1
|
Yang Y, Yang Y, Hou Z, Wang T, Wu P, Shen L, Li P, Zhang K, Yang L, Sun S. Comprehensive review of materials, applications, and future innovations in biodegradable esophageal stents. Front Bioeng Biotechnol 2023; 11:1327517. [PMID: 38125305 PMCID: PMC10731276 DOI: 10.3389/fbioe.2023.1327517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 11/27/2023] [Indexed: 12/23/2023] Open
Abstract
Esophageal stricture (ES) results from benign and malignant conditions, such as uncontrolled gastroesophageal reflux disease (GERD) and esophageal neoplasms. Upper gastrointestinal endoscopy is the preferred diagnostic approach for ES and its underlying causes. Stent insertion using an endoscope is a prevalent method for alleviating or treating ES. Nevertheless, the widely used self-expandable metal stents (SEMS) and self-expandable plastic stents (SEPS) can result in complications such as migration and restenosis. Furthermore, they necessitate secondary extraction in cases of benign esophageal stricture (BES), rendering them unsatisfactory for clinical requirements. Over the past 3 decades, significant attention has been devoted to biodegradable materials, including synthetic polyester polymers and magnesium-based alloys, owing to their exceptional biocompatibility and biodegradability while addressing the challenges associated with recurring procedures after BES resolves. Novel esophageal stents have been developed and are undergoing experimental and clinical trials. Drug-eluting stents (DES) with drug-loading and drug-releasing capabilities are currently a research focal point, offering more efficient and precise ES treatments. Functional innovations have been investigated to optimize stent performance, including unidirectional drug-release and anti-migration features. Emerging manufacturing technologies such as three-dimensional (3D) printing and new biodegradable materials such as hydrogels have also contributed to the innovation of esophageal stents. The ultimate objective of the research and development of these materials is their clinical application in the treatment of ES and other benign conditions and the palliative treatment of malignant esophageal stricture (MES). This review aimed to offer a comprehensive overview of current biodegradable esophageal stent materials and their applications, highlight current research limitations and innovations, and offer insights into future development priorities and directions.
Collapse
Affiliation(s)
- Yaochen Yang
- Department of Gastroenterology, Endoscopic Center, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
- Research Center for Biomedical Materials, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Yuanyuan Yang
- Department of Gastroenterology, Endoscopic Center, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Zhipeng Hou
- Research Center for Biomedical Materials, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Tingting Wang
- Department of Gastroenterology, Endoscopic Center, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Peng Wu
- Department of Gastroenterology, Endoscopic Center, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Lufan Shen
- Department of Gastroenterology, Endoscopic Center, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Peng Li
- Liaoning Research Institute for Eugenic Birth and Fertility, China Medical University, Shenyang, China
| | - Kai Zhang
- Department of Gastroenterology, Endoscopic Center, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| | - Liqun Yang
- Research Center for Biomedical Materials, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
- Liaoning Research Institute for Eugenic Birth and Fertility, China Medical University, Shenyang, China
| | - Siyu Sun
- Department of Gastroenterology, Endoscopic Center, Engineering Research Center of Ministry of Education for Minimally Invasive Gastrointestinal Endoscopic Techniques, Shengjing Hospital of China Medical University, Shenyang, China
| |
Collapse
|
2
|
Vasileiadou AC, Karageorgos FF, Kiparissides C. Model-based Optimization of Drug Release Rate from a Size Distributed Population of Biodegradable Polymer Carriers. Eur J Pharm Biopharm 2023; 186:112-131. [PMID: 36870398 DOI: 10.1016/j.ejpb.2023.02.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 02/21/2023] [Accepted: 02/27/2023] [Indexed: 03/06/2023]
Abstract
In the present study, a comprehensive polymer degradation-drug diffusion model is developed to describe the polymer degradation kinetics and quantify the release rate of an active pharmaceutical ingredient (API) from a size-distributed population of drug-loaded poly(lactic-co-glycolic) acid (PLGA) carriers in terms of material and morphological properties of the drug carriers. To take into account the spatial-temporal variation of the drug and water diffusion coefficients, three new correlations are developed in terms of spatial-temporal variation of the molecular weight of the degrading polymer chains. The first one relates the diffusion coefficients with the time-spatial variation of the molecular weight of PLGA and initial drug loading and, the second one with the initial particle size, and the third one with evolution of the particle porosity due to polymer degradation. The derived model, comprising a system of partial differential and algebraic equations, is numerically solved using the method of lines and validated against published experimental data on the drug release rate from a size distributed population of piroxicam-PLGA microspheres. Finally, a multi-parametric optimization problem is formulated to calculate the optimal particle size and drug loading distributions of drug-loaded PLGA carriers to realize a desired zero-order drug release rate of a therapeutic drug over a specified administration period of several weeks. It is envisaged that the proposed model-based optimization approach will aid the optimal design of new controlled drug delivery systems and, consequently, the therapeutic outcome of an administered drug.
Collapse
Affiliation(s)
- Athina C Vasileiadou
- Department of Chemical Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Filippos F Karageorgos
- Department of Chemical Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Costas Kiparissides
- Department of Chemical Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; Chemical Process & Energy Resources Institute, Centre for Research and Technology Hellas, P.O. Box 60361, 57001 Thessaloniki, Greece.
| |
Collapse
|
3
|
Wu L, Seon GM, Ju S, Choi SH, Jiang ES, Kim Y, Chung SH, Ahn JS, Yang HC. Synergistic effects of arginine-glycine-aspartic acid and phosphatidylserine on the surface immunomodulation and osseointegration of titanium implants. Biomater Sci 2023; 11:1358-1372. [PMID: 36594560 DOI: 10.1039/d2bm01589g] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The control of macrophage polarization is important in bone tissue regeneration such as osseointegration. In this study, a coating method was developed to improve the osseointegration of titanium (Ti) implants by generating an immunomodulatory effect. The surface of the Ti discs was coated with a poly(lactide-co-glycolide)(PLGA) polymer, phosphatidylserine (PS), and arginine-glycine-aspartic acid (RGD) peptide conjugated phospholipid. In in vitro assay using mouse bone marrow-derived macrophages (BMDMs), the most significant expression of the M2 marker genes (Arg-1, YM-1, FIZZ1) and CD206, an M2 surface marker, was obtained with coatings containing 6 mol% RGD conjugates and phospholipids consisting of 50 mol% PS. The M2-inducing effect of RGD and PS was also verified in rat femurs where coated Ti rods were implanted. The RGD and PS coating significantly enhanced the osseointegration of the Ti implants. Moreover, a biomechanical push-out test showed that the RGD and PS coating increased the interfacial binding force between the bone and implants. These results indicate that PS and RGD can be applied to the solid surface of implantable biomedical devices to improve immunomodulation and tissue regeneration.
Collapse
Affiliation(s)
- Lele Wu
- Department of Dental Biomaterials Science, Dental Research Institute, School of Dentistry, Seoul National University, 101, Deahak-ro, Jongno-gu, Seoul 03080, South Korea.
| | - Gyeung Mi Seon
- Department of Dental Biomaterials Science, Dental Research Institute, School of Dentistry, Seoul National University, 101, Deahak-ro, Jongno-gu, Seoul 03080, South Korea.
| | - Sungwon Ju
- Department of Dental Biomaterials Science, Dental Research Institute, School of Dentistry, Seoul National University, 101, Deahak-ro, Jongno-gu, Seoul 03080, South Korea.
| | - Sang Hoon Choi
- Department of Dental Biomaterials Science, Dental Research Institute, School of Dentistry, Seoul National University, 101, Deahak-ro, Jongno-gu, Seoul 03080, South Korea.
| | - En-Shi Jiang
- Department of Dental Biomaterials Science, Dental Research Institute, School of Dentistry, Seoul National University, 101, Deahak-ro, Jongno-gu, Seoul 03080, South Korea.
| | - Yongjoon Kim
- Department of Dental Biomaterials Science, Dental Research Institute, School of Dentistry, Seoul National University, 101, Deahak-ro, Jongno-gu, Seoul 03080, South Korea.
| | - Shin Hye Chung
- Department of Dental Biomaterials Science, Dental Research Institute, School of Dentistry, Seoul National University, 101, Deahak-ro, Jongno-gu, Seoul 03080, South Korea.
| | - Jin-Soo Ahn
- Department of Dental Biomaterials Science, Dental Research Institute, School of Dentistry, Seoul National University, 101, Deahak-ro, Jongno-gu, Seoul 03080, South Korea.
| | - Hyeong-Cheol Yang
- Department of Dental Biomaterials Science, Dental Research Institute, School of Dentistry, Seoul National University, 101, Deahak-ro, Jongno-gu, Seoul 03080, South Korea.
| |
Collapse
|
4
|
Dou Z, Chen S, Wang J, Xia L, Maitz MF, Tu Q, Zhang W, Yang Z, Huang N. A "built-up" composite film with synergistic functionalities on Mg-2Zn-1Mn bioresorbable stents improves corrosion control effects and biocompatibility. Bioact Mater 2023; 25:223-238. [PMID: 36817823 PMCID: PMC9929524 DOI: 10.1016/j.bioactmat.2023.02.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 02/04/2023] [Accepted: 02/04/2023] [Indexed: 02/11/2023] Open
Abstract
Control of premature corrosion of magnesium (Mg) alloy bioresorbable stents (BRS) is frequently achieved by the addition of rare earth elements. However, limited long-term experience with these elements causes concerns for clinical application and alternative methods of corrosion control are sought after. Herein, we report a "built-up" composite film consisting of a bottom layer of MgF2 conversion coating, a sandwich layer of a poly (1, 3-trimethylene carbonate) (PTMC) and 3-aminopropyl triethoxysilane (APTES) co-spray coating (PA) and on top a layer of poly (lactic-co-glycolic acid) (PLGA) ultrasonic spray coating to decorate the rare earth element-free Mg-2Zn-1Mn (ZM21) BRS for tailoring both corrosion resistance and biological functions. The developed "built-up" composite film shows synergistic functionalities, allowing the compression and expansion of the coated ZM21 BRS on an angioplasty balloon without cracking or peeling. Of special importance is that the synergistic corrosion control effects of the "built-up" composite film allow for maintaining the mechanical integrity of stents for up to 3 months, where complete biodegradation and no foreign matter residue were observed about half a year after implantation in rabbit iliac arteries. Moreover, the functionalized ZM21 BRS accomplished re-endothelialization within one month.
Collapse
Affiliation(s)
- Zhenglong Dou
- Key Lab of Advanced Technology of Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Shuiling Chen
- Key Lab of Advanced Technology of Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Jiacheng Wang
- Key Lab of Advanced Technology of Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Li Xia
- Key Lab of Advanced Technology of Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Manfred F. Maitz
- Key Lab of Advanced Technology of Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
- Max Bergmann Center of Biomaterials Dresden, Leibniz Institute of Polymer Research Dresden, Hohe Strasse 6, 01069, Dresden, Germany
| | - Qiufen Tu
- Key Lab of Advanced Technology of Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
| | - Wentai Zhang
- Affiliated Dongguan Hospital, Southern Medical University, Dongguan, Guangdong, 523059, China
| | - Zhilu Yang
- Affiliated Dongguan Hospital, Southern Medical University, Dongguan, Guangdong, 523059, China
- Guangdong Provincial Key Laboratory of Cardiac Function and Microcirculation, Guangzhou, Guangdong, 510080, China
- Department of Cardiology, Third People's Hospital of Chengdu Affiliated to Southwest Jiaotong University, Chengdu, 610031, China
- Corresponding author. Affiliated Dongguan Hospital, Southern Medical University, Dongguan, Guangdong, 523059, China.
| | - Nan Huang
- Key Lab of Advanced Technology of Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
- Affiliated Dongguan Hospital, Southern Medical University, Dongguan, Guangdong, 523059, China
- Corresponding author. Affiliated Dongguan Hospital, Southern Medical University, Dongguan, Guangdong, 523059, China.
| |
Collapse
|
5
|
Efovi D, Xiao Q. Noncoding RNAs in Vascular Cell Biology and Restenosis. BIOLOGY 2022; 12:24. [PMID: 36671717 PMCID: PMC9855655 DOI: 10.3390/biology12010024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 12/17/2022] [Accepted: 12/20/2022] [Indexed: 12/25/2022]
Abstract
In-stent restenosis (ISR), characterised by ≥50% re-narrowing of the target vessel, is a common complication following stent implantation and remains a significant challenge to the long-term success of angioplasty procedures. Considering the global burden of cardiovascular diseases, improving angioplasty patient outcomes remains a key priority. Noncoding RNAs (ncRNAs) including microRNA (miRNA), long noncoding RNA (lncRNA) and circular RNA (circRNA) have been extensively implicated in vascular cell biology and ISR through multiple, both distinct and overlapping, mechanisms. Vascular smooth muscle cells, endothelial cells and macrophages constitute the main cell types involved in the multifactorial pathophysiology of ISR. The identification of critical regulators exemplified by ncRNAs in all these cell types and processes makes them an exciting therapeutic target in the field of restenosis. In this review, we will comprehensively explore the potential functions and underlying molecular mechanisms of ncRNAs in vascular cell biology in the context of restenosis, with an in-depth focus on vascular cell dysfunction during restenosis development and progression. We will also discuss the diagnostic biomarker and therapeutic target potential of ncRNAs in ISR. Finally, we will discuss the current shortcomings, challenges, and perspectives toward the clinical application of ncRNAs.
Collapse
Affiliation(s)
- Denis Efovi
- William Harvey Research Institute, Faculty of Medicine and Dentistry, Queen Mary University of London, London EC1M 6BQ, UK
| | - Qingzhong Xiao
- William Harvey Research Institute, Faculty of Medicine and Dentistry, Queen Mary University of London, London EC1M 6BQ, UK
- Key Laboratory of Cardiovascular Diseases, School of Basic Medical Sciences, Guangzhou Institute of Cardiovascular Disease, The Second Affiliated Hospital, Guangzhou Medical University, Guangzhou 511436, China
| |
Collapse
|
6
|
Li H, Chiang AWT, Lewis NE. Artificial intelligence in the analysis of glycosylation data. Biotechnol Adv 2022; 60:108008. [PMID: 35738510 DOI: 10.1016/j.biotechadv.2022.108008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Revised: 06/15/2022] [Accepted: 06/16/2022] [Indexed: 11/18/2022]
Abstract
Glycans are complex, yet ubiquitous across biological systems. They are involved in diverse essential organismal functions. Aberrant glycosylation may lead to disease development, such as cancer, autoimmune diseases, and inflammatory diseases. Glycans, both normal and aberrant, are synthesized using extensive glycosylation machinery, and understanding this machinery can provide invaluable insights for diagnosis, prognosis, and treatment of various diseases. Increasing amounts of glycomics data are being generated thanks to advances in glycoanalytics technologies, but to maximize the value of such data, innovations are needed for analyzing and interpreting large-scale glycomics data. Artificial intelligence (AI) provides a powerful analysis toolbox in many scientific fields, and here we review state-of-the-art AI approaches on glycosylation analysis. We further discuss how models can be analyzed to gain mechanistic insights into glycosylation machinery and how the machinery shapes glycans under different scenarios. Finally, we propose how to leverage the gained knowledge for developing predictive AI-based models of glycosylation. Thus, guiding future research of AI-based glycosylation model development will provide valuable insights into glycosylation and glycan machinery.
Collapse
Affiliation(s)
- Haining Li
- Department of Bioengineering, University of California, San Diego, La Jolla, CA 92093, USA
| | - Austin W T Chiang
- Department of Pediatrics, University of California, San Diego, La Jolla, CA 92093, USA.
| | - Nathan E Lewis
- Department of Bioengineering, University of California, San Diego, La Jolla, CA 92093, USA; Department of Pediatrics, University of California, San Diego, La Jolla, CA 92093, USA.
| |
Collapse
|
7
|
Sarmadi M, Ta C, VanLonkhuyzen AM, De Fiesta DC, Kanelli M, Sadeghi I, Behrens AM, Ingalls B, Menon N, Daristotle JL, Yu J, Langer R, Jaklenec A. Experimental and computational understanding of pulsatile release mechanism from biodegradable core-shell microparticles. SCIENCE ADVANCES 2022; 8:eabn5315. [PMID: 35857507 PMCID: PMC9278852 DOI: 10.1126/sciadv.abn5315] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Accepted: 05/28/2022] [Indexed: 05/11/2023]
Abstract
Next-generation therapeutics require advanced drug delivery platforms with precise control over morphology and release kinetics. A recently developed microfabrication technique enables fabrication of a new class of injectable microparticles with a hollow core-shell structure that displays pulsatile release kinetics, providing such capabilities. Here, we study this technology and the resulting core-shell microstructures. We demonstrated that pulsatile release is governed by a sudden increase in porosity of the polymeric matrix, leading to the formation of a porous path connecting the core to the environment. Moreover, the release kinetics within the range studied remained primarily independent of the particle geometry but highly dependent on its composition. A qualitative technique was developed to study the pattern of pH evolution in the particles. A computational model successfully modeled deformations, indicating sudden expansion of the particle before onset of release. Results of this study contribute to the understanding and design of advanced drug delivery systems.
Collapse
Affiliation(s)
- Morteza Sarmadi
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Harvard-MIT Division of Health Sciences and Technology, Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Christina Ta
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Abigail M. VanLonkhuyzen
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Dominique C. De Fiesta
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Maria Kanelli
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Ilin Sadeghi
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Adam M. Behrens
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Bailey Ingalls
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Harvard-MIT Division of Health Sciences and Technology, Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Nandita Menon
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - John L. Daristotle
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Julie Yu
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Robert Langer
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Harvard-MIT Division of Health Sciences and Technology, Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Ana Jaklenec
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| |
Collapse
|
8
|
Abbasnezhad N, Zirak N, Champmartin S, Shirinbayan M, Bakir F. An Overview of In Vitro Drug Release Methods for Drug-Eluting Stents. Polymers (Basel) 2022; 14:2751. [PMID: 35808798 PMCID: PMC9269075 DOI: 10.3390/polym14132751] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 06/15/2022] [Accepted: 06/16/2022] [Indexed: 01/08/2023] Open
Abstract
The drug release profile of drug-eluting stents (DESs) is affected by a number of factors, including the formulation, design, and physicochemical properties of the utilized material. DES has been around for twenty years and despite its widespread clinical use, and efficacy in lowering the rate of target lesion restenosis, it still requires additional development to reduce side effects and provide long-term clinical stability. Unfortunately, for analyzing these implants, there is still no globally accepted in vitro test method. This is owing to the stent's complexity as well as the dynamic arterial compartments of the blood and vascular wall. The former is the source of numerous biological, chemical, and physical mechanisms that are more commonly observed in tissue, lumen, and DES. As a result, universalizing bio-relevant apparatus, suitable for liberation testing of such complex implants is difficult. This article aims to provide a comprehensive review of the methods used for in vitro release testing of DESs. Aspects related to the correlation of the release profiles in the cases of in vitro and in vivo are also addressed.
Collapse
Affiliation(s)
- Navideh Abbasnezhad
- Arts et Métiers Institute of Technology, CNAM, LIFSE, HESAM University, F-75013 Paris, France; (N.Z.); (S.C.)
- Arts et Métiers Institute of Technology, CNAM, PIMM, HESAM University, F-75013 Paris, France;
| | - Nader Zirak
- Arts et Métiers Institute of Technology, CNAM, LIFSE, HESAM University, F-75013 Paris, France; (N.Z.); (S.C.)
- Arts et Métiers Institute of Technology, CNAM, PIMM, HESAM University, F-75013 Paris, France;
| | - Stéphane Champmartin
- Arts et Métiers Institute of Technology, CNAM, LIFSE, HESAM University, F-75013 Paris, France; (N.Z.); (S.C.)
| | - Mohammadali Shirinbayan
- Arts et Métiers Institute of Technology, CNAM, PIMM, HESAM University, F-75013 Paris, France;
| | - Farid Bakir
- Arts et Métiers Institute of Technology, CNAM, LIFSE, HESAM University, F-75013 Paris, France; (N.Z.); (S.C.)
| |
Collapse
|
9
|
Abstract
Carriers are protective transporters of drugs to target cells, facilitating therapy under each points of view, such as fast healing, reducing infective phenomena, and curing illnesses while avoiding side effects. Over the last 60 years, several scientists have studied drug carrier properties, trying to adapt them to the release environment. Drug/Carrier interaction phenomena have been deeply studied, and the release kinetics have been modeled according to the occurring phenomena involved in the system. It is not easy to define models’ advantages and disadvantages, since each of them may fit in a specific situation, considering material interactions, diffusion and erosion phenomena, and, no less important, the behavior of receiving medium. This work represents a critical review on main mathematical models concerning their dependency on physical, chemical, empirical, or semi-empirical variables. A quantitative representation of release profiles has been shown for the most representative models. A final critical comment on the applicability of these models has been presented at the end. A mathematical approach to this topic may help students and researchers approach the wide panorama of models that exist in literature and have been optimized over time. This models list could be of practical inspiration for the development of researchers’ own new models or for the application of proper modifications, with the introduction of new variable dependency.
Collapse
|
10
|
Sirolimus Release from Biodegradable Polymers for Coronary Stent Application: A Review. Pharmaceutics 2022; 14:pharmaceutics14030492. [PMID: 35335869 PMCID: PMC8949664 DOI: 10.3390/pharmaceutics14030492] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 02/21/2022] [Accepted: 02/23/2022] [Indexed: 02/02/2023] Open
Abstract
Drug-eluting stents (DESs) are commonly used for the treatment of coronary artery disease. The evolution of the drug-eluting layer on the surface of the metal stent plays an important role in DES functionality. Here, the use of biodegradable polymers has emerged as an attractive strategy because it minimizes the occurrence of late thrombosis after stent implantation. Furthermore, understanding the drug-release behavior of DESs is also important for improving the safety and efficacy of stent treatments. Drug release from biodegradable polymers has attracted extensive research attention because biodegradable polymers with different properties show different drug-release behaviors. Molecular weight, composition, glass transition temperature, crystallinity, and the degradation rate are important properties affecting the behavior of polymers. Sirolimus is a conventional anti-proliferation drug and is the most widely used drug in DESs. Sirolimus-release behavior affects endothelialization and thrombosis formation after DES implantation. In this review, we focus on sirolimus release from biodegradable polymers, including synthetic and natural polymers widely used in the medical field. We hope this review will provide valuable up-to-date information on this subject and contribute to the further development of safe and efficient DESs.
Collapse
|
11
|
Pleouras DS, Karanasiou GS, Loukas VS, Semertzioglou A, Moulas AN, Fotiadis DI. Investigation of the drug release time from the biodegrading coating of an everolimus eluting stent. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:1698-1701. [PMID: 34891613 DOI: 10.1109/embc46164.2021.9629813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
This case-study examines the release time of the everolimus drug from an experimental biodegrading coating of a Rontis corp. drug eluting stent (DES). The controlled drug release is achieved by the degradation of the coating, which consists of a mixture of polylactic co-glycolic acid (PLGA) and everolimus (55:45). In our analysis, we used the outcome of another study, which contains the geometry of an in-silico deployed Rontis corp. stent in a 3D reconstructed coney arterial segment. Using this geometry as input, the everolimus release was simulated using a computational model that includes: i) modeling of the blood flow dynamics, ii) modeling of PLGA degradation, and iii) modeling of the everolimus advection and diffusion towards both the lumen and the arterial wall. The results show the rapid release of everolimus. This is justified due to the high porosity of the coating, which is caused by the initial high concentration of everolimus in the coating.Clinical Relevance - The methodology presented in this work is an additional step towards predicting accurately drug release from DES. Also, the results of our work prove that high drug concentration in the coating causes its rapid release, which could be used as input in the design of new DES.
Collapse
|
12
|
SARIFUDDIN, ALSEMIRY REIMAD, MANDAL PRASHANTAKUMAR. EFFECTS OF COATING PROPERTIES ON CONTROLLED DELIVERY FROM AN EMBEDDED DRUG-ELUTING STENT: A SIMULATION STUDY. J BIOL SYST 2021. [DOI: 10.1142/s0218339021500145] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The present investigation deals with the effects of biodegradable, biodurable and polymer-free coating of a stent on the release mechanism of the drug in a porous medium. The Brinkman equations for the interstitial fluid, the unsteady convection-diffusion-reaction equation for the transport of free drug in the tissue and the unsteady reaction equations for the bound as well as the internalized drug have been considered. In the coating, the transport of drug has been modeled as a diffusion process. Effects of different percentages of the embedment, convection and various coating properties of the stent on the transport of free drug, its retention and the internalization of the bound drug have been studied. Immersed Boundary Method (IBM) in the staggered grid formulation (IBM-MAC) has been used to tackle numerically the system of nonlinear governing equations. Simulated results predict the fastest release of drug from a biodegradable coating, but the averaged concentrations of all drug forms do reach a quasi-steady state in case of a biodurable coating irrespective of the degrees of embedment. Moreover, for all embedment levels of the stent, a biodegradable coating is superior to that of biodurable and polymer-free coating in the presence/absence of convection for larger times, but this superiority is lost for smaller times. Unlike biodurable coating, it is also predicted that the more the embedment level does not necessarily imply the more the effectiveness of delivery for biodegradable and polymer-free coatings of a stent.
Collapse
Affiliation(s)
- SARIFUDDIN
- Department of Mathematics, Berhampore College, P.O.-Berhampore, Dist.-Murshidabad, WB 742101, India
| | - REIMA D. ALSEMIRY
- Department of Mathematics, Faculty of Science, Taibah University, P.O. Box 89, Yanbu 41911, Saudi Arabia
- Department of Mathematical Sciences, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
| | | |
Collapse
|
13
|
Geetha Devi M, Dutta S, Al Hinai AT, Feroz S. Nano engineered biodegradable capsules for the encapsulation and kinetic release studies of ciprofloxacin hydrochloride. J INDIAN CHEM SOC 2021. [DOI: 10.1016/j.jics.2021.100109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
14
|
Song J, Kouidri S, Bakir F. Review on the numerical investigations of mass transfer from drug eluting stent. Biocybern Biomed Eng 2021. [DOI: 10.1016/j.bbe.2021.06.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
15
|
Heparin-Tagged PLA-PEG Copolymer-Encapsulated Biochanin A-Loaded (Mg/Al) LDH Nanoparticles Recommended for Non-Thrombogenic and Anti-Proliferative Stent Coating. Int J Mol Sci 2021; 22:ijms22115433. [PMID: 34063962 PMCID: PMC8196732 DOI: 10.3390/ijms22115433] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 04/26/2021] [Accepted: 05/17/2021] [Indexed: 12/29/2022] Open
Abstract
Drug-eluting stents have been widely implanted to prevent neointimal hyperplasia associated with bare metal stents. Conventional polymers and anti-proliferative drugs suffer from stent thrombosis due to the non-selective nature of the drugs and hypersensitivity to polymer degradation products. Alternatively, various herbal anti-proliferative agents are sought, of which biochanin A (an isoflavone phytoestrogen) was known to have anti-proliferative and vasculoprotective action. PLA-PEG diblock copolymer was tagged with heparin, whose degradation releases heparin locally and prevents thrombosis. To get a controlled drug release, biochanin A was loaded in layered double hydroxide nanoparticles (LDH), which are further encapsulated in a heparin-tagged PLA-PEG copolymer. LDH nanoparticles are synthesized by a co-precipitation process; in situ as well as ex situ loading of biochanin A were done. PLA-PEG-heparin copolymer was synthesized by esterification reaction, and the drug-loaded nanoparticles are coated. The formulation was characterized by FTIR, XRD, DSC, DLS, and TEM. In vitro drug release studies, protein adhesion, wettability, hemocompatibility, and degradation studies were performed. The drug release was modeled by mathematical models to further emphasize the mechanism of drug release. The developed drug-eluting stent coating is non-thrombogenic, and it offers close to zero-order release for 40 days, with complete polymer degradation in 14 weeks.
Collapse
|
16
|
New Insight into the Mechanism of Drug Release from Poly(d,l-lactide) Film by Electron Paramagnetic Resonance. Polymers (Basel) 2020; 12:polym12123046. [PMID: 33353203 PMCID: PMC7767321 DOI: 10.3390/polym12123046] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Revised: 12/14/2020] [Accepted: 12/14/2020] [Indexed: 12/31/2022] Open
Abstract
A novel approach based on convolution of the electron paramagnetic resonance (EPR) spectra was used for quantitative study of the release kinetics of paramagnetic dopants from poly(d,l-lactide) films. A non-monotonic dependence of the release rate on time was reliably recorded. The release regularities were compared with the dynamics of polymer structure changes determined by EPR, SEM, and optic microscopy. The data obtained allow for the conclusion that the main factor governing dopant release is the formation of pores connected with the surface. In contrast, the contribution of the dopant diffusion through the polymer matrix is negligible. The dopant release can be divided into two phases: release through surface pores, which are partially closed with time, and release through pores initially formed inside the polymer matrix due to autocatalytic hydrolysis of the polymer and gradually connected to the surface of the sample. For some time, these processes co-occur. The mathematical model of the release kinetics based on pore formation is presented, describing the kinetics of release of various dopants from the polymer films of different thicknesses.
Collapse
|
17
|
Xiao P, Qi P, Chen J, Song Z, Wang Y, He H, Tang X, Wang P. The effect of polymer blends on initial release regulation and in vitro-in vivo relationship of peptides loaded PLGA-Hydrogel Microspheres. Int J Pharm 2020; 591:119964. [PMID: 33137449 DOI: 10.1016/j.ijpharm.2020.119964] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2020] [Revised: 09/22/2020] [Accepted: 10/06/2020] [Indexed: 12/22/2022]
Abstract
The aim of this study was to resolve the lag time problem for peptides loaded PLGA-Hydrogel Microspheres (PLGA-gel-Ms) by blending low molecular PLGA (Mw. 1 kDa) into PLGA (Mw. 10 kDa) as an intrinsic porogen, and then assess the in vitro-in vivo relationship (IVIVR). Here, Goserelin acetate (GOS) was chosen as the model peptides. When compared to additional types of porogen, the intrinsic porogen avoided impurities remaining and protected the bioactivities of the peptides. By adding 10% PLGA (Mw. 1 kDa), the lag time was eliminated both in vitro and in vivo with a desirable EE (97.04% ± 0.51%). The release mechanisms were found to be: a) initial GOS release mainly controlled by pores diffusion and b) autocatalysis of PLGA (Mw. 1 kDa) which increased the quantity of aqueous pores, as revealed by SEM images. To solve the challenges caused by multiphasic release profiles, for the first time the Segmented phases IVIVR were proposed and developed, and showed improved linear fitting effects and supported the proposed release mechanisms. The application of PLGA blends could provide a new insight into PLGA microsphere initial release rate regulation.
Collapse
Affiliation(s)
- Peifu Xiao
- Department of Pharmacy, The First Affiliated Hospital of China Medical University, Shenyang 110001, Liaoning, People's Republic of China; Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Wenhua Road 103, Shenyang 110016, Liaoning, People's Republic of China
| | - Pan Qi
- Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Wenhua Road 103, Shenyang 110016, Liaoning, People's Republic of China
| | - Jin Chen
- Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Wenhua Road 103, Shenyang 110016, Liaoning, People's Republic of China
| | - Zilin Song
- Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Wenhua Road 103, Shenyang 110016, Liaoning, People's Republic of China
| | - Yidan Wang
- Department of Pharmacy, The First Affiliated Hospital of China Medical University, Shenyang 110001, Liaoning, People's Republic of China
| | - Haibing He
- Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Wenhua Road 103, Shenyang 110016, Liaoning, People's Republic of China
| | - Xing Tang
- Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Wenhua Road 103, Shenyang 110016, Liaoning, People's Republic of China
| | - Puxiu Wang
- Department of Pharmacy, The First Affiliated Hospital of China Medical University, Shenyang 110001, Liaoning, People's Republic of China.
| |
Collapse
|
18
|
Ho MH, Claudia JC, Tai WC, Huang KY, Lai CH, Chang CH, Chang YC, Wu YC, Kuo MYP, Chang PC. The treatment response of barrier membrane with amoxicillin-loaded nanofibers in experimental periodontitis. J Periodontol 2020; 92:886-895. [PMID: 32996124 DOI: 10.1002/jper.20-0256] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 08/11/2020] [Accepted: 09/13/2020] [Indexed: 11/09/2022]
Abstract
BACKGROUND Infection control is a major determinant of guided tissue regeneration (GTR). This study aims to develop an antibiotic-loaded membrane to assist periodontal repair. METHODS Poly(D,L-lactic acid) (PDLLA) nanofibers encapsulating amoxicillin (PDLLA-AMX) were fabricated using the electrospinning technique, and their structures, drug encapsulation efficiency, and release characteristics were assessed. The viability and behaviors of periodontal ligament (PDL) cells on nanofibers, and antibacterial capabilities of nanofibers were evaluated in vitro. Early therapeutic efficiency of the antibiotic-loaded membranes was investigated in rats with ligature-induced experimental periodontitis, and the outcomes were evaluated by gene expression, microcomputed tomography imaging, and histology within 7 days of membrane placement. RESULTS AMX was successfully encapsulated in the PDLLA nanofibers and released in a sustained manner. After initial attachment was achieved, cells stretched out along with the directions of nanofibers. The viability and expression of migration-associated gene of PDL cells were significantly improved, and the growth of Streptococcus sanguinis and Porphyromonas gingivalis was significantly reduced in the PDLLA-AMX group compared with the controls. On PDLLA-AMX-treated sites, wound dehiscence and sulcular inflammation were reduced. Collagen fiber matrix deposition was accelerated with upregulated type I collagen and interleukin-1β, and downregulated matrix metalloproteinase-8, whereas periodontal bone level and the expressions of vascular endothelial growth factor and core-binding factor subunit alpha-1 were equivalent to conventional membrane treatment. CONCLUSIONS PDLLA-AMX nanofibers inhibited bacterial growth and promoted the viability and mobility of PDL cells after initial cell attachment. Membranes with PDLLA-AMX nanofibers reduced inflammation and accelerated periodontal repair at an early stage, providing good prospects for the further development of GTR membranes.
Collapse
Affiliation(s)
- Ming-Hua Ho
- Department of Chemical Engineering, College of Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
| | - Jeannete Cindy Claudia
- Department of Chemical Engineering, College of Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
| | - Wei-Chiu Tai
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University, Taipei, Taiwan
| | - Kuan-Yu Huang
- Department of Chemical Engineering, College of Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
| | - Chern-Hsiung Lai
- College of Life Science, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Ching-He Chang
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University, Taipei, Taiwan
| | - Ying-Chieh Chang
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University, Taipei, Taiwan
| | - Yu-Chang Wu
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University, Taipei, Taiwan
| | - Mark Yen-Ping Kuo
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University, Taipei, Taiwan.,Division of Periodontics, Department of Dentistry, National Taiwan University Hospital, Taipei, Taiwan
| | - Po-Chun Chang
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University, Taipei, Taiwan.,Division of Periodontics, Department of Dentistry, National Taiwan University Hospital, Taipei, Taiwan.,School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| |
Collapse
|
19
|
Milosevic M, Stojanovic DB, Simic V, Grkovic M, Bjelovic M, Uskokovic PS, Kojic M. Preparation and modeling of three-layered PCL/PLGA/PCL fibrous scaffolds for prolonged drug release. Sci Rep 2020; 10:11126. [PMID: 32636450 PMCID: PMC7341868 DOI: 10.1038/s41598-020-68117-9] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Accepted: 06/10/2020] [Indexed: 12/27/2022] Open
Abstract
The authors present the preparation procedure and a computational model of a three‐layered fibrous scaffold for prolonged drug release. The scaffold, produced by emulsion/sequential electrospinning, consists of a poly(d,l-lactic-co-glycolic acid) (PLGA) fiber layer sandwiched between two poly(ε-caprolactone) (PCL) layers. Experimental results of drug release rates from the scaffold are compared with the results of the recently introduced computational finite element (FE) models for diffusive drug release from nanofibers to the three-dimensional (3D) surrounding medium. Two different FE models are used: (1) a 3D discretized continuum and fibers represented by a simple radial one-dimensional (1D) finite elements, and (2) a 3D continuum discretized by composite smeared finite elements (CSFEs) containing the fiber smeared and surrounding domains. Both models include the effects of polymer degradation and hydrophobicity (as partitioning) of the drug at the fiber/surrounding interface. The CSFE model includes a volumetric fraction of fibers and diameter distribution, and is additionally enhanced by using correction function to improve the accuracy of the model. The computational results are validated on Rhodamine B (fluorescent drug l) and other hydrophilic drugs. Agreement with experimental results proves that numerical models can serve as efficient tools for drug release to the surrounding porous medium or biological tissue. It is demonstrated that the introduced three-layered scaffold delays the drug release process and can be used for the time-controlled release of drugs in postoperative therapy.
Collapse
Affiliation(s)
- Miljan Milosevic
- Bioengineering Research and Development Center BioIRC Kragujevac, Prvoslava Stojanovica 6, Kragujevac, 34000, Serbia.,Belgrade Metropolitan University, Tadeusa Koscuska 63, Belgrade, 11000, Serbia
| | - Dusica B Stojanovic
- Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, Belgrade, 11000, Serbia
| | - Vladimir Simic
- Bioengineering Research and Development Center BioIRC Kragujevac, Prvoslava Stojanovica 6, Kragujevac, 34000, Serbia
| | - Mirjana Grkovic
- Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, Belgrade, 11000, Serbia
| | - Milos Bjelovic
- Department for Minimally Invasive Upper Digestive Surgery, Clinical Center of Serbia, Hospital for Digestive Surgery - First Surgical Hospital, Dr Koste Todorovica 66, Belgrade, 11000, Serbia
| | - Petar S Uskokovic
- Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, Belgrade, 11000, Serbia
| | - Milos Kojic
- Bioengineering Research and Development Center BioIRC Kragujevac, Prvoslava Stojanovica 6, Kragujevac, 34000, Serbia. .,The Department of Nanomedicine, Houston Methodist Research Institute, 6670 Bertner Ave., R7 117, Houston, TX, 77030, USA. .,Serbian Academy of Sciences and Arts, Knez Mihailova 35, Belgrade, 11000, Serbia.
| |
Collapse
|
20
|
Hering I, Eilebrecht E, Parnham MJ, Günday-Türeli N, Türeli AE, Weiler M, Schäfers C, Fenske M, Wacker MG. Evaluation of potential environmental toxicity of polymeric nanomaterials and surfactants. ENVIRONMENTAL TOXICOLOGY AND PHARMACOLOGY 2020; 76:103353. [PMID: 32086102 DOI: 10.1016/j.etap.2020.103353] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2019] [Accepted: 02/05/2020] [Indexed: 05/25/2023]
Abstract
Nanomaterials have gained huge importance in various fields including nanomedicine. Nanoformulations of drugs and nanocarriers are used to increase pharmaceutical potency. However, it was seen that polymeric nanomaterials can cause negative effects. Thus, it is essential to identify nanomaterials with the least adverse effects on aquatic organisms. To determine the toxicity of polymeric nanomaterials, we investigated the effects of poly(lactic-co-glycolid) acid (PLGA), Eudragit® E 100 and hydroxylpropyl methylcellulose phthalate (HPMCP) on zebrafish embryos using the fish embryo toxicity test (FET). Furthermore, we studied Cremophor® RH40, Cremophor® A25, Pluronic® F127 and Pluronic® F68 applied in the generation of nanoformulations to identify the surfactant with minimal toxic impact. The order of ecotoxicty was HPMCP < PLGA < Eudragit® E100 and Pluronic® F68 < Pluronic® F127 < Cremophor® RH40 < Cremophor® A25. In summary, HPMCP and Pluronic® F68 displayed the least toxic impact, thus suggesting adequate environmental compatibility for the generation of nanomedicines.
Collapse
Affiliation(s)
- Indra Hering
- Fraunhofer-Institut für Molekularbiologie und Angewandte Oekologie IME, 65926, Frankfurt, Main, Germany; Fraunhofer Institut für Molekularbiologie und Angewandte Oekologie IME, 57392, Schmallenberg, Germany; Goethe University Frankfurt am Main, Department Aquatic Ecotoxicology, Max-von-Laue-Str. 13, 60438 Frankfurt am Main, Germany.
| | - Elke Eilebrecht
- Fraunhofer Institut für Molekularbiologie und Angewandte Oekologie IME, 57392, Schmallenberg, Germany
| | - Michael J Parnham
- Fraunhofer-Institut für Molekularbiologie und Angewandte Oekologie IME, 65926, Frankfurt, Main, Germany
| | | | | | - Marc Weiler
- MJR, PharmJet GmbH, 66802, Überherrn, Germany
| | - Christoph Schäfers
- Fraunhofer Institut für Molekularbiologie und Angewandte Oekologie IME, 57392, Schmallenberg, Germany
| | - Martina Fenske
- Fraunhofer-Institut für Molekularbiologie und Angewandte Oekologie IME, 65926, Frankfurt, Main, Germany.
| | - Matthias G Wacker
- National University of Singapore, Department of Pharmacy, Faculty of Science, 6 Science Drive 2, Singapore, 117546, Singapore
| |
Collapse
|
21
|
Escuer J, Cebollero M, Peña E, McGinty S, Martínez MA. How does stent expansion alter drug transport properties of the arterial wall? J Mech Behav Biomed Mater 2020; 104:103610. [DOI: 10.1016/j.jmbbm.2019.103610] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Revised: 12/23/2019] [Accepted: 12/29/2019] [Indexed: 11/28/2022]
|
22
|
Ali MY, Tariq I, Farhan Sohail M, Amin MU, Ali S, Pinnapireddy SR, Ali A, Schäfer J, Bakowsky U. Selective anti-ErbB3 aptamer modified sorafenib microparticles: In vitro and in vivo toxicity assessment. Eur J Pharm Biopharm 2019; 145:42-53. [DOI: 10.1016/j.ejpb.2019.10.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 10/11/2019] [Accepted: 10/14/2019] [Indexed: 01/10/2023]
|
23
|
Radfar N, Mobedi H, Behnamghader A, Mashak A. PLGA‐based
in situ
‐forming system: degradation behavior in the presence of hydroxyapatite nanoparticles. POLYM ENG SCI 2019. [DOI: 10.1002/pen.25059] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Affiliation(s)
- Neda Radfar
- Department of Biomedical Engineering, Science and Research BranchIslamic Azad University Tehran Iran
| | - Hamid Mobedi
- Department of Novel Drug Delivery SystemsIran Polymer and Petrochemical Institute, P.O. Box: 14965/115 Tehran Iran
| | - Aliasghar Behnamghader
- Biomaterials Group, Nanotechnology and Advanced Materials DepartmentMaterials and Energy Research Center Karaj Iran
| | - Arezou Mashak
- Department of Novel Drug Delivery SystemsIran Polymer and Petrochemical Institute, P.O. Box: 14965/115 Tehran Iran
| |
Collapse
|
24
|
Zhu Y, Zhang H, Zhang Y, Wu H, Wei L, Zhou G, Zhang Y, Deng L, Cheng Y, Li M, Santos HA, Cui W. Endovascular Metal Devices for the Treatment of Cerebrovascular Diseases. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2019; 31:e1805452. [PMID: 30589125 DOI: 10.1002/adma.201805452] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 09/20/2018] [Indexed: 06/09/2023]
Abstract
Cerebrovascular disease involves various medical disorders that obstruct brain blood vessels or deteriorate cerebral circulation, resulting in ischemic or hemorrhagic stroke. Nowadays, platinum coils with or without biological modification have become routine embolization devices to reduce the risk of cerebral aneurysm bleeding. Additionally, many intracranial stents, flow diverters, and stent retrievers have been invented with uniquely designed structures. To accelerate the translation of these devices into clinical usage, an in-depth understanding of the mechanical and material performance of these metal-based devices is critical. However, considering the more distal location and tortuous anatomic characteristics of cerebral arteries, present devices still risk failing to arrive at target lesions. Consequently, more flexible endovascular devices and novel designs are under urgent demand to overcome the deficiencies of existing devices. Herein, the pros and cons of the current structural designs are discussed when these devices are applied to the treatment of diseases ranging broadly from hemorrhages to ischemic strokes, in order to encourage further development of such kind of devices and investigation of their use in the clinic. Moreover, novel biodegradable materials and drug elution techniques, and the design, safety, and efficacy of personalized devices for further clinical applications in cerebral vasculature are discussed.
Collapse
Affiliation(s)
- Yueqi Zhu
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai, 200233, P. R. China
| | - Hongbo Zhang
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, P. R. China
- Department of Pharmaceutical Sciences Laboratory, Åbo Akademi University, Turku, FI-20520, Finland
- Turku Center for Biotechnology, University of Turku and Åbo Akademi University, Turku, FI-20520, Finland
| | - Yiran Zhang
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai, 200233, P. R. China
| | - Huayin Wu
- Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, 02138, USA
| | - Liming Wei
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai, 200233, P. R. China
| | - Gen Zhou
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai, 200233, P. R. China
| | - Yuezhou Zhang
- Department of Pharmaceutical Sciences Laboratory, Åbo Akademi University, Turku, FI-20520, Finland
- Turku Center for Biotechnology, University of Turku and Åbo Akademi University, Turku, FI-20520, Finland
| | - Lianfu Deng
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, P. R. China
| | - Yingsheng Cheng
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai, 200233, P. R. China
| | - Minghua Li
- Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Shanghai, 200233, P. R. China
| | - Hélder A Santos
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, FI-00014, Helsinki, Finland
- Helsinki Institute of Life Science, University of Helsinki, FI-00014, Helsinki, Finland
| | - Wenguo Cui
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, P. R. China
| |
Collapse
|
25
|
Shen M, Almallahi R, Rizvi Z, Gonzalez-Martinez E, Yang G, Robertson ML. Accelerated hydrolytic degradation of ester-containing biobased epoxy resins. Polym Chem 2019. [DOI: 10.1039/c9py00240e] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Biobased epoxy resins, derived from lignin, phenolic acids, and vegetable oils, exhibited rapid degradation through hydrolysis in basic solution.
Collapse
Affiliation(s)
- Minjie Shen
- Department of Chemical and Biomolecular Engineering
- University of Houston
- Houston
- USA
| | - Rawan Almallahi
- Department of Chemical and Biomolecular Engineering
- University of Houston
- Houston
- USA
| | - Zeshan Rizvi
- Department of Chemical and Biomolecular Engineering
- University of Houston
- Houston
- USA
- Houston Community College
| | - Eliud Gonzalez-Martinez
- Department of Chemical and Biomolecular Engineering
- University of Houston
- Houston
- USA
- Houston Community College
| | - Guozhen Yang
- Department of Chemical and Biomolecular Engineering
- University of Houston
- Houston
- USA
| | - Megan L. Robertson
- Department of Chemical and Biomolecular Engineering
- University of Houston
- Houston
- USA
- Department of Chemistry
| |
Collapse
|
26
|
Milosevic M, Stojanovic D, Simic V, Milicevic B, Radisavljevic A, Uskokovic P, Kojic M. A Computational Model for Drug Release from PLGA Implant. MATERIALS (BASEL, SWITZERLAND) 2018; 11:E2416. [PMID: 30501079 PMCID: PMC6316994 DOI: 10.3390/ma11122416] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Revised: 11/18/2018] [Accepted: 11/20/2018] [Indexed: 11/23/2022]
Abstract
Due to the relative ease of producing nanofibers with a core⁻shell structure, emulsion electrospinning has been investigated intensively in making nanofibrous drug delivery systems for controlled and sustained release. Predictions of drug release rates from the poly (d,l-lactic-co-glycolic acid) (PLGA) produced via emulsion electrospinning can be a very difficult task due to the complexity of the system. A computational finite element methodology was used to calculate the diffusion mass transport of Rhodamine B (fluorescent drug model). Degradation effects and hydrophobicity (partitioning phenomenon) at the fiber/surrounding interface were included in the models. The results are validated by experiments where electrospun PLGA nanofiber mats with different contents were used. A new approach to three-dimensional (3D) modeling of nanofibers is presented in this work. The authors have introduced two original models for diffusive drug release from nanofibers to the 3D surrounding medium discretized by continuum 3D finite elements: (1) A model with simple radial one-dimensional (1D) finite elements, and (2) a model consisting of composite smeared finite elements (CSFEs). Numerical solutions, compared to experiments, demonstrate that both computational models provide accurate predictions of the diffusion process and can therefore serve as efficient tools for describing transport inside a polymer fiber network and drug release to the surrounding porous medium.
Collapse
Affiliation(s)
- Miljan Milosevic
- Bioengineering Research and Development Center BioIRC Kragujevac, Prvoslava Stojanovica 6, 34000 Kragujevac, Serbia.
- Belgrade Metropolitan University, Tadeuša Košćuška 63, 11000 Belgrade, Serbia.
| | - Dusica Stojanovic
- Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, 11000 Belgrade, Serbia.
| | - Vladimir Simic
- Bioengineering Research and Development Center BioIRC Kragujevac, Prvoslava Stojanovica 6, 34000 Kragujevac, Serbia.
| | - Bogdan Milicevic
- Bioengineering Research and Development Center BioIRC Kragujevac, Prvoslava Stojanovica 6, 34000 Kragujevac, Serbia.
| | - Andjela Radisavljevic
- Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, 11000 Belgrade, Serbia.
| | - Petar Uskokovic
- Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, 11000 Belgrade, Serbia.
| | - Milos Kojic
- Bioengineering Research and Development Center BioIRC Kragujevac, Prvoslava Stojanovica 6, 34000 Kragujevac, Serbia.
- Houston Methodist Research Institute, The Department of Nanomedicine, 6670 Bertner Ave., R7 117, Houston, TX 77030, USA.
- Serbian Academy of Sciences and Arts, Knez Mihailova 35, 11000 Belgrade, Serbia.
| |
Collapse
|
27
|
Chakravarty K, Dalal DC. A Nonlinear Mathematical Model of Drug Delivery from Polymeric Matrix. Bull Math Biol 2018; 81:105-130. [PMID: 30298197 DOI: 10.1007/s11538-018-0519-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Accepted: 09/28/2018] [Indexed: 12/30/2022]
Abstract
The objective of the present study is to mathematically model the integrated kinetics of drug release in a polymeric matrix and its ensuing drug transport to the encompassing biological tissue. The model embodies drug diffusion, dissolution, solubilization, polymer degradation and dissociation/recrystallization phenomena in the polymeric matrix accompanied by diffusion, advection, reaction, internalization and specific/nonspecific binding in the biological tissue. The model is formulated through a system of nonlinear partial differential equations which are solved numerically in association with pertinent set of initial, interface and boundary conditions using suitable finite difference scheme. After spatial discretization, the system of nonlinear partial differential equations is reduced to a system of nonlinear ordinary differential equations which is subsequently solved by the fourth-order Runge-Kutta method. The model simulations deal with the comparison between a drug delivery from a biodegradable polymeric matrix and that from a biodurable polymeric matrix. Furthermore, simulated results are compared with corresponding existing experimental data to manifest the efficaciousness of the advocated model. A quantitative analysis is performed through numerical computation relied on model parameter values. The numerical results obtained reveal an estimate of the effects of biodegradable and biodurable polymeric matrices on drug release rates. Furthermore, through graphical representations, the sensitized impact of the model parameters on the drug kinetics is illustrated so as to assess the model parameters of significance.
Collapse
Affiliation(s)
- Koyel Chakravarty
- Department of Mathematics, Indian Institute of Technology Guwahati, Guwahati, 781039, India.
| | - D C Dalal
- Department of Mathematics, Indian Institute of Technology Guwahati, Guwahati, 781039, India
| |
Collapse
|
28
|
The effect of plaque eccentricity on blood hemodynamics and drug release in a stented artery. Med Eng Phys 2018; 60:47-60. [DOI: 10.1016/j.medengphy.2018.07.014] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2017] [Revised: 07/20/2018] [Accepted: 07/24/2018] [Indexed: 11/17/2022]
|
29
|
Biswaro LS, Garcia MP, da Silva JR, Neira Fuentes LF, Vera A, Escobar P, Azevedo RB. Itraconazole encapsulated PLGA-nanoparticles covered with mannose as potential candidates against leishmaniasis. J Biomed Mater Res B Appl Biomater 2018; 107:680-687. [PMID: 30091522 DOI: 10.1002/jbm.b.34161] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Revised: 03/21/2018] [Accepted: 04/29/2018] [Indexed: 11/06/2022]
Abstract
Leishmaniasis is a neglected disease threatening over 350 million people. Antimonials are first-line drugs due to resistance and side effects there is a demand for alternative chemotherapy. Itraconazole (ITZ) is an antimycotic. It was encapsulated into poly(lactic-co-glycolic acid) (PLGA) nanoparticles (NPs) and covered with mannose. The NPs were 250 nm and -1.1 mV ± 0.7. PLGA-ITZ-mannose NPs presented a toxicity of 20.7% for J774 cells, and no toxicity for THP 1. The J774 cells were infected with three Leishmania promastigotes strains and treated with ITZ loaded PLGA NPs with/without mannose. The parasite percentage of L.(V.) panamensis intracellular amastigotes significantly (p < 0.01) decreased from 34.4% to 13.7% and 5.7% for PLGA-ITZ-mannose NPs and PLGA-ITZ NPs, respectively. For L.(L.) infantum there was a reduction (p < 0.001) from 18.1% to 4.8% and 8.3% for PLGA-ITZ-mannose NPs and PLGA-ITZ NPs, respectively. Further with L.(L.) braziliensis amastigotes there was a significant reduction (p < 0.001) from 54.9% to 28% and 21.1% for PLGA-ITZ-mannose NPs and PLGA-ITZ NPs, respectively. Adding mannose increased the efficacy PLGA-ITZ NPs against L.(L.) infantum, while it had no effect against L(V.) panamensis and L.(L.) braziliensis amastigotes. We recommend further investigation of PLGA-ITZ-mannose NPs in animal models to evaluate their potential. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 00B: 000-000, 2018. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 680-687, 2019.
Collapse
Affiliation(s)
- Lubhandwa Sebastian Biswaro
- Departamento de Genética e Morfologia, Instituto de Ciências Biológicas, Universidade de Brasilia, Brasilia, DF, Brazil
| | - Mônica Pereira Garcia
- Departamento de Genética e Morfologia, Instituto de Ciências Biológicas, Universidade de Brasilia, Brasilia, DF, Brazil
| | - Jaqueline Rodrigues da Silva
- Departamento de Genética e Morfologia, Instituto de Ciências Biológicas, Universidade de Brasilia, Brasilia, DF, Brazil
| | - Laura Fernanda Neira Fuentes
- Centro de Investigación de Enfermedades Tropicales (CINTROP), Facultad de Salud, Escuela de Medicina, Departamento de Ciencias Básicas, Universidad Industrial de Santander, Bucaramanga, Colombia
| | - Angelica Vera
- Centro de Investigación de Enfermedades Tropicales (CINTROP), Facultad de Salud, Escuela de Medicina, Departamento de Ciencias Básicas, Universidad Industrial de Santander, Bucaramanga, Colombia
| | - Patricia Escobar
- Centro de Investigación de Enfermedades Tropicales (CINTROP), Facultad de Salud, Escuela de Medicina, Departamento de Ciencias Básicas, Universidad Industrial de Santander, Bucaramanga, Colombia
| | - Ricardo Bentes Azevedo
- Departamento de Genética e Morfologia, Instituto de Ciências Biológicas, Universidade de Brasilia, Brasilia, DF, Brazil
| |
Collapse
|
30
|
Kharel S, Gautam A, Dickescheid A, Loo SCJ. Hollow Microparticles as a Superior Delivery System over Solid Microparticles for the Encapsulation of Peptides. Pharm Res 2018; 35:185. [PMID: 30073514 DOI: 10.1007/s11095-018-2461-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Accepted: 07/15/2018] [Indexed: 12/27/2022]
|
31
|
Chang JK, Chang HP, Guo Q, Koo J, Wu CI, Rogers JA. Biodegradable Electronic Systems in 3D, Heterogeneously Integrated Formats. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2018; 30:1704955. [PMID: 29349821 DOI: 10.1002/adma.201704955] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Revised: 11/30/2017] [Indexed: 06/07/2023]
Abstract
Biodegradable electronic systems represent an emerging class of technology with unique application possibilities, from temporary biomedical implants to "green" consumer gadgets. This paper introduces materials and processing methods for 3D, heterogeneously integrated devices of this type, with various functional examples in sophisticated forms of silicon-based electronics. Specifically, techniques for performing multilayer assembly by transfer printing and for fabricating layer-to-layer vias and interconnects by lithographic procedures serve as routes to biodegradable, 3D integrated circuits composed of functional building blocks formed using specialized approaches or sourced from commercial semiconductor foundries. Demonstration examples range from logic gates and analog circuits that undergo functional transformation by transience to systems that integrate multilayer resistive sensors for in situ, continuous electrical monitoring of the processes of transience. The results significantly expand the scope of engineering options for biodegradable electronics and other types of transient microsystem technologies.
Collapse
Affiliation(s)
- Jan-Kai Chang
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL, 60208, USA
| | - Hui-Ping Chang
- Institute of Photonics and Optoelectronics, National Taiwan University, Taipei, 10617, Taiwan
- Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Qinglei Guo
- Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
- Department of Materials Science, Fudan University, Shanghai, 200433, P. R. China
| | - Jahyun Koo
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL, 60208, USA
| | - Chih-I Wu
- Institute of Photonics and Optoelectronics, National Taiwan University, Taipei, 10617, Taiwan
| | - John A Rogers
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL, 60208, USA
- Department of Materials Science and Engineering, Department of Biomedical Engineering, Department of Neurological Surgery, Department of Chemistry, Department of Mechanical Engineering, Department of Electrical Engineering, and Department of Computer Science, Simpson Querrey Institute, Feinberg Medical School, Northwestern University, Evanston, IL, 60208, USA
| |
Collapse
|
32
|
Chakravarty K, Dalal DC. An analytical study of drug release kinetics from a degradable polymeric matrix. INT J BIOMATH 2018. [DOI: 10.1142/s1793524518500110] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
In modern days, biodegradable polymeric matrix used as the kingpin of local drug delivery system is in the center of attention. This work is concentrated on the formulation of mathematical model elucidating degradation of drug-loaded polymeric matrix followed by drug release to the adjacent biological tissues. Polymeric degradation is penciled with mass conservation equations. Drug release phenomenon is modeled by considering solubilization dynamics of drug particles, diffusion of the solubilized drug through polymeric matrix along with reversible dissociation/recrystallization process. In the tissue phase, reversible dissociation/association along with internalization processes of drug are taken into account. For this, a two-phase spatio-temporal model is postulated, which has ensued to a system of partial differential equations. They are solved analytically with appropriate choice of initial, interface and boundary conditions. In order to reflect the potency of the advocated model, the simulated results are analogized with corresponding experimental data and found laudable agreement so as to validate the applicability of the model considered. This model seems to foster the delicacy of the mantle enacted by important drug kinetic parameters such as diffusion coefficients, mass transfer coefficients, particle binding and internalization parameters, which is illustrated through local sensitivity analysis.
Collapse
Affiliation(s)
- Koyel Chakravarty
- Department of Mathematics, Indian Institute of Technology Guwahati, Guwahati 781039, India
| | - D. C. Dalal
- Department of Mathematics, Indian Institute of Technology Guwahati, Guwahati 781039, India
| |
Collapse
|
33
|
Duo X, Li Q, Wang J, Lv J, Hao X, Feng Y, Ren X, Shi C, Zhang W. Core/Shell Gene Carriers with Different Lengths of PLGA Chains to Transfect Endothelial Cells. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2017; 33:13315-13325. [PMID: 29100464 DOI: 10.1021/acs.langmuir.7b02934] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
In order to improve the transfection efficiency and reduce the cytotoxicity of gene carriers, many strategies have been used to develop novel gene carriers. In this study, five complex micelles (MSP(2 k), MSP(4 k), MSP(6 k), MSP(8 k), and MSP(10 k)) were prepared from methoxy-poly(ethylene glycol)-b-poly(d,l-lactide-co-glycolide) (mPEG-b-PLGA) and sorbitol-poly(d,l-lactide-co-glycolide)-graft-PEI (sorbitol-PLGA-g-PEI, where the designed molecular weights of PLGA chains were 2 kDa, 4 kDa, 6 kDa, 8 kDa, and 10 kDa, respectively) copolymers by a self-assembly method, and the mass ratio of mPEG-b-PLGA to sorbitol-PLGA-g-PEI was 1/3. These complex micelles and their gene complexes had appropriate sizes and zeta potentials, and pEGFP-ZNF580 (pDNA) could be efficiently internalized into EA.hy926 cells by their gene complexes (MSP(2 k)/pDNA, MSP(4 k)/pDNA, MSP(6 k)/pDNA, MSP(8 k)/pDNA, and MSP(10 k)/pDNA). The MTT assay results demonstrated that the gene complexes had low cytotoxicity in vitro. When the hydrophobic PLGA chain increased above 6 kDa, the gene complexes showed higher performance than that prepared from short hydrophobic chains. Moreover, the relative ZNF580 protein expression levels in MSP(6 k)/pDNA, MSP(8 k)/pDNA, and MSP(10 k)/pDNA) groups were 79.6%, 71.2%, and 73%, respectively. These gene complexes could promote the transfection of endothelial cells, while providing important information and insight for the design of new and effective gene carriers to promote the proliferation and migration of endothelial cells.
Collapse
Affiliation(s)
- Xinghong Duo
- School of Chemical Engineering and Technology, Tianjin University , Yaguan Road 135, Tianjin 300350, China
- School of Chemistry and Chemical Engineering, Qinghai University for Nationalities , Bayi middle Road 3, Xining, Qinghai 810007, China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin) , Weijin Road 92, Tianjin 300072, China
| | - Qian Li
- School of Chemical Engineering and Technology, Tianjin University , Yaguan Road 135, Tianjin 300350, China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin) , Weijin Road 92, Tianjin 300072, China
| | - Jun Wang
- School of Chemical Engineering and Technology, Tianjin University , Yaguan Road 135, Tianjin 300350, China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin) , Weijin Road 92, Tianjin 300072, China
| | - Juan Lv
- School of Chemical Engineering and Technology, Tianjin University , Yaguan Road 135, Tianjin 300350, China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin) , Weijin Road 92, Tianjin 300072, China
| | - Xuefang Hao
- School of Chemical Engineering and Technology, Tianjin University , Yaguan Road 135, Tianjin 300350, China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin) , Weijin Road 92, Tianjin 300072, China
| | - Yakai Feng
- School of Chemical Engineering and Technology, Tianjin University , Yaguan Road 135, Tianjin 300350, China
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin) , Weijin Road 92, Tianjin 300072, China
- Joint Laboratory for Biomaterials and Regenerative Medicine, Tianjin University-Helmholtz-Zentrum Geesthacht , Yaguan Road 135, Tianjin 300350, China
- Key Laboratory of Systems Bioengineering of Ministry of Education, Tianjin University , Yaguan Road 135, Tianjin 300350, China
| | - Xiangkui Ren
- School of Chemical Engineering and Technology, Tianjin University , Yaguan Road 135, Tianjin 300350, China
| | - Changcan Shi
- Wenzhou Institute of Biomaterials and Engineering, CNITECH, CAS , Wenzhou, Zhejiang 325011, China
- Institute of Biomaterials and Engineering, Wenzhou Medical University , Wenzhou, Zhejiang 325011, China
| | - Wencheng Zhang
- Department of Physiology and Pathophysiology, Logistics University of Chinese People's Armed Police Force , Tianjin 300162, China
| |
Collapse
|
34
|
Naghipoor J, Rabczuk T. A mechanistic model for drug release from PLGA-based drug eluting stent: A computational study. Comput Biol Med 2017; 90:15-22. [DOI: 10.1016/j.compbiomed.2017.09.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Revised: 09/01/2017] [Accepted: 09/01/2017] [Indexed: 11/15/2022]
|
35
|
Ultrasound-triggered PLGA microparticle destruction and degradation for controlled delivery of local cytotoxicity and drug release. Int J Biol Macromol 2017; 106:1211-1217. [PMID: 28851638 DOI: 10.1016/j.ijbiomac.2017.08.125] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2017] [Revised: 08/15/2017] [Accepted: 08/22/2017] [Indexed: 11/21/2022]
Abstract
In this study, we investigated the low intensity ultrasound (US)-controlled delivery of local cytotoxicity and drug release via induced destruction and degradation of microparticles (MPs) made of poly(lactic-co-glycolic acid) (PLGA). This study was conducted in vitro with potential application towards tumor treatment in conjunction with direct injection. MPs, either loaded with or without doxorubicin (DOX), were prepared using a double-emulsion solvent-evaporation technique. First, the MPs were exposed to US with duty cycle (DC)-modulation. The destruction and degradation of MPs were evaluated using light and scanning electron microscopy. Second, the effects of US-mediated destruction/degradation of MPs on the local cytotoxicity as well as DOX release were evaluated. US-triggered MP destruction/degradation significantly enhanced nearby cell death and DOX release. These affects occurred in proportion to the DC. Our findings indicate that controlled cytotoxicity and DOX release by US could be useful in developing the minimally invasive therapeutic applications for tumor treatment.
Collapse
|
36
|
Nabzdyk CS, Pradhan-Nabzdyk L, LoGerfo FW. RNAi therapy to the wall of arteries and veins: anatomical, physiologic, and pharmacological considerations. J Transl Med 2017; 15:164. [PMID: 28754174 PMCID: PMC5534068 DOI: 10.1186/s12967-017-1270-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Accepted: 07/20/2017] [Indexed: 12/02/2022] Open
Abstract
Background Cardiovascular disease remains a major health care challenge. The knowledge about the underlying mechanisms of the respective vascular disease etiologies has greatly expanded over the last decades. This includes the contribution of microRNAs, endogenous non-coding RNA molecules, known to vastly influence gene expression. In addition, short interference RNA has been established as a mechanism to temporarily affect gene expression. This review discusses challenges relating to the design of a RNA interference therapy strategy for the modulation of vascular disease. Despite advances in medical and surgical therapies, atherosclerosis (ATH), aortic aneurysms (AA) are still associated with high morbidity and mortality. In addition, intimal hyperplasia (IH) remains a leading cause of late vein and prosthetic bypass graft failure. Pathomechanisms of all three entities include activation of endothelial cells (EC) and dedifferentiation of vascular smooth muscle cells (VSMC). RNA interference represents a promising technology that may be utilized to silence genes contributing to ATH, AA or IH. Successful RNAi delivery to the vessel wall faces multiple obstacles. These include the challenge of cell specific, targeted delivery of RNAi, anatomical barriers such as basal membrane, elastic laminae in arterial walls, multiple layers of VSMC, as well as adventitial tissues. Another major decision point is the route of delivery and potential methods of transfection. A plethora of transfection reagents and adjuncts have been described with varying efficacies and side effects. Timing and duration of RNAi therapy as well as target gene choice are further relevant aspects that need to be addressed in a temporo-spatial fashion. Conclusions While multiple preclinical studies reported encouraging results of RNAi delivery to the vascular wall, it remains to be seen if a single target can be sufficient to the achieve clinically desirable changes in the injured vascular wall in humans. It might be necessary to achieve simultaneous and/or sequential silencing of multiple, synergistically acting target genes. Some advances in cell specific RNAi delivery have been made, but a reliable vascular cell specific transfection strategy is still missing. Also, off-target effects of RNAi and unwanted effects of transfection agents on gene expression are challenges to be addressed. Close collaborative efforts between clinicians, geneticists, biologists, and chemical and medical engineers will be needed to provide tailored therapeutics for the various types of vascular diseases.
Collapse
Affiliation(s)
- Christoph S Nabzdyk
- Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.,Frank W. LoGerfo Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis Street, Boston, MA, 02215, USA
| | - Leena Pradhan-Nabzdyk
- Frank W. LoGerfo Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis Street, Boston, MA, 02215, USA.
| | - Frank W LoGerfo
- Frank W. LoGerfo Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis Street, Boston, MA, 02215, USA
| |
Collapse
|
37
|
Li Y, Chu Z, Li X, Ding X, Guo M, Zhao H, Yao J, Wang L, Cai Q, Fan Y. The effect of mechanical loads on the degradation of aliphatic biodegradable polyesters. Regen Biomater 2017; 4:179-190. [PMID: 28596915 PMCID: PMC5458542 DOI: 10.1093/rb/rbx009] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Revised: 03/01/2017] [Accepted: 03/06/2017] [Indexed: 12/11/2022] Open
Abstract
Aliphatic biodegradable polyesters have been the most widely used synthetic polymers for developing biodegradable devices as alternatives for the currently used permanent medical devices. The performances during biodegradation process play crucial roles for final realization of their functions. Because physiological and biochemical environment in vivo significantly affects biodegradation process, large numbers of studies on effects of mechanical loads on the degradation of aliphatic biodegradable polyesters have been launched during last decades. In this review article, we discussed the mechanism of biodegradation and several different mechanical loads that have been reported to affect the biodegradation process. Other physiological and biochemical factors related to mechanical loads were also discussed. The mechanical load could change the conformational strain energy and morphology to weaken the stability of the polymer. Besides, the load and pattern could accelerate the loss of intrinsic mechanical properties of polymers. This indicated that investigations into effects of mechanical loads on the degradation should be indispensable. More combination condition of mechanical loads and multiple factors should be considered in order to keep the degradation rate controllable and evaluate the degradation process in vivo accurately. Only then can the degradable devise achieve the desired effects and further expand the special applications of aliphatic biodegradable polyesters.
Collapse
Affiliation(s)
- Ying Li
- School of Biological Science and Medical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beihang University, Beijing 100191, People's Republic of China
| | - Zhaowei Chu
- School of Biological Science and Medical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beihang University, Beijing 100191, People's Republic of China
| | - Xiaoming Li
- School of Biological Science and Medical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beihang University, Beijing 100191, People's Republic of China
| | - Xili Ding
- School of Biological Science and Medical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beihang University, Beijing 100191, People's Republic of China
| | - Meng Guo
- School of Biological Science and Medical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beihang University, Beijing 100191, People's Republic of China
| | - Haoran Zhao
- Department of Biomedical Engineer, University of Cincinnati, Cincinnati, OH 45221, USA
| | - Jie Yao
- School of Biological Science and Medical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beihang University, Beijing 100191, People's Republic of China
| | - Lizhen Wang
- School of Biological Science and Medical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beihang University, Beijing 100191, People's Republic of China
| | - Qiang Cai
- Key Laboratory of Advanced Materials of Ministry of Education of China, Tsinghua University, Beijing 100084, People's Republic of China
| | - Yubo Fan
- School of Biological Science and Medical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beihang University, Beijing 100191, People's Republic of China.,National Research Center for Rehabilitation Technical Aids, Beijing 100176, People's Republic of China
| |
Collapse
|
38
|
Enayati M, Mobedi H, Hojjati-Emami S, Mirzadeh H, Jafari-Nodoushan M. In situ
forming PLGA implant for 90 days controlled release of leuprolide acetate for treatment of prostate cancer. POLYM ADVAN TECHNOL 2017. [DOI: 10.1002/pat.3991] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Affiliation(s)
- Marjan Enayati
- Department of Biomedical Research; Medical University of Vienna; Vienna Austria
- Department of Biomedical Engineering; Tehran Polytechnique University; 424, Hafez Ave., 15875-4413 Tehran Iran
| | - Hamid Mobedi
- Novel Drug Delivery Systems Department; Iran Polymer and Petrochemical Institute; P.O. Box 14965-115 Tehran Iran
| | - Shahriar Hojjati-Emami
- Department of Biomedical Engineering; Tehran Polytechnique University; 424, Hafez Ave., 15875-4413 Tehran Iran
| | - Hamid Mirzadeh
- Department of Biomedical Engineering; Tehran Polytechnique University; 424, Hafez Ave., 15875-4413 Tehran Iran
| | - Milad Jafari-Nodoushan
- Novel Drug Delivery Systems Department; Iran Polymer and Petrochemical Institute; P.O. Box 14965-115 Tehran Iran
| |
Collapse
|
39
|
Koenig O, Zengerle D, Perle N, Hossfeld S, Neumann B, Behring A, Avci-Adali M, Walker T, Schlensak C, Wendel HP, Nolte A. RNA-Eluting Surfaces for the Modulation of Gene Expression as A Novel Stent Concept. Pharmaceuticals (Basel) 2017; 10:ph10010023. [PMID: 28208634 PMCID: PMC5374427 DOI: 10.3390/ph10010023] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Accepted: 02/06/2017] [Indexed: 02/06/2023] Open
Abstract
Presently, a new era of drug-eluting stents is continuing to improve late adverse effects such as thrombosis after coronary stent implantation in atherosclerotic vessels. The application of gene expression–modulating stents releasing specific small interfering RNAs (siRNAs) or messenger RNAs (mRNAs) to the vascular wall might have the potential to improve the regeneration of the vessel wall and to inhibit adverse effects as a new promising therapeutic strategy. Different poly (lactic-co-glycolic acid) (PLGA) resomers for their ability as an siRNA delivery carrier against intercellular adhesion molecule (ICAM)-1 with a depot effect were tested. Biodegradability, hemocompatibility, and high cell viability were found in all PLGAs. We generated PLGA coatings with incorporated siRNA that were able to transfect EA.hy926 and human vascular endothelial cells. Transfected EA.hy926 showed significant siICAM-1 knockdown. Furthermore, co-transfection of siRNA and enhanced green fluorescent protein (eGFP) mRNA led to the expression of eGFP as well as to the siRNA transfection. Using our PLGA and siRNA multilayers, we reached high transfection efficiencies in EA.hy926 cells until day six and long-lasting transfection until day 20. Our results indicate that siRNA and mRNA nanoparticles incorporated in PLGA films have the potential for the modulation of gene expression after stent implantation to achieve accelerated regeneration of endothelial cells and to reduce the risk of restenosis.
Collapse
Affiliation(s)
- Olivia Koenig
- Department of Thoracic, Cardiac, and Vascular Surgery, University of Tuebingen, Calwerstraße 7/1, 72076 Tuebingen, Germany.
| | - Diane Zengerle
- Department of Thoracic, Cardiac, and Vascular Surgery, University of Tuebingen, Calwerstraße 7/1, 72076 Tuebingen, Germany.
| | - Nadja Perle
- Department of Thoracic, Cardiac, and Vascular Surgery, University of Tuebingen, Calwerstraße 7/1, 72076 Tuebingen, Germany.
| | - Susanne Hossfeld
- Department of Thoracic, Cardiac, and Vascular Surgery, University of Tuebingen, Calwerstraße 7/1, 72076 Tuebingen, Germany.
| | - Bernd Neumann
- Department of Thoracic, Cardiac, and Vascular Surgery, University of Tuebingen, Calwerstraße 7/1, 72076 Tuebingen, Germany.
| | - Andreas Behring
- Department of Thoracic, Cardiac, and Vascular Surgery, University of Tuebingen, Calwerstraße 7/1, 72076 Tuebingen, Germany.
| | - Meltem Avci-Adali
- Department of Thoracic, Cardiac, and Vascular Surgery, University of Tuebingen, Calwerstraße 7/1, 72076 Tuebingen, Germany.
| | - Tobias Walker
- Department of Thoracic, Cardiac, and Vascular Surgery, University of Tuebingen, Calwerstraße 7/1, 72076 Tuebingen, Germany.
| | - Christian Schlensak
- Department of Thoracic, Cardiac, and Vascular Surgery, University of Tuebingen, Calwerstraße 7/1, 72076 Tuebingen, Germany.
| | - Hans Peter Wendel
- Department of Thoracic, Cardiac, and Vascular Surgery, University of Tuebingen, Calwerstraße 7/1, 72076 Tuebingen, Germany.
| | - Andrea Nolte
- Department of Thoracic, Cardiac, and Vascular Surgery, University of Tuebingen, Calwerstraße 7/1, 72076 Tuebingen, Germany.
| |
Collapse
|
40
|
Ferreira JA, Gonçalves L, Naghipoor J, de Oliveira P, Rabczuk T. The influence of atherosclerotic plaques on the pharmacokinetics of a drug eluted from bioabsorbable stents. Math Biosci 2017; 283:71-83. [DOI: 10.1016/j.mbs.2016.11.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 09/03/2016] [Accepted: 11/05/2016] [Indexed: 11/28/2022]
|
41
|
Zhang Z, Wang X, Zhu R, Wang Y, Li B, Ma Y, Yin Y. Synthesis and characterization of serial random and block-copolymers based on lactide and glycolide. POLYMER SCIENCE SERIES B 2016. [DOI: 10.1134/s1560090416060191] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
42
|
Chu Z, Li X, Li Y, Zheng Q, Feng C, Guo M, Ding X, Feng W, Gao Y, Yao J, Chen X, Wang L, Fan Y. Effects of different fluid shear stress patterns on the in vitro degradation of poly(lactide-co-glycolide) acid membranes. J Biomed Mater Res A 2016; 105:23-30. [PMID: 27507409 DOI: 10.1002/jbm.a.35860] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2016] [Revised: 07/26/2016] [Accepted: 08/05/2016] [Indexed: 01/30/2023]
Abstract
The applications of poly (lactide-co-glycolide) acid (PLGA) for coating or fabricating polymeric biodegradable stents (BDSs) have drawn more attention. The fluid shear stress has been proved to affect the in vitro degradation process of PLGA membranes. During the maintenance, BDSs could be suffered different patterns of fluid shear stress, but the effect of these different patterns on the whole degradation process is unclear. In this study, in vitro degradation of PLGA membranes was examined with steady, sinusoid, and squarewave fluid shear stress patterns in 150 mL deionized water at 37°C for 20 days, emphasizing on the changes in the viscosity of the degradation solution, mechanical, and morphological properties of the samples. The unsteady fluid shear stress with the same average magnitude as the steady one accelerate the in vitro degradation process of PLGA membranes in terms of maximum fluid shear stress and "window" of effectiveness. Maximum fluid shear stress accelerates the in vitro degradation of molecular fragments that diffused out in the solution while the "window" of effectiveness affects too in the early stage. Besides, maximum fluid shear stress and "window" of effectiveness accelerates the in vitro loss of tensile modulus and ultimate strength of the PLGA membranes while the maximum fluid shear stress plays the leading role in the decrease of tensile modulus at the early degradation stage. This study could help advance the degradation design of PLGA membranes under different fluid shear stress patterns for biomedical applications like stents and drug release systems. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 23-30, 2017.
Collapse
Affiliation(s)
- Zhaowei Chu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beijing, China.,Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Xiaoming Li
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beijing, China.,Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Ying Li
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beijing, China.,Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Quan Zheng
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beijing, China.,Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Chenglong Feng
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beijing, China.,Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Meng Guo
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beijing, China.,Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Xili Ding
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beijing, China.,Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Wentao Feng
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beijing, China.,Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yuanming Gao
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beijing, China.,Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Jie Yao
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beijing, China.,Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Xiaofang Chen
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beijing, China.,Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Lizhen Wang
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beijing, China.,Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yubo Fan
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Beijing, China.,Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.,National Research Center for Rehabilitation Technical Aids, Beijing, China
| |
Collapse
|
43
|
Chu Z, Zheng Q, Guo M, Yao J, Xu P, Feng W, Hou Y, Zhou G, Wang L, Li X, Fan Y. The effect of fluid shear stress on thein vitrodegradation of poly(lactide-co-glycolide) acid membranes. J Biomed Mater Res A 2016; 104:2315-24. [DOI: 10.1002/jbm.a.35766] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Revised: 04/25/2016] [Accepted: 04/26/2016] [Indexed: 12/25/2022]
Affiliation(s)
- Zhaowei Chu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering; Beihang University; Beijing People's Republic of China
| | - Quan Zheng
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering; Beihang University; Beijing People's Republic of China
| | - Meng Guo
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering; Beihang University; Beijing People's Republic of China
| | - Jie Yao
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering; Beihang University; Beijing People's Republic of China
| | - Peng Xu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering; Beihang University; Beijing People's Republic of China
| | - Wentao Feng
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering; Beihang University; Beijing People's Republic of China
| | - Yongzhao Hou
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering; Beihang University; Beijing People's Republic of China
| | - Gang Zhou
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering; Beihang University; Beijing People's Republic of China
| | - Lizhen Wang
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering; Beihang University; Beijing People's Republic of China
| | - Xiaoming Li
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering; Beihang University; Beijing People's Republic of China
| | - Yubo Fan
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, International Research Center for Implantable and Interventional Medical Devices, Key Laboratory for Optimal Design and Evaluation Technology of Implantable & Interventional Medical Devices, School of Biological Science and Medical Engineering; Beihang University; Beijing People's Republic of China
- National Research Center for Rehabilitation Technical Aids; Beijing People's Republic of China
| |
Collapse
|
44
|
Xu Y, Kim CS, Saylor DM, Koo D. Polymer degradation and drug delivery in PLGA-based drug-polymer applications: A review of experiments and theories. J Biomed Mater Res B Appl Biomater 2016; 105:1692-1716. [PMID: 27098357 DOI: 10.1002/jbm.b.33648] [Citation(s) in RCA: 223] [Impact Index Per Article: 27.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Revised: 01/25/2016] [Accepted: 02/12/2016] [Indexed: 01/03/2023]
Abstract
Poly (lactic-co-glycolic acid) (PLGA) copolymers have been broadly used in controlled drug release applications. Because these polymers are biodegradable, they provide an attractive option for drug delivery vehicles. There are a variety of material, processing, and physiological factors that impact the degradation rates of PLGA polymers and concurrent drug release kinetics. This work is intended to provide a comprehensive and collective review of the physicochemical and physiological factors that dictate the degradation behavior of PLGA polymers and drug release from contemporary PLGA-based drug-polymer products. In conjunction with the existing experimental results, analytical and numerical theories developed to predict drug release from PLGA-based polymers are summarized and correlated with the experimental observations. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1692-1716, 2017.
Collapse
Affiliation(s)
- Yihan Xu
- Materials Science and Engineering Department, University of Wisconsin-Milwaukee, Milwaukee, Wisconsin, 53211
| | - Chang-Soo Kim
- Materials Science and Engineering Department, University of Wisconsin-Milwaukee, Milwaukee, Wisconsin, 53211
| | - David M Saylor
- Division of Biology, Chemistry, and Materials Science, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, 20993
| | - Donghun Koo
- Materials Science R&D, MilliporeSigma, Milwaukee, Wisconsin, 53209
| |
Collapse
|
45
|
Synthesis, Properties, and In Vitro Hydrolytic Degradation of Poly(d,l-lactide-co-glycolide-co-ε-caprolactone). INT J POLYM SCI 2016. [DOI: 10.1155/2016/8082014] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Random copolymers of poly(d,l-lactide-co-glycolide-co-ε-caprolactone) (PLGC) were synthesized by the ring-opening polymerization of d,l-lactide (DLLA), glycolide (GA), andε-caprolactone (CL). The effects of CL on the copolymers were evaluated to prepare suitable copolymers with controlled properties. Our results showed that the CL content significantly influenced the thermal and mechanical properties of the copolymers and that the CL content in compositions could be altered to control properties of random copolymers. The in vitro hydrolytic degradation of the resulting implants showed that the degradation rate of PLGC was lower than that of PLGA, which could markedly reduce acidic degradation products. Finally, we demonstrated that higher CL contents in compositions slowed degradation rates.
Collapse
|
46
|
Controlling drug delivery from coronary stents: are we aiming for the right targets? Ther Deliv 2015; 6:705-20. [PMID: 26149786 DOI: 10.4155/tde.15.25] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
In this review article, the currently employed or explored delivery concepts for local intravascular drug delivery with drug-eluting stents (DES) are discussed with a special emphasis on clinical evidence regarding the desired release profiles. Traditional concepts to control drug release from DES include diffusion through polymers, polymer degradation and erosion as well as dissolution of particulate drug. Published clinical studies do not always reveal fine mechanistic details. The long duration of release favored for DES and the short duration of release favored for drug-eluting balloons require further investigation in experimental studies and clinical trials.
Collapse
|
47
|
Zhu X, Braatz RD. Modeling and analysis of drug-eluting stents with biodegradable PLGA coating: consequences on intravascular drug delivery. J Biomech Eng 2015; 136:1894901. [PMID: 25084767 DOI: 10.1115/1.4028135] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2014] [Indexed: 11/08/2022]
Abstract
Increasing interests have been raised toward the potential applications of biodegradable poly(lactic-co-glycolic acid) (PLGA) coatings for drug-eluting stents in order to improve the drug delivery and reduce adverse outcomes in stented arteries in patients. This article presents a mathematical model to describe the integrated processes of drug release in a stent with PLGA coating and subsequent drug delivery, distribution, and drug pharmacokinetics in the arterial wall. The integrated model takes into account the PLGA degradation and erosion, anisotropic drug diffusion in the arterial wall, and reversible drug binding. The model simulations first compare the drug delivery from a biodegradable PLGA coating with that from a biodurable coating, including the drug release profiles in the coating, average arterial drug levels, and arterial drug distribution. Using the model for the PLGA stent coating, the simulations further investigate drug internalization, interstitial fluid flow in the arterial wall, and stent embedment for their impact on drug delivery. Simulation results show that these three factors, while imposing little change in the drug release profiles, can greatly change the average drug concentrations in the arterial wall. In particular, each of the factors leads to significant and yet distinguished alterations in the arterial drug distribution that can potentially influence the treatment outcomes. The detailed integrated model provides insights into the design and evaluation of biodegradable PLGA-coated drug-eluting stents for improved intravascular drug delivery.
Collapse
|