51
|
Liang J, Liu F, Wang F, Han T, Jing L, Ma Z, Gao Y. A Noninvasive Score Model for Prediction of NASH in Patients with Chronic Hepatitis B and Nonalcoholic Fatty Liver Disease. BIOMED RESEARCH INTERNATIONAL 2017; 2017:8793278. [PMID: 28349067 PMCID: PMC5352864 DOI: 10.1155/2017/8793278] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2016] [Revised: 01/17/2017] [Accepted: 01/19/2017] [Indexed: 02/06/2023]
Abstract
Aims. To develop a noninvasive score model to predict NASH in patients with combined CHB and NAFLD. Objective and Methods. 65 CHB patients with NAFLD were divided into NASH group (34 patients) and non-NASH group (31 patients) according to the NAS score. Biochemical indexes, liver stiffness, and Controlled Attenuation Parameter (CAP) were determined. Data in the two groups were compared and subjected to multivariate analysis, to establish a score model for the prediction of NASH. Results. In the NASH group, ALT, TG, fasting blood glucose (FBG), M30 CK-18, CAP, and HBeAg positive ratio were significantly higher than in the non-NASH group (P < 0.05). Multivariate analysis showed that CK-18 M30, CAP, FBG, and HBVDNA level were independent predictors of NASH. Therefore, a new model combining CK18 M30, CAP, FBG, and HBVDNA level was established using logistic regression. The AUROC curve predicting NASH was 0.961 (95% CI: 0.920-1.00, cutoff value is 0.218), with a sensitivity of 100% and specificity of 80.6%. Conclusion. A noninvasive score model might be considered for the prediction of NASH in patients with CHB combined with NAFLD.
Collapse
Affiliation(s)
- Jing Liang
- Department of Gastroenterology and Hepatology, Tianjin Third Central Hospital, Tianjin 300170, China
- Tianjin Key Laboratory of Artificial Cell, Tianjin 300170, China
- Artificial Cell Engineering Technology Research Center of Public Health Ministry, Tianjin 300170, China
| | - Fang Liu
- Department of Gastroenterology and Hepatology, Tianjin Third Central Hospital, Tianjin 300170, China
- Tianjin Key Laboratory of Artificial Cell, Tianjin 300170, China
- Artificial Cell Engineering Technology Research Center of Public Health Ministry, Tianjin 300170, China
| | - Fengmei Wang
- Department of Gastroenterology and Hepatology, Tianjin Third Central Hospital, Tianjin 300170, China
- Tianjin Key Laboratory of Artificial Cell, Tianjin 300170, China
- Artificial Cell Engineering Technology Research Center of Public Health Ministry, Tianjin 300170, China
| | - Tao Han
- Department of Gastroenterology and Hepatology, Tianjin Third Central Hospital, Tianjin 300170, China
- Tianjin Key Laboratory of Artificial Cell, Tianjin 300170, China
- Artificial Cell Engineering Technology Research Center of Public Health Ministry, Tianjin 300170, China
| | - Li Jing
- Tianjin Key Laboratory of Artificial Cell, Tianjin 300170, China
- Artificial Cell Engineering Technology Research Center of Public Health Ministry, Tianjin 300170, China
- Molecular Biology Laboratory, Tianjin Third Central Hospital, Tianjin 300170, China
| | - Zhe Ma
- Department of Pathology, Tianjin Third Central Hospital, Tianjin 300170, China
| | - Yingtang Gao
- Tianjin Key Laboratory of Artificial Cell, Tianjin 300170, China
- Artificial Cell Engineering Technology Research Center of Public Health Ministry, Tianjin 300170, China
- Molecular Biology Laboratory, Tianjin Third Central Hospital, Tianjin 300170, China
| |
Collapse
|
52
|
Chan WK, Nik Mustapha NR, Wong GLH, Wong VWS, Mahadeva S. Controlled attenuation parameter using the FibroScan® XL probe for quantification of hepatic steatosis for non-alcoholic fatty liver disease in an Asian population. United European Gastroenterol J 2017; 5:76-85. [PMID: 28405325 PMCID: PMC5384552 DOI: 10.1177/2050640616646528] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2016] [Accepted: 04/03/2016] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND The FibroScan® XL probe reduces failure of liver stiffness measurement (LSM) and unreliable results in obese patients. OBJECTIVE The objective of this article is to evaluate the accuracy of controlled attenuation parameter (CAP) obtained using the XL probe for the estimation of hepatic steatosis in patients with non-alcoholic fatty liver disease (NAFLD). METHODS Adult NAFLD patients with a liver biopsy within six months were included and were examined with the FibroScan® M and XL probes. Histopathological findings were reported according to the Non-Alcoholic Steatohepatitis Clinical Research Network Scoring System. Participants who did not have fatty liver on ultrasonography were recruited as controls. RESULTS A total of 57 NAFLD patients and 22 controls were included. The mean age of the NAFLD patients and controls was 50.1 ± 10.4 years and 20.2 ± 1.3 years, respectively (p = 0.000). The mean body mass index was 30.2 ± 5.0 kg per m2 and 20.5 ± 2.4 kg per m2, respectively (p = 0.000). The distribution of steatosis grades were: S0, 29%; S1, 17%; S2, 35%; S3, 19%. The AUROC for estimation of steatosis grade ≥ S1, S2 and S3 was 0.94, 0.80 and 0.69, respectively, using the M probe, and 0.97, 0.81 and 0.67, respectively, using the XL probe. CONCLUSION CAP obtained using the XL probe had similar accuracy as the M probe for the estimation of hepatic steatosis in NAFLD patients.
Collapse
Affiliation(s)
- Wah-Kheong Chan
- Department of Medicine, Faculty of Medicine, University of Malaya, Malaysia
| | | | - Grace Lai-Hung Wong
- Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong
| | - Vincent Wai-Sun Wong
- Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong
| | - Sanjiv Mahadeva
- Department of Medicine, Faculty of Medicine, University of Malaya, Malaysia
| |
Collapse
|
53
|
Hodge A, Lim S, Goh E, Wong O, Marsh P, Knight V, Sievert W, de Courten B. Coffee Intake Is Associated with a Lower Liver Stiffness in Patients with Non-Alcoholic Fatty Liver Disease, Hepatitis C, and Hepatitis B. Nutrients 2017; 9:nu9010056. [PMID: 28075394 PMCID: PMC5295100 DOI: 10.3390/nu9010056] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Revised: 01/02/2017] [Accepted: 01/05/2017] [Indexed: 01/15/2023] Open
Abstract
There is emerging evidence for the positive effects or benefits of coffee in patients with liver disease. We conducted a retrospective cross-sectional study on patients with non-alcoholic fatty liver disease (NAFLD), hepatitis C virus (HCV), and hepatitis B virus (HBV) infection to determine the effects of coffee intake on a non-invasive marker of liver fibrosis: liver stiffness assessed by transient elastography (TE). We assessed coffee and tea intake and measured TE in 1018 patients with NAFLD, HCV, and HBV (155 with NAFLD, 378 with HCV and 485 with HBV). Univariate and multivariate regression models were performed taking into account potential confounders. Liver stiffness was higher in males compared to females (p < 0.05). Patients with HBV had lower liver stiffness than those with HCV and NAFLD. After adjustment for age, gender, smoking, alcohol consumption, M or XL probe, and disease state (NAFLD, HCV, and HBV status), those who drank 2 or more cups of coffee per day had a lower liver stiffness (p = 0.044). Tea consumption had no effect (p = 0.9). Coffee consumption decreases liver stiffness, which may indicate less fibrosis and inflammation, independent of disease state. This study adds further evidence to the notion of coffee maybe beneficial in patients with liver disease.
Collapse
Affiliation(s)
- Alexander Hodge
- Gastroenterology and Hepatology Unit, Monash Health, Melbourne 3168, Australia.
- Centre for Inflammatory Disease, School of Clinical Sciences, Monash University, Melbourne 3168, Australia.
| | - Sarah Lim
- School of Clinical Sciences, Monash University, Melbourne 3168, Australia.
| | - Evan Goh
- School of Clinical Sciences, Monash University, Melbourne 3168, Australia.
| | - Ophelia Wong
- School of Clinical Sciences, Monash University, Melbourne 3168, Australia.
| | - Philip Marsh
- School of Clinical Sciences, Monash University, Melbourne 3168, Australia.
| | - Virginia Knight
- Gastroenterology and Hepatology Unit, Monash Health, Melbourne 3168, Australia.
| | - William Sievert
- Gastroenterology and Hepatology Unit, Monash Health, Melbourne 3168, Australia.
- Centre for Inflammatory Disease, School of Clinical Sciences, Monash University, Melbourne 3168, Australia.
| | - Barbora de Courten
- Monash Centre for Health, Research and Implementation, School of Public Health and Preventive Medicine, Monash University, Melbourne 3168, Australia.
| |
Collapse
|
54
|
Andrade P, Rodrigues S, Rodrigues-Pinto E, Gaspar R, Lopes J, Lopes S, Macedo G. Diagnostic Accuracy of Controlled Attenuation Parameter for Detecting Hepatic Steatosis in Patients with Chronic Liver Disease. GE-PORTUGUESE JOURNAL OF GASTROENTEROLOGY 2016; 24:161-168. [PMID: 29255745 DOI: 10.1159/000453364] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Revised: 11/11/2016] [Indexed: 12/11/2022]
Abstract
Introduction Controlled attenuation parameter (CAP), measured by transient elastography, has been suggested as a noninvasive method for the detection and quantification of steatosis. We aimed to assess the accuracy of CAP to detect steatosis in patients with chronic liver disease (CLD) compared with liver histology and to evaluate factors that correlate with the CAP value. Methods Patients with CLD who underwent liver biopsy and simultaneous CAP determination were consecutively enrolled. CAP was measured using the M probe of FibroScan® (Echosens, Paris, France). Histologically, steatosis was categorized as absent (S0: <5%), mild (S1: 5-33%), moderate (S2: 34-66%) and severe (S3: >66% of all hepatocytes). Results We analyzed 159 patients with CLD (61% men, mean age 47.9 ± 12.9 years). We found a positive correlation between CAP and steatosis in histology (rs = 0.869, p < 0.001), arterial hypertension (rs = 0.222, p = 0.005), type 2 diabetes mellitus (rs = 0.279, p < 0.001), body mass index (BMI; rs = 0.533, p < 0.001), total cholesterol (rs = 0.442, p < 0.001), triglycerides (rs = 0.272, p = 0.001), and non-alcoholic fatty liver disease (NAFLD; rs = 0.588, p < 0.001). In the multivariate analysis, BMI >25 (odds ratio [OR] 48.4, 95% confidence interval [CI] 23.78-72.95, p < 0.001), serum total cholesterol (OR 3.803, 95% CI 2.203-13.889, p = 0.008), and NAFLD etiology (OR 40.8, 95% CI 15.01-66.66, p = 0.002) were independently associated with higher CAP values. We did not find any significant correlation between CAP and the grade of necroinflammatory activity (rs = 0.063, p = 0.808) or fibrosis (rs = 0.071, p = 0.713) in histology and with alanine aminotransferase (rs = 0.190, p = 0.356) or aspartate aminotransferase (rs = 0.117, p = 0.142). Optimal CAP cutoff values for detecting steatosis ≥S1, ≥S2, and ≥S3 were 206.5, 232.5, and 282.5 dB/m, respectively. CAP performance was 0.822, 0.956, and 0.976 for diagnosing steatosis ≥S1, ≥S2, and ≥S3, respectively. Conclusions CAP had an excellent diagnostic accuracy for the detection of steatosis in diverse CLD patients. A CAP value cutoff of <282.5 dB/m excludes severe steatosis ≥S3 with an accuracy of 98%.
Collapse
Affiliation(s)
- Patrícia Andrade
- Department of Gastroenterology, Faculty of Medicine, Centro Hospitalar São João, University of Porto, Porto, Portugal
| | - Susana Rodrigues
- Department of Gastroenterology, Faculty of Medicine, Centro Hospitalar São João, University of Porto, Porto, Portugal
| | - Eduardo Rodrigues-Pinto
- Department of Gastroenterology, Faculty of Medicine, Centro Hospitalar São João, University of Porto, Porto, Portugal
| | - Rui Gaspar
- Department of Gastroenterology, Faculty of Medicine, Centro Hospitalar São João, University of Porto, Porto, Portugal
| | - Joanne Lopes
- Department of Pathology, Faculty of Medicine, Centro Hospitalar São João, University of Porto, Porto, Portugal
| | - Susana Lopes
- Department of Gastroenterology, Faculty of Medicine, Centro Hospitalar São João, University of Porto, Porto, Portugal
| | - Guilherme Macedo
- Department of Gastroenterology, Faculty of Medicine, Centro Hospitalar São João, University of Porto, Porto, Portugal
| |
Collapse
|
55
|
Ahn JM, Paik YH, Min SY, Cho JY, Sohn W, Sinn DH, Gwak GY, Choi MS, Lee JH, Koh KC, Paik SW, Yoo BC. Relationship between Controlled Attenuation Parameter and Hepatic Steatosis as Assessed by Ultrasound in Alcoholic or Nonalcoholic Fatty Liver Disease. Gut Liver 2016; 10:295-302. [PMID: 26347511 PMCID: PMC4780461 DOI: 10.5009/gnl15155] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Background/Aims The aim of this study was to evaluate the relationship between controlled attenuation parameter (CAP) and hepatic steatosis, as assessed by ultrasound (US) in patients with alcoholic liver disease (ALD) or non-alcoholic fatty liver disease (NAFLD). Methods Patients with either ALD or NAFLD who were diagnosed with fatty liver with US and whose CAP scores were measured, were retrospectively enrolled in this study. The degree of hepatic steatosis assessed by US was categorized into mild (S1), moderate (S2), and severe (S3). Results A total of 186 patients were included: 106 with NAFLD and 80 with ALD. Regarding hepatic steatosis, the CAP score was significantly correlated with US (ρ=0.580, p<0.001), and there was no significant difference between the NAFLD and ALD groups (ρ=0.569, p<0.001; ρ=0.519, p<0.001; p=0.635). Using CAP, area under receiver operating characteristic curves for ≥S2 and ≥S3 steatosis were excellent (0.789 and 0.843, respectively). For sensitivity ≥90%, CAP cutoffs for the detection of ≥S2 and ≥S3 steastosis were separated with a gap of approximately 35 dB/m in all patients and in each of the NAFLD and ALD groups. Conclusions The CAP score is well correlated with hepatic steatosis, as assessed by US, in both ALD and NAFLD.
Collapse
Affiliation(s)
- Jem Ma Ahn
- Division of Gastroenterology and Hepatology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Yong-Han Paik
- Division of Gastroenterology and Hepatology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Sin Yeong Min
- Division of Gastroenterology and Hepatology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Ju Yeon Cho
- Division of Gastroenterology and Hepatology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Won Sohn
- Division of Gastroenterology and Hepatology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Dong Hyun Sinn
- Division of Gastroenterology and Hepatology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Geum-Youn Gwak
- Division of Gastroenterology and Hepatology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Moon Seok Choi
- Division of Gastroenterology and Hepatology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Joon Hyeok Lee
- Division of Gastroenterology and Hepatology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Kwang Cheol Koh
- Division of Gastroenterology and Hepatology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Seung Woon Paik
- Division of Gastroenterology and Hepatology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Byung Chul Yoo
- Division of Gastroenterology and Hepatology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|
56
|
Ferraioli G, Tinelli C, De Silvestri A, Lissandrin R, Above E, Dellafiore C, Poma G, Di Gregorio M, Maiocchi L, Maserati R, Filice C. The clinical value of controlled attenuation parameter for the noninvasive assessment of liver steatosis. Liver Int 2016; 36:1860-1866. [PMID: 27439331 DOI: 10.1111/liv.13207] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Accepted: 07/13/2016] [Indexed: 02/06/2023]
Abstract
BACKGROUND & AIMS Ultrasound is the imaging modality most widely utilized in the general population for diagnostic purposes. Controlled attenuation parameter is a novel noninvasive method for assessing steatosis. Our aim was to investigate whether the clinical value of controlled attenuation parameter in patients referred for abdominal ultrasound examinations is affected by liver fibrosis. METHODS Consecutive patients referred for abdominal ultrasound examinations were enrolled. Controlled attenuation parameter and liver stiffness were assessed with the FibroScan (Echosens, France). Liver fibrosis was staged according to published cutoffs of liver stiffness measurements. Pearson's or Spearman's rank correlation coefficient was used to test the association between two study variables. Optimal cutoff of controlled attenuation parameter for diagnosing liver steatosis (S≥2) was 256 dB/m. The diagnostic performance and accuracy of dichotomized controlled attenuation parameter, ultrasound and body mass index were analysed using the imperfect gold standard methodology. RESULTS A total of 726 subjects (464 males and 262 females) were studied. Five hundred and eight-nine (81.1%) patients were affected by chronic viral hepatitis. Correlation of controlled attenuation parameter with ultrasound score was 0.48 and 0.57 in patients with and without chronic viral hepatitis respectively. In patients with chronic viral hepatitis, ultrasound, dichotomized controlled attenuation parameter and body mass index showed performance of 58.2%, 82.3% and 46.7%, respectively, whereas in patients without chronic viral hepatitis, the performance was 86.4%, 68.6% and 48.6% respectively. CONCLUSIONS In patients with chronic viral hepatitis and advanced liver fibrosis, controlled attenuation parameter performs better than ultrasound for assessing liver steatosis, whereas in patients without viral hepatitis and with nonsignificant liver disease ultrasound shows the best performance.
Collapse
Affiliation(s)
- Giovanna Ferraioli
- Department of Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy
| | - Carmine Tinelli
- Clinical Epidemiology and Biometric Unit, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
| | - Annalisa De Silvestri
- Clinical Epidemiology and Biometric Unit, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
| | - Raffaella Lissandrin
- Department of Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy
| | - Elisabetta Above
- Department of Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy
| | - Carolina Dellafiore
- Department of Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy
| | - Gianluigi Poma
- Department of Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy
| | - Marta Di Gregorio
- Department of Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy
| | - Laura Maiocchi
- Department of Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy
| | - Renato Maserati
- Department of Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy
| | - Carlo Filice
- Department of Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy
| |
Collapse
|
57
|
Abstract
Non-invasive diagnosis and quantification of hepatic steatosis rely on two different but complementary approaches: biomarkers or imaging techniques, either ultrasound-based such as liver ultrasonography and controlled attenuation parameter (CAP), or computed tomography (CT) and magnetic resonance imaging (MRI). Scores for the detection of steatosis have not gained much popularity in clinical practice so far. CAP, using the M probe, is the most promising technique but needs to be implemented with the XL probe and compared to ultrasound that, despite its limitations, remains the most widely used method. CT, owing to its low sensitivity and the fact that it involves a potential radiation hazard, is inappropriate. Finally, proton density fat fraction measurement by MRI is currently the most accurate and sensitive imaging method, simpler and more practical than magnetic resonance spectroscopy, but restricted, up to now, just to research and clinical trials.
Collapse
|
58
|
Mikolasevic I, Orlic L, Franjic N, Hauser G, Stimac D, Milic S. Transient elastography (FibroScan(®)) with controlled attenuation parameter in the assessment of liver steatosis and fibrosis in patients with nonalcoholic fatty liver disease - Where do we stand? World J Gastroenterol 2016; 22:7236-7251. [PMID: 27621571 PMCID: PMC4997649 DOI: 10.3748/wjg.v22.i32.7236] [Citation(s) in RCA: 197] [Impact Index Per Article: 21.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Revised: 06/28/2016] [Accepted: 08/01/2016] [Indexed: 02/06/2023] Open
Abstract
Non-alcoholic fatty liver disease (NAFLD) is the most common cause of chronic liver disease worldwide. Currently, the routinely used modalities are unable to adequately determine the levels of steatosis and fibrosis (laboratory tests and ultrasonography) or cannot be applied as a screening procedure (liver biopsy). Among the non-invasive tests, transient elastography (FibroScan(®), TE) with controlled attenuation parameter (CAP) has demonstrated good accuracy in quantifying the levels of liver steatosis and fibrosis in patients with NAFLD, the factors associated with the diagnosis and NAFLD progression. The method is fast, reliable and reproducible, with good intra- and interobserver levels of agreement, thus allowing for population-wide screening and disease follow-up. The initial inability of the procedure to accurately determine fibrosis and steatosis in obese patients has been addressed with the development of the obese-specific XL probe. TE with CAP is a viable alternative to ultrasonography, both as an initial assessment and during follow-up of patients with NAFLD. Its ability to exclude patients with advanced fibrosis may be used to identify low-risk NAFLD patients in whom liver biopsy is not needed, therefore reducing the risk of complications and the financial costs.
Collapse
|
59
|
Deng H, Wang CL, Lai J, Yu SL, Xie DY, Gao ZL. Noninvasive Diagnosis of Hepatic Steatosis Using Fat Attenuation Parameter Measured by FibroTouch and a New Algorithm in CHB Patients. HEPATITIS MONTHLY 2016; 16:e40263. [PMID: 27822268 PMCID: PMC5088638 DOI: 10.5812/hepatmon.40263] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/23/2016] [Accepted: 06/28/2016] [Indexed: 12/11/2022]
Abstract
BACKGROUND Chronic hepatitis B (CHB) remains a major public health problem worldwide, and the prevalence of CHB patients with hepatic steatosis is gradually increasing. Noninvasive approaches for the assessment of hepatic steatosis have been developed as alternatives to liver biopsy. OBJECTIVES This study evaluated the diagnostic performance of the fat attenuation parameter (FAP) measured by transient elastography (FibroTouch) and a new algorithm to assess hepatic steatosis in CHB patients, in comparison to liver biopsy as the gold standard. METHODS Two hundred fifty-four CHB patients underwent simultaneous liver biopsy, biochemical blood testing, and FibroTouch examination. A new algorithm based on four factors (FAP; body mass index, BMI; high-density lipoprotein, HDL; apolipoprotein B, APOB) was defined as follows: fatty index = 10*ep/ (1+ep), and P = -2.75 + 0.028 ln FAP (dB/m) + 0.409 ln BMI (Kg/m2) - 2.482 ln HDL (mmol/L) + 1.979 ln APOB (g/L). The performances of FAP and fatty index were assessed by area under the ROC curve (AUROC). RESULTS The difference in FAP was significant (P < 0.001) between CHB-only patients and CHB patients with hepatic steatosis. The cytokeratin 18 fragment (CK18-M65) level was significantly higher in CHB patients with non-alcoholic steatohepatitis (NASH) compared with CHB patients without NASH (P < 0.05). The optimal cutoff FAP values for hepatic steatosis of > 0, ≥ 5%, ≥ 10%, ≥ 20%, and ≥ 30% were 224.1, 230.6, 235.5, 246.9, and 261.1 dB/m, and AUROCs were 0.833, 0.801, 0.915, 0.917, and 0.972, respectively. The optimal cutoff value of fatty index for the diagnosis of hepatic steatosis was 1.5 and the AUROC was 0.807. CONCLUSIONS FAP is an accurate, reliable, and noninvasive approach that can also be combined with other metabolic biomarkers to comprehensively detect and quantify hepatic steatosis.
Collapse
Affiliation(s)
- Hong Deng
- Department of Infectious Diseases, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
- Corresponding Author: Hong Deng, Department of Infectious Diseases, Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China. Tel: +86-02085252063, Fax: +86-02085252372, E-mail:
| | - Chun-Ling Wang
- Department of Infectious Diseases, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
- Department of Hepatology, Huizhou Municipal Central Hospital, Hui Zhou, China
| | - Jing Lai
- Department of Infectious Diseases, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| | - Su-Lin Yu
- Department of Infectious Diseases, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| | - Dong-Ying Xie
- Department of Infectious Diseases, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| | - Zhi-Liang Gao
- Department of Infectious Diseases, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
60
|
Chon YE, Kim KJ, Jung KS, Kim SU, Park JY, Kim DY, Ahn SH, Chon CY, Chung JB, Park KH, Bae JC, Han KH. The Relationship between Type 2 Diabetes Mellitus and Non-Alcoholic Fatty Liver Disease Measured by Controlled Attenuation Parameter. Yonsei Med J 2016; 57:885-892. [PMID: 27189281 PMCID: PMC4951464 DOI: 10.3349/ymj.2016.57.4.885] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2015] [Revised: 09/21/2015] [Accepted: 10/17/2015] [Indexed: 01/02/2023] Open
Abstract
PURPOSE The severity of non-alcoholic fatty liver disease (NAFLD) in type 2 diabetes mellitus (T2DM) population compared with that in normal glucose tolerance (NGT) individuals has not yet been quantitatively assessed. We investigated the prevalence and the severity of NAFLD in a T2DM population using controlled attenuation parameter (CAP). MATERIALS AND METHODS Subjects who underwent testing for biomarkers related to T2DM and CAP using Fibroscan® during a regular health check-up were enrolled. CAP values of 250 dB/m and 300 dB/m were selected as the cutoffs for the presence of NAFLD and for moderate to severe NAFLD, respectively. Biomarkers related to T2DM included fasting glucose/insulin, fasting C-peptide, hemoglobin A1c (HbA1c), glycoalbumin, and homeostasis model assessment of insulin resistance of insulin resistance (HOMA-IR). RESULTS Among 340 study participants (T2DM, n=66; pre-diabetes, n=202; NGT, n=72), the proportion of subjects with NAFLD increased according to the glucose tolerance status (31.9% in NGT; 47.0% in pre-diabetes; 57.6% in T2DM). The median CAP value was significantly higher in subjects with T2DM (265 dB/m) than in those with pre-diabetes (245 dB/m) or NGT (231 dB/m) (all p<0.05). Logistic regression analysis showed that subjects with moderate to severe NAFLD had a 2.8-fold (odds ratio) higher risk of having T2DM than those without NAFLD (p=0.02; 95% confidence interval, 1.21-6.64), and positive correlations between the CAP value and HOMA-IR (ρ0.407) or fasting C-peptide (ρ0.402) were demonstrated. CONCLUSION Subjects with T2DM had a higher prevalence of severe NAFLD than those with NGT. Increased hepatic steatosis was significantly associated with the presence of T2DM, and insulin resistance induced by hepatic fat may be an important mechanistic connection.
Collapse
Affiliation(s)
- Young Eun Chon
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Liver Cirrhosis Clinical Research Center, Seoul, Korea
| | - Kwang Joon Kim
- Division of Endocrinology and Metabolism, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
- Executive Healthcare Clinic, Severance Hospital, Yonsei Health System, Seoul, Korea
| | - Kyu Sik Jung
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Liver Cirrhosis Clinical Research Center, Seoul, Korea
| | - Seung Up Kim
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Liver Cirrhosis Clinical Research Center, Seoul, Korea
| | - Jun Yong Park
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Liver Cirrhosis Clinical Research Center, Seoul, Korea
| | - Do Young Kim
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Liver Cirrhosis Clinical Research Center, Seoul, Korea
| | - Sang Hoon Ahn
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Liver Cirrhosis Clinical Research Center, Seoul, Korea
| | - Chae Yoon Chon
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Liver Cirrhosis Clinical Research Center, Seoul, Korea
| | - Jae Bock Chung
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Liver Cirrhosis Clinical Research Center, Seoul, Korea
- Executive Healthcare Clinic, Severance Hospital, Yonsei Health System, Seoul, Korea
| | - Kyeong Hye Park
- Executive Healthcare Clinic, Severance Hospital, Yonsei Health System, Seoul, Korea
| | - Ji Cheol Bae
- Division of Endocrinology and Metabolism, Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Kwang Hyub Han
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Liver Cirrhosis Clinical Research Center, Seoul, Korea.
| |
Collapse
|
61
|
Desai NK, Harney S, Raza R, Al-Ibraheemi A, Shillingford N, Mitchell PD, Jonas MM. Comparison of Controlled Attenuation Parameter and Liver Biopsy to Assess Hepatic Steatosis in Pediatric Patients. J Pediatr 2016; 173:160-164.e1. [PMID: 27039224 PMCID: PMC5105890 DOI: 10.1016/j.jpeds.2016.03.021] [Citation(s) in RCA: 91] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2015] [Revised: 01/25/2016] [Accepted: 03/01/2016] [Indexed: 12/18/2022]
Abstract
OBJECTIVE To assess whether the degree of steatosis as determined by controlled attenuation parameter (CAP) measurements correlates with that observed on liver biopsies in a single-center pediatric and young adult cohort. STUDY DESIGN This cross-sectional study included patients undergoing liver biopsy as part of standard clinical care between January 25, 2012, and April 1, 2015, at Boston Children's Hospital. Eligible patients, with a variety of liver diseases, had CAP measurements within 1 year of biopsy. CAP values were compared across histologic steatosis grades using ANOVA. RESULTS Sixty-nine patients (mean age, 16.0 ± 2.9 years; 62% male) were studied. CAP measurements were obtained at a median of 1.3 months (IQR, 0.5-3.2) after biopsy. Of the 69 subjects, 23 had steatosis on biopsy. Mean CAP value (dB/m) for subjects with no steatosis was 198 ± 37 vs 290 ± 47 for subjects with steatosis (P < .0001). There were statistically significant differences between CAP values in individuals with no steatosis vs mild/moderate steatosis (P < .0001), no steatosis vs marked steatosis (P < .0001), and mild/moderate vs marked steatosis (P = .004). CONCLUSION This study demonstrated a difference in CAP between no steatosis and steatosis, and between grades of steatosis. CAP may be a useful noninvasive tool to detect hepatic steatosis in children.
Collapse
Affiliation(s)
- Nirav K. Desai
- Division of Gastroenterology, Hepatology and Nutrition, Boston Children’s Hospital, Boston, MA
| | - Sarah Harney
- Division of Gastroenterology, Hepatology and Nutrition, Boston Children’s Hospital, Boston, MA
| | - Roshan Raza
- Division of Gastroenterology, Hepatology and Nutrition, Boston Children’s Hospital, Boston, MA
| | | | | | - Paul D. Mitchell
- Clinical Research Center, Boston Children’s Hospital, Boston, MA
| | - Maureen M Jonas
- Division of Gastroenterology, Hepatology and Nutrition, Boston Children’s Hospital, Boston, MA
| |
Collapse
|
62
|
Wang J, Li P, Jiang Z, Yang Q, Mi Y, Liu Y, Shi R, Zhou Y, Wang J, Lu W, Li S, Liu D. Diagnostic value of alcoholic liver disease (ALD)/nonalcoholic fatty liver disease (NAFLD) index combined with γ-glutamyl transferase in differentiating ALD and NAFLD. Korean J Intern Med 2016; 31:479-87. [PMID: 27025268 PMCID: PMC4855105 DOI: 10.3904/kjim.2015.253] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Revised: 08/24/2015] [Accepted: 08/25/2015] [Indexed: 01/15/2023] Open
Abstract
BACKGROUND/AIMS This study aimed to verify the reliability of the alcoholic liver disease (ALD)/nonalcoholic fatty liver disease (NAFLD) index (ANI) for distinguishing ALD in patients with hepatic steatosis from NAFLD, and to investigate whether ANI combined with γ-glutamyl transferase (GGT) would enhance the accuracy of diagnosis in China. METHODS A hundred thirty-nine cases of fatty liver disease (FLD) were divided into two groups of ALD and NAFLD. The ANI was calculated with an online calculator. All indicators and ANI values were analyzed using statistical methods. RESULTS ANI was significantly higher in patients with ALD than in those with NAFLD (7.11 ± 5.77 vs. -3.09 ± 3.89, p < 0.001). With a cut-off value of -0.22, the sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) of diagnosed ALD cases was 87.1%, 92.5%, and 0.934 (95% confidence interval [CI], 0.879 to 0.969), respectively. The corresponding values for aspartate aminotransferase (AST)/alanine transaminase (ALT), mean corpuscular volume (MCV), and GGT were 75.29%, 72.94%, and 0.826 (95% CI, 0.752 to 0.885); 94.34%, 83.02%, and 0.814 (95% CI, 0.739 to 0.875) and 80.23%, 79.25%, and 0.815 (95% CI, 0.740 to 0.876), respectively. ANI AUROC was significantly higher than the AST/ALT, MCV, or GGT AUROCs (all p < 0.001), moreover, ANI showed better diagnostic performance. The combination of ANI and GGT showed a better AUROC than ANI alone (0.976 vs. 0.934, p = 0.016). The difference in AUROCs between AST/ALT, MCV, and GGT was not statistically significant (all p > 0.05). CONCLUSIONS ANI can help distinguish ALD from NAFLD with high accuracy; when ANI was combined with GGT, its effectiveness improved further.
Collapse
Affiliation(s)
- Junling Wang
- Graduate School of Tianjin Medical University, Tianjin Second People’s Hospital, Tianjin, China
| | - Ping Li
- Department II of Chinese Integrative Medicine, Tianjin Second People’s Hospital, Tianjin Medical University, Tianjin, China
- Correspondence to Ping Li, M.D. Department II of Chinese Integrative Medicine, Tianjin Second People’s Hospital, Tianjin Medical University, 7 Sudi Road, Nankai District, Tianjin, China Tel: +86-13920265719 Fax: +86-22-27468232 E-mail:
| | - Zhilong Jiang
- Tianjin University of Traditional Chinese Medicine, Tianjin Second People’s Hospital, Tianjin, China
| | - Qiuhui Yang
- Graduate School of Tianjin Medical University, Tianjin Second People’s Hospital, Tianjin, China
| | - Yuqiang Mi
- Department II of Chinese Integrative Medicine, Tianjin Second People’s Hospital, Tianjin Medical University, Tianjin, China
| | - Yonggang Liu
- Department of Pathology, Tianjin Second People’s Hospital, Tianjin, China
| | - Ruifang Shi
- Department of Pathology, Tianjin Second People’s Hospital, Tianjin, China
| | - Yonghe Zhou
- Department of Radiology, Tianjin Second People’s Hospital, Tianjin, China
| | - Jinsheng Wang
- Department of Radiology, Tianjin Second People’s Hospital, Tianjin, China
| | - Wei Lu
- Department II of Chinese Integrative Medicine, Tianjin Second People’s Hospital, Tianjin Medical University, Tianjin, China
| | - Si Li
- Tianjin University of Traditional Chinese Medicine, Tianjin Second People’s Hospital, Tianjin, China
| | - Dan Liu
- Tianjin University of Traditional Chinese Medicine, Tianjin Second People’s Hospital, Tianjin, China
| |
Collapse
|
63
|
Song YJ, Chang X, Li XY, Zhang P, Tian ZB. Factors influencing controlled attenuation parameter measured by Fibrotouch in healthy individuals. Shijie Huaren Xiaohua Zazhi 2016; 24:1874-1879. [DOI: 10.11569/wcjd.v24.i12.1874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
AIM: To explore the factors influencing controlled attenuation parameter (CAP) obtained by FibroTouch in the general population.
METHODS: This study recruited 664 healthy individuals, and CAP measurement was conducted by Fibrotouch examination. Blood lipids, blood biochemical indexes, the classification results of fatty liver by ultrasound, gender, age and body mass index (BMI) were assessed. Multiple linear regression analysis was used for statistical analysis.
RESULTS: Multiple liner regression analysis showed that CAP value was significantly correlated with the classification results of fatty liver by ultrasound, BMI and alanine transaminase (ALT) (F = 228.89, P < 0.0001; standard regression coefficient of the classification results of fatty liver by ultrasound, β = 0.55, P < 0.0001; of BMI, β = 0.31, P < 0.0001; of ALT, β = 0.08, P = 0.0279), and the regression equation established after multiple linear regression analysis was CAP = 118.0044 + 17.2832 × the classification results of fatty liver by ultrasound + 3.3909 × BMI + 0.1919 × ALT.
CONCLUSION: CAP value might be affected by BMI, the classification results of fatty liver by ultrasound and serum ALT levels in the general population.
Collapse
|
64
|
Chang PE, Goh GBB, Ngu JH, Tan HK, Tan CK. Clinical applications, limitations and future role of transient elastography in the management of liver disease. World J Gastrointest Pharmacol Ther 2016; 7:91-106. [PMID: 26855815 PMCID: PMC4734958 DOI: 10.4292/wjgpt.v7.i1.91] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Revised: 09/05/2015] [Accepted: 10/27/2015] [Indexed: 02/06/2023] Open
Abstract
Transient elastography (TE) is a reliable tool for the non-invasive assessment of liver fibrosis in routine clinical practice. TE is currently approved for use in Europe, Asia and the United States. The widespread adoption of this technology is certain to increase the use of TE worldwide. Although TE has been well validated in chronic viral hepatitis, its clinical role in other liver diseases remains less clear. The advent of new treatment for chronic hepatitis C and emerging prevalence of non-alcoholic steatohepatitis raises new questions on the role of TE in current clinical practice. This review aims to examine the clinical applications, limitations and future role of TE in current clinical practice in light of the changing epidemiology of liver diseases and new clinical management paradigms. In current clinical practice, TE is the most accurate non-invasive method for diagnosis of liver cirrhosis. TE is useful to rule out fibrosis and cirrhosis but does not have sufficient accuracy to discern between various stages of fibrosis. The clinical role of TE has evolved from cross-sectional point-in-time assessment of fibrosis and cirrhosis to the more relevant role of prediction of vital clinical end-points. This provides clinicians with the ability to modify treatment strategies based on the information provided by TE. TE has evolved over the past decade to become an essential tool to assist the clinician in the management of chronic liver disease.
Collapse
|
65
|
Sasso M, Audière S, Kemgang A, Gaouar F, Corpechot C, Chazouillères O, Fournier C, Golsztejn O, Prince S, Menu Y, Sandrin L, Miette V. Liver Steatosis Assessed by Controlled Attenuation Parameter (CAP) Measured with the XL Probe of the FibroScan: A Pilot Study Assessing Diagnostic Accuracy. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:92-103. [PMID: 26386476 DOI: 10.1016/j.ultrasmedbio.2015.08.008] [Citation(s) in RCA: 106] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2015] [Revised: 07/09/2015] [Accepted: 08/11/2015] [Indexed: 06/05/2023]
Abstract
To assess liver steatosis, the controlled attenuation parameter (CAP; giving an estimate of ultrasound attenuation ∼3.5 MHz) is available with the M probe of the FibroScan. We report on the adaptation of the CAP for the FibroScan XL probe (center frequency 2.5 MHz) without modifying the range of values (100-400 dB/m). CAP validation was successfully performed on Field II simulations and on tissue-mimicking phantoms. In vivo performance was assessed in a cohort of 59 patients spanning the range of steatosis. In vivo reproducibility was good and similar with both probes. The area under receiver operative characteristic curve was equal to 0.83/0.84 and 0.92/0.91 for the M/XL probes to detect >2% and >16% liver fat, respectively, as assessed by magnetic resonance imaging. Patients can now be assessed simultaneously for steatosis and fibrosis using the FibroScan, regardless of their morphology.
Collapse
Affiliation(s)
| | | | - Astrid Kemgang
- Assistance Publique-Hôpitaux de Paris, Hôpital Saint-Antoine, Centre de Référence Maladies Rares des Maladies Inflammatoires des Voies Biliaires, et Service d'hépatologie, Centre de Recherche Saint-Antoin, Sorbonne Université, Paris, France
| | - Farid Gaouar
- Assistance Publique-Hôpitaux de Paris, Hôpital Saint-Antoine, Centre de Référence Maladies Rares des Maladies Inflammatoires des Voies Biliaires, et Service d'hépatologie, Centre de Recherche Saint-Antoin, Sorbonne Université, Paris, France
| | - Christophe Corpechot
- Assistance Publique-Hôpitaux de Paris, Hôpital Saint-Antoine, Centre de Référence Maladies Rares des Maladies Inflammatoires des Voies Biliaires, et Service d'hépatologie, Centre de Recherche Saint-Antoin, Sorbonne Université, Paris, France
| | - Olivier Chazouillères
- Assistance Publique-Hôpitaux de Paris, Hôpital Saint-Antoine, Centre de Référence Maladies Rares des Maladies Inflammatoires des Voies Biliaires, et Service d'hépatologie, Centre de Recherche Saint-Antoin, Sorbonne Université, Paris, France
| | | | | | - Stéphane Prince
- Department of Radiology, Hôpital Saint-Antoine, APHP, Paris, France
| | - Yves Menu
- Department of Radiology, Hôpital Saint-Antoine, APHP, Paris, France
| | | | | |
Collapse
|
66
|
Shen F, Zheng R, Shi J, Mi Y, Chen G, Hu X, Liu Y, Wang X, Pan Q, Chen G, Chen J, Xu L, Zhang R, Xu L, Fan J. Impact of skin capsular distance on the performance of controlled attenuation parameter in patients with chronic liver disease. Liver Int 2015; 35:2392-2400. [PMID: 25689614 PMCID: PMC5023997 DOI: 10.1111/liv.12809] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2014] [Accepted: 02/11/2015] [Indexed: 12/14/2022]
Abstract
BACKGROUND & AIMS Controlled attenuation parameter (CAP) is a non-invasive method for evaluating hepatic steatosis. However, larger skin capsular distance (SCD) can affect the accuracy. The aim of this study was to investigate the impact of SCD on the diagnostic performance of CAP and liver stiffness measurement (LSM). METHODS Of 101 patients with non-alcoholic fatty liver disease (NAFLD) and 280 patients with chronic hepatitis B (CHB) who underwent liver biopsy were prospectively recruited. CAP, LSM and SCD were performed using FibroScan with M probe. The areas under receiver operating characteristics curves (AUROCs) were calculated to determine the diagnostic efficacy. The optimal thresholds were defined by the maximum Youden index. RESULTS SCD (B 30.34, P < 0.001) and hepatic steatosis (B 23.04, P < 0.001) were independently associated with CAP by multivariate analysis. The AUROCs were slightly higher for SCD <25 mm compared to those for SCD ≥25 mm for steatosis ≥5% (0.88 vs. 0.81), >33% (0.90 vs. 0.85) and >66% (0.84 vs. 0.72). For SCD <25 mm, the optimal CAP cut-offs for differentiating steatosis ≥5%, >33% and >66% were 255.0 dB/m, 283.5 dB/m and 293.5 dB/m. However, cut-offs were elevated by approximately 60-70 dB/m for SCD ≥25 mm. When stratified by fibrosis grade, LSM was significantly affected by SCD ≥25 mm for advanced fibrosis (≥F3) in NAFLD, but not in CHB. CONCLUSION CAP is a promising tool for detecting and quantifying hepatic steatosis. SCD ≥25 mm may cause overestimation of steatosis. Similarly, SCD ≥25 mm affects the detection of advanced fibrosis by LSM in NAFLD patients.
Collapse
Affiliation(s)
- Feng Shen
- Department of GastroenterologyXinhua HospitalShanghai Jiaotong University School of MedicineShanghaiChina
| | - Rui‐Dan Zheng
- Research and Therapy Centre for Liver DiseaseZhengxing HospitalZhangzhouChina
| | - Jun‐Ping Shi
- Department of Liver DiseasesThe Affiliated Hospital of Hangzhou Normal UniversityHangzhouChina
| | - Yu‐Qiang Mi
- Research Institute of Liver DiseasesTianjin Second People's HospitalTianjinChina
| | - Guo‐Feng Chen
- Centre for Liver Fibrosis Treatment Unit302 Military HospitalBeijingChina
| | - Xiqi Hu
- Department of PathologyShanghai Medical College of Fudan UniversityShanghaiChina
| | - Yong‐Gang Liu
- Research Institute of Liver DiseasesTianjin Second People's HospitalTianjinChina
| | - Xiao‐Ying Wang
- Department of PathologyXinhua HospitalShanghai Jiaotong University School of MedicineShanghaiChina
| | - Qin Pan
- Department of GastroenterologyXinhua HospitalShanghai Jiaotong University School of MedicineShanghaiChina
| | - Guang‐Yu Chen
- Department of GastroenterologyXinhua HospitalShanghai Jiaotong University School of MedicineShanghaiChina
| | - Jian‐Neng Chen
- Research and Therapy Centre for Liver DiseaseZhengxing HospitalZhangzhouChina
| | - Liang Xu
- Research Institute of Liver DiseasesTianjin Second People's HospitalTianjinChina
| | - Rui‐Nan Zhang
- Department of GastroenterologyXinhua HospitalShanghai Jiaotong University School of MedicineShanghaiChina
| | - Lei‐Ming Xu
- Department of GastroenterologyXinhua HospitalShanghai Jiaotong University School of MedicineShanghaiChina
| | - Jian‐Gao Fan
- Department of GastroenterologyXinhua HospitalShanghai Jiaotong University School of MedicineShanghaiChina
| |
Collapse
|
67
|
Mi YQ, Shi QY, Xu L, Shi RF, Liu YG, Li P, Shen F, Lu W, Fan JG. Controlled attenuation parameter for noninvasive assessment of hepatic steatosis using Fibroscan®: validation in chronic hepatitis B. Dig Dis Sci 2015; 60:243-251. [PMID: 25194851 DOI: 10.1007/s10620-014-3341-x] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2014] [Accepted: 08/19/2014] [Indexed: 12/15/2022]
Abstract
BACKGROUND AND AIM The controlled attenuation parameter (CAP) using transient elastography (TE) was validated in chronic hepatitis C to evaluate hepatic steatosis; however, limited data are available on chronic hepatitis B (CHB). Therefore, we assessed the accuracy and the efficacy of CAP for the detection of steatosis in CHB. METHODS Consecutive CHB patients underwent liver biopsy and liver stiffness measurements (LSM) with simultaneous CAP determination using the M probe of the TE. The area under the receiver operating characteristics curve (AUROC) was used to evaluate the performance of CAP in diagnosing steatosis compared with biopsy. RESULTS A total of 340 patients were included: 60 % were male, the median age was 37 years; the body mass index (BMI) was ≥ 28 kg/m(2) for 14 % of the subjects; and the distribution of the steatosis grade was S0 58.2 %, S1 34.2 %, S2 5.0 % and S3 2.6 %. The median (range) of CAP was 218 (100-400) dB/m, and CAP correlated with the BMI (ρ = 3.622) and steatosis grade (ρ = 29.203) according to a multivariate analysis (both P < 0.001). CAP could detect the different grades of steatosis: ≥ S1 with AUROC of 0.81 at a cutoff of 224 dB/m, ≥ S2 with AUROC of 0.90 at a cutoff of 236 dB/m and ≥ S3 with AUROC of 0.97 at a cutoff of 285 dB/m. Furthermore, the LSM and fibrosis and activity grades on biopsy did not influence the CAP performance. CONCLUSIONS CAP presented excellent diagnostic performance for severe steatosis with high sensitivity and specificity in Chinese patients with CHB.
Collapse
Affiliation(s)
- Yu-Qiang Mi
- Department II of Chinese Integrative Medicine, Tianjin Second People's Hospital, Tianjin Medical University, Tianjin, China,
| | | | | | | | | | | | | | | | | |
Collapse
|
68
|
Mueller S, Seitz HK, Rausch V. Non-invasive diagnosis of alcoholic liver disease. World J Gastroenterol 2014; 20:14626-41. [PMID: 25356026 PMCID: PMC4209529 DOI: 10.3748/wjg.v20.i40.14626] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2014] [Revised: 04/30/2014] [Accepted: 07/22/2014] [Indexed: 02/06/2023] Open
Abstract
Alcoholic liver disease (ALD) is the most common liver disease in the Western world. For many reasons, it is underestimated and underdiagnosed. An early diagnosis is absolutely essential since it (1) helps to identify patients at genetic risk for ALD; (2) can trigger efficient abstinence namely in non-addicted patients; and (3) initiate screening programs to prevent life-threatening complications such as bleeding from varices, spontaneous bacterial peritonitis or hepatocellular cancer. The two major end points of ALD are alcoholic liver cirrhosis and the rare and clinically-defined alcoholic hepatitis (AH). The prediction and early diagnosis of both entities is still insufficiently solved and usually relies on a combination of laboratory, clinical and imaging findings. It is not widely conceived that conventional screening tools for ALD such as ultrasound imaging or routine laboratory testing can easily overlook ca. 40% of manifest alcoholic liver cirrhosis. Non-invasive methods such as transient elastography (Fibroscan), acoustic radiation force impulse imaging or shear wave elastography have significantly improved the early diagnosis of alcoholic cirrhosis. Present algorithms allow either the exclusion or the exact definition of advanced fibrosis stages in ca. 95% of patients. The correct interpretation of liver stiffness requires a timely abdominal ultrasound and actual transaminase levels. Other non-invasive methods such as controlled attenuation parameter, serum levels of M30 or M65, susceptometry or breath tests are under current evaluation to assess the degree of steatosis, apoptosis and iron overload in these patients. Liver biopsy still remains an important option to rule out comorbidities and to confirm the prognosis namely for patients with AH.
Collapse
|
69
|
Ferraioli G, Tinelli C, Lissandrin R, Zicchetti M, Rondanelli M, Perani G, Bernuzzi S, Salvaneschi L, Filice C. Interobserver reproducibility of the controlled attenuation parameter (CAP) for quantifying liver steatosis. Hepatol Int 2014; 8:576-581. [PMID: 26202762 DOI: 10.1007/s12072-014-9573-1] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2014] [Accepted: 08/15/2014] [Indexed: 12/16/2022]
Abstract
PURPOSE This study was conducted to prospectively investigate the interobserver reproducibility of controlled attenuation parameter (CAP) measurements and the relationship among the CAP and body mass index (BMI), gender and age. METHODS Consecutive subjects were studied using the M+ probe of the FibroScan device (Echosens, Paris, France). Measurements were performed by two raters (rater1 and rater2). Interobserver agreement was assessed by using the concordance correlation coefficient (CCC). The Pearson r coefficient was used to test correlation between two study variables, and linear regression was used for the multivariate model. RESULTS Three hundred fifty-one subjects (227 males and 124 females) were prospectively studied. The CCC was 0.82 (95 % CI 0.78-0.85) overall, 0.80 (95 % CI 0.75-0.85) for BMI <25 kg/m(2), 0.76 (95 % CI 0.69-0.84) for BMI 25-29 kg/m(2) and 0.65 (95 % CI 0.41-0.88) for BMI ≥30 kg/m(2). The CCC was 0.44 (95 % CI 0.31-0.56) for CAP values ≤240 dB/m and 0.72 (95 % CI 0.65-0.79) for CAP values >240 dB/m. In univariate analysis, age and BMI by gender were correlated with the CAP. Multiple regression analysis confirmed the relationship of the CAP with age and BMI, but not with gender. CONCLUSIONS The results of this study show that the interreader agreement in CAP measurement is good. In healthy volunteers, the CAP is strongly correlated with age and BMI.
Collapse
Affiliation(s)
- Giovanna Ferraioli
- Ultrasound Unit, Department of Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Via Taramelli 5, 27100, Pavia, Italy.
| | - Carmine Tinelli
- Clinical Epidemiology and Biometric Unit, Fondazione IRCCS Policlinico San Matteo, Viale Camillo Golgi 19, 27100, Pavia, Italy
| | - Raffaella Lissandrin
- Ultrasound Unit, Department of Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Via Taramelli 5, 27100, Pavia, Italy
| | - Mabel Zicchetti
- Ultrasound Unit, Department of Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Via Taramelli 5, 27100, Pavia, Italy
| | - Mariangela Rondanelli
- Department of Applied Health Sciences, Istituto di Cura "Santa Margherita", University of Pavia, Via Emilia 12, 27100, Pavia, Italy
| | - Guido Perani
- Department of Internal Medicine, Fondazione IRCCS Policlinico San Matteo, Viale Camillo Golgi 19, 27100, Pavia, Italy
| | - Stefano Bernuzzi
- Department of "Medicina Diagnostica e dei Servizi", Fondazione IRCCS Policlinico San Matteo, Viale Camillo Golgi 19, 27100, Pavia, Italy
| | - Laura Salvaneschi
- Department of "Medicina Diagnostica e dei Servizi", Fondazione IRCCS Policlinico San Matteo, Viale Camillo Golgi 19, 27100, Pavia, Italy
| | - Carlo Filice
- Ultrasound Unit, Department of Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Via Taramelli 5, 27100, Pavia, Italy
| |
Collapse
|
70
|
Ahn JM, Paik YH, Kim SH, Lee JH, Cho JY, Sohn W, Gwak GY, Choi MS, Lee JH, Koh KC, Paik SW, Yoo BC. Relationship of liver stiffness and controlled attenuation parameter measured by transient elastography with diabetes mellitus in patients with chronic liver disease. J Korean Med Sci 2014; 29:1113-9. [PMID: 25120322 PMCID: PMC4129204 DOI: 10.3346/jkms.2014.29.8.1113] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2014] [Accepted: 05/07/2014] [Indexed: 12/17/2022] Open
Abstract
High prevalence of diabetes mellitus in patients with liver cirrhosis has been reported in many studies. The aim of our study was to evaluate the relationship of hepatic fibrosis and steatosis assessed by transient elastography with diabetes in patients with chronic liver disease. The study population consisted of 979 chronic liver disease patients. Liver fibrosis and steatosis were assessed by liver stiffness measurement (LSM) and controlled attenuation parameter (CAP) on transient elastography. Diabetes was diagnosed in 165 (16.9%) of 979 patients. The prevalence of diabetes had significant difference among the etiologies of chronic liver disease. Higher degrees of liver fibrosis and steatosis, assessed by LSM and CAP score, showed higher prevalence of diabetes (F0/1 [14%], F2/3 [18%], F4 [31%], P<0.001; S0/1 [15%], S2 [17%], S3 [26%], P=0.021). Multivariate analysis showed that the independent predictive risk factors for diabetes were hypertension (OR, 1.98; P=0.001), LSM F4 (OR, 1.86; P=0.010), male gender (OR, 1.60; P=0.027), and age>50 yr (OR, 1.52; P=0.046). The degree of hepatic fibrosis but not steatosis assessed by transient elastography has significant relationship with the prevalence of diabetes in patients with chronic liver disease.
Collapse
Affiliation(s)
- Jem Ma Ahn
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Yong-Han Paik
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - So Hyun Kim
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Jun Hee Lee
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Ju Yeon Cho
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Won Sohn
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Geum-Youn Gwak
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Moon Seok Choi
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Joon Hyeok Lee
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Kwang Cheol Koh
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Seung Woon Paik
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Byung Chul Yoo
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|
71
|
Chan WK, Nik Mustapha NR, Mahadeva S. Controlled attenuation parameter for the detection and quantification of hepatic steatosis in nonalcoholic fatty liver disease. J Gastroenterol Hepatol 2014; 29:1470-6. [PMID: 24548002 DOI: 10.1111/jgh.12557] [Citation(s) in RCA: 135] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/23/2014] [Indexed: 12/12/2022]
Abstract
BACKGROUND AND AIM Controlled attenuation parameter (CAP) has been suggested as a noninvasive method for detection and quantification of hepatic steatosis. We aim to study the diagnostic performance of CAP in nonalcoholic fatty liver disease (NAFLD) patients. METHODS Transient elastography was performed in consecutive NAFLD patients undergoing liver biopsy and non-NAFLD controls. The accuracy of CAP for the detection and quantification of hepatic steatosis was assessed based on histological findings according to the Nonalcoholic Steatohepatitis Clinical Research Network Scoring System. RESULTS Data for 101 NAFLD patients (mean age 50.3 ± 11.3 years old, 51.5% male) and 60 non-NAFLD controls were analyzed. CAP was associated with steatosis grade (odds ratio [OR] = 29.16, P < 0.001), body mass index (BMI; OR = 4.34, P < 0.001) and serum triglyceride (OR = 13.59, P = 0.037) on multivariate analysis. The median CAP for steatosis grades S0, S1, S2, and S3 were 184 dB/m, 305 dB/m, 320 dB/m, and 324 dB/m, respectively. The areas under receiver operating characteristics curves (AUROC) for estimation of steatosis grades ≥ S1, S2, and S3 were 0.97, 0.86, and 0.75, respectively. The optimal CAP cutoffs for estimation of steatosis grades ≥ S1, S2, and S3 were 263 dB/m, 281 dB/m, and 283 dB/m, respectively. Among non-obese patients, the AUROC for estimation of steatosis grades ≥ S1 and S2 were 0.99 and 0.99, respectively. Among obese patients, the AUROC for estimation of steatosis grades ≥ S1, S2, and S3 were 0.92, 0.64, and 0.58, respectively. CONCLUSIONS CAP is excellent for the detection of significant hepatic steatosis. However, its accuracy is impaired by an increased BMI, and it is less accurate to distinguish between the different grades of hepatic steatosis.
Collapse
Affiliation(s)
- Wah-Kheong Chan
- Gastroenterology and Hepatology Unit, Gastrointestinal Endoscopy Unit, Department of Medicine, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
| | | | | |
Collapse
|
72
|
Carvalhana S, Leitão J, Alves AC, Bourbon M, Cortez-Pinto H. How good is controlled attenuation parameter and fatty liver index for assessing liver steatosis in general population: correlation with ultrasound. Liver Int 2014; 34:e111-7. [PMID: 24034415 DOI: 10.1111/liv.12305] [Citation(s) in RCA: 61] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2013] [Accepted: 08/05/2013] [Indexed: 12/18/2022]
Abstract
BACKGROUND & AIMS Liver steatosis measurement by controlled attenuation parameter (CAP) is a non-invasive method for diagnosing steatosis, based on transient elastography. Its usefulness as screening procedure for hepatic steatosis in general population has not been previously evaluated. The aim of this study was to evaluate the diagnostic accuracy of CAP and fatty liver index (FLI) for detection and quantification of steatosis in general population. METHODS Recruitment was done from a prospective epidemiological study of the general adult population. Steatosis was evaluated using CAP, FLI and ultrasound (US). Steatosis scored according to Hamaguchi's US scoring, from 0 (S0) to 6 (S6) points. Hepatic steatosis defined by score ≥2 (S≥2) and moderate/severe steatosis by score ≥4 (S≥4). Performance of CAP and FLI for diagnosing steatosis compared with US was assessed using areas under receiver operating characteristic curves (AUROC). RESULTS From 219 consecutive individuals studied, 13 (5.9%) excluded because of failure/unreliable liver stiffness measurements. Steatosis prevalence: S≥2 38.4% and S≥4 12.1%. CAP significantly correlated with steatosis (ρ = 0.73, P < 0.0001), steatosis score (ρ = 0.76; P < 0.0001), FLI (ρ = 0.69), waist circumference (ρ = 0.62), body mass index (ρ = 0.55), triglyceride (ρ = 0.49), HOMA-IR (ρ = 0.26), alcohol consumption (ρ = 0.24) and cholesterol (ρ = 0.19), not with liver stiffness measurements. Using CAP and FLI, AUROC's were 0.94 (95% CI 0.91-0.97, P < 0.001) and 0.91 for S≥2; 0.95 (95% CI 0.90-0.99, P < 0.001) and 0.93 for S≥4 respectively. Optimal cut-off value of CAP and FLI were 243 dB/m and 48 for S≥2; 303.5 dB/m and 62 for S≥4 respectively. CONCLUSION Controlled attenuation parameter and FLI seem promising tools for screening and steatosis quantification in the general population. Larger studies are needed for validation.
Collapse
Affiliation(s)
- Sofia Carvalhana
- Departamento de Gastrenterologia, Unidade de Nutrição e Metabolismo, Hospital Santa Maria, CHLN, Faculdade de Medicina de Lisboa, IMM, Lisbon, Portugal
| | | | | | | | | |
Collapse
|
73
|
Jung KS, Kim BK, Kim SU, Chon YE, Cheon KH, Kim SB, Lee SH, Ahn SS, Park JY, Kim DY, Ahn SH, Park YN, Han KH. Factors affecting the accuracy of controlled attenuation parameter (CAP) in assessing hepatic steatosis in patients with chronic liver disease. PLoS One 2014; 9:e98689. [PMID: 24901649 PMCID: PMC4046989 DOI: 10.1371/journal.pone.0098689] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2013] [Accepted: 05/07/2014] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND & AIMS Controlled attenuation parameter (CAP) can measure hepatic steatosis. However, factors affecting its accuracy have not been described yet. This study investigated predictors of discordance between liver biopsy (LB) and CAP. METHODS A total of 161 consecutive patients with chronic liver disease who underwent LB and CAP were enrolled prospectively. Histological steatosis was graded as S0 (<5%), S1 (5-33%), S2 (34-66%), and S3 (>66% of hepatocytes). Cutoff CAP values were calculated from our cohort (250, 301, and 325 dB/m for ≥ S1, ≥ S2, and S3). Discordance was defined as a discrepancy of at least two steatosis stages between LB and CAP. RESULTS The median age (102 males and 59 females) was 49 years. Repartition of histological steatosis was as follows; S0 26.1% (n = 42), S1 49.7% (n = 80), S2 20.5% (n = 33), and S3 3.7% (n = 6). In multivariate linear regression analysis, CAP value was independently associated with steatosis grade along with body mass index (BMI) and interquartile range/median of CAP value (IQR/MCAP) (all P<0.05). Discordance was identified in 13 (8.1%) patients. In multivariate analysis, histological S3 (odd ratio [OR], 9.573; 95% confidence interval [CI], 1.207-75.931; P = 0.033) and CAP value (OR, 1.020; 95% CI, 1.006-1.034; P = 0.006) were significantly associated with discordance, when adjusting for BMI, IQR/MCAP, and necroinflammation, reflected by histological activity or ALT level. CONCLUSIONS Patients with high grade steatosis or high CAP values have a higher risk of discordance between LB and CAP. Further studies are needed to improve the accuracy of CAP interpretation, especially in patients with higher CAP values.
Collapse
Affiliation(s)
- Kyu Sik Jung
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Beom Kyung Kim
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
- Institute of Gastroenterology, Yonsei University College of Medicine, Seoul, Korea
- Liver Cirrhosis Clinical Research Center, Seoul, Korea
| | - Seung Up Kim
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
- Institute of Gastroenterology, Yonsei University College of Medicine, Seoul, Korea
- Liver Cirrhosis Clinical Research Center, Seoul, Korea
| | - Young Eun Chon
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Kyung Hyun Cheon
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Sung Bae Kim
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Sang Hoon Lee
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Sung Soo Ahn
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Jun Yong Park
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
- Institute of Gastroenterology, Yonsei University College of Medicine, Seoul, Korea
- Liver Cirrhosis Clinical Research Center, Seoul, Korea
| | - Do Young Kim
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
- Institute of Gastroenterology, Yonsei University College of Medicine, Seoul, Korea
- Liver Cirrhosis Clinical Research Center, Seoul, Korea
| | - Sang Hoon Ahn
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
- Institute of Gastroenterology, Yonsei University College of Medicine, Seoul, Korea
- Liver Cirrhosis Clinical Research Center, Seoul, Korea
- Brain Korea 21 Project of Medical Science, Seoul, Korea
| | - Young Nyun Park
- Department of Pathology, Yonsei University College of Medicine, Seoul, Korea
| | - Kwang-Hyub Han
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
- Institute of Gastroenterology, Yonsei University College of Medicine, Seoul, Korea
- Liver Cirrhosis Clinical Research Center, Seoul, Korea
- Brain Korea 21 Project of Medical Science, Seoul, Korea
| |
Collapse
|
74
|
Shi KQ, Tang JZ, Zhu XL, Ying L, Li DW, Gao J, Fang YX, Li GL, Song YJ, Deng ZJ, Wu JM, Tang KF. Controlled attenuation parameter for the detection of steatosis severity in chronic liver disease: a meta-analysis of diagnostic accuracy. J Gastroenterol Hepatol 2014; 29:1149-58. [PMID: 24476011 DOI: 10.1111/jgh.12519] [Citation(s) in RCA: 108] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/12/2014] [Indexed: 12/12/2022]
Abstract
BACKGROUND AND AIM Controlled attenuation parameter (CAP) is a novel ultrasound-based elastography method for detection of steatosis severity. This meta-analysis aimed to assess the performance of CAP. METHODS PubMed, the Cochrane Library, and the Web of Knowledge were searched to find studies, published in English, relating to accuracy evaluations of CAP for detecting stage 1 (S1), stage 2 (S2), or stage 3 (S3) hepatic steatosis which was diagnosed by liver biopsy. Sensitivities, specificities, and hierarchical summary receiver operating characteristic (HSROC) curves were used to examine CAP performance. The clinical utility of CAP was also evaluated. RESULTS Nine studies, with 11 cohorts were analyzed. The summary sensitivities and specificities values were 0.78 (95% confidence interval [CI], 0.69-0.84) and 0.79 (95% CI, 0.68-0.86) for ≥ S1, 0.85 (95% CI, 0.74-0.92) and 0.79 (95% CI, 0.71-0.85) for ≥ S2, and 0.83 (95% CI, 0.76-0.89) and 0.79 (95% CI, 0.68-0.87) for ≥ S3. The HSROCs were 0.85 (95% CI, 0.81-88) for ≥ S1, 0.88 (95% CI, 0.85-0.91) for ≥ S2, and 0.87 (95% CI, 0.84-0.90) for ≥ S3. Following a "positive" measurement (over the threshold value) for ≥ S1, ≥ S2, and ≥ S3, the corresponding post-test probabilities for the presence of steatosis (pretest probability was 50%) were 78%, 80% and 80%, respectively; if the values were below these thresholds ("negative" results), the post-test probabilities were 22%, 16%, and 17%, respectively. CONCLUSIONS CAP has good sensitivity and specificity for detecting hepatic steatosis; however, based on a meta-analysis, CAP was limited in their accuracy of steatosis, which precluded widespread use in clinical practice.
Collapse
Affiliation(s)
- Ke-Qing Shi
- Department of Infection and Liver Diseases, Institution of Hepatology, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
75
|
Gerstenmaier JF, Gibson RN. Ultrasound in chronic liver disease. Insights Imaging 2014; 5:441-55. [PMID: 24859758 PMCID: PMC4141343 DOI: 10.1007/s13244-014-0336-2] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2014] [Revised: 04/16/2014] [Accepted: 04/17/2014] [Indexed: 12/17/2022] Open
Abstract
Background With the high prevalence of diffuse liver disease there is a strong clinical need for noninvasive detection and grading of fibrosis and steatosis as well as detection of complications. Methods B-mode ultrasound supplemented by portal system Doppler and contrast-enhanced ultrasound are the principal techniques in the assessment of liver parenchyma and portal venous hypertension and in hepatocellular carcinoma surveillance. Results Fibrosis can be detected and staged with reasonable accuracy using Transient Elastography and Acoustic Radiation Force Imaging. Newer elastography techniques are emerging that are undergoing validation and may further improve accuracy. Ultrasound grading of hepatic steatosis currently is predominantly qualitative. Conclusion A summary of methods including B-mode, Doppler, contrast-enhanced ultrasound and various elastography techniques, and their current performance in assessing the liver, is provided. Teaching Points • Diffuse liver disease is becoming more prevalent and there is a strong clinical need for noninvasive detection. • Portal hypertension can be best diagnosed by demonstrating portosystemic collateral venous flow. • B-mode US is the principal US technique supplemented by portal system Doppler. • B-mode US is relied upon in HCC surveillance, and CEUS is useful in the evaluation of possible HCC. • Fibrosis can be detected and staged with reasonable accuracy using TE and ARFI. • US detection of steatosis is currently reasonably accurate but grading of severity is of limited accuracy.
Collapse
Affiliation(s)
- J F Gerstenmaier
- Department of Radiology, (RNG also University of Melbourne) The Royal Melbourne Hospital, Grattan Street, Parkville, VIC, 3050, Australia,
| | | |
Collapse
|
76
|
Yilmaz Y, Yesil A, Gerin F, Ergelen R, Akin H, Celikel ÇA, Imeryuz N. Detection of hepatic steatosis using the controlled attenuation parameter: a comparative study with liver biopsy. Scand J Gastroenterol 2014; 49:611-6. [PMID: 24611771 DOI: 10.3109/00365521.2014.881548] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVE Measurements of controlled attenuation parameter (CAP) with transient elastography (FibroScan®; EcoSens SA, Paris, France) may provide an accurate noninvasive assessment of hepatic steatosis. Herein, we prospectively determined the accuracy of liver fat quantification with CAP values in patients with chronic liver diseases and compare the results with those of histological assessment of steatosis as reference standard. MATERIALS AND METHODS We enrolled 50 Turkish patients with various forms of chronic liver diseases. All patients underwent both CAP assessment and ultrasonography-guided liver biopsy. RESULTS On liver biopsy, 16 (32%) patients had S0, 12 (24%) had S1, 9 (18%) had S2, and 13 (26%) had S3. The CAP values increased significantly (p<0.001) for each steatosis stage on liver biopsy: S0, 222 dB/m; S1, 250 dB/m; S2, 270 dB/m; and S3, 318 dB/m. A cutoff value of 257 dB/m could distinguish significant steatosis (S2-S3) from S0 (Sn 89%, Sp 83%, positive likelihood ratio 5.33, negative likelihood ratio 0.13, AUROC=0.93). Multivariable analysis indicated that neither liver fibrosis (p=0.58) nor disease etiology (p=0.96) had a significant impact on the association between CAP and the stage of steatosis. CONCLUSION The determination of CAP using transient elastography can represent an important step forward toward the goal of an "imaging liver biopsy".
Collapse
Affiliation(s)
- Yusuf Yilmaz
- Department of Gastroenterology, Marmara University, School of Medicine , Istanbul , Turkey
| | | | | | | | | | | | | |
Collapse
|
77
|
Shen F, Zheng RD, Mi YQ, Wang XY, Pan Q, Chen GY, Cao HX, Chen ML, Xu L, Chen JN, Cao Y, Zhang RN, Xu LM, Fan JG. Controlled attenuation parameter for non-invasive assessment of hepatic steatosis in Chinese patients. World J Gastroenterol 2014; 20:4702-4711. [PMID: 24782622 PMCID: PMC4000506 DOI: 10.3748/wjg.v20.i16.4702] [Citation(s) in RCA: 73] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2013] [Revised: 12/25/2013] [Accepted: 02/26/2014] [Indexed: 02/06/2023] Open
Abstract
AIM To evaluate the performance of a novel non-invasive controlled attenuation parameter (CAP) to assess liver steatosis. METHODS This was a multi-center prospective cohort study. Consecutive patients (aged ≥ 18 years) who had undergone percutaneous liver biopsy and CAP measurement were recruited from three Chinese liver centers. Steatosis was categorized as S0: < 5%; S1: 5%-33%; S2: 34%-66%; or S3: ≥ 67%, according to the nonalcoholic fatty liver disease (NAFLD) activity score. The FibroScan(®) 502 equipped with the M probe (Echosens, Paris, France) was used to capture both CAP and liver stiffness measurement values simultaneously. Receiver operating characteristic curves were plotted, and the areas under the curves were calculated to determine the diagnostic efficacy. The accuracy of the CAP values at the optimal thresholds was defined by maximizing the sum of sensitivity and specificity (maximum Youden index). RESULTS A total of 152 patients were recruited, including 52 (34.2%) patients with NAFLD and 100 (65.8%) with chronic hepatitis B (CHB) virus infection. After adjustment, the steatosis grade (OR = 37.12; 95%CI: 21.63-52.60, P < 0.001) and body mass index (BMI, OR = 6.20; 95%CI: 2.92-9.48, P < 0.001) were found independently associated with CAP by multivariate linear regression analysis. CAP was not influenced by inflammation, fibrosis or aetiology. The median CAP values and interquartile ranges among patients with S0, S1, S2 and S3 steatosis were 211 (181-240) dB/m, 270 (253-305) dB/m, 330 (302-360) dB/m, and 346 (313-363) dB/m, respectively. The cut-offs for the CAP values in all patients with steatosis ≥ 5%, ≥ 34% and ≥ 67% were 253 dB/m, 285 dB/m and 310 dB/m, respectively. The areas under the curves were 0.92, 0.92 and 0.88 for steatosis ≥ 5%, ≥ 34% and ≥ 67%, respectively. No significant differences were found in the CAP values between the NAFLD group and the CHB group in each steatosis grade. CONCLUSION CAP appears to be a promising tool for the non-invasive detection and quantification of hepatic steatosis, but is limited by BMI.
Collapse
|
78
|
Karlas T, Petroff D, Garnov N, Böhm S, Tenckhoff H, Wittekind C, Wiese M, Schiefke I, Linder N, Schaudinn A, Busse H, Kahn T, Mössner J, Berg T, Tröltzsch M, Keim V, Wiegand J. Non-invasive assessment of hepatic steatosis in patients with NAFLD using controlled attenuation parameter and 1H-MR spectroscopy. PLoS One 2014; 9:e91987. [PMID: 24637477 PMCID: PMC3956815 DOI: 10.1371/journal.pone.0091987] [Citation(s) in RCA: 116] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2013] [Accepted: 02/16/2014] [Indexed: 02/06/2023] Open
Abstract
Introduction Non-invasive assessment of steatosis and fibrosis is of growing relevance in non-alcoholic fatty liver disease (NAFLD). 1H-Magnetic resonance spectroscopy (1H-MRS) and the ultrasound-based controlled attenuation parameter (CAP) correlate with biopsy proven steatosis, but have not been correlated with each other so far. We therefore performed a head-to-head comparison between both methods. Methods Fifty patients with biopsy-proven NAFLD and 15 healthy volunteers were evaluated with 1H-MRS and transient elastography (TE) including CAP. Steatosis was defined according to the percentage of affected hepatocytes: S1 5-33%, S2 34–66%, S3 ≥67%. Results Steatosis grade in patients with NAFLD was S1 36%, S2 40% and S3 24%. CAP and 1H-MRS significantly correlated with histopathology and showed comparable accuracy for the detection of hepatic steatosis: areas under the receiver-operating characteristics curves were 0.93 vs. 0.88 for steatosis ≥S1 and 0.94 vs. 0.88 for ≥S2, respectively. Boot-strapping analysis revealed a CAP cut-off of 300 dB/m for detection of S2-3 steatosis, while retaining the lower cut-off of 215 dB/m for the definition of healthy individuals. Direct comparison between CAP and 1H-MRS revealed only modest correlation (total cohort: r = 0.63 [0.44, 0.76]; NAFLD cases: r = 0.56 [0.32, 0.74]). For detection of F2–4 fibrosis TE had sensitivity and specificity of 100% and 98.1% at a cut-off value of 8.85 kPa. Conclusion Our data suggest a comparable diagnostic value of CAP and 1H-MRS for hepatic steatosis quantification. Combined with the simultaneous TE fibrosis assessment, CAP represents an efficient method for non-invasive characterization of NAFLD. Limited correlation between CAP and 1H-MRS may be explained by different technical aspects, anthropometry, and presence of advanced liver fibrosis.
Collapse
Affiliation(s)
- Thomas Karlas
- IFB AdiposityDiseases, Leipzig University Medical Center, Leipzig, Germany; Department of Medicine, Neurology and Dermatology, Division of Gastroenterology and Rheumatology, University Hospital Leipzig, Leipzig, Germany
| | - David Petroff
- IFB AdiposityDiseases, Leipzig University Medical Center, Leipzig, Germany; Clinical Trial Center, University of Leipzig, Leipzig, Germany
| | - Nikita Garnov
- IFB AdiposityDiseases, Leipzig University Medical Center, Leipzig, Germany; Department of Diagnostics and Interventional Radiology, University Hospital Leipzig, Leipzig, Germany
| | - Stephan Böhm
- Department of Medicine, Neurology and Dermatology, Division of Gastroenterology and Rheumatology, Section of Hepatology, University Hospital Leipzig, Leipzig, Germany
| | - Hannelore Tenckhoff
- Department of Medicine, Neurology and Dermatology, Division of Gastroenterology and Rheumatology, Section of Hepatology, University Hospital Leipzig, Leipzig, Germany
| | | | - Manfred Wiese
- Department of Medicine, Neurology and Dermatology, Division of Gastroenterology and Rheumatology, Section of Hepatology, University Hospital Leipzig, Leipzig, Germany
| | - Ingolf Schiefke
- Clinic for Gastroenterology and Hepatology, Klinikum St. Georg, Leipzig, Germany
| | - Nicolas Linder
- IFB AdiposityDiseases, Leipzig University Medical Center, Leipzig, Germany; Department of Diagnostics and Interventional Radiology, University Hospital Leipzig, Leipzig, Germany
| | - Alexander Schaudinn
- IFB AdiposityDiseases, Leipzig University Medical Center, Leipzig, Germany; Department of Diagnostics and Interventional Radiology, University Hospital Leipzig, Leipzig, Germany
| | - Harald Busse
- Department of Diagnostics and Interventional Radiology, University Hospital Leipzig, Leipzig, Germany
| | - Thomas Kahn
- Department of Diagnostics and Interventional Radiology, University Hospital Leipzig, Leipzig, Germany
| | - Joachim Mössner
- Department of Medicine, Neurology and Dermatology, Division of Gastroenterology and Rheumatology, University Hospital Leipzig, Leipzig, Germany
| | - Thomas Berg
- Department of Medicine, Neurology and Dermatology, Division of Gastroenterology and Rheumatology, Section of Hepatology, University Hospital Leipzig, Leipzig, Germany
| | - Michael Tröltzsch
- Department of Medicine, Neurology and Dermatology, Division of Gastroenterology and Rheumatology, University Hospital Leipzig, Leipzig, Germany
| | - Volker Keim
- Department of Medicine, Neurology and Dermatology, Division of Gastroenterology and Rheumatology, University Hospital Leipzig, Leipzig, Germany
| | - Johannes Wiegand
- IFB AdiposityDiseases, Leipzig University Medical Center, Leipzig, Germany; Department of Medicine, Neurology and Dermatology, Division of Gastroenterology and Rheumatology, University Hospital Leipzig, Leipzig, Germany; Department of Medicine, Neurology and Dermatology, Division of Gastroenterology and Rheumatology, Section of Hepatology, University Hospital Leipzig, Leipzig, Germany
| |
Collapse
|