CA, USA. and Department of Materials Science and Engineering, University of California, Los Angeles, CA, USA
| | - Max C Gong
- Interconnected and Integrated Bioelectronics Lab (I2BL), Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles, CA, USA. and Department of Electrical and Computer Engineering, University of California, Los Angeles, CA, USA
| | - Mudith Mallajosyula
- Interconnected and Integrated Bioelectronics Lab (I2BL), Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles, CA, USA. and Department of Computer Science and Engineering, University of California, Los Angeles, CA, USA
| | - Jiawei Tan
- Interconnected and Integrated Bioelectronics Lab (I2BL), Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles, CA, USA. and Department of Materials Science and Engineering, University of California, Los Angeles, CA, USA
| | - Haisong Lin
- Interconnected and Integrated Bioelectronics Lab (I2BL), Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles, CA, USA. and Department of Electrical and Computer Engineering, University of California, Los Angeles, CA, USA
| | - Amir M Hojaiji
- Interconnected and Integrated Bioelectronics Lab (I2BL), Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles, CA, USA.
| | - Shuyu Lin
- Interconnected and Integrated Bioelectronics Lab (I2BL), Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles, CA, USA. and Department of Electrical and Computer Engineering, University of California, Los Angeles, CA, USA
| | - Carlos Milla
- The Stanford Cystic Fibrosis Center, Center for Excellence in Pulmonary Biology, Stanford School of Medicine, Stanford, CA, USA
| | - Asad M Madni
- Department of Electrical and Computer Engineering, University of California, Los Angeles, CA, USA
| | - Sam Emaminejad
- Interconnected and Integrated Bioelectronics Lab (I2BL), Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles, CA, USA. and Department of Electrical and Computer Engineering, University of California, Los Angeles, CA, USA and Department of Bioengineering, University of California, Los Angeles, CA, USA
| |
Collapse
|
73
|
Ohashi T, Gerrett N, Shinkawa S, Sato T, Miyake R, Kondo N, Mitsuzawa S. Fluidic Patch Device to Sample Sweat for Accurate Measurement of Sweat Rate and Chemical Composition: A Proof-of-Concept Study. Anal Chem 2020; 92:15534-15541. [PMID: 33169984 DOI: 10.1021/acs.analchem.0c03466] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Sweat sensors that can continuously sample sweat are critical for determining the time-dependent physiological responses occurring in normal daily life. Here, a new device, termed fluidic patch, for collecting human sweat samples at defined time intervals is developed, and the proof-of-concept is demonstrated. The device comprises micropumps and a disposable microfluidic patch attached to the human skin. The fluidic patch continuously collects aliquots of freshly secreted sweat accumulated in the fluidic pathway at accurately defined time windows (typically 5 min). By measuring the weight of the collected samples, the local sweat rate is calculated. The sweat sample collected can be directly subjected to a wide range of chemical analyses. For the proof-of-concept, we compared the sweat rates during passive heating in human trials using the fluidic patch and the conventional ventilated sweat capsule system. Although the sweat rate obtained using the fluidic patch highly correlated with that of the ventilated sweat capsule (R2 = 0.96, y = 1.4x - 0.05), the fluidic patch overestimated the sweat rate compared with the ventilated capsule system when the sweat rate exceeded 0.5 mg/(cm2·min). The sampled sweat was analyzed for sodium, potassium, chloride, lactate, pyruvate, and cortisol. The device could obtain the time courses of the concentrations of the abovementioned three ions; the concentrations of sodium and chloride increased linearly with the sweat rate during passive heating (R2 = 0.76 and 0.66, respectively). The device can reliably measure the sweat rate and collect sweat samples for chemical analysis. It can be utilized for real-time physiological investigations toward wider applications.
Collapse
Affiliation(s)
- Tomoaki Ohashi
- Honda Research Institute Japan Co., Ltd., 8-1 Honcho, Wako 351-0188, Japan
| | - Nicola Gerrett
- Laboratory for Applied Human Physiology, Graduate School of Human Development and Environment, Kobe University, 3-11 Tsurukabuto, Nada-ku, Kobe 657-8501, Japan.,Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Van der Boechorststraat 7-9, 1081 BT Amsterdam, The Netherlands
| | - Satoru Shinkawa
- Honda Research Institute Japan Co., Ltd., 8-1 Honcho, Wako 351-0188, Japan
| | - Tomomi Sato
- Microfluidic Integrated Circuits Research Laboratory, Graduate School of Engineering, The University of Tokyo, 7-7 Shinkawasaki, Saiwai-ku, Kawasaki 212-0032, Japan
| | - Ryo Miyake
- Microfluidic Integrated Circuits Research Laboratory, Graduate School of Engineering, The University of Tokyo, 7-7 Shinkawasaki, Saiwai-ku, Kawasaki 212-0032, Japan
| | - Narihiko Kondo
- Laboratory for Applied Human Physiology, Graduate School of Human Development and Environment, Kobe University, 3-11 Tsurukabuto, Nada-ku, Kobe 657-8501, Japan
| | | |
Collapse
|
74
|
Hernández-Rodríguez JF, Rojas D, Escarpa A. Electrochemical Sensing Directions for Next-Generation Healthcare: Trends, Challenges, and Frontiers. Anal Chem 2020; 93:167-183. [PMID: 33174738 DOI: 10.1021/acs.analchem.0c04378] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Juan F Hernández-Rodríguez
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain
| | - Daniel Rojas
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain.,Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, 64100 Teramo, Italy
| | - Alberto Escarpa
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain.,Chemical Research Institute Andres M. del Rio, University of Alcalá, E-28871 Madrid, Spain
| |
Collapse
|