1
|
Lee NG, Javed A, Jao TR, Nayak KS. Numerical approximation to the general kinetic model for ASL quantification. Magn Reson Med 2020; 84:2846-2857. [PMID: 32367574 DOI: 10.1002/mrm.28304] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Revised: 03/19/2020] [Accepted: 04/08/2020] [Indexed: 12/21/2022]
Abstract
PURPOSE To develop a numerical approximation to the general kinetic model for arterial spin labeling (ASL) quantification that will enable greater flexibility in ASL acquisition methods. THEORY The Bloch-McConnell equations are extended to include the effects of single-compartment inflow and outflow on both the transverse and longitudinal magnetization. These can be solved using an extension of Jaynes' matrix formalism with piecewise constant approximation of incoming labeled arterial flow and a clearance operator for outgoing venous flow. METHODS The proposed numerical approximation is compared with the general kinetic model using simulations of pulsed labeling and pseudo-continuous labeling and a broad range of transit time and bolus duration for tissue blood flow of 0.6 mL/g/min. Accuracy of the approximation is studied as a function of the timestep using Monte-Carlo simulations. Three additional scenarios are demonstrated: (1) steady-pulsed ASL, (2) MR fingerprinting ASL, and (3) balanced SSFP and spoiled gradient-echo sequences. RESULTS The proposed approximation was found to be arbitrarily accurate for pulsed labeling and pseudo-continuous labeling. The pulsed labeling/pseudo-continuous labeling approximation error compared with the general kinetic model was less than 0.002% (<0.002%) and less than 0.05% (<0.05%) for timesteps of 3 ms and 35 ms, respectively. The proposed approximation matched well with customized signal expressions of steady-pulsed ASL and MR fingerprinting ASL. The simulations of simultaneous modeling of flow, T2 , and magnetization transfer showed an increase in steady-state balanced SSFP and spoiled gradient signals. CONCLUSION We demonstrate a numerical approximation of the "Bloch-McConnell flow" equations that enables arbitrarily accurate modeling of pulsed ASL and pseudo-continuous labeling signals comparable to the general kinetic model. This enables increased flexibility in the experiment design for quantitative ASL.
Collapse
Affiliation(s)
- Nam G Lee
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, USA
| | - Ahsan Javed
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA
| | - Terrence R Jao
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, USA
| | - Krishna S Nayak
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA
| |
Collapse
|
2
|
Lahiri A, Fessler JA, Hernandez‐Garcia L. Optimizing MRF‐ASL scan design for precise quantification of brain hemodynamics using neural network regression. Magn Reson Med 2019; 83:1979-1991. [DOI: 10.1002/mrm.28051] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Revised: 09/13/2019] [Accepted: 10/05/2019] [Indexed: 01/02/2023]
Affiliation(s)
- Anish Lahiri
- Department of Electrical and Computer Engineering University of Michigan Ann Arbor Michigan USA
| | - Jeffrey A. Fessler
- Department of Electrical and Computer Engineering University of Michigan Ann Arbor Michigan USA
| | | |
Collapse
|
3
|
Hernandez-Garcia L, Lahiri A, Schollenberger J. Recent progress in ASL. Neuroimage 2019; 187:3-16. [PMID: 29305164 PMCID: PMC6030511 DOI: 10.1016/j.neuroimage.2017.12.095] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2017] [Revised: 12/21/2017] [Accepted: 12/30/2017] [Indexed: 11/26/2022] Open
Abstract
This article aims to provide the reader with an overview of recent developments in Arterial Spin Labeling (ASL) MRI techniques. A great deal of progress has been made in recent years in terms of the SNR and acquisition speed. New strategies have been introduced to improve labeling efficiency, reduce artefacts, and estimate other relevant physiological parameters besides perfusion. As a result, ASL techniques has become a reliable workhorse for researchers as well as clinicians. After a brief overview of the technique's fundamentals, this article will review new trends and variants in ASL including vascular territory mapping and velocity selective ASL, as well as arterial blood volume imaging techniques. This article will also review recent processing techniques to reduce partial volume effects and physiological noise. Next the article will examine how ASL techniques can be leveraged to calculate additional physiological parameters beyond perfusion and finally, it will review a few recent applications of ASL in the literature.
Collapse
Affiliation(s)
| | - Anish Lahiri
- FMRI Laboratory, University of Michigan, United States
| | | |
Collapse
|
4
|
Yoon AJ, Do HP, Cen S, Fong MW, Saremi F, Barr ML, Nayak KS. Assessment of segmental myocardial blood flow and myocardial perfusion reserve by adenosine-stress myocardial arterial spin labeling perfusion imaging. J Magn Reson Imaging 2017; 46:413-420. [DOI: 10.1002/jmri.25604] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2016] [Accepted: 12/05/2016] [Indexed: 01/19/2023] Open
Affiliation(s)
- Andrew J. Yoon
- Department of Medicine, Division of Cardiology, Keck School of Medicine of USC; University of Southern California; Los Angeles California USA
| | - Hung Phi Do
- Department of Physics and Astronomy; University of Southern California; Los Angeles California USA
| | - Steven Cen
- Department of Radiology, Keck School of Medicine of USC; University of Southern California; Los Angeles California USA
| | - Michael W. Fong
- Department of Medicine, Division of Cardiology, Keck School of Medicine of USC; University of Southern California; Los Angeles California USA
| | - Farhood Saremi
- Department of Radiology, Keck School of Medicine of USC; University of Southern California; Los Angeles California USA
| | - Mark L. Barr
- Department of Cardiothoracic Surgery, Keck School of Medicine of USC; University of Southern California; Los Angeles California USA
| | - Krishna S. Nayak
- Ming Hsieh Department of Electrical Engineering; University of Southern California; Los Angeles California USA
| |
Collapse
|
5
|
Kober F, Jao T, Troalen T, Nayak KS. Myocardial arterial spin labeling. J Cardiovasc Magn Reson 2016; 18:22. [PMID: 27071861 PMCID: PMC4830031 DOI: 10.1186/s12968-016-0235-4] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2015] [Accepted: 03/22/2016] [Indexed: 11/10/2022] Open
Abstract
Arterial spin labeling (ASL) is a cardiovascular magnetic resonance (CMR) technique for mapping regional myocardial blood flow. It does not require any contrast agents, is compatible with stress testing, and can be performed repeatedly or even continuously. ASL-CMR has been performed with great success in small-animals, but sensitivity to date has been poor in large animals and humans and remains an active area of research. This review paper summarizes the development of ASL-CMR techniques, current state-of-the-art imaging methods, the latest findings from pre-clinical and clinical studies, and future directions. We also explain how successful developments in brain ASL and small-animal ASL-CMR have helped to inform developments in large animal and human ASL-CMR.
Collapse
Affiliation(s)
- Frank Kober
- />Aix-Marseille Université, CNRS CRMBM UMR 7339, Centre de Résonance Magnétique Biologique et Médicale, Marseille, France
| | - Terrence Jao
- />Department of Biomedical Engineering, University of Southern California, Los Angeles, California USA
| | - Thomas Troalen
- />Aix-Marseille Université, CNRS CRMBM UMR 7339, Centre de Résonance Magnétique Biologique et Médicale, Marseille, France
| | - Krishna S. Nayak
- />Department of Biomedical Engineering, University of Southern California, Los Angeles, California USA
- />Ming Hsieh Department of Electrical Engineering, University of Southern California, Los Angeles, California USA
| |
Collapse
|
6
|
Abdesselam I, Pepino P, Troalen T, Macia M, Ancel P, Masi B, Fourny N, Gaborit B, Giannesini B, Kober F, Dutour A, Bernard M. Time course of cardiometabolic alterations in a high fat high sucrose diet mice model and improvement after GLP-1 analog treatment using multimodal cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2015; 17:95. [PMID: 26546347 PMCID: PMC4636800 DOI: 10.1186/s12968-015-0198-x] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2015] [Accepted: 10/28/2015] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND Cardiovascular complications of obesity and diabetes are major health problems. Assessing their development, their link with ectopic fat deposition and their flexibility with therapeutic intervention is essential. The aim of this study was to longitudinally investigate cardiac alterations and ectopic fat accumulation associated with diet-induced obesity using multimodal cardiovascular magnetic resonance (CMR) in mice. The second objective was to monitor cardiac response to exendin-4 (GLP-1 receptor agonist). METHODS Male C57BL6R mice subjected to a high fat (35 %) high sucrose (34 %) (HFHSD) or a standard diet (SD) during 4 months were explored every month with multimodal CMR to determine hepatic and myocardial triglyceride content (HTGC, MTGC) using proton MR spectroscopy, cardiac function with cine cardiac MR (CMR) and myocardial perfusion with arterial spin labeling CMR. Furthermore, mice treated with exendin-4 (30 μg/kg SC BID) after 4 months of diet were explored before and 14 days post-treatment with multimodal CMR. RESULTS HFHSD mice became significantly heavier (+33 %) and displayed glucose homeostasis impairment (1-month) as compared to SD mice, and developed early increase in HTGC (1 month, +59 %) and MTGC (2-month, +63 %). After 3 months, HFHSD mice developed cardiac dysfunction with significantly higher diastolic septum wall thickness (sWtnD) (1.28 ± 0.03 mm vs. 1.12 ± 0.03 mm) and lower cardiac index (0.45 ± 0.06 mL/min/g vs. 0.68 ± 0.07 mL/min/g, p = 0.02) compared to SD mice. A significantly lower cardiac perfusion was also observed (4 months:7.5 ± 0.8 mL/g/min vs. 10.0 ± 0.7 mL/g/min, p = 0.03). Cardiac function at 4 months was negatively correlated to both HTGC and MTGC (p < 0.05). 14-day treatment with Exendin-4 (Ex-4) dramatically reversed all these alterations in comparison with placebo-treated HFHSD. Ex-4 diminished myocardial triglyceride content (-57.8 ± 4.1 %), improved cardiac index (+38.9 ± 10.9 %) and restored myocardial perfusion (+52.8 ± 16.4 %) under isoflurane anesthesia. Interestingly, increased wall thickness and hepatic steatosis reductions were independent of weight loss and glycemia decrease in multivariate analysis (p < 0.05). CONCLUSION CMR longitudinal follow-up of cardiac consequences of obesity and diabetes showed early accumulation of ectopic fat in mice before the occurrence of microvascular and contractile dysfunction. This study also supports a cardioprotective effect of glucagon-like peptide-1 receptor agonist.
Collapse
Affiliation(s)
- Inès Abdesselam
- Aix-Marseille Université, CNRS, CRMBM, UMR7339, 27, Bd Jean Moulin, 13385, Marseille, France
- Aix-Marseille Université, NORT, Inserm U1062/Inra1260, 13385, Marseille, France
| | - Pauline Pepino
- Aix-Marseille Université, CNRS, CRMBM, UMR7339, 27, Bd Jean Moulin, 13385, Marseille, France
| | - Thomas Troalen
- Aix-Marseille Université, CNRS, CRMBM, UMR7339, 27, Bd Jean Moulin, 13385, Marseille, France
| | - Michael Macia
- Aix-Marseille Université, CNRS, CRMBM, UMR7339, 27, Bd Jean Moulin, 13385, Marseille, France
| | - Patricia Ancel
- Aix-Marseille Université, NORT, Inserm U1062/Inra1260, 13385, Marseille, France
| | - Brice Masi
- Aix-Marseille Université, CNRS, CRMBM, UMR7339, 27, Bd Jean Moulin, 13385, Marseille, France
| | - Natacha Fourny
- Aix-Marseille Université, CNRS, CRMBM, UMR7339, 27, Bd Jean Moulin, 13385, Marseille, France
| | - Bénédicte Gaborit
- Aix-Marseille Université, NORT, Inserm U1062/Inra1260, 13385, Marseille, France
- Endocrinology, Metabolic diseases and nutrition, CHU Nord, Marseille, France
| | - Benoît Giannesini
- Aix-Marseille Université, CNRS, CRMBM, UMR7339, 27, Bd Jean Moulin, 13385, Marseille, France
| | - Frank Kober
- Aix-Marseille Université, CNRS, CRMBM, UMR7339, 27, Bd Jean Moulin, 13385, Marseille, France
| | - Anne Dutour
- Aix-Marseille Université, NORT, Inserm U1062/Inra1260, 13385, Marseille, France
- Endocrinology, Metabolic diseases and nutrition, CHU Nord, Marseille, France
| | - Monique Bernard
- Aix-Marseille Université, CNRS, CRMBM, UMR7339, 27, Bd Jean Moulin, 13385, Marseille, France.
| |
Collapse
|
7
|
Bakermans AJ, Abdurrachim D, Moonen RPM, Motaal AG, Prompers JJ, Strijkers GJ, Vandoorne K, Nicolay K. Small animal cardiovascular MR imaging and spectroscopy. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2015; 88-89:1-47. [PMID: 26282195 DOI: 10.1016/j.pnmrs.2015.03.001] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Revised: 03/09/2015] [Accepted: 03/09/2015] [Indexed: 06/04/2023]
Abstract
The use of MR imaging and spectroscopy for studying cardiovascular disease processes in small animals has increased tremendously over the past decade. This is the result of the remarkable advances in MR technologies and the increased availability of genetically modified mice. MR techniques provide a window on the entire timeline of cardiovascular disease development, ranging from subtle early changes in myocardial metabolism that often mark disease onset to severe myocardial dysfunction associated with end-stage heart failure. MR imaging and spectroscopy techniques play an important role in basic cardiovascular research and in cardiovascular disease diagnosis and therapy follow-up. This is due to the broad range of functional, structural and metabolic parameters that can be quantified by MR under in vivo conditions non-invasively. This review describes the spectrum of MR techniques that are employed in small animal cardiovascular disease research and how the technological challenges resulting from the small dimensions of heart and blood vessels as well as high heart and respiratory rates, particularly in mice, are tackled.
Collapse
Affiliation(s)
- Adrianus J Bakermans
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands; Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Desiree Abdurrachim
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Rik P M Moonen
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Abdallah G Motaal
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands; Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Jeanine J Prompers
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Gustav J Strijkers
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands; Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Katrien Vandoorne
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Klaas Nicolay
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| |
Collapse
|
8
|
Xu J, Qin Q, Wu D, Hua J, Song X, McMahon MT, Northington FJ, Zhang J, van Zijl PCM, Pekar JJ. Steady pulsed imaging and labeling scheme for noninvasive perfusion imaging. Magn Reson Med 2015; 75:238-48. [PMID: 25732958 DOI: 10.1002/mrm.25641] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2014] [Revised: 01/05/2015] [Accepted: 01/07/2015] [Indexed: 02/06/2023]
Abstract
PURPOSE A steady pulsed imaging and labeling (SPIL) scheme is proposed to obtain high-resolution multislice perfusion images of mice brain using standard preclinical MRI equipment. THEORY AND METHODS The SPIL scheme repeats a pulsed arterial spin labeling (PASL) module together with a short mixing time to extend the temporal duration of the generated PASL bolus to the total experimental time. Multislice image acquisition takes place during the mixing times. The mixing time is also used for magnetization recovery following image acquisition. The new scheme is able to yield multislice perfusion images rapidly. The perfusion kinetic curve can be measured by a multipulsed imaging and labeling (MPIL) scheme, i.e., acquiring single-slice ASL signals before reaching steady-state in the SPIL sequence. RESULTS When applying the SPIL method to normal mice, and to mice with unilateral ischemia, high-resolution multislice (five slices) CBF images could be obtained in 8 min. Perfusion data from ischemic mice showed clear CBF reductions in ischemic regions. The SPIL method was also applied to postmortem mice, showing that the method is free from magnetization transfer confounds. CONCLUSION The new SPIL scheme provides for robust measurement of CBF with multislice imaging capability in small animals.
Collapse
Affiliation(s)
- Jiadi Xu
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - Qin Qin
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - Dan Wu
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Jun Hua
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - Xiaolei Song
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Michael T McMahon
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - Frances J Northington
- Department of Pediatrics, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Jiangyang Zhang
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Peter C M van Zijl
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - James J Pekar
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| |
Collapse
|
9
|
Gutjahr FT, Kampf T, Winter P, Meyer CB, Williams T, Jakob PM, Bauer WR, Ziener CH, Helluy X. Quantification of perfusion in murine myocardium: A retrospectively triggered T1 -based ASL method using model-based reconstruction. Magn Reson Med 2014; 74:1705-15. [PMID: 25446550 DOI: 10.1002/mrm.25526] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2014] [Revised: 10/06/2014] [Accepted: 10/20/2014] [Indexed: 11/12/2022]
Abstract
PURPOSE A method for the quantification of perfusion in murine myocardium is demonstrated. The method allows for the reconstruction of perfusion maps on arbitrary time points in the heart cycle while addressing problems that arise due to the irregular heart beat of mice. METHODS A flow-sensitive alternating inversion recovery arterial spin labeling method using an untriggered FLASH-read out with random sampling is used. Look-Locker conditions are strictly maintained. No dummy pulses or mechanism to reduce deviation from Look-Locker conditions are needed. Electrocardiogram and respiratory data are recorded for retrospective gating and triggering. A model-based technique is used to reconstruct missing k-space data to cope with the undersampling inherent in retrospectively gated methods. Acquisition and reconstruction were validated numerically and in phantom measurements before in vivo experimentation. RESULTS Quantitative perfusion maps were acquired within a single slice measurement time of 11 min. Perfusion values are in good accordance to literature values. Myocardial infarction could be clearly visualized and results were confirmed with histological results. CONCLUSION The proposed method is capable of producing quantitative perfusion maps on arbitrary positions in the heart cycle within a short measurement time. The method is robust against irregular breathing patterns and heart rate changes and can be implemented on all scanners.
Collapse
Affiliation(s)
- Fabian T Gutjahr
- Universität Würzburg, Lehrstuhl für Experimentelle Physik 5, Am Hubland, 97074, Würzburg, Germany.,Comprehensive Heart Failure Center, Core Facility Imaging, Straubmühlweg 2a, 97078, Würzburg, Germany
| | - Thomas Kampf
- Universität Würzburg, Lehrstuhl für Experimentelle Physik 5, Am Hubland, 97074, Würzburg, Germany
| | - Patrick Winter
- Universität Würzburg, Lehrstuhl für Experimentelle Physik 5, Am Hubland, 97074, Würzburg, Germany
| | - Cord B Meyer
- Universität Würzburg, Lehrstuhl für Experimentelle Physik 5, Am Hubland, 97074, Würzburg, Germany
| | - Tatjana Williams
- Universität Würzburg, Medizinische Klinik und Poliklinik I, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Peter M Jakob
- Universität Würzburg, Lehrstuhl für Experimentelle Physik 5, Am Hubland, 97074, Würzburg, Germany
| | - Wolfgang R Bauer
- Universität Würzburg, Medizinische Klinik und Poliklinik I, Oberdürrbacher Straße 6, 97080, Würzburg, Germany
| | - Christian H Ziener
- German Cancer Research Center DKFZ, Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| | - Xavier Helluy
- Universität Würzburg, Lehrstuhl für Experimentelle Physik 5, Am Hubland, 97074, Würzburg, Germany
| |
Collapse
|
10
|
Bernard M, Jacquier A, Kober F. Cardiovascular magnetic resonance in ischemic heart disease. Future Cardiol 2014; 10:487-96. [PMID: 25301312 DOI: 10.2217/fca.14.39] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Ischemic heart disease is the major cause of death in developed countries. Recently, cardiovascular magnetic resonance (CMR) has appeared as a powerful technique for diagnosis and prognosis of ischemia, as well as for postischemic therapy follow-up. The objective of this chapter is to provide an overview of the role of CMR in assessing ischemic myocardium. It reviews the most recent studies in this field and includes CMR parameters that are already well established in the clinical setting as well as promising or emerging parameters in clinical use.
Collapse
Affiliation(s)
- Monique Bernard
- Aix-Marseille Université, CNRS, Centre de Résonance Magnétique Biologique et Médicale (CRMBM), UMR 7339, Faculté de Médecine, 27 Bd Jean Moulin 13385 Marseille, Cedex 5, France
| | | | | |
Collapse
|
11
|
Capron T, Troalen T, Robert B, Jacquier A, Bernard M, Kober F. Myocardial perfusion assessment in humans using steady-pulsed arterial spin labeling. Magn Reson Med 2014; 74:990-8. [DOI: 10.1002/mrm.25479] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2014] [Revised: 09/04/2014] [Accepted: 09/07/2014] [Indexed: 11/08/2022]
Affiliation(s)
- Thibaut Capron
- Aix-Marseille Université, UMR 7339, CNRS, CRMBM (Centre de Résonance Magnétique Biologique et Médicale); 13385 Marseille France
| | - Thomas Troalen
- Aix-Marseille Université, UMR 7339, CNRS, CRMBM (Centre de Résonance Magnétique Biologique et Médicale); 13385 Marseille France
| | | | - Alexis Jacquier
- Aix-Marseille Université, UMR 7339, CNRS, CRMBM (Centre de Résonance Magnétique Biologique et Médicale); 13385 Marseille France
| | - Monique Bernard
- Aix-Marseille Université, UMR 7339, CNRS, CRMBM (Centre de Résonance Magnétique Biologique et Médicale); 13385 Marseille France
| | - Frank Kober
- Aix-Marseille Université, UMR 7339, CNRS, CRMBM (Centre de Résonance Magnétique Biologique et Médicale); 13385 Marseille France
| |
Collapse
|
12
|
Troalen T, Capron T, Bernard M, Kober F. In vivo characterization of rodent cyclic myocardial perfusion variation at rest and during adenosine-induced stress using cine-ASL cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2014; 16:18. [PMID: 24548535 PMCID: PMC3937054 DOI: 10.1186/1532-429x-16-18] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2013] [Accepted: 02/10/2014] [Indexed: 01/09/2023] Open
Abstract
BACKGROUND Assessment of cyclic myocardial blood flow (MBF) variations can be an interesting addition to the characterization of microvascular function and its alterations. To date, totally non-invasive in vivo methods with this capability are still lacking. As an original technique, a cine arterial spin labeling (ASL) cardiovascular magnetic resonance approach is demonstrated to be able to produce dynamic MBF maps across the cardiac cycle in rats. METHOD High-resolution MBF maps in left ventricular myocardium were computed from steady-state perfusion-dependent gradient-echo cine images produced by the cine-ASL sequence. Cyclic changes of MBF over the entire cardiac cycle in seven normal rats were analyzed quantitatively every 6 ms at rest and during adenosine-induced stress. RESULTS The study showed a significant MBF increase from end-systole (ES) to end-diastole (ED) in both physiological states. Mean MBF over the cardiac cycle within the group was 5.5 ± 0.6 mL g(-1) min(-1) at rest (MBFMin = 4.7 ± 0.8 at ES and MBFMax = 6.5 ± 0.6 mL g(-1) min(-1) at ED, P = 0.0007). Mean MBF during adenosine-induced stress was 12.8 ± 0.7mL g(-1) min(-1) (MBFMin = 11.7±1.0 at ES and MBFMax = 14.2 ± 0.7 mL g(-1) min(-1) at ED, P = 0.0007). MBF percentage relative variations were significantly different with 27.2 ± 9.3% at rest and 17.8 ± 7.1% during adenosine stress (P = 0.014). The dynamic analysis also showed a time shift of peak MBF within the cardiac cycle during stress. CONCLUSION The cyclic change of myocardial perfusion was examined by mapping MBF with a steady-pulsed ASL approach. Dynamic MBF maps were obtained with high spatial and temporal resolution (6 ms) demonstrating the feasibility of non-invasively mapping cyclic myocardial perfusion variation at rest and during adenosine stress. In a pathological context, detailed assessment of coronary responses to infused vasodilators may give valuable complementary information on microvascular functional defects in disease models.
Collapse
Affiliation(s)
- Thomas Troalen
- Aix-Marseille Université, CNRS, CRMBM UMR 7339, 27 Bd Jean Moulin, 13385 Marseille Cedex 5, France
| | - Thibaut Capron
- Aix-Marseille Université, CNRS, CRMBM UMR 7339, 27 Bd Jean Moulin, 13385 Marseille Cedex 5, France
| | - Monique Bernard
- Aix-Marseille Université, CNRS, CRMBM UMR 7339, 27 Bd Jean Moulin, 13385 Marseille Cedex 5, France
| | - Frank Kober
- Aix-Marseille Université, CNRS, CRMBM UMR 7339, 27 Bd Jean Moulin, 13385 Marseille Cedex 5, France
| |
Collapse
|
13
|
|