Schmidt P, Lindemeyer J, Raut P, Schütz M, Saniternik S, Jönsson J, Endepols H, Fischer T, Quaas A, Schlößer HA, Thelen M, Grüll H. Multiparametric Characterization of the DSL-6A/C1 Pancreatic Cancer Model in Rats. Cancers (Basel) 2024; 16:1535. [PMID: 38672617 PMCID: PMC11049193 DOI: 10.3390/cancers16081535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 04/04/2024] [Accepted: 04/12/2024] [Indexed: 04/28/2024] Open
Abstract
The DSL-6A/C1 murine pancreatic ductal adenocarcinoma (PDAC) tumor model was established in Lewis rats and characterized through a comprehensive multiparametric analysis to compare it to other preclinical tumor models and explore potential diagnostic and therapeutical targets. DSL-6A/C1 tumors were histologically analyzed to elucidate PDAC features. The tumor microenvironment was studied for immune cell prevalence. Multiparametric MRI and PET imaging were utilized to characterize tumors, and 68Ga-FAPI-46-targeting cancer-associated fibroblasts (CAFs), were used to validate the histological findings. The histology confirmed typical PDAC characteristics, such as malformed pancreatic ductal malignant cells and CAFs. Distinct immune landscapes were identified, revealing an increased presence of CD8+ T cells and a decreased CD4+ T cell fraction within the tumor microenvironment. PET imaging with 68Ga-FAPI tracers exhibited strong tracer uptake in tumor tissues. The MRI parameters indicated increasing intralesional necrosis over time and elevated contrast media uptake in vital tumor areas. We have demonstrated that the DSL-6A/C1 tumor model, particularly due to its high tumorigenicity, tumor size, and 68Ga-FAPI-46 sensitivity, is a suitable alternative to established small animal models for many forms of preclinical analyses and therapeutic studies of PDAC.
Collapse
Affiliation(s)
- Patrick Schmidt
- Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, 50937 Cologne, Germany; (P.S.); (J.L.); (P.R.); (M.S.); (S.S.); (J.J.)
| | - Johannes Lindemeyer
- Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, 50937 Cologne, Germany; (P.S.); (J.L.); (P.R.); (M.S.); (S.S.); (J.J.)
| | - Pranali Raut
- Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, 50937 Cologne, Germany; (P.S.); (J.L.); (P.R.); (M.S.); (S.S.); (J.J.)
| | - Markus Schütz
- Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, 50937 Cologne, Germany; (P.S.); (J.L.); (P.R.); (M.S.); (S.S.); (J.J.)
- Faculty of Mathematics and Natural Sciences, Department of Chemistry, University of Cologne, 50937 Cologne, Germany
| | - Sven Saniternik
- Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, 50937 Cologne, Germany; (P.S.); (J.L.); (P.R.); (M.S.); (S.S.); (J.J.)
- Faculty of Mathematics and Natural Sciences, Department of Chemistry, University of Cologne, 50937 Cologne, Germany
| | - Jannika Jönsson
- Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, 50937 Cologne, Germany; (P.S.); (J.L.); (P.R.); (M.S.); (S.S.); (J.J.)
| | - Heike Endepols
- Faculty of Medicine and University Hospital of Cologne, Institute of Radiochemistry and Experimental Molecular Imaging, University of Cologne, 50937 Cologne, Germany;
- Faculty of Medicine and University Hospital of Cologne, Department of Nuclear Medicine, University of Cologne, 50937 Cologne, Germany;
- Nuclear Chemistry, Institute of Neuroscience and Medicine (INM-5), Forschungszentrum Jülich GmbH, 52425 Jülich, Germany
| | - Thomas Fischer
- Faculty of Medicine and University Hospital of Cologne, Department of Nuclear Medicine, University of Cologne, 50937 Cologne, Germany;
| | - Alexander Quaas
- Faculty of Medicine and University Hospital of Cologne, Institute of Pathology, University of Cologne, 50937 Cologne, Germany;
| | - Hans Anton Schlößer
- Center for Molecular Medicine Cologne, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany; (H.A.S.); (M.T.)
- Department of General, Visceral, Cancer and Transplantation Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany
| | - Martin Thelen
- Center for Molecular Medicine Cologne, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany; (H.A.S.); (M.T.)
| | - Holger Grüll
- Faculty of Medicine and University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, University of Cologne, 50937 Cologne, Germany; (P.S.); (J.L.); (P.R.); (M.S.); (S.S.); (J.J.)
- Faculty of Mathematics and Natural Sciences, Department of Chemistry, University of Cologne, 50937 Cologne, Germany
| |
Collapse
|
2
|
Slotman DJ, Bartels LW, Nijholt IM, Froeling M, Huirne JAF, Moonen CTW, Boomsma MF. Intravoxel incoherent motion (IVIM)-derived perfusion fraction mapping for the visual evaluation of MR-guided high intensity focused ultrasound (MR-HIFU) ablation of uterine fibroids. Int J Hyperthermia 2024; 41:2321980. [PMID: 38616245 DOI: 10.1080/02656736.2024.2321980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Accepted: 02/19/2024] [Indexed: 04/16/2024] Open
Abstract
BACKGROUND A method for periprocedural contrast agent-free visualization of uterine fibroid perfusion could potentially shorten magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) treatment times and improve outcomes. Our goal was to test feasibility of perfusion fraction mapping by intravoxel incoherent motion (IVIM) modeling using diffusion-weighted MRI as method for visual evaluation of MR-HIFU treatment progression. METHODS Conventional and T2-corrected IVIM-derived perfusion fraction maps were retrospectively calculated by applying two fitting methods to diffusion-weighted MRI data (b = 0, 50, 100, 200, 400, 600 and 800 s/mm2 at 1.5 T) from forty-four premenopausal women who underwent MR-HIFU ablation treatment of uterine fibroids. Contrast in perfusion fraction maps between areas with low perfusion fraction and surrounding tissue in the target uterine fibroid immediately following MR-HIFU treatment was evaluated. Additionally, the Dice similarity coefficient (DSC) was calculated between delineated areas with low IVIM-derived perfusion fraction and hypoperfusion based on CE-T1w. RESULTS Average perfusion fraction ranged between 0.068 and 0.083 in areas with low perfusion fraction based on visual assessment, and between 0.256 and 0.335 in surrounding tissues (all p < 0.001). DSCs ranged from 0.714 to 0.734 between areas with low perfusion fraction and the CE-T1w derived non-perfused areas, with excellent intraobserver reliability of the delineated areas (ICC 0.97). CONCLUSION The MR-HIFU treatment effect in uterine fibroids can be visualized using IVIM perfusion fraction mapping, in moderate concordance with contrast enhanced MRI. IVIM perfusion fraction mapping has therefore the potential to serve as a contrast agent-free imaging method to visualize the MR-HIFU treatment progression in uterine fibroids.
Collapse
Affiliation(s)
- Derk J Slotman
- Department of Radiology, Isala Hospital, Zwolle, The Netherlands
- Imaging & Oncology Division, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Lambertus W Bartels
- Imaging & Oncology Division, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Ingrid M Nijholt
- Department of Radiology, Isala Hospital, Zwolle, The Netherlands
- Imaging & Oncology Division, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Martijn Froeling
- Imaging & Oncology Division, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Judith A F Huirne
- Department of Obstetrics and Gynaecology, Amsterdam UMC, Amsterdam, The Netherlands
- Amsterdam Reproduction and Development, Amsterdam UMC, Amsterdam, The Netherlands
| | - Chrit T W Moonen
- Imaging & Oncology Division, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Martijn F Boomsma
- Department of Radiology, Isala Hospital, Zwolle, The Netherlands
- Imaging & Oncology Division, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
3
|
Richards N, Christensen D, Hillyard J, Kline M, Johnson S, Odéen H, Payne A. Evaluation of acoustic-thermal simulations of in vivo magnetic resonance guided focused ultrasound ablative therapy. Int J Hyperthermia 2024; 41:2301489. [PMID: 38234019 PMCID: PMC10903184 DOI: 10.1080/02656736.2023.2301489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 12/28/2023] [Indexed: 01/19/2024] Open
Abstract
PURPOSE To evaluate numerical simulations of focused ultrasound (FUS) with a rabbit model, comparing simulated heating characteristics with magnetic resonance temperature imaging (MRTI) data collected during in vivo treatment. METHODS A rabbit model was treated with FUS sonications in the biceps femoris with 3D MRTI collected. Acoustic and thermal properties of the rabbit muscle were determined experimentally. Numerical models of the rabbits were created, and tissue-type-specific properties were assigned. FUS simulations were performed using both the hybrid angular spectrum (HAS) method and k-Wave. Simulated power deposition patterns were converted to temperature maps using a Pennes' bioheat equation-based thermal solver. Agreement of pressure between the simulation techniques and temperature between the simulation and experimental heating was evaluated. Contributions of scattering and absorption attenuation were considered. RESULTS Simulated peak pressures derived using the HAS method exceeded the simulated peak pressures from k-Wave by 1.6 ± 2.7%. The location and FWHM of the peak pressure calculated from HAS and k-Wave showed good agreement. When muscle acoustic absorption value in the simulations was adjusted to approximately 54% of the measured attenuation, the average root-mean-squared error between simulated and experimental spatial-average temperature profiles was 0.046 ± 0.019 °C/W. Mean distance between simulated and experimental COTMs was 3.25 ± 1.37 mm. Transverse FWHMs of simulated sonications were smaller than in in vivo sonications. Longitudinal FWHMs were similar. CONCLUSIONS Presented results demonstrate agreement between HAS and k-Wave simulations and that FUS simulations can accurately predict focal position and heating for in vivo applications in soft tissue.
Collapse
Affiliation(s)
- Nicholas Richards
- Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, 84112, USA. USA
| | - Douglas Christensen
- Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, 84112, USA. USA
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah, 84132, USA
| | - Joshua Hillyard
- Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, 84112, USA. USA
| | - Michelle Kline
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, 84132
| | - Sara Johnson
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, 84132
| | - Henrik Odéen
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, 84132
| | - Allison Payne
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, 84132
| |
Collapse
|
4
|
Mattay RR, Kim K, Shah L, Shah B, Sugrue L, Safoora F, Ozhinsky E, Narsinh KH. MR Thermometry during Transcranial MR Imaging-Guided Focused Ultrasound Procedures: A Review. AJNR Am J Neuroradiol 2023; 45:1-8. [PMID: 38123912 PMCID: PMC10756580 DOI: 10.3174/ajnr.a8038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 08/04/2023] [Indexed: 12/23/2023]
Abstract
Interest in transcranial MR imaging-guided focused ultrasound procedures has recently grown. These incisionless procedures enable precise focal ablation of brain tissue using real-time monitoring by MR thermometry. This article will provide an updated review on clinically applicable technical underpinnings and considerations of proton resonance frequency MR thermometry, the most common clinically used MR thermometry sequence.
Collapse
Affiliation(s)
- Raghav R Mattay
- From the Department of Radiology and Biomedical Imaging (R.R.M., K.K., L. Sugrue, F.S., E.O., K.H.N.), University of California San Francisco, California
| | - Kisoo Kim
- From the Department of Radiology and Biomedical Imaging (R.R.M., K.K., L. Sugrue, F.S., E.O., K.H.N.), University of California San Francisco, California
| | - Lubdha Shah
- Department of Radiology and Neurosurgery (L. Shah), University of Utah, Salt Lake City, Utah
| | - Bhavya Shah
- Department of Radiology (B.S.), University of Texas Southwestern, Dallas, Texas
| | - Leo Sugrue
- From the Department of Radiology and Biomedical Imaging (R.R.M., K.K., L. Sugrue, F.S., E.O., K.H.N.), University of California San Francisco, California
- Department of Psychiatry (L. Sugrue), University of California San Francisco, California
| | - Fatima Safoora
- From the Department of Radiology and Biomedical Imaging (R.R.M., K.K., L. Sugrue, F.S., E.O., K.H.N.), University of California San Francisco, California
| | - Eugene Ozhinsky
- From the Department of Radiology and Biomedical Imaging (R.R.M., K.K., L. Sugrue, F.S., E.O., K.H.N.), University of California San Francisco, California
| | - Kazim H Narsinh
- From the Department of Radiology and Biomedical Imaging (R.R.M., K.K., L. Sugrue, F.S., E.O., K.H.N.), University of California San Francisco, California
- Department of Neurological Surgery (K.H.N.), University of California San Francisco, California
| |
Collapse
|
5
|
Edsall C, Fergusson A, Davis RM, Meyer CH, Allen SP, Vlaisavljevich E. Probability of Cavitation in a Custom Iron-Based Coupling Medium for Transcranial Magnetic Resonance-Guided Focused Ultrasound Procedures. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:2519-2526. [PMID: 37730478 PMCID: PMC10591864 DOI: 10.1016/j.ultrasmedbio.2023.08.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 06/13/2023] [Accepted: 08/16/2023] [Indexed: 09/22/2023]
Abstract
OBJECTIVE A coupling bath of circulating, chilled, degassed water is essential to safe and precise acoustic transmittance during transcranial magnetic resonance-guided focused ultrasound (tMRgFUS) procedures, but the circulating water impairs the critical real-time magnetic resonance imaging (MRI). An iron-based coupling medium (IBCM) using iron oxide nanoparticles previously developed by our group increased the relaxivity of the coupling bath such that it appears to be invisible on MRI compared with degassed water. However, the nanoparticles also reduced the pressure threshold for cavitation. To address this concern for prefocal cavitation, our group recently developed an IBCM of electrosterically stabilized and aggregation-resistant poly(methacrylic acid)-coated iron oxide nanoparticles (PMAA-FeOX) with a similar capability to reduce the MR signal of degassed water. This study examines the effect of the PMAA-FeOX IBCM on the cavitation threshold. METHODS Increasing concentrations of PMAA-FeOX nanoparticles in degassed, deionized water were placed at the focus of two different transducers to assess low and high duty-cycle pulsing parameters which are representative of two modes of focused ultrasound being investigated for tMRgFUS. Passive cavitation detection and high-speed optical imaging were used to measure cavitation threshold pressures. RESULTS The mean cavitation threshold was determined in both cases to be indistinguishable from the degassed water control, between 6-8 MPa for high duty-cycle pulsing (CW) and between 25.5-26.5 MPa for very low duty-cycle pulsing. CONCLUSION The findings of this study indicate that an IBCM of PMAA-FeOX nanoparticles is a possible solution to reducing MRI interference from the coupling bath without increasing the risk of prefocal cavitation.
Collapse
Affiliation(s)
- Connor Edsall
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
| | - Austin Fergusson
- Translational Biology, Medicine, and Health Graduate Program, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
| | - Richey M Davis
- Department of Chemical Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
| | - Craig H Meyer
- Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
| | - Steven P Allen
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT, USA
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA; ICTAS Center for Engineered Health, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA.
| |
Collapse
|
6
|
Zulkifli D, Manan HA, Yahya N, Hamid HA. The Applications of High-Intensity Focused Ultrasound (HIFU) Ablative Therapy in the Treatment of Primary Breast Cancer: A Systematic Review. Diagnostics (Basel) 2023; 13:2595. [PMID: 37568958 PMCID: PMC10417478 DOI: 10.3390/diagnostics13152595] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 07/14/2023] [Accepted: 07/23/2023] [Indexed: 08/13/2023] Open
Abstract
BACKGROUND This study evaluates the role of high-intensity focused ultrasound (HIFU) ablative therapy in treating primary breast cancer. METHODS PubMed and Scopus databases were searched according to the PRISMA guidelines to identify studies from 2002 to November 2022. Eligible studies were selected based on criteria such as experimental study type, the use of HIFU therapy as a treatment for localised breast cancer with objective clinical evaluation, i.e., clinical, radiological, and pathological outcomes. Nine studies were included in this study. RESULTS Two randomised controlled trials and seven non-randomised clinical trials fulfilled the inclusion criteria. The percentage of patients who achieved complete (100%) coagulation necrosis varied from 17% to 100% across all studies. Eight of the nine studies followed the treat-and-resect protocol in which HIFU-ablated tumours were surgically resected for pathological evaluation. Most breast cancers were single, solitary, and palpable breast tumours. Haematoxylin and eosin stains used for histopathological evaluation showed evidence of coagulation necrosis. Radiological evaluation by MRI showed an absence of contrast enhancement in the HIFU-treated tumour and 1.5 to 2 cm of normal breast tissue, with a thin peripheral rim of enhancement indicative of coagulation necrosis. All studies did not report severe complications, i.e., haemorrhage and infection. Common complications related to HIFU ablation were local mammary oedema, pain, tenderness, and mild to moderate burns. Only one third-degree burn was reported. Generally, the cosmetic outcome was good. The five-year disease-free survival rate was 95%, as reported in two RCTs. CONCLUSIONS HIFU ablation can induce tumour coagulation necrosis in localised breast cancer, with a favourable safety profile and cosmetic outcome. However, there is variable evidence of complete coagulation necrosis in the HIFU-treated tumour. Histopathological evidence of coagulation necrosis has been inconsistent, and there is no reliable radiological modality to assess coagulation necrosis confidently. Further exploration is needed to establish the accurate ablation margin with a reliable radiological modality for treatment and follow-up. HIFU therapy is currently limited to single, palpable breast tumours. More extensive and randomised clinical trials are needed to evaluate HIFU therapy for breast cancer, especially where the tumour is left in situ.
Collapse
Affiliation(s)
- Dania Zulkifli
- Functional Image Processing Laboratory, Department of Radiology, Universiti Kebangsaan Malaysia, Jalan Yaacob Latif, Bandar Tun Razak, Cheras, Kuala Lumpur 56000, Malaysia; (D.Z.); (H.A.H.)
| | - Hanani Abdul Manan
- Functional Image Processing Laboratory, Department of Radiology, Universiti Kebangsaan Malaysia, Jalan Yaacob Latif, Bandar Tun Razak, Cheras, Kuala Lumpur 56000, Malaysia; (D.Z.); (H.A.H.)
- Department of Radiology and Intervency, Hospital Pakar Kanak-Kanak (Children Specialist Hospital), Universiti Kebangsaan Malaysia, Jalan Yaacob Latif, Bandar Tun Razak, Kuala Lumpur 56000, Malaysia
| | - Noorazrul Yahya
- Diagnostic Imaging and Radiotherapy Program, Centre for Diagnostic, Therapeutic and Investigative Studies (CODTIS), Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abdul Aziz, Kuala Lumpur 50300, Malaysia
| | - Hamzaini Abdul Hamid
- Functional Image Processing Laboratory, Department of Radiology, Universiti Kebangsaan Malaysia, Jalan Yaacob Latif, Bandar Tun Razak, Cheras, Kuala Lumpur 56000, Malaysia; (D.Z.); (H.A.H.)
- Department of Radiology and Intervency, Hospital Pakar Kanak-Kanak (Children Specialist Hospital), Universiti Kebangsaan Malaysia, Jalan Yaacob Latif, Bandar Tun Razak, Kuala Lumpur 56000, Malaysia
| |
Collapse
|
7
|
Odéen H, Hofstetter LW, Payne AH, Guiraud L, Dumont E, Parker DL. Simultaneous proton resonance frequency T 1 - MR shear wave elastography for MR-guided focused ultrasound multiparametric treatment monitoring. Magn Reson Med 2023; 89:2171-2185. [PMID: 36656135 PMCID: PMC10940047 DOI: 10.1002/mrm.29587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 12/21/2022] [Accepted: 12/30/2022] [Indexed: 01/20/2023]
Abstract
PURPOSE To develop an efficient MRI pulse sequence to simultaneously measure multiple parameters that have been shown to correlate with tissue nonviability following thermal therapies. METHODS A 3D segmented EPI pulse sequence was used to simultaneously measure proton resonance frequency shift (PRFS) MR thermometry (MRT), T1 relaxation time, and shear wave velocity induced by focused ultrasound (FUS) push pulses. Experiments were performed in tissue mimicking gelatin phantoms and ex vivo bovine liver. Using a carefully designed FUS triggering scheme, a heating duty cycle of approximately 65% was achieved by interleaving FUS ablation pulses with FUS push pulses to induce shear waves in the tissue. RESULTS In phantom studies, temperature increases measured with PRFS MRT and increases in T1 correlated with decreased shear wave velocity, consistent with material softening with increasing temperature. During ablation in ex vivo liver, temperature increase measured with PRFS MRT initially correlated with increasing T1 and decreasing shear wave velocity, and after tissue coagulation with decreasing T1 and increasing shear wave velocity. This is consistent with a previously described hysteresis in T1 versus PRFS curves and increased tissue stiffness with tissue coagulation. CONCLUSION An efficient approach for simultaneous and dynamic measurements of PRSF, T1 , and shear wave velocity during treatment is presented. This approach holds promise for providing co-registered dynamic measures of multiple parameters, which correlates to tissue nonviability during and following thermal therapies, such as FUS.
Collapse
Affiliation(s)
- Henrik Odéen
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA
| | - Lorne W. Hofstetter
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA
| | - Allison H. Payne
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA
| | | | | | - Dennis L. Parker
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
8
|
Yao R, Hu J, Zhao W, Cheng Y, Feng C. A review of high-intensity focused ultrasound as a novel and non-invasive interventional radiology technique. J Interv Med 2022; 5:127-132. [PMID: 36317144 PMCID: PMC9617156 DOI: 10.1016/j.jimed.2022.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 05/23/2022] [Accepted: 06/07/2022] [Indexed: 11/19/2022] Open
Abstract
High-intensity focused ultrasound (HIFU) is a non-invasive interventional radiology technology, which has been generally accepted in clinical practice for the treatment of benign and malignant tumors. HIFU can cause targeted tissue coagulative necrosis and protein denaturation by thermal or non-thermal effects, guided by diagnostic ultrasound or magnetic resonance imaging, without destruction of the normal adjacent tissue, under sedation or general anesthesia. HIFU has become an important alternative to standard treatments of solid tumors, including surgery, radiation, and medications. The aim of this review is to describe the development, principle, devices, and clinical applications of HIFU.
Collapse
Affiliation(s)
- Ruihong Yao
- Medical Imaging Department, The First Affiliated Hospital of Kunming Medical University, Kunming, China
| | - Jihong Hu
- Medical Imaging Department, The First Affiliated Hospital of Kunming Medical University, Kunming, China
- Corresponding author.
| | - Wei Zhao
- Medical Imaging Department, The First Affiliated Hospital of Kunming Medical University, Kunming, China
| | - Yongde Cheng
- Editorial Board of the Journal of Interventional Medicine, Shanghai, China
| | - Chaofan Feng
- Medical Imaging Department, The First Affiliated Hospital of Kunming Medical University, Kunming, China
| |
Collapse
|
9
|
Lescrauwaet E, Vonck K, Sprengers M, Raedt R, Klooster D, Carrette E, Boon P. Recent Advances in the Use of Focused Ultrasound as a Treatment for Epilepsy. Front Neurosci 2022; 16:886584. [PMID: 35794951 PMCID: PMC9251412 DOI: 10.3389/fnins.2022.886584] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Accepted: 05/30/2022] [Indexed: 12/02/2022] Open
Abstract
Epilepsy affects about 1% of the population. Approximately one third of patients with epilepsy are drug-resistant (DRE). Resective surgery is an effective treatment for DRE, yet invasive, and not all DRE patients are suitable resective surgery candidates. Focused ultrasound, a novel non-invasive neurointerventional method is currently under investigation as a treatment alternative for DRE. By emitting one or more ultrasound waves, FUS can target structures in the brain at millimeter resolution. High intensity focused ultrasound (HIFU) leads to ablation of tissue and could therefore serve as a non-invasive alternative for resective surgery. It is currently under investigation in clinical trials following the approval of HIFU for essential tremor and Parkinson’s disease. Low intensity focused ultrasound (LIFU) can modulate neuronal activity and could be used to lower cortical neuronal hyper-excitability in epilepsy patients in a non-invasive manner. The seizure-suppressive effect of LIFU has been studied in several preclinical trials, showing promising results. Further investigations are required to demonstrate translation of preclinical results to human subjects.
Collapse
Affiliation(s)
- Emma Lescrauwaet
- 4Brain Lab, Department of Neurology, Ghent University Hospital, Ghent, Belgium
- *Correspondence: Emma Lescrauwaet,
| | - Kristl Vonck
- 4Brain Lab, Department of Neurology, Ghent University Hospital, Ghent, Belgium
| | - Mathieu Sprengers
- 4Brain Lab, Department of Neurology, Ghent University Hospital, Ghent, Belgium
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Robrecht Raedt
- 4Brain Lab, Department of Neurology, Ghent University Hospital, Ghent, Belgium
| | - Debby Klooster
- 4Brain Lab, Department of Neurology, Ghent University Hospital, Ghent, Belgium
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Evelien Carrette
- 4Brain Lab, Department of Neurology, Ghent University Hospital, Ghent, Belgium
| | - Paul Boon
- 4Brain Lab, Department of Neurology, Ghent University Hospital, Ghent, Belgium
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| |
Collapse
|
10
|
Zimmerman BE, Johnson SL, Odéen HA, Shea JE, Factor RE, Joshi SC, Payne AH. Histology to 3D in vivo MR registration for volumetric evaluation of MRgFUS treatment assessment biomarkers. Sci Rep 2021; 11:18923. [PMID: 34556678 PMCID: PMC8460731 DOI: 10.1038/s41598-021-97309-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Accepted: 08/24/2021] [Indexed: 11/09/2022] Open
Abstract
Advances in imaging and early cancer detection have increased interest in magnetic resonance (MR) guided focused ultrasound (MRgFUS) technologies for cancer treatment. MRgFUS ablation treatments could reduce surgical risks, preserve organ tissue and function, and improve patient quality of life. However, surgical resection and histological analysis remain the gold standard to assess cancer treatment response. For non-invasive ablation therapies such as MRgFUS, the treatment response must be determined through MR imaging biomarkers. However, current MR biomarkers are inconclusive and have not been rigorously evaluated against histology via accurate registration. Existing registration methods rely on anatomical features to directly register in vivo MR and histology. For MRgFUS applications in anatomies such as liver, kidney, or breast, anatomical features that are not caused by the treatment are often insufficient to drive direct registration. We present a novel MR to histology registration workflow that utilizes intermediate imaging and does not rely on anatomical MR features being visible in histology. The presented workflow yields an overall registration accuracy of 1.00 ± 0.13 mm. The developed registration pipeline is used to evaluate a common MRgFUS treatment assessment biomarker against histology. Evaluating MR biomarkers against histology using this registration pipeline will facilitate validating novel MRgFUS biomarkers to improve treatment assessment without surgical intervention. While the presented registration technique has been evaluated in a MRgFUS ablation treatment model, this technique could be potentially applied in any tissue to evaluate a variety of therapeutic options.
Collapse
Affiliation(s)
- Blake E Zimmerman
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA. .,Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT, USA.
| | - Sara L Johnson
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA.,Utah Center for Advanced Imaging Research, University of Utah, Salt Lake City, UT, USA
| | - Henrik A Odéen
- Utah Center for Advanced Imaging Research, University of Utah, Salt Lake City, UT, USA
| | - Jill E Shea
- Department of Surgery, University of Utah, Salt Lake City, UT, USA
| | - Rachel E Factor
- Department of Pathology, University of Utah, Salt Lake City, UT, USA
| | - Sarang C Joshi
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA.,Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT, USA
| | - Allison H Payne
- Utah Center for Advanced Imaging Research, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
11
|
Payne A, Chopra R, Ellens N, Chen L, Ghanouni P, Sammet S, Diederich C, Ter Haar G, Parker D, Moonen C, Stafford J, Moros E, Schlesinger D, Benedict S, Wear K, Partanen A, Farahani K. AAPM Task Group 241: A medical physicist's guide to MRI-guided focused ultrasound body systems. Med Phys 2021; 48:e772-e806. [PMID: 34224149 DOI: 10.1002/mp.15076] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 04/28/2021] [Accepted: 06/21/2021] [Indexed: 11/07/2022] Open
Abstract
Magnetic resonance-guided focused ultrasound (MRgFUS) is a completely non-invasive technology that has been approved by FDA to treat several diseases. This report, prepared by the American Association of Physicist in Medicine (AAPM) Task Group 241, provides background on MRgFUS technology with a focus on clinical body MRgFUS systems. The report addresses the issues of interest to the medical physics community, specific to the body MRgFUS system configuration, and provides recommendations on how to successfully implement and maintain a clinical MRgFUS program. The following sections describe the key features of typical MRgFUS systems and clinical workflow and provide key points and best practices for the medical physicist. Commonly used terms, metrics and physics are defined and sources of uncertainty that affect MRgFUS procedures are described. Finally, safety and quality assurance procedures are explained, the recommended role of the medical physicist in MRgFUS procedures is described, and regulatory requirements for planning clinical trials are detailed. Although this report is limited in scope to clinical body MRgFUS systems that are approved or currently undergoing clinical trials in the United States, much of the material presented is also applicable to systems designed for other applications.
Collapse
Affiliation(s)
- Allison Payne
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Rajiv Chopra
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA
| | | | - Lili Chen
- Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, USA
| | - Pejman Ghanouni
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Steffen Sammet
- Department of Radiology, University of Chicago, Chicago, IL, USA
| | - Chris Diederich
- Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, USA
| | | | - Dennis Parker
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Chrit Moonen
- Imaging Division, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Jason Stafford
- Department of Imaging Physics, MD Anderson Cancer Center, Houston, TX, USA
| | - Eduardo Moros
- Department of Radiation Oncology, Moffitt Cancer Center, Tampa, FL, USA
| | - David Schlesinger
- Department of Radiation Oncology, University of Virginia, Charlottesville, VA, USA
| | | | - Keith Wear
- U.S. Food and Drug Administration, Silver Spring, MD, USA
| | | | - Keyvan Farahani
- National Cancer Institute, National Institutes of Health, Rockville, MD, USA
| |
Collapse
|
12
|
Morchi L, Mariani A, Diodato A, Tognarelli S, Cafarelli A, Menciassi A. Acoustic Coupling Quantification in Ultrasound-Guided Focused Ultrasound Surgery: Simulation-Based Evaluation and Experimental Feasibility Study. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:3305-3316. [PMID: 33004236 DOI: 10.1016/j.ultrasmedbio.2020.08.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2020] [Revised: 07/17/2020] [Accepted: 08/30/2020] [Indexed: 05/07/2023]
Abstract
Adequate acoustic coupling between the therapeutic transducer and the patient's body is essential for safe and efficient focused ultrasound surgery (FUS). There is currently no quantitative method for acoustic coupling verification in ultrasound-guided FUS. In this work, a quantitative method was developed and a related metric was introduced: the acoustic coupling coefficient. This metric associates the adequacy of the acoustic coupling with the reflected signals recorded through an imaging probe during a low-energy sonication. The acoustic coupling issue was simulated in silico and validated through in vitro tests. Our results indicated a sigmoidal behavior of the introduced metric as the contact surface between the coupling system and the patient's skin increases. The proposed method could be a safety-check criterion for verifying the adequacy of the acoustic coupling before starting the FUS treatment, thus ensuring efficient energy transmission to the target and preventing damage to both the patient and the instrumentation.
Collapse
Affiliation(s)
- Laura Morchi
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy.
| | - Andrea Mariani
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Alessandro Diodato
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy; River Global Scientific Lab, srl, Pisa, Italy
| | - Selene Tognarelli
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Andrea Cafarelli
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy; River Global Scientific Lab, srl, Pisa, Italy
| | - Arianna Menciassi
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| |
Collapse
|
13
|
Magnetic resonance imaging of the prostate after focal therapy with high-intensity focused ultrasound. Abdom Radiol (NY) 2020; 45:3882-3895. [PMID: 32447414 DOI: 10.1007/s00261-020-02577-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
For clinically significant, locally confined prostate cancer, whole-gland radical prostatectomy and radiotherapy are established effective treatment strategies that, however, come at a cost of significant morbidity related to urinary and sexual side effects. The concept of risk stratification paired with a better understanding of prognostic factors has led to the development of alternative management options including active surveillance and focal therapy for appropriately selected patients with localized disease. High-intensity focused ultrasound (HIFU) is one such minimally invasive, image-guided treatment option for prostate cancer. Due to the relative novelty of HIFU and the increased use of magnetic resonance imaging in prostate cancer, many radiologists are not yet familiar with imaging findings related to HIFU, their temporal evolution as well as imaging appearance of recurrent disease after this type of focal therapy. HIFU induces sharply demarcated, localized coagulative necrosis of a tumor through thermal energy delivered via an endorectal or transurethral ultrasound transducer. In this pictorial review, we aim at providing relevant background information that will guide the reader through the general principles of HIFU in the prostate, as well as demonstrate the imaging appearance of expected post-HIFU changes versus recurrent tumor.
Collapse
|
14
|
Zimmerman BE, Johnson S, Odeen H, Shea J, Foote MD, Winkler N, Joshi SC, Payne A. Learning Multiparametric Biomarkers for Assessing MR-Guided Focused Ultrasound Treatment of Malignant Tumors. IEEE Trans Biomed Eng 2020; 68:1737-1747. [PMID: 32946378 DOI: 10.1109/tbme.2020.3024826] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Noninvasive MR-guided focused ultrasound (MRgFUS) treatments are promising alternatives to the surgical removal of malignant tumors. A significant challenge is assessing the viability of treated tissue during and immediately after MRgFUS procedures. Current clinical assessment uses the nonperfused volume (NPV) biomarker immediately after treatment from contrast-enhanced MRI. The NPV has variable accuracy, and the use of contrast agent prevents continuing MRgFUS treatment if tumor coverage is inadequate. This work presents a novel, noncontrast, learned multiparametric MR biomarker that can be used during treatment for intratreatment assessment, validated in a VX2 rabbit tumor model. A deep convolutional neural network was trained on noncontrast multiparametric MR images using the NPV biomarker from follow-up MR imaging (3-5 days after MRgFUS treatment) as the accurate label of nonviable tissue. A novel volume-conserving registration algorithm yielded a voxel-wise correlation between treatment and follow-up NPV, providing a rigorous validation of the biomarker. The learned noncontrast multiparametric MR biomarker predicted the follow-up NPV with an average DICE coefficient of 0.71, substantially outperforming the current clinical standard (DICE coefficient = 0.53). Noncontrast multiparametric MR imaging integrated with a deep convolutional neural network provides a more accurate prediction of MRgFUS treatment outcome than current contrast-based techniques.
Collapse
|
15
|
Ma Y, Li H, Ji X, Lu C, Huang N, Zhang M, Ge H. Experimental study of water/tissue conductivity variation under 1 MHz HIFU radiation. Biomed Signal Process Control 2020. [DOI: 10.1016/j.bspc.2020.102065] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
16
|
Ma Y, Hsu G, Zhang F. The applicability and efficacy of magnetic resonance-guided high intensity focused ultrasound system in the treatment of primary trigeminal neuralgia. Med Hypotheses 2020; 139:109688. [PMID: 32240878 DOI: 10.1016/j.mehy.2020.109688] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Accepted: 03/23/2020] [Indexed: 12/27/2022]
Abstract
Primary trigeminal neuralgia is a common clinical refractory neuralgia characterized by an onset of excruciating pain that can severely affect patients' quality of life. Long-term suffering from this pain may lead to depression, anxiety, and suicide. Current treatments, however, are associated with high recurrent rates and severe complications. We hypothesize that both the applicability and efficacy of magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) treatment in primary trigeminal neuralgia can be achieved under the following conditions: a specific target focus and incident channel, a temperature measurement system that does not incur damage to surrounding tissues, and an optimal radiation dose. Successful non-invasive treatment of primary trigeminal neuralgia by MR-HIFU systems could represent a breakthrough of this technology applied to the oral and maxillofacial region.
Collapse
Affiliation(s)
- Yaping Ma
- Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Stomatological Hospital of Chongqing Medical University, Chongqing 401147, China; Department of Oral and Maxillofacial Surgery, Stomatological Hospital of Chongqing Medical University, Chongqing 401147, China
| | - Grace Hsu
- Department of Oral and Maxillofacial Surgery, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Fugui Zhang
- Department of Oral and Maxillofacial Surgery, Stomatological Hospital of Chongqing Medical University, Chongqing 401147, China; Department of Oral and Maxillofacial Surgery, Massachusetts General Hospital, Boston, MA 02114, USA.
| |
Collapse
|
17
|
Connor MJ, Gorin MA, Ahmed HU, Nigam R. Focal therapy for localized prostate cancer in the era of routine multi-parametric MRI. Prostate Cancer Prostatic Dis 2020; 23:232-243. [PMID: 32051551 DOI: 10.1038/s41391-020-0206-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Revised: 01/16/2020] [Accepted: 01/20/2020] [Indexed: 01/19/2023]
Abstract
BACKGROUND Prostate cancer focal therapy aims to minimize the side-effects of whole gland treatments, such as radical prostatectomy and radiotherapy without compromising oncological efficacy. However, concerns exist regarding the multifocal nature of prostate cancer and the lack of long-term oncological data for this form of treatment. In recent years, the routine adoption of multi-parametric magnetic resonance imaging (mpMRI) of the prostate has improved our ability to select candidates for focal therapy and to accurately deliver this form of prostate cancer treatment. METHODS We performed a review of the literature to provide a summary of the oncological and functional outcomes of men receiving primary prostate focal therapy. Furthermore, we discuss the impact of the routine implementation of mpMRI as part of the initial prostate cancer diagnostic pathway on the selection of candidates and delivery of focal therapy. Finally, we summarize knowledge gaps in the field and highlight active clinical trials in this arena. RESULTS Primary focal therapy involves the application of one of a number of energies that ablate tissue, such as cryotherapy and high intensity focused ultrasound (HIFU). Success is principally dependent on highly accurate patient selection and disease localization underpinned in large part by the routine integration of pre-biopsy mpMRI. Prospective medium-term follow-up data for primary HIFU and cryotherapy for men with intermediate-risk disease have shown acceptable cancer control with low risk of side effects and complications. Additional research is needed to clearly define an appropriate follow-up approach and to guide the management of in- and out-of-field recurrences. Multiple comparative trials with randomization against standard care are currently underway in men with intermediate- and high-risk prostate cancer. CONCLUSION The widespread adoption of prostate mpMRI has led to improved disease localization, enabling the performance of focal therapy as a viable treatment strategy for men with low volume intermediate-risk prostate cancer.
Collapse
Affiliation(s)
- M J Connor
- Imperial Prostate, Division of Surgery, Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, Charing Cross Hospital, London, W6 8RF, UK. .,Imperial Urology, Imperial College Healthcare NHS Trust, Charing Cross Hospital, London, W6 8RF, UK.
| | - M A Gorin
- The James Buchanan Brady Urological Institute and Department of Urology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - H U Ahmed
- Imperial Prostate, Division of Surgery, Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, Charing Cross Hospital, London, W6 8RF, UK.,Imperial Urology, Imperial College Healthcare NHS Trust, Charing Cross Hospital, London, W6 8RF, UK
| | - R Nigam
- Royal Surrey NHS Foundation Trust, Guildford, Surrey, GU2 7XX, UK.,University College London Hospital, 235 Euston Road, London, NW1 2BU, UK
| |
Collapse
|
18
|
The Focused Ultrasound Myoma Outcome Study (FUMOS); a retrospective cohort study on long-term outcomes of MR-HIFU therapy. Eur Radiol 2020; 30:2473-2482. [DOI: 10.1007/s00330-019-06641-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 11/15/2019] [Accepted: 12/17/2019] [Indexed: 01/24/2023]
|
19
|
de Maar JS, Sofias AM, Porta Siegel T, Vreeken RJ, Moonen C, Bos C, Deckers R. Spatial heterogeneity of nanomedicine investigated by multiscale imaging of the drug, the nanoparticle and the tumour environment. Am J Cancer Res 2020; 10:1884-1909. [PMID: 32042343 PMCID: PMC6993242 DOI: 10.7150/thno.38625] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Accepted: 11/13/2019] [Indexed: 02/07/2023] Open
Abstract
Genetic and phenotypic tumour heterogeneity is an important cause of therapy resistance. Moreover, non-uniform spatial drug distribution in cancer treatment may cause pseudo-resistance, meaning that a treatment is ineffective because the drug does not reach its target at sufficient concentrations. Together with tumour heterogeneity, non-uniform drug distribution causes “therapy heterogeneity”: a spatially heterogeneous treatment effect. Spatial heterogeneity in drug distribution occurs on all scales ranging from interpatient differences to intratumour differences on tissue or cellular scale. Nanomedicine aims to improve the balance between efficacy and safety of drugs by targeting drug-loaded nanoparticles specifically to tumours. Spatial heterogeneity in nanoparticle and payload distribution could be an important factor that limits their efficacy in patients. Therefore, imaging spatial nanoparticle distribution and imaging the tumour environment giving rise to this distribution could help understand (lack of) clinical success of nanomedicine. Imaging the nanoparticle, drug and tumour environment can lead to improvements of new nanotherapies, increase understanding of underlying mechanisms of heterogeneous distribution, facilitate patient selection for nanotherapies and help assess the effect of treatments that aim to reduce heterogeneity in nanoparticle distribution. In this review, we discuss three groups of imaging modalities applied in nanomedicine research: non-invasive clinical imaging methods (nuclear imaging, MRI, CT, ultrasound), optical imaging and mass spectrometry imaging. Because each imaging modality provides information at a different scale and has its own strengths and weaknesses, choosing wisely and combining modalities will lead to a wealth of information that will help bring nanomedicine forward.
Collapse
|
20
|
Kokuryo D, Kumamoto E, Kuroda K. Recent technological advancements in thermometry. Adv Drug Deliv Rev 2020; 163-164:19-39. [PMID: 33217482 DOI: 10.1016/j.addr.2020.11.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2020] [Revised: 07/25/2020] [Accepted: 11/02/2020] [Indexed: 12/12/2022]
Abstract
Thermometry is the key factor for achieving successful thermal therapy. Although invasive thermometry with a probe has been used for more than four decades, this method can only detect the local temperature within the probing volume. Noninvasive temperature imaging using a tomographic technique is ideal for monitoring hot-spot formation in the human body. Among various techniques, such as X-ray computed tomography, microwave tomography, echo sonography, and magnetic resonance (MR) imaging, the proton resonance frequency shift method of MR thermometry is the only method currently available for clinical practice because its temperature sensitivity is consistent in most aqueous tissues and can be easily observed using common clinical scanners. New techniques are being proposed to improve the robustness of this method against tissue motion. MR techniques for fat thermometry were also developed based on relaxation times. One of the latest non-MR techniques to attract attention is photoacoustic imaging.
Collapse
Affiliation(s)
- Daisuke Kokuryo
- Graduate School of System Informatics, Kobe University, Japan
| | - Etsuko Kumamoto
- Information Science and Technology Center, Kobe University, Japan
| | - Kagayaki Kuroda
- School of Information Science and Technology, Tokai University, Japan; Center for Frontier Medical Engineering, Chiba University, Japan.
| |
Collapse
|
21
|
Morochnik S, Ozhinsky E, Rieke V, Bucknor MD. T2 mapping as a predictor of nonperfused volume in MRgFUS treatment of desmoid tumors. Int J Hyperthermia 2019; 36:1272-1277. [PMID: 31822140 DOI: 10.1080/02656736.2019.1698773] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
Abstract
Objective: The objective of this study was to develop an alternative method of non-contrast monitoring of tissue ablation during focused ultrasound treatment. Desmoid tumors are benign but locally aggressive soft tissue tumors that arise from fibroblast cells. Magnetic resonance-guided focused ultrasound (MRgFUS) has emerged as an alternative to conventional therapies, showing promising results in reduction of tumor volume without significant side effects. The gold-standard assessment of the reduction of viable tumor volume post-treatment is non-perfused volume (NPV) and evaluation of NPV is typically performed with post-treatment gadolinium enhanced MR imaging. However, as gadolinium cannot be repeatedly administered during treatments, there is a need for alternative non-contrast monitoring of the tissue to prevent over and under treatment. Methods: Double-echo and multi-echo images were acquired before, during and after the MRgFUS treatment. T2 maps were generated with an exponential fit and T2 maps were compared to post-treatment post-contrast images.Results: In all five MRgFUS treatment sessions, T2 mapping showed excellent qualitative agreement with the post-contrast NPV.Conclusions: T2 mapping may be used to visualize the extent of ablation with focused ultrasound and can be used as a predictor of NPV prior to the administration of contrast during the post-treatment assessment.
Collapse
Affiliation(s)
- Simona Morochnik
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Eugene Ozhinsky
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Viola Rieke
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Matthew D Bucknor
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| |
Collapse
|
22
|
Allen SP, Steeves T, Fergusson A, Moore D, Davis RM, Vlaisialjevich E, Meyer CH. Novel acoustic coupling bath using magnetite nanoparticles for MR-guided transcranial focused ultrasound surgery. Med Phys 2019; 46:5444-5453. [PMID: 31605643 DOI: 10.1002/mp.13863] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Revised: 09/26/2019] [Accepted: 10/08/2019] [Indexed: 01/26/2023] Open
Abstract
PURPOSE Acoustic coupling baths, nominally composed of degassed water, play important roles during transcranial focused ultrasound surgery. However, this large water bolus also degrades the quality of intraoperative magnetic resonance (MR) guidance imaging. In this study, we test the feasibility of using dilute, aqueous magnetite nanoparticle suspensions to suppress these image degradations while preserving acoustic compatibility. We examine the effects of these suspensions on metrics of image quality and acoustic compatibility for two types of transcranial focused ultrasound insonation regimes: low-duty cycle histotripsy procedures and high-duty cycle thermal ablation procedures. METHODS Magnetic resonance guidance imaging was used to monitor thermal ablations of in vitro gel targets using a coupling bath composed of various concentrations of aqueous, suspended, magnetite nanoparticles in a clinical transcranial transducer under stationary and flowing conditions. Thermal deposition was monitored using MR thermometry simultaneous to insonation. Then, using normal degassed water as a coupling bath, various concentrations of aqueous, suspended, magnetite nanoparticles were placed at the center of this same transducer and insonated using high-duty cycle pulsing parameters. Passive cavitation detectors recorded cavitation emissions, which were then used to estimate the relative number of cavitation events per insonation (cavitation duty cycle) and the cavitation dose estimates of each nanoparticle concentration. Finally, the nanoparticle mixtures were exposed to low-duty cycle, histotripsy pulses. Passive cavitation detectors monitored cavitation emissions, which were used to estimate cavitation threshold pressures. RESULTS The nanoparticles reduced the MR signal of the coupling bath by 90% in T2- and T2*-weighted images and also removed almost all imaging artifacts caused by coupling bath motion. The coupling baths caused <5% changes in peak temperature change achieved during sonication, as observed via MR thermometry. At low duty cycle insonations, the nanoparticles decreased the cavitation threshold pressure by about 15 ± 7% in a manner uncorrelated with nanoparticle concentration. At high duty cycle insonations, the 0.5 cavitation duty cycle acoustic power threshold varied linearly with nanoparticle concentration. CONCLUSIONS Dilute aqueous magnetite nanoparticle suspensions effectively reduced MR imaging artifacts caused by the acoustic coupling bath. They also attenuated acoustic power deposition by <5%. For low duty cycle insonation regimes, the nanoparticles decreased the cavitation threshold by 15 ± 7%. However, for high-duty cycle regimes, the nanoparticles decreased the threshold for cavitation in proportion to nanoparticle concentration.
Collapse
Affiliation(s)
- Steven P Allen
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
| | - Tom Steeves
- Department of Mechanical Engineering, Virginia Tech, Blacksburg, VA, USA
| | - Austin Fergusson
- Graduate Program in Translational Biology, Medicine, and Health, Virginia Tech, Blacksburg, VA, USA
| | - Dave Moore
- The Focused Ultrasound Foundation, Charlottesville, VA, USA
| | - Richey M Davis
- Department of Chemical Engineering, Virginia Tech, Blacksburg, VA, USA
| | - Eli Vlaisialjevich
- Graduate Program in Translational Biology, Medicine, and Health, Virginia Tech, Blacksburg, VA, USA.,Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA, USA
| | - Craig H Meyer
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA.,Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, USA
| |
Collapse
|
23
|
MacDonell J, Patel N, Fischer G, Burdette EC, Qian J, Chumbalkar V, Ghoshal G, Heffter T, Williams E, Gounis M, King R, Thibodeau J, Bogdanov G, Brooks OW, Langan E, Hwang R, Pilitsis JG. Robotic Assisted MRI-Guided Interventional Interstitial MR-Guided Focused Ultrasound Ablation in a Swine Model. Neurosurgery 2019; 84:1138-1148. [PMID: 29905844 PMCID: PMC6500887 DOI: 10.1093/neuros/nyy266] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Accepted: 05/21/2018] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Ablative lesions are current treatments for epilepsy and brain tumors. Interstitial magnetic resonance (MR) guided focused ultrasound (iMRgFUS) may be an alternate ablation technique which limits thermal tissue charring as compared to laser therapy (LITT) and can produce larger ablation patterns nearer the surface than transcranial MR guided focused ultrasound (tcMRgFUS). OBJECTIVE To describe our experience with interstitial focused ultrasound (iFUS) ablations in swine, using MR-guided robotically assisted (MRgRA) delivery. METHODS In an initial 3 animals, we optimized the workflow of the robot in the MR suite and made modifications to the robotic arm to allow range of motion. Then, 6 farm pigs (4 acute, 2 survival) underwent 7 iMRgFUS ablations using MRgRA. We altered dosing to explore differences between thermal dosing in brain as compared to other tissues. Imaging was compared to gross examination. RESULTS Our work culminated in adjustments to the MRgRA, iMRgFUS probes, and dosing, culminating in 2 survival surgeries; swine had ablations with no neurological sequelae at 2 wk postprocedure. Immediately following iMRgFUS therapy, diffusion-weighted imaging, and T1 weighted MR were accurate reflections of the ablation volume. T2 and fluid-attenuated inversion-recovery (FLAIR) images were accurate reflections of ablation volume 1-wk postprocedure. CONCLUSION We successfully performed MRgRA iFUS ablation in swine and found intraoperative and postoperative imaging to correlate with histological examination. These data are useful to validate our system and to guide imaging follow-up for thermal ablation lesions in brain tissue from our therapy, tcMRgFUS, and LITT.
Collapse
Affiliation(s)
| | - Niravkumar Patel
- Department of Mechanical Engineering, Worcester Polytechnic Institute, Worcester, Massachusetts
| | - Gregory Fischer
- Department of Mechanical Engineering, Worcester Polytechnic Institute, Worcester, Massachusetts
| | | | - Jiang Qian
- Department of Pathology, Albany Medical College, Albany, New York
| | | | | | | | | | - Matthew Gounis
- Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts
| | - Robert King
- Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts
| | | | - Gene Bogdanov
- Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts
| | - Olivia W Brooks
- Department of Radiology, New England Center for Stroke Research, University of Massachusetts Medical School, Worcester, Massachusetts
| | - Erin Langan
- Department of Radiology, New England Center for Stroke Research, University of Massachusetts Medical School, Worcester, Massachusetts
| | - Roy Hwang
- Department of Neurosurgery, Albany Medical College, Albany, New York
| | - Julie G Pilitsis
- Department of Neurosurgery, Albany Medical College, Albany, New York
- Department of Neuroscience and Experimental Therapeutics, Albany Medical College, Albany, New York
| |
Collapse
|
24
|
Odéen H, de Bever J, Hofstetter LW, Parker DL. Multiple-point magnetic resonance acoustic radiation force imaging. Magn Reson Med 2018; 81:1104-1117. [PMID: 30257059 PMCID: PMC6642829 DOI: 10.1002/mrm.27477] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Revised: 07/09/2018] [Accepted: 07/11/2018] [Indexed: 12/13/2022]
Abstract
PURPOSE To implement and evaluate an efficient multiple-point MR acoustic radiation force imaging pulse sequence that can volumetrically measure tissue displacement and evaluate tissue stiffness using focused ultrasound (FUS) radiation force. METHODS Bipolar motion-encoding gradients were added to a gradient-recalled echo segmented EPI pulse sequence with both 2D and 3D acquisition modes. Multiple FUS-ON images (FUS power > 0 W) were interleaved with a single FUS-OFF image (FUS power = 0 W) on the TR level, enabling simultaneous measurements of volumetric tissue displacement (by complex subtraction of the FUS-OFF image from the FUS-ON images) and proton resonance frequency shift MR thermometry (from the OFF image). Efficiency improvements included partial Fourier acquisition, parallel imaging, and encoding up to 4 different displacement positions into a single image. Experiments were performed in homogenous and dual-stiffness phantoms, and in ex vivo porcine brain. RESULTS In phantoms, 16-point multiple-point magnetic resonance acoustic radiation force imaging maps could be acquired in 5 s to 10 s for a 2D slice, and 60 s for a 3D volume, using parallel imaging and encoding 2 displacement positions/image. In ex vivo porcine brain, 16-point multiple-point magnetic resonance acoustic radiation force imaging maps could be acquired in 20 s for a 3D volume, using partial Fourier and parallel imaging and encoding 4 displacement positions/image. In 1 experiment it was observed that tissue displacement in ex vivo brain decreased by approximately 22% following FUS ablation. CONCLUSION With the described efficiency improvements it is possible to acquire volumetric multiple-point magnetic resonance acoustic radiation force imaging maps, with simultaneous proton resonance frequency shift MR thermometry maps, in clinically acceptable times.
Collapse
Affiliation(s)
- Henrik Odéen
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah
| | - Joshua de Bever
- Department of Radiology, Stanford University, Palo Alto, California
| | - Lorne W Hofstetter
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah
| | - Dennis L Parker
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah
| |
Collapse
|
25
|
Giles SL, Winfield JM, Collins DJ, Rivens I, Civale J, ter Haar GR, deSouza NM. Value of diffusion-weighted imaging for monitoring tissue change during magnetic resonance-guided high-intensity focused ultrasound therapy in bone applications: an ex-vivo study. Eur Radiol Exp 2018; 2:10. [PMID: 29774894 PMCID: PMC5945713 DOI: 10.1186/s41747-018-0041-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2017] [Accepted: 03/15/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) can palliate metastatic bone pain by periosteal neurolysis. We investigated the value of diffusion-weighted imaging (DWI) for monitoring soft tissue changes adjacent to bone during MR-guided HIFU. We evaluated the repeatability of the apparent diffusion coefficient (ADC) measurement, the temporal evolution of ADC change after sonication, and its relationship with thermal parameters. METHODS Ex-vivo experiments in lamb legs (n = 8) were performed on a Sonalleve MR-guided HIFU system. Baseline proton resonance frequency shift (PRFS) thermometry evaluated the accuracy of temperature measurements and tissue cooling times after exposure. PRFS acquired during sonication (n = 27) was used to estimate thermal dose volume and temperature. After repeat baseline measurements, DWI was assessed longitudinally and relative ADC changes were derived for heated regions. RESULTS Baseline PRFS was accurate to 1 °C and showed that tissues regained baseline temperatures within 5 min. Before sonication, coefficient of variation for repeat ADC measurements was 0.8%. After sonication, ADC increased in the muscle adjacent to the exposed periosteum, it was maximal 1-5 min after sonication, and it significantly differed between samples with persistent versus non-persistent ADC changes beyond 20 min. ADC increases at 20 min were stable for 2 h and correlated significantly with thermal parameters (ADC versus applied acoustic energy at 16-20 min: r = 0.77, p < 0.001). A 20% ADC increase resulted in clear macroscopic tissue damage. CONCLUSIONS Our preliminary results suggest that DWI can detect intra-procedural changes in ex-vivo muscle overlying the periosteum. This could be useful for studying the safety and efficacy of clinical MR-guided HIFU bone treatments.
Collapse
Affiliation(s)
- Sharon L. Giles
- MRI Unit, The Royal Marsden NHS Foundation Trust, London, UK
- Cancer Research UK Cancer Imaging Centre, Division of Imaging and Radiotherapy, The Institute of Cancer Research, London, UK
| | - Jessica M. Winfield
- MRI Unit, The Royal Marsden NHS Foundation Trust, London, UK
- Cancer Research UK Cancer Imaging Centre, Division of Imaging and Radiotherapy, The Institute of Cancer Research, London, UK
| | - David J. Collins
- Cancer Research UK Cancer Imaging Centre, Division of Imaging and Radiotherapy, The Institute of Cancer Research, London, UK
| | - Ian Rivens
- Therapeutic Ultrasound, Division of Imaging and Radiotherapy, The Institute of Cancer Research, London, UK
| | - John Civale
- Therapeutic Ultrasound, Division of Imaging and Radiotherapy, The Institute of Cancer Research, London, UK
| | - Gail R. ter Haar
- Therapeutic Ultrasound, Division of Imaging and Radiotherapy, The Institute of Cancer Research, London, UK
| | - Nandita M. deSouza
- Cancer Research UK Cancer Imaging Centre, Division of Imaging and Radiotherapy, The Institute of Cancer Research, London, UK
| |
Collapse
|
26
|
Elkhoury FF, Simopoulos DN, Marks LS. MR-guided biopsy and focal therapy: new options for prostate cancer management. Curr Opin Urol 2018; 28:93-101. [PMID: 29232269 PMCID: PMC7314431 DOI: 10.1097/mou.0000000000000471] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
PURPOSE OF REVIEW Options for prostate cancer management are rapidly expanding. The recent advent of MRI technology has led to guided prostate biopsies by radiologists working in-bore or by urologists using MR/US fusion technology. The resulting tumor visualization now provides the option of focal therapy. Currently available are highly directed energies - focused ultrasound (HIFU), cryotherapy, and laser - all offering the hope of curing prostate cancer with few side effects. RECENT FINDINGS MRI now enables visualization of many prostate cancers. MR/US fusion biopsy makes possible the targeted biopsy of suspicious lesions efficiently in the urology clinic. Several fusion devices are now commercially available. Focal therapy, a derivative of targeted biopsy, is reshaping the approach to treatment of some prostate cancers. Focal laser ablation, originally done in the MRI gantry (in-bore), promises to soon become feasible in a clinic setting (out-of-bore) under local anesthesia. Other focal therapy options, including HIFU and cryotherapy, are currently available. Herein are summarized outcomes data on focal therapy modalities. SUMMARY MRI-guided biopsy is optimizing prostate cancer diagnosis. Focal therapy, an outgrowth of guided biopsy, promises to become a well tolerated and effective approach to treating many men with prostate cancer while minimizing the risks of incontinence and impotence from radical treatment.
Collapse
Affiliation(s)
- Fuad F. Elkhoury
- UCLA Department of Urology, David Geffen School of Medicine, Wasserman Bldg, Suite 331, UCLA Medical Plaza, Los Angeles, CA 90095, Phone: 310-794-8659, Fax: 310-794-8653
| | - Demetrios N. Simopoulos
- UCLA Department of Urology, David Geffen School of Medicine, Wasserman Bldg, Suite 331, UCLA Medical Plaza, Los Angeles, CA 90095, Phone: 310-794-8659, Fax: 310-794-8653
| | - Leonard S. Marks
- UCLA Department of Urology, David Geffen School of Medicine, Wasserman Bldg, Suite 331, UCLA Medical Plaza, Los Angeles, CA 90095, Phone: 310-794-8659, Fax: 310-794-8653
| |
Collapse
|
27
|
Shin SH, Park SH, Kim SW, Kim M, Kim D. Fluorine MR Imaging Monitoring of Tumor Inflammation after High-Intensity Focused Ultrasound Ablation. Radiology 2018; 287:476-484. [PMID: 29369752 DOI: 10.1148/radiol.2017171603] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Purpose To investigate whether high-intensity focused ultrasound (HIFU)-induced macrophage infiltration could be longitudinally monitored with fluorine 19 (19F) magnetic resonance (MR) imaging in a quantitative manner. Materials and Methods BALB/c mice were subcutaneously inoculated with 4T1 cells and were separated into three groups: untreated mice (control, n = 9), HIFU-treated mice (HIFU, n = 9), and HIFU- and clodronate-treated mice (HIFU+Clod, n = 9). Immediately after HIFU treatment, all mice were intravenously given perfluorocarbon (PFC) emulsion. MR imaging examinations were performed 2, 4, 7, 10, and 14 days after HIFU treatment. Two-way repeated measures analysis of variance was used to analyze the changes in 19F signal over time and differences between groups. Histologic examinations were performed to confirm in vivo data. Results Fluorine 19 signals were detected at the rims of tumors and the peripheries of ablated lesions. Mean 19F signal in tumors was significantly higher in HIFU-treated mice than in control mice up to day 4 (0.82 ± 0.26 vs 0.42 ± 0.17, P < .001). Fluorine 19 signals were higher in the HIFU+Clod group than in the control group from day 4 (0.82 ± 0.23, P < .001) to day 14 (0.55 ± 0.16 vs 0.28 ± 0.06, P < .05). Histologic examination revealed macrophage infiltration around ablated lesions. Immunofluorescence staining confirmed PFC labeling of macrophages. Conclusion Fluorine 19 MR imaging can longitudinally capture and quantify HIFU-induced macrophage infiltration in preclinical tumor models. © RSNA, 2018 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Soo Hyun Shin
- From the Molecular Imaging Branch, Division of Convergence Technology, National Cancer Center, Research Building, Ilsanro-323, Ilsandong-gu, Goyang 10408, Korea
| | - Sang Hyun Park
- From the Molecular Imaging Branch, Division of Convergence Technology, National Cancer Center, Research Building, Ilsanro-323, Ilsandong-gu, Goyang 10408, Korea
| | - Seung Won Kim
- From the Molecular Imaging Branch, Division of Convergence Technology, National Cancer Center, Research Building, Ilsanro-323, Ilsandong-gu, Goyang 10408, Korea
| | - Minsun Kim
- From the Molecular Imaging Branch, Division of Convergence Technology, National Cancer Center, Research Building, Ilsanro-323, Ilsandong-gu, Goyang 10408, Korea
| | - Daehong Kim
- From the Molecular Imaging Branch, Division of Convergence Technology, National Cancer Center, Research Building, Ilsanro-323, Ilsandong-gu, Goyang 10408, Korea
| |
Collapse
|
28
|
STrategically Acquired Gradient Echo (STAGE) imaging, part I: Creating enhanced T1 contrast and standardized susceptibility weighted imaging and quantitative susceptibility mapping. Magn Reson Imaging 2017; 46:130-139. [PMID: 29056394 DOI: 10.1016/j.mri.2017.10.005] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2017] [Revised: 10/16/2017] [Accepted: 10/18/2017] [Indexed: 01/07/2023]
Abstract
PURPOSE To provide whole brain grey matter (GM) to white matter (WM) contrast enhanced T1W (T1WE) images, multi-echo quantitative susceptibility mapping (QSM), proton density (PD) weighted images, T1 maps, PD maps, susceptibility weighted imaging (SWI), and R2* maps with minimal misregistration in scanning times <5min. METHODS Strategically acquired gradient echo (STAGE) imaging includes two fully flow compensated double echo gradient echo acquisitions with a resolution of 0.67×1.33×2.0mm3 acquired in 5min for 64 slices. Ten subjects were recruited and scanned at 3 Tesla. The optimum pair of flip angles (6° and 24° with TR=25ms at 3T) were used for both T1 mapping with radio frequency (RF) transmit field correction and creating enhanced GM/WM contrast (the T1WE). The proposed T1WE image was created from a combination of the proton density weighted (6°, PDW) and T1W (24°) images and corrected for RF transmit field variations. Prior to the QSM calculation, a multi-echo phase unwrapping strategy was implemented using the unwrapped short echo to unwrap the longer echo to speed up computation. R2* maps were used to mask deep grey matter and veins during the iterative QSM calculation. A weighted-average sum of susceptibility maps was generated to increase the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR). RESULTS The proposed T1WE image has a significantly improved CNR both for WM to deep GM and WM to cortical GM compared to the acquired T1W image (the first echo of 24° scan) and the T1MPRAGE image. The weighted-average susceptibility maps have 80±26%, 55±22%, 108±33% SNR increases across the ten subjects compared to the single echo result of 17.5ms for the putamen, caudate nucleus, and globus pallidus, respectively. CONCLUSIONS STAGE imaging offers the potential to create a standardized brain imaging protocol providing four pieces of quantitative tissue property information and multiple types of qualitative information in just 5min.
Collapse
|
29
|
MacLellan CJ, Fuentes D, Prabhu S, Rao G, Weinberg JS, Hazle JD, Stafford RJ. A methodology for thermal dose model parameter development using perioperative MRI. Int J Hyperthermia 2017; 34:687-696. [PMID: 28830311 DOI: 10.1080/02656736.2017.1363418] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Post-treatment imaging is the principal method for evaluating thermal lesions following image-guided thermal ablation procedures. While real-time temperature feedback using magnetic resonance temperature imaging (MRTI) is a complementary tool that can be used to optimise lesion size throughout the procedure, a thermal dose model is needed to convert temperature-time histories to estimates of thermal damage. However, existing models rely on empirical parameters derived from laboratory experiments that are not direct indicators of post-treatment radiologic appearance. In this work, we investigate a technique that uses perioperative MR data to find novel thermal dose model parameters that are tailored to the appearance of the thermal lesion on post-treatment contrast-enhanced imaging. Perioperative MR data were analysed for five patients receiving magnetic resonance-guided laser-induced thermal therapy (MRgLITT) for brain metastases. The characteristic enhancing ring was manually segmented on post-treatment T1-weighted imaging and registered into the MRTI geometry. Post-treatment appearance was modelled using a coupled Arrhenius-logistic model and non-linear optimisation techniques were used to find the maximum-likelihood kinetic parameters and dose thresholds that characterise the inner and outer boundary of the enhancing ring. The parameter values and thresholds were consistent with previous investigations, while the average difference between the predicted and segmented boundaries was on the order of one pixel (1 mm). The areas predicted using the optimised model parameters were also within 1 mm of those predicted by clinically utilised dose models. This technique makes clinically acquired data available for investigating new thermal dose model parameters driven by clinically relevant endpoints.
Collapse
Affiliation(s)
- Christopher J MacLellan
- a Department of Imaging Physics , The University of Texas MD Anderson Cancer Center , Houston , TX , USA.,b The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| | - David Fuentes
- a Department of Imaging Physics , The University of Texas MD Anderson Cancer Center , Houston , TX , USA.,b The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| | - Sujit Prabhu
- c Department of Neurosurgery , The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| | - Ganesh Rao
- c Department of Neurosurgery , The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| | - Jeffrey S Weinberg
- c Department of Neurosurgery , The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| | - John D Hazle
- a Department of Imaging Physics , The University of Texas MD Anderson Cancer Center , Houston , TX , USA.,b The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| | - R Jason Stafford
- a Department of Imaging Physics , The University of Texas MD Anderson Cancer Center , Houston , TX , USA.,b The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| |
Collapse
|
30
|
Kothapalli SVVN, Altman MB, Partanen A, Wan L, Gach HM, Straube W, Hallahan DE, Chen H. Acoustic field characterization of a clinical magnetic resonance-guided high-intensity focused ultrasound system inside the magnet bore. Med Phys 2017. [PMID: 28626862 DOI: 10.1002/mp.12412] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
PURPOSE With the expanding clinical application of magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU), acoustic field characterization of MR-HIFU systems is needed for facilitating regulatory approval and ensuring consistent and safe power output of HIFU transducers. However, the established acoustic field measurement techniques typically use equipment that cannot be used in a magnetic resonance imaging (MRI) suite, thus posing a challenge to the development and execution of HIFU acoustic field characterization techniques. In this study, we developed and characterized a technique for HIFU acoustic field calibration within the MRI magnet bore, and validated the technique with standard hydrophone measurements outside of the MRI suite. METHODS A clinical Philips MR-HIFU system (Sonalleve V2, Philips, Vantaa, Finland) was used to assess the proposed technique. A fiber-optic hydrophone with a long fiber was inserted through a 24-gauge angiocatheter and fixed inside a water tank that was placed on the HIFU patient table above the acoustic window. The long fiber allowed the hydrophone control unit to be placed outside of the magnet room. The location of the fiber tip was traced on MR images, and the HIFU focal point was positioned at the fiber tip using the MR-HIFU therapy planning software. To perform acoustic field mapping inside the magnet, the HIFU focus was positioned relative to the fiber tip using an MRI-compatible 5-axis robotic transducer positioning system embedded in the HIFU patient table. To perform validation measurements of the acoustic fields, the HIFU table was moved out of the MRI suite, and a standard laboratory hydrophone measurement setup was used to perform acoustic field measurements outside the magnetic field. RESULTS The pressure field scans along and across the acoustic beam path obtained inside the MRI bore were in good agreement with those obtained outside of the MRI suite. At the HIFU focus with varying nominal acoustic powers of 10-500 W, the peak positive pressure and peak negative pressure measured inside the magnet bore were 3.87-68.67 MPa and 3.56-12.06 MPa, respectively, while outside the MRI suite the corresponding pressures were 3.27-67.32 MPa and 3.06-12.39 MPa, respectively. There was no statistically significant difference (P > 0.05) between measurements inside the magnet bore and outside the MRI suite for the p+ and p- at any acoustic power level. The spatial-peak pulse-average intensities (ISPPA ) for these powers were 312-17816 W/cm2 and 220-15698 W/cm2 for measurements inside and outside the magnet room, respectively. In addition, when the scanning step size of the HIFU focus was increased from 100 μm to 500 μm, the execution time for scanning a 4 × 4 mm2 area decreased from 210 min to 10 min, the peak positive pressure decreased by 14%, the peak negative pressure decreased by 5%, and the lateral full width at half maximum dimension of pressure profiles increased from 1.15 mm to 1.55 mm. CONCLUSIONS The proposed hydrophone measurement technique offers a convenient and reliable method for characterizing the acoustic fields of clinical MR-HIFU systems inside the magnet bore. The technique was validated for use by measurements outside the MRI suite using a standard hydrophone calibration technique. This technique can be a useful tool in MR-HIFU quality assurance and acoustic field assessment.
Collapse
Affiliation(s)
- Satya V V N Kothapalli
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO, 63130, USA
| | - Michael B Altman
- Department of Radiation Oncology, Washington University in St. Louis, Saint Louis, MO, 63108, USA
| | - Ari Partanen
- Clinical Science MR Therapy, Philips, Andover, MA, 01810, USA
| | - Leighton Wan
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO, 63130, USA
| | - H Michael Gach
- Departments of Radiation Oncology and Radiology, Washington University in St. Louis, Saint Louis, MO, 63108, USA
| | - William Straube
- Department of Radiation Oncology, Washington University in St. Louis, Saint Louis, MO, 63108, USA
| | - Dennis E Hallahan
- Department of Radiation Oncology, Washington University in St. Louis, Saint Louis, MO, 63108, USA
| | - Hong Chen
- Departments of Biomedical Engineering and Radiation Oncology, Washington University in St. Louis, Saint Louis, MO, 63130, USA
| |
Collapse
|
31
|
Contrast-enhanced ultrasound evaluation of pancreatic cancer xenografts in nude mice after irradiation with sub-threshold focused ultrasound for tumor ablation. Oncotarget 2017; 8:37584-37593. [PMID: 28402267 PMCID: PMC5514932 DOI: 10.18632/oncotarget.16621] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2017] [Accepted: 03/09/2017] [Indexed: 01/15/2023] Open
Abstract
We evaluated the efficacy of contrast-enhanced ultrasound for assessing tumors after irradiation with sub-threshold focused ultrasound (FUS) ablation in pancreatic cancer xenografts in nude mice. Thirty tumor-bearing nude mice were divided into three groups: Group A received sham irradiation, Group B received a moderate-acoustic energy dose (sub-threshold), and Group C received a high-acoustic energy dose. In Group B, B-mode ultrasound (US), color Doppler US, and dynamic contrast-enhanced ultrasound (DCE-US) studies were conducted before and after irradiation. After irradiation, tumor growth was inhibited in Group B, and the tumors shrank in Group C. In Group A, the tumor sizes were unchanged. In Group B, contrast-enhanced ultrasound (CEUS) images showed a rapid rush of contrast agent into and out of tumors before irradiation. After irradiation, CEUS revealed contrast agent perfusion only at the tumor periphery and irregular, un-perfused volumes of contrast agent within the tumors. DCE-US perfusion parameters, including peak intensity (PI) and area under the curve (AUC), had decreased 24 hours after irradiation. PI and AUC were increased 48 hours and 2weeks after irradiation. Time to peak (TP) and sharpness were increased 24 hours after irradiation. TP decreased at 48 hours and 2 weeks after irradiation. CEUS is thus an effective method for early evaluation after irradiation with sub-threshold FUS.
Collapse
|
32
|
Kuroda K. MR techniques for guiding high-intensity focused ultrasound (HIFU) treatments. J Magn Reson Imaging 2017; 47:316-331. [PMID: 28580706 DOI: 10.1002/jmri.25770] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Accepted: 05/02/2017] [Indexed: 12/17/2022] Open
Abstract
To make full use of the ability of magnetic resonance (MR) to guide high-intensity focused ultrasound (HIFU) treatment, effort has been made to improve techniques for thermometry, motion tracking, and sound beam visualization. For monitoring rapid temperature elevation with proton resonance frequency (PRF) shift, data acquisition and processing can be accelerated with parallel imaging and/or sparse sampling in conjunction with appropriate signal processing methods. Thermometry should be robust against tissue motion, motion-induced magnetic field variation, and susceptibility change. Thus, multibaseline, referenceless, or hybrid techniques have become important. In cases with adipose or bony tissues, for which PRF shift cannot be used, thermometry with relaxation times or signal intensity may be utilized. Motion tracking is crucial not only for thermometry but also for targeting the focus of an ultrasound in moving organs such as the liver, kidney, or heart. Various techniques for motion tracking, such as those based on an anatomical image atlas with optical-flow displacement detection, a navigator echo to seize the diaphragm position, and/or rapid imaging to track vessel positions, have been proposed. Techniques for avoiding the ribcage and near-field heating have also been examined. MR acoustic radiation force imaging (MR-ARFI) is an alternative to thermometry that can identify the location and shape of the focal spot and sound beam path. This technique could be useful for treating heterogeneous tissue regions or performing transcranial therapy. All of these developments, which will be discussed further in this review, expand the applicability of HIFU treatments to a variety of clinical targets while maintaining safety and precision. LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 4 J. Magn. Reson. Imaging 2018;47:316-331.
Collapse
Affiliation(s)
- Kagayaki Kuroda
- Department of Human and Information Science, School of Information Science and Technology, Tokai University, Hiratsuka, Kanagawa, Japan.,Center for Frontier Medical Engineering, Chiba University, Inage, Chiba, Japan
| |
Collapse
|
33
|
Thermal combination therapies for local drug delivery by magnetic resonance-guided high-intensity focused ultrasound. Proc Natl Acad Sci U S A 2017; 114:E4802-E4811. [PMID: 28566498 DOI: 10.1073/pnas.1700790114] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Several thermal-therapy strategies such as thermal ablation, hyperthermia-triggered drug delivery from temperature-sensitive liposomes (TSLs), and combinations of the above were investigated in a rhabdomyosarcoma rat tumor model (n = 113). Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) was used as a noninvasive heating device with precise temperature control for image-guided drug delivery. For the latter, TSLs were prepared, coencapsulating doxorubicin (dox) and [Gd(HPDO3A)(H2O)], and injected in tumor-bearing rats before MR-HIFU treatment. Four treatment groups were defined: hyperthermia, ablation, hyperthermia followed by ablation, or no HIFU. The intratumoral TSL and dox distribution were analyzed by single-photon emission computed tomography (SPECT)/computed tomography (CT), autoradiography, and fluorescence microscopy. Dox biodistribution was quantified and compared with that of nonliposomal dox. Finally, the treatment efficacy of all heating strategies plus additional control groups (saline, free dox, and Caelyx) was assessed by tumor growth measurements. All HIFU heating strategies combined with TSLs resulted in cellular uptake of dox deep into the interstitial space and a significant increase of tumor drug concentrations compared with a treatment with free dox. Ablation after TSL injection showed [Gd(HPDO3A)(H2O)] and dox release along the tumor rim, mirroring the TSL distribution pattern. Hyperthermia either as standalone treatment or before ablation ensured homogeneous TSL, [Gd(HPDO3A)(H2O)], and dox delivery across the tumor. The combination of hyperthermia-triggered drug delivery followed by ablation showed the best therapeutic outcome compared with all other treatment groups due to direct induction of thermal necrosis in the tumor core and efficient drug delivery to the tumor rim.
Collapse
|
34
|
Staruch RM, Nofiele J, Walker J, Bing C, Madhuranthakam AJ, Bailey A, Kim YS, Chhabra A, Burns D, Chopra R. Assessment of acute thermal damage volumes in muscle using magnetization-prepared 3D T 2 -weighted imaging following MRI-guided high-intensity focused ultrasound therapy. J Magn Reson Imaging 2017; 46:354-364. [PMID: 28067975 DOI: 10.1002/jmri.25605] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2016] [Accepted: 12/05/2016] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To evaluate magnetization-prepared 3D T2 -weighted magnetic resonance imaging (MRI) measurements of acute tissue changes produced during ablative MR high-intensity focused ultrasound (MR-HIFU) exposures. MATERIALS AND METHODS A clinical MR-HIFU system (3T) was used to generate thermal lesions (n = 24) in the skeletal muscles of three pigs. T1 -weighted, 2D T2 -weighted, and magnetization-prepared 3D T2 -weighted sequences were acquired before and after therapy to evaluate tissue changes following ablation. Tissues were harvested shortly after imaging, fixed in formalin, and gross-sectioned. Select lesions were processed into whole-mount sections. Lesion dimensions for each imaging sequence (length, width) and for gross sections (diameter of lesion core and rim) were assessed by three physicists. Contrast-to-background ratio between lesions and surrounding muscle was compared. RESULTS Lesion dimensions on T1 and 2D T2 -weighted imaging sequences were well correlated (R2 ∼0.7). The contrast-to-background ratio between lesion and surrounding muscle was 7.4 ± 2.4 for the magnetization-prepared sequence versus 1.7 ± 0.5 for a conventional 2D T2 -weighted acquisition, and 7.0 ± 2.9 for a contrast-enhanced T1 -weighted sequence. Compared with diameter measured on gross pathology, all imaging sequences overestimated the lesion core by 22-33%, and underestimated the lesion rim by 6-13%. CONCLUSION After MR-HIFU exposures, measurements of the acute thermal damage patterns in muscle using a magnetization-prepared 3D T2 -weighted imaging sequence correlate with 2D T2 -weighted and contrast-enhanced T1 -weighted imaging, and all agree well with histology. The magnetization-prepared sequence offers positive tissue contrast and does not require IV contrast agents, and may provide a noninvasive imaging evaluation of the region of acute thermal injury at multiple times during HIFU procedures. LEVEL OF EVIDENCE 1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:354-364.
Collapse
Affiliation(s)
- Robert M Staruch
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA.,Clinical Sites Research Program, Philips Research North America, Cambridge, Massachusetts, USA
| | - Joris Nofiele
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Jamie Walker
- Department of Pathology, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Chenchen Bing
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Ananth J Madhuranthakam
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA.,Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas, USA
| | - April Bailey
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Young-Sun Kim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University, Seoul, Korea
| | - Avneesh Chhabra
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Dennis Burns
- Department of Pathology, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Rajiv Chopra
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA.,Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas, USA
| |
Collapse
|
35
|
Shin SH, Park EJ, Min C, Choi SI, Jeon S, Kim YH, Kim D. Tracking Perfluorocarbon Nanoemulsion Delivery by 19F MRI for Precise High Intensity Focused Ultrasound Tumor Ablation. Am J Cancer Res 2017; 7:562-572. [PMID: 28255351 PMCID: PMC5327634 DOI: 10.7150/thno.16895] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2016] [Accepted: 11/10/2016] [Indexed: 12/22/2022] Open
Abstract
Perfluorocarbon nanoemulsions (PFCNEs) have recently been undergoing rigorous study to investigate their ability to improve the therapeutic efficacy of tumor ablation by high intensity focused ultrasound (HIFU). For precise control of PFCNE delivery and thermal ablation, their accumulation and distribution in a tumor should be quantitatively analyzed. Here, we used fluorine-19 (19F) magnetic resonance imaging (MRI) to quantitatively track PFCNE accumulation in a tumor, and analyzed how intra-tumoral PFCNE quantities affect the therapeutic efficacy of HIFU treatment. Ablation outcomes were assessed by intra-voxel incoherent motion analysis and bioluminescent imaging up to 14 days after the procedure. Assessment of PFCNE delivery and treatment outcomes showed that 2-3 mg/mL of PFCNE in a tumor produces the largest ablation volume under the same HIFU insonation conditions. Histology showed varying degrees of necrosis depending on the amount of PFCNE delivered. 19F MRI promises to be a valuable platform for precisely guiding PFCNE-enhanced HIFU ablation of tumors.
Collapse
|
36
|
Gillies MJ, Lyon PC, Wu F, Leslie T, Chung DY, Gleeson F, Cranston D, Bojanic S. High-intensity focused ultrasonic ablation of sacral chordoma is feasible: a series of four cases and details of a national clinical trial. Br J Neurosurg 2016; 31:446-451. [PMID: 27936948 DOI: 10.1080/02688697.2016.1267330] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
High-intensity focused ultrasound describes the use of high-intensity focused ultrasound (HIFU) to ablate tumours without requiring an incision or other invasive procedure. This technique has been trialled on a range of tumours including uterine fibroids, prostate, liver and renal cancer. We describe our experience of using HIFU to ablate sacral chordoma in four patients with advanced tumours. Patients were treated under general anaesthetic or sedation using an ultrasound-guided HIFU device. HIFU therapy was associated with a reduction in tumour volume over time in three patients for whom follow up scans were available. Tumour necrosis was reliably demonstrated in two of the three patients. We have established a national trial to assess if HIFU may improve long-term outcome from sacral chordoma, details are given.
Collapse
Affiliation(s)
- Martin J Gillies
- a Department of Neurosurgery , West Wing, John Radcliffe Hospital , Oxford , UK.,b Nuffield Department of Surgical Sciences , University of Oxford , Oxford , UK
| | - Paul C Lyon
- b Nuffield Department of Surgical Sciences , University of Oxford , Oxford , UK
| | - Feng Wu
- b Nuffield Department of Surgical Sciences , University of Oxford , Oxford , UK.,c HIFU Unit , Churchill Hospital , Headington, Oxford , UK
| | - Tom Leslie
- b Nuffield Department of Surgical Sciences , University of Oxford , Oxford , UK
| | - Daniel Y Chung
- d Department of Radiology , Churchill Hospital , Oxford , UK
| | - Fergus Gleeson
- d Department of Radiology , Churchill Hospital , Oxford , UK
| | - David Cranston
- b Nuffield Department of Surgical Sciences , University of Oxford , Oxford , UK.,c HIFU Unit , Churchill Hospital , Headington, Oxford , UK
| | - Stana Bojanic
- a Department of Neurosurgery , West Wing, John Radcliffe Hospital , Oxford , UK
| |
Collapse
|
37
|
Schreurs TJL, Hectors SJ, Jacobs I, Grüll H, Nicolay K, Strijkers GJ. Quantitative Multi-Parametric Magnetic Resonance Imaging of Tumor Response to Photodynamic Therapy. PLoS One 2016; 11:e0165759. [PMID: 27820832 PMCID: PMC5098733 DOI: 10.1371/journal.pone.0165759] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2016] [Accepted: 10/17/2016] [Indexed: 12/17/2022] Open
Abstract
Objective The aim of this study was to characterize response to photodynamic therapy (PDT) in a mouse cancer model using a multi-parametric quantitative MRI protocol and to identify MR parameters as potential biomarkers for early assessment of treatment outcome. Methods CT26.WT colon carcinoma tumors were grown subcutaneously in the hind limb of BALB/c mice. Therapy consisted of intravenous injection of the photosensitizer Bremachlorin, followed by 10 min laser illumination (200 mW/cm2) of the tumor 6 h post injection. MRI at 7 T was performed at baseline, directly after PDT, as well as at 24 h, and 72 h. Tumor relaxation time constants (T1 and T2) and apparent diffusion coefficient (ADC) were quantified at each time point. Additionally, Gd-DOTA dynamic contrast-enhanced (DCE) MRI was performed to estimate transfer constants (Ktrans) and volume fractions of the extravascular extracellular space (ve) using standard Tofts-Kermode tracer kinetic modeling. At the end of the experiment, tumor viability was characterized by histology using NADH-diaphorase staining. Results The therapy induced extensive cell death in the tumor and resulted in significant reduction in tumor growth, as compared to untreated controls. Tumor T1 and T2 relaxation times remained unchanged up to 24 h, but decreased at 72 h after treatment. Tumor ADC values significantly increased at 24 h and 72 h. DCE-MRI derived tracer kinetic parameters displayed an early response to the treatment. Directly after PDT complete vascular shutdown was observed in large parts of the tumors and reduced uptake (decreased Ktrans) in remaining tumor tissue. At 24 h, contrast uptake in most tumors was essentially absent. Out of 5 animals that were monitored for 2 weeks after treatment, 3 had tumor recurrence, in locations that showed strong contrast uptake at 72 h. Conclusion DCE-MRI is an effective tool for visualization of vascular effects directly after PDT. Endogenous contrast parameters T1, T2, and ADC, measured at 24 to 72 h after PDT, are also potential biomarkers for evaluation of therapy outcome.
Collapse
Affiliation(s)
- Tom J L Schreurs
- Biomedical NMR, Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Stefanie J Hectors
- Department of Radiology, Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, New York, United States of America
| | - Igor Jacobs
- Biomedical NMR, Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Holger Grüll
- Biomedical NMR, Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.,Department of Oncology Solutions, Philips Research, Eindhoven, The Netherlands
| | - Klaas Nicolay
- Biomedical NMR, Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Gustav J Strijkers
- Biomedical Engineering and Physics, Academic Medical Center, Amsterdam, The Netherlands
| |
Collapse
|
38
|
Perera M, Krishnananthan N, Lindner U, Lawrentschuk N. An update on focal therapy for prostate cancer. Nat Rev Urol 2016; 13:641-653. [DOI: 10.1038/nrurol.2016.177] [Citation(s) in RCA: 70] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
39
|
Krug R, Do L, Rieke V, Wilson MW, Saeed M. Evaluation of MRI protocols for the assessment of lumbar facet joints after MR-guided focused ultrasound treatment. J Ther Ultrasound 2016; 4:14. [PMID: 27054038 PMCID: PMC4822243 DOI: 10.1186/s40349-016-0057-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2016] [Accepted: 03/23/2016] [Indexed: 01/20/2023] Open
Abstract
BACKGROUND MR-guided focused ultrasound (MRgFUS) might be a very safe and effective minimally invasive technique to treat facet joint pain caused by arthritis and other degenerative changes. However, there are still safety concerns for this treatment and challenges regarding MR imaging and temperature mapping due to susceptibility effects between the bone and soft tissue near the joint, which has resulted in poor MR image quality. The goal of this research was to evaluate multiple magnetic resonance imaging (MRI) pulse sequences for characterizing ablated lumbar facet joint lesions created by high-intensity focused ultrasound (FUS) and compare the findings to histological tissue assessment. In particular, we investigated the use of T2-weighted MRI to assess treatment effects without contrast administration. METHODS An IACUC approved study (n = 6 pigs) was performed using a 3T widebore MRI system equipped with an MRgFUS system. Facet joints of the lumbar vertebra were ablated using 1-MHz frequency and multiple sonication energies (300-800 J). In addition to T2-weighted MRI for treatment planning, T1-, T2-, and T2*-weighted and perfusion MRI sequences were applied. Signal intensity ratios of the lesions were determined. Histopathology was used to characterize cellular changes. RESULTS Ablation of the facet joint, using MRgFUS, was successful in all animals. T2-weighted images showed high signal intensity in the edematous facet joint and adjacent muscle, while delayed contrast-enhanced T1-weighted images showed an enhanced ring surrounding the target volume. T2*-weighted GRE images revealed inconsistent lesion visualization. Histopathology confirmed the presence of cellular coagulation (shrinkage), extracellular expansion (edema), and hemorrhage in the bone marrow. CONCLUSIONS MRgFUS provided sufficient precision and image quality for visualization and characterization of ablated facet joints directly after ablation. MRI may help in monitoring the efficacy of FUS ablation without contrast after treating patients with back pain.
Collapse
Affiliation(s)
- Roland Krug
- Department of Radiology and Biomedical Imaging, School of Medicine, University of California San Francisco, 185 Berry Street, Suite 350, Campus Box 0946, San Francisco, CA 94107-5705 USA
| | - Loi Do
- Department of Radiology and Biomedical Imaging, School of Medicine, University of California San Francisco, 185 Berry Street, Suite 350, Campus Box 0946, San Francisco, CA 94107-5705 USA
| | - Viola Rieke
- Department of Radiology and Biomedical Imaging, School of Medicine, University of California San Francisco, 185 Berry Street, Suite 350, Campus Box 0946, San Francisco, CA 94107-5705 USA
| | - Mark W Wilson
- Department of Radiology and Biomedical Imaging, School of Medicine, University of California San Francisco, 185 Berry Street, Suite 350, Campus Box 0946, San Francisco, CA 94107-5705 USA
| | - Maythem Saeed
- Department of Radiology and Biomedical Imaging, School of Medicine, University of California San Francisco, 185 Berry Street, Suite 350, Campus Box 0946, San Francisco, CA 94107-5705 USA
| |
Collapse
|