51
|
Roccarina D, Rosselli M, Genesca J, Tsochatzis EA. Elastography methods for the non-invasive assessment of portal hypertension. Expert Rev Gastroenterol Hepatol 2018; 12:155-164. [PMID: 28856972 DOI: 10.1080/17474124.2017.1374852] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The gold standard to assess the presence and severity of portal hypertension remains the hepatic vein pressure gradient, however the recent development of non-invasive assessment using elastography techniques offers valuable alternatives. In this review, we discuss the diagnostic accuracy and utility of such techniques in patients with portal hypertension due to cirrhosis. Areas covered: A literature search focused on liver and spleen stiffness measurement with different elastographic techniques for the assessment of the presence and severity of portal hypertension and oesophageal varices in people with chronic liver disease. The combination of elastography with parameters such as platelet count and spleen size is also discussed. Expert commentary: Non-invasive assessment of liver fibrosis and portal hypertension is a validated tool for the diagnosis and follow-up of patients. Baveno VI recommended the combination of transient elastography and platelet count for ruling out varices needing treatment in patients with compensated advanced chronic liver disease. Assessment of aetiology specific cut-offs for ruling in and ruling out clinically significant portal hypertension is an unmet clinical need. The incorporation of spleen stiffness measurements in non-invasive algorithms using validated software and improved measuring scales might enhance the non-invasive diagnosis of portal hypertension in the next 5 years.
Collapse
Affiliation(s)
- Davide Roccarina
- a UCL Institute for Liver and Digestive Health , Royal Free Hospital and UCL , London , UK
| | - Matteo Rosselli
- a UCL Institute for Liver and Digestive Health , Royal Free Hospital and UCL , London , UK
| | - Joan Genesca
- b Liver Unit, Department of Internal Medicine , Valld'Hebron University Hospital, VHIR, Universitat Autònoma de Barcelona, CIBERehd , Barcelona , Spain
| | - Emmanuel A Tsochatzis
- a UCL Institute for Liver and Digestive Health , Royal Free Hospital and UCL , London , UK
| |
Collapse
|
52
|
Castera L. Liver Stiffness by Ultrasound Elastography. DIAGNOSTIC METHODS FOR CIRRHOSIS AND PORTAL HYPERTENSION 2018:95-111. [DOI: 10.1007/978-3-319-72628-1_7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
|
53
|
Establishing ultrasound based transient elastography cutoffs for different stages of hepatic fibrosis and cirrhosis in Egyptian chronic hepatitis C patients. Arab J Gastroenterol 2017; 18:210-215. [PMID: 29187317 DOI: 10.1016/j.ajg.2017.11.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2017] [Revised: 06/05/2017] [Accepted: 11/12/2017] [Indexed: 12/15/2022]
Abstract
BACKGROUND AND STUDY AIM Transient elastography is widely used to assess fibrosis stage in chronic hepatitis C (CHC). We aimed to establish and validate different transient elastography cut-off values for significant fibrosis and cirrhosis in CHC genotype 4 patients. PATIENTS AND METHODS The data of 100 treatment-naive CHC patients (training set) and 652 patients (validation set) were analysed. The patients were subjected to routine pretreatment laboratory investigations, liver biopsy and histopathological staging of hepatic fibrosis according to the METAVIR scoring system. Transient elastography was performed before and in the same week as liver biopsy using FibroScan (Echosens, Paris, France). Transient elastography results were correlated to different stages of hepatic fibrosis in both the training and validation sets. RESULTS ROC curves were constructed. In the training set, the best transient elastography cut-off values for significant hepatic fibrosis (≥F2 METAVIR), advanced hepatic fibrosis (≥F3 METAVIR) and cirrhosis (F4 METAVIR) were 7.1, 9 and 12.2 kPa, with sensitivities of 87%, 87.5% and 90.9% and specificities of 100%, 99.9% and 99.9%, respectively. The application of these cut-offs in the validation set showed sensitivities of 85.5%, 82.8% and 92% and specificities of 86%, 89.4% and 99.01% for significant hepatic fibrosis, advanced hepatic fibrosis and cirrhosis, respectively. CONCLUSION Transient elastography performs well for significant hepatic fibrosis, advanced hepatic fibrosis and cirrhosis, with validated cut-offs of 7.1, 9 and 12.2 kPa, respectively, in genotype 4 CHC patients.
Collapse
|
54
|
Xiao H, Shi M, Xie Y, Chi X. Comparison of diagnostic accuracy of magnetic resonance elastography and Fibroscan for detecting liver fibrosis in chronic hepatitis B patients: A systematic review and meta-analysis. PLoS One 2017; 12:e0186660. [PMID: 29107943 PMCID: PMC5673175 DOI: 10.1371/journal.pone.0186660] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2017] [Accepted: 10/05/2017] [Indexed: 12/17/2022] Open
Abstract
Aim This systematic review and meta-analysis was carried out to compare the diagnostic accuracy of Magnetic resonance elastography (MRE) and Fibroscan for detecting liver fibrosis in Chronic Hepatitis B (CHB) patients. Methods The PubMed, the Cochrane Library, and the Web of science databases were searched for studies that evaluated the diagnostic value of MRE and Fibroscan for liver fibrosis in CHB patients until March 1st 2017. The quality of the included studies was assessed by the revised Quality Assessment for Studies of Diagnostic Accuracy tool (QUADAS-2). Meta-disc 4.1 was used to summary the area under receiver operating characteristics curve (AUROC), sensitivity, specificity, diagnostic odds ratios to assess the accuracy of staging liver fibrosis using MRE and Fibroscan. Results A total of nine MRE studies with 1470 patients and fifteen Fibroscan studies with 3641 patients were included in this systematic review. The summary AUROC values using MRE and Fibroscan for detecting significant fibrosis, advanced fibrosis and cirrhosis were 0.981 vs. 0.796(p<0.001), 0.972 vs. 0.893(p<0.001), and 0.972 vs. 0.905 (p<0.001). The pooled sensitivity and specificity using MRE for the diagnosis of significant fibrosis, advanced fibrosis and cirrhosis were 92.8% and 93.7%, 89.6% and 93.2%, 89.5% and 92.0%, respectively. The pooled sensitivity and specificity using Fibroscan for the diagnosis of significant fibrosis, advanced fibrosis and cirrhosis were 71.6% and 81.6%, 79.0% and 84.6%, 80.0% and 86.6%, respectively. Conclusion MRE is more accurate than Fibroscan in diagnosing liver fibrosis in CHB patients, especially in diagnosing significant fibrosis and advanced fibrosis.
Collapse
Affiliation(s)
- Huanming Xiao
- Hepatology Department, Guangdong provincial hospital of Chinese Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
| | - Meijie Shi
- Hepatology Department, Guangdong provincial hospital of Chinese Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
- Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
| | - Yubao Xie
- Hepatology Department, Guangdong provincial hospital of Chinese Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
| | - Xiaoling Chi
- Hepatology Department, Guangdong provincial hospital of Chinese Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
- * E-mail:
| |
Collapse
|
55
|
Liver investigations: Updating on US technique and contrast-enhanced ultrasound (CEUS). Eur J Radiol 2017; 96:65-73. [PMID: 29103478 DOI: 10.1016/j.ejrad.2017.08.029] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Revised: 06/15/2017] [Accepted: 08/28/2017] [Indexed: 12/15/2022]
Abstract
Over the past few years, the cross sectional imaging techniques (Computed Tomography - CT and Magnetic Resonance - MR) have improved, allowing a more efficient study of focal and diffuse liver diseases. Many papers had been published about the results of a routinely clinical use of the dual source/dual energy CT techniques and the use of hepatobiliary contrast agents in MR liver studies. As a consequence, these new improvements have diverted the attention away from the Ultrasound technique and its technical and conceptual evolutions. In these years of disinterest, US and especially Contrast Enhanced Ultrasound (CEUS) have consolidated and grown in their application in clinical routine for liver pathologies. In particular, thanks to the introduction of new, dedicated software packages, CEUS has allowed not only qualitative, but also quantitative analysis of lesion microcirculation, thus opening a new era in the evaluation of lesion characterization and response to therapy. Moreover, the renewed interest in liver elastography, a baseline ultrasound-based imaging modality, has led to the development of a competitive technique to assess liver stiffness and then for the evaluation of the progression towards cirrhosis, and characterization of focal liver lesions, opening the way to avoid, in selected cases, liver biopsy. The aim of this review is to offer an up-to-date overview on the state of the art of clinical applications of US and CEUS in the study of focal and diffuse liver pathologies. Besides, it aims to highlight the emerging role of perfusion techniques in the assessment of local and systemic treatment response and to show how the liver evolution from steatosis to fibrosis can be revealed by elastography.
Collapse
|
56
|
Lee ES, Lee JB, Park HR, Yoo J, Choi JI, Lee HW, Kim HJ, Choi BI, Park HJ, Park SB. Shear Wave Liver Elastography with a Propagation Map: Diagnostic Performance and Inter-Observer Correlation for Hepatic Fibrosis in Chronic Hepatitis. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1355-1363. [PMID: 28431795 DOI: 10.1016/j.ultrasmedbio.2017.02.010] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2016] [Revised: 01/12/2017] [Accepted: 02/13/2017] [Indexed: 06/07/2023]
Abstract
The aim of this study was to determine the performance of shear wave elastography (SWE) with a propagation map in the diagnosis of hepatic fibrosis, and to assess its reliability with transient elastography (TE) as the reference standard. Our prospective study included 115 consecutive patients with suspected or alleged chronic hepatitis. Patients underwent SWE by two different operators and TE by sonographers on the same day. The correlation coefficient of the intra-class correlation test between an experienced radiologist and a third-year radiology resident was 0.878. There was a moderate correlation between SWE and TE (r = 0.511) in the diagnosis of hepatic fibrosis. The best cutoff values predicting significant hepatic fibrosis and liver cirrhosis by SWE were >1.78 m/s (area under the receiver operating characteristic curve [AUROC] = 0.777) and >2.24 m/s (AUROC = 0.935), respectively. SWE with a propagation map is a reliable method for predicting hepatic fibrosis regardless of operator experience.
Collapse
Affiliation(s)
- Eun Sun Lee
- Department of Radiology, Chung-Ang University Hospital, Seoul, Republic of Korea; College of Medicine, Chung-Ang University, Seoul, Republic of Korea
| | - Jong Beum Lee
- Department of Radiology, Chung-Ang University Hospital, Seoul, Republic of Korea; College of Medicine, Chung-Ang University, Seoul, Republic of Korea.
| | - Hwi Ryong Park
- Department of Radiology, Chung-Ang University Hospital, Seoul, Republic of Korea; College of Medicine, Chung-Ang University, Seoul, Republic of Korea
| | - Jeongin Yoo
- Department of Radiology, Chung-Ang University Hospital, Seoul, Republic of Korea; College of Medicine, Chung-Ang University, Seoul, Republic of Korea
| | - Ji In Choi
- Department of Radiology, Chung-Ang University Hospital, Seoul, Republic of Korea; College of Medicine, Chung-Ang University, Seoul, Republic of Korea
| | - Hyun Woong Lee
- College of Medicine, Chung-Ang University, Seoul, Republic of Korea; Division of Gastroenterology and Hepatology, Chung-Ang University Hospital, Seoul, Republic of Korea
| | - Hyung Joon Kim
- College of Medicine, Chung-Ang University, Seoul, Republic of Korea; Division of Gastroenterology and Hepatology, Chung-Ang University Hospital, Seoul, Republic of Korea
| | - Byung Ihn Choi
- Department of Radiology, Chung-Ang University Hospital, Seoul, Republic of Korea; College of Medicine, Chung-Ang University, Seoul, Republic of Korea
| | - Hyun Jeong Park
- Department of Radiology, Chung-Ang University Hospital, Seoul, Republic of Korea; College of Medicine, Chung-Ang University, Seoul, Republic of Korea
| | - Sung Bin Park
- Department of Radiology, Chung-Ang University Hospital, Seoul, Republic of Korea; College of Medicine, Chung-Ang University, Seoul, Republic of Korea
| |
Collapse
|
57
|
Pu K, Shi JH, Wang X, Tang Q, Wang XJ, Tang KL, Long ZQ, Hu XS. Diagnostic accuracy of transient elastography (FibroScan) in detection of esophageal varices in patients with cirrhosis: A meta-analysis. World J Gastroenterol 2017; 23:345-356. [PMID: 28127208 PMCID: PMC5236514 DOI: 10.3748/wjg.v23.i2.345] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2016] [Revised: 09/29/2016] [Accepted: 10/31/2016] [Indexed: 02/06/2023] Open
Abstract
AIM To investigate the diagnostic accuracy of FibroScan (FS) in detecting esophageal varices (EV) in cirrhotic patients.
METHODS Through a systemic literature search of multiple databases, we reviewed 15 studies using endoscopy as a reference standard, with the data necessary to calculate pooled sensitivity (SEN) and specificity (SPE), positive and negative LR, diagnostic odds ratio (DOR) and area under receiver operating characteristics (AUROC). The quality of the studies was rated by the Quality Assessment of Diagnostic Accuracy studies-2 tool. Clinical utility of FS for EV was evaluated by a Fagan plot. Heterogeneity was explored using meta-regression and subgroup analysis. All statistical analyses were conducted via Stata12.0, MetaDisc1.4 and RevMan5.
RESULTS In 15 studies (n = 2697), FS detected the presence of EV with the summary sensitivities of 84% (95%CI: 81.0%-86.0%), specificities of 62% (95%CI: 58.0%- 66.0%), a positive LR of 2.3 (95%CI: 1.81-2.94), a negative LR of 0.26 (95%CI: 0.19-0.35), a DOR of 9.33 (95%CI: 5.84-14.92) and an AUROC of 0.8262. FS diagnosed the presence of large EV with the pooled SEN of 0.78 (95%CI: 75.0%-81.0%), SPE of 0.76 (95%CI: 73.0%-78.0%), a positive and negative LR of 3.03 (95%CI: 2.38-3.86) and 0.30 (95%CI: 0.23-0.39) respectively, a summary diagnostic OR of 10.69 (95%CI: 6.81-16.78), and an AUROC of 0.8321. A meta-regression and subgroup analysis indicated different etiology could serve as a potential source of heterogeneity in the diagnosis of the presence of EV group. A Deek’s funnel plot suggested a low probability for publication bias.
CONCLUSION Using FS to measure liver stiffness cannot provide high accuracy for the size of EV due to the various cutoff and different etiologies. These limitations preclude widespread use in clinical practice at this time; therefore, the results should be interpreted cautiously given its SEN and SPE.
Collapse
|
58
|
You MW, Kim KW, Pyo J, Huh J, Kim HJ, Lee SJ, Park SH. A Meta-analysis for the Diagnostic Performance of Transient Elastography for Clinically Significant Portal Hypertension. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:59-68. [PMID: 27751595 DOI: 10.1016/j.ultrasmedbio.2016.07.025] [Citation(s) in RCA: 78] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2015] [Revised: 07/18/2016] [Accepted: 07/31/2016] [Indexed: 06/06/2023]
Abstract
We aimed to evaluate the correlation between liver stiffness measurement using transient elastography (TE-LSM) and hepatic venous pressure gradient and the diagnostic performance of TE-LSM in assessing clinically significant portal hypertension through meta-analysis. Eleven studies were included from thorough literature research and selection processes. The summary correlation coefficient was 0.783 (95% confidence interval [CI], 0.737-0.823). Summary sensitivity, specificity and area under the hierarchical summary receiver operating characteristic curve (AUC) were 87.5% (95% CI, 75.8-93.9%), 85.3 % (95% CI, 76.9-90.9%) and 0.9, respectively. The subgroup with low cut-off values of 13.6-18 kPa had better summary estimates (sensitivity 91.2%, specificity 81.3% and partial AUC 0.921) than the subgroup with high cut-off values of 21-25 kPa (sensitivity 71.2%, specificity 90.9% and partial AUC 0.769). In summary, TE-LSM correlated well with hepatic venous pressure gradient and represented good diagnostic performance in diagnosing clinically significant portal hypertension. For use as a sensitive screening tool, we propose using low cut-off values of 13.6-18 kPa in TE-LSM.
Collapse
Affiliation(s)
- Myung-Won You
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Kyung Won Kim
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea; Asan Liver Center, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
| | - Junhee Pyo
- WHO Collaborating Center for Pharmaceutical Policy and Regulation, Department of Pharmaceutical Science, Utrecht University, Netherlands
| | - Jimi Huh
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Hyoung Jung Kim
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea; Asan Liver Center, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - So Jung Lee
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea; Asan Liver Center, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Seong Ho Park
- Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
59
|
Persico M, Rosato V, Aglitti A, Precone D, Corrado M, De Luna A, Morisco F, Camera S, Federico A, Dallio M, Claar E, Caporaso N, Masarone M. Sustained virological response by direct antiviral agents in HCV leads to an early and significant improvement of liver fibrosis. Antivir Ther 2017; 23:129-138. [DOI: 10.3851/imp3186] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/31/2017] [Indexed: 10/19/2022]
|
60
|
Knop V, Hoppe D, Welzel T, Vermehren J, Herrmann E, Vermehren A, Friedrich-Rust M, Sarrazin C, Zeuzem S, Welker MW. Regression of fibrosis and portal hypertension in HCV-associated cirrhosis and sustained virologic response after interferon-free antiviral therapy. J Viral Hepat 2016; 23:994-1002. [PMID: 27500382 DOI: 10.1111/jvh.12578] [Citation(s) in RCA: 127] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2016] [Accepted: 07/07/2016] [Indexed: 02/06/2023]
Abstract
It is still controversial, whether and to what amount cirrhosis and portal hypertension are reversible in patients with hepatitis C virus (HCV)-associated cirrhosis and sustained virologic response (SVR) after interferon-free antiviral therapy. In this study, we prospectively evaluated dynamics of liver and spleen stiffness in HCV-infected patients with advanced liver disease and SVR after interferon-free treatment. A total of 54 patients with HCV-associated cirrhosis and SVR were included. Liver and spleen stiffness was measured at therapy baseline (BL), end of treatment (EOT) and 24 weeks after EOT (FU24) by transient liver elastography (L-TE) as well as by acoustic radiation force impulse of the liver (L-ARFI) and spleen (S-ARFI), as well as biochemical, virologic and clinical data. Improvement of liver and spleen stiffness was found in 44 of 50 (88%), 31 of 54 (57%) and 25 of 54 (46%) of patients assessed by L-TE, L-ARFI and S-ARFI between baseline and FU24. Liver stiffness assessed by L-TE improved between BL [median (range), 32.5 (9.1-75) kPa] and EOT [median (range), 21.3 (6.7-73.5) kPa; (P<.0001)], and between BL and FU24 [median (range), 21.2 (5.4-70) kPa; (P<.0001)]. Liver stiffness assessed by L-ARFI improved between BL [median (range), 2.7 (1.2-4.1) m/s] and FU24 [median (range), 2.4 (1.2-3.9) m/s; P=.002), while spleen stiffness remained unchanged. Our data suggest that improvement of liver stiffness may be rather due to reduced necroinflammation and may be due to a less extent to regression of cirrhosis, as dynamics of liver stiffness improvement was more pronounced between BL and EOT than BL and FU24.
Collapse
Affiliation(s)
- V Knop
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - D Hoppe
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - T Welzel
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - J Vermehren
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - E Herrmann
- Institut für Biostatistik und mathematische Modellierung, Goethe-Universität Frankfurt, Frankfurt am Main, Germany
| | - A Vermehren
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - M Friedrich-Rust
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - C Sarrazin
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - S Zeuzem
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - M-W Welker
- Medizinische Klinik 1, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| |
Collapse
|
61
|
Shan QY, Liu BX, Tian WS, Wang W, Zhou LY, Wang Y, Xie XY. Elastography of shear wave speed imaging for the evaluation of liver fibrosis: A meta-analysis. Hepatol Res 2016; 46:1203-1213. [PMID: 26857658 DOI: 10.1111/hepr.12669] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2015] [Revised: 01/24/2016] [Accepted: 02/04/2016] [Indexed: 01/01/2023]
Abstract
AIM A meta-analysis was carried out to assess the accuracies of shear wave speed imaging (SWSI) in predicting significant fibrosis (stages F2-4) and cirrhosis (stage F4). METHODS A review was performed of relevant studies published until October 2015. A bivariate binomial model was used to combine the sensitivity, specificity, and the area under the summary receiver operating characteristic (AUC), and 95% confidence intervals were derived to indicate the diagnostic accuracy of imaging modalities. RESULTS In total, 10 studies with 2182 patients were included in the analysis. The sensitivity, specificity, and AUC (with 95% confidence intervals) of SWSI were: 0.84 (0.81-0.87), 0.83 (0.77-0.88), and 0.88 (0.85-0.90) for significant fibrosis, respectively; and 0.80 (0.66-0.89), 0.93 (0.88-0.96), and 0.95 (0.92-0.96) for cirrhosis, respectively. When SWSI was compared with well-evaluated transient elastography, the AUCs for the prediction of significant fibrosis were 0.93 and 0.86, respectively. The AUCs for the prediction of cirrhosis were both 0.94. CONCLUSION Shear wave speed imaging is a trustworthy tool for staging hepatic fibrosis, with a high combination of sensitivity and specificity. Compared with transient elastography, SWSI showed better diagnostic performance for the prediction of significant fibrosis.
Collapse
Affiliation(s)
- Quan-Yuan Shan
- Institute of Diagnostic and Interventional Ultrasound, Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Sun Yat-Sen University, Guangzhou, China
| | - Bao-Xian Liu
- Institute of Diagnostic and Interventional Ultrasound, Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Sun Yat-Sen University, Guangzhou, China
| | - Wen-Shuo Tian
- Institute of Diagnostic and Interventional Ultrasound, Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Sun Yat-Sen University, Guangzhou, China
| | - Wei Wang
- Institute of Diagnostic and Interventional Ultrasound, Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Sun Yat-Sen University, Guangzhou, China
| | - Lu-Yao Zhou
- Institute of Diagnostic and Interventional Ultrasound, Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Sun Yat-Sen University, Guangzhou, China
| | - Yan Wang
- Institute of Diagnostic and Interventional Ultrasound, Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Sun Yat-Sen University, Guangzhou, China
| | - Xiao-Yan Xie
- Institute of Diagnostic and Interventional Ultrasound, Department of Medical Ultrasonics, The First Affiliated Hospital of Sun Yat-sen University, Sun Yat-Sen University, Guangzhou, China
| |
Collapse
|
62
|
Montano-Loza AJ, Thandassery RB, Czaja AJ. Targeting Hepatic Fibrosis in Autoimmune Hepatitis. Dig Dis Sci 2016; 61:3118-3139. [PMID: 27435327 DOI: 10.1007/s10620-016-4254-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2016] [Accepted: 07/11/2016] [Indexed: 02/06/2023]
Abstract
Hepatic fibrosis develops or progresses in 25 % of patients with autoimmune hepatitis despite corticosteroid therapy. Current management regimens lack reliable noninvasive methods to assess changes in hepatic fibrosis and interventions that disrupt fibrotic pathways. The goals of this review are to indicate promising noninvasive methods to monitor hepatic fibrosis in autoimmune hepatitis and identify anti-fibrotic interventions that warrant evaluation. Laboratory methods can differentiate cirrhosis from non-cirrhosis, but their accuracy in distinguishing changes in histological stage is uncertain. Radiological methods include transient elastography, acoustic radiation force impulse imaging, and magnetic resonance elastography. Methods based on ultrasonography are comparable in detecting advanced fibrosis and cirrhosis, but their performances may be compromised by hepatic inflammation and obesity. Magnetic resonance elastography has excellent performance parameters for all histological stages in diverse liver diseases, is uninfluenced by inflammatory activity or body habitus, has been superior to other radiological methods in nonalcoholic fatty liver disease, and may emerge as the preferred instrument to evaluate fibrosis in autoimmune hepatitis. Promising anti-fibrotic interventions are site- and organelle-specific agents, especially inhibitors of nicotinamide adenine dinucleotide phosphate oxidases, transforming growth factor beta, inducible nitric oxide synthase, lysyl oxidases, and C-C chemokine receptors types 2 and 5. Autoimmune hepatitis has a pro-fibrotic propensity, and noninvasive radiological methods, especially magnetic resonance elastography, and site- and organelle-specific interventions, especially selective antioxidants and inhibitors of collagen cross-linkage, may emerge to strengthen current management strategies.
Collapse
Affiliation(s)
- Aldo J Montano-Loza
- Division of Gastroenterology and Liver Unit, University of Alberta Hospital, Edmonton, AB, Canada
| | - Ragesh B Thandassery
- Division of Gastroenterology and Liver Unit, University of Alberta Hospital, Edmonton, AB, Canada
| | - Albert J Czaja
- Professor Emeritus of Medicine, Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, 200 First Street S.W., Rochester, MN, 55905, USA.
| |
Collapse
|
63
|
Giunta M, Conte D, Fraquelli M. Role of spleen elastography in patients with chronic liver diseases. World J Gastroenterol 2016; 22:7857-7867. [PMID: 27672283 PMCID: PMC5028802 DOI: 10.3748/wjg.v22.i35.7857] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2016] [Revised: 08/16/2016] [Accepted: 08/30/2016] [Indexed: 02/06/2023] Open
Abstract
The development of liver cirrhosis and portal hypertension (PH), one of its major complications, are structural and functional alterations of the liver, occurring in many patients with chronic liver diseases (CLD). Actually the progressive deposition of hepatic fibrosis has a key role in the prognosis of CLD patients. The subsequent development of PH leads to its major complications, such as ascites, hepatic encephalopathy, variceal bleeding and decompensation. Liver biopsy is still considered the reference standard for the assessment of hepatic fibrosis, whereas the measurement of hepatic vein pressure gradient is the standard to ascertain the presence of PH and upper endoscopy is the method of choice to detect the presence of oesophageal varices. However, several non-invasive tests, including elastographic techniques, are currently used to evaluate the severity of liver disease and predict its prognosis. More recently, the measurement of the spleen stiffness has become particularly attractive to assess, considering the relevant role accomplished by the spleen in splanchnic circulation in the course of liver cirrhosis and in the PH. Moreover, spleen stiffness as compared with liver stiffness better represents the dynamic changes occurring in the advanced stages of cirrhosis and shows higher diagnostic performance in detecting esophageal varices. The aim of this review is to provide an exhaustive overview of the actual role of spleen stiffness measurement as assessed by several elastographic techniques in evaluating both liver disease severity and the development of cirrhosis complications, such as PH and to highlight its potential and possible limitations.
Collapse
|
64
|
Smith AD, Branch CR, Zand K, Subramony C, Zhang H, Thaggard K, Hosch R, Bryan J, Vasanji A, Griswold M, Zhang X. Liver Surface Nodularity Quantification from Routine CT Images as a Biomarker for Detection and Evaluation of Cirrhosis. Radiology 2016; 280:771-81. [DOI: 10.1148/radiol.2016151542] [Citation(s) in RCA: 75] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
65
|
Abdel Latif M, Shady M, Nabil H, Mesbah Y. Trans-vaginal sono-elastography in the differentiation of endometrial hyperplasia and endometrial carcinoma. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2016. [DOI: 10.1016/j.ejrnm.2016.04.021] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
|
66
|
Yoo H, Lee JM, Yoon JH, Lee DH, Chang W, Han JK. Prospective Comparison of Liver Stiffness Measurements between Two Point Shear Wave Elastography Methods: Virtual Touch Quantification and Elastography Point Quantification. Korean J Radiol 2016; 17:750-7. [PMID: 27587964 PMCID: PMC5007402 DOI: 10.3348/kjr.2016.17.5.750] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2016] [Accepted: 06/24/2016] [Indexed: 12/12/2022] Open
Abstract
Objective To prospectively compare technical success rate and reliable measurements of virtual touch quantification (VTQ) elastography and elastography point quantification (ElastPQ), and to correlate liver stiffness (LS) measurements obtained by the two elastography techniques. Materials and Methods Our study included 85 patients, 80 of whom were previously diagnosed with chronic liver disease. The technical success rate and reliable measurements of the two kinds of point shear wave elastography (pSWE) techniques were compared by χ2 analysis. LS values measured using the two techniques were compared and correlated via Wilcoxon signed-rank test, Spearman correlation coefficient, and 95% Bland-Altman limit of agreement. The intraobserver reproducibility of ElastPQ was determined by 95% Bland-Altman limit of agreement and intraclass correlation coefficient (ICC). Results The two pSWE techniques showed similar technical success rate (98.8% for VTQ vs. 95.3% for ElastPQ, p = 0.823) and reliable LS measurements (95.3% for VTQ vs. 90.6% for ElastPQ, p = 0.509). The mean LS measurements obtained by VTQ (1.71 ± 0.47 m/s) and ElastPQ (1.66 ± 0.41 m/s) were not significantly different (p = 0.209). The LS measurements obtained by the two techniques showed strong correlation (r = 0.820); in addition, the 95% limit of agreement of the two methods was 27.5% of the mean. Finally, the ICC of repeat ElastPQ measurements was 0.991. Conclusion Virtual touch quantification and ElastPQ showed similar technical success rate and reliable measurements, with strongly correlated LS measurements. However, the two methods are not interchangeable due to the large limit of agreement.
Collapse
Affiliation(s)
- Hyunsuk Yoo
- Department of Radiology, Seoul National University Hospital, Seoul 03080, Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul 03080, Korea.; Institute of Radiation Medicine, Seoul National University Hospital, Seoul 03080, Korea
| | - Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, Seoul 03080, Korea
| | - Dong Ho Lee
- Department of Radiology, Seoul National University Hospital, Seoul 03080, Korea
| | - Won Chang
- Department of Radiology, Seoul National University Hospital, Seoul 03080, Korea
| | - Joon Koo Han
- Department of Radiology, Seoul National University Hospital, Seoul 03080, Korea.; Institute of Radiation Medicine, Seoul National University Hospital, Seoul 03080, Korea
| |
Collapse
|
67
|
Hull M, Shafran S, Wong A, Tseng A, Giguère P, Barrett L, Haider S, Conway B, Klein M, Cooper C. CIHR Canadian HIV Trials Network Coinfection and Concurrent Diseases Core Research Group: 2016 Updated Canadian HIV/Hepatitis C Adult Guidelines for Management and Treatment. THE CANADIAN JOURNAL OF INFECTIOUS DISEASES & MEDICAL MICROBIOLOGY = JOURNAL CANADIEN DES MALADIES INFECTIEUSES ET DE LA MICROBIOLOGIE MEDICALE 2016; 2016:4385643. [PMID: 27471521 PMCID: PMC4947683 DOI: 10.1155/2016/4385643] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 09/25/2015] [Accepted: 12/15/2015] [Indexed: 12/13/2022]
Abstract
Background. Hepatitis C virus (HCV) coinfection occurs in 20-30% of Canadians living with HIV and is responsible for a heavy burden of morbidity and mortality. Purpose. To update national standards for management of HCV-HIV coinfected adults in the Canadian context with evolving evidence for and accessibility of effective and tolerable DAA therapies. The document addresses patient workup and treatment preparation, antiviral recommendations overall and in specific populations, and drug-drug interactions. Methods. A standing working group with HIV-HCV expertise was convened by The Canadian Institute of Health Research HIV Trials Network to review recently published HCV antiviral data and update Canadian HIV-HCV Coinfection Guidelines. Results. The gap in sustained virologic response between HCV monoinfection and HIV-HCV coinfection has been eliminated with newer HCV antiviral regimens. All coinfected individuals should be assessed for interferon-free, Direct Acting Antiviral HCV therapy. Regimens vary in content, duration, and success based largely on genotype. Reimbursement restrictions forcing the use of pegylated interferon is not acceptable if optimal patient care is to be provided. Discussion. Recommendations may not supersede individual clinical judgement. Treatment advances published since December 2015 are not considered in this document.
Collapse
Affiliation(s)
- Mark Hull
- British Columbia Centre for Excellence in HIV/AIDS, University of British Columbia, Vancouver, BC, Canada V6T 1Z4
| | | | - Alex Wong
- Regina Qu'Appelle Health Region, Regina, SK, Canada S4P 1E2
| | - Alice Tseng
- Toronto General Hospital, Toronto, ON, Canada M5G 2C4
| | | | - Lisa Barrett
- Dalhousie University, Halifax, NS, Canada B3H 4R2
| | | | - Brian Conway
- Vancouver Infectious Diseases Centre, Vancouver, BC, Canada V6Z 2C7
| | | | - Curtis Cooper
- The Ottawa Hospital, General Campus, G12, 501 Smyth Road, Ottawa, ON, Canada K1H 8L6
| |
Collapse
|
68
|
Friedrich-Rust M, Poynard T, Castera L. Critical comparison of elastography methods to assess chronic liver disease. Nat Rev Gastroenterol Hepatol 2016; 13:402-11. [PMID: 27273167 DOI: 10.1038/nrgastro.2016.86] [Citation(s) in RCA: 181] [Impact Index Per Article: 20.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Staging of liver fibrosis and diagnosis, or exclusion, of early compensated liver cirrhosis are important in the treatment decisions and surveillance of patients with chronic liver disease. Good diagnostic accuracy, increased availability and the possibility to perform follow-up examinations led to the implementation of noninvasive methods into clinical practice. Noninvasive tests are increasingly included in national and international guidelines, leaving liver biopsy reserved for patients with unexplained discordance or suspected additional aetiologies of liver disease. In addition to staging of liver fibrosis, data on the prognostic value of these methods have increased in the past few years and are of great importance for patient care. This Review focuses on elastography methods for noninvasive assessment of liver fibrosis, disease severity and prognosis. Although liver elastography started with transient elastography, at present all large ultrasonography companies offer an elastography technique integrated in their machines. The goal of this Review is to summarize the methodological problems of noninvasive tests in general, in addition to providing an overview on currently available techniques and latest developments in liver elastography.
Collapse
Affiliation(s)
- Mireen Friedrich-Rust
- Department of Internal Medicine, J.W. Goethe-University Hospital, Theodor-Stern-Kai 7, Frankfurt 60590, Germany
| | - Thierry Poynard
- Assistance Publique-Hôpitaux de Paris, Hôpital Pitié-Salpêtrière, Hepatology Department, 47-83 Boulevard de l'Hôpital, Paris 75013, France.,Université Pierre et Marie Curie, INSERM, UMR-S 938, 57 Boulevard de l'Hôpital, Paris 75013, France
| | - Laurent Castera
- Department of Hepatology, Hôpital Beaujon, Assistance Publique-Hôpitaux de Paris, 100 Boulevard du General Leclerc, Clichy 92110, France.,Université Paris VII, INSERM UMR 1149, Centre de Recherche sur l'Inflammation, 16 Rue Huchard, Paris 75018, France
| |
Collapse
|
69
|
Geng XX, Huang RG, Lin JM, Jiang N, Yang XX. Transient elastography in clinical detection of liver cirrhosis: A systematic review and meta-analysis. Saudi J Gastroenterol 2016; 22:294-303. [PMID: 27488324 PMCID: PMC4991200 DOI: 10.4103/1319-3767.187603] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2015] [Accepted: 02/27/2016] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND/AIMS Transient elastography is a noninvasive method for measuring liver fibrosis. This meta-analysis assesses the diagnostic performance of transient elastography of detecting liver cirrhosis in patients with liver disease. PATIENTS AND METHODS We searched MEDLINE, Cochrane, EMBASE databases until Jan 31, 2015, using the following search terms: elastography and liver cirrhosis. Included studies assessed patients with a diagnosis of liver cirrhosis, with an index test of transient elastography, and with the reference standard being a histopathological exam by liver biopsy. Sensitivity analysis and assessment of risk of bias and publication bias were performed. RESULTS Fifty-seven studies were included in the meta-analysis with a total of 10,504 patients. The pooled estimate for the sensitivity of transient elastography for detecting liver fibrosis was 81% and the specificity was 88%. The imputed diagnostic odds ratio (DOR) was 26.08 and the area under the receiver-operating characteristic (AUROC) curve was 0.931. CONCLUSION Our findings indicate that transient elastography shows good sensitivity, specificity and a high accuracy for detecting liver cirrhosis. Transient elastography can be used as an additional method for the clinical diagnosis of liver fibrosis and cirrhosis.
Collapse
Affiliation(s)
- Xiao-Xia Geng
- Department of Infectious Diseases, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu 610072, Sichuan Province, China
| | - Ren-Gang Huang
- Department of Infectious Diseases, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu 610072, Sichuan Province, China
| | - Jian-Mei Lin
- Department of Infectious Diseases, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu 610072, Sichuan Province, China
| | - Nan Jiang
- Department of Infectious Diseases, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu 610072, Sichuan Province, China
| | - Xing-Xiang Yang
- Department of Infectious Diseases, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu 610072, Sichuan Province, China
| |
Collapse
|
70
|
Abstract
Over the past decade, several advances have been made in the non-invasive assessment of liver fibrosis. Both serum markers and imaging-based tissue elastography predict the presence of advanced fibrosis compared with liver biopsy. Serum markers may be indirect or direct markers of liver structure and function. Imaging-based techniques measure liver stiffness as a surrogate for fibrosis and include ultrasound and MRI-based methods. Most non-invasive techniques work well at identifying subjects at the extremes of fibrosis but may not accurately discern intermediate stages. In addition to being a diagnostic tool, elastography may have an evolving role in prognosis. Increasing stiffness is associated with higher rates of liver decompensation, need for transplantation, hepatocellular carcinoma, and death. There are special populations of patients where elastography may serve as a non-invasive method to impart useful clinical information, such as patients after liver transplantation, those with congenital heart disease and those being treated for chronic viral hepatitis. The role of non-invasive markers in accurately predicting the presence of fibrosis in obese patients needs to be further refined.
Collapse
Affiliation(s)
- Michael Hagan
- a 1 Baylor University Medical Center, Dallas, TX, USA
| | | | - Jayant Talwalkar
- b 2 Division of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Rochester, MN, USA
| |
Collapse
|
71
|
Chin JL, Pavlides M, Moolla A, Ryan JD. Non-invasive Markers of Liver Fibrosis: Adjuncts or Alternatives to Liver Biopsy? Front Pharmacol 2016; 7:159. [PMID: 27378924 PMCID: PMC4913110 DOI: 10.3389/fphar.2016.00159] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2016] [Accepted: 05/31/2016] [Indexed: 12/13/2022] Open
Abstract
Liver fibrosis reflects sustained liver injury often from multiple, simultaneous factors. Whilst the presence of mild fibrosis on biopsy can be a reassuring finding, the identification of advanced fibrosis is critical to the management of patients with chronic liver disease. This necessity has lead to a reliance on liver biopsy which itself is an imperfect test and poorly accepted by patients. The development of robust tools to non-invasively assess liver fibrosis has dramatically enhanced clinical decision making in patients with chronic liver disease, allowing a rapid and informed judgment of disease stage and prognosis. Should a liver biopsy be required, the appropriateness is clearer and the diagnostic yield is greater with the use of these adjuncts. While a number of non-invasive liver fibrosis markers are now used in routine practice, a steady stream of innovative approaches exists. With improvement in the reliability, reproducibility and feasibility of these markers, their potential role in disease management is increasing. Moreover, their adoption into clinical trials as outcome measures reflects their validity and dynamic nature. This review will summarize and appraise the current and novel non-invasive markers of liver fibrosis, both blood and imaging based, and look at their prospective application in everyday clinical care.
Collapse
Affiliation(s)
- Jun L Chin
- School of Medicine and Medical Science, University College Dublin Dublin, Ireland
| | - Michael Pavlides
- Oxford Centre for Clinical Magnetic Resonance Research, University of Oxford Oxford, UK
| | - Ahmad Moolla
- Radcliffe Department of Medicine, University of Oxford Oxford, UK
| | - John D Ryan
- Translational Gastroenterology Unit, University of Oxford Oxford, UK
| |
Collapse
|
72
|
Huang R, Jiang N, Yang R, Geng X, Lin J, Xu G, Liu D, Chen J, Zhou G, Wang S, Luo T, Wu J, Liu X, Xu K, Yang X. Fibroscan improves the diagnosis sensitivity of liver fibrosis in patients with chronic hepatitis B. Exp Ther Med 2016; 11:1673-1677. [PMID: 27168788 PMCID: PMC4840545 DOI: 10.3892/etm.2016.3135] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2014] [Accepted: 10/22/2015] [Indexed: 12/12/2022] Open
Abstract
The aim of the present study was to investigate the diagnostic accuracy of Fibroscan for liver fibrosis in patients with chronic hepatitis B (CHB) with alanine aminotransferase (ALT) levels <2 times the upper normal limit. A total of 263 consecutive patients with CHB and ALT levels <2 times the upper normal limit were enrolled in the present study. Liver biopsies and liver stiffness measurements (LSM) were conducted. Receiver operating characteristic (ROC) analysis was used to determine the predictive ability of LSM for the development of liver fibrosis in patients with stage S1, S2 and S3 liver fibrosis. Bivariate Spearman rank correlation analysis was performed in order to determine the association between liver stiffness value, which was measured by Fibroscan, and liver fibrosis stage, which was measured by liver biopsy. The liver stiffness value was found to be positively correlated with the liver fibrosis stage (r=0.522, P<0.001) and necroinflammatory activity (r=0.461, P<0.001), which was measured by liver biopsy. The optimal cut-off value in the patients with stage S1, S2 and S3 liver fibrosis was 5.5, 8.0 and 10.95 kPa, respectively. The area under the ROC curve for the prediction of the development of liver fibrosis in these patients was 0.696, 0.911 and 0.923, respectively. The threshold of the optimal cut-off value exhibited a high sensitivity and specificity. The results of the present study suggested that Fibroscan may improve the sensitivity of the diagnosis of liver fibrosis in patients with CHB and ALT levels <2 times the upper normal limit, and that this sensitivity may increase with the progression of liver fibrosis.
Collapse
Affiliation(s)
- Rengang Huang
- Department of Infectious Disease, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| | - Nan Jiang
- Department of Infectious Disease, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| | - Renguo Yang
- Department of Infectious Disease, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| | - Xiaoxia Geng
- Department of Infectious Disease, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| | - Jianmei Lin
- Department of Infectious Disease, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| | - Gang Xu
- Department of Pathology, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| | - Dandan Liu
- Department of Pathology, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| | - Jidog Chen
- Department of Medical Ultrasonics, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| | - Guo Zhou
- Department of Medical Ultrasonics, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| | - Shuqiang Wang
- Department of Infectious Disease, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| | - Tingting Luo
- Department of Infectious Disease, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| | - Jiazhen Wu
- Department of Infectious Disease, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| | - Xiaoshu Liu
- Department of Infectious Disease, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| | - Kaiju Xu
- Department of Infectious Disease, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| | - Xingxiang Yang
- Department of Infectious Disease, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan 610072, P.R. China
| |
Collapse
|
73
|
Hukkinen M, Kivisaari R, Lohi J, Heikkilä P, Mutanen A, Merras-Salmio L, Pakarinen MP. Transient elastography and aspartate aminotransferase to platelet ratio predict liver injury in paediatric intestinal failure. Liver Int 2016; 36:361-9. [PMID: 26058319 DOI: 10.1111/liv.12887] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2015] [Accepted: 06/01/2015] [Indexed: 12/14/2022]
Abstract
BACKGROUND & AIMS We aimed to evaluate the value of AST to platelet ratio (APRI) and transient elastography (TE) as predictors of liver histopathology in children with intestinal failure (IF). METHODS Altogether 93 liver biopsies from 57 children with parenteral nutrition (PN) duration ≥3 months were analysed. APRI measurement and TE (n = 46) were performed at the time of biopsy. RESULTS IF was caused by short bowel syndrome in 75% of patients. At the time of liver biopsy, PN dependent patients (n = 42) were younger with longer PN duration compared to those weaned off PN (n = 51) (2.2 vs. 7.6 years, P < 0.001; 26 vs. 10.5 months, P = 0.043). Elevated transaminase or bilirubin levels were found in 51%, splenomegaly in 26%, and oesophageal varices in 3.5%. Histological fibrosis was present in 61% (Metavir stage F1; 27%, F2; 26%, F3-4; 9%), cholestasis in 25% and steatosis in 22% of biopsy specimens. TE was superior to APRI in prediction of any liver histopathology (fibrosis, cholestasis or steatosis) with areas under the receiving operating curve (AUROC) of 0.86 (95% CI 0.74-0.97) and 0.67 (95% CI 0.58-0.78) respectively. For prediction of ≥F1 and ≥F2 fibrosis, AUROC values for TE were 0.78 (95% CI 0.64-0.93) and 0.73 (95% CI 0.59-0.88), whereas APRI did not correlate with fibrosis stages. For detection of histological cholestasis, the AUROC for APRI was 0.77 (95% CI 0.64-0.89). CONCLUSIONS Both TE and APRI are promising noninvasive methods for monitoring the development of IF-related liver histopathology. TE values reflected the degree of fibrosis better while APRI detected histological cholestasis more accurately.
Collapse
Affiliation(s)
- Maria Hukkinen
- Pediatric Liver and Gut Research Group, Children's Hospital, Helsinki University Hospital, University of Helsinki, Helsinki, Finland
| | - Reetta Kivisaari
- HUS Medical Imaging Center, Children's Hospital, Helsinki University Hospital, University of Helsinki, Helsinki, Finland
| | - Jouko Lohi
- Department of Pathology, HUSLAB, Helsinki University Hospital, University of Helsinki, Helsinki, Finland
| | - Päivi Heikkilä
- Department of Pathology, HUSLAB, Helsinki University Hospital, University of Helsinki, Helsinki, Finland
| | - Annika Mutanen
- Pediatric Liver and Gut Research Group, Children's Hospital, Helsinki University Hospital, University of Helsinki, Helsinki, Finland.,Section of Pediatric Surgery, Children's Hospital, Helsinki University Hospital, University of Helsinki, Helsinki, Finland
| | - Laura Merras-Salmio
- Pediatric Liver and Gut Research Group, Children's Hospital, Helsinki University Hospital, University of Helsinki, Helsinki, Finland.,Section of Pediatric Gastroenterology, Children's Hospital, Helsinki University Hospital, University of Helsinki, Helsinki, Finland
| | - Mikko P Pakarinen
- Pediatric Liver and Gut Research Group, Children's Hospital, Helsinki University Hospital, University of Helsinki, Helsinki, Finland.,Section of Pediatric Surgery, Children's Hospital, Helsinki University Hospital, University of Helsinki, Helsinki, Finland
| |
Collapse
|
74
|
El Saadany S, Soliman H, Ziada DH, Hamisa M, Hefeda M, Selim A, Goraba H. Fibroscan versus liver biopsy in the evaluation of response among the Egyptian HCV infected patients to treatment. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2016. [DOI: 10.1016/j.ejrnm.2015.12.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
|
75
|
Chang W, Lee JM, Yoon JH, Han JK, Choi BI, Yoon JH, Lee KB, Lee KW, Yi NJ, Suh KS. Liver Fibrosis Staging with MR Elastography: Comparison of Diagnostic Performance between Patients with Chronic Hepatitis B and Those with Other Etiologic Causes. Radiology 2016; 280:88-97. [PMID: 26844364 DOI: 10.1148/radiol.2016150397] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Purpose To evaluate the diagnostic performance of magnetic resonance (MR) elastography in staging liver fibrosis in patients with chronic hepatitis B (CHB) and other etiologic causes. Materials and Methods This retrospective study was institutional review board-approved and the requirement for informed consent was waived. Before surgery, MR elastographic imaging was performed in 352 patients with chronic liver diseases (281 patients with CHB, 71 patients without CHB) and hepatocellular carcinomas and 64 living liver donor candidates. Liver stiffness (LS) values were measured on quantitative shear-stiffness maps of MR elastography, and the diagnostic performance of MR elastography in staging liver fibrosis was evaluated by using receiver operating characteristic curve analysis and the Obuchowski measure with the histopathologic analysis of liver fibrosis in the CHB group and in the group composed of other etiologic causes. In 120 patients (97 with CHB, 23 without CHB) and 51 donors, diagnostic performance of MR elastography was validated. Results Areas under the curve of LS values for the diagnosis of significant fibrosis (≥stage F2), severe fibrosis (≥stage F3), and cirrhosis (stage F4) in the CHB group were 0.972 (95% confidence interval: 0.948, 0.987), 0.946 (95% confidence interval: 0.916, 0.968), and 0.920 (95% confidence interval: 0.885, 0.947), respectively. Obuchowski measures were similarly high in the CHB group and in the group composed of other etiologic causes (0.970 vs 0.977). However, the estimated cutoff value for stage F4 in the group with CHB was substantially lower than in the participants with other etiologic causes: 3.67 kPa versus 4.65 kPa. In the validation study for stage F1 or greater, stage F2 or greater, stage F3 or greater, and stage F4, the Youden indexes were 0.807, 0.842, 0.806, and 0.639, respectively, in the group with CHB, and 0.783, 0.900, 1.000, and 0.917, respectively, in the group without CHB. Conclusion The diagnostic performance of MR elastography in liver fibrosis staging was similarly high in the groups with and without CHB, but the cutoff LS values for diagnosing liver cirrhosis differed between the groups with and without CHB. (©) RSNA, 2016 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Won Chang
- From the Departments of Radiology (W.C., J.M.L., Jeong Hee Yoon, J.K.H., B.I.C.), Internal Medicine (Jung Hwan Yoon), Pathology (K.B.L.), and Surgery (K.W.L., N.J.Y., K.S.S.), Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 110-744, Korea; and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul, Korea (J.M.L., J.K.H., B.I.C.)
| | - Jeong Min Lee
- From the Departments of Radiology (W.C., J.M.L., Jeong Hee Yoon, J.K.H., B.I.C.), Internal Medicine (Jung Hwan Yoon), Pathology (K.B.L.), and Surgery (K.W.L., N.J.Y., K.S.S.), Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 110-744, Korea; and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul, Korea (J.M.L., J.K.H., B.I.C.)
| | - Jeong Hee Yoon
- From the Departments of Radiology (W.C., J.M.L., Jeong Hee Yoon, J.K.H., B.I.C.), Internal Medicine (Jung Hwan Yoon), Pathology (K.B.L.), and Surgery (K.W.L., N.J.Y., K.S.S.), Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 110-744, Korea; and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul, Korea (J.M.L., J.K.H., B.I.C.)
| | - Joon Koo Han
- From the Departments of Radiology (W.C., J.M.L., Jeong Hee Yoon, J.K.H., B.I.C.), Internal Medicine (Jung Hwan Yoon), Pathology (K.B.L.), and Surgery (K.W.L., N.J.Y., K.S.S.), Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 110-744, Korea; and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul, Korea (J.M.L., J.K.H., B.I.C.)
| | - Byung Ihn Choi
- From the Departments of Radiology (W.C., J.M.L., Jeong Hee Yoon, J.K.H., B.I.C.), Internal Medicine (Jung Hwan Yoon), Pathology (K.B.L.), and Surgery (K.W.L., N.J.Y., K.S.S.), Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 110-744, Korea; and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul, Korea (J.M.L., J.K.H., B.I.C.)
| | - Jung Hwan Yoon
- From the Departments of Radiology (W.C., J.M.L., Jeong Hee Yoon, J.K.H., B.I.C.), Internal Medicine (Jung Hwan Yoon), Pathology (K.B.L.), and Surgery (K.W.L., N.J.Y., K.S.S.), Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 110-744, Korea; and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul, Korea (J.M.L., J.K.H., B.I.C.)
| | - Kyoung Bun Lee
- From the Departments of Radiology (W.C., J.M.L., Jeong Hee Yoon, J.K.H., B.I.C.), Internal Medicine (Jung Hwan Yoon), Pathology (K.B.L.), and Surgery (K.W.L., N.J.Y., K.S.S.), Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 110-744, Korea; and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul, Korea (J.M.L., J.K.H., B.I.C.)
| | - Kwang-Woong Lee
- From the Departments of Radiology (W.C., J.M.L., Jeong Hee Yoon, J.K.H., B.I.C.), Internal Medicine (Jung Hwan Yoon), Pathology (K.B.L.), and Surgery (K.W.L., N.J.Y., K.S.S.), Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 110-744, Korea; and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul, Korea (J.M.L., J.K.H., B.I.C.)
| | - Nam-Joon Yi
- From the Departments of Radiology (W.C., J.M.L., Jeong Hee Yoon, J.K.H., B.I.C.), Internal Medicine (Jung Hwan Yoon), Pathology (K.B.L.), and Surgery (K.W.L., N.J.Y., K.S.S.), Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 110-744, Korea; and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul, Korea (J.M.L., J.K.H., B.I.C.)
| | - Kyung-Suk Suh
- From the Departments of Radiology (W.C., J.M.L., Jeong Hee Yoon, J.K.H., B.I.C.), Internal Medicine (Jung Hwan Yoon), Pathology (K.B.L.), and Surgery (K.W.L., N.J.Y., K.S.S.), Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 110-744, Korea; and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul, Korea (J.M.L., J.K.H., B.I.C.)
| |
Collapse
|
76
|
Assessment of Liver Stiffness in Pediatric Fontan Patients Using Transient Elastography. Can J Gastroenterol Hepatol 2016; 2016:7125193. [PMID: 27656638 PMCID: PMC5021462 DOI: 10.1155/2016/7125193] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2016] [Accepted: 08/11/2016] [Indexed: 01/09/2023] Open
Abstract
Background. Hepatic fibrosis is a potential complication following Fontan surgery and heralds long-term risk for cirrhosis. Transient elastography (TE) is a rapid, noninvasive method to assess liver fibrosis by measuring liver stiffness. Objectives. To compare liver stiffness and liver biochemistries in pediatric Fontan patients with age- and sex-matched controls and to determine patients' acceptance of TE. Methods. Patients were recruited from British Columbia Children's Hospital. Twenty-two Fontan patients (15 males) were identified. Demographic information and cardiac data were collected. TE was measured using size-appropriate probes. Results. The median age of the Fontan cohort was 13.7 (5.9-16.8) years. Time from Fontan surgery to TE was 9.6 (1.0-12.9) years. The median Fontan circuit pressure was 13 (11-14) mmHg. TE values were higher in Fontan patients versus controls (18.6 versus 4.7 kPa, p < 0.001). There was no association between TE values and patient age (r = 0.41, p = 0.058), time since Fontan surgery (r = 0.40, p = 0.062), or median Fontan circuit pressure (CVP) (r = 0.35, p = 0.111). Patients found TE to be nonpainful, convenient, and safe. Conclusions. TE is feasible to assess liver stiffness in children following Fontan surgery. Pediatric Fontan patients have markedly elevated liver stiffness values. TE may have important utility in liver care follow-up of pediatric Fontan patients.
Collapse
|
77
|
Lupsor-Platon M, Badea R. Noninvasive assessment of alcoholic liver disease using unidimensional transient elastography (Fibroscan ®). World J Gastroenterol 2015; 21:11914-11923. [PMID: 26576080 PMCID: PMC4641113 DOI: 10.3748/wjg.v21.i42.11914] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2015] [Revised: 07/27/2015] [Accepted: 09/14/2015] [Indexed: 02/06/2023] Open
Abstract
Unidimensional transient elastography (TE) is a noninvasive technique, which has been increasingly used in the assessment of diffuse liver diseases. This paper focuses on reviewing the existing data on the use of TE in the diagnosis of fibrosis and in monitoring disease progression in alcoholic liver disease, on the factors that may influence the result of fibrosis prediction, and last but not least, on its potential use in assessing the steatosis degree. Therefore, this field is far from being exhausted and deserves more attention. Further studies are required, on large groups of biopsied patients, in order to find answers to all the remaining questions in this field.
Collapse
|
78
|
Şirli R, Sporea I, Popescu A, Dănilă M. Ultrasound-based elastography for the diagnosis of portal hypertension in cirrhotics. World J Gastroenterol 2015; 21:11542-11551. [PMID: 26556985 PMCID: PMC4631959 DOI: 10.3748/wjg.v21.i41.11542] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2015] [Revised: 07/11/2015] [Accepted: 08/31/2015] [Indexed: 02/06/2023] Open
Abstract
Progressive fibrosis is encountered in almost all chronic liver diseases. Its clinical signs are diagnostic in advanced cirrhosis, but compensated liver cirrhosis is harder to diagnose. Liver biopsy is still considered the reference method for staging the severity of fibrosis, but due to its drawbacks (inter and intra-observer variability, sampling errors, unequal distribution of fibrosis in the liver, and risk of complications and even death), non-invasive methods were developed to assess fibrosis (serologic and elastographic). Elastographic methods can be ultrasound-based or magnetic resonance imaging-based. All ultrasound-based elastographic methods are valuable for the early diagnosis of cirrhosis, especially transient elastography (TE) and acoustic radiation force impulse (ARFI) elastography, which have similar sensitivities and specificities, although ARFI has better feasibility. TE is a promising method for predicting portal hypertension in cirrhotic patients, but it cannot replace upper digestive endoscopy. The diagnostic accuracy of using ARFI in the liver to predict portal hypertension in cirrhotic patients is debatable, with controversial results in published studies. The accuracy of ARFI elastography may be significantly increased if spleen stiffness is assessed, either alone or in combination with liver stiffness and other parameters. Two-dimensional shear-wave elastography, the ElastPQ technique and strain elastography all need to be evaluated as predictors of portal hypertension.
Collapse
|
79
|
Abstract
Noninvasive methods are increasingly used for the assessment of liver fibrosis. Two categories of markers include serum-based markers (biologic properties) or ultrasound and magnetic resonance imaging-based techniques that use the principles of elastography (physical properties) to indirectly assess liver fibrosis. Serum markers can be either direct or indirect markers of the fibrosis process. Common elastography-based studies include vibration-controlled transient elastography, point shear wave elastography, and 2-dimensional shear wave elastography and magnetic resonance elastography. A common theme among all techniques is the inability to accurately differentiate between minimal or moderate stages of fibrosis but superior performance in identifying subjects with cirrhosis or normal liver parenchyma. Noninvasive markers may also serve as prognostic tools to course the natural history of chronic liver disease as well as identify cirrhotic patients at highest risk of future decompensation. Further research is needed to identify the role of noninvasive markers in following asymptomatic individuals, especially in patients with nonalcoholic fatty liver disease.
Collapse
|
80
|
Demir M, Lang S, Steffen HM. Nonalcoholic fatty liver disease - current status and future directions. J Dig Dis 2015; 16:541-57. [PMID: 26406351 DOI: 10.1111/1751-2980.12291] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2015] [Revised: 09/23/2015] [Accepted: 09/23/2015] [Indexed: 12/11/2022]
Abstract
Nonalcoholic fatty liver disease (NAFLD) has emerged as the most common chronic liver disease worldwide with a reported prevalence ranging 6-33%, depending on the studied populations. It encompasses a spectrum of liver manifestations ranging from simple steatosis (also known as nonalcoholic fatty liver, NAFL) to nonalcoholic steatohepatitis (NASH), fibrosis and cirrhosis, which may ultimately progress to hepatocellular carcinoma. NAFLD is strongly associated with the components of metabolic syndrome, mainly obesity and type 2 diabetes mellitus. NAFLD patients are at increased risk of liver-related as well as cardiovascular mortality. Current paradigm suggests a benign course for NAFL whereas NASH is considered to be the progressive phenotype. Although previously under-recognized accumulating evidence suggests that NAFL may also progress, suggesting a higher number of patients at risk than previously appreciated. Liver biopsy remains the gold standard for definitive diagnosis, but the majority of patients can be diagnosed accurately by noninvasive methods. Approved therapies for NAFLD are still lacking and lifestyle modifications aiming at weight loss remain the mainstay of NAFLD treatment. Intensive research could identify insulin resistance, lipotoxicity and dysbiosis of the gut microbiota as major pathophysiological mechanisms, leading to the development of promising targeted therapies which are currently investigated in clinical trials. In this review we summarized the current knowledge of NAFLD epidemiology, natural history, diagnosis, pathogenesis and treatment and considered future directions.
Collapse
Affiliation(s)
- Münevver Demir
- Clinic for Gastroenterology and Hepatology, University Hospital of Cologne, Cologne, Germany
| | - Sonja Lang
- Clinic for Gastroenterology and Hepatology, University Hospital of Cologne, Cologne, Germany
| | - Hans-Michael Steffen
- Clinic for Gastroenterology and Hepatology, University Hospital of Cologne, Cologne, Germany
| |
Collapse
|
81
|
Elastography in Overweight and Obese Patients With Chronic Liver Disease. Clin Gastroenterol Hepatol 2015; 13:1510-2. [PMID: 25912837 DOI: 10.1016/j.cgh.2015.04.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/17/2015] [Revised: 04/16/2015] [Accepted: 04/16/2015] [Indexed: 02/07/2023]
|
82
|
Supersonic Shear Imaging and Transient Elastography With the XL Probe Accurately Detect Fibrosis in Overweight or Obese Patients With Chronic Liver Disease. Clin Gastroenterol Hepatol 2015; 13:1502-9.e5. [PMID: 25804329 DOI: 10.1016/j.cgh.2015.03.014] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND & AIMS Assessment of the severity of liver fibrosis is an important step in evaluating patients with chronic liver disease and determining their prognosis. We compared liver stiffness measurements (LSMs) made by supersonic shear imaging (SSI) with those of transient elastography (TE)-XL for their ability to determine the degree of liver fibrosis in overweight or obese patients with chronic liver disease. METHODS We performed a prospective study of 258 patients with chronic hepatitis of different etiologies and a body mass index greater than 25, evaluated at the University of Miami from October 2013 to December 2014. Liver stiffness was measured using the TE-XL probe and SSI of the right and left lobes during the same clinic visit, and comparisons were made for fibrosis stage in 124 biopsy-proven patients. In addition, further analysis was performed on a subgroup of 102 chronic hepatitis C virus (HCV)-positive patients for whom biopsy data were available. RESULTS Reliable LSMs were obtained from 96.1%, 94.6%, and 72.1% of patients using the TE-XL probe, SSI of the right lobe, and SSI of the left lobe, respectively. TE-XL, SSI of the right lobe, and SSI of the left lobe detected severe fibrosis (fibrosis stages 3-4), with area under the receiver operating characteristic curve (AUROC) values of 0.955, 0.954, and 0.910, respectively, compared with results from histologic analysis for the 124 biopsy-proven patients included in the study; these values were 0.952, 0.949, and 0.917, respectively, for the 102 biopsy-proven patients with HCV infection. TE-XL, SSI of the right lobe, and SSI of the left lobe detected fibrosis stage 4 with AUROC values of 0.920, 0.930, and 0.910, respectively, compared with histologic analysis, in all 124-biopsy proven patients, and with AUROC values of 0.907, 0.914, and 0.887, respectively, in the 102 biopsy-proven patients with chronic HCV infection. CONCLUSIONS SSI and the TE-XL probe each accurately quantify liver fibrosis in overweight or obese patients with chronic liver disease, including those with HCV infection, when compared with data obtained from histologic analysis. SSI data obtained from the right lobe and the TE-XL probe can be used to evaluate fibrosis with similar accuracy.
Collapse
|
83
|
Understanding the Complexities of Cirrhosis. Clin Ther 2015; 37:1822-36. [DOI: 10.1016/j.clinthera.2015.05.507] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2015] [Revised: 03/25/2015] [Accepted: 05/08/2015] [Indexed: 12/13/2022]
|
84
|
Van Gossum A, Pironi L, Messing B, Moreno C, Colecchia A, D'Errico A, Demetter P, De Gos F, Cazals-Halem D, Joly F. Transient Elastography (FibroScan) Is Not Correlated With Liver Fibrosis but With Cholestasis in Patients With Long-Term Home Parenteral Nutrition. JPEN J Parenter Enteral Nutr 2015; 39:719-724. [PMID: 24913657 DOI: 10.1177/0148607114538057] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2013] [Accepted: 04/29/2014] [Indexed: 01/05/2025]
Abstract
BACKGROUND Long-term home parenteral nutrition (HPN) may induce liver disorders. Transient elastography (TE) has been proposed as a noninvasive alternative to liver biopsy analysis for assessment of the progression of hepatic fibrosis to cirrhosis. The goal of this study was to compare values from TE measurements to biopsy-determined stages of histologic fibrosis in patients receiving HPN. METHODS In this multicenter prospective study, patients receiving long-term HPN (≥ 6 months) who required a liver biopsy for clinical reasons were included. TE (FibroScan) values for each patient were compared with the degree of hepatic fibrosis measured from biopsy specimens based on the Brunt classification. TE values were also correlated to biochemical and histologic cholestasis. Two noninvasive indices for predicting liver fibrosis (APRI and FIB-4) were also evaluated. RESULTS Thirty patients were included in this study (mean age, 42.1 years; 63% male). The mean duration of HPN was 100.7 months; 25 patients had a short bowel and 13 had an intestinal stoma. Biochemical cholestasis was described in 22 patients. Liver histologic features varied among these patients. There was no correlation between the values of TE and the stages of histologic fibrosis, but TE values were significantly correlated to serum bilirubin level and the severity of histologic cholestasis as well as APRI and FIB-4 scores. CONCLUSIONS In patients with long-term HPN, TE failed to assess the degree of hepatic fibrosis. This could be due to the heterogeneity of liver histologic features observed in these patients and the presence of chronic cholestasis.
Collapse
Affiliation(s)
- André Van Gossum
- Department of Gastroenterology and Pathology, Hôpital Erasme, Brussels, Belgium
| | - Loris Pironi
- Department of Gastroenterology and Pathology, St Orsola-Malpighi Hospital, Bologna, Italy
| | - Bernard Messing
- Department of Gastroenterology and Pathology, Hôpital Beaujon, Paris, France
| | - Christophe Moreno
- Department of Gastroenterology and Pathology, Hôpital Erasme, Brussels, Belgium
| | - Antonio Colecchia
- Department of Gastroenterology and Pathology, St Orsola-Malpighi Hospital, Bologna, Italy
| | - Antonietta D'Errico
- Department of Gastroenterology and Pathology, St Orsola-Malpighi Hospital, Bologna, Italy
| | - Pieter Demetter
- Department of Gastroenterology and Pathology, Hôpital Erasme, Brussels, Belgium
| | - Françoise De Gos
- Department of Gastroenterology and Pathology, Hôpital Beaujon, Paris, France
| | | | - Francisca Joly
- Department of Gastroenterology and Pathology, Hôpital Beaujon, Paris, France
| |
Collapse
|
85
|
EASL-ALEH Clinical Practice Guidelines: Non-invasive tests for evaluation of liver disease severity and prognosis. J Hepatol 2015; 63:237-64. [PMID: 25911335 DOI: 10.1016/j.jhep.2015.04.006] [Citation(s) in RCA: 1317] [Impact Index Per Article: 131.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2015] [Accepted: 04/09/2015] [Indexed: 02/06/2023]
|
86
|
Abstract
INTRODUCTION Elastometry is more accurate than blood tests for cirrhosis diagnosis. However, blood tests were developed for significant fibrosis, with the exception of CirrhoMeter developed for cirrhosis. We compared the performance of Fibroscan and CirrhoMeter, and classic binary cirrhosis diagnosis versus new fibrosis staging for cirrhosis diagnosis. METHODS The diagnostic population included 679 patients with hepatitis C and liver biopsy (Metavir staging and morphometry), Fibroscan, and CirrhoMeter. The prognostic population included 1110 patients with chronic liver disease and both tests. RESULTS Binary diagnosis: AUROCs for cirrhosis were: Fibroscan: 0.905; CirrhoMeter: 0.857; and P=0.041. Accuracy (Youden cutoff) was: Fibroscan: 85.4%; CirrhoMeter: 79.2%; and P<0.001. Fibrosis classification provided 6 classes (F0/1, F1/2, F2±1, F3±1, F3/4, and F4). Accuracy was: Fibroscan: 88.2%; CirrhoMeter: 88.8%; and P=0.77. A simplified fibrosis classification comprised 3 categories: discrete (F1±1), moderate (F2±1), and severe (F3/4) fibrosis. Using this simplified classification, CirrhoMeter predicted survival better than Fibroscan (respectively, χ=37.9 and 19.7 by log-rank test), but both predicted it well (P<0.001 by log-rank test). Comparison: binary diagnosis versus fibrosis classification, respectively, overall accuracy: CirrhoMeter: 79.2% versus 88.8% (P<0.001); Fibroscan: 85.4% versus 88.2% (P=0.127); positive predictive value for cirrhosis by Fibroscan: Youden cutoff (11.1 kPa): 49.1% versus cutoffs of F3/4 (17.6 kPa): 67.6% and F4 classes (25.7 kPa): 82.4%. CONCLUSIONS Fibroscan's usual binary cutoffs for cirrhosis diagnosis are not sufficiently accurate. Fibrosis classification should be preferred over binary diagnosis. A cirrhosis-specific blood test markedly attenuates the accuracy deficit for cirrhosis diagnosis of usual blood tests versus transient elastometry, and may offer better prognostication.
Collapse
|
87
|
Casado JL, Mena A, Bañón S, Castro A, Quereda C, Moreno A, Pedreira J, Moreno S. Liver toxicity and risk of discontinuation in HIV/hepatitis C virus-coinfected patients receiving an etravirine-containing antiretroviral regimen: influence of liver fibrosis. HIV Med 2015; 17:62-7. [PMID: 26122981 DOI: 10.1111/hiv.12274] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/19/2015] [Indexed: 11/27/2022]
Abstract
OBJECTIVES The aim of the study was to establish the risk of liver toxicity in HIV/hepatitis C virus (HCV)-coinfected patients receiving etravirine, according to the degree of liver fibrosis. METHODS A prospective cohort study of 211 HIV-infected patients initiating an etravirine-containing regimen was carried out. HCV coinfection was defined as a positive HCV RNA test, and baseline liver fibrosis was assessed by transient elastography. Hepatotoxicity was defined as clinical symptoms, or an aspartate aminotransferase (AST) or alanine aminotransferase (ALT) value > 5-fold higher than the upper limit of normal if baseline values were normal, or 3.5-fold higher if values were altered at baseline. RESULTS Overall, 145 patients (69%) were HCV coinfected, with a lower nadir (165 versus 220 cells/μL, respectively; p = 0.03) and baseline (374 versus 498 cells/μL, respectively; p = 0.04) CD4 count than monoinfected patients. Etravirine was mainly used with two nucleoside reverse transcriptase inhibitors (129; 61%) or with a boosted protease inhibitor (PI) (28%), with no significant differences according to HCV serostatus. Transient elastography in 117 patients (81%) showed a median (range) stiffness value of 8.25 (3.5-69) kPa, with fibrosis stage 1 in 43 patients (37%) and fibrosis stage 4 in 28 patients (24%). During an accumulated follow-up time of 449.3 patient-years (median 548 days), only one patient with advanced fibrosis (50.8 kPa) had grade 3-4 liver toxicity (0.7%). Transaminases changed slightly, with no significant differences compared with baseline fibrosis, and nine and six patients had grade 1 and 2 transaminase increases, respectively. Also, HCV coinfection was not associated with a higher risk of discontinuation (25% discontinued versus 21% of monoinfected patients; p = 0.39, log-rank test) or virological failure (8% versus 12%, respectively; p = 0.4). CONCLUSIONS Our data suggest that etravirine is a safe option for HIV/HCV-coinfected patients, including those with significant liver fibrosis.
Collapse
Affiliation(s)
- J L Casado
- Department of Infectious Diseases, Ramon y Cajal Hospital, Madrid, Spain
| | - A Mena
- Department of Internal Medicine, INIBIC-Complexo Universitario Hospitalario, A Coruña, Spain
| | - S Bañón
- Department of Infectious Diseases, Ramon y Cajal Hospital, Madrid, Spain
| | - A Castro
- Department of Internal Medicine, INIBIC-Complexo Universitario Hospitalario, A Coruña, Spain
| | - C Quereda
- Department of Infectious Diseases, Ramon y Cajal Hospital, Madrid, Spain
| | - A Moreno
- Department of Infectious Diseases, Ramon y Cajal Hospital, Madrid, Spain
| | - J Pedreira
- Department of Internal Medicine, INIBIC-Complexo Universitario Hospitalario, A Coruña, Spain
| | - S Moreno
- Department of Infectious Diseases, Ramon y Cajal Hospital, Madrid, Spain
| |
Collapse
|
88
|
Huhdanpaa HT, Zhang P, Krishnamurthy VN, Douville C, Enchakolody B, Chou C, Ethiraj S, Wang S, Su GL. Quantitative detection of cirrhosis: towards the development of computer-assisted detection method. J Digit Imaging 2015; 27:601-9. [PMID: 24811859 DOI: 10.1007/s10278-014-9696-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
There are distinct morphologic features of cirrhosis on CT examinations; however, such impressions may be subtle or subjective. The purpose of this study is to build a computer-aided diagnosis (CAD) method to help radiologists with this diagnosis. One hundred sixty-seven abdominal CT examinations were randomly divided into training (n = 88) and validation (n = 79) sets. Livers were analyzed for morphological markers of cirrhosis and logistic regression models were created. Using the area under curve (AUC) for model performance, the best model had 0.89 for the training set and 0.85 for the validation set. For radiology reports, sensitivity of reporting cirrhosis was 0.45 and specificity 0.99. Using the predictive model adjunctively, radiologists' sensitivity increased to 0.63 and specificity slightly decreased to 0.97. This study demonstrates that quantifying morphological features in livers may be utilized for diagnosing cirrhosis and for developing a CAD method for it.
Collapse
Affiliation(s)
- Hannu T Huhdanpaa
- Department of Radiology, University of Southern California, 1500 San Pablo Street, Second Floor Imaging, Los Angeles, CA, 90033, USA,
| | | | | | | | | | | | | | | | | |
Collapse
|
89
|
Tai DI, Tsay PK, Jeng WJ, Weng CC, Huang SF, Huang CH, Lin SM, Chiu CT, Chen WT, Wan YL. Differences in liver fibrosis between patients with chronic hepatitis B and C: evaluation by acoustic radiation force impulse measurements at 2 locations. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2015; 34:813-821. [PMID: 25911714 DOI: 10.7863/ultra.34.5.813] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2014] [Accepted: 08/12/2014] [Indexed: 02/05/2023]
Abstract
OBJECTIVES The purpose of this study was to evaluate liver fibrosis by acoustic radiation force impulse (ARFI) measurements at 2 locations in patients with chronic hepatitis B and C. METHODS A total of 204 consecutive patients (146 male and 58 female) with chronic hepatitis B (n = 121) and C (n = 83) who underwent liver biopsy were enrolled. All patients received ARFI measurements at 2 locations in the right intercostal space on the same day as biopsy. RESULTS There was no difference in median ARFI values between detection locations. However, a significant difference was found for low and high values between locations (median ± SD, 1.38 ± 0.43 versus 1.56 ± 0.55 m/s; P < .001). By receiver operating characteristic (ROC) curve analysis for a METAVIR fibrosis score of F4 (cirrhosis), the lower value of 2 measurements had the highest area under the ROC curve (0.750), followed by the mean value (0.744) and the higher value (0.730). Patients with hepatitis C had a higher area under the ROC curve than patients with hepatitis B (0.824 versus 0.707) for predicting liver cirrhosis. By logistic regression analysis, ARFI was the best modality for predicting liver cirrhosis in hepatitis C, and conventional sonography was the best modality in hepatitis B (P < .001). The ARFI value in patients with hepatitis B was significantly influenced by liver inflammation (P = .019). CONCLUSIONS Acoustic radiation force impulse imaging is the modality of choice for predicting liver cirrhosis in chronic hepatitis C, whereas conventional sonography is still the modality of choice in chronic hepatitis B.
Collapse
Affiliation(s)
- Dar-In Tai
- Departments of Gastroenterology and Hepatology (D.-I.T., W.-J.J., C.-C.W., C.-H.H., S.-M.L., C.-T.C., W.-T.C.) and Medical Imaging and Intervention (Y.-L.W.), Chang Gung Memorial Hospital, Taipei, Taiwan; Department of Public Health and Center of Biostatistics, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (P.-K.T.); Division of Molecular and Genomic Medicine, National Health Research Institute, Taipei, Taiwan (S.-F.H.); and Department of Medical Imaging and Radiological Sciences, College of Medicine, Institute for Radiological Research, Chang Gung University, Tao-Yuan, Taiwan (Y.-L.W.)
| | - Pei-Kwei Tsay
- Departments of Gastroenterology and Hepatology (D.-I.T., W.-J.J., C.-C.W., C.-H.H., S.-M.L., C.-T.C., W.-T.C.) and Medical Imaging and Intervention (Y.-L.W.), Chang Gung Memorial Hospital, Taipei, Taiwan; Department of Public Health and Center of Biostatistics, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (P.-K.T.); Division of Molecular and Genomic Medicine, National Health Research Institute, Taipei, Taiwan (S.-F.H.); and Department of Medical Imaging and Radiological Sciences, College of Medicine, Institute for Radiological Research, Chang Gung University, Tao-Yuan, Taiwan (Y.-L.W.)
| | - Wen-Juei Jeng
- Departments of Gastroenterology and Hepatology (D.-I.T., W.-J.J., C.-C.W., C.-H.H., S.-M.L., C.-T.C., W.-T.C.) and Medical Imaging and Intervention (Y.-L.W.), Chang Gung Memorial Hospital, Taipei, Taiwan; Department of Public Health and Center of Biostatistics, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (P.-K.T.); Division of Molecular and Genomic Medicine, National Health Research Institute, Taipei, Taiwan (S.-F.H.); and Department of Medical Imaging and Radiological Sciences, College of Medicine, Institute for Radiological Research, Chang Gung University, Tao-Yuan, Taiwan (Y.-L.W.)
| | - Chia-Chan Weng
- Departments of Gastroenterology and Hepatology (D.-I.T., W.-J.J., C.-C.W., C.-H.H., S.-M.L., C.-T.C., W.-T.C.) and Medical Imaging and Intervention (Y.-L.W.), Chang Gung Memorial Hospital, Taipei, Taiwan; Department of Public Health and Center of Biostatistics, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (P.-K.T.); Division of Molecular and Genomic Medicine, National Health Research Institute, Taipei, Taiwan (S.-F.H.); and Department of Medical Imaging and Radiological Sciences, College of Medicine, Institute for Radiological Research, Chang Gung University, Tao-Yuan, Taiwan (Y.-L.W.)
| | - Shiu-Feng Huang
- Departments of Gastroenterology and Hepatology (D.-I.T., W.-J.J., C.-C.W., C.-H.H., S.-M.L., C.-T.C., W.-T.C.) and Medical Imaging and Intervention (Y.-L.W.), Chang Gung Memorial Hospital, Taipei, Taiwan; Department of Public Health and Center of Biostatistics, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (P.-K.T.); Division of Molecular and Genomic Medicine, National Health Research Institute, Taipei, Taiwan (S.-F.H.); and Department of Medical Imaging and Radiological Sciences, College of Medicine, Institute for Radiological Research, Chang Gung University, Tao-Yuan, Taiwan (Y.-L.W.)
| | - Chien-Hao Huang
- Departments of Gastroenterology and Hepatology (D.-I.T., W.-J.J., C.-C.W., C.-H.H., S.-M.L., C.-T.C., W.-T.C.) and Medical Imaging and Intervention (Y.-L.W.), Chang Gung Memorial Hospital, Taipei, Taiwan; Department of Public Health and Center of Biostatistics, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (P.-K.T.); Division of Molecular and Genomic Medicine, National Health Research Institute, Taipei, Taiwan (S.-F.H.); and Department of Medical Imaging and Radiological Sciences, College of Medicine, Institute for Radiological Research, Chang Gung University, Tao-Yuan, Taiwan (Y.-L.W.)
| | - Shi-Ming Lin
- Departments of Gastroenterology and Hepatology (D.-I.T., W.-J.J., C.-C.W., C.-H.H., S.-M.L., C.-T.C., W.-T.C.) and Medical Imaging and Intervention (Y.-L.W.), Chang Gung Memorial Hospital, Taipei, Taiwan; Department of Public Health and Center of Biostatistics, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (P.-K.T.); Division of Molecular and Genomic Medicine, National Health Research Institute, Taipei, Taiwan (S.-F.H.); and Department of Medical Imaging and Radiological Sciences, College of Medicine, Institute for Radiological Research, Chang Gung University, Tao-Yuan, Taiwan (Y.-L.W.)
| | - Cheng-Tang Chiu
- Departments of Gastroenterology and Hepatology (D.-I.T., W.-J.J., C.-C.W., C.-H.H., S.-M.L., C.-T.C., W.-T.C.) and Medical Imaging and Intervention (Y.-L.W.), Chang Gung Memorial Hospital, Taipei, Taiwan; Department of Public Health and Center of Biostatistics, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (P.-K.T.); Division of Molecular and Genomic Medicine, National Health Research Institute, Taipei, Taiwan (S.-F.H.); and Department of Medical Imaging and Radiological Sciences, College of Medicine, Institute for Radiological Research, Chang Gung University, Tao-Yuan, Taiwan (Y.-L.W.)
| | - Wei-Ting Chen
- Departments of Gastroenterology and Hepatology (D.-I.T., W.-J.J., C.-C.W., C.-H.H., S.-M.L., C.-T.C., W.-T.C.) and Medical Imaging and Intervention (Y.-L.W.), Chang Gung Memorial Hospital, Taipei, Taiwan; Department of Public Health and Center of Biostatistics, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (P.-K.T.); Division of Molecular and Genomic Medicine, National Health Research Institute, Taipei, Taiwan (S.-F.H.); and Department of Medical Imaging and Radiological Sciences, College of Medicine, Institute for Radiological Research, Chang Gung University, Tao-Yuan, Taiwan (Y.-L.W.)
| | - Yung-Liang Wan
- Departments of Gastroenterology and Hepatology (D.-I.T., W.-J.J., C.-C.W., C.-H.H., S.-M.L., C.-T.C., W.-T.C.) and Medical Imaging and Intervention (Y.-L.W.), Chang Gung Memorial Hospital, Taipei, Taiwan; Department of Public Health and Center of Biostatistics, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (P.-K.T.); Division of Molecular and Genomic Medicine, National Health Research Institute, Taipei, Taiwan (S.-F.H.); and Department of Medical Imaging and Radiological Sciences, College of Medicine, Institute for Radiological Research, Chang Gung University, Tao-Yuan, Taiwan (Y.-L.W.)
| |
Collapse
|
90
|
Ultrasound Elastography and MR Elastography for Assessing Liver Fibrosis: Part 2, Diagnostic Performance, Confounders, and Future Directions. AJR Am J Roentgenol 2015; 205:33-40. [PMID: 25905762 DOI: 10.2214/ajr.15.14553] [Citation(s) in RCA: 147] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
OBJECTIVE The purpose of the article is to review the diagnostic performance of ultra-sound and MR elastography techniques for detection and staging of liver fibrosis, the main current clinical applications of elastography in the abdomen. CONCLUSION Technical and instrument-related factors and biologic and patient-related factors may constitute potential confounders of stiffness measurements for assessment of liver fibrosis. Future developments may expand the scope of elastography for monitoring liver fibrosis and predict complications of chronic liver disease.
Collapse
|
91
|
Zheng J, Guo H, Zeng J, Huang Z, Zheng B, Ren J, Xu E, Li K, Zheng R. Two-dimensional shear-wave elastography and conventional US: the optimal evaluation of liver fibrosis and cirrhosis. Radiology 2015; 275:290-300. [PMID: 25575116 DOI: 10.1148/radiol.14140828] [Citation(s) in RCA: 96] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
PURPOSE To evaluate the individual and combined performances of two-dimensional (2D) shear-wave elastography (SWE) and conventional ultrasonography (US) in assessing liver fibrosis and cirrhosis to determine when 2D SWE should be added to routine US. MATERIALS AND METHODS This prospective study was approved by the institutional ethics committee, and the patients provided written informed consent. Between April 2012 and March 2013, conventional US and 2D SWE examinations were performed in 198 patients (mean age, 37.7 years; age range, 18-67 years) with chronic liver disease. Liver biopsy was used as a reference standard for 167 patients; the other 31 patients had decompensated liver cirrhosis. Receiver operating characteristic (ROC) curves were obtained to assess the diagnostic performance. Differences between the areas under the ROC curves (AUCs) were compared by using a Delong test. RESULTS Two-dimensional SWE was significantly superior to US in diagnosis of significant fibrosis (score of F2 or greater) (AUC, 0.862 vs 0.725; P = .001) and early cirrhosis (score of F4) (AUC, 0.926 vs 0.789; P = .007). Combining 2D SWE with US did not increase the performance of depicting either significant fibrosis or liver cirrhosis (P = .713 and 0.410, respectively) relative to 2D SWE alone. There was no significant difference between 2D SWE and US in diagnosis of decompensated cirrhosis (AUC, 0.878 vs 0.925; P = .323). In addition, combining 2D SWE with US did not increase the performance relative to that of US alone (P = .372). CONCLUSION Conventional US is sufficient to detect decompensated cirrhosis. Two-dimensional SWE is significantly superior to US in detecting liver fibrosis. Combining 2D SWE and US did not improve the diagnostic performance for either fibrosis or cirrhosis.
Collapse
Affiliation(s)
- Jian Zheng
- From the Department of Medical Ultrasonics, Third Affiliated Hospital of Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, China
| | | | | | | | | | | | | | | | | |
Collapse
|
92
|
Pavlov CS, Casazza G, Nikolova D, Tsochatzis E, Burroughs AK, Ivashkin VT, Gluud C. Transient elastography for diagnosis of stages of hepatic fibrosis and cirrhosis in people with alcoholic liver disease. Cochrane Database Syst Rev 2015; 1:CD010542. [PMID: 25612182 PMCID: PMC7081746 DOI: 10.1002/14651858.cd010542.pub2] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND The presence and progression of hepatic (liver) fibrosis into cirrhosis is a prognostic variable having impact on survival in people with alcoholic liver disease. Liver biopsy, although an invasive method, is the recommended 'reference standard' for diagnosis and staging of hepatic fibrosis in people with liver diseases. Transient elastography is a non-invasive method for assessing and staging hepatic fibrosis. OBJECTIVES To determine the diagnostic accuracy of transient elastography for diagnosis and staging hepatic fibrosis in people with alcoholic liver disease when compared with liver biopsy. To identify the optimal cut-off values for differentiating the five stages of hepatic fibrosis. SEARCH METHODS The Cochrane Hepato-Biliary Group Controlled and Diagnostic Test Accuracy Studies Registers, The Cochrane Library, MEDLINE (OvidSP), EMBASE (OvidSP), and the Science Citation Index Expanded (last search August 2014). SELECTION CRITERIA Diagnostic cohort and diagnostic case-control study designs that assessed hepatic fibrosis in participants with alcoholic liver disease with transient elastography and liver biopsy, irrespective of language or publication status. The study participants could be of any sex and ethnic origin, above 16 years old, hospitalised or managed as outpatients. We excluded participants with viral hepatitis, autoimmunity, metabolic diseases, and toxins. DATA COLLECTION AND ANALYSIS We followed the guidelines in the draft Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy. MAIN RESULTS Five retrospective and nine prospective cohort studies with 834 participants provided data for the review analyses. Authors of seven of those studies sent us individual participant data. The risk of bias in the included studies was high in all but three studies. We could identify no serious concerns regarding the applicability of the studies in answering the main study question of our review, namely to use transient elastography to diagnose hepatic fibrosis. We could not identify the optimal cut-off values for the fibrosis stages. The definition of the diagnosis of alcoholic liver disease was not provided in one study and was not clearly defined in two studies, but it was clear in the remaining 11 studies. The study authors used different liver stiffness cut-off values of transient elastography for the hepatic fibrosis stages.There was only one study (103 participants) with data on hepatic fibrosis stage F1 or worse, with a cut-off of 5.9 kPa, and reporting sensitivity of 0.83 (95% confidence interval (CI) 0.74 to 0.90) and specificity of 0.88 (95% CI 0.47 to 1.00). The summary sensitivity and specificity of transient elastography for F2 or worse (seven studies with 338 participants and with cut-offs around 7.5 kPa (range 7.00 to 7.8 kPa)) were 0.94 and 0.89 with LR+ 8.2 and LR- 0.07, which suggests that transient elastography could be useful to rule out the presence of significant hepatic fibrosis, thus avoiding liver biopsy.Due to the wide range of cut-off values (from 8.0 to 17.0 kPa) found in the 10 studies with 760 participants with hepatic fibrosis F3 or worse, we fitted a hierarchical summary receiver operating characteristic (HSROC) model and estimated a summary ROC (SROC) curve. The sensitivity of the 10 studies varied from 72% to 100% and the specificity from 59% to 89%. We performed an additional analysis by including the studies with a cut-off value of around and equal to 9.5 kPa (range 8.0 to 11.0 kPa). The summary sensitivity and specificity of transient elastography (eight studies with 564 participants) were 0.92 and 0.70 with LR+ 3.1 and LR- 0.11, which suggests that transient elastography could also be useful to rule out the presence of severe hepatic fibrosis (F3 or worse), avoiding liver biopsy. We carried out a sensitivity analysis by considering only the studies with a cut-off value equal to 9.5 kPa and the result did not differ.We performed an HSROC analysis and reported an SROC curve for hepatic fibrosis stage F4 (cirrhosis). The HSROC analysis suggested that when the cut-off value changes, there is a wide variation in specificity and a more limited variation in sensitivity. We performed an additional analysis with the studies with the most commonly used cut-off value of 12.5 kPa. The summary sensitivity and specificity of transient elastography (seven studies with 330 participants) were 0.95 and 0.71 with LR+ 3.3 and LR- 0.07, which again suggests that transient elastography could be useful to rule out the presence of cirrhosis, avoiding liver biopsy. AUTHORS' CONCLUSIONS We identified a small number of studies with a few participants and were unable to include several studies, which raises the risk of outcome reporting bias. With these caveats in mind, transient elastography may be used as a diagnostic method to rule out liver cirrhosis (F4) in people with alcoholic liver disease when the pre-test probability is about 51% (range 15% to 79%). Transient elastography may also help in ruling out severe fibrosis (F3 or worse). Liver biopsy investigation remains an option if the certainty to rule in or rule out the stage of hepatic fibrosis or cirrhosis remains insufficient after a clinical follow-up or any other non-invasive test considered useful by the clinician.The proposed cut-off values for the different stages of hepatic fibrosis may be used in clinical practice, but caution is needed, as those values reported in this review are only the most common cut-off values used by the study authors. The best cut-off values for hepatic fibrosis in people with alcoholic liver disease could not be established yet.In order to diagnose correctly the stage of hepatic fibrosis in people with alcoholic liver disease using transient elastography assessment, the studies should consider a single aetiology. Hepatic fibrosis should be diagnosed with both transient elastography and liver biopsy and in this sequence, and transient elastography cut-off values should be pre-specified and validated. The time interval between the two investigations should not exceed three months, which is the interval mainly valid for people without cirrhosis, and assessment of results should be properly blinded. Only studies with low risk of bias, fulfilling the Standards for Reporting of Diagnostic Accuracy may answer the review question.
Collapse
Affiliation(s)
- Chavdar S Pavlov
- Copenhagen Trial Unit, Centre for Clinical Intervention Research, Department 7812, Rigshospitalet, Copenhagen University HospitalThe Cochrane Hepato‐Biliary GroupBlegdamsvej 9CopenhagenDenmarkDK‐2100
- I.M. Sechenov First Moscow State Medical UniversityClinic of Internal Diseases PropedeuticsPogodinskaja 1MoscowRussian Federation119991
| | - Giovanni Casazza
- Copenhagen Trial Unit, Centre for Clinical Intervention Research, Department 7812, Rigshospitalet, Copenhagen University HospitalThe Cochrane Hepato‐Biliary GroupBlegdamsvej 9CopenhagenDenmarkDK‐2100
- Università degli Studi di MilanoDipartimento di Scienze Biomediche e Cliniche "L. Sacco"via GB Grassi 74MilanItaly20157
| | - Dimitrinka Nikolova
- Copenhagen Trial Unit, Centre for Clinical Intervention Research, Department 7812, Rigshospitalet, Copenhagen University HospitalThe Cochrane Hepato‐Biliary GroupBlegdamsvej 9CopenhagenDenmarkDK‐2100
| | - Emmanuel Tsochatzis
- Royal Free Hampstead NHS Foundation Trust and UCL Institute of Liver and Digestive HealthSheila Sherlock Liver CentrePond StreetHampsteadLondonUKNW3 2QG
| | - Andrew K Burroughs
- Royal Free Hampstead NHS Foundation TrustSheila Sherlock Liver CentrePond StreetHampsteadLondonUKNW3 2QG
| | - Vladimir T Ivashkin
- I.M. Sechenov First Moscow State Medical UniversityClinic of Internal Diseases PropedeuticsPogodinskaja 1MoscowRussian Federation119991
| | - Christian Gluud
- Copenhagen Trial Unit, Centre for Clinical Intervention Research, Department 7812, Rigshospitalet, Copenhagen University HospitalThe Cochrane Hepato‐Biliary GroupBlegdamsvej 9CopenhagenDenmarkDK‐2100
| | | |
Collapse
|
93
|
A health technology assessment of transient elastography in adult liver disease. CANADIAN JOURNAL OF GASTROENTEROLOGY = JOURNAL CANADIEN DE GASTROENTEROLOGIE 2015; 27:149-58. [PMID: 23516679 DOI: 10.1155/2013/684982] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND An estimated one in 10 Canadians have some form of liver disease. The reference standard for staging and monitoring liver fibrosis is percutaneous liver biopsy--an invasive procedure associated with risks and complications. Transient elastography (TE) represents a noninvasive, ultrasound-based alternative. OBJECTIVE To assess the efficacy of TE compared with liver biopsy for fibrosis staging in adults with five common types of liver disease: hepatitis B, hepatitis C, nonalcoholic fatty liver disease, cholestatic liver disease and complications post-liver transplantation. METHODS A systematic review of published and grey literature from 2001 to June 2011 was conducted. Included were observational studies evaluating the accuracy of TE using liver biopsy as the comparator. An economic model was developed to estimate the cost per correct diagnosis gained with liver biopsy compared with TE. Identification of moderate fibrosis (stages 2 to 4) and cirrhosis (stage 4) were considered. RESULTS Fifty-seven studies were included in the review. The diagnostic accuracy of TE for the five clinical subgroups had sensitivities ranging from 0.67 to 0.92 and specificities ranging from 0.72 to 0.95. Liver biopsy was associated with an additional $1,427 to $7,030 per correct diagnosis gained compared with TE. The model was sensitive to the sensitivity and specificity of TE and the prevalence of fibrosis. CONCLUSIONS TE is an accurate diagnostic method in patients with moderate fibrosis or cirrhosis. TE is less effective but less expensive than liver biopsy. Systemic implementation of TE should be considered for the noninvasive assessment of liver fibrosis.
Collapse
|
94
|
Yoon JH, Lee JM, Joo I, Lee ES, Sohn JY, Jang SK, Lee KB, Han JK, Choi BI. Hepatic fibrosis: prospective comparison of MR elastography and US shear-wave elastography for evaluation. Radiology 2014; 273:772-782. [PMID: 25007047 DOI: 10.1148/radiol.14132000] [Citation(s) in RCA: 135] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
Abstract
PURPOSE To compare magnetic resonance (MR) elastography and ultrasonographic shear-wave elastography ( SWE shear-wave elastography ) for the staging of hepatic fibrosis ( HF hepatic fibrosis ) in the same individuals. MATERIALS AND METHODS This prospective study was approved by the institutional review board, and informed consent was obtained from all patients. The technical success of and reliable liver stiffness ( LS liver stiffness ) measurement rates at MR elastography and SWE shear-wave elastography were compared in 129 patients who underwent both examinations. For mutual validation, LS liver stiffness values measured at both examinations were correlated by using Pearson correlation. The diagnostic performance of the two techniques for the assessment of substantial HF hepatic fibrosis (stage ≥ F2) was compared by using nonparametric receiver operating characteristic analysis. RESULTS The technical success rates of MR elastography and SWE shear-wave elastography were 95.35% (123 of 129) and 97.67% (126 of 129), respectively (P = .51). MR elastography provided significantly more reliable LS liver stiffness measurements than did SWE shear-wave elastography (95.35% [123 of 129] vs 75.2% [97 of 129], P < .001). The two examinations showed moderate correlation (r = 0.724). In patients with HF hepatic fibrosis stages of F3 or lower, the two examinations showed moderate-to-strong correlation (r = 0.683 in normal livers, 0.754 in livers with stage F0 or F1 HF hepatic fibrosis , and 0.90 in livers with stage F2 or F3 HF hepatic fibrosis ; P < .001); however, they did not show significant correlation for stage F4 HF hepatic fibrosis (r = 0.30, P = .31). MR elastography and SWE shear-wave elastography showed similar diagnostic capability in depicting HF hepatic fibrosis of stage F2 or greater (P = .98) when LS liver stiffness measurements were reliably performed. CONCLUSION MR elastography and SWE shear-wave elastography showed moderate correlation and similar diagnostic performance in the diagnosis of HF hepatic fibrosis of stage F2 or greater; however, MR elastography yielded more reliable LS liver stiffness measurements than did SWE shear-wave elastography .
Collapse
Affiliation(s)
- Jeong Hee Yoon
- From the Departments of Radiology (J.H.Y., J.M.L., I.J., E.S.L., J.Y.S., S.K.J., J.K.H., B.I.C.) and Pathology (K.B.L.), Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 110-744, Korea; and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul, Korea (J.M.L., J.K.H., B.I.C.)
| | | | | | | | | | | | | | | | | |
Collapse
|
95
|
Harkisoen S, Boland GJ, van den Hoek JAR, van Erpecum KJ, Hoepelman AIM, Arends JE. ELF-test less accurately identifies liver cirrhosis diagnosed by liver stiffness measurement in non-Asian women with chronic hepatitis B. J Clin Virol 2014; 61:503-8. [PMID: 25467860 DOI: 10.1016/j.jcv.2014.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2014] [Revised: 10/15/2014] [Accepted: 10/18/2014] [Indexed: 10/24/2022]
Abstract
BACKGROUND The enhanced liver fibrosis test (ELF-test) has been validated for several hepatic diseases. However, its performance in chronic hepatitis B virus (CHB) infected patients is uncertain. OBJECTIVE This study investigates the diagnostic value of the ELF test for cirrhosis identified by liver stiffness measurement (LSM) in non-Asian women with CHB. STUDY DESIGN Women of non-Asian origin with perinatally acquired CHB infection, detected during pregnancy in the period 1990-2003, returned to our center between September 2011 and May 2012 for LSM and blood sampling to perform an ELF test and to calculate, APRI and FIB-4 scores. Fibrosis stages were classified by the METAVIR system. RESULTS A total of 119 women were included in this study with a median age of 43 years, all ALT levels being <2× ULN and all being HBeAg negative. The overall median LSM (IQR) stiffness and ELF test were 5.5kPa (4.0-6.8) and 8.4 (7.8-9.2) respectively. LSM and ELF test classified 14 (12%) and 19 (16%) patients with severe fibrosis to cirrhosis (≥F3, i.e. liver stiffness >8.1kPa), however in only 4 (3%) patients there was an agreement between LSM and ELF test. With LSM as reference, the area under receiver operating characteristic curve (AUROC) for detection of ≥F3 fibrosis was for ELF 0.65 (95% CI 0.51-0.80; p=0.06), APRI 0.66 (0.50-0.82; p=0.07) and FIB-4 0.66 (0.49-0.82; p=0.07). CONCLUSION The ELF test less accurately discriminates severe fibrosis or cirrhosis when compared to LSM in our cohort of non-Asian women with CHB.
Collapse
Affiliation(s)
- S Harkisoen
- Department of Internal Medicine and Infectious Diseases, University Medical Center Utrecht, The Netherlands.
| | - G J Boland
- Department of Medical Microbiology, University Medical Center Utrecht, The Netherlands
| | - J A R van den Hoek
- Department of Infectious diseases, Public Health Service of Amsterdam (GGD), Amsterdam, The Netherlands; Department of Internal Medicine, Division of Infectious Diseases, Tropical Medicine and AIDS, Academic Medical Center, Amsterdam, The Netherlands
| | - K J van Erpecum
- Department of Gastroenterology and Hepatology, University Medical Center Utrecht, The Netherlands
| | - A I M Hoepelman
- Department of Internal Medicine and Infectious Diseases, University Medical Center Utrecht, The Netherlands
| | - J E Arends
- Department of Internal Medicine and Infectious Diseases, University Medical Center Utrecht, The Netherlands
| |
Collapse
|
96
|
Wang JH, Chuah SK, Lu SN, Hung CH, Kuo CM, Tai WC, Chiou SS. Baseline and serial liver stiffness measurement in prediction of portal hypertension progression for patients with compensated cirrhosis. Liver Int 2014; 34:1340-8. [PMID: 24620731 DOI: 10.1111/liv.12525] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2013] [Accepted: 03/05/2014] [Indexed: 12/16/2022]
Abstract
BACKGROUND & AIMS Liver stiffness measurement (LSM) using transient elastography is useful in prediction of significant portal hypertension (PHT). To evaluate the usefulness of baseline and serial LSM in predicting clinical disease progression (CDP) for patients with compensated hepatic cirrhosis. METHODS Consecutive patients with compensated cirrhosis and without hepatocellular carcinoma (HCC) were prospectively enrolled. Baseline LSM was assessed at enrolment, then at a 6- to 12-month interval. Esophagogastroduodenoscopy and ultrasonography were performed regularly for surveillance of varices and HCC, while CDP including HCC development and PHT progression was recorded. RESULTS Two hundred and twenty patients were enrolled. In a median follow-up of 36.9 months, CDP were detected in 49 patients including 30 PHT progression and 19 HCC developments. The cumulative incidence of CDP, PHT progression and HCC development at 3 years was 20.7%, 12.8% and 9.1% respectively. Multivariate analyses showed that baseline LSM was an independent predictor of PHT progression and CDP, however, not of HCC occurrence. The performance of baseline LSM in predicting PHT progression, varices growth/development and hepatic decompensation was 0.744, 0.638 and 0.929. With 17, 12 and 21.1 kPa as the cut-off, the negative predictive value was 92, 94 and 99% respectively. Patients with baseline LSM ≧17 kPa without serial changes had higher risk of PHT progression. CONCLUSION For patients with compensated cirrhosis, LSM was an independent predictor of PHT progression and CDP, but not of HCC occurrence. Baseline LSM was useful to exclude PHT progression. Patients with baseline and serial LSM ≧17 kPa had higher risk of PHT progression.
Collapse
Affiliation(s)
- Jing-Houng Wang
- Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | | | | | | | | | | | | |
Collapse
|
97
|
Abstract
INTRODUCTION Cirrhosis is a major milestone in patients with chronic liver disease because of its impact on patient morbidity and mortality. Chronic hepatitis B (CHB) and hepatitis C (CHC) are important causes of cirrhosis. This systematic review examines the relevant literature and evidence to assess whether cirrhosis can be reversible in patients with cirrhosis from viral hepatitis through long viral suppression. METHODS A MEDLINE and Cochrane Library search was conducted to identify all articles pertinent to the subject matter. Fourteen publications were included in the final analysis: 4 hepatitis B studies and 10 hepatitis C studies. Data abstracted from individual studies included patient demographics, antiviral therapy used, length of treatment, liver biopsy scoring system, length of biopsy, and time between biopsies. RESULTS In CHB, the 7 studies reviewed included a total of 463 cirrhotic patients. Regression of cirrhosis was noted in a median of 70% (range, 33% to 80%) of patients. In CHC, the 13 studies reviewed included a total of 58 cirrhotic patients. Regression of cirrhosis was seen in a median of 64% (range, 33% to 100%) of patients with sustained viral response. CONCLUSIONS The results of our review suggest that viral suppression in CHB and sustained virologic response in CHC can be associated with histologic regression of cirrhosis in select patients.
Collapse
|
98
|
De Robertis R, D’Onofrio M, Demozzi E, Crosara S, Canestrini S, Pozzi Mucelli R. Noninvasive diagnosis of cirrhosis: A review of different imaging modalities. World J Gastroenterol 2014; 20:7231-7241. [PMID: 24966594 PMCID: PMC4064069 DOI: 10.3748/wjg.v20.i23.7231] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2013] [Revised: 01/08/2014] [Accepted: 04/09/2014] [Indexed: 02/06/2023] Open
Abstract
Progressive hepatic fibrosis can lead to cirrhosis, so its early detection is fundamental. Staging fibrosis is also critical for prognosis and management. The gold standard for these aims is liver biopsy, but it has several drawbacks, as it is invasive, expensive, has poor acceptance, is prone to inter observer variability and sampling errors, has poor repeatability, and has a risk of complications and mortality. Therefore, non-invasive imaging tests have been developed. This review mainly focuses on the role of transient elastography, acoustic radiation force impulse imaging, and magnetic resonance-based methods for the noninvasive diagnosis of cirrhosis.
Collapse
|
99
|
Value of liver elastography and abdominal ultrasound for detection of complications of allogeneic hemopoietic SCT. Bone Marrow Transplant 2014; 49:806-11. [PMID: 24710567 DOI: 10.1038/bmt.2014.61] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2013] [Revised: 02/10/2014] [Accepted: 02/15/2014] [Indexed: 12/19/2022]
Abstract
Hepatic complications contribute to morbidity and mortality after allogeneic hemopoietic SCT. Liver Doppler ultrasound and elastography represent promising methods for pretransplant risk assessment and early detection of complications. Ultrasound (liver and spleen size, liver perfusion) and elastography (transient elastography (TE); right liver lobe acoustic radiation force impulse imaging (r-ARFI); left liver lobe ARFI (l-ARFI)) were prospectively evaluated in patients with indications for allo-SCT. Measurements were performed before and repeatedly after SCT. Results were compared with the incidence of life-threatening complications and death during the first 150 days after SCT. Of 59 included patients, 16 suffered from major complications and 9 of them died within the follow-up period. At baseline, liver and spleen size, liver perfusion, TE and r-ARFI did not differ significantly between patients with and without severe complications. In contrast, l-ARFI was significantly elevated in patients who later developed severe complications (1.58±0.30 m/s vs 1.37±0.27 m/s, P=0.030). After SCT, l-ARFI values remained elevated and TE showed increasing liver stiffness in patients with complications. The value of conventional liver ultrasound for prediction of severe SCT complications is limited. Increased values for TE and l-ARFI are associated with severe SCT complications and demand further evaluation.
Collapse
|
100
|
Saludes V, González V, Planas R, Matas L, Ausina V, Martró E. Tools for the diagnosis of hepatitis C virus infection and hepatic fibrosis staging. World J Gastroenterol 2014; 20:3431-3442. [PMID: 24707126 PMCID: PMC3974510 DOI: 10.3748/wjg.v20.i13.3431] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2013] [Revised: 12/05/2013] [Accepted: 03/06/2014] [Indexed: 02/06/2023] Open
Abstract
Hepatitis C virus (HCV) infection represents a major public health issue. Hepatitis C can be cured by therapy, but many infected individuals are unaware of their status. Effective HCV screening, fast diagnosis and characterization, and hepatic fibrosis staging are highly relevant for controlling transmission, treating infected patients and, consequently, avoiding end-stage liver disease. Exposure to HCV can be determined with high sensitivity and specificity with currently available third generation serology assays. Additionally, the use of point-of-care tests can increase HCV screening opportunities. However, active HCV infection must be confirmed by direct diagnosis methods. Additionally, HCV genotyping is required prior to starting any treatment. Increasingly, high-volume clinical laboratories use different types of automated platforms, which have simplified sample processing, reduced hands-on-time, minimized contamination risks and human error and ensured full traceability of results. Significant advances have also been made in the field of fibrosis stage assessment with the development of non-invasive methods, such as imaging techniques and serum-based tests. However, no single test is currently available that is able to completely replace liver biopsy. This review focuses on approved commercial tools used to diagnose HCV infection and the recommended hepatic fibrosis staging tests.
Collapse
|