1
|
Huertas-López A, Martínez-Subiela S, Cerón JJ, Vázquez-Calvo Á, Pazmiño-Bonilla ED, López-Ureña NM, Martínez-Carrasco C, Álvarez-García G. Development and validation of a time-resolved fluorescence immunoassay for the detection of anti-Toxoplasma gondii antibodies in goats. Vet Parasitol 2021; 293:109432. [PMID: 33915322 DOI: 10.1016/j.vetpar.2021.109432] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Revised: 04/17/2021] [Accepted: 04/18/2021] [Indexed: 11/29/2022]
Abstract
Toxoplasma gondii is a worldwide distributed parasite causing abortions and fetal malformations in small ruminants. The aim of this study was to design and validate a new immunoassay based on the use of TgSAG1-GRA8 chimeric antigen for the detection of anti-T. gondii antibodies in serum of goats. First, a time-resolved fluorescence immunoassay (TgSAG1-GRA8-TRFIA) was developed. In addition, the diagnostic performance of TgSAG1-GRA8-TRFIA was compared with an optimized enzyme-linked immunosorbent assay (TgSALUVET-ELISA) and a Western Blot (WB), both based on whole T. gondii tachyzoite antigenic extract. The TgSAG1-GRA8-TRFIA has shown a high intra- and inter-assay precision, analytical sensitivity and accuracy. The ROC analysis of this assay showed an optimal cut-off of 217.4 Units of Fluorometry for T. gondii (UFT), with 92 % of sensitivity and 90.48 % of specificity. A positive and statistically significant Spearman's correlation with TgSALUVET-ELISA was detected, and kappa value was 0.83, presenting high agreement with both methods. However, TgSAG1-GRA8 protein showed cross-reactivity with specific anti-Neospora caninum antibodies. Thus, TgSAG-1-GRA8 chimeric antigen seems not to be an ideal option for the serodiagnosis of T. gondii infection in goats unless combined with the serodiagnosis of N. caninum infection in parallel. In the light of the results obtained, a comprehensive study on the existence of cross-reactivities between T. gondii antigens used in serological tests employed in animal health and specific antibodies directed against Toxoplasmatinae parasites should be performed.
Collapse
Affiliation(s)
- Ana Huertas-López
- Interdisciplinary Laboratory of Clinical Analysis, Interlab-UMU, University of Murcia, 30100, Espinardo, Murcia, Spain
| | - Silvia Martínez-Subiela
- Interdisciplinary Laboratory of Clinical Analysis, Interlab-UMU, University of Murcia, 30100, Espinardo, Murcia, Spain
| | - José Joaquín Cerón
- Interdisciplinary Laboratory of Clinical Analysis, Interlab-UMU, University of Murcia, 30100, Espinardo, Murcia, Spain
| | | | | | - Nadia María López-Ureña
- Department of Animal Health, Complutense University of Madrid, Ciudad Universitaria s/n, 28040, Madrid, Spain
| | | | - Gema Álvarez-García
- Department of Animal Health, Complutense University of Madrid, Ciudad Universitaria s/n, 28040, Madrid, Spain
| |
Collapse
|
2
|
Omar NAS, Fen YW, Ramli I, Sadrolhosseini AR, Abdullah J, Yusof NA, Kamil YM, Mahdi MA. An Optical Sensor for Dengue Envelope Proteins Using Polyamidoamine Dendrimer Biopolymer-Based Nanocomposite Thin Film: Enhanced Sensitivity, Selectivity, and Recovery Studies. Polymers (Basel) 2021; 13:762. [PMID: 33671059 PMCID: PMC7957696 DOI: 10.3390/polym13050762] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 02/18/2021] [Accepted: 02/20/2021] [Indexed: 11/16/2022] Open
Abstract
This paper proposes a novel idea to enhance the sensitivity and selectivity of surface plasmon resonance (SPR) optical sensor for detection of dengue virus type-2 envelope proteins (DENV-2 E-proteins) using polyamidoamine (PAMAM) dendrimer biopolymer-based nanocomposite thin film. For this purpose, two ranges of DENV-2 E-protein concentrations, i.e., 0.000008-0.0001 nM and 0.00008-0.005 nM were evaluated, and the lowest detectable concentration was achieved at 0.00008 nM. The incorporation of PAMAM dendrimer-based nanocomposite thin film with an SPR sensor exhibited a significant increase in sensitivity and binding affinity to a lower range DENV-2 E-protein concentrations. Moreover, the proposed sensor displayed good selectivity towards DENV-2 E-proteins and have an average recovery of 80-120%. The findings of this study demonstrated that PAMAM dendrimer-based nanocomposite thin film combined with SPR sensor is a promising diagnostic tool for sensitive and selective detection of DENV-2 E-proteins.
Collapse
Affiliation(s)
- Nur Alia Sheh Omar
- Faculty of Science, Universiti Putra Malaysia, UPM Serdang 43400, Selangor, Malaysia; (N.A.S.O.); (I.R.); (J.A.); (N.A.Y.)
- Institute of Advanced Technology, Universiti Putra Malaysia, UPM Serdang 43400, Selangor, Malaysia;
| | - Yap Wing Fen
- Faculty of Science, Universiti Putra Malaysia, UPM Serdang 43400, Selangor, Malaysia; (N.A.S.O.); (I.R.); (J.A.); (N.A.Y.)
- Institute of Advanced Technology, Universiti Putra Malaysia, UPM Serdang 43400, Selangor, Malaysia;
| | - Irmawati Ramli
- Faculty of Science, Universiti Putra Malaysia, UPM Serdang 43400, Selangor, Malaysia; (N.A.S.O.); (I.R.); (J.A.); (N.A.Y.)
| | - Amir Reza Sadrolhosseini
- Institute of Advanced Technology, Universiti Putra Malaysia, UPM Serdang 43400, Selangor, Malaysia;
| | - Jaafar Abdullah
- Faculty of Science, Universiti Putra Malaysia, UPM Serdang 43400, Selangor, Malaysia; (N.A.S.O.); (I.R.); (J.A.); (N.A.Y.)
| | - Nor Azah Yusof
- Faculty of Science, Universiti Putra Malaysia, UPM Serdang 43400, Selangor, Malaysia; (N.A.S.O.); (I.R.); (J.A.); (N.A.Y.)
- Institute of Advanced Technology, Universiti Putra Malaysia, UPM Serdang 43400, Selangor, Malaysia;
| | - Yasmin Mustapha Kamil
- inLAZER Dynamics Sdn Bhd, InnoHub Unit, Putra Science Park, Universiti Putra Malaysia, UPM Serdang 43400, Selangor, Malaysia;
| | - Mohd Adzir Mahdi
- Wireless and Photonics Network Research Centre, Faculty of Engineering, Universiti Putra Malaysia, UPM Serdang 43400, Selangor, Malaysia;
| |
Collapse
|
3
|
A time-resolved fluorescence immunoassay for the detection of anti-Neospora caninum antibodies in sheep. Vet Parasitol 2019; 276:108994. [PMID: 31778941 DOI: 10.1016/j.vetpar.2019.108994] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2019] [Revised: 11/14/2019] [Accepted: 11/18/2019] [Indexed: 11/22/2022]
Abstract
Neospora caninum is a protozoan parasite (Phylum Apicomplexa) that has been recently suggested as a relevant cause of reproductive disorders in small ruminants. The aim of the present study is to develop and validate a new serological test based on time resolved fluorescency using N. caninum GRA7 recombinant antigen (GRA7-TRFIA) for the detection of N. caninum antibodies in sheep. A total of 346 serum samples (208 from experimentally infected sheep, 117 from a dairy farm with a previous history of Neospora-associated abortion, and 21 negative sera) were used. The validation of the new assay was performed by the evaluation of assay precision, analytical sensitivity (Se), accuracy and cross reactivity. In the experimentally infected sheep, antibody kinetics was compared between GRA7-TRFIA and an in house N. caninum tachyzoite soluble extract-based ELISA (NcSALUVET ELISA) by Wilcoxon matched-pairs signed rank test. The cut-off and diagnostic Se and specificity (Sp) of GRA7-TRFIA was estimated by ROC analysis with field samples. In addition, concordance and correlation between GRA7-TRFIA and a commercial ELISA and NcSALUVET ELISA were assessed by kappa value and Spearman correlation coefficient, respectively. Overall, GRA7-TRFIA showed an adequate precision, analytical Se and accuracy to detect anti-N. caninum antibodies in ovine serum, and no cross reactivity with the closely related protozoan Toxoplasma gondii. In naturally infected sheep, 100% Se and 95.35% Sp were obtained for a cut-off point of 62.68 Units of Fluorometry for N. caninum (UFN). Moreover, GRA7-TRFIA allowed earlier detection of N. caninum infection than NcSALUVET ELISA in experimentally infected sheep.
Collapse
|
4
|
Prediction value of serum HBV large surface protein in different phases of HBV infection and virological response of chronic hepatitis B patients. Clin Chim Acta 2018; 481:12-19. [PMID: 29453971 DOI: 10.1016/j.cca.2018.02.015] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2017] [Revised: 02/13/2018] [Accepted: 02/13/2018] [Indexed: 12/18/2022]
Abstract
BACKGROUND Serum HBV large surface protein (HBV-LP) is an envelope protein that has a close relationship with HBV DNA level. This study is to explore the prediction value of HBV-LP in different phase of HBV infection and during antiviral therapy in chronic hepatitis B (CHB) patients. METHODS A retrospective study was conducted in 2033 individuals, which included 1677 HBV infected patients in different phases and 356 healthy controls. HBV-LP, HBV serum markers and HBV DNA were detected by ELISA, CMIA and qRT-PCR, respectively. 85 CHB patients receiving PegIFNα or ETV were divided into virological response (VR) and partial virological response (PVR). The dynamic changes of HBV DNA and HBV-LP were observed. RESULTS The level of HBV-LP in 2033 individuals was shown as: HBeAg-positive hepatitis > HBeAg-positive infection > HBeAg-negative hepatitis > HBeAg-negative infection > healthy controls. HBV-LP was positive in all patients whose HBV DNA > 1.0E + 06 IU/ml. When HBsAg was <0.05 IU/ml or >1000 IU/ml, HBV DNAs were all negative if HBV-LP < 1.0 S/CO. When HBsAg was between 0.05 IU/ml and 1000 IU/ml, the consistency of HBV-LP with HBV DNA was 100% in case of HBV-LP > 4.0 S/CO in HBeAg-positive patients and HBV-LP > 2.0 S/CO in HBeAg-negative ones. During antiviral therapy, baseline HBV-LP was lower in VR patients than that in PVR patients. The optimal cut-off points to predict VR by baseline HBV-LP were 32.4 and 28.6 S/CO for HBeAg-positive and HBeAg-negative hepatitis patients, respectively. CONCLUSIONS HBV-LP may be a useful marker for distinguishing the different phases of HBV infection. Moreover, baseline HBV-LP level can be used for predicting VR of CHB patients.
Collapse
|
5
|
New wide dynamic range assays for quantification of anti- Leishmania IgG2 and IgA antibodies in canine serum. Vet Immunol Immunopathol 2017; 189:11-16. [DOI: 10.1016/j.vetimm.2017.05.007] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2016] [Revised: 05/17/2017] [Accepted: 05/25/2017] [Indexed: 12/15/2022]
|
6
|
Cantos-Barreda A, Escribano D, Bernal LJ, Cerón JJ, Martínez-Subiela S. Quantification of anti-Leishmania antibodies in saliva of dogs. Vet Parasitol 2017; 242:54-58. [PMID: 28606325 DOI: 10.1016/j.vetpar.2017.05.017] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2017] [Revised: 04/05/2017] [Accepted: 05/19/2017] [Indexed: 10/19/2022]
Abstract
Detection of serum anti-Leishmania antibodies by quantitative or qualitative techniques has been the most used method to diagnose Canine Leishmaniosis (CanL). Nevertheless, saliva may represent an alternative to blood because it is easy to collect, painless and non-invasive in comparison with serum. In this study, two time-resolved immunofluorometric assays (TR-IFMAs) for quantification of anti-Leishmania IgG2 and IgA antibodies in saliva were developed and validated and their ability to distinguish Leishmania-seronegative from seropositive dogs was evaluated. The analytical study was performed by evaluation of assay precision, sensitivity and accuracy. In addition, serum from 48 dogs (21 Leishmania-seropositive and 27 Leishmania-seronegative) were analyzed by TR-IFMAs. The assays were precise, with an intra- and inter-assay coefficients of variation lower than 11%, and showed high level of accuracy, as determined by linearity under dilution (R2=0.99) and recovery tests (>88.60%). Anti-Leishmania IgG2 antibodies in saliva were significantly higher in the seropositive group compared with the seronegative (p<0.0001), whereas no significant differences for anti-Leishmania IgA antibodies between both groups were observed. Furthermore, TR-IFMA for quantification of anti-Leishmania IgG2 antibodies in saliva showed higher differences between seropositive and seronegative dogs than the commercial assay used in serum. In conclusion, TR-IFMAs developed may be used to quantify anti-Leishmania IgG2 and IgA antibodies in canine saliva with an adequate precision, analytical sensitivity and accuracy. Quantification of anti-Leishmania IgG2 antibodies in saliva could be potentially used to evaluate the humoral response in CanL. However, IgA in saliva seemed not to have diagnostic value for this disease. For future studies, it would be desirable to evaluate the ability of the IgG2 assay to detect dogs with subclinical disease or with low antibody titers in serum and also to study the antibodies behaviour in saliva during the treatment of CanL.
Collapse
Affiliation(s)
- Ana Cantos-Barreda
- Interdisciplinary Laboratory of Clinical Analysis, Interlab-UMU, Regional Campus of International Excellence "Campus Mare Nostrum", University of Murcia, Espinardo, Murcia, Spain
| | - Damián Escribano
- Interdisciplinary Laboratory of Clinical Analysis, Interlab-UMU, Regional Campus of International Excellence "Campus Mare Nostrum", University of Murcia, Espinardo, Murcia, Spain
| | - Luis J Bernal
- Interdisciplinary Laboratory of Clinical Analysis, Interlab-UMU, Regional Campus of International Excellence "Campus Mare Nostrum", University of Murcia, Espinardo, Murcia, Spain
| | - José J Cerón
- Interdisciplinary Laboratory of Clinical Analysis, Interlab-UMU, Regional Campus of International Excellence "Campus Mare Nostrum", University of Murcia, Espinardo, Murcia, Spain.
| | - Silvia Martínez-Subiela
- Interdisciplinary Laboratory of Clinical Analysis, Interlab-UMU, Regional Campus of International Excellence "Campus Mare Nostrum", University of Murcia, Espinardo, Murcia, Spain
| |
Collapse
|