1
|
Singh M, Mahmud SZ, Yedavalli V, Zhou J, Kamson DO, van Zijl P, Heo H. Learning-based motion artifact correction in the Z-spectral domain for chemical exchange saturation transfer MRI. Magn Reson Med 2025; 94:331-345. [PMID: 39834104 PMCID: PMC12021334 DOI: 10.1002/mrm.30440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 12/23/2024] [Accepted: 01/05/2025] [Indexed: 01/22/2025]
Abstract
PURPOSE To develop and evaluate a physics-driven, saturation contrast-aware, deep-learning-based framework for motion artifact correction in CEST MRI. METHODS A neural network was designed to correct motion artifacts directly from a Z-spectrum frequency (Ω) domain rather than an image spatial domain. Motion artifacts were simulated by modeling 3D rigid-body motion and readout-related motion during k-space sampling. A saturation-contrast-specific loss function was added to preserve amide proton transfer (APT) contrast, as well as enforce image alignment between motion-corrected and ground-truth images. The proposed neural network was evaluated on simulation data and demonstrated in healthy volunteers and brain tumor patients. RESULTS The experimental results showed the effectiveness of motion artifact correction in the Z-spectrum frequency domain (MOCOΩ) compared to in the image spatial domain. In addition, a temporal convolution applied to a dynamic saturation image series was able to leverage motion artifacts to improve reconstruction results as a denoising process. The MOCOΩ outperformed existing techniques for motion correction in terms of image quality and computational efficiency. At 3 T, human experiments showed that the root mean squared error (RMSE) of APT images decreased from 4.7% to 2.1% at 1 μT and from 6.2% to 3.5% at 1.5 μT in case of "moderate" motion and from 8.7% to 2.8% at 1 μT and from 12.7% to 4.5% at 1.5 μT in case of "severe" motion, after motion artifact correction. CONCLUSION The MOCOΩ could effectively correct motion artifacts in CEST MRI without compromising saturation transfer contrast.
Collapse
Affiliation(s)
- Munendra Singh
- Department of RadiologyJohns Hopkins University
BaltimoreMarylandUSA
| | - Sultan Z. Mahmud
- Department of RadiologyJohns Hopkins University
BaltimoreMarylandUSA
| | - Vivek Yedavalli
- Department of RadiologyJohns Hopkins University
BaltimoreMarylandUSA
| | - Jinyuan Zhou
- Department of RadiologyJohns Hopkins University
BaltimoreMarylandUSA
| | - David Olayinka Kamson
- Department of OncologyJohns Hopkins UniversityBaltimoreMarylandUSA
- Department of NeurologyJohns Hopkins UniversityBaltimoreMarylandUSA
| | - Peter van Zijl
- Department of RadiologyJohns Hopkins University
BaltimoreMarylandUSA
- F.M. Kirby Research Center for Functional Brain ImagingKennedy Krieger InstituteBaltimoreMarylandUSA
| | - Hye‐Young Heo
- Department of RadiologyJohns Hopkins University
BaltimoreMarylandUSA
- F.M. Kirby Research Center for Functional Brain ImagingKennedy Krieger InstituteBaltimoreMarylandUSA
| |
Collapse
|
2
|
Zhao Y, Afzal A, Zu Z. Asymmetry analysis of nuclear Overhauser enhancement effect at -1.6 ppm in ischemic stroke. Med Phys 2025. [PMID: 39933960 DOI: 10.1002/mp.17677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2024] [Revised: 12/14/2024] [Accepted: 01/13/2025] [Indexed: 02/13/2025] Open
Abstract
BACKGROUND The nuclear Overhauser enhancement (NOE)-mediated saturation transfer effect at -1.6 ppm, termed NOE(-1.6 ppm), has demonstrated potential for detecting ischemic stroke. However, the quantification of the NOE(-1.6 ppm) effect usually relies on a multiple-pool Lorentzian fit method, which necessitates a time-consuming acquisition of the entire chemical exchange saturation transfer (CEST) Z-spectrum with high-frequency resolution, thus hindering its clinical applications. PURPOSE This study aims to assess the feasibility of employing asymmetry analysis, a rapid CEST data acquisition and analysis method, for quantifying the NOE(-1.6 ppm) effect in an animal model of ischemic stroke. METHODS We examined potential contaminations from guanidinium/amine CEST, NOE(-3.5 ppm), and asymmetric magnetization transfer (MT) effects, which could reduce the specificity of the asymmetry analysis of NOE(-1.6 ppm). First, a Lorentzian difference (LD) analysis was used to mitigate direct water saturation and MT effects, providing separate estimations of the contributions from the guanidinium/amine CEST and NOE effects. Then, the asymmetry analysis of the LD fitted spectrum was compared with the asymmetry analysis of the raw CEST Z-spectrum to evaluate the contribution of the asymmetric MT effect at -1.6 ppm. RESULTS Results show that the variations of the LD quantified NOE(-1.6 ppm) in stroke lesions are much greater than that of the CEST signals at +1.6 ppm and NOE(-3.5 ppm), suggesting that NOE(-1.6 ppm) has a dominating contribution to the asymmetry analysis at -1.6 ppm compared with the guanidinium/amine CEST and NOE(-3.5 ppm) in ischemic stroke. The NOE(-1.6 ppm) variations in the asymmetry analysis of the raw CEST Z-spectrum are close to those in the asymmetry analysis of the LD fitted spectrum, revealing that the NOE(-1.6 ppm) dominates over the asymmetric MT effects. CONCLUSION Our study demonstrates that the asymmetry analysis can quantify the NOE(-1.6 ppm) contrast in ischemic stroke with high specificity, thus presenting a viable alternative for rapid mapping of ischemic stroke.
Collapse
Affiliation(s)
- Yu Zhao
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, USA
- Department of Radiology, and Functional and Molecular Imaging Key Laboratory of Sichuan Province, West China Hospital of Sichuan University, Chengdu, China
| | - Aqeela Afzal
- Department of Neurological Surgery, Vanderbilt University Medical Center, Nashville, USA
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, USA
| |
Collapse
|
3
|
Chen W, Chen Z, Ma L, Wang Y, Song X. Rapid and quantitative CEST-MRI sequence using water presaturation. Magn Reson Med 2025; 93:730-740. [PMID: 39385344 DOI: 10.1002/mrm.30309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 08/07/2024] [Accepted: 09/03/2024] [Indexed: 10/12/2024]
Abstract
PURPOSE Despite the significant potential for in vivo metabolic imaging in preclinical and clinical applications, CEST MRI suffers from long scan time and inaccurate quantification. This study aims to suppress the contaminations among signals under different frequencies, which could shorten the TR and thereby facilitate CEST imaging acceleration and quantification. METHODS A novel sequence is proposed by applying a water-presaturation (WPS) module at the beginning of each TR. WPS CEST quickly knocks down the residual signal from previous TRs so that the magnetization of all TRs recovers from zero, which aligns well with the formula of quasi-steady-state theorem and enables accurate quantification within shorter TR. WPS CEST was assessed by simulations, creatine phantom, and healthy human brain scans at 3 T. RESULTS In simulation and phantom experiment, WPS CEST allows accurate estimation of exchange rate (ksw) using omega plot and using shorter delay time (Td) and saturation time (Ts) (e.g., 1 s/1 s) compared with the conventional CEST. Simulations further showed that WPS CEST could obtain consistent spin-lock relaxation (R1ρ) values over varied Tds and Tss. Six human scans indicated that R1ρ collected from conventional sequences showed significant differences between two groups with Td and Ts of (1 s/1 s) and (2 s/2 s) (amide: 1.721 ± 0.051 s-1 vs. 1.622 ± 0.050 s-1, p = 0.001; nuclear Overhauser enhancement: 1.792 ± 0.046 s-1 vs. 1.687 ± 0.053 s-1, p = 0.004), whereas WPS CEST scans using these 2 Td/Ts values obtained the same mean R1ρ (amide: 1.616 ± 0.053 s-1 vs. 1.616 ± 0.048 s-1, p = 0.862; nuclear Overhauser enhancement: 1.688 ± 0.064 s-1 vs. 1.684 ± 0.054 s-1, p = 0.544). CONCLUSION WPS CEST demonstrated accurate quantitation within shorter TR compared with conventional sequences, and thereby may allow rapid quantitative CEST scans in various situations.
Collapse
Affiliation(s)
- Wenxuan Chen
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, China
| | - Zhensen Chen
- Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China
- Ministry of Education, Key Laboratory of Computational Neuroscience and Brain-Inspired Intelligence (Fudan University), Shanghai, China
| | - Lele Ma
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, China
| | - Yi Wang
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, China
- Public Health Science and Engineering College, Tianjin University of Traditional Chinese Medicine, Tianjin, China
| | - Xiaolei Song
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, China
| |
Collapse
|
4
|
Sun PZ. Physics-guided multi-dimensional scan optimization and quasi-steady-state reconstruction to enhance CEST MRI sensitivity efficiency and quantification accuracy. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2025; 370:107821. [PMID: 39689390 PMCID: PMC11725439 DOI: 10.1016/j.jmr.2024.107821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2024] [Revised: 11/20/2024] [Accepted: 12/07/2024] [Indexed: 12/19/2024]
Abstract
Chemical exchange saturation transfer (CEST) MRI has become increasingly utilized for detecting dilute labile protons and characterizing microenvironment properties. However, the CEST MRI effect is only a few percent, and there is a need for a systematic approach to optimize scan parameters for sensitive and accurate CEST quantification. We propose multi-dimensional adjustments of key parameters such as the repetition time (TR) and RF duty cycle to optimize CEST MRI sensitivity per unit of time and utilization of quasi-steady-state (QUASS) reconstruction to recover the full CEST effect during postprocessing. Our work herein derived the CEST effect based on the generalized spin-lock CEST model and determined the interdependency of the optimal RF duty cycle and TR, showing the optimal TR decreases with the RF duty cycle but plateaus beyond 60-80 %. The accuracy of the solution was validated with both numerical simulations and CEST MRI experiments on a dual pH creatine gel phantom. The desired equilibrium CEST effect was further reconstructed with the QUASS algorithm from the optimized CEST MRI scan. In summary, our study establishes a workflow for CEST MRI scan optimization and postprocessing analysis, providing a framework to boost both the sensitivity of CEST MRI scans and the accuracy of CEST quantification. This approach holds promise for future in vivo validation and translation.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Non-Human-Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, GA, United States; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States; Winship Cancer Institute, Emory University School of Medicine, Atlanta, GA, United States.
| |
Collapse
|
5
|
Chung JJ, Kim H, Ji Y, Lu D, Zhou IY, Sun PZ. Improving standardization and accuracy of in vivo omega plot exchange parameter determination using rotating-frame model-based fitting of quasi-steady-state Z-spectra. Magn Reson Med 2025; 93:151-165. [PMID: 39221563 PMCID: PMC11518644 DOI: 10.1002/mrm.30259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Revised: 07/31/2024] [Accepted: 08/01/2024] [Indexed: 09/04/2024]
Abstract
PURPOSE Although Ω-plot-driven quantification of in vivo amide exchange properties has been demonstrated, differences in scan parameters may complicate the fidelity of determination. This work systematically evaluated the use of quasi-steady-state (QUASS) Z-spectra reconstruction to standardize in vivo amide exchange quantification across acquisition conditions and further determined it in vivo. METHODS Simulation and in vivo rodent brain chemical exchange saturation transfer (CEST) data at 4.7 T were fit with and without QUASS reconstruction using both multi-Lorentzian and model-based fitting approaches. pH modulation was accomplished both in simulation and in vivo by inducing global ischemia via cardiac arrest. Amide parameters were determined via Ω-plots and compared across methods. RESULTS Simulation showed that Ω-plots using multi-Lorentzian fitting could underestimate the exchange rate, with error increasing as conditions diverged from the steady state. In comparison, model-based fitting using QUASS estimated the same exchange rate within 2%. These results aligned with in vivo findings where multi-Lorentzian fitting of native Z-spectra resulted in an exchange rate of 64 ± 13 s-1 (38 ± 16 s-1 after cardiac arrest), whereas model-based fitting of QUASS Z-spectra yielded an exchange rate of 126 ± 25 s-1 (49 ± 13 s-1). CONCLUSION The model-based fitting of QUASS CEST Z-spectra enables consistent and accurate quantification of exchange parameters through Ω-plot construction by reducing error due to signal overlap and nonequilibrium CEST effects.
Collapse
Affiliation(s)
- Julius Juhyun Chung
- Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, GA
| | - Hahnsung Kim
- Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, GA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA
| | - Yang Ji
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA
| | - Dongshuang Lu
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA
| | - Iris Y. Zhou
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA
| | - Phillip Zhe Sun
- Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, GA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA
- Winship Cancer Institute, Emory University School of Medicine, Atlanta, GA
| |
Collapse
|
6
|
Zhang XY, Xu C, Wu XC, Qu QQ, Deng K. Evaluation of Amide Proton Transfer Imaging Combined With Serum Squamous Cell Carcinoma Antigen for Grading Cervical cancer. J Comput Assist Tomogr 2024:00004728-990000000-00383. [PMID: 39582402 DOI: 10.1097/rct.0000000000001699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2024]
Abstract
OBJECTIVE The aim of the study is to investigate the efficacy of amide proton transfer-weighted (APT) imaging combined with serum squamous cell carcinoma antigen (SCC-Ag) in grading cervical cancer. METHODS Sixty-three patients with surgically confirmed cervical SCC were enrolled and categorized into 3 groups: highly differentiated (G1), moderately differentiated (G2), and poorly differentiated (G3). The diagnostic efficacies of APT imaging and serum SCC-Ag, alone or in combination, for grading cervical SCC were compared. RESULTS The APT values measured by the 2 observers were in excellent agreement (intraclass correlation coefficient >0.75). Mean (± standard deviation) APT values for the high, moderate, and poor differentiation groups were 2.542 ± 0.215% (95% confidence interval [CI]: 2.423-2.677), 2.784 ± 0.175% (95% CI: 2.701-2.856), and 3.120 ± 0.221% (95% CI: 2.950-3.250), respectively. APT values for groups G2 and G3 were significantly higher than those for G1 (P < 0.05). APT values for identifying cervical SCC in groups G1 and G2, G2 and G3, and G1 and G3, had areas under the receiver operating characteristic curve, sensitivities, and specificities of 0.815 (95% confidence interval [CI]: 0.674-0.914), 82.1%, and 72.2%, 0.882 (95% CI: 0.751-0.959), 70.6%, and 92.7%, and 0.961 (95% CI: 0.835-0.998), 94.1%, and 94.4%, respectively. APT values were significantly and positively correlated with the histological grade of cervical SCC (Spearman's correlation [rs] = 0.731, P < 0.01). Serum SCC-Ag levels for the high, moderate, and poor differentiation groups were 1.60 (0.88-4.63) ng/mL, 4.10 (1.85-6.98) ng/mL, and 26.10 (9.65-70.00) ng/mL, respectively. The differences were statistically significant only between groups G1 and G3 and G2 and G3 (P < 0.05), whereas the differences between groups G1 and G2 were not statistically significant (P > 0.05). Spearman's analysis revealed a positive correlation between SCC-Ag levels and the histological grade of cervical SCC (rs = 0.573, P < 0.01). The diagnostic efficacy of APT imaging for the histological grading of cervical SCC was better than that of serum SCC-Ag, and the discriminatory efficacy of the combination of the 2 parameters was better than that of either alone. CONCLUSIONS The diagnostic efficacy of APT imaging was better than that of serum SCC-Ag, and the combined diagnostic utility of APT and SCC-Ag was better than that of the individual parameters.
Collapse
Affiliation(s)
| | - Chen Xu
- Clinical Medical College of Jining Medical University, Jining, Shandong, China
| | - Xing-Chen Wu
- Shandong Second Medical University, Weifang, Shandong, China
| | - Qian-Qian Qu
- From the Department of Radiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan Shandong, China
| | - Kai Deng
- From the Department of Radiology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan Shandong, China
| |
Collapse
|
7
|
Sun PZ. Quasi-steady-state (QUASS) reconstruction enhances T 1 normalization in apparent exchange-dependent relaxation (AREX) analysis: A reevaluation of T 1 correction in quantitative CEST MRI of rodent brain tumor models. Magn Reson Med 2024; 92:236-245. [PMID: 38380727 PMCID: PMC11055669 DOI: 10.1002/mrm.30056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 01/26/2024] [Accepted: 02/04/2024] [Indexed: 02/22/2024]
Abstract
PURPOSE The apparent exchange-dependent relaxation (AREX) analysis has been proposed as an effective means to correct T1 contribution in CEST quantification. However, it has been recognized that AREX T1 correction is not straightforward if CEST scans are not performed under the equilibrium condition. Our study aimed to test if quasi-steady-state (QUASS) reconstruction could boost the accuracy of the AREX metric under common non-equilibrium scan conditions. THEORY AND METHODS Numerical simulation and in vivo scans were performed to assess the AREX metric accuracy. The CEST signal was simulated under different relaxation delays, RF saturation amplitudes, and durations. The AREX was evaluated as a function of the bulk water T1 and labile proton concentration using the multiple linear regression model. AREX MRI was also assessed in brain tumor rodent models, with both apparent CEST scans and QUASS reconstruction. RESULTS Simulation showed that the AREX calculation from apparent CEST scans, under non-equilibrium conditions, had significant dependence on labile proton fraction ratio, RF saturation time, and T1. In comparison, QUASS-boosted AREX depended on the labile proton fraction ratio without significant dependence on T1 and RF saturation time. Whereas the apparent (2.7 ± 0.8%) and QUASS MTR asymmetry (2.8 ± 0.8%) contrast between normal and tumor regions of interest (ROIs) were significant, the difference was small. In comparison, AREX contrast between normal and tumor ROIs calculated from the apparent CEST scan and QUASS reconstruction was 3.8 ± 1.1%/s and 4.4 ± 1.2%/s, respectively, statistically different from each other. CONCLUSIONS AREX analysis benefits from the QUASS-reconstructed equilibrium CEST effect for improved T1 correction and quantitative CEST analysis.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA
- Winship Cancer Institute, Emory University, Atlanta, GA
- Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, GA
| |
Collapse
|
8
|
Xiang X, Li X, Lin H, Wang X. Amide proton transfer-weighted MRI in predicting pathological types of brain metastases in lung Cancer. Magn Reson Imaging 2024; 108:59-66. [PMID: 38330724 DOI: 10.1016/j.mri.2024.01.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Revised: 01/21/2024] [Accepted: 01/25/2024] [Indexed: 02/10/2024]
Abstract
Most brain metastases originate from lung cancer. The majority of cases of lung cancer can be categorized into squamous carcinoma and adenocarcinoma,necessitating distinct clinical treatments and yielding diverse prognoses.Therefore,accurate preoperative evaluation of pathological types through imaging techniques is essential. The objective of this study is to assess the capability of amide proton transfer-weighted(APTw) MRI in predicting the pathological types of brain metastases in lung cancer.Additionally,it seeks to evaluate whether APTw MRI can provide additional value to diffusion-weighted imaging(DWI) at MRI·In this study,a total of 32 participants(mean age,60 ± 9 years;14 men) underwent evaluation,comprising 9 with squamous carcinoma and 23 with adenocarcinoma.Interestingly,adenocarcinoma demonstrated elevated APTw values(2.70 ± 0.81% vs 1.82 ± 0.47%;P = 0.001) and a higher apparent diffusion coefficient(ADC) value(1.00 ± 0.40 × 10-3 mm2/s vs 0.77 ± 0.13 × 10-3 mm2/s;P<0.05) in comparison to squamous carcinoma. The area under the receiver operating characteristic curve(AUC) of APTw and ADC in distinguishing between squamous carcinoma and adenocarcinoma were found to be 0.84 and 0.63,respectively.Moreover,the combined area under the receiver operating characteristic curve of the two techniques is 0.84. Amide proton transfer-weighted has the potential to predict the pathological types of brain metastases in lung cancer.
Collapse
Affiliation(s)
- Xuyang Xiang
- The First Clinical Medical College of Gansu University of Chinese Medicine, Postal address:No.732 Jiayuguan West Road, Lanzhou 730,000, China
| | - Xiaozhong Li
- Department of Magnetic Resonance Imaging, Medical Imaging Center, Postal address:No.732 Jiayuguan West Road, Lanzhou 730,020, China.
| | - Huiting Lin
- The First Clinical Medical College of Gansu University of Chinese Medicine, Postal address:No.732 Jiayuguan West Road, Lanzhou 730,020, China
| | - Xufang Wang
- The First Clinical Medical College of Gansu University of Chinese Medicine, Postal address:No.732 Jiayuguan West Road, Lanzhou 730,020, China
| |
Collapse
|
9
|
Vasireddi A, Schaefer PW, Rohatgi S. Metabolic Imaging of Acute Ischemic Stroke (PET, 1Hydrogen Spectroscopy, 17Oxygen Imaging, 23Sodium MRI, pH Imaging). Neuroimaging Clin N Am 2024; 34:271-280. [PMID: 38604711 DOI: 10.1016/j.nic.2024.01.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/13/2024]
Abstract
Acute stroke imaging plays a vital and time-sensitive role in therapeutic decision-making. Current clinical workflows widely use computed tomography (CT) and magnetic resonance (MR) techniques including CT and MR perfusion to estimate the volume of ischemic penumbra at risk for infarction without acute intervention. The use of imaging techniques aimed toward evaluating the metabolic derangements underlying a developing infarct may provide additional information for differentiating the penumbra from benign oligemia and infarct core. The authors review several modalities of metabolic imaging including PET, hydrogen and oxygen spectroscopy, sodium MRI, and pH-weighted MRI.
Collapse
Affiliation(s)
- Anil Vasireddi
- Division of Neuroradiology, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA 02114, USA.
| | - Pamela W Schaefer
- Division of Neuroradiology, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA 02114, USA
| | - Saurabh Rohatgi
- Division of Neuroradiology, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA 02114, USA
| |
Collapse
|
10
|
Zhou IY, Ji Y, Zhao Y, Malvika V, Sun PZ, Zu Z. Specific and rapid guanidinium CEST imaging using double saturation power and QUASS analysis in a rodent model of global ischemia. Magn Reson Med 2024; 91:1512-1527. [PMID: 38098305 PMCID: PMC10872646 DOI: 10.1002/mrm.29960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 10/17/2023] [Accepted: 11/20/2023] [Indexed: 02/03/2024]
Abstract
PURPOSE Guanidinium CEST is sensitive to metabolic changes and pH variation in ischemia, and it can offer advantages over conventional pH-sensitive amide proton transfer (APT) imaging by providing hyperintense contrast in stroke lesions. However, quantifying guanidinium CEST is challenging due to multiple overlapping components and a close frequency offset from water. This study aims to evaluate the applicability of a new rapid and model-free CEST quantification method using double saturation power, termed DSP-CEST, for isolating the guanidinium CEST effect from confounding factors in ischemia. To further reduce acquisition time, the DSP-CEST was combined with a quasi-steady state (QUASS) CEST technique to process non-steady-state CEST signals. METHODS The specificity and accuracy of the DSP-CEST method in quantifying the guanidinium CEST effect were assessed by comparing simulated CEST signals with/without the contribution from confounding factors. The feasibility of this method for quantifying guanidinium CEST was evaluated in a rat model of global ischemia induced by cardiac arrest and compared to a conventional multiple-pool Lorentzian fit method. RESULTS The DSP-CEST method was successful in removing all confounding components and quantifying the guanidinium CEST signal increase in ischemia. This suggests that the DSP-CEST has the potential to provide hyperintense contrast in stroke lesions. Additionally, the DSP-CEST was shown to be a rapid method that does not require the acquisition of the entire or a portion of the CEST Z-spectrum that is required in conventional model-based fitting approaches. CONCLUSION This study highlights the potential of DSP-CEST as a valuable tool for rapid and specific detection of viable tissues.
Collapse
Affiliation(s)
- Iris Y. Zhou
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, US
| | - Yang Ji
- Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Yu Zhao
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Viswanathan Malvika
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, US
| | - Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, US
- Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, GA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
- Department of Biomedical Engineering, Vanderbilt University, Nashville, US
| |
Collapse
|
11
|
Wu Q, Qi Y, Gong P, Huang B, Cheng G, Liang D, Zheng H, Sun PZ, Wu Y. Fast and robust pulsed chemical exchange saturation transfer (CEST) MRI using a quasi-steady-state (QUASS) algorithm at 3 T. Magn Reson Imaging 2024; 105:29-36. [PMID: 37898416 DOI: 10.1016/j.mri.2023.10.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 10/21/2023] [Accepted: 10/22/2023] [Indexed: 10/30/2023]
Abstract
Chemical exchange saturation transfer (CEST) has emerged as a powerful technique to image dilute labile protons. However, its measurement depends on the RF saturation duration (Tsat) and relaxation delay (Trec). Although the recently developed quasi-steady-state (QUASS) solution can reconstruct equilibrium CEST effects under continuous-wave RF saturation, it does not apply to pulsed-CEST MRI on clinical scanners with restricted hardware or specific absorption rate limits. This study proposed a QUASS algorithm for pulsed-CEST MRI and evaluated its performance in muscle CEST measurement. An approximated expression of a steady-state pulsed-CEST signal was incorporated in the off-resonance spin-lock model, from which the QUASS pulsed-CEST effect was derived. Numerical simulation, creatine phantom, and healthy volunteer scans were conducted at 3 T. The CEST effect was quantified with asymmetry analysis in the simulation and phantom experiments. CEST effects of creatine, amide proton transfer, phosphocreatine, and combined magnetization transfer and nuclear Overhauser effects were isolated from a multi-pool Lorentzian model in muscles. Apparent and QUASS CEST measurements were compared under different Tsat/Trec and duty cycles. Paired Student's t-test was employed with P < 0.05 as statistically significant. The simulation, phantom, and human studies showed the strong impact of Tsat/Trec on apparent CEST measurements, which were significantly smaller than the corresponding QUASS CEST measures, especially under short Tsat/Trec times. In comparison, the QUASS algorithm mitigates such impact and enables accurate CEST measurements under short Tsat/Trec times. In conclusion, the QUASS algorithm can accelerate robust pulsed-CEST MRI, promising the efficient detection and evaluation of muscle diseases in clinical settings.
Collapse
Affiliation(s)
- Qiting Wu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China; Medical AI Lab, School of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, Guangdong, China
| | - Yulong Qi
- Department of Medical Imaging, Peking University Shenzhen Hospital, Shenzhen, Guangdong, China
| | - Pengcheng Gong
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Bingsheng Huang
- Medical AI Lab, School of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, Guangdong, China
| | - Guanxun Cheng
- Department of Medical Imaging, Peking University Shenzhen Hospital, Shenzhen, Guangdong, China
| | - Dong Liang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Phillip Zhe Sun
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA
| | - Yin Wu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China.
| |
Collapse
|
12
|
Foo LS, Larkin JR, Sutherland BA, Ray KJ, Yap WS, Goh CH, Hum YC, Lai KW, Harston G, Tee YK. Investigation of relayed nuclear Overhauser enhancement effect at -1.6 ppm in an ischemic stroke model. Quant Imaging Med Surg 2023; 13:7879-7892. [PMID: 38106293 PMCID: PMC10722023 DOI: 10.21037/qims-23-510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Accepted: 08/28/2023] [Indexed: 12/19/2023]
Abstract
BACKGROUND When an ischemic stroke happens, it triggers a complex signalling cascade that may eventually lead to neuronal cell death if no reperfusion. Recently, the relayed nuclear Overhauser enhancement effect at -1.6 ppm [NOE(-1.6 ppm)] has been postulated may allow for a more in-depth analysis of the ischemic injury. This study assessed the potential utility of NOE(-1.6 ppm) in an ischemic stroke model. METHODS Diffusion-weighted imaging, perfusion-weighted imaging, and chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) data were acquired from five rats that underwent scans at 9.4 T after middle cerebral artery occlusion. RESULTS The apparent diffusion coefficient (ADC), cerebral blood flow (CBF), and apparent exchange-dependent relaxations (AREX) at 3.5 ppm and NOE(-1.6 ppm) were quantified. AREX(3.5 ppm) and NOE(-1.6 ppm) were found to be hypointense and exhibited different signal patterns within the ischemic tissue. The NOE(-1.6 ppm) deficit areas were equal to or larger than the ADC deficit areas, but smaller than the AREX(3.5 ppm) deficit areas. This suggested that NOE(-1.6 ppm) might further delineate the acidotic tissue estimated using AREX(3.5 ppm). Since NOE(-1.6 ppm) is closely related to membrane phospholipids, NOE(-1.6 ppm) potentially highlighted at-risk tissue affected by lipid peroxidation and membrane damage. Altogether, the ADC/NOE(-1.6 ppm)/AREX(3.5 ppm)/CBF mismatches revealed four zones of increasing sizes within the ischemic tissue, potentially reflecting different pathophysiological information. CONCLUSIONS Using CEST coupled with ADC and CBF, the ischemic tissue may thus potentially be separated into four zones to better understand the pathophysiology after stroke and improve ischemic tissue fate definition. Further verification of the potential utility of NOE(-1.6 ppm) may therefore lead to a more precise diagnosis.
Collapse
Affiliation(s)
- Lee Sze Foo
- Lee Kong Chian Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Kajang, Malaysia
| | - James R. Larkin
- Department of Oncology, Cancer Research UK and Medical Research Council Oxford Institute for Radiation Oncology, University of Oxford, Oxford, UK
| | - Brad A. Sutherland
- Tasmanian School of Medicine, College of Health and Medicine, University of Tasmania, Hobart, Australia
| | - Kevin J. Ray
- Department of Oncology, Cancer Research UK and Medical Research Council Oxford Institute for Radiation Oncology, University of Oxford, Oxford, UK
| | - Wun-She Yap
- Lee Kong Chian Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Kajang, Malaysia
| | - Choon-Hian Goh
- Lee Kong Chian Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Kajang, Malaysia
| | - Yan Chai Hum
- Lee Kong Chian Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Kajang, Malaysia
| | - Khin Wee Lai
- Faculty of Engineering, Department of Biomedical Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - George Harston
- Acute Stroke Service, Oxford University Hospitals National Health Service Foundation Trust, Oxford, UK
| | - Yee Kai Tee
- Lee Kong Chian Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Kajang, Malaysia
| |
Collapse
|
13
|
Wu L, Lu D, Sun PZ. Comparison of model-free Lorentzian and spinlock model-based fittings in quantitative CEST imaging of acute stroke. Magn Reson Med 2023; 90:1958-1968. [PMID: 37335834 PMCID: PMC10538953 DOI: 10.1002/mrm.29772] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 05/14/2023] [Accepted: 06/01/2023] [Indexed: 06/21/2023]
Abstract
PURPOSE CEST MRI detects complex tissue changes following acute stroke. Our study aimed to test if spinlock model-based fitting of the quasi-steady-state (QUASS)-reconstructed equilibrium CEST MRI improves the determination of multi-pool signal changes over the commonly-used model-free Lorentzian fitting in acute stroke. THEORY AND METHODS Multiple three-pool CEST Z-spectra were simulated using Bloch-McConnell equations for a range of T1 , relaxation delay, and saturation times. The multi-pool CEST signals were solved from the simulated Z-spectra to test the accuracy of routine Lorentzian (model-free) and spinlock (model-based) fittings without and with QUASS reconstruction. In addition, multiparametric MRI scans were obtained in rat models of acute stroke, including relaxation, diffusion, and CEST Z-spectrum. Finally, we compared model-free and model-based per-pixel CEST quantification in vivo. RESULTS The spinlock model-based fitting of QUASS CEST MRI provided a nearly T1 -independent determination of multi-pool CEST signals, advantageous over the fittings of apparent CEST MRI (model-free and model-based). In vivo data also demonstrated that the spinlock model-based QUASS fitting captured significantly different changes in semisolid magnetization transfer (-0.9 ± 0.8 vs. 0.3 ± 0.8%), amide (-1.1 ± 0.4 vs. -0.5 ± 0.2%), and guanidyl (1.0 ± 0.4 vs. 0.7 ± 0.3%) signals over the model-free Lorentzian analysis. CONCLUSION Our study demonstrated that spinlock model-based fitting of QUASS CEST MRI improved the determination of the underlying tissue changes following acute stroke, promising further clinical translation of quantitative CEST imaging.
Collapse
Affiliation(s)
- Limin Wu
- Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Dongshuang Lu
- Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Phillip Zhe Sun
- Massachusetts General Hospital, Harvard Medical School, Boston, MA
- Emory National Primate Research Center, Emory University, Atlanta GA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta GA
| |
Collapse
|
14
|
Sun PZ. Numerical simulation-based assessment of pH-sensitive chemical exchange saturation transfer MRI quantification accuracy across field strengths. NMR IN BIOMEDICINE 2023; 36:e5000. [PMID: 37401645 PMCID: PMC11990165 DOI: 10.1002/nbm.5000] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 04/27/2023] [Accepted: 06/12/2023] [Indexed: 07/05/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI detects dilute labile protons via their exchange with bulk water, conferring pH sensitivity. Based on published exchange and relaxation properties, a 19-pool simulation was used to model the brain pH-dependent CEST effect and assess the accuracy of quantitative CEST (qCEST) analysis across magnetic field strengths under typical scan conditions. First, the optimal B1 amplitude was determined by maximizing pH-sensitive amide proton transfer (APT) contrast under the equilibrium condition. Apparent and quasi-steady-state (QUASS) CEST effects were then derived under the optimal B1 amplitude as functions of pH, RF saturation duration, relaxation delay, Ernst flip angle, and field strength. Finally, CEST effects, particularly the APT signal, were isolated with spinlock model-based Z-spectral fitting to evaluate the accuracy and consistency of CEST quantification. Our data showed that QUASS reconstruction significantly improved the consistency between simulated and equilibrium Z-spectra. The residual difference between QUASS and equilibrium CEST Z-spectra was, on average, 30 times less than that of the apparent CEST Z-spectra across field strengths, saturation, and repetition times. Also, the spinlock fitting of the QUASS CEST effect significantly reduced the residual errors 9-fold. Furthermore, the isolated APT amplitude from QUASS reconstruction was consistent and higher than the apparent CEST analysis under nonequilibrium conditions. To summarize, this study confirmed that QUASS reconstruction facilitates accurate determination of the CEST system under different scan protocols across field strengths, with the potential to help standardize CEST quantification.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, GA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA
| |
Collapse
|
15
|
Nagar D, Vladimirov N, Farrar CT, Perlman O. Dynamic and rapid deep synthesis of chemical exchange saturation transfer and semisolid magnetization transfer MRI signals. Sci Rep 2023; 13:18291. [PMID: 37880343 PMCID: PMC10600114 DOI: 10.1038/s41598-023-45548-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 10/20/2023] [Indexed: 10/27/2023] Open
Abstract
Model-driven analysis of biophysical phenomena is gaining increased attention and utility for medical imaging applications. In magnetic resonance imaging (MRI), the availability of well-established models for describing the relations between the nuclear magnetization, tissue properties, and the externally applied magnetic fields has enabled the prediction of image contrast and served as a powerful tool for designing the imaging protocols that are now routinely used in the clinic. Recently, various advanced imaging techniques have relied on these models for image reconstruction, quantitative tissue parameter extraction, and automatic optimization of acquisition protocols. In molecular MRI, however, the increased complexity of the imaging scenario, where the signals from various chemical compounds and multiple proton pools must be accounted for, results in exceedingly long model simulation times, severely hindering the progress of this approach and its dissemination for various clinical applications. Here, we show that a deep-learning-based system can capture the nonlinear relations embedded in the molecular MRI Bloch-McConnell model, enabling a rapid and accurate generation of biologically realistic synthetic data. The applicability of this simulated data for in-silico, in-vitro, and in-vivo imaging applications is then demonstrated for chemical exchange saturation transfer (CEST) and semisolid macromolecule magnetization transfer (MT) analysis and quantification. The proposed approach yielded 63-99% acceleration in data synthesis time while retaining excellent agreement with the ground truth (Pearson's r > 0.99, p < 0.0001, normalized root mean square error < 3%).
Collapse
Affiliation(s)
- Dinor Nagar
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Nikita Vladimirov
- Department of Biomedical Engineering, Tel Aviv University, 6997801, Tel Aviv, Israel
| | - Christian T Farrar
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| | - Or Perlman
- Department of Biomedical Engineering, Tel Aviv University, 6997801, Tel Aviv, Israel.
- Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel.
| |
Collapse
|
16
|
Kim H, Kim J, Sun PZ. CEST2022 - mapping multi-pool CEST signal changes in an animal model of brain tumor with quasi-steady-state reconstruction-empowered CEST quantification. Magn Reson Imaging 2023:S0730-725X(23)00100-5. [PMID: 37321379 DOI: 10.1016/j.mri.2023.06.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Accepted: 06/12/2023] [Indexed: 06/17/2023]
Abstract
Chemical exchange saturated transfer (CEST) MRI has biomarker potential to assess tissue microenvironment in brain tumors. Multi-pool Lorentzian or spinlock models provides useful insights into the CEST contrast mechanism. However, T1 contribution to the complex overlapping effects of brain tumors is difficult under the non-equilibrium state. Therefore, this study evaluated T1 contributions on multi-pool parameters with quasi-steady-state (QUASS) algorithm reconstructed equilibrium data. MRI scans were performed in rat brain tumor models, including relaxation, diffusion, and CEST imaging. A pixel-wise seven-pool spinlock-model was employed to fit QUASS reconstructed CEST Z-spectra and evaluated the magnetization transfer (MT), amide, amine, guanidyl, and nuclear-overhauled effect (NOE) signals in tumor and normal tissues. In addition, T1 was estimated from the spinlock-model fitting and compared with measured T1. We observed tumor had a statistically significant increase in the amide signal (p < 0.001) and decreases in the MT and NOE signals (p < 0.001). On the other hand, the differences in amine and guanidyl between the tumor and contralateral normal regions were not statistically significant. The differences between measured and estimated T1 values were 8% in the normal tissue and 4% in the tumor. Furthermore, the isolated MT signal strongly correlated with R1 (r = 0.96, P < 0.001). In summary, we successfully unraveled multi-factorial effects in the CEST signal using spinlock-model fitting and QUASS method and demonstrated the effect of T1 relaxation on MT and NOE.
Collapse
Affiliation(s)
- Hahnsung Kim
- Emory National Primate Research Center, Emory University, Atlanta, GA, United States of America; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States of America.
| | - Jinsuh Kim
- Emory National Primate Research Center, Emory University, Atlanta, GA, United States of America; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States of America
| | - Phillip Zhe Sun
- Emory National Primate Research Center, Emory University, Atlanta, GA, United States of America; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States of America.
| |
Collapse
|
17
|
Sun PZ. Generalization of quasi-steady-state reconstruction to CEST MRI with two-tiered RF saturation and gradient-echo readout-Synergistic nuclear Overhauser enhancement contribution to brain tumor amide proton transfer-weighted MRI. Magn Reson Med 2023; 89:2014-2023. [PMID: 36579767 DOI: 10.1002/mrm.29570] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 12/13/2022] [Accepted: 12/14/2022] [Indexed: 12/30/2022]
Abstract
PURPOSE While amide proton transfer-weighted (APTw) MRI has been adopted in tumor imaging, there are concurrent APT, magnetization transfer, and nuclear Overhauser enhancement changes. Also, the APTw image is confounded by relaxation changes, particularly when the relaxation delay and saturation time are not sufficiently long. Our study aimed to extend a quasi-steady-state (QUASS) solution to determine the contribution of the multipool CEST signals to the observed tumor APTw contrast. METHODS Our study derived the QUASS solution for a multislice CEST-MRI sequence with an interleaved RF saturation and gradient-echo readout between signal averaging. Multiparametric MRI scans were obtained in rat brain tumor models, including T1 , T2 , diffusion, and CEST scans. Finally, we performed spinlock model-based multipool fitting to determine multiple concurrent CEST signal changes in the tumor. RESULTS The QUASS APTw MRI showed small but significant differences in normal and tumor tissues and their contrast from the acquired asymmetry calculation. The spinlock model-based fitting showed significant differences in semisolid magnetization transfer, amide, and nuclear Overhauser enhancement effects between the apparent and QUASS CEST MRI. In addition, we determined that the tumor APTw contrast is due to synergistic APT increase (+3.5 ppm) and NOE decrease (-3.5 ppm), with their relative contribution being about one third and two thirds under a moderate B1 of 0.75 μT at 4.7 T. CONCLUSION Our study generalized QUASS analysis to gradient-echo image readout and quantified the underlying tumor CEST signal changes, providing an improved elucidation of the commonly used APTw MRI.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Emory Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, Georgia, USA.,Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA
| |
Collapse
|
18
|
Sun PZ. Demonstration of accurate multi-pool chemical exchange saturation transfer MRI quantification - Quasi-steady-state reconstruction empowered quantitative CEST analysis. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 348:107379. [PMID: 36689786 PMCID: PMC10023465 DOI: 10.1016/j.jmr.2023.107379] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 01/05/2023] [Accepted: 01/15/2023] [Indexed: 05/18/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI is sensitive to dilute labile protons and microenvironment properties, yet CEST quantification has been challenging. This difficulty is because the CEST measurement depends not only on the underlying CEST system but also on the scan protocols, including RF saturation amplitude, duration, and repetition time. In addition, T1 normalization is not straightforward under non-equilibrium conditions. Recently, a quasi-steady-state (QUASS) algorithm was established to reconstruct the desired equilibrium state from experimental measurements. Our study aimed to determine the accuracy of spinlock-model-based multi-pool CEST quantification using numerical simulations and phantom experiments. In short, CEST Z-spectra were simulated for a representative 3-pool model, and CEST amplitudes were solved with spinlock model-based multi-pool fitting and assessed as a function of RF saturation time (Ts), repetition time (TR), and T1. Although the apparent CEST signals showed significant T1 dependence, such relationships were not observed following QUASS reconstruction. To test the accuracy of T1 correction, a multi-vial phantom of nicotinamide and creatine was doped with manganese chloride, resulting in T1 ranging from 1 s to beyond 2 s. The multi-labile signals determined from the routine measurements showed significant dependence on Ts, TR, and T1. In contrast, CEST signals from the QUASS reconstruction showed consistent quantification independent of such variables. To summarize, our study demonstrated that accurate CEST quantification is feasible in multi-pool CEST systems with the spinlock-model-based fitting of QUASS CEST MRI.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, GA, United States; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States.
| |
Collapse
|
19
|
Wu Y, Sun PZ. Demonstration of pH imaging in acute stroke with endogenous ratiometric chemical exchange saturation transfer magnetic resonance imaging at 2 ppm. NMR IN BIOMEDICINE 2023; 36:e4850. [PMID: 36259279 DOI: 10.1002/nbm.4850] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 10/11/2022] [Accepted: 10/11/2022] [Indexed: 06/16/2023]
Abstract
pH change is often considered a hallmark of metabolic disruption in diseases such as ischemic stroke and cancer. Chemical exchange saturation transfer (CEST) MRI, particularly amide proton transfer (APT), has emerged as a noninvasive pH imaging approach. However, there are changes in multipool CEST effects besides APT MRI. Our study investigated radiofrequency (RF) amplitude-based ratiometric CEST pH imaging in acute stroke. Briefly, adult male Wistar rats underwent CEST MRI under two RF saturation (B1 ) levels of 0.75 and 1.5 μT following middle cerebral artery occlusion. Magnetization transfer (MT), direct water saturation, CEST at 2 ppm (CEST@2 ppm), amine (2.75 ppm), and APT (3.5 ppm) effects were resolved with the multipool Lorentzian fitting approach. The ratiometric analysis was measured in the ischemic lesion and the contralateral normal area, which was also correlated with pH-specific MT and the relaxation normalized APT (MRAPT) index. MT, amine CEST effect, and their respective ratiometric indices did not show significant changes in ischemic regions (p > 0.05), as expected. Whereas APT decreased in the ischemic lesion for B1 of 1.5 μT (p < 0.01), the correlation between the amide ratio with MRAPT index was moderate (r = 0.52, p = 0.02). By comparison, the ischemic tissue showed a significantly increased CEST@2 ppm for both saturation levels from the contralateral normal area (p ≤ 0.01). Importantly, the CEST@2 ppm ratio decreased in the ischemic lesion (p < 0.01), which highly correlated with the MRAPT index (r = 0.93, p < 0.001). To summarize, our study demonstrated the feasibility of endogenous CEST@2 ppm ratiometric imaging of pH upon acute stroke, promising to detect pH changes in metabolic diseases.
Collapse
Affiliation(s)
- Yin Wu
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA
- Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, Georgia, USA
| |
Collapse
|
20
|
Jackson LR, Masi MR, Selman BM, Sandusky GE, Zarrinmayeh H, Das SK, Maharjan S, Wang N, Zheng QH, Pollok KE, Snyder SE, Sun PZ, Hutchins GD, Butch ER, Veronesi MC. Use of multimodality imaging, histology, and treatment feasibility to characterize a transgenic Rag2-null rat model of glioblastoma. Front Oncol 2022; 12:939260. [PMID: 36483050 PMCID: PMC9722958 DOI: 10.3389/fonc.2022.939260] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Accepted: 10/20/2022] [Indexed: 11/23/2022] Open
Abstract
Many drugs that show potential in animal models of glioblastoma (GBM) fail to translate to the clinic, contributing to a paucity of new therapeutic options. In addition, animal model development often includes histologic assessment, but multiparametric/multimodality imaging is rarely included despite increasing utilization in patient cancer management. This study developed an intracranial recurrent, drug-resistant, human-derived glioblastoma tumor in Sprague-Dawley Rag2-Rag2 tm1Hera knockout rat and was characterized both histologically and using multiparametric/multimodality neuroimaging. Hybrid 18F-fluoroethyltyrosine positron emission tomography and magnetic resonance imaging, including chemical exchange saturation transfer (18F-FET PET/CEST MRI), was performed for full tumor viability determination and characterization. Histological analysis demonstrated human-like GBM features of the intracranially implanted tumor, with rapid tumor cell proliferation (Ki67 positivity: 30.5 ± 7.8%) and neovascular heterogeneity (von Willebrand factor VIII:1.8 to 5.0% positivity). Early serial MRI followed by simultaneous 18F-FET PET/CEST MRI demonstrated consistent, predictable tumor growth, with exponential tumor growth most evident between days 35 and 49 post-implantation. In a second, larger cohort of rats, 18F-FET PET/CEST MRI was performed in mature tumors (day 49 post-implantation) for biomarker determination, followed by evaluation of single and combination therapy as part of the model development and validation. The mean percentage of the injected dose per mL of 18F-FET PET correlated with the mean %CEST (r = 0.67, P < 0.05), but there was also a qualitative difference in hot spot location within the tumor, indicating complementary information regarding the tumor cell demand for amino acids and tumor intracellular mobile phase protein levels. Finally, the use of this glioblastoma animal model for therapy assessment was validated by its increased overall survival after treatment with combination therapy (temozolomide and idasanutlin) (P < 0.001). Our findings hold promise for a more accurate tumor viability determination and novel therapy assessment in vivo in a recently developed, reproducible, intracranial, PDX GBM.
Collapse
Affiliation(s)
- Luke R. Jackson
- Department of Radiology and Imaging Sciences, Indiana University (IU) School of Medicine, Indianapolis, IN, United States
| | - Megan R. Masi
- Department of Radiology and Imaging Sciences, Indiana University (IU) School of Medicine, Indianapolis, IN, United States
| | - Bryce M. Selman
- Department of Pathology and Laboratory Medicine, Indiana University (IU) School of Medicine, Indianapolis, IN, United States
| | - George E. Sandusky
- Department of Pathology and Laboratory Medicine, Indiana University (IU) School of Medicine, Indianapolis, IN, United States
| | - Hamideh Zarrinmayeh
- Department of Radiology and Imaging Sciences, Indiana University (IU) School of Medicine, Indianapolis, IN, United States
| | - Sudip K. Das
- Department of Pharmaceutical Sciences, Butler University, Indianapolis, IN, United States
| | - Surendra Maharjan
- Department of Radiology and Imaging Sciences, Indiana University (IU) School of Medicine, Indianapolis, IN, United States
| | - Nian Wang
- Department of Radiology and Imaging Sciences, Indiana University (IU) School of Medicine, Indianapolis, IN, United States
| | - Qi-Huang Zheng
- Department of Radiology and Imaging Sciences, Indiana University (IU) School of Medicine, Indianapolis, IN, United States
| | - Karen E. Pollok
- Department of Pediatrics, Indiana University (IU) School of Medicine, Indianapolis, IN, United States
| | - Scott E. Snyder
- Department of Radiology and Imaging Sciences, Indiana University (IU) School of Medicine, Indianapolis, IN, United States
| | - Phillip Zhe Sun
- Department of Radiology and Imaging Sciences, Emory School of Medicine, Atlanta, GA, United States
| | - Gary D. Hutchins
- Department of Radiology and Imaging Sciences, Indiana University (IU) School of Medicine, Indianapolis, IN, United States
| | - Elizabeth R. Butch
- Department of Radiology and Imaging Sciences, Indiana University (IU) School of Medicine, Indianapolis, IN, United States
| | - Michael C. Veronesi
- Department of Radiology and Imaging Sciences, Indiana University (IU) School of Medicine, Indianapolis, IN, United States,*Correspondence: Michael C. Veronesi,
| |
Collapse
|