1
|
Badran G, Grare C, Masson JD, David MO, Achour D, Guidice JML, Garçon G, Crépeaux G. Difference in the cellular response following THP-1 derived phagocytic monocyte cells exposure to commercial aluminum-based adjuvants and aluminum-containing vaccines. J Trace Elem Med Biol 2024; 83:127394. [PMID: 38262194 DOI: 10.1016/j.jtemb.2024.127394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 01/12/2024] [Accepted: 01/12/2024] [Indexed: 01/25/2024]
Abstract
BACKGROUND Aluminum-based adjuvants (ABAs) enhance the immune response following vaccine injection. Their mechanisms of action are not fully understood, and their bio-persistency have been described associated with long-term adverse effects. METHODS We evaluated and compared the cellular effects of the two main ABAs and whole vaccines on ATP production, ROS generation and cytokines production (IL-6 and IL-10), using THP-1 cells. RESULTS ABAs altered the cell energy metabolism by increasing ROS production after 24 h and reducing ATP production after 48 h. In addition, both ABAs and whole vaccines induced different kinetics of IL-6 production, whereas only ABAs induced IL-10 secretion. CONCLUSION This study showed clearly, for a first time, a difference in cellular response to the ABAs and whole vaccines which should be taken into consideration in future studies focusing on the effect of ABA in vaccines. Future studies on ABAs should also pay attention to mitochondrial function alterations following exposure to ABA-containing vaccines.
Collapse
Affiliation(s)
- Ghidaa Badran
- Univ Paris Est Créteil, INSERM, IMRB, F-94010 Créteil, France.
| | - Céline Grare
- CHU Lille, Institut Pasteur de Lille, ULR 4483-IMPacts de l'Environnement Chimique sur la Santé (IMPECS), Univ. Lille, Lille, France
| | | | - Marie-Odile David
- Université Paris-Saclay, Inserm, Univ Evry, Structure-Activité des Biomolécules Normales et Pathologiques, U1204, 91025 Evry, France
| | - Djamal Achour
- CHU Lille, Institut Pasteur de Lille, ULR 4483-IMPacts de l'Environnement Chimique sur la Santé (IMPECS), Univ. Lille, Lille, France
| | - Jean-Marc Lo Guidice
- CHU Lille, Institut Pasteur de Lille, ULR 4483-IMPacts de l'Environnement Chimique sur la Santé (IMPECS), Univ. Lille, Lille, France
| | - Guillaume Garçon
- CHU Lille, Institut Pasteur de Lille, ULR 4483-IMPacts de l'Environnement Chimique sur la Santé (IMPECS), Univ. Lille, Lille, France
| | - Guillemette Crépeaux
- Univ Paris Est Créteil, INSERM, IMRB, F-94010 Créteil, France; Ecole Nationale Vétérinaire d'Alfort, IMRB, F-94700 Maisons-Alfort, France
| |
Collapse
|
2
|
Zhang Y, Liu X, Zhang X, Li L, Li Q, Geng H, Shi L, Wang B, Qiu Q, Yu T, Sang Y, Wang L, Liang J, Xu W. Association between serum heavy metal levels and diabetic retinopathy in NHANES 2011-2020. Sci Rep 2024; 14:1268. [PMID: 38218955 PMCID: PMC10787836 DOI: 10.1038/s41598-024-51749-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Accepted: 01/09/2024] [Indexed: 01/15/2024] Open
Abstract
The present study utilized the National Health and Nutrition Examination Survey (NHANES) database to examine the relationship between serum levels of heavy metals and Diabetic retinopathy (DR) in individuals aged over 30 years with type 2 diabetes mellitus (T2DM) in the United States. A cross-sectional analysis was conducted on 1583 individuals with T2DM from the NHANES 2011-2020, including 331 individuals in the DR group and 1252 individuals in the non-DR group. We collected data on serum levels of heavy metals, DR, and serum albumin for descriptive statistics, linear regression, and logistical regression analysis. After adjusting for age, gender, race and other factors, there was no statistically significant association between blood cadmium, selenium, mercury, or lead and DR. However, serum manganese (Mn) and DR had a significant negative association (β = - 0.2045, 95% CI = - 0.3484, - 0.0606). Serum albumin partially modulated the indirect influence of serum Mn on the incidence of DR, accounting for 12.80% of the association between serum Mn and DR. There was a negative association between serum Mn levels and the prevalence of DR in people with T2DM. Mn intake at least in this study has a little influence on the onset and development of DR.
Collapse
Affiliation(s)
- Yan Zhang
- The Xuzhou Clinical College of Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Xuekui Liu
- Department of Endocrinology, Xuzhou Central Hospital, Xuzhou Institute of Medical Sciences, Xuzhou Clinical School of Nanjing Medical University, Affiliated Hospital of Medical School of Southeast University, Xuzhou, Jiangsu, China
| | - Xia Zhang
- The Xuzhou Clinical College of Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Lin Li
- Bengbu Medical College, Bengbu, Anhui, China
| | - Qing Li
- The Xuzhou Clinical College of Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Houfa Geng
- Department of Endocrinology, Xuzhou Central Hospital, Xuzhou Institute of Medical Sciences, Xuzhou Clinical School of Nanjing Medical University, Affiliated Hospital of Medical School of Southeast University, Xuzhou, Jiangsu, China
| | - Li Shi
- Department of Endocrinology, Xuzhou Central Hospital, Xuzhou Institute of Medical Sciences, Xuzhou Clinical School of Nanjing Medical University, Affiliated Hospital of Medical School of Southeast University, Xuzhou, Jiangsu, China
| | - Ben Wang
- Department of Endocrinology, Xuzhou Central Hospital, Xuzhou Institute of Medical Sciences, Xuzhou Clinical School of Nanjing Medical University, Affiliated Hospital of Medical School of Southeast University, Xuzhou, Jiangsu, China
| | - Qinqin Qiu
- Department of Endocrinology, Xuzhou Central Hospital, Xuzhou Institute of Medical Sciences, Xuzhou Clinical School of Nanjing Medical University, Affiliated Hospital of Medical School of Southeast University, Xuzhou, Jiangsu, China
| | - Tianpei Yu
- Department of Endocrinology, Xuzhou Central Hospital, Xuzhou Institute of Medical Sciences, Xuzhou Clinical School of Nanjing Medical University, Affiliated Hospital of Medical School of Southeast University, Xuzhou, Jiangsu, China
| | - Yiquan Sang
- Department of Endocrinology, Xuzhou Central Hospital, Xuzhou Institute of Medical Sciences, Xuzhou Clinical School of Nanjing Medical University, Affiliated Hospital of Medical School of Southeast University, Xuzhou, Jiangsu, China
| | - Liying Wang
- Department of Endocrinology, Xuzhou Central Hospital, Xuzhou Institute of Medical Sciences, Xuzhou Clinical School of Nanjing Medical University, Affiliated Hospital of Medical School of Southeast University, Xuzhou, Jiangsu, China
| | - Jun Liang
- The Xuzhou Clinical College of Xuzhou Medical University, Xuzhou, Jiangsu, China.
- Department of Endocrinology, Xuzhou Central Hospital, Xuzhou Institute of Medical Sciences, Xuzhou Clinical School of Nanjing Medical University, Affiliated Hospital of Medical School of Southeast University, Xuzhou, Jiangsu, China.
| | - Wei Xu
- The Xuzhou Clinical College of Xuzhou Medical University, Xuzhou, Jiangsu, China.
- Department of Endocrinology, Xuzhou Central Hospital, Xuzhou Institute of Medical Sciences, Xuzhou Clinical School of Nanjing Medical University, Affiliated Hospital of Medical School of Southeast University, Xuzhou, Jiangsu, China.
| |
Collapse
|
3
|
Li M, Wu J, Geng W, Gao P, Yang Y, Li X, Xu K, Liao Q, Cai K. Interaction pathways of implant metal localized corrosion and macrophage inflammatory reactions. Bioact Mater 2024; 31:355-367. [PMID: 37663618 PMCID: PMC10474585 DOI: 10.1016/j.bioactmat.2023.08.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 07/29/2023] [Accepted: 08/19/2023] [Indexed: 09/05/2023] Open
Abstract
Macrophages play a central role in immunological responses to metallic species associated with the localized corrosion of metallic implants, and mediating in peri-implant inflammations. Herein, the pathways of localized corrosion-macrophage interactions were systematically investigated on 316L stainless steel (SS) implant metals. Electrochemical monitoring under macrophage-mediated inflammatory conditions showed a decreased pitting corrosion resistance of 316L SSs in the presence of RAW264.7 cells as the cells would disrupt biomolecule adsorbed layer on the metal surface. The pitting potentials were furtherly decreased when the RAW264.7 cells were induced to the M1 pro-inflammatory phenotype by the addition of lipopolysaccharide (LPS), and pitting corrosion preferentially initiated at the peripheries of macrophages. The overproduction of aggressive ROS under inflammatory conditions would accelerate the localized corrosion of 316L SS around macrophages. Under pitting corrosion condition, the viability and pro-inflammatory polarization of RAW264.7 cells were region-dependent, lower viability and more remarkable morphology transformation of macrophages in the pitting corrosion region than the pitting-free region. The pitting corrosion of 316L SS induced high expression of CD86, TNF-α, IL-6 and high level of intracellular ROS in macrophages. Uneven release of metallic species (Fe2+, Cr3+, Ni2+, etc) and uneven distribution of surface overpotential stimulated macrophage inflammatory responses near the corrosion pits. A synergetic effect of localized corrosion and macrophages was revealed, which could furtherly promote localized corrosion of 316L SS and macrophage inflammatory reactions. Our results provided direct evidence of corrosion-macrophage interaction in metallic implants and disclosed the pathways of this mutual stimulation effect.
Collapse
Affiliation(s)
- Meng Li
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, PR China
| | - Jing Wu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, PR China
| | - Wenbo Geng
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, PR China
| | - Pengfei Gao
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, PR China
| | - Yulu Yang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, PR China
| | - Xuan Li
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, PR China
| | - Kun Xu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, PR China
| | - Qiang Liao
- Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Chongqing University, Ministry of Education, School of Energy and Power Engineering, Chongqing, 400044, PR China
| | - Kaiyong Cai
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, PR China
| |
Collapse
|
4
|
Herbster M, Müller E, Jahn J, Buchholz A, Tootsi K, Lohmann CH, Halle T, Bertrand J. In vivo corrosion on retrieved hip endoprostheses and in vitro effects of corrosion products on bone mineralization. Bone 2023; 175:116852. [PMID: 37473933 DOI: 10.1016/j.bone.2023.116852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 07/14/2023] [Accepted: 07/17/2023] [Indexed: 07/22/2023]
Abstract
In vivo corrosion of modular endoprostheses remains a great concern, as the release of heavy metal ions can impair the implant's service life and the wellbeing of the patient. The detailed corrosion mechanisms that occur in vivo are so far not completely understood. In this context, the effects of implant released cobalt (Co) and chromium (Cr) ions on osteoblast mineralization and gene expression have not been investigated extensively. This comprehensive study aimed at furthering the understanding of in vivo implant corrosion from the clinical signs via prosthesis retrievals and histology of the synovial membranes down to the molecular processes instigated by corrosion products and its effects on bone mineralization. A detailed in vivo failure analysis was performed investigating 22 retrieved hip endoprostheses from different manufacturers and taper material combinations. The aim was to find a correlation of taper damage and especially corrosion to susceptible biomedical alloys and its effect on periprosthetic tissue as well as the clinical implant performance with regard to revision diagnosis and presence of radiolucent lines (RLL). A second part investigated the effects of Co and Cr ions on the in vitro mineralization process of osteoblasts. Cell cultures were exposed to relevant concentrations of CoCl2 and CrCl3 (0 μM, 100 μM, 200 μM) with and without addition of phosphate. Mineralization behavior was analyzed with Alizarin Red assay and Von Kossa staining of calcium depots, alkaline phosphatase activity of osteoblasts and gene expression was analyzed with real time quantitative PCR. The retrieval study provides evidence of in vivo fretting and crevice corrosion on all metallic tapers combined with either ceramic or metal femoral heads. Within the modular taper junctions, selective dissolution of the α phase occurred in wrought TiAl6V4 alloys, and etching of the fine-grained wrought CoCr28Mo6 alloy implants was observed in formed crevices. In addition, significant amounts of wear particles and corrosion products were detected in retrieved synovial membranes. An increased risk for the occurrence of a RLL in the proximal zones was determined for patients with a corroded mixed metal taper. Whereas Co ions have hardly any effects on mineralization, Cr ions cause a significant concentration dependent decrease in mineralization rate of osteoblasts. However, this effect is alleviated by addition of a phosphate source. Our data reveal that Cr ions depleted dissolved phosphates by forming an insoluble complex (CrPO4), which inhibits the phosphate dependent mineralization process. No significant effect of the heavy metal ions on osteoblast activity by means of alkaline phosphate activity as well as on gene expression is determined. This study broadens the understanding of in vivo corrosion of metallic modular implants and its clinically relevant effects on mineralization. Based on these findings, in vivo corrosion of CoCr28Mo6 endoprostheses should be limited to avoid inhibitory effects of Cr3+ on bone mineralization which can contribute to premature implant failure.
Collapse
Affiliation(s)
- Maria Herbster
- Institute of Materials and Joining Technology, Otto-von-Guericke University Magdeburg, Germany.
| | - Eva Müller
- Department of Orthopedic Surgery, Otto-von-Guericke University Magdeburg, Germany
| | - Jannik Jahn
- Department of Orthopedic Surgery, Otto-von-Guericke University Magdeburg, Germany
| | - Adrian Buchholz
- Department of Orthopedic Surgery, Otto-von-Guericke University Magdeburg, Germany
| | - Kaspar Tootsi
- Department of Orthopedic Surgery, Otto-von-Guericke University Magdeburg, Germany; Department of Traumatology and Orthopedics, University of Tartu, Tartu University Hospital, Tartu, Estonia
| | - Christoph H Lohmann
- Department of Orthopedic Surgery, Otto-von-Guericke University Magdeburg, Germany
| | - Thorsten Halle
- Institute of Materials and Joining Technology, Otto-von-Guericke University Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopedic Surgery, Otto-von-Guericke University Magdeburg, Germany
| |
Collapse
|
5
|
Yang J, Liu C, Sun H, Liu Y, Liu Z, Zhang D, Zhao G, Wang Q, Yang D. The progress in titanium alloys used as biomedical implants: From the view of reactive oxygen species. Front Bioeng Biotechnol 2022; 10:1092916. [PMID: 36601391 PMCID: PMC9806234 DOI: 10.3389/fbioe.2022.1092916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 12/07/2022] [Indexed: 12/23/2022] Open
Abstract
Titanium and Titanium alloys are widely used as biomedical implants in oral and maxillofacial surgery, due to superior mechanical properties and biocompatibility. In specific clinical populations such as the elderly, diabetics and patients with metabolic diseases, the failure rate of medical metal implants is increased significantly, putting them at increased risk of revision surgery. Many studies show that the content of reactive oxygen species (ROS) in the microenvironment of bone tissue surrounding implant materials is increased in patients undergoing revision surgery. In addition, the size and shape of materials, the morphology, wettability, mechanical properties, and other properties play significant roles in the production of ROS. The accumulated ROS break the original balance of oxidation and anti-oxidation, resulting in host oxidative stress. It may accelerate implant degradation mainly by activating inflammatory cells. Peri-implantitis usually leads to a loss of bone mass around the implant, which tends to affect the long-term stability and longevity of implant. Therefore, a great deal of research is urgently needed to focus on developing antibacterial technologies. The addition of active elements to biomedical titanium and titanium alloys greatly reduce the risk of postoperative infection in patients. Besides, innovative technologies are developing new biomaterials surfaces conferring anti-infective properties that rely on the production of ROS. It can be considered that ROS may act as a messenger substance for the communication between the host and the implanted material, which run through the entire wound repair process and play a role that cannot be ignored. It is necessary to understand the interaction between oxidative stress and materials, the effects of oxidative stress products on osseointegration and implant life as well as ROS-induced bactericidal activity. This helps to facilitate the development of a new generation of well-biocompatible implant materials with ROS responsiveness, and ultimately prolong the lifespan of implants.
Collapse
Affiliation(s)
- Jun Yang
- School of Stomatology, Jiamusi University, Jiamusi, China,Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang, China
| | - Chang Liu
- School of Stomatology, Jiamusi University, Jiamusi, China,Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang, China
| | - Hui Sun
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang, China
| | - Ying Liu
- The Affiliated Taian City Central Hospital of Qingdao University, Taian, China
| | - Zhaogang Liu
- The Affiliated Taian City Central Hospital of Qingdao University, Taian, China
| | - Dan Zhang
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang, China,*Correspondence: Donghong Yang, ; Dan Zhang,
| | - Gang Zhao
- School of Stomatology, Jiamusi University, Jiamusi, China
| | - Qiang Wang
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang, China
| | - Donghong Yang
- School of Stomatology, Jiamusi University, Jiamusi, China,*Correspondence: Donghong Yang, ; Dan Zhang,
| |
Collapse
|
6
|
Khodaei T, Schmitzer E, Suresh AP, Acharya AP. Immune response differences in degradable and non-degradable alloy implants. Bioact Mater 2022; 24:153-170. [PMID: 36606252 PMCID: PMC9793227 DOI: 10.1016/j.bioactmat.2022.12.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 12/13/2022] [Accepted: 12/15/2022] [Indexed: 12/23/2022] Open
Abstract
Alloy based implants have made a great impact in the clinic and in preclinical research. Immune responses are one of the major causes of failure of these implants in the clinic. Although the immune responses toward non-degradable alloy implants are well documented, there is a poor understanding of the immune responses against degradable alloy implants. Recently, there have been several reports suggesting that degradable implants may develop substantial immune responses. This phenomenon needs to be further studied in detail to make the case for the degradable implants to be utilized in clinics. Herein, we review these new recent reports suggesting the role of innate and potentially adaptive immune cells in inducing immune responses against degradable implants. First, we discussed immune responses to allergen components of non-degradable implants to give a better overview on differences in the immune response between non-degradable and degradable implants. Furthermore, we also provide potential areas of research that can be undertaken that may shed light on the local and global immune responses that are generated in response to degradable implants.
Collapse
Affiliation(s)
- Taravat Khodaei
- Biomedical Engineering, School of Biological and Health System Engineering, Arizona State, University, Tempe, AZ, 85281, USA
| | - Elizabeth Schmitzer
- Biomedical Engineering, School of Biological and Health System Engineering, Arizona State, University, Tempe, AZ, 85281, USA
| | | | - Abhinav P. Acharya
- Biomedical Engineering, School of Biological and Health System Engineering, Arizona State, University, Tempe, AZ, 85281, USA,Biological Design, Arizona State University, Tempe, AZ, 85281, USA,Chemical Engineering, School for the Engineering of Matter, Transport, and Energy, Arizona State, University, Tempe, AZ, 85281, USA,Materials Science and Engineering, School for the Engineering of Matter, Transport, and Energy, Arizona State University, Tempe, AZ, 85281, USA,Center for Immunotherapy, Vaccines and Virotherapy, Arizona State University, Tempe, AZ, 85281, USA,Corresponding author. Biomedical Engineering, School of Biological and Health System Engineering, Arizona State, University, Tempe, AZ, 85281, USA.
| |
Collapse
|
7
|
Ma Y, Lin W, Ruan Y, Lu H, Fan S, Chen D, Huang Y, Zhang T, Pi J, Xu JF. Advances of Cobalt Nanomaterials as Anti-Infection Agents, Drug Carriers, and Immunomodulators for Potential Infectious Disease Treatment. Pharmaceutics 2022; 14:pharmaceutics14112351. [PMID: 36365168 PMCID: PMC9696703 DOI: 10.3390/pharmaceutics14112351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 10/19/2022] [Accepted: 10/27/2022] [Indexed: 11/06/2022] Open
Abstract
Infectious diseases remain the most serious public health issue, which requires the development of more effective strategies for infectious control. As a kind of ultra-trace element, cobalt is essential to the metabolism of different organisms. In recent decades, nanotechnology has attracted increasing attention worldwide due to its wide application in different areas, including medicine. Based on the important biological roles of cobalt, cobalt nanomaterials have recently been widely developed for their attractive biomedical applications. With advantages such as low costs in preparation, hypotoxicity, photothermal conversion abilities, and high drug loading ability, cobalt nanomaterials have been proven to show promising potential in anticancer and anti-infection treatment. In this review, we summarize the characters of cobalt nanomaterials, followed by the advances in their biological functions and mechanisms. More importantly, we emphatically discuss the potential of cobalt nanomaterials as anti-infectious agents, drug carriers, and immunomodulators for anti-infection treatments, which might be helpful to facilitate progress in future research of anti-infection therapy.
Collapse
Affiliation(s)
- Yuhe Ma
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan 523808, China
- Institute of Laboratory Medicine, School of Medical Technology, Guangdong Medical University, Dongguan 523808, China
| | - Wensen Lin
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan 523808, China
- Institute of Laboratory Medicine, School of Medical Technology, Guangdong Medical University, Dongguan 523808, China
| | - Yongdui Ruan
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan 523808, China
| | - Hongmei Lu
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan 523808, China
| | - Shuhao Fan
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan 523808, China
- Institute of Laboratory Medicine, School of Medical Technology, Guangdong Medical University, Dongguan 523808, China
| | - Dongsheng Chen
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan 523808, China
- Institute of Laboratory Medicine, School of Medical Technology, Guangdong Medical University, Dongguan 523808, China
| | - Yuhe Huang
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan 523808, China
- Institute of Laboratory Medicine, School of Medical Technology, Guangdong Medical University, Dongguan 523808, China
| | - Tangxin Zhang
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan 523808, China
- Dongguan Key Laboratory of Environmental Medicine, School of Public Health, Guangdong Medical University, Dongguan 523808, China
| | - Jiang Pi
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan 523808, China
- Institute of Laboratory Medicine, School of Medical Technology, Guangdong Medical University, Dongguan 523808, China
- Correspondence: (J.P.); (J.-F.X.)
| | - Jun-Fa Xu
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan 523808, China
- Institute of Laboratory Medicine, School of Medical Technology, Guangdong Medical University, Dongguan 523808, China
- Correspondence: (J.P.); (J.-F.X.)
| |
Collapse
|
8
|
A Review of Biomaterials and Associated Performance Metrics Analysis in Pre-Clinical Finite Element Model and in Implementation Stages for Total Hip Implant System. Polymers (Basel) 2022; 14:polym14204308. [PMID: 36297885 PMCID: PMC9607025 DOI: 10.3390/polym14204308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 10/01/2022] [Accepted: 10/06/2022] [Indexed: 11/30/2022] Open
Abstract
Total hip replacement (THR) is a common orthopedic surgery technique that helps thousands of individuals to live normal lives each year. A hip replacement replaces the shattered cartilage and bone with an implant. Most hip implants fail after 10–15 years. The material selection for the total hip implant systems is a major research field since it affects the mechanical and clinical performance of it. Stress shielding due to excessive contact stress, implant dislocation due to a large deformation, aseptic implant loosening due to the particle propagation of wear debris, decreased bone remodeling density due to the stress shielding, and adverse tissue responses due to material wear debris all contribute to the failure of hip implants. Recent research shows that pre-clinical computational finite element analysis (FEA) can be used to estimate four mechanical performance parameters of hip implants which are connected with distinct biomaterials: von Mises stress and deformation, micromotion, wear estimates, and implant fatigue. In vitro, in vivo, and clinical stages are utilized to determine the hip implant biocompatibility and the unfavorable local tissue reactions to different biomaterials during the implementation phase. This research summarizes and analyses the performance of the different biomaterials that are employed in total hip implant systems in the pre-clinical stage using FEA, as well as their performances in in vitro, in vivo, and in clinical studies, which will help researchers in gaining a better understanding of the prospects and challenges in this field.
Collapse
|
9
|
Tan X, Liao D, Rao C, Zhou L, Tan Z, Pan Y, Singh A, Kumar A, Liu J, Li B. Recent advances in nano-architectonics of metal-organic frameworks for chemodynamic therapy. J SOLID STATE CHEM 2022. [DOI: 10.1016/j.jssc.2022.123352] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
10
|
Experimental Investigation of Material Transfer on Bearings for Total Hip Arthroplasty—A Retrieval Study on Ceramic and Metallic Femoral Heads. J Clin Med 2022; 11:jcm11143946. [PMID: 35887710 PMCID: PMC9318345 DOI: 10.3390/jcm11143946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 06/17/2022] [Accepted: 07/05/2022] [Indexed: 11/17/2022] Open
Abstract
Metallic deposition is a commonly observed phenomenon on the surface of revised femoral heads in total hip arthroplasty and can lead to increased wear due to third bodies. In order to find out the origin and composition of the transfer material, 98 retrieved femoral heads of different materials were examined with regard to the cause of revision, localization, pattern and composition of the transfer material by energy dispersive X-ray spectroscopy. We found that in 53.1%, the deposition was mostly in the region of the equator and the adjacent pole of the femoral heads. The most common cause for revision of heads with metallic deposition was polyethylene wear (43.9%). Random stripes (44.9%), random patches (41.8%) and solid patches (35.7%) were most prevalent on retrieved femoral heads. Random patches were a typical pattern in ceramic-on-ceramic bearing couples. The solid patch frequently occurred in association with dislocation of the femoral head (55%). The elemental analysis of the depositions showed a variety of different materials. In most cases, titanium was an element of the transferred material (76.5%). In addition to metallic components, several non-metallic components were also detected, such as carbon (49%) or sulfur (4.1%). Many of the determined elements could be assigned with regard to their origin with the help of the associated revision cause. Since the depositions lead to an introduction of third-body particles and thus to increased wear, the depositions on the bearing surfaces should be avoided in any case.
Collapse
|
11
|
|
12
|
Riedel F, Aparicio-Soto M, Curato C, Thierse HJ, Siewert K, Luch A. Immunological Mechanisms of Metal Allergies and the Nickel-Specific TCR-pMHC Interface. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:10867. [PMID: 34682608 PMCID: PMC8535423 DOI: 10.3390/ijerph182010867] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 10/03/2021] [Accepted: 10/11/2021] [Indexed: 12/19/2022]
Abstract
Besides having physiological functions and general toxic effects, many metal ions can cause allergic reactions in humans. We here review the immune events involved in the mediation of metal allergies. We focus on nickel (Ni), cobalt (Co) and palladium (Pd), because these allergens are among the most prevalent sensitizers (Ni, Co) and immediate neighbors in the periodic table of the chemical elements. Co-sensitization between Ni and the other two metals is frequent while the knowledge on a possible immunological cross-reactivity using in vivo and in vitro approaches remains limited. At the center of an allergic reaction lies the capability of a metal allergen to form T cell epitopes that are recognized by specific T cell receptors (TCR). Technological advances such as activation-induced marker assays and TCR high-throughput sequencing recently provided new insights into the interaction of Ni2+ with the αβ TCR-peptide-major histocompatibility complex (pMHC) interface. Ni2+ functionally binds to the TCR gene segment TRAV9-2 or a histidine in the complementarity determining region 3 (CDR3), the main antigen binding region. Thus, we overview known, newly identified and hypothesized mechanisms of metal-specific T cell activation and discuss current knowledge on cross-reactivity.
Collapse
Affiliation(s)
- Franziska Riedel
- Department for Chemicals and Product Safety, Federal Institute for Risk Assessment, Max-Dohrn-Straße 8-10, 10589 Berlin, Germany; (M.A.-S.); (C.C.); (H.-J.T.); (K.S.); (A.L.)
- Institute of Pharmacy, Freie Universität Berlin, Königin-Luise-Straße 2, 14195 Berlin, Germany
| | - Marina Aparicio-Soto
- Department for Chemicals and Product Safety, Federal Institute for Risk Assessment, Max-Dohrn-Straße 8-10, 10589 Berlin, Germany; (M.A.-S.); (C.C.); (H.-J.T.); (K.S.); (A.L.)
| | - Caterina Curato
- Department for Chemicals and Product Safety, Federal Institute for Risk Assessment, Max-Dohrn-Straße 8-10, 10589 Berlin, Germany; (M.A.-S.); (C.C.); (H.-J.T.); (K.S.); (A.L.)
| | - Hermann-Josef Thierse
- Department for Chemicals and Product Safety, Federal Institute for Risk Assessment, Max-Dohrn-Straße 8-10, 10589 Berlin, Germany; (M.A.-S.); (C.C.); (H.-J.T.); (K.S.); (A.L.)
| | - Katherina Siewert
- Department for Chemicals and Product Safety, Federal Institute for Risk Assessment, Max-Dohrn-Straße 8-10, 10589 Berlin, Germany; (M.A.-S.); (C.C.); (H.-J.T.); (K.S.); (A.L.)
| | - Andreas Luch
- Department for Chemicals and Product Safety, Federal Institute for Risk Assessment, Max-Dohrn-Straße 8-10, 10589 Berlin, Germany; (M.A.-S.); (C.C.); (H.-J.T.); (K.S.); (A.L.)
- Institute of Pharmacy, Freie Universität Berlin, Königin-Luise-Straße 2, 14195 Berlin, Germany
| |
Collapse
|
13
|
Moran MM, Wilson BM, Li J, Engen PA, Naqib A, Green SJ, Virdi AS, Plaas A, Forsyth CB, Keshavarzian A, Sumner DR. The gut microbiota may be a novel pathogenic mechanism in loosening of orthopedic implants in rats. FASEB J 2020; 34:14302-14317. [PMID: 32931052 DOI: 10.1096/fj.202001364r] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 07/29/2020] [Accepted: 08/07/2020] [Indexed: 01/08/2023]
Abstract
Particles released from implants cause inflammatory bone loss, which is a key factor in aseptic loosening, the most common reason for joint replacement failure. With the anticipated increased incidence of total joint replacement in the next decade, implant failure will continue to burden patients. The gut microbiome is increasingly recognized as an important factor in bone physiology, however, its role in implant loosening is currently unknown. We tested the hypothesis that implant loosening is associated with changes in the gut microbiota in a preclinical model. When the particle challenge caused local joint inflammation, decreased peri-implant bone volume, and decreased implant fixation, the gut microbiota was affected. When the particle challenge did not cause this triad of local effects, the gut microbiota was not affected. Our results suggest that cross-talk between these compartments is a previously unrecognized mechanism of failure following total joint replacement.
Collapse
Affiliation(s)
- Meghan M Moran
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL, USA
| | - Brittany M Wilson
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL, USA
| | - Jun Li
- Department of Internal Medicine, Division of Rheumatology, Rush Medical College, Rush University Medical Center, Chicago, IL, USA
| | - Phillip A Engen
- Department of Internal Medicine, Division of Digestive Diseases and Nutrition, Rush Medical College, Chicago, IL, USA
| | - Ankur Naqib
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL, USA.,Department of Internal Medicine, Division of Digestive Diseases and Nutrition, Rush Medical College, Chicago, IL, USA
| | - Stefan J Green
- Genome Research Core, Research Resources Center, University of Illinois-Chicago, Chicago, IL, USA
| | - Amarjit S Virdi
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL, USA
| | - Anna Plaas
- Department of Internal Medicine, Division of Rheumatology, Rush Medical College, Rush University Medical Center, Chicago, IL, USA
| | - Christopher B Forsyth
- Department of Internal Medicine, Division of Digestive Diseases and Nutrition, Rush Medical College, Chicago, IL, USA
| | - Ali Keshavarzian
- Department of Internal Medicine, Division of Digestive Diseases and Nutrition, Rush Medical College, Chicago, IL, USA
| | - Dale R Sumner
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
14
|
Laumonier T, Ruffieux E, Paccaud J, Kindler V, Hannouche D. In vitro evaluation of human myoblast function after exposure to cobalt and chromium ions. J Orthop Res 2020; 38:1398-1406. [PMID: 31883135 DOI: 10.1002/jor.24579] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Accepted: 12/23/2019] [Indexed: 02/04/2023]
Abstract
The replacement of a native hip joint by a metal-on-metal prosthesis may induce deleterious inflammatory side effects that are associated with the release of wear particles and metal ions. These events are referred to the adverse reaction to metal debris (ARMD) and the adverse local tissue reaction (ALTR). While wear particles seem involved in ARMD, the role of metal ions in ALTR and their impact on myoblasts, located in the prosthesis vicinity, has not been fully identified. To clarify this issue we investigated, using an in vitro culture system, the effect of cobalt and/or chromium ions (Co2+ and/or Cr3+ ) on human myoblast proliferation, cellular differentiation, and inflammatory marker expression. Freshly isolated human myoblasts were cultured in media supplemented with graded concentrations of Co2+ and/or Cr3+ . Co2+ induced a concentration-dependent decrease of both myoblast viability and myogenic differentiation while Cr3+ did not. Co2+ or Co2+ /Cr3+ also induced the upregulation of ICAM-1, whereas HLA-DR expression was unaffected. Moreover, allogenic monocytes induced the synergistic increase of Co2+ -induced ICAM-1 expression. We also found that Co2+ stabilized HIF-1α and increased TLR4, tumor necrosis factor-alpha (TNF-α), and interleukin 1β (IL-1β) expression in a dose and time-dependent manner in human myoblasts. This study showed that Co2+ , but not Cr3+ , was toxic toward myoblasts and induced, in the surviving cells, expression of inflammatory markers such as ICAM-1, TLR4, TNF-α, and IL-1β. This suggests that Co2+ , most efficiently in the presence of monocytes, may be a key inducer of ALTR, which may, if severe and long-lasting, eventually result in prosthesis loosening.
Collapse
Affiliation(s)
- Thomas Laumonier
- Department of Orthopedic Surgery, Faculty of Medicine, Geneva University Hospitals, Geneva, Switzerland
| | - Etienne Ruffieux
- Department of Orthopedic Surgery, Faculty of Medicine, Geneva University Hospitals, Geneva, Switzerland
| | - Joris Paccaud
- Department of Orthopedic Surgery, Faculty of Medicine, Geneva University Hospitals, Geneva, Switzerland
| | - Vincent Kindler
- Department of Orthopedic Surgery, Faculty of Medicine, Geneva University Hospitals, Geneva, Switzerland
| | - Didier Hannouche
- Department of Orthopedic Surgery, Faculty of Medicine, Geneva University Hospitals, Geneva, Switzerland
| |
Collapse
|
15
|
Antiproliferative, DNA binding, and cleavage properties of dinuclear Co(III) complexes containing the bioactive quinizarin ligand. J Biol Inorg Chem 2020; 25:339-350. [DOI: 10.1007/s00775-020-01765-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Accepted: 02/12/2020] [Indexed: 01/23/2023]
|
16
|
Biological Reactions to Metal Particles and Ions in the Synovial Layer of Mice. MATERIALS 2020; 13:ma13051044. [PMID: 32110869 PMCID: PMC7084385 DOI: 10.3390/ma13051044] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Revised: 02/21/2020] [Accepted: 02/24/2020] [Indexed: 12/16/2022]
Abstract
Metal particles and ions released from implants not only have a fundamental effect on the longevity of total joint replacements, but can also be disseminated to remote organs. Periprosthetic tissues harvested during revision surgeries mainly reflect end-stage failure but may not adequately reveal initial biological reactions and systemic side effects. Therefore, primary reactions caused by metal particles and ions were investigated in an established murine model. Left knee joints in three groups, each consisting of ten female BALB/c mice, received injections of metal ions (MI), metal particles (MP) and phosphate-buffered saline (PBS) (control). Seven days after the injection, immunohistochemical analyses of the synovial layer were performed with respect to some biological markers including Tumor necrosis factor -α (TNF-α), Interleukin-6 (IL-6), Interleukin-1β (IL-1β), Cluster of Differentiation 45 (CD45), Cluster of Differentiation 68 (CD68) and Cluster of Differentiation 3(CD3). The MP group showed significantly enhanced proinflammatory cytokine expression (TNF-α, IL-6 and IL-1β) compared with the other groups (p < 0.05). Interestingly, CD3, as a marker for T lymphocytes, did not increase in any of the groups. The MI group showed a significantly increased expression of CD45 compared with the control group (p < 0.05). Therefore, during the primary process, metal particles have stronger pro-inflammatory potential than metal ions, and T lymphocytes did not seem to be activated in our murine model. Systemic reactions caused by metal particles and ions were found by observing the untreated right knees.
Collapse
|
17
|
Hameister R, Kaur C, Dheen ST, Lohmann CH, Singh G. Reactive oxygen/nitrogen species (ROS/RNS) and oxidative stress in arthroplasty. J Biomed Mater Res B Appl Biomater 2020; 108:2073-2087. [PMID: 31898397 DOI: 10.1002/jbm.b.34546] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 11/19/2019] [Accepted: 12/08/2019] [Indexed: 12/16/2022]
Abstract
The interplay between implant design, biomaterial characteristics, and the local microenvironment adjacent to the implant is of utmost importance for implant performance and success of the joint replacement surgery. Reactive oxygen and nitrogen species (ROS/RNS) are among the various factors affecting the host as well as the implant components. Excessive formation of ROS and RNS can lead to oxidative stress, a condition that is known to damage cells and tissues and also to affect signaling pathways. It may further compromise implant longevity by accelerating implant degradation, primarily through activation of inflammatory cells. In addition, wear products of metallic, ceramic, polyethylene, or bone cement origin may also generate oxidative stress themselves. This review outlines the generation of free radicals and oxidative stress in arthroplasty and provides a conceptual framework on its implications for soft tissue remodeling and bone resorption (osteolysis) as well as implant longevity. Key findings derived from cell culture studies, animal models, and patients' samples are presented. Strategies to control oxidative stress by implant design and antioxidants are explored and areas of controversy and challenges are highlighted. Finally, directions for future research are identified. A better understanding of the host-implant interplay and the role of free radicals and oxidative stress will help to evaluate therapeutic approaches and will ultimately improve implant performance in arthroplasty.
Collapse
Affiliation(s)
- Rita Hameister
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Charanjit Kaur
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Shaikali Thameem Dheen
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Gurpal Singh
- Centre for Orthopaedics Pte Ltd, Singapore, Singapore
| |
Collapse
|
18
|
Eltit F, Wang Q, Wang R. Mechanisms of Adverse Local Tissue Reactions to Hip Implants. Front Bioeng Biotechnol 2019; 7:176. [PMID: 31417898 PMCID: PMC6683860 DOI: 10.3389/fbioe.2019.00176] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 07/08/2019] [Indexed: 12/11/2022] Open
Abstract
Adverse Local Tissue Reactions (ALTRs) are one of the main causes of hip implant failures. Although the metal release from the implants is considered as a main etiology, the mechanisms, and the roles of the released products are topics of ongoing research. The alloys used in the hip implants are considered biocompatible and show negligible corrosion in the body environment under static conditions. However, modularity and its associated mechanically assisted corrosion have been shown to release metal species into the body fluids. ALTRs associated with metal release have been observed in hip implants with metal-on-metal articulation initially, and later with metal-on-polyethylene articulation, the most commonly used design in current hip replacement. The etiological factors in ALTRs have been the topics of many studies. One commonly accepted theory is that the interactions between the metal species and body proteins and cells generate a delayed type IV hypersensitivity reaction leading to ALTRs. However, lymphocyte reactions are not always observed in ALTRS, and the molecular mechanisms have not been clearly demonstrated. A more accepted mechanism is that cell damage generated by metal ions may trigger the secretion of cytokines leading to the inflammatory reactions observed in ALTRs. In this inflammatory environment, some patients would develop hypersensitivity that is associated with poor outcomes. Concerns over ALTRS have brought significant impact to both the clinical selection and development of hip implants. This review is focused on the mechanisms of ALTRs, specifically, the metal release process and the roles of the metal species released in the etiology and pathogenesis of the disease. Hopefully, our presentation and discussion of this biological process from a material perspective could improve our current understanding on the ALTRs and provide useful guidance in developing preventive solutions.
Collapse
Affiliation(s)
- Felipe Eltit
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Qiong Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Rizhi Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| |
Collapse
|