1
|
Hui SC, Murali-Manohar S, Zöllner HJ, Hupfeld KE, Davies-Jenkins CW, Gudmundson AT, Song Y, Yedavalli V, Wisnowski JL, Gagoski B, Oeltzschner G, Edden RA. Integrated Short-TE and Hadamard-edited Multi-Sequence (ISTHMUS) for Advanced MRS. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.02.15.580516. [PMID: 38659947 PMCID: PMC11042202 DOI: 10.1101/2024.02.15.580516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
Abstract
Background To examine data quality and reproducibility using ISTHMUS, which has been implemented as the standardized MR spectroscopy sequence for the multi-site Healthy Brain and Child Development (HBCD) study. Methods ISTHMUS is the consecutive acquisition of short-TE PRESS (32 transients) and long-TE HERCULES (224 transients) data with dual-TE water reference scans. Voxels were positioned in the centrum semiovale, dorsal anterior cingulate cortex, posterior cingulate cortex and bilateral thalamus regions. After acquisition, ISTHMUS data were separated into the PRESS and HERCULES portions for analysis and modeled separately using Osprey. In vivo experiments were performed in 10 healthy volunteers (6 female; 29.5±6.6 years). Each volunteer underwent two scans on the same day. Differences in metabolite measurements were examined. T2 correction based on the dual-TE water integrals were compared with: 1) T2 correction based the default white matter and gray matter T2 reference values in Osprey; 2) shorter WM and GM T2 values from recent literature; and 3) reduced CSF fractions. Results No significant difference in linewidth was observed between PRESS and HERCULES. Bilateral thalamus spectra had produced significantly higher (p<0.001) linewidth compared to the other three regions. Linewidth measurements were similar between scans, with scan-to-scan differences under 1 Hz for most subjects. Paired t-tests indicated a significant difference only in PRESS NAAG between the two thalamus scans (p=0.002). T2 correction based on shorter T2 values showed better agreement to the dual-TE water integral ratio. Conclusions ISTHMUS facilitated and standardized acquisition and post-processing and reduced operator workload to eliminate potential human error.
Collapse
Affiliation(s)
- Steve C.N. Hui
- Developing Brain Institute, Children’s National Hospital, Washington, D.C. USA
- Departments of Radiology, The George Washington University School of Medicine and Health Sciences, Washington, D.C. USA
- Departments of Pediatrics, The George Washington University School of Medicine and Health Sciences, Washington, D.C. USA
| | - Saipavitra Murali-Manohar
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Helge J. Zöllner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Kathleen E. Hupfeld
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Christopher W. Davies-Jenkins
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Aaron T. Gudmundson
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yulu Song
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Vivek Yedavalli
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Jessica L Wisnowski
- Department of Radiology, Children’s Hospital Los Angeles, Los Angeles, CA, USA
- Department of Pediatrics, Children’s Hospital Los Angeles, Los Angeles, CA, USA
| | - Borjan Gagoski
- Fetal Neonatal Neuroimaging and Developmental Science Center, Boston Children’s Hospital, Boston, MA, USA
- Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Georg Oeltzschner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Richard A.E. Edden
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| |
Collapse
|
2
|
Hui SC, Gong T, Zöllner HJ, Hupfeld KE, Gudmundson AT, Murali-Manohar S, Davies-Jenkins CW, Song Y, Chen Y, Oeltzschner G, Wang G, Edden RAE. sLASER and PRESS Perform Similarly at Revealing Metabolite-Age Correlations. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.01.18.524597. [PMID: 36711794 PMCID: PMC9882274 DOI: 10.1101/2023.01.18.524597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Purpose To compare the respective ability of PRESS and sLASER to reveal biological relationships, using age as a validation covariate. Methods MRS data were acquired from 102 healthy volunteers using PRESS and sLASER in centrum semiovale (CSO) and posterior cingulate cortex (PCC) regions. Acquisition parameters included TR/TE 2000/30 ms; 96 transients; 2048 datapoints sampled at 2 kHz.Spectra were analyzed using Osprey. Signal-to-noise ratio (SNR), full-width-half-maximum linewidth of tCr, and metabolite concentrations were extracted. A linear model was used to compare SNR and linewidth. Paired t-tests were used to assess differences in metabolite measurements between PRESS and sLASER. Correlations were used to evaluate the relationship between PRESS and sLASER metabolite estimates, as well as the strength of each metabolite-age relationship. Coefficients of variation were calculated to assess inter-subject variability in each metabolite measurement. Results SNR and linewidth were significantly higher (p<0.05) for sLASER than PRESS. Paired t-tests showed significant differences between PRESS and sLASER in most metabolite measurements. Metabolite measures were significantly correlated (p<0.05) for most metabolites between the two methods except GABA, Gln and Lac in CSO and GSH, Lac and NAAG in PCC. Metabolite-age relationships were consistently identified using both PRESS and sLASER. Similar CVs were observed for most metabolites. Conclusion The study results suggest strong agreement between PRESS and sLASER in identifying relationships between brain metabolites and age in CSO and PCC data acquired at 3T. sLASER is technically desirable due to the reduced chemical shift displacement artifact; however, PRESS performed similarly in 'good' brain regions at clinical field strength.
Collapse
Affiliation(s)
- Steve C.N. Hui
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Tao Gong
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Helge J. Zöllner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Kathleen E. Hupfeld
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Aaron T. Gudmundson
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Saipavitra Murali-Manohar
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Christopher W. Davies-Jenkins
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yulu Song
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yufan Chen
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Georg Oeltzschner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Guangbin Wang
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Richard A. E. Edden
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| |
Collapse
|
3
|
Riemann LT, Aigner CS, Ellison SLR, Brühl R, Mekle R, Schmitter S, Speck O, Rose G, Ittermann B, Fillmer A. Assessment of measurement precision in single-voxel spectroscopy at 7 T: Toward minimal detectable changes of metabolite concentrations in the human brain in vivo. Magn Reson Med 2021; 87:1119-1135. [PMID: 34783376 DOI: 10.1002/mrm.29034] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2021] [Revised: 09/14/2021] [Accepted: 09/16/2021] [Indexed: 12/13/2022]
Abstract
PURPOSE To introduce a study design and statistical analysis framework to assess the repeatability, reproducibility, and minimal detectable changes (MDCs) of metabolite concentrations determined by in vivo MRS. METHODS An unbalanced nested study design was chosen to acquire in vivo MRS data within different repeatability and reproducibility scenarios. A spin-echo, full-intensity acquired localized (SPECIAL) sequence was employed at 7 T utlizing three different inversion pulses: a hyperbolic secant (HS), a gradient offset independent adiabaticity (GOIA), and a wideband, uniform rate, smooth truncation (WURST) pulse. Metabolite concentrations, Cramér-Rao lower bounds (CRLBs) and coefficients of variation (CVs) were calculated. Both Bland-Altman analysis and a restricted maximum-likelihood estimation (REML) analysis were performed to estimate the different variance contributions of the repeatability and reproducibility of the measured concentration. A Bland-Altmann analysis of the spectral shape was performed to assess the variance of the spectral shape, independent of quantification model influences. RESULTS For the used setup, minimal detectable changes of brain metabolite concentrations were found to be between 0.40 µmol/g and 2.23 µmol/g. CRLBs account for only 16 % to 74 % of the total variance of the metabolite concentrations. The application of gradient-modulated inversion pulses in SPECIAL led to slightly improved repeatability, but overall reproducibility appeared to be limited by differences in positioning, calibration, and other day-to-day variations throughout different sessions. CONCLUSION A framework is introduced to estimate the precision of metabolite concentrations obtained by MRS in vivo, and the minimal detectable changes for 13 metabolite concentrations measured at 7 T using SPECIAL are obtained.
Collapse
Affiliation(s)
| | | | | | - Rüdiger Brühl
- Physikalisch-Technische Bundesanstalt, Braunschweig und Berlin, Germany
| | - Ralf Mekle
- Center for Stroke Research Berlin, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | | | - Oliver Speck
- Biomedical Magnetic Resonance, Otto-von-Guericke University, Magdeburg, Germany.,Research Campus STIMULATE, Magdeburg, Germany
| | - Georg Rose
- Research Campus STIMULATE, Magdeburg, Germany.,Institut für Medizintechnik, Otto-von-Guericke University, Magdeburg, Germany
| | - Bernd Ittermann
- Physikalisch-Technische Bundesanstalt, Braunschweig und Berlin, Germany
| | - Ariane Fillmer
- Physikalisch-Technische Bundesanstalt, Braunschweig und Berlin, Germany
| |
Collapse
|
4
|
Wong D, Schranz AL, Bartha R. Optimized in vivo brain glutamate measurement using long-echo-time semi-LASER at 7 T. NMR IN BIOMEDICINE 2018; 31:e4002. [PMID: 30144183 DOI: 10.1002/nbm.4002] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2017] [Revised: 07/03/2018] [Accepted: 07/06/2018] [Indexed: 06/08/2023]
Abstract
A short echo time (TE ) is commonly used for brain glutamate measurement by 1 H MRS to minimize drawbacks of long TE such as signal modulation due to J evolution and T2 relaxation. However, J coupling causes the spectral patterns of glutamate to change with TE , and the shortest achievable TE may not produce the optimal glutamate measurement. The purpose of this study was to determine the optimal TE for glutamate measurement at 7 T using semi-LASER (localization by adiabatic selective refocusing). Time-domain simulations were performed to model the TE dependence of glutamate signal energy, a measure of glutamate signal strength, and were verified against measurements made in the human sensorimotor cortex (five subjects, 2 × 2 × 2 cm3 voxel, 16 averages) on a 7 T MRI scanner. Simulations showed a local maximum of glutamate signal energy at TE = 107 ms. In vivo, TE = 105 ms produced a low Cramér-Rao lower bound of 6.5 ± 2.0% across subjects, indicating high-quality fits of the prior knowledge model to in vivo data. TE = 105 ms also produced the greatest glutamate signal energy with the smallest inter-subject glutamate-to-creatine ratio (Glu/Cr) coefficient of variation (CV), 4.6%. Using these CVs, we performed sample size calculations to estimate the number of participants per group required to detect a 10% change in Glu/Cr between two groups with 95% confidence. 13 were required at TE = 45 ms, the shortest achievable echo time on our 7 T MRI scanner, while only 5 were required at TE = 105 ms, indicating greater statistical power. These results indicate that TE = 105 ms is optimum for in vivo glutamate measurement at 7 T with semi-LASER. Using long TE decreases power deposition by allowing lower maximum RF pulse amplitudes in conjunction with longer RF pulses. Importantly, long TE minimizes macromolecule contributions, eliminating the requirement for acquisition of separate macromolecule spectra or macromolecule fitting techniques, which add additional scan time or bias the estimated glutamate fit.
Collapse
Affiliation(s)
- Dickson Wong
- Department of Medical Biophysics, The University of Western Ontario, London, ON, Canada
- Centre for Functional and Metabolic Mapping, Robarts Research Institute, The University of Western Ontario, London, ON, Canada
| | - Amy L Schranz
- Department of Medical Biophysics, The University of Western Ontario, London, ON, Canada
- Centre for Functional and Metabolic Mapping, Robarts Research Institute, The University of Western Ontario, London, ON, Canada
| | - Robert Bartha
- Department of Medical Biophysics, The University of Western Ontario, London, ON, Canada
- Centre for Functional and Metabolic Mapping, Robarts Research Institute, The University of Western Ontario, London, ON, Canada
| |
Collapse
|
5
|
Volovyk O, Tal A. Application of phase rotation to STRESS localization scheme at 3 T. Magn Reson Med 2017; 79:2481-2490. [PMID: 28972290 DOI: 10.1002/mrm.26911] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Revised: 08/10/2017] [Accepted: 08/17/2017] [Indexed: 12/26/2022]
Abstract
PURPOSE Application of phase rotation to the STRESS (=STEAM+PRESS) localization scheme, to shorten echo time, minimize J-coupling dephasing and estimate B1+ inhomogeneity. STRESS (=STEAM + PRESS) simultaneously refocuses and acquires the double spin echo (SE123 ) and stimulated echo (STE- ) pathways, combining PRESS-like signal with lower chemical shift displacement as in STEAM. Phase rotation effectively separates coherence pathways, allows reduction of spoiling gradients moments leading to reduction in echo time. Implementing it in STRESS allows one to individually phase-correct SE123 and STE- prior to combination. Moreover, B1+ inhomogeneity can be assessed by comparing the measured ratio of resonance intensities of SE123 and STE- pathways to the simulated one. METHODS In vivo spectra were acquired from a single voxel placed in the sensory-motor cortex of 10 healthy volunteers, using phase rotation-STRESS/PRESS/STEAM sequences at 3 T scanner. The phases of each slice-selective pulse were incremented by Δϕ1/2/3=22.5°/-45°/45°. RESULTS Phase rotation-STRESS showed quantification accuracy (% Cramer Rao lower bounds) and reproducibility (% coefficients of variation) comparable to PRESS and STEAM, in both phantoms and in vivo study. Minimal echo time achieved was 13 ms. CONCLUSION Phase rotation complements STRESS by reducing echo time, allowing processing of each pathway individually prior to addition and providing B1+ estimation in single voxel proton magnetic resonance spectroscopy. Magn Reson Med 79:2481-2490, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Osnat Volovyk
- Chemical Physics Department, Weizmann Institute of Science, Rehovot, Israel
| | - Assaf Tal
- Chemical Physics Department, Weizmann Institute of Science, Rehovot, Israel
| |
Collapse
|
6
|
Gottschalk M, Troprès I, Lamalle L, Grand S, Le Bas JF, Segebarth C. Refined modelling of the short-T2 signal component and ensuing detection of glutamate and glutamine in short-TE, localised, (1) H MR spectra of human glioma measured at 3 T. NMR IN BIOMEDICINE 2016; 29:943-951. [PMID: 27197077 DOI: 10.1002/nbm.3548] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Revised: 03/22/2016] [Accepted: 04/07/2016] [Indexed: 06/05/2023]
Abstract
Short-TE (1) H MRS has great potential for brain cancer diagnostics. A major difficulty in the analysis of the spectra is the contribution from short-T2 signal components, mainly coming from mobile lipids. This complicates the accurate estimation of the spectral parameters of the resonance lines from metabolites, so that a qualitative to semi-quantitative interpretation of the spectra dominates in practice. One solution to overcome this difficulty is to measure and estimate the short-T2 signal component and to subtract it from the total signal, thus leaving only the metabolite signals. The technique works well when applied to spectra obtained from healthy individuals, but requires some optimisation during data acquisition. In the clinical setting, time constraints hardly allow this. Here, we propose an iterative estimation of the short-T2 signal component, acquired in a single acquisition after measurement of the full spectrum. The method is based on QUEST (quantitation based on quantum estimation) and allows the refinement of the estimate of the short-T2 signal component after measurement. Thus, acquisition protocols used on healthy volunteers can also be used on patients without further optimisation. The aim is to improve metabolite detection and, ultimately, to enable the estimation of the glutamine and glutamate signals distinctly. These two metabolites are of great interest in the characterisation of brain cancer, gliomas in particular. When applied to spectra from healthy volunteers, the new algorithm yields similar results to QUEST and direct subtraction of the short-T2 signal component. With patients, up to 12 metabolites and, at least, seven can be quantified in each individual brain tumour spectrum, depending on the metabolic state of the tumour. The refinement of the short-T2 signal component significantly improves the fitting procedure and produces a separate short-T2 signal component that can be used for the analysis of mobile lipid resonances. Thus, in brain tumour spectra, distinct estimates of signals from glutamate and glutamine are possible. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
| | - Irène Troprès
- Univ. Grenoble Alpes, IRMaGe, CNRS, UMR 3552, INSERM, US17 and CLUNI, CHU de Grenoble, IRMaGe, F-38000, Grenoble, France
| | - Laurent Lamalle
- Univ. Grenoble Alpes, IRMaGe, CNRS, UMR 3552, INSERM, US17 and CLUNI, CHU de Grenoble, IRMaGe, F-38000, Grenoble, France
| | - Sylvie Grand
- Université des Alpes Grenoble 1, Grenoble Institut des Neurosciences, Equipe 5, Clinique Universitaire de Neuroradiologie et IRM (CLUNI) and Centre Hospitalier Universitaire de Grenoble et des Alpes (CHUGA), Grenoble, France
| | - Jean-François Le Bas
- Université des Alpes Grenoble 1, Grenoble Institut des Neurosciences, Equipe 5, Clinique Universitaire de Neuroradiologie et IRM (CLUNI) and Centre Hospitalier Universitaire de Grenoble et des Alpes (CHUGA), Grenoble, France
| | | |
Collapse
|
7
|
Rowland LM, Kontson K, West J, Edden RA, Zhu H, Wijtenburg SA, Holcomb HH, Barker PB. In vivo measurements of glutamate, GABA, and NAAG in schizophrenia. Schizophr Bull 2013; 39:1096-104. [PMID: 23081992 PMCID: PMC3756774 DOI: 10.1093/schbul/sbs092] [Citation(s) in RCA: 116] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
The major excitatory and inhibitory neurotransmitters, glutamate (Glu) and gamma-aminobutyric acid (GABA), respectively, are implicated in the pathophysiology of schizophrenia. N-acetyl-aspartyl-glutamate (NAAG), a neuropeptide that modulates the Glu system, may also be altered in schizophrenia. This study investigated GABA, Glu + glutamine (Glx), and NAAG levels in younger and older subjects with schizophrenia. Forty-one subjects, 21 with chronic schizophrenia and 20 healthy controls, participated in this study. Proton magnetic resonance spectroscopy ((1)H-MRS) was used to measure GABA, Glx, and NAAG levels in the anterior cingulate (AC) and centrum semiovale (CSO) regions. NAAG in the CSO was higher in younger schizophrenia subjects compared with younger control subjects. The opposite pattern was observed in the older groups. Glx was reduced in the schizophrenia group irrespective of age group and brain region. There was a trend for reduced AC GABA in older schizophrenia subjects compared with older control subjects. Poor attention performance was correlated to lower AC GABA levels in both groups. Higher levels of CSO NAAG were associated with greater negative symptom severity in schizophrenia. These results provide support for altered glutamatergic and GABAergic function associated with illness course and cognitive and negative symptoms in schizophrenia. The study also highlights the importance of studies that combine MRS measurements of NAAG, GABA, and Glu for a more comprehensive neurochemical characterization of schizophrenia.
Collapse
Affiliation(s)
- Laura M. Rowland
- Maryland Psychiatric Research Center, Department of Psychiatry, University of Maryland School of Medicine, Baltimore MD;,To whom correspondence should be addressed; P O Box 21247, Baltimore, MD 21228, USA; tel: 410-402-6803; fax: 410-402-6077; e-mail:
| | - Kimberly Kontson
- Maryland Psychiatric Research Center, Department of Psychiatry, University of Maryland School of Medicine, Baltimore MD
| | - Jeffrey West
- Maryland Psychiatric Research Center, Department of Psychiatry, University of Maryland School of Medicine, Baltimore MD
| | - Richard A. Edden
- Russell H Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore MD;,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore MD
| | - He Zhu
- Russell H Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore MD;,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore MD
| | - S. Andrea Wijtenburg
- Maryland Psychiatric Research Center, Department of Psychiatry, University of Maryland School of Medicine, Baltimore MD
| | - Henry H. Holcomb
- Maryland Psychiatric Research Center, Department of Psychiatry, University of Maryland School of Medicine, Baltimore MD
| | - Peter B. Barker
- Russell H Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore MD;,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore MD
| |
Collapse
|
8
|
Reconstructing very short TE phase rotation spectral data collected with multichannel phased-array coils at 3 T. Magn Reson Imaging 2011; 29:937-42. [PMID: 21550744 DOI: 10.1016/j.mri.2011.03.005] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2010] [Revised: 03/15/2011] [Accepted: 03/19/2011] [Indexed: 11/22/2022]
Abstract
Phased-array volume coils were used in conjunction with the phase rotation STEAM (PR-STEAM) spectroscopy technique to acquire very short TE data from the anterior cingulate gyrus at 3 T. A method for combining PR-STEAM data from multiple subcoils is presented. The data were acquired from seven healthy participants using PR-STEAM (repetition time/mixing time/echo time=3500/10/6.5 ms, 6 cm(3), NEX=128, spectral width=2000 Hz, 2048 complex points, Δφ(1)=135°, Δφ(2)=22.5°, Δφ(3)=112.5° and Δφ(ADC)=0°). In addition to the primary metabolites, LCModel fit results suggest that glutathione and glutamate can also be identified with Cramér-Rao lower bounds of 10% or less.
Collapse
|
9
|
Cheung JS, Fan SJ, Gao DS, Chow AM, Yang J, Man K, Wu EX. In vivo lipid profiling using proton magnetic resonance spectroscopy in an experimental liver fibrosis model. Acad Radiol 2011; 18:377-83. [PMID: 21167757 DOI: 10.1016/j.acra.2010.10.012] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2010] [Revised: 10/27/2010] [Accepted: 10/29/2010] [Indexed: 12/19/2022]
Abstract
RATIONALE AND OBJECTIVES The aim of this study was to characterize early hepatic lipid changes in an experimental model of liver fibrosis using proton ((1)H) magnetic resonance spectroscopy (MRS) at high magnetic field in vivo. MATERIALS AND METHODS Liver fibrosis was induced in 12 Sprague-Dawley rats by twice-weekly carbon tetrachloride (CCl(4)) administration up to 4 weeks. Eight normal rats were used as controls. Single-voxel (1)H MRS experiments were performed at 7 Tesla to measure signal integrals of various lipid peaks including -CH(3), (-CH(2)-)(n), -CH(2)-C=C-CH(2)-, =C-CH(2)-C= and -CH=CH- at 0.9, 1.3, 2.0, 2.8, and 5.3 ppm, respectively, and peak from choline-containing compounds (CCC) at 3.2 ppm. Total lipid, total saturated fatty acid, total unsaturated fatty acid, total unsaturated bond, polyunsaturated bond, and CCC indices were quantified. RESULTS Significant increases (P < .01) in total lipid and total saturated fatty acid indices were found in animals with CCl(4)-induced fibrosis as compared with normal animals. In addition, total unsaturated bond and polyunsaturated bond indices of animals at 4 weeks after CCl(4) insult were significantly higher than (P < .01 and P < .05, respectively) those of normal animals and animals at 2 weeks following insult; whereas there was only significant increase (P < .01) in total unsaturated fatty acid index in animals with 4-week CCl(4) insult as compared with normal animals. CONCLUSION The hepatic lipid changes in CCl(4)-induced experimental fibrosis model were documented in vivo and longitudinally using (1)H MRS at 7 Tesla. The experimental findings suggested that total saturated fatty acid increase contributed mainly to the total lipid increase in animals with CCl(4) insult. This study also demonstrated the potential value of high field MRS to resolve lipid composition and alterations in liver fibrosis.
Collapse
|
10
|
Oz G, Tkáč I. Short-echo, single-shot, full-intensity proton magnetic resonance spectroscopy for neurochemical profiling at 4 T: validation in the cerebellum and brainstem. Magn Reson Med 2010; 65:901-10. [PMID: 21413056 DOI: 10.1002/mrm.22708] [Citation(s) in RCA: 132] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2010] [Revised: 10/04/2010] [Accepted: 10/08/2010] [Indexed: 11/08/2022]
Abstract
A short echo time (TE = 24 ms) semiadiabatic localization by adiabatic selective refocusing (LASER) sequence was designed and optimized for full-intensity proton magnetic resonance spectroscopy ((1) H MRS) at 4 T. The sequence was combined with VAPOR water suppression and three-dimensional outer volume suppression for improved localization and suppression of unwanted coherences. Artifact-free, single-shot spectra were obtained from the human brain with a spectral pattern almost identical to that obtained with an ultra-short TE (TE = 5 ms) stimulated-echo acquisition mode (STEAM) sequence as a result of the train of adiabatic refocusing pulses in semi-LASER that reduce the apparent TE. Approximately 2-fold higher signal intensity relative to STEAM was demonstrated in phantoms and the human brain. To test the performance of the sequence in clinically relevant brain regions with a volume coil, semi-LASER spectra were acquired from three cerebellar and brainstem volumes of interest (VOIs) in 23 healthy subjects. Ultra-short echo STEAM spectra were acquired from the same VOIs to compare neurochemical profiles obtained with semi-LASER with those obtained with STEAM. Neurochemical profiles of the cerebellum and brainstem acquired by these two techniques were nearly identical, validating the accuracy of the metabolite concentrations obtained with semi-LASER at the longer TE relative to STEAM. A high correlation between metabolite concentrations obtained by these two proton (1) H MRS techniques indicated the sensitivity to detect intersubject variation in metabolite levels.
Collapse
Affiliation(s)
- Gülin Oz
- Center for MR Research, Department of Radiology, Medical School, University of Minnesota, Minneapolis, Minnesota 55455, USA.
| | | |
Collapse
|
11
|
Andronesi OC, Ramadan S, Ratai EM, Jennings D, Mountford CE, Sorensen AG. Spectroscopic imaging with improved gradient modulated constant adiabaticity pulses on high-field clinical scanners. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2010; 203:283-93. [PMID: 20163975 PMCID: PMC3214007 DOI: 10.1016/j.jmr.2010.01.010] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2009] [Revised: 01/16/2010] [Accepted: 01/19/2010] [Indexed: 05/06/2023]
Abstract
The purpose of this work was to design and implement constant adiabaticity gradient modulated pulses that have improved slice profiles and reduced artifacts for spectroscopic imaging on 3T clinical scanners equipped with standard hardware. The newly proposed pulses were designed using the gradient offset independent adiabaticity (GOIA, Tannus and Garwood[13]) method using WURST modulation for RF and gradient waveforms. The GOIA-WURST pulses were compared with GOIA-HSn (GOIA based on nth-order hyperbolic secant) and FOCI (frequency offset corrected inversion) pulses of the same bandwidth and duration. Numerical simulations and experimental measurements in phantoms and healthy volunteers are presented. GOIA-WURST pulses provide improved slice profile that have less slice smearing for off-resonance frequencies compared to GOIA-HSn pulses. The peak RF amplitude of GOIA-WURST is much lower (40% less) than FOCI but slightly higher (14.9% more) to GOIA-HSn. The quality of spectra as shown by the analysis of lineshapes, eddy currents artifacts, subcutaneous lipid contamination and SNR is improved for GOIA-WURST. GOIA-WURST pulse tested in this work shows that reliable spectroscopic imaging could be obtained in routine clinical setup and might facilitate the use of clinical spectroscopy.
Collapse
Affiliation(s)
- Ovidiu C. Andronesi
- Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02114
- Address correspondence/reprints request to: Ovidiu C. Andronesi or A. Gregory Sorensen, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, 149 Thirteenth Street, Suite 2301, Boston, MA 02129, USA; ; , Tel: 617-643-6864; Fax: 617 726-7422
| | - Saadallah Ramadan
- Center for Clinical Spectroscopy, Department of Radiology, Brigham & Women’s Hospital, Harvard Medical School, Boston, MA 02115
| | - Eva-Maria Ratai
- Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02114
| | - Dominique Jennings
- Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02114
| | - Carolyn E. Mountford
- Center for Clinical Spectroscopy, Department of Radiology, Brigham & Women’s Hospital, Harvard Medical School, Boston, MA 02115
| | - A. Gregory Sorensen
- Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02114
- Address correspondence/reprints request to: Ovidiu C. Andronesi or A. Gregory Sorensen, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, 149 Thirteenth Street, Suite 2301, Boston, MA 02129, USA; ; , Tel: 617-643-6864; Fax: 617 726-7422
| |
Collapse
|
12
|
Abstract
PURPOSE To identify the pulse sequence and acquisition parameters that result in the most accurate and repeatable measurements of glutamate (Glu) concentration in the brain at 3T. MATERIALS AND METHODS Simulations were performed to compare the accuracy and repeatability of 11 pulse sequences and acquisition parameters, within four general classes (PRESS, STEAM, Carr-Purcell PRESS [CPRESS] and TE averaged PRESS [JPRESS]), the majority of which were previously suggested as optimal for Glu detection. Three of the simulated acquisitions were implemented in a clinical scanner and measures of repeatability in vivo were compared to their simulated values. RESULTS Good agreement was demonstrated between simulated and experimentally determined measures of repeatability. Among the acquisitions considered, a CPRESS sequence with minimal echo time, together with, possibly, a short TE PRESS sequence, result in the most repeatable within session Glu measurements, while slightly overestimating the Glu concentration. Excellent accuracy is demonstrated by the simulations for a JPRESS sequence, at the expense of lower repeatability than optimal PRESS or CPRESS sequences. CONCLUSION Further proof of concept is presented toward validation of a simulation approach to understand pulse sequence performance in measuring the concentration of a given metabolite. Improved within session Glu measurement repeatability is predicted for CPRESS and demonstrated in vivo.
Collapse
Affiliation(s)
- Ileana Hancu
- GE Global Research Center, Niskayuna, New York 12309, USA.
| |
Collapse
|
13
|
Choi C, Zhao C, Dimitrov I, Douglas D, Coupland NJ, Kalra S, Hawesa H, Davis J. Measurement of glutathione in human brain at 3T using an improved double quantum filter in vivo. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2009; 198:160-166. [PMID: 19261496 PMCID: PMC2921904 DOI: 10.1016/j.jmr.2009.02.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2008] [Revised: 02/05/2009] [Accepted: 02/05/2009] [Indexed: 05/27/2023]
Abstract
A single voxel proton NMR double quantum filter (DQF) for measurement of glutathione (GSH) in human brain at 3T is reported. Yield enhancement for the CH(2) resonances of the cysteine moiety at 2.95ppm has been achieved by means of dual encoding. After the preparation of double quantum and zero quantum coherences (DQC and ZQC) at equal magnitude, the first DQC encoding was followed by interchange of DQC and ZQC, and another DQC encoding. The multi-quantum coherences were fully utilized to generate a GSH target signal at approximately 2.95ppm. The optimal echo time and the editing efficiency were obtained with numerical analysis of the filtering performance and phantom measurements. The dual-DQC encoding method provided GSH yield greater by a factor of 2.1 than single-DQC encoding for identical slice-selective RF pulses in phantom tests. Using the phantom relaxation times and the ratio of edited GSH to N-acetylaspartate (NAA) 2.0-ppm peak areas, the concentration of GSH in the medial parietal cortex of the healthy human brain in vivo was estimated to be 1.0+/-0.3mM (mean+/-SD, n=7), with reference to NAA at 10mM.
Collapse
Affiliation(s)
- Changho Choi
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd., Dallas, TX 75390, USA.
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Mekle R, Mlynárik V, Gambarota G, Hergt M, Krueger G, Gruetter R. MR spectroscopy of the human brain with enhanced signal intensity at ultrashort echo times on a clinical platform at 3T and 7T. Magn Reson Med 2009; 61:1279-85. [DOI: 10.1002/mrm.21961] [Citation(s) in RCA: 254] [Impact Index Per Article: 16.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
15
|
Abstract
Optimized myo-inositol (mI) detection is important for diagnosing and monitoring a multitude of pathological conditions of the brain. Simulations are presented in this work, performed to decide which pulse sequence has the most significant advantage in terms of improving repeatability and accuracy of mI measurements at 3T over the pulse sequence used typically in the clinic, a TE = 35 ms PRESS sequence. Five classes of pulse sequences, four previously suggested for optimized mI detection (a short TE PRESS, a Carr-Purcell PRESS sequence, an optimized STEAM sequence, an optimized zero quantum filter), and one optimized for mI detection in this work (a single quantum filter) were compared to a standard, TE = 35 ms pulse sequence. While limiting the SNR of an acquisition to the equivalent SNR of a spectrum acquired in 5 min from an 8 cc voxel, it was found through simulations that the most repeatable mI measurements would be obtained with a Carr-Purcell sequence. This sequence was implemented in a clinical scanner, and improved mI measurements were demonstrated in vivo.
Collapse
Affiliation(s)
- Ileana Hancu
- GE Global Research Center, Niskayuna, New York 12309, USA.
| |
Collapse
|
16
|
Gimenez M, Soria-Pastor S, Junque C, Caldu X, Narberhaus A, Botet F, Bargallo N, Falcon C, Mercader JM. Proton magnetic resonance spectroscopy reveals medial temporal metabolic abnormalities in adolescents with history of preterm birth. Pediatr Res 2008; 64:572-7. [PMID: 18596571 DOI: 10.1203/pdr.0b013e3181841eab] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Prematurity is associated with volumetric reductions in specific brain areas such as the hippocampus and with metabolic changes that can be detected by spectroscopy. Short echo time (35 ms) Proton magnetic resonance spectroscopy (1H MRS) was performed to assess possible medial temporal lobe metabolic abnormalities in 21 adolescents with preterm birth (mean age: 14.8, SD: 1.3) compared with an age-matched control sample (mean age: 14.8, SD: 1.6). 1H MRS spectra were analyzed with linear combination model fitting, obtaining the absolute metabolite concentrations for Creatine (Cr), and myo-inositol (Ins). In addition, the following metabolite sums were measured: total Cho (glycerophospho-choline + phosphocholine), total N-acetyl-aspartate + N-acetyl-aspartylglutamate (NA), and total Glx (glutamate + glutamine). A stereological analysis was performed to calculate hippocampal volume. Absolute Cr, and total NA values were decreased in the preterm group (p = 0.016; p = 0.002, respectively). The preterm also showed a hippocampal reduction (p < 0.0001). Significant relationships were found between gestational age and different metabolites and the hippocampal volume. Moreover, hippocampal volume correlated with brain metabolites in the whole sample. Results demonstrate that prematurity affects medial temporal lobe metabolites, and that the alteration is related to structural changes, suggesting that the cerebral changes persist until adolescence.
Collapse
Affiliation(s)
- Monica Gimenez
- Department of Psychiatry and Clinical Psychobiology, University of Barcelona, Barcelona 08036, Spain
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Gottschalk M, Lamalle L, Segebarth C. Short-TE localised 1H MRS of the human brain at 3 T: quantification of the metabolite signals using two approaches to account for macromolecular signal contributions. NMR IN BIOMEDICINE 2008; 21:507-517. [PMID: 17955570 DOI: 10.1002/nbm.1219] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The goal of this study was to validate metabolite quantification at short TE, with particular focus on how to best account for the macromolecular signal contribution. A robust, short-TE PRESS protocol is presented, which allows reliable quantification, in vivo, of metabolite signals at 3 T in human brain. Water suppression was adapted to the experimental conditions at 3 T. Metabolite signal from the parietal white matter was quantified in the time domain using QUEST (jMRUI). The increased macromolecular signal contribution at short TE was dealt with by two approaches, based on either metabolite nulling or initial signal truncation. A detailed comparison of the two approaches was made. The first used a metabolite-nulled signal, measured either individually or averaged over different subjects. The second used the total signal, metabolites and macromolecules, from a single scan. The two approaches gave similar quantification results in terms of metabolite concentrations, but differed in their precision and the number of metabolites quantified reliably. With an average metabolite-nulled baseline, a set of seven metabolites could be reliably quantified in parietal white matter under these experimental conditions: N-acetylaspartate, myo-inositol, glucose, glutamate, glutathione, creatine and choline. When initial signal truncation was used, glucose was removed from this set. The short TE (10-11 ms) facilitated quantification of glutamate. The reliable quantification of N-acetylaspartyl glutamate at 3 T proved very difficult.
Collapse
|
18
|
Yahya A, Mädler B, Fallone BG. Exploiting the chemical shift displacement effect in the detection of glutamate and glutamine (Glx) with PRESS. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2008; 191:120-127. [PMID: 18249017 DOI: 10.1016/j.jmr.2007.12.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2007] [Revised: 12/19/2007] [Accepted: 12/19/2007] [Indexed: 05/25/2023]
Abstract
A PRESS (Point RESolved Spectroscopy) sequence for the improved detection of the C2 protons of Glx (glutamate and glutamine) at approximately 3.75ppm is presented in this work. It is shown that for spins like the C2 protons of Glx which are involved solely in weak coupling interactions, the chemical shift displacement effect can be turned to advantage by exploiting PRESS refocusing pulses with bandwidths less than the chemical shift difference between the target spins and the spins to which they are weakly coupled. The narrow-bandwidth PRESS sequence allows refocusing of the J-coupling evolution of the target protons in the voxel of interest independently of echo time yielding signal equivalent to that which can be obtained with a one-pulse acquire sequence (assuming ideal pulses and ignoring T2 relaxation). The total echo time of PRESS was set long enough for the decay of macromolecule signal and the two echo times were empirically optimized so that the Glx signal at 3.75ppm suffered minimal contamination from myo-inositol. The efficacy of the method was verified on phantom solutions of Glx and on brain in vivo.
Collapse
Affiliation(s)
- Atiyah Yahya
- Department of Medical Physics, Cross Cancer Institute, 11560 University Avenue, Edmonton, Alta., Canada T6G 1Z2.
| | | | | |
Collapse
|
19
|
Abstract
The noninvasive localization of the epileptogenic zone continues to be a challenge in many patients that present as candidates for possible epilepsy surgery. Magnetic resonance imaging (MRI) techniques provide accurate anatomical definition, but despite their high resolution, these techniques fail to visualize the pathological neocortical and hippocampal changes in a sizable number of patients with focal pathologies. Further, visualized lesions on MRI may not all produce seizures. One of the keys to the understanding of the epileptogenic zone lies in the recognition of the metabolic alterations that occur in the setting of epileptic seizures. Magnetic resonance spectroscopy (MRS) is a valuable tool that can be used to study the metabolic changes seen in both acute and chronic animal models of epilepsy. Such study allows for the identification of epileptic tissue with high sensitivity and specificity. We present here a review of the use of MRS in animal models of epilepsy.
Collapse
Affiliation(s)
- Girish K Hiremath
- Department of Neurosurgery, Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland, Ohio 44195, USA
| | | |
Collapse
|
20
|
Mlynárik V, Gambarota G, Frenkel H, Gruetter R. Localized short-echo-time proton MR spectroscopy with full signal-intensity acquisition. Magn Reson Med 2006; 56:965-70. [PMID: 16991116 DOI: 10.1002/mrm.21043] [Citation(s) in RCA: 218] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
We developed a short-echo-time (TE) sequence for proton localized spectroscopy by combining a 1D add-subtract scheme with a doubly slice-selective spin-echo (SE) sequence. The sequence preserves the full magnetization available from the selected volume of interest (VOI). By reducing the number of radiofrequency (RF) pulses acting on transverse magnetization, we were able to minimize the TE to the level that is achievable with the stimulated echo acquisition mode (STEAM) technique, and also gained a twofold increase in sensitivity. The use of an adiabatic pulse in the add-subtract localization improved the efficiency of excitation in spatially inhomogeneous RF fields, which are frequently encountered at high magnetic fields. The localization performance and sensitivity gains of this method, which is termed SPin ECho, full Intensity Acquired Localized (SPECIAL) spectroscopy, were demonstrated in vivo in rat brains. In conjunction with spectroscopic imaging, a 2-microl spatial resolution was accomplished with a signal-to-noise ratio (SNR) above 30, which is usually sufficient for reliable quantification of a large number of metabolites (neurochemical profile).
Collapse
Affiliation(s)
- Vladimír Mlynárik
- Laboratory of Functional and Metabolic Imaging, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | | | | | | |
Collapse
|
21
|
Abstract
The ability to select a discrete region within the body for signal acquisition is a fundamental requirement of in vivo NMR spectroscopy. Ideally, it should be possible to tailor the selected volume to coincide exactly with the lesion or tissue of interest, without loss of signal from within this volume or contamination with extraneous signals. Many techniques have been developed over the past 25 years employing a combination of RF coil properties, static magnetic field gradients and pulse sequence design in an attempt to meet these goals. This review presents a comprehensive survey of these techniques, their various advantages and disadvantages, and implications for clinical applications. Particular emphasis is placed on the reliability of the techniques in terms of signal loss, contamination and the effect of nuclear relaxation and J-coupling. The survey includes techniques based on RF coil and pulse design alone, those using static magnetic field gradients, and magnetic resonance spectroscopic imaging. Although there is an emphasis on techniques currently in widespread use (PRESS, STEAM, ISIS and MRSI), the review also includes earlier techniques, in order to provide historical context, and techniques that are promising for future use in clinical and biomedical applications.
Collapse
Affiliation(s)
- Stephen F Keevil
- Department of Medical Physics, Guy's and St Thomas' NHS Foundation Trust, Guy's Hospital, London, SE1 9RT, UK.
| |
Collapse
|
22
|
Pan JW, Venkatraman T, Vives K, Spencer DD. Quantitative glutamate spectroscopic imaging of the human hippocampus. NMR IN BIOMEDICINE 2006; 19:209-16. [PMID: 16479532 PMCID: PMC3657732 DOI: 10.1002/nbm.1019] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
We have evaluated a three-dimensional localized spectroscopic imaging sequence that uses two pairs of adiabatic full-passage pulses, which optimizes the detection of glutamate resonances at moderate echo times. This sequence provides excellent volume localization while simultaneously reducing J-modulation losses of glutamate. We have simulated the performance of this sequence for glutamate and used it to quantitatively measure glutamate in the human hippocampus using a linear components model. Using tissue segmentation and regression analysis, we measured a glutamate concentration of 8.8 +/- 2.1 mM in hippocampal and temporal gray matter and 3.7 +/- 1.1 mM in temporal white matter (95% CI). We have used this approach in a small group of patients (n = 5) with unilateral hippocampal epilepsy.
Collapse
Affiliation(s)
- J W Pan
- Magnetic Resonance Research Center and Department of Neurology, Albert Einstein College of Medicine, Bronx, New York 10461, USA.
| | | | | | | |
Collapse
|
23
|
Choi C, Ogilvie CJ, Malykhin N, Ngo JTV, Hartfeil MAW, Coupland NJ. Detection of the myo-inositol 4.06-ppm resonance by selective J rewinding: application to human prefrontal cortex in vivo. Magn Reson Med 2006; 54:1536-40. [PMID: 16215961 DOI: 10.1002/mrm.20688] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
A new proton NMR single-voxel spectral editing strategy for the rapid measurement of myo-inositol in human brain is proposed. The spectral editing detects the 4.06-ppm, weakly coupled resonance by means of selective J rewinding. An 84.6-ms-long quadruple-resonance selective 180 degrees radiofrequency pulse, implemented within an adiabatic-refocused localization sequence, induces an in-phase triplet at 4.06 ppm, while eliminating the contribution from creatine, phosphorylethanolamine, lactate, and serine in this spectral region. The myo-inositol concentration in human prefrontal cortex is estimated to be 5.7 +/- 0.9 mumol/g (mean +/- SD, n = 7), with reference to NAA at 10 micromol/g.
Collapse
Affiliation(s)
- Changho Choi
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada.
| | | | | | | | | | | |
Collapse
|
24
|
Choi C, Coupland NJ, Bhardwaj PP, Malykhin N, Gheorghiu D, Allen PS. Measurement of brain glutamate and glutamine by spectrally-selective refocusing at 3 tesla. Magn Reson Med 2006; 55:997-1005. [PMID: 16598736 DOI: 10.1002/mrm.20875] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A new single-voxel proton NMR spectrally-selective refocusing method for measuring glutamate (Glu) and glutamine (Gln) in the human brain in vivo at 3T is reported. Triple-resonance selective 180 degrees RF pulses with a bandwidth of 12 Hz were implemented within point-resolved spectroscopy (PRESS) for selective detection of Glu or Gln, and simultaneous acquisition of creatine singlets for use as a reference in phase correction. The carriers of the spectrally-selective 180 degrees pulses and the echo times (TEs) were optimized with both numerical and experimental analyses of the filtering performance, which enabled measurements of the target metabolites with negligible contamination from N-acetylaspartate and glutathione. The concentrations of Glu and Gln in the prefrontal cortex were estimated to be 9.7+/-0.5 and 3.0+/-0.7 mM (mean+/-SD, N=7), with reference to Cr at 8 mM.
Collapse
Affiliation(s)
- Changho Choi
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada.
| | | | | | | | | | | |
Collapse
|
25
|
Knight-Scott J, Shanbhag DD, Dunham SA. A phase rotation scheme for achieving very short echo times with localized stimulated echo spectroscopy. Magn Reson Imaging 2005; 23:871-6. [PMID: 16275426 DOI: 10.1016/j.mri.2005.07.004] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2004] [Accepted: 07/07/2005] [Indexed: 11/29/2022]
Abstract
In a single-voxel stimulated echo localization sequence in magnetic resonance spectroscopy, magnetic field gradients are inserted within the echo time (TE) to filter signals generated through coherence pathways other than that leading to the stimulated echo. There is a significant penalty for these gradients as they increase the minimum TE, thereby leading to significant signal loss from spin-spin relaxation and phase distortions in coupled spin systems. Here, an RF phase rotation technique is described for a stimulated echo localization sequence that allows removal of the gradients in the TE intervals and, subsequently, reduction of the minimum TE to only 6 ms. Experiments carried out on six healthy volunteers on a 1.5-T whole-body MR system show a significant signal increase in the metabolite concentrations when measured with a 6-ms TE (N-acetyl-aspartate, 12%, P=.002; creatine, 15%, P=.04; and glutamate+glutamine, 92%, P=.02) compared to concentrations measured with data collected at TEs of 15 and 20 ms.
Collapse
Affiliation(s)
- Jack Knight-Scott
- Department of Biomedical Engineering, University of Virginia Health System, Charlottesville, VA 22908-0759, USA.
| | | | | |
Collapse
|