1
|
Zhou H, Zhang Z, Zhang J, Sang L, Liu L, Gong X, Sun Y, Zheng Y, Yu M. Performance of spleen stiffness measurement by 2D-shear wave elastography in evaluating the presence of high-risk varices: comparative analysis of idiopathic portal hypertension versus hepatitis B virus. BMC Med Imaging 2023; 23:30. [PMID: 36759764 PMCID: PMC9909910 DOI: 10.1186/s12880-023-00977-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Accepted: 01/27/2023] [Indexed: 02/11/2023] Open
Abstract
BACKGROUND Noninvasive assessment of high-risk varices (HRV) in idiopathic portal hypertension (IPH) is rare. The purpose of this study was to investigate the performance of spleen stiffness (SS) for evaluating the presence of HRV in IPH patients as compared the measurements in patients with hepatitis B virus (HBV). METHODS A retrospective single-center study was performed to evaluate the performance of SS for assessing HRV in IPH and HBV-infected patients, in comparison with liver stiffness (LS), spleen stiffness-to-liver stiffness ratio (SS/LS), LS spleen-diameter-to-platelet-ratio score (LSPS), portal hypertension risk score (PH risk score) and varices risk score, by using upper gastrointestinal endoscopy (UGE) as the gold standard. Finally, 86 IPH and 102 HBV-infected patients were enrolled. UGE, two-dimensional shear wave elastography (2D-SWE) and laboratory data were collected, and noninvasive parameters were calculated. Analysis of receiver operating characteristic (ROC) curves was conducted to acquire the optimal area under the ROC curve (AUC) and cutoff value for predicting the presence of HRV. RESULTS In patients with HRV, the significantly different parameters between IPH (34.9%) and HBV-infected patients (46.1%) were as follows: spleen size (diameter 18.5 ± 3.9 cm vs. 20.8 ± 2.7 cm), SS (50.2 kPa vs. 42.9 kPa), LS (11.1 kPa vs. 18.3 kPa) and PT (prothrombin time 15.1 s vs. 16.7 s). No statistically significant differences were found in liver function, platelet counts, spleen thickness and flow volumes in the portal venous system (p > 0.05). The AUCs of SS were 0.98 and 0.96 for predicting the presence of HRV in IPH (44.0 kPa cutoff value; 0.93 sensitivity; 0.96 specificity) and HBV-infected patients (35.2 kPa cutoff value; 1.00 sensitivity; 0.82 specificity), respectively, which were significantly better than other parameters. CONCLUSION SS shows the optimal overall performance for predicting the presence of HRV in IPH and HBV-infected patients, in comparison with other noninvasive parameters.
Collapse
Affiliation(s)
- Huihui Zhou
- grid.417295.c0000 0004 1799 374XDepartment of Ultrasonic Medicine, The First Affiliated Hospital of Fourth Military Medical University, Xi’an, 710032 Shaanxi China
| | - Zhilin Zhang
- grid.417295.c0000 0004 1799 374XDepartment of Ultrasonic Medicine, The First Affiliated Hospital of Fourth Military Medical University, Xi’an, 710032 Shaanxi China
| | - Jun Zhang
- grid.417295.c0000 0004 1799 374XDepartment of Ultrasonic Medicine, The First Affiliated Hospital of Fourth Military Medical University, Xi’an, 710032 Shaanxi China
| | - Lin Sang
- grid.417295.c0000 0004 1799 374XDepartment of Ultrasonic Medicine, The First Affiliated Hospital of Fourth Military Medical University, Xi’an, 710032 Shaanxi China
| | - Lina Liu
- grid.417295.c0000 0004 1799 374XDepartment of Ultrasonic Medicine, The First Affiliated Hospital of Fourth Military Medical University, Xi’an, 710032 Shaanxi China
| | - Xue Gong
- grid.417295.c0000 0004 1799 374XDepartment of Ultrasonic Medicine, The First Affiliated Hospital of Fourth Military Medical University, Xi’an, 710032 Shaanxi China
| | - Yuanyuan Sun
- grid.417295.c0000 0004 1799 374XDepartment of Ultrasonic Medicine, The First Affiliated Hospital of Fourth Military Medical University, Xi’an, 710032 Shaanxi China
| | - Yu Zheng
- Department of Ultrasound, Xi'an Central Hospital, Xi'an, 710003, Shaanxi, China.
| | - Ming Yu
- Department of Ultrasonic Medicine, The First Affiliated Hospital of Fourth Military Medical University, Xi'an, 710032, Shaanxi, China.
| |
Collapse
|
2
|
Ichikawa H, Yasuda E, Kumada T, Takeshima K, Ogawa S, Tsunekawa A, Goto T, Nakaya K, Akita T, Tanaka J. Intra-individual comparison of liver stiffness measurements by magnetic resonance elastography and two-dimensional shear-wave elastography in 888 patients. Ultrasonography 2023; 42:65-77. [PMID: 36366945 PMCID: PMC9816707 DOI: 10.14366/usg.22052] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 06/21/2022] [Indexed: 11/13/2022] Open
Abstract
PURPOSE Quantitative elastography methods, such as ultrasound two-dimensional shear-wave elastography (2D-SWE) and magnetic resonance elastography (MRE), are used to diagnose liver fibrosis. The present study compared liver stiffness determined by 2D-SWE and MRE within individuals and analyzed the degree of agreement between the two techniques. METHODS In total, 888 patients who underwent 2D-SWE and MRE were analyzed. Bland-Altman analysis was performed after both types of measurements were log-transformed to a normal distribution and converted to a common set of units using linear regression analysis for differing scales. The expected limit of agreement (LoA) was defined as the square root of the sum of the squares of 2D-SWE and MRE precision. The percentage difference was expressed as (2D-SWEMRE)/ mean of the two methods×100. RESULTS A Bland-Altman plot showed that the bias and upper and lower LoAs (ULoA and LLoA) were 0.0002 (95% confidence interval [CI], -0.0057 to 0.0061), 0.1747 (95% CI, 0.1646 to 0.1847), and -0.1743 (95% CI, -0.1843 to -0.1642), respectively. In terms of percentage difference, the mean, ULoA, and LLoA were -0.5944%, 19.8950%, and -21.0838%, respectively. The calculated expected LoA was 17.1178% (95% CI, 16.6353% to 17.6002%), and 789 of 888 patients (88.9%) had a percentage difference within the expected LoA. The intraclass correlation coefficient of the two methods indicated an almost perfect correlation (0.8231; 95% CI, 0.8006 to 0.8432; P<0.001). CONCLUSION Bland-Altman analysis demonstrated that 2D-SWE and MRE were interchangeable within a clinically acceptable range.
Collapse
Affiliation(s)
- Hideo Ichikawa
- Department of Medical Imaging, Graduate School of Health Science, Suzuka University of Medical Science, Suzuka, Japan
| | - Eisuke Yasuda
- Department of Medical Imaging, Graduate School of Health Science, Suzuka University of Medical Science, Suzuka, Japan,Correspondence to: Eisuke Yasuda, PhD, Department of Medical Imaging, Graduate School of Health Science, Suzuka University of Medical Science, Suzuka, Mie 510- 0293, Japan Tel. +81-059-383-8991 Fax. +81-059-383-9666 E-mail:
| | - Takashi Kumada
- Department of Nursing, Faculty of Nursing, Gifu Kyoritsu University, Ogaki, Japan
| | - Kenji Takeshima
- Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Japan
| | - Sadanobu Ogawa
- Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Japan
| | - Akikazu Tsunekawa
- Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Japan
| | - Tatsuya Goto
- Department of Imaging Diagnosis, Ogaki Municipal Hospital, Ogaki, Japan
| | - Koji Nakaya
- Department of Medical Imaging, Graduate School of Health Science, Suzuka University of Medical Science, Suzuka, Japan
| | - Tomoyuki Akita
- Department of Epidemiology, Infectious Disease Control, and Prevention, Hiroshima University Institute of Biomedical and Health Sciences, Hiroshima, Japan
| | - Junko Tanaka
- Department of Epidemiology, Infectious Disease Control, and Prevention, Hiroshima University Institute of Biomedical and Health Sciences, Hiroshima, Japan
| |
Collapse
|
3
|
Nowotny F, Schmidberger J, Schlingeloff P, Binzberger A, Kratzer W. Comparison of point and two-dimensional shear wave elastography of the spleen in healthy subjects. World J Radiol 2021; 13:137-148. [PMID: 34141093 PMCID: PMC8188838 DOI: 10.4329/wjr.v13.i5.137] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 03/31/2021] [Accepted: 05/22/2021] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Few systematic comparative studies of the different methods of physical elastography of the spleen are currently available.
AIM To compare point shear wave and two-dimensional elastography of the spleen considering the anatomical location (upper, hilar, and lower pole).
METHODS As part of a prospective clinical study, healthy volunteers were examined for splenic elasticity using four different ultrasound devices between May 2015 and April 2017. The devices used for point shear wave elastography were from Siemens (S 3000) and Philips (Epiq 7), and those used for two-dimensional shear wave elastography were from GE (Logiq E9) and Toshiba (Aplio 500). In addition, two different software versions (5.0 and 6.0) were evaluated for the Toshiba ultrasound device (Aplio 500). The study consisted of three arms: A, B, and C.
RESULTS In study arm A, 200 subjects were evaluated (78 males and 122 females, mean age 27.9 ± 8.1 years). In study arm B, 113 subjects were evaluated (38 men and 75 women, mean age 26.0 ± 6.3 years). In study arm C, 44 subjects were enrolled. A significant correlation of the shear wave velocities at the upper third of the spleen (r = 0.33088, P < 0.0001) was demonstrated only for the Philips Epiq 7 device compared to the Siemens Acuson S 3000. In comparisons of the other ultrasound devices (GE, Siemens, Toshiba), no comparable results could be obtained for any anatomical position of the spleen. The influencing factors age, gender, and body mass index did not show a clear correlation with the measured shear wave velocities.
CONCLUSION The absolute values of the shear wave elastography measurements of the spleen and the two different elastography methods are not comparable between different manufacturers or models.
Collapse
Affiliation(s)
- Friederike Nowotny
- Department of Internal Medicine I, University Hospital Ulm, Ulm 89081, Germany
| | - Julian Schmidberger
- Department of Internal Medicine I, University Hospital Ulm, Ulm 89081, Germany
| | | | - Andreas Binzberger
- Department of Internal Medicine I, University Hospital Ulm, Ulm 89081, Germany
| | - Wolfgang Kratzer
- Department of Internal Medicine I, University Hospital Ulm, Ulm 89081, Germany
| |
Collapse
|
4
|
Chen S, Jiang T. Preoperative noninvasive assessment for liver fibrosis in hepatocellular carcinoma patients with chronic hepatitis B: Comparison of two-dimensional shear-wave elastography with serum liver fibrosis models. Eur J Radiol 2020; 133:109386. [PMID: 33160197 DOI: 10.1016/j.ejrad.2020.109386] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2020] [Revised: 10/20/2020] [Accepted: 10/26/2020] [Indexed: 12/24/2022]
Abstract
PURPOSE To investigate the diagnostic performance of two-dimensional shear-wave elastography (2D-SWE) in hepatocellular carcinoma patients with chronic hepatitis B adapted to hepatectomy comparing to serum liver fibrosis models. METHOD 100 patients with chronic hepatitis B who first diagnosed with hepatocellular carcinoma and had undergone 2D-SWE measurements before the hepatectomy were included. The performance of 2D-SWE and serum models in the diagnosis of liver fibrosis was assessed using receiver operating characteristic (ROC) analyses. RESULTS The areas under ROC (AUCs) for 2D-SWE, Forns score, aspartate transaminase-to-platelet ratio index (APRI) and Fibrosis 4 Score (FIB-4) were 0.983, 0.757, 0.745, 0.710 in the diagnosis of significant fibrosis (F ≥ 2) respectively, and 0.896, 0.718, 0.626, 0.575 in the diagnosis of cirrhosis (F = 4) respectively. The AUCs for 2D-SWE in the diagnosis of significant fibrosis and cirrhosis were significantly higher than those for the serum fibrosis models (p < 0.05). The AUCs of Forns in the diagnosis of significant fibrosis (F ≥ 2) showed no statistical differences (p > 0.05) with those of APRI and FIB-4 while in the diagnosis of cirrhosis (F = 4), they are significantly higher (p < 0.05). CONCLUSIONS 2D-SWE is a reliable method for preoperative noninvasive assessment of liver fibrosis in HCC patients with CHB, with notably higher diagnostic accuracy than serum liver fibrosis models.
Collapse
Affiliation(s)
- Shuochun Chen
- Department of Ultrasound, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China.
| | - Tian'an Jiang
- Department of Ultrasound, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China.
| |
Collapse
|
5
|
Şirli R, Sporea I, Popescu A, Dănilă M. Ultrasound-based elastography for the diagnosis of portal hypertension in cirrhotics. World J Gastroenterol 2015; 21:11542-11551. [PMID: 26556985 PMCID: PMC4631959 DOI: 10.3748/wjg.v21.i41.11542] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2015] [Revised: 07/11/2015] [Accepted: 08/31/2015] [Indexed: 02/06/2023] Open
Abstract
Progressive fibrosis is encountered in almost all chronic liver diseases. Its clinical signs are diagnostic in advanced cirrhosis, but compensated liver cirrhosis is harder to diagnose. Liver biopsy is still considered the reference method for staging the severity of fibrosis, but due to its drawbacks (inter and intra-observer variability, sampling errors, unequal distribution of fibrosis in the liver, and risk of complications and even death), non-invasive methods were developed to assess fibrosis (serologic and elastographic). Elastographic methods can be ultrasound-based or magnetic resonance imaging-based. All ultrasound-based elastographic methods are valuable for the early diagnosis of cirrhosis, especially transient elastography (TE) and acoustic radiation force impulse (ARFI) elastography, which have similar sensitivities and specificities, although ARFI has better feasibility. TE is a promising method for predicting portal hypertension in cirrhotic patients, but it cannot replace upper digestive endoscopy. The diagnostic accuracy of using ARFI in the liver to predict portal hypertension in cirrhotic patients is debatable, with controversial results in published studies. The accuracy of ARFI elastography may be significantly increased if spleen stiffness is assessed, either alone or in combination with liver stiffness and other parameters. Two-dimensional shear-wave elastography, the ElastPQ technique and strain elastography all need to be evaluated as predictors of portal hypertension.
Collapse
|