1
|
Zhou Z, Zhang D, Ning X, Jin L, Lin Y, Liang C, Wen X, Huang T, Zhou J, Zhang Y. An antibacterial, antioxidant and hemostatic hydrogel accelerates infectious wound healing. J Nanobiotechnology 2025; 23:49. [PMID: 39871272 PMCID: PMC11773726 DOI: 10.1186/s12951-025-03148-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2024] [Accepted: 01/22/2025] [Indexed: 01/29/2025] Open
Abstract
Hydrogel drug-delivery system that can effectively load antibacterial drugs, realize the in-situ drug release in the microenvironment of wound infection to promote wound healing. In this study, a multifunctional hydrogel drug delivery system (HA@TA-Okra) was constructed through the integration of hyaluronic acid methacrylate (HAMA) matrix with tannic acid (TA) and okra extract. The composition and structural characteristics of HA@TA-Okra system and its unique advantages in the treatment of diverse wounds were systematically evaluated. TA, due to its unique chemical structure, is able to anchor within the HAMA network through interactions and cross-linking, conferring exceptional mechanical strength and stability to the hydrogel. Both TA and okra extract possess antioxidant and antibacterial properties, and when they two acts synergistically they can effectively scavenge free radicals, enhance antibacterial action, diminishing the risk of wound infection. In vitro experiments revealed that HA@TA-Okra system has superior properties, such as rapid gel response, remarkable swelling regulation, and potent antioxidant ability. Furthermore, the HA@TA-Okra system significantly outperformed conventional dressings in terms of hemostatic performance in a rat hemorrhage model. We further evaluated the repair role of HA@TA-Okra system in vivo by establishing an animal model of full-thickness skin defects and a model of infected total skin defects. The results confirmed its positive effects in fighting bacterial infection, reducing inflammation and promoting wound healing. In summary, the HA@TA-Okra system exhibits comprehensive properties such as antibacterial, antioxidant and hemostatic properties, which has a potential application in the field of tissue repair medicine.
Collapse
Affiliation(s)
- Ziyi Zhou
- Department of Plastic and Cosmetic Surgery, Xinqiao Hospital, Army Medical University, Chongqing, 400037, China
| | - Dengjun Zhang
- Department of Plastic and Cosmetic Surgery, Xinqiao Hospital, Army Medical University, Chongqing, 400037, China
| | - Xuchao Ning
- Department of Plastic Surgery, Cheeloo College of Medicine, Qilu Hospital of Shandong University (Qingdao), Qingdao, 266035, China
| | - Linbo Jin
- Department of Plastic and Cosmetic Surgery, Xinqiao Hospital, Army Medical University, Chongqing, 400037, China
| | - Yijing Lin
- Department of Plastic and Cosmetic Surgery, Xinqiao Hospital, Army Medical University, Chongqing, 400037, China
| | - Chen Liang
- Department of Plastic and Cosmetic Surgery, Xinqiao Hospital, Army Medical University, Chongqing, 400037, China
| | - Xin Wen
- Department of Plastic and Cosmetic Surgery, Xinqiao Hospital, Army Medical University, Chongqing, 400037, China
| | - Tianhao Huang
- Department of Plastic and Cosmetic Surgery, Xinqiao Hospital, Army Medical University, Chongqing, 400037, China
| | - Junli Zhou
- Department of Burn and Plastic surgery, The Tenth Affiliated Hospital of Southern Medical University (Dongguan People's Hospital), Dongguan, China.
| | - Yiming Zhang
- Department of Plastic and Cosmetic Surgery, Xinqiao Hospital, Army Medical University, Chongqing, 400037, China.
| |
Collapse
|
2
|
Tang S, Feng K, Yang R, Cheng Y, Chen M, Zhang H, Shi N, Wei Z, Ren H, Ma Y. Multifunctional Adhesive Hydrogels: From Design to Biomedical Applications. Adv Healthc Mater 2025; 14:e2403734. [PMID: 39604246 DOI: 10.1002/adhm.202403734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2024] [Revised: 11/04/2024] [Indexed: 11/29/2024]
Abstract
Adhesive hydrogels characterized by structural properties similar to the extracellular matrix, excellent biocompatibility, controlled degradation, and tunable mechanical properties have demonstrated significant potential in biomedical applications, including tissue engineering, biosensors, and drug delivery systems. These hydrogels exhibit remarkable adhesion to target substrates and can be rationally engineered to meet specific requirements. In recent decades, adhesive hydrogels have experienced significant advancements driven by the introduction of numerous multifunctional design strategies. This review initially summarizes the chemical bond-based design strategies for tissue adhesion, encompassing static covalent bonds, dynamic covalent bonds, and non-covalent interactions. Subsequently, the multiple functionalities imparted by these diverse design strategies, including highly stretchable and tough performances, responsiveness to microenvironments, anti-freezing/heating properties, conductivity, antibacterial activity, and hemostatic properties are discussed. In addition, recent advances in the biomedical applications of adhesive hydrogels, focusing on tissue repair, drug delivery, medical devices, and wearable sensors are reviewed. Finally, the current challenges are highlighted and future trends in this rapidly evolving field are discussed.
Collapse
Affiliation(s)
- Shaoxin Tang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Keru Feng
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Rui Yang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Yang Cheng
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Meiyue Chen
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Hui Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, 710004, P. R. China
| | - Nianyuan Shi
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, Shaanxi Provincial Key Laboratory of Magnetic Medicine, Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004, P. R. China
| | - Zhao Wei
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Hui Ren
- Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004, P. R. China
| | - Yufei Ma
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| |
Collapse
|
3
|
Luo Q, Luo J, Luan Z, Xu K, Tian L, Zhang K, Peng X, Yuan M, Zheng C, Shu Z, Zhang Y, Tan S, Dan R, Mequanint K, Fan C, Xing M, Yang S. Blue Laser Triggered Hemostatic Peptide Hydrogel for Gastrointestinal Bleeding Treatment. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2405290. [PMID: 39011814 DOI: 10.1002/adma.202405290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Revised: 06/16/2024] [Indexed: 07/17/2024]
Abstract
In an emergency, nonvariceal upper gastrointestinal bleeding (NVUGIB), endoscopic hemostasis is considered the gold standard intervention. However, current endoscopic hemostasis is very challenging to manage bleeding in large-diameter or deep lesions highly prone to rebleeding risk. Herein, a novel hemostatic peptide hydrogel (HPH) is reported, consisting of a self-assembly peptide sequence CFLIVIGSIIVPGDGVPGDG (PFV) and gelatin methacryloyl (GelMA), which can be triggered by blue laser endoscopy (BLE) for nonvariceal upper gastrointestinal bleeding treatment without recurring bleeding concerns. Upon contact with GelMA solution, PFV immediately fibrillates into β-sheet nanofiber and solvent-induced self-assembly to form HPH gel. HPH nanofiber networks induced ultrafast coagulation by enveloping blood cells and activating platelets and coagulation factors even to the blood with coagulopathy. Besides its remarkable hemostatic performance in artery and liver injury models, HPH achieves instant bleeding management in porcine NVUGIB models within 60 s by preventing the rebleeding risk. This work demonstrates an extraordinary hemostatic agent for NVUGIB intervention by BLE for the first time, broadening potential application scenarios, including patients with coagulopathy and promising clinical prospects.
Collapse
Affiliation(s)
- Qiang Luo
- Department of Gastroenterology, Xinqiao Hospital, No. 183, Xinqiao Street, Chongqing, 400037, China
| | - Jie Luo
- Department of Gastroenterology, Xinqiao Hospital, No. 183, Xinqiao Street, Chongqing, 400037, China
| | - Zhaohui Luan
- Department of Gastroenterology, Xinqiao Hospital, No. 183, Xinqiao Street, Chongqing, 400037, China
| | - Kaige Xu
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, R3T 2N2, Manitoba, Canada
| | - Lixing Tian
- Department of Gastroenterology, Xinqiao Hospital, No. 183, Xinqiao Street, Chongqing, 400037, China
| | - Kebin Zhang
- Clinical Medical Research Center, Xinqiao Hospital, No.183, Xinqiao Street, Chongqing, 400037, China
| | - Xue Peng
- Department of Gastroenterology, Xinqiao Hospital, No. 183, Xinqiao Street, Chongqing, 400037, China
| | - Mengxue Yuan
- Department of Gastroenterology, Xinqiao Hospital, No. 183, Xinqiao Street, Chongqing, 400037, China
| | - Chuanhao Zheng
- Department of Gastroenterology, Xinqiao Hospital, No. 183, Xinqiao Street, Chongqing, 400037, China
| | - Zhenzhen Shu
- Department of Gastroenterology, Xinqiao Hospital, No. 183, Xinqiao Street, Chongqing, 400037, China
| | - Yuchen Zhang
- Department of Gastroenterology, Xinqiao Hospital, No. 183, Xinqiao Street, Chongqing, 400037, China
| | - Shali Tan
- Department of Gastroenterology, Xinqiao Hospital, No. 183, Xinqiao Street, Chongqing, 400037, China
| | - Ruijue Dan
- Department of Gastroenterology, Xinqiao Hospital, No. 183, Xinqiao Street, Chongqing, 400037, China
| | - Kibret Mequanint
- Department of Chemical and Biochemical Engineering, The University of Western Ontario, London, N6A 5B9, Canada
| | - Chaoqiang Fan
- Department of Gastroenterology, Xinqiao Hospital, No. 183, Xinqiao Street, Chongqing, 400037, China
| | - Malcolm Xing
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, R3T 2N2, Manitoba, Canada
| | - Shiming Yang
- Department of Gastroenterology, Xinqiao Hospital, No. 183, Xinqiao Street, Chongqing, 400037, China
- Chongqing Municipality Clinical Research Center for Gastroenterology, Chongqing, 400037, China
| |
Collapse
|
4
|
Liu L, Liu L, Chen L, Chen G, Wei Y, Hong FF. Synthesis of hemostatic aerogel of TEMPO-oxidized cellulose nanofibers/collagen/chitosan and in vivo/ vitro evaluation. Mater Today Bio 2024; 28:101204. [PMID: 39221199 PMCID: PMC11364910 DOI: 10.1016/j.mtbio.2024.101204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Revised: 08/04/2024] [Accepted: 08/13/2024] [Indexed: 09/04/2024] Open
Abstract
The treatment of internal hemorrhage remains challenging due to the current limited antibacterial capability, hemostatic efficacy, and biocompatibility of hemostatic materials. The TEMPO-oxidized cellulose nanofibers/collagen/chitosan (TCNF/COL/CS) hemostatic aerogel was developed in this work by physically encasing COL in a sandwich structure and electrostatically self-assembling polyanionic TCNF with polycationic CS. In vitro coagulation experiments revealed the favorable procoagulant properties of TCNF/COL/CS along with high adhesion to erythrocytes and platelets. TCNF/COL/CS significantly increased the hemostatic efficacy by 59.8 % and decreased blood loss by 62.2 % in the liver injury model when compared to Surgicel®, the most frequently used hemostatic material. Furthermore, it demonstrated outstanding biodegradability both in vitro and in vivo, and a substantial increase in resistance (96.8 % against E. coli and 95.4 % against S. aureus) compared to TCNF. The significant hemostatic and biodegradable characteristics of TCNF/COL/CS can be ascribed to its interconnected porous structure, increased porosity, and efficient water absorption, along with the synergistic effect of the three constituents. The TCNF/COL/CS aerogel shows significant potential to control internal bleeding. A novel plant-derived nanocellulose composite aerogel has been described here for the first time; it has outstanding antibacterial characteristics, higher biocompatibility, and outstanding hemostatic characteristics in vivo.
Collapse
Affiliation(s)
- Lu Liu
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Donghua University, Shanghai, 201620, China
- College of Biological Science and Medical Engineering, Donghua University, No.2999 North Ren Min Road, Shanghai, 201620, China
| | - Liang Liu
- College of Biological Science and Medical Engineering, Donghua University, No.2999 North Ren Min Road, Shanghai, 201620, China
| | - Lin Chen
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Donghua University, Shanghai, 201620, China
| | - Genqiang Chen
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Donghua University, Shanghai, 201620, China
- College of Biological Science and Medical Engineering, Donghua University, No.2999 North Ren Min Road, Shanghai, 201620, China
| | - Yen Wei
- Department of Chemistry and the Tsinghua Center for Frontier Polymer Research, Tsinghua University, Beijing, 100084, China
| | - Feng F. Hong
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Donghua University, Shanghai, 201620, China
- College of Biological Science and Medical Engineering, Donghua University, No.2999 North Ren Min Road, Shanghai, 201620, China
- National Advanced Functional Fiber Innovation Center, WuJiang, Suzhou, China
- Scientific Research Base for Bacterial Nanofiber Manufacturing and Composite Technology, China Textile Engineering Society, Shanghai, 201620, China
| |
Collapse
|
5
|
Zhou M, Yuan T, Shang L. 3D Printing of Naturally Derived Adhesive Hemostatic Sponge. RESEARCH (WASHINGTON, D.C.) 2024; 7:0446. [PMID: 39119591 PMCID: PMC11309851 DOI: 10.34133/research.0446] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/21/2024] [Accepted: 07/17/2024] [Indexed: 08/10/2024]
Abstract
Hydrogel hemostatic sponges have been recognized for its effectiveness in wound treatment due to its excellent biocompatibility, degradability, as well as multi-facet functionalities. Current research focuses on optimizing the composition and structure of the sponge to enhance its therapeutic effectiveness. Here, we propose an adhesive hydrogel made from purely natural substances extracted from okra and Panax notoginseng. We utilize 3-dimensional (3D) printing technology to fabricate the hemostatic hydrogel scaffold, incorporating gelatin into the hydrogel and refining the mixing ratio. The interaction between gelatin and okra polyphenols contributes to successful injectability as well as stability of the printed scaffold. The okra in the scaffold exhibits favorable adhesion and hemostatic effects, and the total saponins of Panax notoginseng facilitate angiogenesis. Through in vitro experiments, we have substantiated the scaffold's excellent stability, adhesion, biocompatibility, and angiogenesis-promoting ability. Furthermore, in vivo experiments have demonstrated its dual functionality in rapid hemostasis and wound repair. These features suggest that the 3D-printed, natural substance-derived hydrogel scaffolds have valuable potential in wound healing and related applications.
Collapse
Affiliation(s)
- Minyu Zhou
- The First Affiliated Hospital of Wenzhou Medical University, Wenzhou 325035, China
| | - Tao Yuan
- Department of Spine Surgery,
Second Xiangya Hospital of Central South University, Changsha 410011, China
| | - Luoran Shang
- The First Affiliated Hospital of Wenzhou Medical University, Wenzhou 325035, China
- Shanghai Xuhui Central Hospital, Zhongshan-Xuhui Hospital, and the Shanghai Key Laboratory of Medical Epigenetics, the International Co-laboratory of Medical Epigenetics and Metabolism (Ministry of Science and Technology), Institutes of Biomedical Sciences,
Fudan University, Shanghai, China
| |
Collapse
|
6
|
Shu Z, Liu E, Huang Y, Luo Q, Wang T, Li X, Mequanint K, Yang S, Xing M, Fan C. Analyzing Mushroom Structural Patterns of a Highly Compressible and Expandable Hemostatic Foam for Gastric Perforation Repair. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2306917. [PMID: 38439601 DOI: 10.1002/advs.202306917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 12/10/2023] [Indexed: 03/06/2024]
Abstract
Nature presents the most beautiful patterns through evolving. Here, a layered porous pattern in golden ratio (0.618) is reported from a type of mushroom -Dictyophora Rubrovalvata stipe (DRS). The hierarchical structure shows a mathematical correlation with the golden ratio. This unique structure leads to superior mechanical properties. The gradient porous structure from outside to innermost endows it with asymmetrical hydrophilicity. A mathematical model is then developed to predict and apply to 3D printed structures. The mushroom is then explored to repair gastric perforation because the stomach is a continuous peristaltic organ, and the perforated site is subject to repeated mechanical movements and pressure changes. At present, endoscopic clipping is ineffective in treating ulcerative perforation with fragile surrounding tissues. Although endoscopic implant occlusion provides a new direction for the treatment of gastric ulcers, but the metal or plastic occluder needs to be removed, requiring a second intervention. Decellularized DRS (DDRS) is found with asymmetric water absorption rate, super-compressive elasticity, shape memory, and biocompatibility, making it a suitable occluder for the gastric perforation. The efficacy in blocking gastric perforation and promoting healing is confirmed by endoscopic observation and tissue analysis during a 2-month study.
Collapse
Affiliation(s)
- Zhenzhen Shu
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
| | - En Liu
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
| | - Yu Huang
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
| | - Qiang Luo
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
| | - Tongchuan Wang
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
| | - Xin Li
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
| | - Kibret Mequanint
- Department of Chemical and Biochemical Engineering, and School of Biomedical Engineering, The University of Western Ontario, London, Ontario, N6A 5B9, Canada
| | - Shiming Yang
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
- Chongqing Municipality Clinical Research Center for Gastroenterology, Chongqing, 400037, China
| | - Malcolm Xing
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, Manitoba, R3T 2N2, Canada
| | - Chaoqiang Fan
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
- Chongqing Municipality Clinical Research Center for Gastroenterology, Chongqing, 400037, China
| |
Collapse
|
7
|
Sacramento MMA, Oliveira MB, Gomes JR, Borges J, Freedman BR, Mooney DJ, Rodrigues JMM, Mano JF. Natural Polymer-Polyphenol Bioadhesive Coacervate with Stable Wet Adhesion, Antibacterial Activity, and On-Demand Detachment. Adv Healthc Mater 2024; 13:e2304587. [PMID: 38334308 PMCID: PMC11469155 DOI: 10.1002/adhm.202304587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 02/02/2024] [Indexed: 02/10/2024]
Abstract
Medical adhesives are emerging as an important clinical tool as adjuvants for sutures and staples in wound closure and healing and in the achievement of hemostasis. However, clinical adhesives combining cytocompatibility, as well as strong and stable adhesion in physiological conditions, are still in demand. Herein, a mussel-inspired strategy is explored to produce adhesive coacervates using tannic acid (TA) and methacrylate pullulan (PUL-MA). TA|PUL-MA coacervates mainly comprise van der Waals forces and hydrophobic interactions. The methacrylic groups in the PUL backbone increase the number of interactions in the adhesives matrix, resulting in enhanced cohesion and adhesion strength (72.7 Jm-2), compared to the non-methacrylated coacervate. The adhesive properties are kept in physiologic-mimetic solutions (72.8 Jm-2) for 72 h. The photopolymerization of TA|PUL-MA enables the on-demand detachment of the adhesive. The poor cytocompatibility associated with the use of phenolic groups is here circumvented by mixing reactive oxygen species-degrading enzyme in the adhesive coacervate. This addition does not hamper the adhesive character of the materials, nor their anti-microbial or hemostatic properties. This affordable and straightforward methodology, together with the tailorable adhesivity even in wet environments, high cytocompatibility, and anti-bacterial activity, enables foresee TA|PUL-MA as a promising ready-to-use bioadhesive for biomedical applications.
Collapse
Affiliation(s)
- Margarida M. A. Sacramento
- CICECO – Aveiro Institute of MaterialsDepartment of ChemistryUniversity of AveiroCampus Universitário de SantiagoAveiro3810‐193Portugal
| | - Mariana B. Oliveira
- CICECO – Aveiro Institute of MaterialsDepartment of ChemistryUniversity of AveiroCampus Universitário de SantiagoAveiro3810‐193Portugal
| | - José R.B. Gomes
- CICECO – Aveiro Institute of MaterialsDepartment of ChemistryUniversity of AveiroCampus Universitário de SantiagoAveiro3810‐193Portugal
| | - João Borges
- CICECO – Aveiro Institute of MaterialsDepartment of ChemistryUniversity of AveiroCampus Universitário de SantiagoAveiro3810‐193Portugal
| | - Benjamin R. Freedman
- John A. Paulson School of Engineering and Applied SciencesHarvard UniversityCambridgeMA02138USA
- Wyss Institute for Biologically Inspired EngineeringHarvard UniversityCambridgeMA02138USA
- Department of Orthopaedic SurgeryBeth Israel Deaconess Medical CenterHarvard Medical SchoolBostonMA02215USA
| | - David J. Mooney
- John A. Paulson School of Engineering and Applied SciencesHarvard UniversityCambridgeMA02138USA
- Wyss Institute for Biologically Inspired EngineeringHarvard UniversityCambridgeMA02138USA
| | - João M. M. Rodrigues
- CICECO – Aveiro Institute of MaterialsDepartment of ChemistryUniversity of AveiroCampus Universitário de SantiagoAveiro3810‐193Portugal
| | - João F. Mano
- CICECO – Aveiro Institute of MaterialsDepartment of ChemistryUniversity of AveiroCampus Universitário de SantiagoAveiro3810‐193Portugal
| |
Collapse
|
8
|
Ito S, Nagasaka K, Komatsu H, Palai D, Nishiguchi A, Taguchi T. Improved hydration property of tissue adhesive/hemostatic microparticle based on hydrophobically-modified Alaska pollock gelatin. BIOMATERIALS ADVANCES 2024; 159:213834. [PMID: 38518390 DOI: 10.1016/j.bioadv.2024.213834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 03/11/2024] [Accepted: 03/17/2024] [Indexed: 03/24/2024]
Abstract
The management of bleeding is an important aspect of endoscopic surgery to avoid excessive blood loss and minimize pain. In clinical settings, sprayable hemostatic particles are used for their easy delivery, adaptability to irregular shapes, and rapid hydration. However, conventional hemostatic particles present challenges associated with tissue adhesion. In a previous study, we reported tissue adhesive microparticles (C10-sa-MPs) derived from Alaska pollock gelatin modified with decyl groups (C10-sa-ApGltn) using secondary amines as linkages. The C10-sa-MPs adhere to soft tissues through a hydration mechanism. However, their application as a hemostatic agent was limited by their long hydration times, attributed to their high hydrophobicity. In this study, we present a new type microparticle, C10-am-MPs, synthesized by incorporating decanoyl group modifications into ApGltn (C10-am-ApGltn), using amide bonds as linkages. C10-am-MPs exhibited enhanced hydration characteristics compared to C10-sa-MPs, attributed to superior water absorption facilitated by amide bonds rather than secondary amines. Furthermore, C10-am-MPs demonstrated comparable tissue adhesion properties and underwater adhesion stability to C10-sa-MPs. Notably, C10-am-MPs exhibited accelerated blood coagulation in vitro compared to C10-sa-MPs. The application of C10-am-MPs in an in vivo rat liver hemorrhage model resulted in a hemostatic effect comparable to a commercially available hemostatic particle. These findings highlight the potential utility of C10-am-MPs as an effective hemostatic agent for endoscopic procedures and surgical interventions.
Collapse
Affiliation(s)
- Shima Ito
- Biomaterials field, Research Center for Macromolecules and Biomaterials, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044, Japan; Graduate School of Science and Technology, Degree Programs in Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8577, Japan
| | - Kazuhiro Nagasaka
- Biomaterials field, Research Center for Macromolecules and Biomaterials, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044, Japan; Graduate School of Science and Technology, Degree Programs in Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8577, Japan
| | - Hiyori Komatsu
- Biomaterials field, Research Center for Macromolecules and Biomaterials, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044, Japan; Graduate School of Science and Technology, Degree Programs in Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8577, Japan
| | - Debabrata Palai
- Biomaterials field, Research Center for Macromolecules and Biomaterials, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044, Japan
| | - Akihiro Nishiguchi
- Biomaterials field, Research Center for Macromolecules and Biomaterials, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044, Japan
| | - Tetsushi Taguchi
- Biomaterials field, Research Center for Macromolecules and Biomaterials, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044, Japan; Graduate School of Science and Technology, Degree Programs in Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8577, Japan.
| |
Collapse
|
9
|
Zhang S, Lei X, Lv Y, Wang L, Wang LN. Recent advances of chitosan as a hemostatic material: Hemostatic mechanism, material design and prospective application. Carbohydr Polym 2024; 327:121673. [PMID: 38171686 DOI: 10.1016/j.carbpol.2023.121673] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/15/2023] [Accepted: 12/05/2023] [Indexed: 01/05/2024]
Abstract
Uncontrolled hemorrhage arising from surgery or trauma may cause morbidity and even mortality. Therefore, facilitating control of severe bleeding is imperative for health care worldwide. Among diverse hemostatic materials, chitosan (CS) is becoming the most promising material owing to its non-toxic feature, as well as inherently hemostatic performance. However, further enhancing hemostatic property of CS-based materials without compromising more beneficial functions remains a challenge. In this review, representative hemostatic mechanisms of CS-based materials are firstly discussed in detail, mostly including red blood cells (RBCs) aggregation, platelet adherence and aggregation, as well as interaction with plasma proteins. Also, various forms (involving powder/particle, sponge, hydrogel, nanofiber, and other forms) of CS-based hemostatic materials are systematically summarized, mainly focusing on their design and preparation, characteristics, and comparative analysis of various forms. In addition, varied hemostatic applications are described in detail, such as skin wound hemostasis, liver hemostasis, artery hemostasis, and heart hemostasis. Finally, current challenges and future directions of functional design of CS-based hemostatic materials in diverse hemostatic applications are proposed to inspire more intensive researches.
Collapse
Affiliation(s)
- Shuxiang Zhang
- Beijing Advanced Innovation Center for Materials Genome Engineering, State Key Laboratory for Advanced Metals and Materials, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, PR China
| | - Xiuxue Lei
- Beijing Advanced Innovation Center for Materials Genome Engineering, State Key Laboratory for Advanced Metals and Materials, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, PR China
| | - Yongle Lv
- Beijing Advanced Innovation Center for Materials Genome Engineering, State Key Laboratory for Advanced Metals and Materials, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, PR China
| | - Lei Wang
- Beijing Advanced Innovation Center for Materials Genome Engineering, State Key Laboratory for Advanced Metals and Materials, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, PR China.
| | - Lu-Ning Wang
- Beijing Advanced Innovation Center for Materials Genome Engineering, State Key Laboratory for Advanced Metals and Materials, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, PR China; Institute of Materials Intelligent Technology, Liaoning Academy of Materials, Shenyang 110004, PR China.
| |
Collapse
|
10
|
Zhao W, Sun W, Wang W, Zhang Y, Ma Q. Robust and Wet Adhesive Self-Gelling Powders for Rapid Hemostasis and Efficient Wound Healing. ACS APPLIED MATERIALS & INTERFACES 2024; 16:6756-6771. [PMID: 38291577 DOI: 10.1021/acsami.3c14944] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2024]
Abstract
Healing traumatic wounds is arduous, leaving miscellaneous demands for ideal wound dressings, such as rapid hemostasis, superior wet tissue adhesion, strong mechanical properties, and excellent antibacterial activity. Herein, we report a self-gelling, wet adhesive, stretchable (polyethylenimine/poly(dimethylammonium chloride)/(poly(acrylic acid)/poly(sodium styrenesulfonate)/alkylated chitosan)) ((PEI/PDDA)/(PAA/PSS)/ACS) powder as a new option. The self-gel utilizes noncovalent interactions among in situ formed PDDA/PSS nanoparticles and PEI/PAA polymetric matrices to earn sensational mechanical properties and tensile strength while incorporating ACS to obtain fast hemostasis and therapeutic capacities. The powder can form a hydrogel patch in situ within 3 s upon liquid absorption, capable of resisting pressure higher than twice the blood pressure. Deposition of the self-gelling powders on various wounds, such as rat liver and femoral artery wounds, can stop bleeding in 10 s and lessen the amount of bleeding 6-fold plus in corresponding models. Furthermore, the self-gelling powders can significantly advance the chronic wound healing process by displaying a high wound healing rate and a low inflammatory response and promoting the formation of new blood vessels and tissue regeneration. The satisfactory mechanical properties, strong wet adhesion, sufficient antibacterial properties, ease of usage, adaptability to complex wounds, rapid hemostasis, and superior therapeutic capacities of (PEI/PDDA)/(PAA/PSS)/ACS self-gelling powders render them as a profound wound dressing biomaterial.
Collapse
Affiliation(s)
- Wenbin Zhao
- School of Pharmacy, Qingdao University, Qingdao 266071, P. R. China
| | - Wentao Sun
- School of Health and Life Sciences, University of Health and Rehabilitation Sciences, Qingdao 266113, P. R. China
| | - Weijiang Wang
- School of Pharmacy, Qingdao University, Qingdao 266071, P. R. China
| | - Yage Zhang
- Guangdong Key Laboratory of Biomedical Measurements and Ultrasound School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, Shenzhen, Guangdong 518055, China
| | - Qingming Ma
- School of Pharmacy, Qingdao University, Qingdao 266071, P. R. China
| |
Collapse
|
11
|
Ito T, Mizuta R, Ito S, Taguchi T. Robust aortic media adhesion using hydrophobically modified Alaska pollock gelatin-based adhesive for aortic dissections. J Biomed Mater Res B Appl Biomater 2024; 112:e35361. [PMID: 38247245 DOI: 10.1002/jbm.b.35361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 11/11/2023] [Accepted: 11/29/2023] [Indexed: 01/23/2024]
Abstract
Type-A aortic dissection is an acute injury involving the delamination of the aorta at the parts of the aortic media. Aldehyde crosslinker-containing glues have been used to adhere to the media of the dissected aorta before joining an artificial graft. These glues effectively adhere to the aortic media; however, they show low biocompatibility due to the release of aldehyde compounds. In this study, we report innovative adhesives based on hydrophobically modified Alaska pollock gelatin (hm-ApGltn) with different alkyl or cholesteryl (Chol) groups that adhere to the media of the dissected aorta by combining hm-ApGltns with a biocompatible crosslinker, pentaerythritol poly(ethylene glycol) ether tetrasuccinimidyl glutarate. The modification of alkyl or Chol groups contributed to enhanced adhesion strength between porcine aortic media. The adhesion strength increased with increasing modification ratios of alkyl groups from propanoyl to dodecanoyl groups and then decreased at a modification ratio of ~20 mol %. Porcine aortic media adhered using 7.5Chol-ApGltn adhesive showed stretchability even when expanded and shrunk vertically by 25% at least five times. Hm-ApGltn adhesives subcutaneously injected into the backs of mice showed no severe inflammation and were degraded during the implantation period. These results indicated that hm-ApGltn adhesives have potential applications in type-A aortic dissection.
Collapse
Affiliation(s)
- Temmei Ito
- Graduate School of Pure and Applied Sciences, University of Tsukuba, Tsukuba, Japan
- Biomaterials Field, Research Center for Macromolecules and Biomaterials, National Institute for Materials Science, Tsukuba, Japan
| | - Ryo Mizuta
- Graduate School of Pure and Applied Sciences, University of Tsukuba, Tsukuba, Japan
- Biomaterials Field, Research Center for Macromolecules and Biomaterials, National Institute for Materials Science, Tsukuba, Japan
| | - Shima Ito
- Graduate School of Pure and Applied Sciences, University of Tsukuba, Tsukuba, Japan
- Biomaterials Field, Research Center for Macromolecules and Biomaterials, National Institute for Materials Science, Tsukuba, Japan
| | - Tetsushi Taguchi
- Graduate School of Pure and Applied Sciences, University of Tsukuba, Tsukuba, Japan
- Biomaterials Field, Research Center for Macromolecules and Biomaterials, National Institute for Materials Science, Tsukuba, Japan
| |
Collapse
|
12
|
Rayatdoost F, Grottke O. The Use of Large Animal Models in Trauma and Bleeding Studies. Hamostaseologie 2023; 43:360-373. [PMID: 37696297 DOI: 10.1055/a-2118-1431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/13/2023] Open
Abstract
BACKGROUND Major trauma often results in significant bleeding and coagulopathy, posing a substantial clinical burden. To understand the underlying pathophysiology and to refine clinical strategies to overcome coagulopathy, preclinical large animal models are often used. This review scrutinizes the clinical relevance of large animal models in hemostasis research, emphasizing challenges in translating findings into clinical therapies. METHODS We conducted a thorough search of PubMed and EMBASE databases from January 1, 2010, to December 31, 2022. We used specific keywords and inclusion/exclusion criteria centered on large animal models. RESULTS Our review analyzed 84 pertinent articles, including four animal species: pigs, sheep, dogs, and nonhuman primates (NHPs). Eighty-five percent of the studies predominantly utilized porcine models. Meanwhile, sheep and dogs were less represented, making up only 2.5% of the total studies. Models with NHP were 10%. The most frequently used trauma models involved a combination of liver injury and femur fractures (eight studies), arterial hemorrhage (seven studies), and a combination of hemodilution and liver injury (seven studies). A wide array of coagulation parameters were employed to assess the efficacy of interventions in hemostasis and bleeding control. CONCLUSIONS Recognizing the diverse strengths and weaknesses of large animal models is critical for trauma and hemorrhage research. Each model is unique and should be chosen based on how well it aligns with the specific scientific objectives of the study. By strategically considering each model's advantages and limitations, we can enhance our understanding of trauma and hemorrhage pathophysiology and further advance the development of effective treatments.
Collapse
Affiliation(s)
- Farahnaz Rayatdoost
- Department of Anaesthesiology, University Hospital RWTH Aachen, Aachen, Germany
| | - Oliver Grottke
- Department of Anaesthesiology, University Hospital RWTH Aachen, Aachen, Germany
| |
Collapse
|
13
|
Wang W, Luan Z, Shu Z, Xu K, Wang T, Liu S, Wu X, Liu H, Ye S, Dan R, Zhao X, Yang S, Xing M, Fan C. Biosynthetic Plastics as Tunable Elastic and Visible Stent with Shape-Memory to Treat Biliary Stricture. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2303779. [PMID: 37552006 PMCID: PMC10582434 DOI: 10.1002/advs.202303779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Indexed: 08/09/2023]
Abstract
Common biliary tract is ≈4 mm in diameter to deliver bile from liver to small intestine to help digestion. The abnormal narrowing leads to severe symptoms such as pain and nausea. Stents are an effective treatment. Compared with non-degradable stents which require repeated removal, biodegradable stents have the advantage of reducing secondary injury related to endoscopic operation and patient burden. However, current biodegradable materials may cause tissue hyperplasia and the treatment method does not target etiology of stricture. So recurrence rates after biodegradable stent implantation are still high. Here, a biodegradable helical stent fabricated from biosynthetic P(3HB-co-4HB) is reported. Tunable properties can be acquired through altering culture substrates. Stent shows shape memory in various solvents. The stent has an optimized design with helical structure and outer track. The self-expanding of helical structure and double drainage realized by outer track greatly improve drainage of bile. Importantly, stent-loading triamcinolone acetonide can inhibit proliferation of fibroblasts and reduce incidence of restricture. Therapeutic effect is also demonstrated in minipigs with biliary stricture. The results of minipig experiments show that biliary duct in treatment group is unobstructed and tissue hyperplasia is effectively inhibited.
Collapse
Affiliation(s)
- Wei Wang
- Department of GastroenterologyXinqiao HospitalArmy Medical UniversityNO.183, Xinqiao StreetChongqing400037China
| | - Zhaohui Luan
- Department of GastroenterologyXinqiao HospitalArmy Medical UniversityNO.183, Xinqiao StreetChongqing400037China
| | - Zhenzhen Shu
- Department of GastroenterologyXinqiao HospitalArmy Medical UniversityNO.183, Xinqiao StreetChongqing400037China
| | - Kaige Xu
- Department of Mechanical EngineeringUniversity of ManitobaWinnipegManitobaMB R3T 2N2Canada
| | - Tongchuan Wang
- Department of GastroenterologyXinqiao HospitalArmy Medical UniversityNO.183, Xinqiao StreetChongqing400037China
| | - Shuang Liu
- Department of GastroenterologyXinqiao HospitalArmy Medical UniversityNO.183, Xinqiao StreetChongqing400037China
| | - Xiaozhuo Wu
- Department of Mechanical EngineeringUniversity of ManitobaWinnipegManitobaMB R3T 2N2Canada
| | - Hangzong Liu
- Department of GastroenterologyXinqiao HospitalArmy Medical UniversityNO.183, Xinqiao StreetChongqing400037China
| | - Shaosong Ye
- Department of GastroenterologyXinqiao HospitalArmy Medical UniversityNO.183, Xinqiao StreetChongqing400037China
| | - Ruijue Dan
- Department of GastroenterologyXinqiao HospitalArmy Medical UniversityNO.183, Xinqiao StreetChongqing400037China
| | - Xiaoyan Zhao
- Department of GastroenterologyXinqiao HospitalArmy Medical UniversityNO.183, Xinqiao StreetChongqing400037China
| | - Shiming Yang
- Department of GastroenterologyXinqiao HospitalArmy Medical UniversityNO.183, Xinqiao StreetChongqing400037China
- Chongqing Municipality Clinical Research Center for Gastroenterology, Office of Science and Technology of ChongqingNo. 2 Xingai roadChongqing, Yubei401147China
- Chongqing Institute for Brain and Intelligence, Guangyang Bay LaboratoryChongqing400064China
| | - Malcolm Xing
- Department of Mechanical EngineeringUniversity of ManitobaWinnipegManitobaMB R3T 2N2Canada
| | - Chaoqiang Fan
- Department of GastroenterologyXinqiao HospitalArmy Medical UniversityNO.183, Xinqiao StreetChongqing400037China
- Chongqing Municipality Clinical Research Center for Gastroenterology, Office of Science and Technology of ChongqingNo. 2 Xingai roadChongqing, Yubei401147China
| |
Collapse
|
14
|
Luo Y, Li X, Zhao Y, Zhong W, Xing M, Lyu G. Development of Organs-on-Chips and Their Impact on Precision Medicine and Advanced System Simulation. Pharmaceutics 2023; 15:2094. [PMID: 37631308 PMCID: PMC10460056 DOI: 10.3390/pharmaceutics15082094] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 07/28/2023] [Accepted: 08/02/2023] [Indexed: 08/27/2023] Open
Abstract
Drugs may undergo costly preclinical studies but still fail to demonstrate their efficacy in clinical trials, which makes it challenging to discover new drugs. Both in vitro and in vivo models are essential for disease research and therapeutic development. However, these models cannot simulate the physiological and pathological environment in the human body, resulting in limited drug detection and inaccurate disease modelling, failing to provide valid guidance for clinical application. Organs-on-chips (OCs) are devices that serve as a micro-physiological system or a tissue-on-a-chip; they provide accurate insights into certain functions and the pathophysiology of organs to precisely predict the safety and efficiency of drugs in the body. OCs are faster, more economical, and more precise. Thus, they are projected to become a crucial addition to, and a long-term replacement for, traditional preclinical cell cultures, animal studies, and even human clinical trials. This paper first outlines the nature of OCs and their significance, and then details their manufacturing-related materials and methodology. It also discusses applications of OCs in drug screening and disease modelling and treatment, and presents the future perspective of OCs.
Collapse
Affiliation(s)
- Ying Luo
- Burn & Trauma Treatment Center, The Affiliated Hospital of Jiangnan University, Wuxi 214000, China; (Y.L.); (X.L.)
- Engineering Research Center of the Ministry of Education for Wound Repair Technology, Jiangnan University, Wuxi 214000, China
- Wuxi School of Medicine, Jiangnan University, Wuxi 214000, China
| | - Xiaoxiao Li
- Burn & Trauma Treatment Center, The Affiliated Hospital of Jiangnan University, Wuxi 214000, China; (Y.L.); (X.L.)
- Engineering Research Center of the Ministry of Education for Wound Repair Technology, Jiangnan University, Wuxi 214000, China
- Wuxi School of Medicine, Jiangnan University, Wuxi 214000, China
- Department of General Surgery, Huai’an 82 Hospital, Huai’an 223003, China
| | - Yawei Zhao
- Department of Biosystems Engineering, University of Manitoba, Winnipeg, MB R3T 2N2, Canada; (Y.Z.); (W.Z.)
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB R3T 2N2, Canada
| | - Wen Zhong
- Department of Biosystems Engineering, University of Manitoba, Winnipeg, MB R3T 2N2, Canada; (Y.Z.); (W.Z.)
| | - Malcolm Xing
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB R3T 2N2, Canada
| | - Guozhong Lyu
- Burn & Trauma Treatment Center, The Affiliated Hospital of Jiangnan University, Wuxi 214000, China; (Y.L.); (X.L.)
- Engineering Research Center of the Ministry of Education for Wound Repair Technology, Jiangnan University, Wuxi 214000, China
- Wuxi School of Medicine, Jiangnan University, Wuxi 214000, China
- National Research Center for Emergency Medicine, Beijing 100000, China
| |
Collapse
|
15
|
Zhou F, Xin L, Wang S, Chen K, Li D, Wang S, Huang Y, Xu C, Zhou M, Zhong W, Wang H, Chen T, Song J. Portable Handheld "SkinPen" Loaded with Biomaterial Ink for In Situ Wound Healing. ACS APPLIED MATERIALS & INTERFACES 2023. [PMID: 37262337 DOI: 10.1021/acsami.3c02825] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In situ bioprinting has emerged as an attractive tool for directly depositing therapy ink at the defective area to adapt to the irregular wound shape. However, traditional bioprinting exhibits an obvious limitation in terms of an unsatisfactory bioadhesive effect. Here, a portable handheld bioprinter loaded with biomaterial ink is designed and named "SkinPen". Gelatin methacrylate (GelMA) and Cu-containing bioactive glass nanoparticles (Cu-BGn) serve as the main components to form the hydrogel ink, which displays excellent biocompatibility and antibacterial and angiogenic properties. More importantly, by introducing ultrasound and ultraviolet in a sequential programmed manner, the SkinPen achieves in situ instant gelation and amplified (more than threefold) bioadhesive shear strength. It is suggested that ultrasound-induced cavitation and the resulting topological entanglement contribute to the enhanced bioadhesive performance together. Combining the ultrasound-enhanced bioadhesion with the curative role of the hydrogel, the SkinPen shows a satisfactory wound-healing effect in diabetic rats. Given the detachable property of the SkinPen, the whole device can be put in a first-aid kit. Therefore, the application scenarios can be expanded to many kinds of accidents. Overall, this work presents a portable handheld SkinPen that might provide a facile but effective approach for clinical wound management.
Collapse
Affiliation(s)
- Fuyuan Zhou
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, P. R. China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, P. R. China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing 401147, P. R. China
| | - Liangjing Xin
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, P. R. China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, P. R. China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing 401147, P. R. China
| | - Shuya Wang
- Key State Laboratory of Fine Chemicals, Dalian 116024, P. R. China
- School of Bioengineering, Dalian University of Technology, Dalian 116024, P. R. China
| | - Kaiwen Chen
- Key State Laboratory of Fine Chemicals, Dalian 116024, P. R. China
- School of Bioengineering, Dalian University of Technology, Dalian 116024, P. R. China
| | - Dize Li
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, P. R. China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, P. R. China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing 401147, P. R. China
| | - Si Wang
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, P. R. China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, P. R. China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing 401147, P. R. China
| | - Yuanding Huang
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, P. R. China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, P. R. China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing 401147, P. R. China
| | - Chuanhang Xu
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, P. R. China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, P. R. China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing 401147, P. R. China
| | - Mengjiao Zhou
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, P. R. China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, P. R. China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing 401147, P. R. China
| | - Wenjie Zhong
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, P. R. China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, P. R. China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing 401147, P. R. China
| | - Huanan Wang
- Key State Laboratory of Fine Chemicals, Dalian 116024, P. R. China
- School of Bioengineering, Dalian University of Technology, Dalian 116024, P. R. China
| | - Tao Chen
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, P. R. China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, P. R. China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing 401147, P. R. China
| | - Jinlin Song
- Stomatological Hospital of Chongqing Medical University, Chongqing 401147, P. R. China
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing 401147, P. R. China
- Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing 401147, P. R. China
| |
Collapse
|
16
|
Zhou Y, Yang L, Liu Z, Sun Y, Huang J, Liu B, Wang Q, Wang L, Miao Y, Xing M, Hu Z. Reversible adhesives with controlled wrinkling patterns for programmable integration and discharging. SCIENCE ADVANCES 2023; 9:eadf1043. [PMID: 37043582 PMCID: PMC10096647 DOI: 10.1126/sciadv.adf1043] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 03/10/2023] [Indexed: 06/19/2023]
Abstract
Switchable and minimally invasive tissue adhesives have great potential for medical applications. However, on-demand adherence to and detachment from tissue surfaces remain difficult. We fabricated a switchable hydrogel film adhesive by designing pattern-tunable wrinkles to control adhesion. When adhered to a substrate, the compressive stress generated from the bilayer system leads to self-similar wrinkling patterns at short and long wavelengths, regulating the interfacial adhesion. To verify the concept and explore its application, we established a random skin flap model, which is a crucial strategy for repairing severe or large-scale wounds. Our hydrogel adhesive provides sufficient adhesion for tissue sealing and promotes neovascularization at the first stage, and then gradually detaches from the tissue while a dynamic wrinkling pattern transition happens. The gel film can be progressively ejected out from the side margins after host-guest integration. Our findings provide insights into tunable bioadhesion by manipulating the wrinkling pattern transition.
Collapse
Affiliation(s)
- Yi Zhou
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou 510515, P.R. China
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB R3T 2N2, Canada
| | - Lunan Yang
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou 510515, P.R. China
| | - Zhen Liu
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou 510515, P.R. China
| | - Yang Sun
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou 510515, P.R. China
| | - Junfei Huang
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou 510515, P.R. China
| | - Bingcheng Liu
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou 510515, P.R. China
| | - Quan Wang
- School of Civil Engineering, Shantou University, Shantou 515063, P.R. China
| | - Leyu Wang
- Guangdong Provincial Key Laboratory of Construction and Detection in Tissue Engineering, Biomaterials Research Center, School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, P.R. China
| | - Yong Miao
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou 510515, P.R. China
| | - Malcolm Xing
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB R3T 2N2, Canada
| | - Zhiqi Hu
- Department of Plastic and Aesthetic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou 510515, P.R. China
| |
Collapse
|
17
|
Liu S, Luan Z, Wang T, Xu K, Luo Q, Ye S, Wang W, Dan R, Shu Z, Huang Y, Mequanint K, Fan C, Xing M, Yang S. Endoscopy Deliverable and Mushroom-Cap-Inspired Hyperboloid-Shaped Drug-Laden Bioadhesive Hydrogel for Stomach Perforation Repair. ACS NANO 2023; 17:111-126. [PMID: 36343209 DOI: 10.1021/acsnano.2c05247] [Citation(s) in RCA: 36] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Gastrointestinal tract perforation is a full-thickness injury that causes bleeding and fatal infection of the peritoneum. This condition worsens in an acidic gastric environment which interferes with the normal coagulation cascade. Current endoscopic clips to repair gastric perforations are ineffective, and metal or plastic occluders need secondary surgery to remove them. Herein, we report a self-expandable, endoscopy deliverable, adhesive hydrogel to block gastric perforation. We found the nanosilica coating significantly enhanced the adhesive strength even under a simulated strong acidic stomach environment. The developed device was disulfide cross-linked for the reducible degraded gel. By loading with vonoprazan fumarate (VF) and acidic fibroblast growth factor (AFGF), the hyperboloid-shaped device can have a sustained drug release to regulate intragastric pH and promote wound healing. The gel device can be compressed and then expanded like a mushroom when applied in an acute gastric perforation model in both rabbits and minipigs. By utilizing a stomach capsule robot for remotely monitoring the pH and by immunohistochemical analysis, we demonstrated that the compressible hyperboloid-shaped gel could stably block the perforation and promoted wound healing during the 28 days of observation. The real-time pH meter demonstrated that the gel could control intragastric pH above 4 for nearly 60 h to prevent bleeding.
Collapse
Affiliation(s)
- Shuang Liu
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, No.183, Xinqiao Street, Shapingba District, Chongqing400037, China
| | - Zhaohui Luan
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, No.183, Xinqiao Street, Shapingba District, Chongqing400037, China
| | - Tongchuan Wang
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, No.183, Xinqiao Street, Shapingba District, Chongqing400037, China
| | - Kaige Xu
- Departments of Mechanical Engineering, University of Manitoba, Winnipeg, ManitobaR3T 2N2, Canada
| | - Qiang Luo
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, No.183, Xinqiao Street, Shapingba District, Chongqing400037, China
| | - Shaosong Ye
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, No.183, Xinqiao Street, Shapingba District, Chongqing400037, China
| | - Wei Wang
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, No.183, Xinqiao Street, Shapingba District, Chongqing400037, China
| | - Ruijue Dan
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, No.183, Xinqiao Street, Shapingba District, Chongqing400037, China
| | - Zhenzhen Shu
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, No.183, Xinqiao Street, Shapingba District, Chongqing400037, China
| | - Yu Huang
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, No.183, Xinqiao Street, Shapingba District, Chongqing400037, China
| | - Kibret Mequanint
- Department of Chemical and Biochemical Engineering, and School of Biomedical Engineering, The University of Western Ontario, London, OntarioN6A 5B9, Canada
| | - Chaoqiang Fan
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, No.183, Xinqiao Street, Shapingba District, Chongqing400037, China
- Chongqing Municipality Clinical Research Center for Gastroenterology, Chongqing400037, China
| | - Malcolm Xing
- Departments of Mechanical Engineering, University of Manitoba, Winnipeg, ManitobaR3T 2N2, Canada
| | - Shiming Yang
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, No.183, Xinqiao Street, Shapingba District, Chongqing400037, China
- Chongqing Municipality Clinical Research Center for Gastroenterology, Chongqing400037, China
| |
Collapse
|
18
|
Luan Z, Liu S, Wang W, Xu K, Ye S, Dan R, Zhang H, Shu Z, Wang T, Fan C, Xing M, Yang S. Aligned nanofibrous collagen membranes from fish swim bladder as a tough and acid-resistant suture for pH-regulated stomach perforation and tendon rupture. Biomater Res 2022; 26:60. [PMID: 36348451 PMCID: PMC9641846 DOI: 10.1186/s40824-022-00306-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Accepted: 10/10/2022] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND Wound closure in the complex body environment places higher requirements on suture's mechanical and biological performance. In the scenario of frequent mechanical gastric motility and extremely low pH, single functional sutures have limitations in dealing with stomach bleeding trauma where the normal healing will get deteriorated in acid. It necessitates to advance suture, which can regulate wounds, resist acid and intelligently sense stomach pH. METHODS Based on fish swim bladder, a double-stranded drug-loaded suture was fabricated. Its cytotoxicity, histocompatibility, mechanical properties, acid resistance and multiple functions were verified. Also, suture's performance suturing gastric wounds and Achilles tendon was verified in an in vivo model. RESULTS By investigating the swim bladder's multi-scale structure, the aligned tough collagen fibrous membrane can resist high hydrostatic pressure. We report that the multi-functional sutures on the twisted and aligned collagen fibers have acid resistance and low tissue reaction. Working with an implantable "capsule robot", the smart suture can inhibit gastric acid secretion, curb the prolonged stomach bleeding and monitor real-time pH changes in rabbits and pigs. The suture can promote stomach healing and is strong enough to stitch the fractured Achilles tendon. CONCLUSIONS As a drug-loaded absorbable suture, the suture shows excellent performance and good application prospect in clinical work.
Collapse
Affiliation(s)
- Zhaohui Luan
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
| | - Shuang Liu
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
| | - Wei Wang
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
| | - Kaige Xu
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada
| | - Shaosong Ye
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
| | - Ruijue Dan
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
| | - Hong Zhang
- Department of Gastroenterology, Affiliated Hospital of North Sichuan Medical College, Maoyuan Nan Road, Shunqing District, Nanchong City, Sichuan, China
| | - Zhenzhen Shu
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
| | - Tongchuan Wang
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China
| | - Chaoqiang Fan
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China.
- Chongqing Municipality Clinical Research Center for Gastroenterology, Chongqing, China.
| | - Malcolm Xing
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada.
| | - Shiming Yang
- Department of Gastroenterology, Xinqiao Hospital, Army Medical University, NO.183, Xinqiao Street, Chongqing, 400037, China.
- Chongqing Municipality Clinical Research Center for Gastroenterology, Chongqing, China.
| |
Collapse
|