1
|
Ali SM, van Zijl PC, Prasuhn J, Wirestam R, Knutsson L, Yadav NN. Machine learning-based multi-pool Voigt fitting of CEST, rNOE, and MTC in Z-spectra. Magn Reson Med 2025; 94:346-361. [PMID: 39963087 PMCID: PMC12021569 DOI: 10.1002/mrm.30460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2024] [Revised: 01/15/2025] [Accepted: 01/21/2025] [Indexed: 02/27/2025]
Abstract
PURPOSE Four-pool Voigt (FPV) machine learning (ML)-based fitting for Z-spectra was developed to reduce fitting times for clinical feasibility in terms of on-scanner analysis and to promote larger cohort studies. The approach was compared to four-pool Lorentzian (FPL)-ML-based modeling to empirically verify the advantage of Voigt models for Z-spectra. METHODS Voigt and Lorentzian models were fitted to human 3 T Z-spectral data using least squares (LS) to generate training data for the corresponding ML versions. Gradient boosting decision trees were trained, resulting in one Voigt and one Lorentzian ML model. Modeling accuracy was tested, and the fitting times of the ML models and LS versions were evaluated. The goodness of fits of Voigt and Lorentzian ML models were compared. RESULTS The training time for each ML model (Voigt and Lorentzian) was less than 1 min, and the modeling accuracy compared to the corresponding LS versions was excellent, as indicated by a nonsignificant difference between the parameters obtained by LS and corresponding ML versions. The average fitting time was 20 μs/spectrum for both ML models compared to 0.27 and 0.82 s/spectrum for LS with FPL and FPV, respectively. The goodness of fits of FPV-ML and FPL-ML differed significantly (p < 0.005), with FPV-ML showing an improvement for all tested data. CONCLUSION Gradient boosting decision trees fitting of multi-pool Z-spectra significantly reduces fitting times compared to traditional LS approaches, allowing fast data processing while upholding fitting quality. Along with the short training times, this makes the method suitable for clinical settings and for large cohort research applications. The FPV-ML approach provides a significant improvement of goodness of fit compared to FPL-ML.
Collapse
Affiliation(s)
| | - Peter C.M. van Zijl
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, United States
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, United States
| | - Jannik Prasuhn
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, United States
- Department of Neurology, University Medical Center Schleswig-Holstein, Campus Lübeck, Germany
- Institute of Neurogenetics, University of Lübeck, Germany
- Center for Brain, Behavior and Metabolism, University of Lübeck, Germany
- Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, Maryland, United States
| | - Ronnie Wirestam
- Department of Medical Radiation Physics, Lund University, Lund, Sweden
| | - Linda Knutsson
- Department of Medical Radiation Physics, Lund University, Lund, Sweden
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, United States
- Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, Maryland, United States
| | - Nirbhay N. Yadav
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, United States
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, United States
| |
Collapse
|
2
|
Tao Q, Zhang Q, An Z, Chen Z, Feng Y. Multi-Parametric MRI for Evaluating Variations in Renal Structure, Function, and Endogenous Metabolites in an Animal Model With Acute Kidney Injury Induced by Ischemia Reperfusion. J Magn Reson Imaging 2024; 60:245-255. [PMID: 37881827 DOI: 10.1002/jmri.29094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Revised: 10/12/2023] [Accepted: 10/12/2023] [Indexed: 10/27/2023] Open
Abstract
BACKGROUND Ischemia reperfusion injury (IRI)-induced acute kidney injury (AKI) may occur after renal ischemic injury. There is a lack of an accurate and comprehensive detection technique for IRI-AKI. PURPOSE To longitudinally evaluate IRI-AKI in rats by renal structure, function, and metabolites using multi-parametric MRI (mpMRI). STUDY TYPE Prospective. ANIMAL MODEL Forty-eight rats undergoing IRI-AKI. FIELD STRENGTH/SEQUENCE 7-T, T1 mapping, and arterial spin labeling (ASL): echo planar imaging (EPI) sequence; blood oxygen level-dependent (BOLD): gradient recalled echo (GRE) sequence; T2 mapping, quantitative magnetization transfer (qMT), and chemical exchange saturation transfer (CEST): rapid acquisition with relaxation enhancement (RARE) sequence. ASSESSMENT The mpMRI for IRI-AKI was conducted at 0 (control), 1, 3, 7, 14, and 28 days, all included eight rats. The longitudinal mpMRI signal of manually outlined cortex, outer stripe of the outer medulla (OSOM), inner stripe of the outer medulla, and medulla plus pelvis were calculated and compared, their diagnosis performance for IRI-AKI also been evaluated. STATISTICAL TESTS Pearson correlations analysis for correlation between mpMRI signal and renal injury, unpaired t-tests for comparing the signal changes, and receiver operating characteristics (ROC) analysis was used to identify most sensitive indicator of mpMRI. A P-value <0.05 was considered statistically significant. RESULTS Compared with control kidneys, the T1 and T2 values of the cortex and medulla in IRI kidneys increased and reached their highest values on day 14, and the kidneys also showed the most severe edema and segments blurred. The RBF in the cortex and OSOM showed a significant decline after day 3. The BOLD signal in the OSOM largest increased on day 28. The cortical PSR and the amine-CEST both decreased with IRI-AKI progression, and amine-CEST achieved the highest AUC for the diagnosis (0.899). DATA CONCLUSION Multi-parametric MRI may show comprehensive variations in IRI-AKI, and amine-CEST may exhibit the highest accuracy for diagnosis of IRI-AKI. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Quan Tao
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
- Guangdong Provincial Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
| | - Qianqian Zhang
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
- Guangdong Provincial Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
| | - Ziqi An
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
- Guangdong Provincial Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
| | - Zelong Chen
- Medical Imaging Center, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Yanqiu Feng
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
- Guangdong Provincial Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
| |
Collapse
|
3
|
Shaghaghi M, Cai K. Analytical solution of the Bloch-McConnell equations for steady-state CEST Z-spectra. Magn Reson Imaging 2024; 109:74-82. [PMID: 38430977 PMCID: PMC11463197 DOI: 10.1016/j.mri.2024.02.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 02/22/2024] [Accepted: 02/23/2024] [Indexed: 03/05/2024]
Abstract
PURPOSE To derive an analytic expression for the steady-state Chemical Exchange Saturation Transfer (CEST) Z-spectra of a two-pool proton-exchanging system, facilitating simulations and expedited fitting of steady-state Z-spectra. METHOD The analytical expression is derived by directly solving the set of Bloch-McConnell differential equations in matrix form for a two-pool exchanging system, determining water magnetization under steady-state saturation across the entire Z-spectrum. The analytic solution is compared and validated against the numerical solution of Bloch-McConnell equations under prolonged saturation. The study also explores the line shape of a CEST peak, interpolating under-sampled Z-spectra, and Z-spectral fitting in the presence of noise. RESULTS The derived analytic solution accurately reproduces spectra obtained through numerical solutions. Direct fitting of simulated CEST spectra with the analytical solution yields the physical parameters of the exchanging system. The study shows that the analytical solution enables the reproduction of fully sampled spectra from sparsely sampled Z-spectra. Additionally, it confirms the approximation of the CEST spectrum of a single exchanging proton species with a Lorentzian function. Monte Carlo simulations reveal that the accuracy and precision of Z-spectral fittings for physical parameters are significantly influenced by data noise. The study also derives and discusses the analytical solution for three-pool Z-spectra. CONCLUSION The derived analytic solution for steady state Z-spectra can be utilized for simulations and Z-spectrum fitting, significantly reducing fitting times compared to numerical methods employed for fitting CEST Z-spectra.
Collapse
Affiliation(s)
- Mehran Shaghaghi
- Department of Radiology, University of Illinois at Chicago, Chicago, IL 60612, USA
| | - Kejia Cai
- Department of Radiology, University of Illinois at Chicago, Chicago, IL 60612, USA; Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA.
| |
Collapse
|
4
|
Sun C, Zhao Y, Zu Z. Validation of the presence of fast exchanging amine CEST effect at low saturation powers and its influence on the quantification of APT. Magn Reson Med 2023; 90:1502-1517. [PMID: 37317709 PMCID: PMC10614282 DOI: 10.1002/mrm.29742] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 05/16/2023] [Accepted: 05/17/2023] [Indexed: 06/16/2023]
Abstract
PURPOSE Accurately quantifying the amide proton transfer (APT) effect and the underlying exchange parameters is crucial for its applications, but previous studies have reported conflicting results. In these quantifications, the CEST effect from the fast exchange amine was always ignored because it was considered weak with low saturation powers. This paper aims to evaluate the influence of the fast exchange amine CEST on the quantification of APT at low saturation powers. METHODS A quantification method with low and high saturation powers was used to distinguish APT from the fast exchange amine CEST effect. Simulations were conducted to assess the method's capability to separate APT from the fast exchange amine CEST effect. Animal experiments were performed to assess the relative contributions from the fast exchange amine and amide to CEST signals at 3.5 ppm. Three APT quantification methods, each with varying degrees of contamination from the fast exchange amine, were employed to process the animal data to assess the influence of the amine on the quantification of APT effect and the exchange parameters. RESULTS The relative size of the fast exchange amine CEST effect to APT effect gradually increases with increasing saturation power. At 9.4 T, it increases from approximately 20% to 40% of APT effect with a saturation power increase from 0.25 to 1 μT. CONCLUSION The fast exchange amine CEST effect leads overestimation of APT effect, fitted amide concentration, and amide-water exchange rate, potentially contributing to the conflicting results reported in previous studies.
Collapse
Affiliation(s)
- Casey Sun
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, US
- Department of Chemistry, University of Florida, Gainesville, US
| | - Yu Zhao
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
- Department of Biomedical Engineering, Vanderbilt University, Nashville, US
| |
Collapse
|
5
|
Cohen O, Otazo R. Global deep learning optimization of chemical exchange saturation transfer magnetic resonance fingerprinting acquisition schedule. NMR IN BIOMEDICINE 2023; 36:e4954. [PMID: 37070221 PMCID: PMC10896067 DOI: 10.1002/nbm.4954] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 04/10/2023] [Accepted: 04/11/2023] [Indexed: 05/06/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI is a promising molecular imaging technique but suffers from long scan times and complicated processing. CEST was recently combined with magnetic resonance fingerprinting (MRF) to address these shortcomings. However, the CEST-MRF signal depends on multiple acquisition and tissue parameters so selecting an optimal acquisition schedule is challenging. In this work, we propose a novel dual-network deep learning framework to optimize the CEST-MRF acquisition schedule. The quality of the optimized schedule was assessed in a digital brain phantom and compared with alternate deep learning optimization approaches. The effect of schedule length on the reconstruction error was also investigated. A healthy subject was scanned with optimized and random schedules and with a conventional CEST sequence for comparison. The optimized schedule was also tested in a subject with metastatic renal cell carcinoma. Reproducibility was assessed via test-retest experiments and the concordance correlation coefficient calculated for white matter (WM) and grey matter (GM). The optimized schedule was 12% shorter but yielded equal or lower normalized root mean square error for all parameters. The proposed optimization also provided a lower error compared with alternate methodologies. Longer schedules generally yielded lower error. In vivo maps obtained with the optimized schedule showed reduced noise and improved delineation of GM and WM. CEST curves synthesized from the optimized parameters were highly correlated (r = 0.99) with measured conventional CEST. The mean concordance correlation coefficient in WM/GM for all tissue parameters was 0.990/0.978 for the optimized schedule but only 0.979/0.975 for the random schedule. The proposed schedule optimization is widely applicable to MRF pulse sequences and provides accurate and reproducible tissue maps with reduced noise at a shorter scan time than a randomly generated schedule.
Collapse
Affiliation(s)
- Ouri Cohen
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Ricardo Otazo
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| |
Collapse
|
6
|
Kim H, Kim J, Sun PZ. CEST2022 - mapping multi-pool CEST signal changes in an animal model of brain tumor with quasi-steady-state reconstruction-empowered CEST quantification. Magn Reson Imaging 2023:S0730-725X(23)00100-5. [PMID: 37321379 DOI: 10.1016/j.mri.2023.06.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Accepted: 06/12/2023] [Indexed: 06/17/2023]
Abstract
Chemical exchange saturated transfer (CEST) MRI has biomarker potential to assess tissue microenvironment in brain tumors. Multi-pool Lorentzian or spinlock models provides useful insights into the CEST contrast mechanism. However, T1 contribution to the complex overlapping effects of brain tumors is difficult under the non-equilibrium state. Therefore, this study evaluated T1 contributions on multi-pool parameters with quasi-steady-state (QUASS) algorithm reconstructed equilibrium data. MRI scans were performed in rat brain tumor models, including relaxation, diffusion, and CEST imaging. A pixel-wise seven-pool spinlock-model was employed to fit QUASS reconstructed CEST Z-spectra and evaluated the magnetization transfer (MT), amide, amine, guanidyl, and nuclear-overhauled effect (NOE) signals in tumor and normal tissues. In addition, T1 was estimated from the spinlock-model fitting and compared with measured T1. We observed tumor had a statistically significant increase in the amide signal (p < 0.001) and decreases in the MT and NOE signals (p < 0.001). On the other hand, the differences in amine and guanidyl between the tumor and contralateral normal regions were not statistically significant. The differences between measured and estimated T1 values were 8% in the normal tissue and 4% in the tumor. Furthermore, the isolated MT signal strongly correlated with R1 (r = 0.96, P < 0.001). In summary, we successfully unraveled multi-factorial effects in the CEST signal using spinlock-model fitting and QUASS method and demonstrated the effect of T1 relaxation on MT and NOE.
Collapse
Affiliation(s)
- Hahnsung Kim
- Emory National Primate Research Center, Emory University, Atlanta, GA, United States of America; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States of America.
| | - Jinsuh Kim
- Emory National Primate Research Center, Emory University, Atlanta, GA, United States of America; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States of America
| | - Phillip Zhe Sun
- Emory National Primate Research Center, Emory University, Atlanta, GA, United States of America; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States of America.
| |
Collapse
|
7
|
Igarashi T, Kim H, Sun PZ. Detection of tissue pH with quantitative chemical exchange saturation transfer magnetic resonance imaging. NMR IN BIOMEDICINE 2023; 36:e4711. [PMID: 35141979 PMCID: PMC10249910 DOI: 10.1002/nbm.4711] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 02/03/2022] [Accepted: 02/05/2022] [Indexed: 05/12/2023]
Abstract
Chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) has emerged as a novel means for sensitive detection of dilute labile protons and chemical exchange rates. By sensitizing to pH-dependent chemical exchange, CEST MRI has shown promising results in monitoring tissue statuses such as pH changes in disorders like acute stroke, tumor, and acute kidney injury. This article briefly reviews the basic principles for CEST imaging and quantitative measures, from the simplistic asymmetry analysis to multipool Lorentzian decoupling and quasi-steady-state reconstruction. In particular, the advantages and limitations of commonly used quantitative approaches for CEST applications are discussed.
Collapse
Affiliation(s)
- Takahiro Igarashi
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA
| | - Hahnsung Kim
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA
| | - Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA
| |
Collapse
|
8
|
Sun PZ. Demonstration of accurate multi-pool chemical exchange saturation transfer MRI quantification - Quasi-steady-state reconstruction empowered quantitative CEST analysis. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 348:107379. [PMID: 36689786 PMCID: PMC10023465 DOI: 10.1016/j.jmr.2023.107379] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 01/05/2023] [Accepted: 01/15/2023] [Indexed: 05/18/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI is sensitive to dilute labile protons and microenvironment properties, yet CEST quantification has been challenging. This difficulty is because the CEST measurement depends not only on the underlying CEST system but also on the scan protocols, including RF saturation amplitude, duration, and repetition time. In addition, T1 normalization is not straightforward under non-equilibrium conditions. Recently, a quasi-steady-state (QUASS) algorithm was established to reconstruct the desired equilibrium state from experimental measurements. Our study aimed to determine the accuracy of spinlock-model-based multi-pool CEST quantification using numerical simulations and phantom experiments. In short, CEST Z-spectra were simulated for a representative 3-pool model, and CEST amplitudes were solved with spinlock model-based multi-pool fitting and assessed as a function of RF saturation time (Ts), repetition time (TR), and T1. Although the apparent CEST signals showed significant T1 dependence, such relationships were not observed following QUASS reconstruction. To test the accuracy of T1 correction, a multi-vial phantom of nicotinamide and creatine was doped with manganese chloride, resulting in T1 ranging from 1 s to beyond 2 s. The multi-labile signals determined from the routine measurements showed significant dependence on Ts, TR, and T1. In contrast, CEST signals from the QUASS reconstruction showed consistent quantification independent of such variables. To summarize, our study demonstrated that accurate CEST quantification is feasible in multi-pool CEST systems with the spinlock-model-based fitting of QUASS CEST MRI.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, GA, United States; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States.
| |
Collapse
|
9
|
Ji Y, Lu D, Sun PZ, Zhou IY. In vivo pH mapping with omega plot-based quantitative chemical exchange saturation transfer MRI. Magn Reson Med 2023; 89:299-307. [PMID: 36089834 PMCID: PMC9617761 DOI: 10.1002/mrm.29444] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 08/05/2022] [Accepted: 08/15/2022] [Indexed: 02/01/2023]
Abstract
PURPOSE Chemical exchange saturation transfer (CEST) MRI is promising for detecting dilute metabolites and microenvironment properties, which has been increasingly adopted in imaging disorders such as acute stroke and cancer. However, in vivo CEST MRI quantification remains challenging because routine asymmetry analysis (MTRasym ) or Lorentzian decoupling measures a combined effect of the labile proton concentration and its exchange rate. Therefore, our study aimed to quantify amide proton concentration and exchange rate independently in a cardiac arrest-induced global ischemia rat model. METHODS The amide proton CEST (APT) effect was decoupled from tissue water, macromolecular magnetization transfer, nuclear Overhauser enhancement, guanidinium, and amine protons using the image downsampling expedited adaptive least-squares (IDEAL) fitting algorithm on Z-spectra obtained under multiple RF saturation power levels, before and after global ischemia. Omega plot analysis was applied to determine amide proton concentration and exchange rate simultaneously. RESULTS Global ischemia induces a significant APT signal drop from intact tissue. Using the modified omega plot analysis, we found that the amide proton exchange rate decreased from 29.6 ± 5.6 to 12.1 ± 1.3 s-1 (P < 0.001), whereas the amide proton concentration showed little change (0.241 ± 0.035% vs. 0.202 ± 0.034%, P = 0.074) following global ischemia. CONCLUSION Our study determined the labile proton concentration and exchange rate underlying the in vivo APT MRI. The significant change in the exchange rate, but not the concentration of amide proton demonstrated that the pH effect dominates the APT contrast during tissue ischemia.
Collapse
Affiliation(s)
- Yang Ji
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
- Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Dongshuang Lu
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| | - Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
- Emory Primate Imaging Center, Emory Primate Research Center, Emory University, Atlanta, GA, USA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA
| | - Iris Y. Zhou
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| |
Collapse
|
10
|
Msayib Y, Harston GWJ, Ray KJ, Larkin JR, Sutherland BA, Sheerin F, Blockley NP, Okell TW, Jezzard P, Baldwin A, Sibson NR, Kennedy J, Chappell MA. Quantitative chemical exchange saturation transfer imaging of nuclear overhauser effects in acute ischemic stroke. Magn Reson Med 2022; 88:341-356. [PMID: 35253936 PMCID: PMC9314583 DOI: 10.1002/mrm.29187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 01/13/2022] [Accepted: 01/17/2022] [Indexed: 11/07/2022]
Abstract
PURPOSE In chemical exchange saturation transfer imaging, saturation effects between - 2 to - 5 ppm (nuclear Overhauser effects, NOEs) have been shown to exhibit contrast in preclinical stroke models. Our previous work on NOEs in human stroke used an analysis model that combined NOEs and semisolid MT; however their combination might feasibly have reduced sensitivity to changes in NOEs. The aim of this study was to explore the information a 4-pool Bloch-McConnell model provides about the NOE contribution in ischemic stroke, contrasting that with an intentionally approximate 3-pool model. METHODS MRI data from 12 patients presenting with ischemic stroke were retrospectively analyzed, as well as from six animals induced with an ischemic lesion. Two Bloch-McConnell models (4 pools, and a 3-pool approximation) were compared for their ability to distinguish pathological tissue in acute stroke. The association of NOEs with pH was also explored, using pH phantoms that mimic the intracellular environment of naïve mouse brain. RESULTS The 4-pool measure of NOEs exhibited a different association with tissue outcome compared to 3-pool approximation in the ischemic core and in tissue that underwent delayed infarction. In the ischemic core, the 4-pool measure was elevated in patient white matter ( 1 . 20 ± 0 . 20 ) and in animals ( 1 . 27 ± 0 . 20 ). In the naïve brain pH phantoms, significant positive correlation between the NOE and pH was observed. CONCLUSION Associations of NOEs with tissue pathology were found using the 4-pool metric that were not observed using the 3-pool approximation. The 4-pool model more adequately captured in vivo changes in NOEs and revealed trends depending on tissue pathology in stroke.
Collapse
Affiliation(s)
- Yunus Msayib
- Institute of Biomedical Engineering, Department of Engineering ScienceUniversity of OxfordOxfordUK
| | - George W. J. Harston
- Acute Vascular Imaging Centre, Radcliffe Department of MedicineUniversity of OxfordOxfordUK
| | - Kevin J. Ray
- Wellcome Centre for Integrative Neuroimaging, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUK
| | - James R. Larkin
- Department of Oncology, CRUK and MRC Oxford Institute for Radiation OncologyUniversity of OxfordOxfordUK
| | - Brad A. Sutherland
- Acute Vascular Imaging Centre, Radcliffe Department of MedicineUniversity of OxfordOxfordUK
- School of MedicineUniversity of TasmaniaHobartTasmaniaAustralia
| | - Fintan Sheerin
- Acute Vascular Imaging Centre, Radcliffe Department of MedicineUniversity of OxfordOxfordUK
| | - Nicholas P. Blockley
- Wellcome Centre for Integrative Neuroimaging, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUK
| | - Thomas W. Okell
- Wellcome Centre for Integrative Neuroimaging, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUK
| | - Peter Jezzard
- Wellcome Centre for Integrative Neuroimaging, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUK
| | | | - Nicola R. Sibson
- Department of Oncology, CRUK and MRC Oxford Institute for Radiation OncologyUniversity of OxfordOxfordUK
| | - James Kennedy
- Acute Vascular Imaging Centre, Radcliffe Department of MedicineUniversity of OxfordOxfordUK
| | - Michael A. Chappell
- Wellcome Centre for Integrative Neuroimaging, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUK
- Sir Peter Mansfield Imaging Center, School of MedicineUniversity of NottinghamNottinghamUK
- Mental Health & Clinical Neuroscience, School of Medicine, University of NottinghamNottinghamUK
| |
Collapse
|
11
|
McHugh CT, Kelley M, Bryden NJ, Branca RT. In vivo hyperCEST imaging: Experimental considerations for a reliable contrast. Magn Reson Med 2022; 87:1480-1489. [PMID: 34601738 PMCID: PMC8776610 DOI: 10.1002/mrm.29032] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 08/31/2021] [Accepted: 09/14/2021] [Indexed: 12/20/2022]
Abstract
PURPOSE HyperCEST contrast relies on the reduction of the solvent signal after selective saturation of the solute magnetization. The scope of this work is to outline the experimental conditions needed to obtain a reliable hyperCEST contrast in vivo, where the "solvent" signal (ie, the dissolved-phase signal) may change over time due to the increase in xenon (Xe) accumulation into tissue. METHODS Hyperpolarized 129 Xe was delivered to mice at a constant volume and rate using a mechanical ventilator, which triggered the saturation, excitation, and acquisition of the MR signal during the exhale phase of the breath cycle-either every breath or every 2, 3, or 4 breaths. Serial Z-spectra and hyperCEST images were acquired before and after a bolus injection of cucurbit[6]uril to assess possible signal fluctuations and instabilities. RESULTS The intensity of the dissolved-phase Xe signal was observed to first increase immediately after the beginning of the hyperpolarized gas inhalation and NMR acquisition, and then decrease before reaching a steady-state condition. Once a steady-state dissolved-phase magnetization was established, a reliable hyperCEST contrast, exceeding 40% signal reduction, was observed. CONCLUSION A reliable hyperCEST contrast can only be obtained after establishing a steady-state dissolved phase 129 Xe magnetization. Under stable physiological conditions, a steady-state dissolved-phase Xe magnetization is only achieved after a series of Xe inhalations and RF excitations, and it requires synchronization of the breathing rate with the MR acquisition.
Collapse
Affiliation(s)
- Christian T McHugh
- Department of Physics and Astronomy, The University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America,Biomedical Research Imaging Center, The University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America
| | - Michele Kelley
- Department of Physics and Astronomy, The University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America,Biomedical Research Imaging Center, The University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America
| | - Nicholas J Bryden
- Department of Physics and Astronomy, The University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America,Biomedical Research Imaging Center, The University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America
| | - Rosa T Branca
- Department of Physics and Astronomy, The University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America,Biomedical Research Imaging Center, The University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America
| |
Collapse
|
12
|
O'Grady KP, Satish S, Owen QR, Box BA, Bagnato F, Combes AJE, Cook SR, Westervelt HJ, Feiler HR, Lawless RD, Sarma A, Malone SD, Ndolo JM, Yoon K, Dortch RD, Rogers BP, Smith SA. Relaxation-Compensated Chemical Exchange Saturation Transfer MRI in the Brain at 7T: Application in Relapsing-Remitting Multiple Sclerosis. Front Neurol 2022; 13:764690. [PMID: 35299614 PMCID: PMC8923037 DOI: 10.3389/fneur.2022.764690] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 02/01/2022] [Indexed: 11/16/2022] Open
Abstract
Chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) can probe tissue biochemistry in vivo with high resolution and sensitivity without requiring exogenous contrast agents. Applying CEST MRI at ultrahigh field provides advantages of increasing spectral resolution and improving sensitivity to metabolites with faster proton exchange rates such as glutamate, a critical neurotransmitter in the brain. Prior magnetic resonance spectroscopy and CEST MRI studies have revealed altered regulation of glutamate in patients with multiple sclerosis (MS). While CEST imaging facilitates new strategies for investigating the pathology underlying this complex and heterogeneous neurological disease, CEST signals are contaminated or diluted by concurrent effects (e.g., semi-solid magnetization transfer (MT) and direct water saturation) and are scaled by the T1 relaxation time of the free water pool which may also be altered in the context of disease. In this study of 20 relapsing-remitting MS patients and age- and sex-matched healthy volunteers, glutamate-weighted CEST data were acquired at 7.0 T. A Lorentzian fitting procedure was used to remove the asymmetric MT contribution from CEST z-spectra, and the apparent exchange-dependent relaxation (AREX) correction was applied using an R1 map derived from an inversion recovery sequence to further isolate glutamate-weighted CEST signals from concurrent effects. Associations between AREX and cognitive function were examined using the Minimal Assessment of Cognitive Function in MS battery. After isolating CEST effects from MT, direct water saturation, and T1 effects, glutamate-weighted AREX contrast remained higher in gray matter than in white matter, though the difference between these tissues decreased. Glutamate-weighted AREX in normal-appearing gray and white matter in MS patients did not differ from healthy gray and white matter but was significantly elevated in white matter lesions. AREX in some cortical regions and in white matter lesions correlated with disability and measures of cognitive function in MS patients. However, further studies with larger sample sizes are needed to confirm these relationships due to potential confounding effects. The application of MT and AREX corrections in this study demonstrates the importance of isolating CEST signals for more specific characterization of the contribution of metabolic changes to tissue pathology and symptoms in MS.
Collapse
Affiliation(s)
- Kristin P. O'Grady
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, United States
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Sanjana Satish
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Quinn R. Owen
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Bailey A. Box
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Francesca Bagnato
- Neuroimaging Unit, Division of Neuroimmunology, Department of Neurology, Vanderbilt University Medical Center, Nashville, TN, United States
- Department of Neurology, Nashville VA Medical Center, TN Valley Healthcare System, Nashville, TN, United States
| | - Anna J. E. Combes
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, United States
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Sarah R. Cook
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Holly James Westervelt
- Division of Behavioral and Cognitive Neurology, Department of Neurology, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Haley R. Feiler
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Richard D. Lawless
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Asha Sarma
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Shekinah D. Malone
- School of Medicine, Meharry Medical College, Nashville, TN, United States
| | - Josephine M. Ndolo
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Keejin Yoon
- Neuroimaging Unit, Division of Neuroimmunology, Department of Neurology, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Richard D. Dortch
- Department of Translational Neuroscience, Barrow Neurological Institute, Phoenix, AZ, United States
| | - Baxter P. Rogers
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, United States
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, United States
- Department of Psychiatry and Behavioral Sciences, Vanderbilt University Medical Center, Nashville, TN, United States
- Biomedical Engineering, Vanderbilt University, Nashville, TN, United States
| | - Seth A. Smith
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, United States
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, United States
- Biomedical Engineering, Vanderbilt University, Nashville, TN, United States
| |
Collapse
|
13
|
Lankford CL, Louie EA, Zu Z, Does MD, Gochberg DF. A hybrid numeric-analytic solution for pulsed CEST. NMR IN BIOMEDICINE 2022; 35:e4610. [PMID: 34636458 PMCID: PMC9045009 DOI: 10.1002/nbm.4610] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 07/23/2021] [Accepted: 08/12/2021] [Indexed: 05/08/2023]
Abstract
Chemical exchange saturation transfer (CEST) methods measure the effect of magnetization exchange between solutes and water. While CEST methods are often implemented using a train of off-resonant shaped RF pulses, they are typically analyzed as if the irradiation were continuous. This approximation does not account for exchange of rotated magnetization, unique to pulsed irradiation and exploited by chemical exchange rotation transfer methods. In this work, we derive and test an analytic solution for the steady-state water signal under pulsed irradiation by extending a previous work to include the effects of pulse shape. The solution is largely accurate at all offsets, but this accuracy diminishes at higher exchange rates and when applying pulse shapes with large root-mean-squared to mean ratios (such as multi-lobe sinc pulses).
Collapse
Affiliation(s)
- Christopher L. Lankford
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN, USA
| | - Elizabeth A. Louie
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN, USA
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN, USA
| | - Mark D. Does
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
- Department of Electrical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Daniel F. Gochberg
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN, USA
- Department of Physics and Astronomy, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|
14
|
Kim H, Wu Y, Villano D, Longo DL, McMahon MT, Sun PZ. Analysis Protocol for the Quantification of Renal pH Using Chemical Exchange Saturation Transfer (CEST) MRI. Methods Mol Biol 2021; 2216:667-688. [PMID: 33476030 PMCID: PMC9703203 DOI: 10.1007/978-1-0716-0978-1_40] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
Abstract
The kidney plays a major role in maintaining body pH homeostasis. Renal pH, in particular, changes immediately following injuries such as intoxication and ischemia, making pH an early biomarker for kidney injury before the symptom onset and complementary to well-established laboratory tests. Because of this, it is imperative to develop minimally invasive renal pH imaging exams and test pH as a new diagnostic biomarker in animal models of kidney injury before clinical translation. Briefly, iodinated contrast agents approved by the US Food and Drug Administration (FDA) for computed tomography (CT) have demonstrated promise as novel chemical exchange saturation transfer (CEST) MRI agents for pH-sensitive imaging. The generalized ratiometric iopamidol CEST MRI analysis enables concentration-independent pH measurement, which simplifies in vivo renal pH mapping. This chapter describes quantitative CEST MRI analysis for preclinical renal pH mapping, and their application in rodents, including normal conditions and acute kidney injury.This publication is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This analysis protocol chapter is complemented by two separate chapters describing the basic concepts and experimental procedure.
Collapse
Affiliation(s)
- Hahnsung Kim
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA, USA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA
| | - Yin Wu
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Daisy Villano
- Department of Molecular Biotechnology and Health Sciences, University of Torino, Torino, Italy
| | - Dario Livio Longo
- Institute of Biostructures and Bioimaging (IBB), Italian National Research Council (CNR), Torino, Italy
| | - Michael T McMahon
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
- The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Phillip Zhe Sun
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA, USA.
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA.
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA.
| |
Collapse
|
15
|
Damen FC, Tain RW, Thomas R, Li W, Tai L, Cai K. Evaluation of B 0-correction of relative CBF maps using tagging distance dependent Z-spectrum (TADDZ). Magn Reson Imaging 2019; 65:83-89. [PMID: 31669538 DOI: 10.1016/j.mri.2019.10.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Revised: 08/27/2019] [Accepted: 10/08/2019] [Indexed: 12/17/2022]
Abstract
Arterial spin labeling (ASL) MRI, based on endogenous contrast from blood water, is used in research and diagnosis of cerebral vascular conditions. However, artifacts due to imperfect imaging conditions such as B0-inhomogeneity (ΔB0) could lead to variations in the quantification of relative cerebral blood flow (CBF). In this study, we evaluate a new approach using tagging distance dependent Z-spectrum (TADDZ) data, similar to the ΔB0 corrections in the chemical exchange saturation transfer (CEST) experiments, to remove the imaging plane B0 inhomogeneity induced CBF artifacts in ASL MRI. Our results indicate that imaging-plane B0-inhomogeneity can lead to variations and errors in the relative CBF maps especially under small tagging distances. Along with an acquired B0 map, TADDZ data helps to eliminate B0-inhomogeneity induced artifacts in the resulting relative CBF maps. We demonstrated the effective use of TADDZ data to reduce variation while subjected to systematic changes in ΔB0. In addition, TADDZ corrected ASL MRI, with improved consistency, was shown to outperform conventional ASL MRI by differentiating the subtle CBF difference in Alzheimer's disease (AD) mice brains with different APOE genotypes.
Collapse
Affiliation(s)
- Frederick C Damen
- Department of Radiology, University of Illinois at Chicago, Chicago, IL, United States
| | - Rong-Wen Tain
- Department of Radiology, University of Illinois at Chicago, Chicago, IL, United States; Brain Imaging Research, University of California, Irvine, CA, United States
| | - Riya Thomas
- Department of Anatomy and Cell Biology, University of Illinois at Chicago, Chicago, IL, United States
| | - Weigo Li
- Research Resources Center, University of Illinois at Chicago, Chicago, IL, United States; Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, United States; Department of Radiology, Northwestern University, Chicago, IL, United States
| | - Leon Tai
- Department of Anatomy and Cell Biology, University of Illinois at Chicago, Chicago, IL, United States
| | - Kejia Cai
- Department of Radiology, University of Illinois at Chicago, Chicago, IL, United States; Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, United States; Center for MR Research, University of Illinois at Chicago, Chicago, IL, United States.
| |
Collapse
|
16
|
Goldenberg JM, Pagel MD. Assessments of tumor metabolism with CEST MRI. NMR IN BIOMEDICINE 2019; 32:e3943. [PMID: 29938857 PMCID: PMC7377947 DOI: 10.1002/nbm.3943] [Citation(s) in RCA: 63] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 04/13/2018] [Accepted: 04/18/2018] [Indexed: 05/06/2023]
Abstract
Chemical exchange saturation transfer (CEST) is a relatively new contrast mechanism for MRI. CEST MRI exploits a specific MR frequency (chemical shift) of a molecule while generating an image with good spatial resolution using standard MRI techniques, combining the specificity of MRS with the spatial resolution of MRI. Many CEST MRI acquisition methods have been developed to improve analyses of tumor metabolism. GluCEST, CrCEST, and LATEST can map glutamate, creatine, and lactate, which are important metabolites involved in tumor metabolism. GlucoCEST MRI tracks the pharmacokinetics of glucose transport and cell internalization within tumors. CatalyCEST MRI detects enzyme catalysis that changes a substrate CEST agent. AcidoCEST MRI measures extracellular pH of the tumor microenvironment by exploiting a ratio of two pH-dependent CEST signals. This review describes each technique, the technical issues involved with CEST MRI and each specific technique, and the merits and challenges associated with applying each CEST MRI technique to study tumor metabolism.
Collapse
Affiliation(s)
- Joshua M. Goldenberg
- Department of Pharmaceutical Sciences, The University of Arizona, Tucson, AZ, USA
- Department of Cancer Systems Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Mark D. Pagel
- Department of Cancer Systems Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| |
Collapse
|
17
|
Wang R, Wang C, Dai Z, Chen Y, Shen Z, Xiao G, Chen Y, Zhou JN, Zhuang Z, Wu R. An Amyloid-β Targeting Chemical Exchange Saturation Transfer Probe for In Vivo Detection of Alzheimer's Disease. ACS Chem Neurosci 2019; 10:3859-3867. [PMID: 31343167 DOI: 10.1021/acschemneuro.9b00334] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
A reliable and reproducible detection of Aβ deposits would be beneficial for the early diagnosis of Alzheimer's disease (AD). In the present study, the feasibility of applying chemical exchange saturation transfer (CEST) for Aβ deposit detection using angiopep-2 as a probe was evaluated, and it was demonstrated that CEST could detect angiopep-2 and Aβ-angiopep-2 aggregates in vitro. Furthermore, APP/PS1 mice injected with angiopep-2 exhibited a significantly higher in vivo CEST effect when compared with controls. The distribution of Aβ deposits detected by CEST imaging was consistent with the histological staining results. The present study is the first to report a reliable exogenous CEST probe to noninvasively evaluate Aβ deposits in APP/PS1 mice. Furthermore, these results demonstrate the potential for clinical AD diagnosis and Aβ-targeted drug therapy assessment using CEST imaging with the angiopep-2 probe.
Collapse
Affiliation(s)
- Runrun Wang
- Department of Medical Imaging, Second Affiliated Hospital , Shantou University Medical College , Shantou , Guangdong 515000 , P. R. China
| | - Chenwei Wang
- CAS Key Laboratory of Brain Function and Disease, School of Life Sciences , University of Science and Technology of China , Hefei , Anhui 230000 , P. R. China
| | - Zhuozhi Dai
- Department of Medical Imaging, Second Affiliated Hospital , Shantou University Medical College , Shantou , Guangdong 515000 , P. R. China
| | - Yanzi Chen
- Department of Medical Imaging, Second Affiliated Hospital , Shantou University Medical College , Shantou , Guangdong 515000 , P. R. China
| | - Zhiwei Shen
- Department of Medical Imaging, Second Affiliated Hospital , Shantou University Medical College , Shantou , Guangdong 515000 , P. R. China
| | - Gang Xiao
- Department of Mathematics and Statistics , Hanshan Normal University , Chaozhou 515000 , P. R. China
| | - Yuanfeng Chen
- Department of Medical Imaging, Second Affiliated Hospital , Shantou University Medical College , Shantou , Guangdong 515000 , P. R. China
| | - Jiang-Ning Zhou
- CAS Key Laboratory of Brain Function and Disease, School of Life Sciences , University of Science and Technology of China , Hefei , Anhui 230000 , P. R. China
- Center for Excellence in Brain Science and Intelligence Technology , Chinese Academy of Sciences , Shanghai 200031 , China
| | - Zerui Zhuang
- Department of Medical Imaging, Second Affiliated Hospital , Shantou University Medical College , Shantou , Guangdong 515000 , P. R. China
| | - Renhua Wu
- Department of Medical Imaging, Second Affiliated Hospital , Shantou University Medical College , Shantou , Guangdong 515000 , P. R. China
| |
Collapse
|
18
|
Kim B, So S, Park H. Optimization of steady-state pulsed CEST imaging for amide proton transfer at 3T MRI. Magn Reson Med 2019; 81:3616-3627. [DOI: 10.1002/mrm.27674] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2018] [Revised: 01/07/2019] [Accepted: 01/07/2019] [Indexed: 11/08/2022]
Affiliation(s)
- Byungjai Kim
- Department of Electrical Engineering; Korea Advanced Institute of Science and Technology (KAIST); Daejeon Republic of Korea
| | - Seohee So
- Department of Electrical Engineering; Korea Advanced Institute of Science and Technology (KAIST); Daejeon Republic of Korea
| | - Hyunwook Park
- Department of Electrical Engineering; Korea Advanced Institute of Science and Technology (KAIST); Daejeon Republic of Korea
| |
Collapse
|
19
|
Tsitovich PB, Gendron F, Nazarenko AY, Livesay BN, Lopez AP, Shores MP, Autschbach J, Morrow JR. Low-Spin Fe(III) Macrocyclic Complexes of Imidazole-Appended 1,4,7-Triazacyclononane as Paramagnetic Probes. Inorg Chem 2018; 57:8364-8374. [DOI: 10.1021/acs.inorgchem.8b01022] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Pavel B. Tsitovich
- Department of Chemistry, University at Buffalo, State University of New York, Amherst, New York 14260, United States
| | - Frédéric Gendron
- Department of Chemistry, University at Buffalo, State University of New York, Amherst, New York 14260, United States
| | - Alexander Y. Nazarenko
- Chemistry Department, State University of New York, College at Buffalo, 1300 Elmwood Avenue, Buffalo, New York 14222, United States
| | - Brooke N. Livesay
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Alejandra P. Lopez
- Department of Chemistry, University at Buffalo, State University of New York, Amherst, New York 14260, United States
| | - Matthew P. Shores
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Jochen Autschbach
- Department of Chemistry, University at Buffalo, State University of New York, Amherst, New York 14260, United States
| | - Janet R. Morrow
- Department of Chemistry, University at Buffalo, State University of New York, Amherst, New York 14260, United States
| |
Collapse
|
20
|
Zheng Y, Wang X. The Applicability of Amide Proton Transfer Imaging in the Nervous System: Focus on Hypoxic-Ischemic Encephalopathy in the Neonate. Cell Mol Neurobiol 2018; 38:797-807. [PMID: 28942555 PMCID: PMC11481837 DOI: 10.1007/s10571-017-0552-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2017] [Accepted: 09/16/2017] [Indexed: 12/29/2022]
Abstract
In recent years, magnetic resonance imaging (MRI) has become more widely used in neonatal hypoxic-ischemic encephalopathy (HIE), involving, for example, evaluation of cerebral edema, white matter fiber bundle tracking, cerebral perfusion status, and assessment of brain metabolites. MRI has many imaging modalities. However, its application for assessing changes in the internal environment at the tissue and cellular level after hypoxia-ischemia remains a challenge and is currently the focus of intense research. Based on the exchange between amide protons of proteins and polypeptides and free water protons, amide proton transfer (APT) imaging can display changes in pH and protein concentrations in vivo. This paper is a review of the principles of APT imaging, with a focus on the potential application of APT imaging for neonatal HIE.
Collapse
Affiliation(s)
- Yang Zheng
- Department of Radiology, Shengjing Hospital of China Medical University, No. 36, Sanhao Street, Heping District, Shenyang, 110004, People's Republic of China
| | - Xiaoming Wang
- Department of Radiology, Shengjing Hospital of China Medical University, No. 36, Sanhao Street, Heping District, Shenyang, 110004, People's Republic of China.
| |
Collapse
|
21
|
Systematic Evaluation of Amide Proton Chemical Exchange Saturation Transfer at 3 T: Effects of Protein Concentration, pH, and Acquisition Parameters. Invest Radiol 2017; 51:635-46. [PMID: 27272542 DOI: 10.1097/rli.0000000000000292] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
OBJECTIVE The goal of this work was to systematically evaluate the reproducibility of amide proton transfer chemical exchange saturation transfer (APT-CEST) at 3 T and its signal dependence on pH, protein concentration, and acquisition parameters. An in vitro system based on bovine serum albumin (BSA) was used, and its limitations were tested by comparing it to in vivo measurements. The contribution of small endogenous metabolites on the APT-CEST signal at 3 T was also investigated. In addition, the reliability of different z-spectrum interpolations as well as the use of only a few frequency offset data points instead of a whole z-spectrum were tested. MATERIALS AND METHODS We created both a BSA phantom at different concentrations and pH values and a metabolite phantom with different small molecules. Chemical exchange saturation transfer data were acquired using a 2-dimensional fast spoiled gradient-echo sequence with pulsed CEST preparation at different saturation durations and power levels. Healthy volunteer measurements were taken for comparison. Z-spectra were interpolated using a 24th-order polynomial (Poly), an eighth-order Fourier series (Fourier), and a smoothing Spline (sSpline) algorithm. To evaluate reduced data sets, only 6 to 14 frequency offsets of the z-spectrum were used and interpolated via a cubic Spline. Region of interest (ROI) evaluations were used to investigate the reproducibility of amide magnetization transfer ratio asymmetry [MTRasym(3.5 ppm)] and to analyze the MTRasym and z-spectra. RESULTS Interscan standard deviations of MTRasym(3.5 ppm) were always below 0.3%. MTRasym(3.5 ppm) increased when the BSA concentrations increased and decreased when the pH increased. The amine MTRasym signal of small molecules was very small compared with BSA and was only detectable using short saturation times and higher power levels. The MTRasym(3.5 ppm) between BSA concentration steps and between nearly all pH steps was significantly different for all 3 fitting methods. The Fourier and sSpline methods showed no statistically significant differences; however, the results for the Poly method were significantly higher at some concentrations and pH values. Using only few frequency offsets resulted in less significant differences compared with fitting the complete z-spectrum. In general, MTRasym(3.5 ppm) of gray matter, white matter, and ventricle ROIs from volunteer scans increased with an increase in saturation power and partially decreased with an increase in saturation duration. Intra-ROI covariances of MTRasym(3.5 ppm) revealed the highest variations for Poly, whereas using reduced spectral data resulted in an increased signal variation. CONCLUSIONS Amide proton transfer-CEST imaging is a highly reproducible method in which absolute signal differences of approximately 0.5% are detectable in principle. For in vivo applications, Fourier or sSpline interpolations of z-spectra are preferable. Using reduced data sets delivers similar results but with increased variation and therefore decreased (pH/concentration) differentiation capability. Differentiation capability increases with increases in the saturation duration and power level. The results from the in vitro BSA system cannot be directly transferred to the in vivo situation due to different chemical environments resulting in, for example, higher asymmetric macromolecular cMT effects in vivo. Amine signals from small molecules are unlikely to contribute to APT-CEST at 3 T (except for creatine); however, signals can be enhanced by using short saturation times and higher power levels.
Collapse
|
22
|
Jones KM, Pollard AC, Pagel MD. Clinical applications of chemical exchange saturation transfer (CEST) MRI. J Magn Reson Imaging 2017; 47:11-27. [PMID: 28792646 DOI: 10.1002/jmri.25838] [Citation(s) in RCA: 204] [Impact Index Per Article: 25.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2017] [Accepted: 05/30/2017] [Indexed: 02/06/2023] Open
Abstract
Chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) has been developed and employed in multiple clinical imaging research centers worldwide. Selective radiofrequency (RF) saturation pulses with standard 2D and 3D MRI acquisition schemes are now routinely performed, and CEST MRI can produce semiquantitative results using magnetization transfer ratio asymmetry (MTRasym ) analysis while accounting for B0 inhomogeneity. Faster clinical CEST MRI acquisition methods and more quantitative acquisition and analysis routines are under development. Endogenous biomolecules with amide, amine, and hydroxyl groups have been detected during clinical CEST MRI studies, and exogenous CEST agents have also been administered to patients. These CEST MRI tools show promise for contributing to assessments of cerebral ischemia, neurological disorders, lymphedema, osteoarthritis, muscle physiology, and solid tumors. This review summarizes the salient features of clinical CEST MRI protocols and critically evaluates the utility of CEST MRI for these clinical imaging applications. LEVEL OF EVIDENCE 5 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:11-27.
Collapse
Affiliation(s)
- Kyle M Jones
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona, USA
| | | | - Mark D Pagel
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona, USA.,Department of Chemistry, Rice University, Houston, Texas, USA.,Department of Cancer Systems Imaging, MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
23
|
Cakić N, Tickner B, Zaiss M, Esteban-Gómez D, Platas-Iglesias C, Angelovski G. Spectrally Undiscerned Isomers Might Lead to Erroneous Determination of Water Exchange Rates of paraCEST Eu(III) Agents. Inorg Chem 2017. [DOI: 10.1021/acs.inorgchem.7b00441] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Nevenka Cakić
- MR
Neuroimaging Agents, Max Planck Institute for Biological Cybernetics, 72076 Tübingen, Germany
| | - Ben Tickner
- MR
Neuroimaging Agents, Max Planck Institute for Biological Cybernetics, 72076 Tübingen, Germany
| | - Moritz Zaiss
- High-Field
Magnetic Resonance, Max Planck Institute for Biological Cybernetics, 72076 Tübingen, Germany
| | - David Esteban-Gómez
- Universidade da Coruña, Centro de Investigacións
Científicas Avanzadas (CICA) and Departamento de Química
Fundamental, Facultade de Ciencias, 15071 A Coruña, Galicia, Spain
| | - Carlos Platas-Iglesias
- Universidade da Coruña, Centro de Investigacións
Científicas Avanzadas (CICA) and Departamento de Química
Fundamental, Facultade de Ciencias, 15071 A Coruña, Galicia, Spain
| | - Goran Angelovski
- MR
Neuroimaging Agents, Max Planck Institute for Biological Cybernetics, 72076 Tübingen, Germany
| |
Collapse
|
24
|
Ji Y, Zhou IY, Qiu B, Sun PZ. Progress toward quantitative in vivo chemical exchange saturation transfer (CEST) MRI. Isr J Chem 2017. [DOI: 10.1002/ijch.201700025] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Yang Ji
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital; Harvard Medical School; Rm 2301, 149 13 Street Charlestown MA 02129
- Center for Biomedical Engineering, Department of Electronic Science and Technology; University of Science and Technology of China; Hefei China
| | - Iris Yuwen Zhou
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital; Harvard Medical School; Rm 2301, 149 13 Street Charlestown MA 02129
| | - Bensheng Qiu
- Center for Biomedical Engineering, Department of Electronic Science and Technology; University of Science and Technology of China; Hefei China
| | - Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital; Harvard Medical School; Rm 2301, 149 13 Street Charlestown MA 02129
| |
Collapse
|
25
|
Sun PZ, Xiao G, Zhou IY, Guo Y, Wu R. A method for accurate pH mapping with chemical exchange saturation transfer (CEST) MRI. CONTRAST MEDIA & MOLECULAR IMAGING 2016; 11:195-202. [PMID: 26689424 PMCID: PMC4892969 DOI: 10.1002/cmmi.1680] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2015] [Revised: 10/04/2015] [Accepted: 11/24/2015] [Indexed: 02/05/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI holds enormous promise for imaging pH. Whereas the routine CEST-weighted MRI contrast is complex and susceptible to confounding factors such as labile proton ratio, chemical shift, bulk water relaxation and RF saturation, ratiometric CEST imaging simplifies pH determination. However, the conventional ratiometric CEST (RCEST) MRI approach is limited to CEST agents with multiple exchangeable groups. To address this limitation, RF power-based ratiometric CEST (PRCEST) imaging has been proposed that ratios CEST effects obtained under different RF power levels. Nevertheless, due to concomitant RF saturation (spillover) effect, the recently proposed PRCEST imaging is somewhat dependent on parameters including bulk water relaxation time and chemical shift. Herein we hypothesized that RF power-based ratiometric analysis of RF spillover effect-corrected inverse CEST asymmetry (PRICEST) provides enhanced pH measurement. The postulation was verified numerically, and validated experimentally using an in vitro phantom. Briefly, our study showed that the difference between MRI-determined pH (pHMRI ) and electrode-measured pH being 0.12 ± 0.13 and 0.04 ± 0.03 for PRCEST and PRICEST imaging, respectively, and the newly proposed PRICEST imaging provides significantly more accurate pH determination than PRCEST imaging (P < 0.01, Wilcoxon signed-rank test). Notably, the exchange rate shows dominantly base-catalysed relationship with pH, independent of creatine concentration (P > 0.10, Analysis of Covariance). In addition, the derived labile proton ratio linearly scales with creatine concentration (P < 0.01, Pearson Regression). To summarize, PRICEST MRI provides concentration-independent pH imaging, augmenting prior quantitative CEST methods for accurate pH mapping. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Department of
Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA,
USA
- Corresponding Authors: Prof. Phillip Zhe Sun
(), Athinoula A. Martinos Center
for Biomedical Imaging, Department of Radiology, MGH and Harvard Medical School,
Rm 2301, 149 13 Street, Charlestown, MA 02129, Phone: 617-726-4060,
Fax: 617-726-7422; Prof. Renhua Wu (), Department
of Radiology, 2 Affiliated Hospital of Shantou University Medical
College, Shantou 515041, Guangdong, China, Tel: (86) 0754-88915674
| | - Gang Xiao
- Department of Math and Applied Mathematics, Hanshan Normal
University, Chaozhou, China
- Department of Radiology, 2 Affiliated Hospital of
Shantou University Medical College, Shantou, China
| | - Iris Yuwen Zhou
- Athinoula A. Martinos Center for Biomedical Imaging, Department of
Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA,
USA
| | - Yingkun Guo
- Athinoula A. Martinos Center for Biomedical Imaging, Department of
Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA,
USA
| | - Renhua Wu
- Department of Radiology, 2 Affiliated Hospital of
Shantou University Medical College, Shantou, China
- Corresponding Authors: Prof. Phillip Zhe Sun
(), Athinoula A. Martinos Center
for Biomedical Imaging, Department of Radiology, MGH and Harvard Medical School,
Rm 2301, 149 13 Street, Charlestown, MA 02129, Phone: 617-726-4060,
Fax: 617-726-7422; Prof. Renhua Wu (), Department
of Radiology, 2 Affiliated Hospital of Shantou University Medical
College, Shantou 515041, Guangdong, China, Tel: (86) 0754-88915674
| |
Collapse
|
26
|
Rezaeian MR, Hossein-Zadeh GA, Soltanian-Zadeh H. Simultaneous optimization of power and duration of radio-frequency pulse in PARACEST MRI. Magn Reson Imaging 2016; 34:743-753. [PMID: 26956610 DOI: 10.1016/j.mri.2016.02.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2015] [Revised: 12/29/2015] [Accepted: 02/01/2016] [Indexed: 11/26/2022]
Abstract
Chemical exchange saturation transfer (CEST) MRI is increasingly used to probe mobile proteins and microenvironment properties, and shows great promise for tumor and stroke diagnosis. The CEST effect is complex and depends not only on the CEST agent concentration, exchange rates, the characteristic of the magnetization transfer (MT), and the relaxation properties of the tissue, but also varies with the experimental conditions such as radio-frequency (RF) pulse power and duration. The RF pulse is one of the most important factors that promote the CEST effect for biological properties such as pH, temperature and protein content, especially for contrast agents with intermediate to fast exchange rates. The CEST effect is susceptible to the RF duration and power. The present study aims at determining the optimal power and the corresponding optimal duration (that maximize the CEST effect) using an off-resonance scheme through a new definition of the CEST effect. This definition is formulated by solving the Bloch-McConnell equation through the R1ρ method (based on the eigenspace solution) for both of the MT and CEST effects as well as their interactions. The proposed formulations of the optimal RF pulse power and duration are the first formulations in which the MT effect is considered. The extracted optimal RF pulse duration and power are compared with those of the MTR asymmetry model in two- and three-pool systems, using synthetic data that are similar to the muscle tissue. To validate them further, the formulations are compared with the empirical formulation of the CEST effect and other findings of the previous researches. By extending our formulations, the optimal power and the corresponding optimal duration (in the biological systems with many chemical exchange sites) can be determined.
Collapse
Affiliation(s)
- Mohammad-Reza Rezaeian
- Control and Intelligent Processing Center of Excellence (CIPCE), School of Electrical and Computer Engineering, College of Eng., Univ. of Tehran, Tehran, Iran.
| | - Gholam-Ali Hossein-Zadeh
- Control and Intelligent Processing Center of Excellence (CIPCE), School of Electrical and Computer Engineering, College of Eng., Univ. of Tehran, Tehran, Iran.
| | - Hamid Soltanian-Zadeh
- Control and Intelligent Processing Center of Excellence (CIPCE), School of Electrical and Computer Engineering, College of Eng., Univ. of Tehran, Tehran, Iran; Medical Image Analysis Laboratory, Radiology Department, Henry Ford Hospital, Detroit, MI, USA.
| |
Collapse
|
27
|
Suchý M, Li AX, Milne M, Bartha R, Hudson RHE. DOTMA-based amides (DOTMAMs) as a platform for the development of PARACEST MRI contrast agents. RSC Adv 2016. [DOI: 10.1039/c6ra11741d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
A synthetic methodology leading to previously unknown DOTMA-based secondary amides (DOTMAMs) has been developed.
Collapse
Affiliation(s)
- M. Suchý
- Department of Chemistry
- The University of Western Ontario
- London
- Canada
- Center for Functional and Metabolic Mapping
| | - A. X. Li
- Center for Functional and Metabolic Mapping
- Robarts Research Institute
- The University of Western Ontario
- London
- Canada
| | - M. Milne
- Department of Chemistry
- The University of Western Ontario
- London
- Canada
| | - R. Bartha
- Center for Functional and Metabolic Mapping
- Robarts Research Institute
- The University of Western Ontario
- London
- Canada
| | - R. H. E. Hudson
- Department of Chemistry
- The University of Western Ontario
- London
- Canada
- Centre for Advanced Materials and Biomaterials Research
| |
Collapse
|
28
|
Yoo B, Sheth VR, Howison CM, Douglas MJK, Pineda CT, Maine EA, Baker AF, Pagel MD. Detection of in vivo enzyme activity with CatalyCEST MRI. Magn Reson Med 2015; 71:1221-30. [PMID: 23640714 DOI: 10.1002/mrm.24763] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
PURPOSE CatalyCEST MRI compares the detection of an enzyme-responsive chemical exchange saturation transfer (CEST) agent with the detection of an unresponsive "control" CEST agent that accounts for other conditions that influence CEST. The purpose of this study was to investigate the feasibility of in vivo catalyCEST MRI. METHODS CEST agents that were responsive and unresponsive to the activity of urokinase plasminogen activator were shown to have negligible interaction with each other. A CEST-fast imaging with steady state precession (FISP) MRI protocol was used to acquire MR CEST spectroscopic images with a Capan-2 pancreatic tumor model after intravenous injection of the CEST agents. A function of (super)-Lorentzian line shapes was fit to CEST spectra of a region-of-interest that represented the tumor. RESULTS The CEST effects from each agent showed the same initial uptake into tumor tissues, indicating that both agents had the same pharmacokinetic transport rates. Starting 5 min after injection, CEST from the enzyme-responsive agent disappeared more quickly than CEST from the unresponsive agent, indicating that the enzyme responsive agent was being catalyzed by urokinase plasminogen activator, while both agents also experienced net pharmacokinetic washout from the tumor. CONCLUSION CatalyCEST MRI demonstrates that dynamic tracking of enzyme-responsive and unresponsive CEST agents during the same in vivo MRI study is feasible.
Collapse
Affiliation(s)
- Byunghee Yoo
- MGH/MIT/HMS Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | | | | | | | | | | | | | | |
Collapse
|
29
|
Simultaneous MR imaging for tissue engineering in a rat model of stroke. Sci Rep 2015; 5:14597. [PMID: 26419200 PMCID: PMC4588587 DOI: 10.1038/srep14597] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2015] [Accepted: 09/01/2015] [Indexed: 12/31/2022] Open
Abstract
In situ tissue engineering within a stroke cavity is gradually emerging as a novel therapeutic paradigm. Considering the varied lesion topology within each subject, the placement and distribution of cells within the lesion cavity is challenging. The use of multiple cell types to reconstruct damaged tissue illustrates the complexity of the process, but also highlights the challenges to provide a non-invasive assessment. The distribution of implanted cells within the lesion cavity and crucially the contribution of neural stem cells and endothelial cells to morphogenesis could be visualized simultaneously using two paramagnetic chemical exchange saturation transfer (paraCEST) agents. The development of sophisticated imaging methods is essential to guide delivery of the building blocks for in situ tissue engineering, but will also be essential to understand the dynamics of cellular interactions leading to the formation of de novo tissue.
Collapse
|
30
|
Suchý M, Milne M, Elmehriki AAH, McVicar N, Li AX, Bartha R, Hudson RHE. Introduction of Peripheral Carboxylates to Decrease the Charge on Tm3+ DOTAM-Alkyl Complexes: Implications for Detection Sensitivity and in Vivo Toxicity of PARACEST MRI Contrast Agents. J Med Chem 2015. [DOI: 10.1021/acs.jmedchem.5b00621] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Mojmír Suchý
- Department
of Chemistry, The University of Western Ontario, Chemistry Building, London, Ontario N6A 5B7, Canada
- Department
of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 5K8, Canada
| | - Mark Milne
- Department
of Chemistry, The University of Western Ontario, Chemistry Building, London, Ontario N6A 5B7, Canada
| | - Adam A. H. Elmehriki
- Department
of Chemistry, The University of Western Ontario, Chemistry Building, London, Ontario N6A 5B7, Canada
| | - Nevin McVicar
- Department
of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 5K8, Canada
| | - Alex X. Li
- Department
of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 5K8, Canada
| | - Robert Bartha
- Department
of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 5K8, Canada
| | - Robert H. E. Hudson
- Department
of Chemistry, The University of Western Ontario, Chemistry Building, London, Ontario N6A 5B7, Canada
- Centre
for Advanced Materials and Biomaterials Research, The University of Western Ontario, London, Ontario N6A 5B7, Canada
| |
Collapse
|
31
|
Kunth M, Witte C, Schröder L. Continuous-wave saturation considerations for efficient xenon depolarization. NMR IN BIOMEDICINE 2015; 28:601-606. [PMID: 25900330 DOI: 10.1002/nbm.3307] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Revised: 03/06/2015] [Accepted: 03/18/2015] [Indexed: 06/04/2023]
Abstract
The combination of hyperpolarized Xe with chemical exchange saturation transfer (Hyper-CEST) is a powerful NMR technique to detect highly dilute concentrations of Xe binding sites using RF saturation pulses. Crucially, that combination of saturation pulse strength and duration that generates the maximal Hyper-CEST effect is a priori unknown. In contrast to CEST in proton MRI, where the system reaches a steady-state for long saturation times, Hyper-CEST has an optimal saturation time, i.e. saturating for shorter or longer reduces the Hyper-CEST effect. Here, we derive expressions for this optimal saturation pulse length. We also found that a pulse strength, B1, corresponding to five times the Xe exchange rate, k(BA) (i.e. B1 = 5 k(BA)/γ with the gyromagnetic ratio of (129)Xe, γ), generates directly and without further optimization 96% of the maximal Hyper-CEST contrast while preserving spectral selectivity. As a measure that optimizes the amplitude and the width of the Hyper-CEST response simultaneously, we found an optimal saturation pulse strength corresponding to √2 times the Xe exchange rate, i.e. B1=√2k(BA)/γ. When extremely low host concentration is detected, then the expression for the optimum saturation time simplifies as it approaches the longitudinal relaxation time of free Xe.
Collapse
Affiliation(s)
- Martin Kunth
- ERC Project BiosensorImaging, Leibniz-Institut für Molekulare Pharmakologie (FMP), 13125, Berlin, Germany
| | - Christopher Witte
- ERC Project BiosensorImaging, Leibniz-Institut für Molekulare Pharmakologie (FMP), 13125, Berlin, Germany
| | - Leif Schröder
- ERC Project BiosensorImaging, Leibniz-Institut für Molekulare Pharmakologie (FMP), 13125, Berlin, Germany
| |
Collapse
|
32
|
Xiao G, Sun PZ, Wu R. Fast simulation and optimization of pulse-train chemical exchange saturation transfer (CEST) imaging. Phys Med Biol 2015; 60:4719-30. [PMID: 26020414 DOI: 10.1088/0031-9155/60/12/4719] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Chemical exchange saturation transfer (CEST) MRI has been increasingly applied to detect dilute solutes and physicochemical properties, with promising in vivo applications. Whereas CEST imaging has been implemented with continuous wave (CW) radio-frequency irradiation on preclinical scanners, pulse-train irradiation is often chosen on clinical systems. Therefore, it is necessary to optimize pulse-train CEST imaging, particularly important for translational studies. Because conventional Bloch-McConnell formulas are not in the form of homogeneous differential equations, the routine simulation approach simulates the evolving magnetization step by step, which is time consuming. Herein we developed a computationally efficient numerical solution using matrix iterative analysis of homogeneous Bloch-McConnell equations. The proposed algorithm requires simulation of pulse-train CEST MRI magnetization within one irradiation repeat, with 99% computation time reduction from that of conventional approach under typical experimental conditions. The proposed solution enables determination of labile proton ratio and exchange rate from pulse-train CEST MRI experiment, within 5% from those determined from quantitative CW-CEST MRI. In addition, the structural similarity index analysis shows that the dependence of CEST contrast on saturation pulse flip angle and duration between simulation and experiment was 0.98 ± 0.01, indicating that the proposed simulation algorithm permits fast optimization and quantification of pulse-train CEST MRI.
Collapse
Affiliation(s)
- Gang Xiao
- Department of Mathematics and Statistics, Hanshan Normal University, Guangdong, People's Republic of China
| | | | | |
Collapse
|
33
|
Bar-Shir A, Bulte JWM, Gilad AA. Molecular engineering of nonmetallic biosensors for CEST MRI. ACS Chem Biol 2015; 10:1160-70. [PMID: 25730583 PMCID: PMC11329289 DOI: 10.1021/cb500923v] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Recent advancements in molecular and synthetic biology, combined with synthetic chemistry and biotechnology, have opened up new opportunities to engineer novel platforms that can monitor complex biological processes with various noninvasive imaging modalities. After decades of using gadolinium- or iron-based metallic sensors for MRI, the recently developed chemical exchange saturation transfer (CEST) contrast mechanism has created an opportunity for rational design, in silico, of nonmetallic biosensors for MRI. These biomolecules are either naturally occurring compounds (amino acids, sugars, nucleosides, native proteins) or can be artificially engineered (synthetic probes or recombinant proteins). They can be administered either as exogenous agents or can be genetically (over)expressed. Moreover, they can be precisely engineered to achieve the desired biochemical properties for fine tuning optimized imaging schemes. The availability of these agents marks the dawn of a new scientific era for molecular and cellular MRI.
Collapse
Affiliation(s)
- Amnon Bar-Shir
- †Russell H. Morgan Department of Radiology, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21287, United States
- ‡Cellular Imaging Section and Vascular Biology Program, Institute for Cell Engineering, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
| | - Jeff W M Bulte
- †Russell H. Morgan Department of Radiology, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21287, United States
- ‡Cellular Imaging Section and Vascular Biology Program, Institute for Cell Engineering, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
- §F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland 21205, United States
- ∥Department of Biomedical Engineering, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
- #Department of Oncology, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21287, United States
| | - Assaf A Gilad
- †Russell H. Morgan Department of Radiology, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21287, United States
- ‡Cellular Imaging Section and Vascular Biology Program, Institute for Cell Engineering, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, United States
- §F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland 21205, United States
| |
Collapse
|
34
|
Wu R, Longo DL, Aime S, Sun PZ. Quantitative description of radiofrequency (RF) power-based ratiometric chemical exchange saturation transfer (CEST) pH imaging. NMR IN BIOMEDICINE 2015; 28:555-65. [PMID: 25807919 PMCID: PMC4423622 DOI: 10.1002/nbm.3284] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2014] [Revised: 01/07/2015] [Accepted: 02/10/2015] [Indexed: 02/05/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI holds great promise for the imaging of pH. However, routine CEST measurement varies not only with the pH-dependent chemical exchange rate, but also with CEST agent concentration, providing pH-weighted information. Conventional ratiometric CEST imaging normalizes the confounding concentration factor by analyzing the relative CEST effect from different exchangeable groups, requiring CEST agents with multiple chemically distinguishable labile proton sites. Recently, a radiofrequency (RF) power-based ratiometric CEST MRI approach has been developed for concentration-independent pH MRI using CEST agents with a single exchangeable group. To facilitate quantification and optimization of the new ratiometric analysis, we quantified the RF power-based ratiometric CEST ratio (rCESTR) and derived its signal-to-noise and contrast-to-noise ratios. Using creatine as a representative CEST agent containing a single exchangeable site, our study demonstrated that optimized RF power-based ratiometric analysis provides good pH sensitivity. We showed that rCESTR follows a base-catalyzed exchange relationship with pH independent of creatine concentration. The pH accuracy of RF power-based ratiometric MRI was within 0.15-0.20 pH units. Furthermore, the absolute exchange rate can be obtained from the proposed ratiometric analysis. To summarize, RF power-based ratiometric CEST analysis provides concentration-independent pH-sensitive imaging and complements conventional multiple labile proton group-based ratiometric CEST analysis.
Collapse
Affiliation(s)
- Renhua Wu
- Department of Radiology, 2Affiliated Hospital of Shantou University Medical College, Shantou, China
| | - Dario Livio Longo
- Institute of Biostructure and Bioimaging (CNR) c/o Molecular Biotechnology Center, University of Torino, Torino, Italy
| | - Silvio Aime
- Department of Molecular Biotechnology and Health Sciences, Molecular Imaging Center, University of Torino, Torino, Italy
| | - Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, MGH and Harvard Medical School, Boston, MA, USA
- Corresponding Author: Dr. Phillip Zhe Sun, Ph.D., Biomarker and Metabolism Imaging Lab, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, MGH and Harvard Medical School, Rm 2301, 149 13th Street, Charlestown, MA 02129, Phone: 617-726-4060, Fax: 617-726-7422,
| |
Collapse
|
35
|
Heo HY, Zhang Y, Lee DH, Hong X, Zhou J. Quantitative assessment of amide proton transfer (APT) and nuclear overhauser enhancement (NOE) imaging with extrapolated semi-solid magnetization transfer reference (EMR) signals: Application to a rat glioma model at 4.7 Tesla. Magn Reson Med 2015; 75:137-49. [PMID: 25753614 DOI: 10.1002/mrm.25581] [Citation(s) in RCA: 104] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2014] [Revised: 11/18/2014] [Accepted: 11/21/2014] [Indexed: 12/15/2022]
Abstract
PURPOSE To quantify amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) contributions to in vivo chemical exchange saturation transfer MRI signals in tumors. THEORY AND METHODS Two-pool (free water and semi-solid protons) and four-pool (free water, semi-solid, amide, and upfield NOE-related protons) tissue models combined with the super-Lorentzian lineshape for semi-solid protons were used to fit wide and narrow frequency-offset magnetization-transfer (MT) data, respectively. Extrapolated semi-solid MT signals at 3.5 and -3.5 ppm from water were used as reference signals to quantify APT and NOE, respectively. Six glioma-bearing rats were scanned at 4.7 Tesla. Quantitative APT and NOE signals were compared at three saturation power levels. RESULTS The observed APT signals were significantly higher in the tumor (center and rim) than in the contralateral normal brain tissue at all saturation powers, and were the major contributor to the APT-weighted image contrast (based on MT asymmetry analysis) between the tumor and the normal brain tissue. The NOE (a positive confounding factor) enhanced this APT-weighted image contrast. The fitted amide pool sizes were significantly larger, while the NOE-related pool sizes were significantly smaller in the tumor than in the normal brain tissue. CONCLUSION The extrapolated semi-solid magnetization transfer reference provides a relatively accurate approach for quantitatively measuring pure APT and NOE signals.
Collapse
Affiliation(s)
- Hye-Young Heo
- Divison of MR Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Yi Zhang
- Divison of MR Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Dong-Hoon Lee
- Divison of MR Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Xiaohua Hong
- Divison of MR Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Jinyuan Zhou
- Divison of MR Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| |
Collapse
|
36
|
Wu R, Xiao G, Zhou IY, Ran C, Sun PZ. Quantitative chemical exchange saturation transfer (qCEST) MRI - omega plot analysis of RF-spillover-corrected inverse CEST ratio asymmetry for simultaneous determination of labile proton ratio and exchange rate. NMR IN BIOMEDICINE 2015; 28:376-83. [PMID: 25615718 PMCID: PMC4339459 DOI: 10.1002/nbm.3257] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2014] [Revised: 12/04/2014] [Accepted: 12/16/2014] [Indexed: 02/05/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI is sensitive to labile proton concentration and exchange rate, thus allowing measurement of dilute CEST agent and microenvironmental properties. However, CEST measurement depends not only on the CEST agent properties but also on the experimental conditions. Quantitative CEST (qCEST) analysis has been proposed to address the limitation of the commonly used simplistic CEST-weighted calculation. Recent research has shown that the concomitant direct RF saturation (spillover) effect can be corrected using an inverse CEST ratio calculation. We postulated that a simplified qCEST analysis is feasible with omega plot analysis of the inverse CEST asymmetry calculation. Specifically, simulations showed that the numerically derived labile proton ratio and exchange rate were in good agreement with input values. In addition, the qCEST analysis was confirmed experimentally in a phantom with concurrent variation in CEST agent concentration and pH. Also, we demonstrated that the derived labile proton ratio increased linearly with creatine concentration (P < 0.01) while the pH-dependent exchange rate followed a dominantly base-catalyzed exchange relationship (P < 0.01). In summary, our study verified that a simplified qCEST analysis can simultaneously determine labile proton ratio and exchange rate in a relatively complex in vitro CEST system.
Collapse
Affiliation(s)
- Renhua Wu
- Department of Radiology, 2 Affiliated Hospital of Shantou University Medical College, Shantou, China
| | - Gang Xiao
- Department of Radiology, 2 Affiliated Hospital of Shantou University Medical College, Shantou, China
- Department of Mathematics and Statistics, Hanshan Normal University, Chaozhou, China
| | - Iris Yuwen Zhou
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA
| | - Chongzhao Ran
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA
| | - Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA
- Corresponding Authors: Dr. Phillip Zhe Sun (), Biomarker and Metabolism Imaging Lab, Martinos Center for Biomedical Imaging, MGH and Harvard Medical School, Rm 2301, 149 13 Street, Charlestown, MA 02129, USA, Tel: 617-726-4060, Fax: 617-726-7422
| |
Collapse
|
37
|
Zaiss M, Zu Z, Xu J, Schuenke P, Gochberg DF, Gore JC, Ladd ME, Bachert P. A combined analytical solution for chemical exchange saturation transfer and semi-solid magnetization transfer. NMR IN BIOMEDICINE 2015; 28:217-30. [PMID: 25504828 PMCID: PMC4297271 DOI: 10.1002/nbm.3237] [Citation(s) in RCA: 110] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2014] [Revised: 10/30/2014] [Accepted: 10/31/2014] [Indexed: 05/03/2023]
Abstract
Off-resonant RF irradiation in tissue indirectly lowers the water signal by saturation transfer processes: on the one hand, there are selective chemical exchange saturation transfer (CEST) effects originating from exchanging endogenous protons resonating a few parts per million from water; on the other hand, there is the broad semi-solid magnetization transfer (MT) originating from immobile protons associated with the tissue matrix with kilohertz linewidths. Recently it was shown that endogenous CEST contrasts can be strongly affected by the MT background, so corrections are needed to derive accurate estimates of CEST effects. Herein we show that a full analytical solution of the underlying Bloch-McConnell equations for both MT and CEST provides insights into their interaction and suggests a simple means to isolate their effects. The presented analytical solution, based on the eigenspace solution of the Bloch-McConnell equations, extends previous treatments by allowing arbitrary lineshapes for the semi-solid MT effects and simultaneously describing multiple CEST pools in the presence of a large MT pool for arbitrary irradiation. The structure of the model indicates that semi-solid MT and CEST effects basically add up inversely in determining the steady-state Z-spectrum, as previously shown for direct saturation and CEST effects. Implications for existing previous CEST analyses in the presence of a semi-solid MT are studied and discussed. It turns out that, to accurately quantify CEST contrast, a good reference Z-value, the observed longitudinal relaxation rate of water, and the semi-solid MT pool size fraction must all be known.
Collapse
Affiliation(s)
- Moritz Zaiss
- Deutsches Krebsforschungszentrum (DKFZ), Medical Physics in Radiology, Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- Corresponding author: Moritz Zaiss, Ph. D., German Cancer Research Center (DKFZ), Division of Medical Physics in Radiology, Im Neuenheimer Feld 280, D–69120 Heidelberg, Germany, , Phone: +49 6221–42 2543, FAX: +49 6221–42 3058
| | - Zhongliang Zu
- Vanderbilt University Institute for Imaging Science (VUIIS), Medical Center North, Nashville, Tennessee, USA
| | - Junzhong Xu
- Vanderbilt University Institute for Imaging Science (VUIIS), Medical Center North, Nashville, Tennessee, USA
| | - Patrick Schuenke
- Deutsches Krebsforschungszentrum (DKFZ), Medical Physics in Radiology, Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
| | - Daniel F. Gochberg
- Vanderbilt University Institute for Imaging Science (VUIIS), Medical Center North, Nashville, Tennessee, USA
| | - John C. Gore
- Vanderbilt University Institute for Imaging Science (VUIIS), Medical Center North, Nashville, Tennessee, USA
| | - Mark E. Ladd
- Deutsches Krebsforschungszentrum (DKFZ), Medical Physics in Radiology, Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
| | - Peter Bachert
- Deutsches Krebsforschungszentrum (DKFZ), Medical Physics in Radiology, Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
| |
Collapse
|
38
|
Kim J, Wu Y, Guo Y, Zheng H, Sun PZ. A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging. CONTRAST MEDIA & MOLECULAR IMAGING 2015; 10:163-178. [PMID: 25641791 DOI: 10.1002/cmmi.1628] [Citation(s) in RCA: 89] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2014] [Revised: 08/26/2014] [Accepted: 09/10/2014] [Indexed: 01/10/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI is a versatile imaging method that probes the chemical exchange between bulk water and exchangeable protons. CEST imaging indirectly detects dilute labile protons via bulk water signal changes following selective saturation of exchangeable protons, which offers substantial sensitivity enhancement and has sparked numerous biomedical applications. Over the past decade, CEST imaging techniques have rapidly evolved owing to contributions from multiple domains, including the development of CEST mathematical models, innovative contrast agent designs, sensitive data acquisition schemes, efficient field inhomogeneity correction algorithms, and quantitative CEST (qCEST) analysis. The CEST system that underlies the apparent CEST-weighted effect, however, is complex. The experimentally measurable CEST effect depends not only on parameters such as CEST agent concentration, pH and temperature, but also on relaxation rate, magnetic field strength and more importantly, experimental parameters including repetition time, RF irradiation amplitude and scheme, and image readout. Thorough understanding of the underlying CEST system using qCEST analysis may augment the diagnostic capability of conventional imaging. In this review, we provide a concise explanation of CEST acquisition methods and processing algorithms, including their advantages and limitations, for optimization and quantification of CEST MRI experiments.
Collapse
Affiliation(s)
- Jinsuh Kim
- Department of Radiology, University of Iowa, Iowa City, IA, USA
| | - Yin Wu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Key Laboratory for MRI, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| | - Yingkun Guo
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Key Laboratory for MRI, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| |
Collapse
|
39
|
Cai K, Singh A, Poptani H, Li W, Yang S, Lu Y, Hariharan H, Zhou XJ, Reddy R. CEST signal at 2ppm (CEST@2ppm) from Z-spectral fitting correlates with creatine distribution in brain tumor. NMR IN BIOMEDICINE 2015; 28:1-8. [PMID: 25295758 PMCID: PMC4257884 DOI: 10.1002/nbm.3216] [Citation(s) in RCA: 153] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2014] [Revised: 08/14/2014] [Accepted: 08/17/2014] [Indexed: 05/03/2023]
Abstract
In general, multiple components such as water direct saturation, magnetization transfer (MT), chemical exchange saturation transfer (CEST) and aliphatic nuclear Overhauser effect (NOE) contribute to the Z-spectrum. The conventional CEST quantification method based on asymmetrical analysis may lead to quantification errors due to the semi-solid MT asymmetry and the aliphatic NOE located on a single side of the Z-spectrum. Fitting individual contributors to the Z-spectrum may improve the quantification of each component. In this study, we aim to characterize the multiple exchangeable components from an intracranial tumor model using a simplified Z-spectral fitting method. In this method, the Z-spectrum acquired at low saturation RF amplitude (50 Hz) was modeled as the summation of five Lorentzian functions that correspond to NOE, MT effect, bulk water, amide proton transfer (APT) effect and a CEST peak located at +2 ppm, called CEST@2ppm. With the pixel-wise fitting, the regional variations of these five components in the brain tumor and the normal brain tissue were quantified and summarized. Increased APT effect, decreased NOE and reduced CEST@2ppm were observed in the brain tumor compared with the normal brain tissue. Additionally, CEST@2ppm decreased with tumor progression. CEST@2ppm was found to correlate with the creatine concentration quantified with proton MRS. Based on the correlation curve, the creatine contribution to CEST@2ppm was quantified. The CEST@2ppm signal could be a novel imaging surrogate for in vivo creatine, the important bioenergetics marker. Given its noninvasive nature, this CEST MRI method may have broad applications in cancer bioenergetics.
Collapse
Affiliation(s)
- Kejia Cai
- Department of Radiology, University of Illinois College of Medicine, Chicago, IL, USA
| | - Anup Singh
- Center for Magnetic Resonance and Optical Imaging (CMROI), Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Harish Poptani
- Molecular Imaging Labs, Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Weiguo Li
- Research Resource Center, Department of Bioengineering, University of Illinois College of Medicine, Chicago, IL, USA
- Department of Radiology, Northwestern University, Chicago, IL, USA
| | - Shaolin Yang
- Department of Psychiatry and Radiology, University of Illinois College of Medicine, Chicago, IL, USA
| | - Yang Lu
- Department of Radiology, University of Illinois College of Medicine, Chicago, IL, USA
| | - Hari Hariharan
- Center for Magnetic Resonance and Optical Imaging (CMROI), Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Xiaohong J. Zhou
- Department of Radiology, University of Illinois College of Medicine, Chicago, IL, USA
| | - Ravinder Reddy
- Center for Magnetic Resonance and Optical Imaging (CMROI), Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
40
|
Song X, Xu J, Xia S, Yadav NN, Lal B, Laterra J, Bulte JWM, van Zijl PCM, McMahon MT. Multi-echo length and offset VARied saturation (MeLOVARS) method for improved CEST imaging. Magn Reson Med 2014; 73:488-96. [PMID: 25516490 DOI: 10.1002/mrm.25567] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2014] [Revised: 11/14/2014] [Accepted: 11/14/2014] [Indexed: 12/15/2022]
Abstract
PURPOSE The aim of this study was to develop a technique for rapid collection of chemical exchange saturation transfer images with the saturation varied to modulate signal loss transfer and enhance contrast. METHODS Multi-echo Length and Offset VARied Saturation (MeLOVARS) divides the saturation pulse of length Tsat into N = 3-8 submodules, each consisting of a saturation pulse with length of Tsat /N (∼0.3-1 s), one or more low flip-angle gradient-echo readout(s) and a flip back pulse. This results in N readouts with increasing saturation time from Tsat /N to Tsat without extra scan time. RESULTS For phantoms, eight images with Tsat incremented every 0.5 s from 0.5-4 s were collected simultaneously using MeLOVARS, which allows rapid determination of exchange rates for agent protons. For live mice bearing glioblastomas, the Z-spectra for five different Tsat values from 0.5 to 2.5 s were acquired in a time normally used for one Tsat . With the additional Tsat -dependence information, LOVARS phase maps were produced with a more clearly defined tumor boundary and an estimated 4.3-fold enhanced contrast-to-noise ratio (CNR). We also show that enhancing CNR is achievable by simply averaging the collected images or transforming them using the principal component analysis. CONCLUSIONS MeLOVARS enables collection of multiple saturation-time-weighted images without extra time, producing a LOVARS phase map with increased CNR.
Collapse
Affiliation(s)
- Xiaolei Song
- Division of MR Research, The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, Maryland, USA; F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Sun PZ, Wang Y, Dai Z, Xiao G, Wu R. Quantitative chemical exchange saturation transfer (qCEST) MRI--RF spillover effect-corrected omega plot for simultaneous determination of labile proton fraction ratio and exchange rate. CONTRAST MEDIA & MOLECULAR IMAGING 2014; 9:268-75. [PMID: 24706610 DOI: 10.1002/cmmi.1569] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2013] [Revised: 07/28/2013] [Accepted: 08/11/2013] [Indexed: 12/20/2022]
Abstract
Chemical exchange saturation transfer (CEST) MRI is sensitive to dilute proteins and peptides as well as microenvironmental properties. However, the complexity of the CEST MRI effect, which varies with the labile proton content, exchange rate and experimental conditions, underscores the need for developing quantitative CEST (qCEST) analysis. Towards this goal, it has been shown that omega plot is capable of quantifying paramagnetic CEST MRI. However, the use of the omega plot is somewhat limited for diamagnetic CEST (DIACEST) MRI because it is more susceptible to direct radio frequency (RF) saturation (spillover) owing to the relatively small chemical shift. Recently, it has been found that, for dilute DIACEST agents that undergo slow to intermediate chemical exchange, the spillover effect varies little with the labile proton ratio and exchange rate. Therefore, we postulated that the omega plot analysis can be improved if RF spillover effect could be estimated and taken into account. Specifically, simulation showed that both labile proton ratio and exchange rate derived using the spillover effect-corrected omega plot were in good agreement with simulated values. In addition, the modified omega plot was confirmed experimentally, and we showed that the derived labile proton ratio increased linearly with creatine concentration (p < 0.01), with little difference in their exchange rate (p = 0.32). In summary, our study extends the conventional omega plot for quantitative analysis of DIACEST MRI.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, 02129, USA
| | | | | | | | | |
Collapse
|
42
|
Kunth M, Witte C, Schröder L. Quantitative chemical exchange saturation transfer with hyperpolarized nuclei (qHyper-CEST): Sensing xenon-host exchange dynamics and binding affinities by NMR. J Chem Phys 2014; 141:194202. [DOI: 10.1063/1.4901429] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Affiliation(s)
- M. Kunth
- ERC Project BiosensorImaging, Leibniz-Institut für Molekulare Pharmakologie (FMP), 13125 Berlin, Germany
| | - C. Witte
- ERC Project BiosensorImaging, Leibniz-Institut für Molekulare Pharmakologie (FMP), 13125 Berlin, Germany
| | - L. Schröder
- ERC Project BiosensorImaging, Leibniz-Institut für Molekulare Pharmakologie (FMP), 13125 Berlin, Germany
| |
Collapse
|
43
|
Jin T, Kim SG. Advantages of chemical exchange-sensitive spin-lock (CESL) over chemical exchange saturation transfer (CEST) for hydroxyl- and amine-water proton exchange studies. NMR IN BIOMEDICINE 2014; 27:1313-24. [PMID: 25199631 PMCID: PMC4201909 DOI: 10.1002/nbm.3191] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2014] [Revised: 07/16/2014] [Accepted: 07/24/2014] [Indexed: 05/03/2023]
Abstract
The chemical exchange (CE) rate of endogenous hydroxyl and amine protons with water is often comparable to the difference in their chemical shifts. These intermediate exchange processes have been imaged by the CE saturation transfer (CEST) approach with low-power and long-duration irradiation. However, the sensitivity is not optimal and, more importantly, the signal is contaminated by slow magnetization transfer processes. Here, the properties of CEST signals are compared with those of a CE-sensitive spin-lock (CESL) technique irradiating at the labile proton frequency. First, using a higher power and shorter irradiation in CE-MRI, we obtain: (i) an increased selectivity to faster CE rates via a higher sensitivity to faster CEs and a lower sensitivity to slower CEs and magnetization transfer processes; and (ii) a decreased in vivo asymmetric magnetization transfer contrast measured at ±15 ppm. The sensitivity gain of CESL over CEST is higher for a higher power and shorter irradiation. Unlike CESL, CEST signals oscillate at a very high power and short irradiation. Second, time-dependent CEST and CESL signals are well modeled by analytical solutions of CE-MRI with an asymmetric population approximation, which can be used for quantitative CE-MRI and validated by simulations of Bloch-McConnell equations and phantom experiments. Finally, the in vivo amine-water proton exchange contrast measured at 2.5 ppm with ω1 = 500 Hz is 18% higher in sensitivity for CESL than CEST at 9.4 T. Overall, CESL provides better exchange rate selectivity and sensitivity than CEST; therefore, CESL is more suitable for CE-MRI of intermediate exchange protons.
Collapse
Affiliation(s)
- Tao Jin
- Neuroimaging Laboratory, Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Seong-Gi Kim
- Neuroimaging Laboratory, Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
- Center for Neuroscience Imaging Research, Institute for Basic Science (IBS), Suwon, Korea
- Departments of Global Biomedical Engineering and Biological Sciences, Sungkyunkwan University, Suwon, Korea
| |
Collapse
|
44
|
Tee YK, Harston GWJ, Blockley N, Okell TW, Levman J, Sheerin F, Cellerini M, Jezzard P, Kennedy J, Payne SJ, Chappell MA. Comparing different analysis methods for quantifying the MRI amide proton transfer (APT) effect in hyperacute stroke patients. NMR IN BIOMEDICINE 2014; 27:1019-1029. [PMID: 24913989 PMCID: PMC4737232 DOI: 10.1002/nbm.3147] [Citation(s) in RCA: 81] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2013] [Revised: 05/06/2014] [Accepted: 05/07/2014] [Indexed: 05/08/2023]
Abstract
Amide proton transfer (APT) imaging is a pH mapping method based on the chemical exchange saturation transfer phenomenon that has potential for penumbra identification following stroke. The majority of the literature thus far has focused on generating pH-weighted contrast using magnetization transfer ratio asymmetry analysis instead of quantitative pH mapping. In this study, the widely used asymmetry analysis and a model-based analysis were both assessed on APT data collected from healthy subjects (n = 2) and hyperacute stroke patients (n = 6, median imaging time after onset = 2 hours 59 minutes). It was found that the model-based approach was able to quantify the APT effect with the lowest variation in grey and white matter (≤ 13.8 %) and the smallest average contrast between these two tissue types (3.48 %) in the healthy volunteers. The model-based approach also performed quantitatively better than the other measures in the hyperacute stroke patient APT data, where the quantified APT effect in the infarct core was consistently lower than in the contralateral normal appearing tissue for all the patients recruited, with the group average of the quantified APT effect being 1.5 ± 0.3 % (infarct core) and 1.9 ± 0.4 % (contralateral). Based on the fitted parameters from the model-based analysis and a previously published pH and amide proton exchange rate relationship, quantitative pH maps for hyperacute stroke patients were generated, for the first time, using APT imaging.
Collapse
Affiliation(s)
- Y. K. Tee
- Institute of Biomedical Engineering, Department of Engineering ScienceUniversity of OxfordOxfordUK
- Centre for Doctoral Training in Healthcare InnovationUniversity of OxfordOxfordUK
| | | | - N. Blockley
- Oxford Centre of Functional MRI of the Brain, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUK
| | - Thomas W. Okell
- Oxford Centre of Functional MRI of the Brain, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUK
| | - J. Levman
- Institute of Biomedical Engineering, Department of Engineering ScienceUniversity of OxfordOxfordUK
| | - F. Sheerin
- Department of NeuroradiologyOxford University Hospitals NHS TrustOxfordUK
| | - M. Cellerini
- Department of NeuroradiologyOxford University Hospitals NHS TrustOxfordUK
| | - P. Jezzard
- Oxford Centre of Functional MRI of the Brain, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUK
| | - J. Kennedy
- Acute Stroke ProgrammeRadcliffe Department of MedicineOxfordUK
| | - S. J. Payne
- Institute of Biomedical Engineering, Department of Engineering ScienceUniversity of OxfordOxfordUK
| | - M. A. Chappell
- Institute of Biomedical Engineering, Department of Engineering ScienceUniversity of OxfordOxfordUK
| |
Collapse
|
45
|
Sun PZ, Longo DL, Hu W, Xiao G, Wu R. Quantification of iopamidol multi-site chemical exchange properties for ratiometric chemical exchange saturation transfer (CEST) imaging of pH. Phys Med Biol 2014; 59:4493-504. [PMID: 25054859 DOI: 10.1088/0031-9155/59/16/4493] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
pH-sensitive chemical exchange saturation transfer (CEST) MRI holds great promise for in vivo applications. However, the CEST effect depends on not only exchange rate and hence pH, but also on the contrast agent concentration, which must be determined independently for pH quantification. Ratiometric CEST MRI normalizes the concentration effect by comparing CEST measurements of multiple labile protons to simplify pH determination. Iopamidol, a commonly used x-ray contrast agent, has been explored as a ratiometric CEST agent for imaging pH. However, iopamidol CEST properties have not been solved, determination of which is important for optimization and quantification of iopamidol pH imaging. Our study numerically solved iopamidol multi-site pH-dependent chemical exchange properties. We found that iopamidol CEST MRI is suitable for measuring pH between 6 and 7.5 despite that T1 and T2 measurements varied substantially with pH and concentration. The pH MRI precision decreased with pH and concentration. The standard deviation of pH determined from MRI was 0.2 and 0.4 pH unit for 40 and 20 mM iopamidol solution of pH 6, and it improved to be less than 0.1 unit for pH above 7. Moreover, we determined base-catalyzed chemical exchange for 2-hydrooxypropanamido (ksw = 1.2*10(pH-4.1)) and amide (ksw = 1.2*10(pH-4.6)) protons that are statistically different from each other (P < 0.01, ANCOVA), understanding of which should help guide in vivo translation of iopamidol pH imaging.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Department of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| | | | | | | | | |
Collapse
|
46
|
McVicar N, Li AX, Gonçalves DF, Bellyou M, Meakin SO, Prado MAM, Bartha R. Quantitative tissue pH measurement during cerebral ischemia using amine and amide concentration-independent detection (AACID) with MRI. J Cereb Blood Flow Metab 2014; 34:690-8. [PMID: 24496171 PMCID: PMC3982091 DOI: 10.1038/jcbfm.2014.12] [Citation(s) in RCA: 127] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2013] [Revised: 11/26/2013] [Accepted: 12/23/2013] [Indexed: 11/09/2022]
Abstract
Tissue pH is an indicator of altered cellular metabolism in diseases including stroke and cancer. Ischemic tissue often becomes acidic due to increased anaerobic respiration leading to irreversible cellular damage. Chemical exchange saturation transfer (CEST) effects can be used to generate pH-weighted magnetic resonance imaging (MRI) contrast, which has been used to delineate the ischemic penumbra after ischemic stroke. In the current study, a novel MRI ratiometric technique is presented to measure absolute pH using the ratio of CEST-mediated contrast from amine and amide protons: amine/amide concentration-independent detection (AACID). Effects of CEST were observed at 2.75 parts per million (p.p.m.) for amine protons and at 3.50 p.p.m. for amide protons downfield (i.e., higher frequency) from bulk water. Using numerical simulations and in vitro MRI experiments, we showed that pH measured using AACID was independent of tissue relaxation time constants, macromolecular magnetization transfer effects, protein concentration, and temperature within the physiologic range. After in vivo pH calibration using phosphorus ((31)P) magnetic resonance spectroscopy ((31)P-MRS), local acidosis is detected in mouse brain after focal permanent middle cerebral artery occlusion. In summary, our results suggest that AACID represents a noninvasive method to directly measure the spatial distribution of absolute pH in vivo using CEST MRI.
Collapse
Affiliation(s)
- Nevin McVicar
- Department of Medical Biophysics, University of Western Ontario, London, Ontario, Canada
| | - Alex X Li
- Robarts Research Institute, University of Western Ontario, London, Ontario, Canada
| | - Daniela F Gonçalves
- Robarts Research Institute, University of Western Ontario, London, Ontario, Canada
- Department of Physiology and Biophysics, Neuroscience Centre, Federal University of Minas Gerais, Belo Horizonte, Brazil
| | - Miranda Bellyou
- Robarts Research Institute, University of Western Ontario, London, Ontario, Canada
| | - Susan O Meakin
- Robarts Research Institute, University of Western Ontario, London, Ontario, Canada
- Department of Biochemistry, University of Western Ontario, Western University, London, Ontario, Canada
| | - Marco AM Prado
- Robarts Research Institute, University of Western Ontario, London, Ontario, Canada
- Department of Physiology and Pharmacology, University of Western Ontario, London, Ontario, Canada
- Department of Anatomy and Cell Biology, University of Western Ontario, London, Ontario, Canada
| | - Robert Bartha
- Department of Medical Biophysics, University of Western Ontario, London, Ontario, Canada
- Robarts Research Institute, University of Western Ontario, London, Ontario, Canada
| |
Collapse
|
47
|
Zaiss M, Bachert P. Chemical exchange saturation transfer (CEST) and MRZ-spectroscopyin vivo: a review of theoretical approaches and methods. Phys Med Biol 2013; 58:R221-69. [DOI: 10.1088/0031-9155/58/22/r221] [Citation(s) in RCA: 216] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
48
|
Sun PZ, Wang Y, Xiao G, Wu R. Simultaneous experimental determination of labile proton fraction ratio and exchange rate with irradiation radio frequency power-dependent quantitative CEST MRI analysis. CONTRAST MEDIA & MOLECULAR IMAGING 2013; 8:246-51. [PMID: 23606428 DOI: 10.1002/cmmi.1524] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2012] [Revised: 11/22/2012] [Accepted: 11/26/2012] [Indexed: 12/20/2022]
Abstract
Chemical exchange saturation transfer (CEST) imaging is sensitive to dilute proteins/peptides and microenvironmental properties, and has been increasingly evaluated for molecular imaging and in vivo applications. However, the experimentally measured CEST effect depends on the CEST agent concentration, exchange rate and relaxation time. In addition, there may be non-negligible direct radio-frequency (RF) saturation effects, particularly severe for diamagnetic CEST (DIACEST) agents owing to their relatively small chemical shift difference from that of the bulk water resonance. As such, the commonly used asymmetry analysis only provides CEST-weighted information. Recently, it has been shown with numerical simulation that both labile proton concentration and exchange rate can be determined by evaluating the RF power dependence of DIACEST effect. To validate the simulation results, we prepared and imaged two CEST phantoms: a pH phantom of serially titrated pH at a fixed creatine concentration and a concentration phantom of serially varied creatine concentration titrated to the same pH, and solved the labile proton fraction ratio and exchange rate per-pixel. For the concentration phantom, we showed that the labile proton fraction ratio is proportional to the CEST agent concentration with negligible change in the exchange rate. Additionally, we found the exchange rate of the pH phantom is dominantly base-catalyzed with little difference in the labile proton fraction ratio. In summary, our study demonstrated quantitative DIACEST MRI, which remains promising to augment the conventional CEST-weighted MRI analysis.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Athinoula A Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA
| | | | | | | |
Collapse
|
49
|
Stevens TK, Milne M, Elmehriki AAH, Suchý M, Bartha R, Hudson RHE. A DOTAM-based paraCEST agent favoring TSAP geometry for enhanced amide proton chemical shift dispersion and temperature sensitivity. CONTRAST MEDIA & MOLECULAR IMAGING 2013; 8:289-92. [PMID: 23606433 DOI: 10.1002/cmmi.1527] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2012] [Revised: 11/06/2012] [Accepted: 12/11/2012] [Indexed: 11/09/2022]
Abstract
The Tm(3+) chelate of DOTAM [1,4,7,10-tetrakis(carbamoylmethyl)-1,4,7,10-tetraazacyclododecane] possessing sterically demanding t-butyl amide substitution favors TSAP geometry. This chelate displayed a paraCEST signal associated with the highly shifted amide proton signal at approximately -100 ppm that was beyond the frequency of macromolecule magnetization transfer. This signal also displayed high temperature dependence (0.57 ppm °C(-1)) in the range of 35-42 °C and at neutral pH.
Collapse
Affiliation(s)
- Todd K Stevens
- Centre for Functional and Metabolic Mapping, Robarts Research Institute, London, Ontario, Canada
| | | | | | | | | | | |
Collapse
|
50
|
Tee YK, Khrapitchev AA, Sibson NR, Payne SJ, Chappell MA. Optimal sampling schedule for chemical exchange saturation transfer. Magn Reson Med 2013; 70:1251-1262. [PMID: 23315799 DOI: 10.1002/mrm.24567] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2012] [Revised: 10/02/2012] [Accepted: 10/29/2012] [Indexed: 12/27/2022]
Abstract
The sampling schedule for chemical exchange saturation transfer imaging is normally uniformly distributed across the saturation frequency offsets. When this kind of evenly distributed sampling schedule is used to quantify the chemical exchange saturation transfer effect using model-based analysis, some of the collected data are minimally informative to the parameters of interest. For example, changes in labile proton exchange rate and concentration mainly affect the magnetization near the resonance frequency of the labile pool. In this study, an optimal sampling schedule was designed for a more accurate quantification of amine proton exchange rate and concentration, and water center frequency shift based on an algorithm previously applied to magnetization transfer and arterial spin labeling. The resulting optimal sampling schedule samples repeatedly around the resonance frequency of the amine pool and also near to the water resonance to maximize the information present within the data for quantitative model-based analysis. Simulation and experimental results on tissue-like phantoms showed that greater accuracy and precision (>30% and >46%, respectively, for some cases) were achieved in the parameters of interest when using optimal sampling schedule compared with evenly distributed sampling schedule. Hence, the proposed optimal sampling schedule could replace evenly distributed sampling schedule in chemical exchange saturation transfer imaging to improve the quantification of the chemical exchange saturation transfer effect and parameter estimation.
Collapse
Affiliation(s)
- Y K Tee
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, UK; Department of Engineering Science, Institute of Biomedical Engineering, Centre for Doctoral Training in Healthcare Innovation, University of Oxford, UK
| | | | | | | | | |
Collapse
|