1
|
Zhang X, Smith J, Zhou AC, Duong JTT, Qi T, Chen S, Lin YJ, Gill A, Lo CH, Lin NYC, Wen J, Lu Y, Chiou PY. Large-scale acoustic single cell trapping and selective releasing. LAB ON A CHIP 2025; 25:1537-1551. [PMID: 39901861 DOI: 10.1039/d4lc00736k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2025]
Abstract
Recent advancements in single-cell analysis have underscored the need for precise isolation and manipulation of individual cells. Traditional techniques for single-cell manipulation are often limited by the number of cells that can be parallel trapped and processed and usually require complex devices or instruments to operate. Here, we introduce an acoustic microfluidic platform that efficiently traps and selectively releases individual cells using spherical air cavities embedded in a polydimethylsiloxane (PDMS) substrate for large scale manipulation. Our device utilizes the principle of acoustic impedance mismatches to generate near-field acoustic potential gradients that create trapping sites for single cells. These single cell traps can be selectively disabled by illuminating a near-infrared laser pulse, allowing targeted release of trapped cells. This method ensures minimal impact on cell viability and proliferation, making it ideal for downstream single-cell analysis. Experimental results demonstrate our platform's capability to trap and release synthetic microparticles and biological cells with high efficiency and biocompatibility. Our device can handle a wide range of cell sizes (8-30 μm) across a large active manipulation area of 1 cm2 with 20 000 single-cell traps, providing a versatile and robust platform for single-cell applications. This acoustic microfluidic platform offers a cost-effective and practical method for large scale single-cell trapping and selective releasing with potential applications in genomics, proteomics, and other fields requiring precise single-cell manipulation.
Collapse
Affiliation(s)
- Xiang Zhang
- Department of Mechanical and Aerospace Engineering, University of California at Los Angeles, USA.
| | - Jacob Smith
- Department of Mechanical and Aerospace Engineering, University of California at Los Angeles, USA.
| | | | | | - Tong Qi
- Department of Chemical and Biomolecular Engineering, University of California at Los Angeles, USA
- Department of Microbiology, Immunology and Molecular Genetics, David Geffen School of Medicine, University of California at Los Angeles, USA
| | - Shilin Chen
- Department of Chemical and Biomolecular Engineering, University of California at Los Angeles, USA
- Department of Microbiology, Immunology and Molecular Genetics, David Geffen School of Medicine, University of California at Los Angeles, USA
| | - Yen-Ju Lin
- Department of Electrical and Computer Engineering, University of California at Los Angeles, USA
| | - Alexi Gill
- Department of Mechanical and Aerospace Engineering, University of California at Los Angeles, USA.
| | - Chih-Hui Lo
- Department of Bioengineering, University of California at Los Angeles, USA
| | - Neil Y C Lin
- Department of Mechanical and Aerospace Engineering, University of California at Los Angeles, USA.
- Department of Bioengineering, University of California at Los Angeles, USA
- Institute for Quantitative and Computational Biosciences, University of California at Los Angeles, USA
| | - Jing Wen
- Department of Microbiology, Immunology and Molecular Genetics, David Geffen School of Medicine, University of California at Los Angeles, USA
| | - Yunfeng Lu
- Department of Chemical and Biomolecular Engineering, University of California at Los Angeles, USA
| | - Pei-Yu Chiou
- Department of Mechanical and Aerospace Engineering, University of California at Los Angeles, USA.
| |
Collapse
|
2
|
Wu H, Luo R, Li Z, Tian Y, Yuan J, Su B, Zhou K, Yan C, Shi Y. Additively Manufactured Flexible Liquid Metal-Coated Self-Powered Magnetoelectric Sensors with High Design Freedom. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2307546. [PMID: 38145802 DOI: 10.1002/adma.202307546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 12/19/2023] [Indexed: 12/27/2023]
Abstract
Although additive manufacturing enables controllable structural design and customized performance for magnetoelectric sensors, their design and fabrication still require careful matching of the size and modulus between the magnetic and conductive components. Achieving magnetoelectric integration remains challenging, and the rigid coils limit the flexibility of the sensors. To overcome these obstacles, this study proposes a composite process combining selective laser sintering (SLS) and 3D transfer printing for fabricating flexible liquid metal-coated magnetoelectric sensors. The liquid metal forms a conformal conductive network on the SLS-printed magnetic lattice structure. Deformation of the structure alters the magnetic flux passing through it, thereby generating voltage. A reverse model segmentation and summation method is established to calculate the theoretical magnetic flux. The impact of the volume fraction, unit size, and height of the sensors on the voltage is studied, and optimization of these factors yields a maximum voltage of 45.6 µV. The sensor has excellent sensing performance with a sensitivity of 10.9 kPa-1 and a minimum detection pressure of 0.1 kPa. The voltage can be generated through various external forces. This work presents a significant advancement in fabricating liquid metal-based magnetoelectric sensors by improving their structural flexibility, magnetoelectric integration, and design freedom.
Collapse
Affiliation(s)
- Hongzhi Wu
- State Key Laboratory of Material Processing and Die and Mold Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, 430074, P. R. China
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Ruiying Luo
- State Key Laboratory of Material Processing and Die and Mold Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, 430074, P. R. China
| | - Zhuofan Li
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, 430074, P. R. China
| | - Yujia Tian
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Jiayi Yuan
- State Key Laboratory of Material Processing and Die and Mold Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, 430074, P. R. China
| | - Bin Su
- State Key Laboratory of Material Processing and Die and Mold Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, 430074, P. R. China
| | - Kun Zhou
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Chunze Yan
- State Key Laboratory of Material Processing and Die and Mold Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, 430074, P. R. China
| | - Yusheng Shi
- State Key Laboratory of Material Processing and Die and Mold Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, 430074, P. R. China
| |
Collapse
|
3
|
Sun Y, Liu Y, Sun D, Liu K, Li Y, Liu Y, Zhang S. A facile single-cell patterning strategy based on harbor-like microwell microfluidics. Biomed Mater 2024; 19:045018. [PMID: 38772387 DOI: 10.1088/1748-605x/ad4e83] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Accepted: 05/21/2024] [Indexed: 05/23/2024]
Abstract
Single-cell analysis is an effective method for conducting comprehensive heterogeneity studies ranging from cell phenotype to gene expression. The ability to arrange different cells in a predetermined pattern at single-cell resolution has a wide range of applications in cell-based analysis and plays an important role in facilitating interdisciplinary research by researchers in various fields. Most existing microfluidic microwell chips is a simple and straightforward method, which typically use small-sized microwells to accommodate single cells. However, this method imposes certain limitations on cells of various sizes, and the single-cell capture efficiency is relatively low without the assistance of external forces. Moreover, the microwells limit the spatiotemporal resolution of reagent replacement, as well as cell-to-cell communication. In this study, we propose a new strategy to prepare a single-cell array on a planar microchannel based on microfluidic flip microwells chip platform with large apertures (50 μm), shallow channels (50 μm), and deep microwells (50 μm). The combination of three configuration characteristics contributes to multi-cell trapping and a single-cell array within microwells, while the subsequent chip flipping accomplishes the transfer of the single-cell array to the opposite planar microchannel for cells adherence and growth. Further assisted by protein coating of bovine serum albumin and fibronectin on different layers, the single-cell capture efficiency in microwells is achieved at 92.1% ± 1%, while ultimately 85% ± 3.4% on planar microchannel. To verify the microfluidic flip microwells chip platform, the real-time and heterogeneous study of calcium release and apoptosis behaviours of single cells is carried out. To our knowledge, this is the first time that high-efficiency single-cell acquisition has been accomplished using a circular-well chip design that combines shallow channel, large aperture and deep microwell together. The chip is effective in avoiding the shearing force of high flow rates on cells, and the large apertures better allows cells to sedimentation. Therefore, this strategy owns the advantages of easy preparation and user-friendliness, which is especially valuable for researchers from different fields.
Collapse
Affiliation(s)
- Yingnan Sun
- Shandong Province Key Laboratory of Detection Technology for Tumor Makers, School of Medicine, Linyi University, Linyi 276005, People's Republic of China
| | - Yongshu Liu
- Shandong Province Key Laboratory of Detection Technology for Tumor Makers, School of Medicine, Linyi University, Linyi 276005, People's Republic of China
| | - Dezhi Sun
- Xinjiang Key Laboratory of Signal Detection and Processing, School of Computer Science and Technology, Xinjiang University, Urumqi 830046, People's Republic of China
| | - Kexin Liu
- Shandong Province Key Laboratory of Detection Technology for Tumor Makers, School of Medicine, Linyi University, Linyi 276005, People's Republic of China
| | - Yuyan Li
- Shandong Province Key Laboratory of Detection Technology for Tumor Makers, School of Medicine, Linyi University, Linyi 276005, People's Republic of China
| | - Yumin Liu
- Shandong Province Key Laboratory of Detection Technology for Tumor Makers, School of Medicine, Linyi University, Linyi 276005, People's Republic of China
| | - Shusheng Zhang
- Shandong Province Key Laboratory of Detection Technology for Tumor Makers, School of Medicine, Linyi University, Linyi 276005, People's Republic of China
| |
Collapse
|
4
|
Cheng CC, Chen YJ, Lin SH, Wang HM, Lin GP, Chung TK. Magnetic-Field-Assisted Electric-Field-Induced Domain Switching of a Magnetic Single Domain in a Multiferroic/Magnetoelectric Ni Nanochevron/[Pb(Mg 1/3Nb 2/3)O 3] 0.68-[PbTiO 3] 0.32 (PMN-PT) Layered Structure. MICROMACHINES 2023; 15:36. [PMID: 38258155 PMCID: PMC10820072 DOI: 10.3390/mi15010036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Revised: 12/16/2023] [Accepted: 12/21/2023] [Indexed: 01/24/2024]
Abstract
We report the magnetic-field-assisted electric-field-controlled domain switching of a magnetic single domain in a multiferroic/magnetoelectric Ni nanochevrons/[Pb(Mg1/3Nb2/3)O3]0.68-[PbTiO3]0.32 (PMN-PT) layered structure. Initially, a magnetic field was applied in the transverse direction across single-domain Ni nanochevrons to transform each of them into a two-domain state. Subsequently, an electric field was applied to the layered structure, exerting the converse magnetoelectric effect to transform/release the two-domain Ni nanochevrons into one of two possible single-domain states. Finally, the experimental results showed that approximately 50% of the single-domain Ni nanochevrons were switched permanently after applying our approach (i.e., the magnetization direction was permanently rotated by 180 degrees). These results mark important advancements for future nanoelectromagnetic systems.
Collapse
Affiliation(s)
- Chih-Cheng Cheng
- Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan; (C.-C.C.); (G.-P.L.)
- Electronic and Optoelectronic System Research Laboratories, Industrial Technology Research Institute, Hsinchu 310401, Taiwan
| | - Yu-Jen Chen
- Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan; (C.-C.C.); (G.-P.L.)
| | - Shin-Hung Lin
- Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan; (C.-C.C.); (G.-P.L.)
| | - Hsin-Min Wang
- Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan; (C.-C.C.); (G.-P.L.)
| | - Guang-Ping Lin
- Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan; (C.-C.C.); (G.-P.L.)
| | - Tien-Kan Chung
- Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan; (C.-C.C.); (G.-P.L.)
- International College of Semiconductor Technology, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
- Institute of Advanced Semiconductor, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
| |
Collapse
|
5
|
Chen K, Wang Z. A Micropillar Array Based Microfluidic Device for Rare Cell Detection and Single-Cell Proteomics. Methods Protoc 2023; 6:80. [PMID: 37736963 PMCID: PMC10514859 DOI: 10.3390/mps6050080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 08/25/2023] [Accepted: 08/31/2023] [Indexed: 09/23/2023] Open
Abstract
Advancements in single-cell-related technologies have opened new possibilities for analyzing rare cells, such as circulating tumor cells (CTCs) and rare immune cells. Among these techniques, single-cell proteomics, particularly single-cell mass spectrometric analysis (scMS), has gained significant attention due to its ability to directly measure transcripts without the need for specific reagents. However, the success of single-cell proteomics relies heavily on efficient sample preparation, as protein loss in low-concentration samples can profoundly impact the analysis. To address this challenge, an effective handling system for rare cells is essential for single-cell proteomic analysis. Herein, we propose a microfluidics-based method that offers highly efficient isolation, detection, and collection of rare cells (e.g., CTCs). The detailed fabrication process of the micropillar array-based microfluidic device is presented, along with its application for CTC isolation, identification, and collection for subsequent proteomic analysis.
Collapse
Affiliation(s)
- Kangfu Chen
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL 60208, USA;
- Chan Zuckerberg Biohub Chicago, Chicago, IL 60607, USA
| | - Zongjie Wang
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL 60208, USA;
- Chan Zuckerberg Biohub Chicago, Chicago, IL 60607, USA
| |
Collapse
|
6
|
Patel SK, Robertson DD, Cheema SS, Salahuddin S, Tolbert SH. In-Situ Measurement of Magnetoelectric Coupling and Strain Transfer in Multiferroic Nanocomposites of CoFe 2O 4 and Hf 0.5Zr 0.5O 2 with Residual Porosity. NANO LETTERS 2023; 23:3267-3273. [PMID: 37071064 DOI: 10.1021/acs.nanolett.3c00083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
With increasing applications for voltage-controlled magnetism, the need to more fully understand magnetoelectric coupling and strain transfer in nanostructured multiferroic composites has also increased. Here, multiferroic nanocomposites were synthesized using block copolymer templating to create mesoporous cobalt ferrite (CFO), followed by partly filling the pores with ferroelectric zirconium-substituted hafnia (HZO) using atomic layer deposition (ALD) to produce a porous multiferroic composite with enhanced mechanical flexibility. Upon electrical poling of the nanocomposite, we observed large changes in the magnetization. These changes partly relaxed upon removing the electric field, suggesting a strain-mediated mechanism. Both the anisotropic strain transfer from HZO to CFO and the strain relaxation after the field was removed were confirmed using high-resolution X-ray diffraction measurements collected during in-situ poling. The in-situ observation of both anisotropic strain transfer and large magnetization changes allows us to directly characterize the strong multiferroic coupling that can occur in flexible, nanostructured composites.
Collapse
Affiliation(s)
- Shreya K Patel
- Department of Chemistry and Biochemistry, University of California Los Angeles, Los Angeles, California 90095, United States
| | - Daniel D Robertson
- Department of Chemistry and Biochemistry, University of California Los Angeles, Los Angeles, California 90095, United States
| | - Suraj S Cheema
- Department of Electrical Engineering and Computer Sciences, University of California Berkeley, Berkeley, California 94720, United States
| | - Sayeef Salahuddin
- Department of Electrical Engineering and Computer Sciences, University of California Berkeley, Berkeley, California 94720, United States
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | - Sarah H Tolbert
- Department of Chemistry and Biochemistry, University of California Los Angeles, Los Angeles, California 90095, United States
- Department of Materials Science and Engineering, University of California Los Angeles, Los Angeles, California 90095, United States
- The California NanoSystems Institute, University of California Los Angeles, Los Angeles, California 90095, United States
| |
Collapse
|
7
|
Sun X, Li B, Li W, Ren X, Su N, Li R, Li J, Huang Q. A Resistance-Based Microfluidic Chip for Deterministic Single Cell Trapping Followed by Immunofluorescence Staining. MICROMACHINES 2022; 13:1272. [PMID: 36014194 PMCID: PMC9416254 DOI: 10.3390/mi13081272] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Revised: 07/31/2022] [Accepted: 08/04/2022] [Indexed: 06/15/2023]
Abstract
Microchips are fundamental tools for single-cell analysis. Although various microfluidic methods have been developed for single-cell trapping and analysis, most microchips cannot trap single cells deterministically for further analysis. In this paper, we describe a novel resistance-based microfluidic chip to implement deterministic single-cell trapping followed by immunofluorescence staining based on the least flow resistance principle. The design of a large circular structure before the constriction and the serpentine structure of the main channel made the flow resistance of the main channel higher than that of the trapping channel. Since cells preferred to follow paths with lower flow resistance, this design directed cells into the capture sites and improved single-cell trapping efficiency. We optimized the geometric parameters using numerical simulations. Experiments using A549 and K562 cell lines demonstrated the capability of our chip with (82.7 ± 2.4)% and (84 ± 3.3)% single-cell trapping efficiency, respectively. In addition, cells were immobilized at capture sites by applying the pulling forces at the outlet, which reduced the cell movement and loss and facilitated tracking of the cell in real time during the multistep immunofluorescence staining procedure. Due to the simple operation, high-efficiency single-cell trapping and lower cell loss, the proposed chip is expected to be a potential analytical platform for single tumor cell heterogeneity studies and clinical diagnosis.
Collapse
|
8
|
Zhang L, Liu B, Wang C, Xin C, Li R, Wang D, Xu L, Fan S, Zhang J, Zhang C, Hu Y, Li J, Wu D, Zhang L, Chu J. Functional Shape-Morphing Microarchitectures Fabricated by Dynamic Holographically Shifted Femtosecond Multifoci. NANO LETTERS 2022; 22:5277-5286. [PMID: 35728002 DOI: 10.1021/acs.nanolett.2c01178] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Functional microdevices based on responsive hydrogel show great promise in targeted delivery and biomedical analysis. Among state-of-the-art techniques for manufacturing hydrogel-based microarchitectures, femtosecond laser two-photon polymerization distinguishes itself by high designability and precision, but the point-by-point writing scheme requires mechanical apparatuses to support focus scanning. In this work, by predesigning holograms combined with lens phase modulation, multiple femtosecond laser spots are holographically generated and shifted for prototyping of three-dimensional shape-morphing structures without any moving equipment in the construction process. The microcage array is rapidly fabricated for high-performance target capturing enabled by switching environmental pH. Moreover, the built scaffolds can serve as arrayed analytical platforms for observing cell behaviors in normal or changeable living spaces or revealing the anticancer effects of loaded drugs. The proposed approach opens a new path for facile and flexible manufacturing of hydrogel-based functional microstructures with great versatility in micro-object manipulation.
Collapse
Affiliation(s)
- Leran Zhang
- Hefei National Laboratory for Physical Sciences at the Microscale and CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| | - Bingrui Liu
- Hefei National Laboratory for Physical Sciences at the Microscale and CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| | - Chaowei Wang
- Hefei National Laboratory for Physical Sciences at the Microscale and CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| | - Chen Xin
- Hefei National Laboratory for Physical Sciences at the Microscale and CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| | - Rui Li
- Hefei National Laboratory for Physical Sciences at the Microscale and CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| | - Dawei Wang
- Hefei National Laboratory for Physical Sciences at the Microscale and CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| | - Liqun Xu
- Hefei National Laboratory for Physical Sciences at the Microscale and CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| | - Shengying Fan
- Hefei National Laboratory for Physical Sciences at the Microscale and CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| | - Juan Zhang
- Hefei National Laboratory for Physical Sciences at the Microscale and CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| | - Chenchu Zhang
- Anhui Province Key Lab of Aerospace Structural Parts Forming Technology and Equipment, Institute of Industry and Equipment Technology, Hefei University of Technology, Hefei 230009, China
| | - Yanlei Hu
- Hefei National Laboratory for Physical Sciences at the Microscale and CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| | - Jiawen Li
- Hefei National Laboratory for Physical Sciences at the Microscale and CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| | - Dong Wu
- Hefei National Laboratory for Physical Sciences at the Microscale and CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| | - Li Zhang
- Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong 999077, China
| | - Jiaru Chu
- Hefei National Laboratory for Physical Sciences at the Microscale and CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China
| |
Collapse
|
9
|
Zhao X, Chen G, Zhou Y, Nashalian A, Xu J, Tat T, Song Y, Libanori A, Xu S, Li S, Chen J. Giant Magnetoelastic Effect Enabled Stretchable Sensor for Self-Powered Biomonitoring. ACS NANO 2022; 16:6013-6022. [PMID: 35417654 DOI: 10.1021/acsnano.1c11350] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Interfacing with the human body, wearable and implantable bioelectronics are a compelling platform technology for healthcare monitoring and medical therapeutics. However, clinical adoption of these devices is largely shadowed by their weakness in humidity resistance, stretchability, durability, and biocompatibility. In this work, we report a self-powered waterproof biomechanical sensor with stretchability up to 440% using the giant magnetoelastic effect in a soft polymer system. By manipulating the magnetic dipole alignment, the sensor achieved a particularly broad sensing range from 3.5 Pa to 2000 kPa, with a response time of ∼3 ms. To validate the excellent performance of the magnetoelastic sensor in biomonitoring, both ex vivo porcine heart testing and in vivo rat model testing were performed for cardiovascular monitoring and heart disease diagnosis. With the obtained sensing data, we have successfully detected ventricular arrhythmia and ventricular fibrillation in the Sprague-Dawley rat model. Holding a collection of compelling features, including minimal hysteresis, ultrawide sensing range, waterproofness, and biocompatibility, the magnetoelastic sensor represents a unique platform technology for self-powered biomonitoring in both wearable and implantable manners.
Collapse
Affiliation(s)
- Xun Zhao
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, United States
| | - Guorui Chen
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, United States
| | - Yihao Zhou
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, United States
| | - Ardo Nashalian
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, United States
| | - Jing Xu
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, United States
| | - Trinny Tat
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, United States
| | - Yang Song
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, United States
| | - Alberto Libanori
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, United States
| | - Shili Xu
- Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California 90095, United States
- Crump Institute for Molecular Imaging, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California 90095, United States
- Jonsson Comprehensive Cancer Center, University of California, Los Angeles, Los Angeles, California 90095, United States
| | - Song Li
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, United States
| | - Jun Chen
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, United States
| |
Collapse
|
10
|
Fallahi H, Cha H, Adelnia H, Dai Y, Ta HT, Yadav S, Zhang J, Nguyen NT. On-demand deterministic release of particles and cells using stretchable microfluidics. NANOSCALE HORIZONS 2022; 7:414-424. [PMID: 35237777 DOI: 10.1039/d1nh00679g] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Microfluidic technologies have been widely used for single-cell studies as they provide facile, cost-effective, and high-throughput evaluations of single cells with great accuracy. Capturing single cells has been investigated extensively using various microfluidic techniques. Furthermore, cell retrieval is crucial for the subsequent study of cells in applications such as drug screening. However, there are no robust methods for the facile release of the captured cells. Therefore, we developed a stretchable microfluidic cell trapper for easy on-demand release of cells in a deterministic manner. The stretchable microdevice consists of several U-shaped microstructures to capture single cells. The gap at the bottom edge of the microstructure broadens when the device is stretched along its width. By tuning the horizontal elongation of the device, ample space is provided to release particle/cell sizes of interest. The performance of the stretchable microdevice was evaluated using particles and cells. A deterministic release of particles was demonstrated using a mixture of 15 μm and 20 μm particles. The retrieval of the 15 μm particles and the 20 μm particles was achieved with elongation lengths of 1 mm and 5 mm, respectively. Two different cell lines, T47D breast cancer cells and J774A.1 macrophages, were employed to characterise the cell release capability of the device. The proposed stretchable micro cell trapper provided a deterministic recovery of the captured cells by adjusting the elongation length of the device. We believe that this stretchable microfluidic platform can provide an alternative method to facilely release trapped cells for subsequent evaluation.
Collapse
Affiliation(s)
- Hedieh Fallahi
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Haotian Cha
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Hossein Adelnia
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Yuchen Dai
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Hang Thu Ta
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Sharda Yadav
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Jun Zhang
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Nam-Trung Nguyen
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| |
Collapse
|