Vierling L, Liu CC, Wiedemeier D, Gubler A, Schmidlin PR. Assessing the Impact of Various Decontamination Instruments on Titanium and Zirconia Dental Implants: An In Vitro Study. Dent J (Basel) 2024; 12:136. [PMID: 38786534 PMCID: PMC11119916 DOI: 10.3390/dj12050136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 04/29/2024] [Accepted: 05/07/2024] [Indexed: 05/25/2024] Open
Abstract
This study investigates the impact of various instrumentation techniques on material removal and surface changes in titanium (Ti)- and zirconia (Zr) implant discs. Ti- and Zr discs were subjected to standardized experiments using various instruments including airflow, ultrasound, carbide, and diamond burs. Instrumentation was performed for 60 s with continuous automatic motion. Abrasion and changes in surface roughness were assessed using profilometry, while scanning electron microscopy was used to examine morphological changes and particle size. Carbide burs predominantly caused abrasion on Ti discs, while diamond burs caused more abrasion on Zr discs. The Ti discs were more susceptible to surface changes. However, among the materials tested, machined Zr discs treated with diamond burs produced the largest particle. In certain cases, a statistical significance (p < 0.05) was observed between the groups, while in others, there was no considerable difference among the means (p > 0.05). These results highlighted the statistical significance of our findings. These results found diverse alterations in surface characteristics of Ti- and Zr discs due to different instruments, with carbide and diamond burs causing notable effects. The findings highlight the need for a careful balance between promoting healing and minimizing harm during implantoplasty.
Collapse
Affiliation(s)
- Louisa Vierling
- Clinic of Conservative and Preventive Dentistry, Division of Periodontology and Peri-Implant Diseases, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (L.V.); (C.C.L.); (A.G.)
| | - Chun Ching Liu
- Clinic of Conservative and Preventive Dentistry, Division of Periodontology and Peri-Implant Diseases, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (L.V.); (C.C.L.); (A.G.)
| | - Daniel Wiedemeier
- Statistics Group, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland;
| | - Andrea Gubler
- Clinic of Conservative and Preventive Dentistry, Division of Periodontology and Peri-Implant Diseases, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (L.V.); (C.C.L.); (A.G.)
| | - Patrick R. Schmidlin
- Clinic of Conservative and Preventive Dentistry, Division of Periodontology and Peri-Implant Diseases, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (L.V.); (C.C.L.); (A.G.)
| |
Collapse
|
2
|
Kao A, Tawse-Smith A, Ma S, Duncan WJ, Reid M, Atieh MA. Quantity and Size of Titanium Particles Released from Different Mechanical Decontamination Procedures on Titanium Discs: An In Vitro Study. Dent J (Basel) 2024; 12:123. [PMID: 38786521 PMCID: PMC11119952 DOI: 10.3390/dj12050123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 04/11/2024] [Accepted: 04/17/2024] [Indexed: 05/25/2024] Open
Abstract
Complications such as peri-implantitis could ultimately affect the survival of a dental implant. The prevention and treatment of peri-implant diseases require managing bacterial biofilm and controlling environmental risks, including the presence of pro-inflammatory titanium (Ti) particles in the peri-implant niche. Objectives included the evaluation of the size and quantity of Ti particles released from moderately roughened Ti surfaces during common mechanical surface decontamination methods. One hundred and forty moderately roughened Ti discs were divided into seven groups (n = 20 per group); six groups received mechanical decontamination procedures (ultrasonic scaling (US) with a metal tip and poly-ether-ketone (PEEK) under low and medium power settings, air-polishing with erythritol powder, and Ti brush), and the control group underwent air-water spray using a dental triplex. The rinsing solution was collected for Ti mass analysis using inductively coupled plasma mass spectrometry (ICPMS), as well as for Ti particle size and count analysis under scanning electron microscopy (SEM) with energy-dispersive spectroscopy (EDS). US metal tip instrumentation generated 34.00 ± 12.54 μg and 34.44 ± 6.08 μg of Ti under low and medium power settings, respectively. This amount of Ti generation was significantly higher than other instrumentation methods. The mean Ti particle size of the US groups ranged from 0.89 ± 0.27 μm to 1.25 ± 0.24 μm. No statistically significant difference was found in the particle size among US groups and Ti brush group (1.05 ± 0.11 μm), except for US with the PEEK tip, where a significantly smaller mean particle diameter was found at the low power setting (0.89 ± 0.27 μm). Mechanical instrumentation can produce Ti particulates and modify the implant surfaces. US using a metal tip generated the highest amount of Ti with smaller Ti size particles compared to all other commonly used mechanical surface instrumentations. The EDS analysis confirmed Ti in PEEK US tips. It can be suggested that deterioration from the PEEK US tip and Ti brush, as observed under SEM, is an additional source of Ti release during Ti surface decontamination.
Collapse
Affiliation(s)
- Anthony Kao
- Sir John Walsh Research Institute, Faculty of Dentistry, 310 Great King Street, Dunedin 9016, New Zealand; (A.K.); (S.M.); (W.J.D.); (M.A.A.)
| | - Andrew Tawse-Smith
- Sir John Walsh Research Institute, Faculty of Dentistry, 310 Great King Street, Dunedin 9016, New Zealand; (A.K.); (S.M.); (W.J.D.); (M.A.A.)
| | - Sunyoung Ma
- Sir John Walsh Research Institute, Faculty of Dentistry, 310 Great King Street, Dunedin 9016, New Zealand; (A.K.); (S.M.); (W.J.D.); (M.A.A.)
| | - Warwick J. Duncan
- Sir John Walsh Research Institute, Faculty of Dentistry, 310 Great King Street, Dunedin 9016, New Zealand; (A.K.); (S.M.); (W.J.D.); (M.A.A.)
| | - Malcolm Reid
- Department of Chemistry and Centre for Trace Element Analysis, Department of Geology, Dunedin 9054, New Zealand;
| | - Momen A. Atieh
- Sir John Walsh Research Institute, Faculty of Dentistry, 310 Great King Street, Dunedin 9016, New Zealand; (A.K.); (S.M.); (W.J.D.); (M.A.A.)
- Department of Oral Diagnostics and Surgical Sciences, Hamdan Bin Mohammed College of Dental Medicine, Mohammed Bin Rashid University of Medicine and Health Sciences, Dubai P.O. Box 505055, United Arab Emirates
- School of Dentistry, University of Jordan, Amman 11942, Jordan
| |
Collapse
|
3
|
Lang LK, Karl M, Klär V. Evaluation of different debridement strategies for implant-abutment connections: An in vitro study. J Prosthet Dent 2023; 130:738.e1-738.e8. [PMID: 37739883 DOI: 10.1016/j.prosdent.2023.08.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 08/24/2023] [Accepted: 08/25/2023] [Indexed: 09/24/2023]
Abstract
STATEMENT OF PROBLEM Technical complications, including abutment fracture, are a clinical reality. After retrieving failed components, re-establishing a reliable implant-abutment connection is essential, but recommendations on how to clean the interface are lacking. PURPOSE The purpose of this in vitro study was to evaluate different clinical debridement strategies for removing titanium powder from an implant-abutment interface with regard to their efficacy and associated risk of damaging the interface. MATERIAL AND METHODS Specimens (n=5) were assembled from previously cut implant halves, which were then contaminated by placing titanium powder inside the implant-abutment connection. Activated rinsing, airflow, and an ultrasound scaler, as well as combinations thereof, were then used to clean the implant-abutment connections. Both parts of each specimen were rated under a light microscope with respect to contamination and damage. In addition, abutments were placed in intact implants (n=10), which had previously been contaminated and cleaned, to record torque curves and abutment stability. Statistical analysis of ratings was based on Kruskal-Wallis tests and the Nemenyi All Pairs test with single-step P value correction, while abutment stability and torque were analyzed using analysis of variance and Tukey HSD tests (α=.05). RESULTS Erythritol as an abrasive medium led to significantly greater contamination than the scaler (P=.002), activated rinsing (P=.021), and airflow with sodium bicarbonate combined with either conventional (P=.002) or activated rinsing (P=.007). Greater damage was also observed with erythritol because of accumulations of the abrasive media, while scratches were seen after scaler application. Airflow using sodium bicarbonate in combination with activated rinsing showed the lowest level of damage (versus scaler P=.030). Using conventional (P=.010) or activated (P=.029) rinsing, airflow treatment led to a significant reduction in contamination. The scaler led to a significant decrease in abutment stability (P=.048), while activated rinsing and the combination of airflow and activated rinsing did not significantly affect abutment stability. Abutments placed in implants previously contaminated and cleaned required greater torque as compared with original implants (versus activated rinsing, P=.009). CONCLUSIONS Activated rinsing constituted the best technique for cleaning implant-abutment connections. Cleaning efficiency can be enhanced with airflow using sodium bicarbonate as an abrasive medium.
Collapse
Affiliation(s)
- Lilly K Lang
- Graduate student, Department of Prosthodontics, Saarland University, Homburg, Saar, Germany
| | - Matthias Karl
- Professor and Director, Department of Prosthodontics, Saarland University, Homburg, Saar, Germany
| | - Virgilia Klär
- Research Associate, Department of Prosthodontics, Saarland University, Homburg, Saar, Germany..
| |
Collapse
|
4
|
AjitSankardas P, Stein SH, Tipton D, Abhyankar V, Morrow BR. Impact of Metal Particles Released during Ultrasonic Scaling of Titanium Surfaces on Human Gingival Fibroblasts. J Long Term Eff Med Implants 2022; 33:9-22. [PMID: 36382700 DOI: 10.1615/jlongtermeffmedimplants.2022043080] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
PURPOSE Metal particles found in tissues around dental implants have been proposed to play a pathogenic role in peri-implantitis. Ultrasonic scaling has been suggested as a mechanism by which these particles can be inadvertently released into surrounding tissues. Furthermore, risk factors like diabetes can result in exacerbation of this inflammatory condition. The current study aimed to analyze metal particles released from titanium surfaces during ultrasonic scaling and their impact on pro-inflammatory cytokine production by human gingival fibroblasts. METHODS Metal particles generated from ultrasonic scaling of titanium discs using two different tips (metal and poly-etheretherketone tips) were characterized using scanning electron microscopy and elemental analysis. Endotoxin levels and Human gingival fibroblast viability, in the presence commercial and ultrasonically generated particles were determined. Fibroblasts, cultured in high or low glucose growth medium, were incubated with commercial titanium particles or ultrasonically generated particles in the presence or absence of interluekin-1β. Interleukin 6 and interleukin 8 production were then quantified using Enzyme linked immunosorbent assay. RESULTS Analysis of particles after scaling of titanium discs showed significant levels of titanium particles. Commercial titanium particles and generated particles had no effect of fibroblast viability. Endotoxin levels of all particles were too low to stimulate HGF cells. IL-1β significantly stimulated IL-6 and IL-8 production. However, commercial, and generated particles generally had no significant effect on IL- 6 and IL-8 production. CONCLUSION Our study concluded that particles generated during ultrasonic scaling had no significant effect on viability of HGF cells and cytokine production.
Collapse
Affiliation(s)
- Pooja AjitSankardas
- Department of Periodontology, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN 38103
| | - Sidney H Stein
- Department of Periodontology, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN 38103
| | - David Tipton
- Department of Bioscience Research, University of Tennessee Health Science Center, College of Dentistry, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN 38103
| | - Vrushali Abhyankar
- Department of Periodontology, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN 38103
| | - Brian R Morrow
- Department of Bioscience Research, University of Tennessee Health Science Center, College of Dentistry, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN 38103
| |
Collapse
|
5
|
Tan NCP, Miller CM, Antunes E, Sharma D. Impact of physical decontamination methods on zirconia implant surface and subsequent bacterial adhesion: An in-vitro study. Clin Exp Dent Res 2021; 8:313-321. [PMID: 34599862 PMCID: PMC8874065 DOI: 10.1002/cre2.486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Revised: 08/17/2021] [Accepted: 08/23/2021] [Indexed: 11/15/2022] Open
Abstract
Objective To evaluate the effect of routinely used physical decontamination methods on the surface characteristics of zirconia implants and subsequent ability of bacteria to adhere in vitro. Background Physical decontamination methods commonly used in peri‐implantitis therapy and routine implant maintenance can potentially alter zirconia implant surfaces. Methods Acid‐etched zirconia discs were instrumented with titanium curette (TC), plastic curette, air abrasive device, ultrasonic scaler (US) with stainless steel tip. Following instrumentation, surface topography, and surface elemental composition was analyzed using 3D‐laser scanning microscopy and energy‐dispersive X‐ray spectroscopy, respectively. Subsequently, plaque biofilm was cultured on zirconia discs for 48 h and bacterial adhesion assessed using a turbidity test and scanning electron microscopy. Results A significant difference in surface roughness was observed between the US and control group (p < 0.05). The US and TC caused gray surface discolouration on zirconia discs due to deposition of metallic residue as confirmed by X‐ray spectroscopy. No significant difference in bacterial adhesion was noted among all treatment groups (p > 0.05). Conclusion TC and US with stainless steel tips should be used with caution due to deposition of metallic residue on the surface. Air abrasive devices and plastic curettes caused minimal surface alterations and are, therefore, safer for zirconia implant decontamination.
Collapse
Affiliation(s)
- Nathan Chiang Ping Tan
- College of Medicine and Dentistry, James Cook University, Smithfield, Queensland, Australia
| | - Catherine M Miller
- College of Public Health, Medical and Veterinary Sciences, James Cook University, Smithfield, Queensland, Australia.,Australian Institute of Tropical Health and Medicine, James Cook University, Smithfield, Queensland, Australia
| | - Elsa Antunes
- College of Science and Engineering, James Cook University, Townsville, Queensland, Australia
| | - Dileep Sharma
- College of Medicine and Dentistry, James Cook University, Smithfield, Queensland, Australia.,Australian Institute of Tropical Health and Medicine, James Cook University, Smithfield, Queensland, Australia
| |
Collapse
|
6
|
Secgin-Atar A, Aykol-Sahin G, Kocak-Oztug NA, Yalcin F, Gokbuget A, Baser U. Evaluation of Surface Change and Roughness in Implants Lost Due to Peri-Implantitis Using Erbium Laser and Various Methods: An In Vitro Study. NANOMATERIALS 2021; 11:nano11102602. [PMID: 34685043 PMCID: PMC8540706 DOI: 10.3390/nano11102602] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 09/23/2021] [Accepted: 09/28/2021] [Indexed: 12/31/2022]
Abstract
The aim of our study was to obtain similar surface properties and elemental composition to virgin implants after debridement of contaminated titanium implant surfaces covered with debris. Erbium-doped:yttrium, aluminum, and garnet (Er:YAG) laser, erbium, chromium-doped:yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) laser, curette, and ultrasonic device were applied to contaminated implant surfaces. Scanning electron microscopy (SEM) images were taken, the elemental profile of the surfaces was evaluated with energy dispersive X-ray spectroscopy (EDX), and the surface roughness was analyzed with profilometry. Twenty-eight failed implants and two virgin implants as control were included in the study. The groups were designed accordingly; titanium curette group, ultrasonic scaler with polyetheretherketone (PEEK) tip, Er: YAG very short pulse laser group (100 μs, 120 mJ/pulse 10 Hz), Er: YAG short-pulse laser group (300 μs, 120 mJ/pulse, 10 Hz), Er: YAG long-pulse laser group (600 μs, 120 mJ/pulse, 10 Hz), Er, Cr: YSGG1 laser group (1 W 10 Hz), Er, Cr: YSGG2 laser group (1.5 W, 30 Hz). In each group, four failed implants were debrided for 120 s. When SEM images and EDX findings and profilometry results were evaluated together, Er: YAG long pulse and ultrasonic groups were found to be the most effective for debridement. Furthermore, the two interventions have shown the closest topography of the sandblasted, large grit, acid-etched implant surface (SLA) as seen on virgin implants.
Collapse
Affiliation(s)
- Aslihan Secgin-Atar
- Periodontology Department, Faculty of Dentistry, Istanbul University, 34452 Istanbul, Turkey; (A.S.-A.); (N.A.K.-O.); (F.Y.)
| | - Gokce Aykol-Sahin
- Department of Periodontology, Faculty of Dentistry, Istanbul Okan University, 34959 Istanbul, Turkey;
| | - Necla Asli Kocak-Oztug
- Periodontology Department, Faculty of Dentistry, Istanbul University, 34452 Istanbul, Turkey; (A.S.-A.); (N.A.K.-O.); (F.Y.)
| | - Funda Yalcin
- Periodontology Department, Faculty of Dentistry, Istanbul University, 34452 Istanbul, Turkey; (A.S.-A.); (N.A.K.-O.); (F.Y.)
| | | | - Ulku Baser
- Periodontology Department, Faculty of Dentistry, Istanbul University, 34452 Istanbul, Turkey; (A.S.-A.); (N.A.K.-O.); (F.Y.)
- Correspondence: ; Tel.: +90-5053568644
| |
Collapse
|
7
|
Polizzi E, D'orto B, Tomasi S, Tetè G. A micromorphological/microbiological pilot study assessing three methods for the maintenance of the implant patient. Clin Exp Dent Res 2021; 7:156-162. [PMID: 33211411 PMCID: PMC8019768 DOI: 10.1002/cre2.345] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 10/03/2020] [Accepted: 10/10/2020] [Indexed: 12/19/2022] Open
Abstract
OBJECTIVE The aim of this study was to evaluate and compare the effectiveness of the ultrasonic piezoelectric inserts of EMS Steel Tip A, EMS Peek, and IS-TiP-STS-3E© in reducing peri-implant bacterial load without compromising the surface of implants during professional oral hygiene in the follow-up. MATERIALS AND METHODS Thirteen implants were examined (Winsix, Biosafin, Ancona, Italy). The implants were divided into five groups and analyzed with a SEM microscope and microbiological analysis to evaluate the possible modification of structure and the bacterial load reduction. RESULTS The control and A, B, and C test groups were initially contaminated in vitro with Streptococcus mutans. Subsequently, the A, B, and C test groups were treated by an only expert operator in standard conditions. Test groups A, B, and C were inoculated for 3 hr and, furthermore, microbiologically analyzed. CONCLUSION The gold standard of an implant maintenance is a significant reduction of the bacterial load without becoming aggressive. According to our results, despite the limitations of the study, the authors recommend the least aggressive IS-TiP-STS-3E© , but combined with an antimicrobial agent to reduce the bacterial load, because the IS-TiP-STS-3E© did not show appreciable results versus the EMS Peek in reducing the bacterial load.
Collapse
Affiliation(s)
- Elisabetta Polizzi
- Department of Dentistry, IRCCS San Raffaele HospitalVita Salute UniversityMilanItaly
| | - Bianca D'orto
- Department of Dentistry, IRCCS San Raffaele HospitalVita Salute UniversityMilanItaly
| | | | - Giulia Tetè
- Department of Dentistry, IRCCS San Raffaele HospitalVita Salute UniversityMilanItaly
| |
Collapse
|
8
|
Romanos GE, Fischer GA, Delgado-Ruiz R. Titanium Wear of Dental Implants from Placement, under Loading and Maintenance Protocols. Int J Mol Sci 2021; 22:1067. [PMID: 33494539 PMCID: PMC7865642 DOI: 10.3390/ijms22031067] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 01/05/2021] [Accepted: 01/19/2021] [Indexed: 12/13/2022] Open
Abstract
The objective of this review was to analyze the process of wear of implants leading to the shedding of titanium particles into the peri-implant hard and soft tissues. Titanium is considered highly biocompatible with low corrosion and toxicity, but recent studies indicate that this understanding may be misleading as the properties of the material change drastically when titanium nanoparticles (NPs) are shed from implant surfaces. These NPs are immunogenic and are associated with a macrophage-mediated inflammatory response by the host. The literature discussed in this review indicates that titanium NPs may be shed from implant surfaces at the time of implant placement, under loading conditions, and during implant maintenance procedures. We also discuss the significance of the micro-gap at the implant-abutment interface and the effect of size of the titanium particles on their toxicology. These findings are significant as the titanium particles can have adverse effects on local soft and hard tissues surrounding implants, implant health and prognosis, and even the health of systemic tissues and organs.
Collapse
Affiliation(s)
- Georgios E. Romanos
- Department of Periodontology, Laboratory for Periodontal-, Implant-, Phototherapy (LA-PIP), School of Dental Medicine, Stony Brook University, 106 Rockland Hall, Stony Brook, NY 11794-8700, USA;
- Department of Oral Surgery and Implant Dentistry, School of Dentistry, Johann Wolfgang Goethe University, 60590 Frankfurt, Germany
| | - Gerard A. Fischer
- Department of Periodontology, Laboratory for Periodontal-, Implant-, Phototherapy (LA-PIP), School of Dental Medicine, Stony Brook University, 106 Rockland Hall, Stony Brook, NY 11794-8700, USA;
| | - Rafael Delgado-Ruiz
- Department of Prosthodontics and Digital Technology, School of Dental Medicine, Stony Brook University, Stony Brook, NY 11794-8700, USA;
| |
Collapse
|
9
|
Tong Z, Fu R, Zhu W, Shi J, Yu M, Si M. Changes in the surface topography and element proportion of clinically failed SLA implants after in vitro debridement by different methods. Clin Oral Implants Res 2021; 32:263-273. [PMID: 33314381 DOI: 10.1111/clr.13697] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 12/01/2020] [Accepted: 12/03/2020] [Indexed: 12/22/2022]
Abstract
OBJECTIVE To evaluate the surface topography and element proportion changes in clinically failed implants after different modalities in vitro debridement and to compare the cleaning effect of different method combinations. MATERIAL AND METHODS Thirty clinical failed implants were treated by different debridement methods in vitro as follows: Group 1: physiologic saline irrigation; Group 2: glycine powder air polishing; Group 3: glycine powder air polishing + ethylenediaminetetraacetic acid (EDTA); Group 4: polyetheretherketone (PEEK) tip ultrasonic scaling; and Group 5: PEEK tip ultrasonic scaling + EDTA. The relative contaminated area reduction (RCAR), visual analogue scale (VAS, the higher value means, the better cleaning effect) and surface roughness were assessed using scanning electron microscopy (SEM), stereoscopic microscopy (SM) and white light interferometry (WLI). Surface chemistry was determined by energy dispersive spectroscopy (EDS). RESULTS Group 4 and Group 5 showed higher RCARs (82.90%, 82.89%), VAS scores (2.61, 2.33) and roughness reductions (-0.85 μm, -1.80 μm). Group 3 attained the highest decrease of C% (carbon, -26.67%), O% (oxygen, -13.71%) and N% (nitrogen, -5.66%), and the highest increase of Ti% (titanium, 49.67%). PEEK remnants were detected on the implant surface of Groups 4 and 5. CONCLUSION Within the limitation of the present in vitro design, PEEK tip ultrasonic scaling was more effective in eliminating visible contamination, while glycine powder air polishing combined with EDTA treatment was more conducive to expose the original surface element distribution. Both methods have their own advantages in decontamination, but none of them could reconstruct the surface as the pristine implant.
Collapse
Affiliation(s)
- Zian Tong
- Department of Oral Implantology, the Affiliated Stomatology Hospital, Zhejiang University School of Medicine, Zhejiang, China.,Key Laboratory of Oral Biomedical Research of Zhejiang Province, Zhejiang University School of Stomatology
| | - Renjie Fu
- Department of Oral Implantology, the Affiliated Stomatology Hospital, Zhejiang University School of Medicine, Zhejiang, China.,Department of Stomatology, the First People's Hospital of Tongxiang, Zhejiang, China
| | - Weijun Zhu
- Department of Oral Implantology, the Affiliated Stomatology Hospital, Zhejiang University School of Medicine, Zhejiang, China.,Key Laboratory of Oral Biomedical Research of Zhejiang Province, Zhejiang University School of Stomatology
| | - Jue Shi
- Key Laboratory of Oral Biomedical Research of Zhejiang Province, Zhejiang University School of Stomatology.,Department of Oral Maxillofacial Surgery, the Affiliated Stomatology Hospital, Zhejiang University School of Medicine, Zhejiang, China
| | - Mengfei Yu
- Department of Oral Implantology, the Affiliated Stomatology Hospital, Zhejiang University School of Medicine, Zhejiang, China.,Key Laboratory of Oral Biomedical Research of Zhejiang Province, Zhejiang University School of Stomatology
| | - Misi Si
- Department of Oral Implantology, the Affiliated Stomatology Hospital, Zhejiang University School of Medicine, Zhejiang, China.,Key Laboratory of Oral Biomedical Research of Zhejiang Province, Zhejiang University School of Stomatology
| |
Collapse
|
10
|
Sahrmann P, Winkler S, Gubler A, Attin T. Assessment of implant surface and instrument insert changes due to instrumentation with different tips for ultrasonic-driven debridement. BMC Oral Health 2021; 21:25. [PMID: 33413296 PMCID: PMC7791805 DOI: 10.1186/s12903-020-01384-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Accepted: 12/23/2020] [Indexed: 12/04/2022] Open
Abstract
Background To assess the changes of implant surfaces of different roughness after instrumentation with ultrasonic-driven scaler tips of different materials. Methods Experiments were performed on two moderately rough surfaces (I—Inicell® and II—SLA®), one surface without pre-treatment (III) and one smooth machined surface (IV). Scaler tips made of steel (A), PEEK (B), titanium (C), carbon (D) and resin (E) were used for instrumentation with a standardized pressure of 100 g for ten seconds and under continuous automatic motion. Each combination of scaler tip and implant surface was performed three times on 8 titanium discs. After instrumentation roughness was assessed by profilometry, morphological changes were assessed by scanning electron microscopy, and element distribution on the utmost surface by energy dispersive X-ray spectroscopy. Results The surface roughness of discs I and II were significantly reduced by instrumentation with all tips except E. For disc III and IV roughness was enhanced by tip A and C and, only for IV, by tip D. Instrumentation with tips B, D and E left extensive residuals on surface I, II and III. The element analysis of these deposits proved consistent with the elemental composition of the respective tip materials. Conclusion All ultrasonic instruments led to microscopic alterations of all types of implants surfaces assessed in the present study. The least change of implant surfaces might result from resin or carbon tips on machined surfaces.
Collapse
Affiliation(s)
- Philipp Sahrmann
- Clinic of Conservative and Preventive Dentistry, Periodontology and Cariology, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032, Zurich, Switzerland.
| | - Sophie Winkler
- Clinic of Conservative and Preventive Dentistry, Periodontology and Cariology, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032, Zurich, Switzerland
| | - Andrea Gubler
- Clinic of Conservative and Preventive Dentistry, Periodontology and Cariology, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032, Zurich, Switzerland
| | - Thomas Attin
- Clinic of Conservative and Preventive Dentistry, Periodontology and Cariology, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032, Zurich, Switzerland
| |
Collapse
|
11
|
Mensi M, Viviani L, Agosti R, Scotti E, Garzetti G, Calza S. Comparison between four different implant surface debridement methods: an in-vitro experimental study. ACTA ACUST UNITED AC 2020; 69:286-294. [PMID: 33174712 DOI: 10.23736/s0026-4970.20.04342-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
BACKGROUND Peri-implantitis treatment is a very challenging topic to discuss. What is certain is that preventive/supportive therapy plays a key-role in peri-implant tissues' health maintenance and non-surgical implant surface mechanical debridement remains one of the solid pillars in the therapeutic pathway. In this perspective, many surface decontaminating methods have been proposed and tested to remove hard and soft bacterial deposits. The aim of this study was to compare four different commonly used non-surgical implant debridement methods in terms of cleaning potential in vitro, using a peri-implant pocket-simulating model. METHODS Sixty-four dental implants were ink-stained and placed into a simulated peri-implant pocket. Samples were then divided into four groups and treated with different debridement methods: stainless-steel ultrasonic tip (PS), peek-coated ultrasonic tip (PI), sub-gingival air-polishing with erythritol powder (EHX) and sub-gingival air-polishing with glycine powder (GLY). For each treatment group, half of the samples were treated for 5 seconds and the other half for 45 seconds. High-resolution images were taken using a digital microscope and later analyzed with a light processing software for measuring the cleaned area percentage (ink-free). Two different images were captured for every sample: a first image with the implant positioned perpendicular to the microscope lenses (90°) and a second one with the implant placed with a 45° vertical angulation, with the smooth neck towards the ground. Percentage of removed ink was statistically modelled using a generalized linear mixed model with the implant as a random (clustering) factor. RESULTS A paired comparison between all treatments in terms of debridement potential (cleaned area percentage) was performed. In 5s and with 90° sample angulation EHX/PS comparison showed an odds ratio of 2.75 (P<0.001), PI/EHX an OR of 0.20 (P<0.001), GLY/PS an OR of 2.90 (P<0.001), PI/GLY an OR of 0.19 (P<0.001) and PI/PS an OR of 0.56 (P=0.105). With the same sample angulation and 45s treatment time, the OR was 6.97 (P<0.001) for EHX/PS comparison, 0.14 (P<0.001) for PI/EHX comparison, 4.99 (P<0.001) for GLY/PS, 0.19 (P<0.001) for PI/GLY and 0.95 for PI/PS (P =0.989). With 5s of treatment time and 45° sample angulation, EHX/PS comparison shows a 3.19 odds ratio (P<0.001), PI/EHX a 0.14 odds ratio (P<0.001), GLY/PS a 3.06 odds ratio (P<0.001), PI/GLY a 0.15 odds ratio (P<0.001) and PI/PS a 0.46 odds ratio (P=0.017). With the same sample angulation but 45s treatment time, EHX/PS comparison produced an odds ratio of 4.90 (P<0.001), PI/EHX an OR of 0.20 (P<0.001), GLY/PS an OR of 8.74 (P<0.001), PI/GLY an OR of 0.11 (P<0.001) and PI/PS an OR 0.96 of (P =0.996). CONCLUSIONS Among the four treatments considered, air-polishing therapy represents the best one in terms of ink removal from the implant surface. Furthermore, increasing the treatment time to 45 seconds, air-polishing resulted considerably more efficient.
Collapse
Affiliation(s)
- Magda Mensi
- Section of Periodontics, Department of Surgical Specialties, Radiological Sciences and Public Health, School of Dentistry, University of Brescia, Brescia, Italy
| | - Lorenzo Viviani
- Section of Periodontics, Department of Surgical Specialties, Radiological Sciences and Public Health, School of Dentistry, University of Brescia, Brescia, Italy -
| | - Raffaele Agosti
- Section of Periodontics, Department of Surgical Specialties, Radiological Sciences and Public Health, School of Dentistry, University of Brescia, Brescia, Italy
| | - Eleonora Scotti
- Section of Periodontics, Department of Surgical Specialties, Radiological Sciences and Public Health, School of Dentistry, University of Brescia, Brescia, Italy
| | - Gianluca Garzetti
- Section of Periodontics, Department of Surgical Specialties, Radiological Sciences and Public Health, School of Dentistry, University of Brescia, Brescia, Italy
| | - Stefano Calza
- Department of Molecular and Translational Medicine, University of Brescia, Brescia, Italy
| |
Collapse
|
12
|
Annual review of selected scientific literature: A report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2020; 124:274-349. [PMID: 32811666 DOI: 10.1016/j.prosdent.2020.06.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 06/23/2020] [Accepted: 06/24/2020] [Indexed: 01/20/2023]
Abstract
This comprehensive review of the 2019 restorative dental literature is offered to inform busy dentists regarding remarkable publications and noteworthy progress made in the profession. Developed by the Scientific Investigation Committee of the American Academy of Restorative Dentistry, each author brings discipline-specific expertise to 1 of 8 sections of the report: (1) prosthodontics; (2) periodontics, alveolar bone, and peri-implant tissues; (3) implant dentistry; (4) dental materials and therapeutics; (5) occlusion and temporomandibular disorders; (6) sleep-related breathing disorders; (7) oral medicine and oral and maxillofacial surgery; and (8) dental caries and cariology. The report targets important information likely to influence day-to-day dental treatment decisions. Each review is not intended to stand alone but to update interested readers so that they may visit source material when greater detail is desired. As the profession moves toward evidence-based clinical decision-making, an incredible volume of potentially valuable dental literature continues to increase. It is the intention of this review and its authors to provide assistance in negotiating the extensive dental literature published in 2019. It is our hope that readers find this work useful in the clinical management of dental patients.
Collapse
|
13
|
Abedini F, Hosseini HRM. Zeolite-based catalytic micromotors for enhanced biological and chemical water remediation. NEW J CHEM 2020. [DOI: 10.1039/d0nj04116e] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
The novel zeolite-based micromotors showed rapid and safe elimination of bacteria in a very short time and removed heavy metals efficiently.
Collapse
Affiliation(s)
- Fatemeh Abedini
- Department of Materials Science and Engineering
- Sharif University of Technology
- Tehran
- Iran
| | - H. R. Madaah Hosseini
- Department of Materials Science and Engineering
- Sharif University of Technology
- Tehran
- Iran
| |
Collapse
|