1
|
Early-Life Metabolic and Hormonal Markers in Blood and Growth until Age 2 Years: Results from a Randomized Controlled Trial in Healthy Infants Fed a Modified Low-Protein Infant Formula. Nutrients 2021; 13:nu13041159. [PMID: 33915788 PMCID: PMC8067012 DOI: 10.3390/nu13041159] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 03/26/2021] [Accepted: 03/29/2021] [Indexed: 11/21/2022] Open
Abstract
Background: High protein intake in early life is associated with an increased risk of childhood obesity. Dietary protein intake may be a key mechanistic modulator through alterations in endocrine and metabolic responses. Objective: We aimed to determine the impact of different protein intake of infants on blood metabolic and hormonal markers at the age of four months. We further aimed to investigate the association between these markers and anthropometric parameters and body composition until the age of two years. Design: Term infants received a modified low-protein formula (mLP) (1.7 g protein/100 kcal) or a specifically designed control formula (CTRL) (2.1 g protein/100 kcal) until 6 months of age in a double blinded RCT. The outcomes were compared with a breast-fed (BF) group. Glucose, insulin, leptin, IGF-1, IGF-BP1, -BP2, and -BP3 levels were measured at the age of 4 months. Anthropometric parameters and body composition were assessed until the age of 2 years. Groups were compared using linear regression analysis. Results: No significant differences were observed in any of the blood parameters between the formula groups (n = 53 mLP; n = 44 CTRL) despite a significant difference in protein intake. Insulin and HOMA-IR were higher in both formula groups compared to the BF group (n = 36) (p < 0.001). IGF-BP1 was lower in both formula groups compared to the BF group (p < 0.01). We found a lower IGF-BP2 level in the CTRL group compared to the BF group (p < 0.01) and a higher IGF-BP3 level in the mLP group compared to the BF group (p = 0.03). There were no significant differences in glucose, leptin, and IGF-1 between the three feeding groups. We found specific associations of all early-life metabolic and hormonal blood parameters with long-term growth and body composition except for IGF-1. Conclusions: Reducing protein intake by 20% did not result in a different metabolic profile in formula-fed infants at 4 months of age. Formula-fed infants had a lower insulin sensitivity compared to breast-fed infants. We found associations between all metabolic and hormonal markers (except for IGF-1) determined at age 4 months and growth and body composition up to two years of age.
Collapse
|
2
|
Validation of saliva and urine use and sampling time on the doubly labelled water method to measure energy expenditure, body composition and water turnover in male and female cats. Br J Nutr 2020; 124:457-469. [PMID: 32172691 DOI: 10.1017/s0007114520000963] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Less invasive protocols are necessary to study energy expenditure (EE) of cats living in homes for expressing their normal living conditions. The present study compared sampling times and the use of saliva, urine and blood to measure 2H and 18O to apply the doubly labelled water method. In the first study, four cats were used to evaluate the enrichment (2, 4, 6, 7 and 8 h) and elimination (2, 4, 6, 8, 10, 12, 14, 16, 18 and 20 d) of 2H and 18O (subcutaneously injected). The maximum enrichment was after 5 h (R2 0·82) of injection, with an Ln linear elimination of both isotopes (P < 0·001; R2 0·99). The results of EE were similar, regardless of the sampling time used (P = 0·999). In the second study, seven male cats and seven female cats were used. Before and after isotope injection (5 h, 7 d, 10 d and 14 d), blood, saliva and urine were collected. Isotope enrichment was lower in urine (P < 0·05) and at the similar level in blood and saliva. Isotope elimination was similar for all fluids (P < 0·473). The EE calculated with blood and saliva was similar but higher for urine (P = 0·015). According to Bland-Altman statistics, blood and saliva presented low bias and high correlation (P < 0·001), but this was not observed for urine (P = 0·096). Higher EE was observed for male cats (384 (se 39) kJ/kg0·67 per d) than for female cats (337 (se 34) kJ/kg0·67 per d; P < 0·05). The sampling time for the method is flexible, and saliva can be used as a substitute for blood.
Collapse
|
3
|
Junghans P, Strauch G, Voigt J. In vitro application of carbonic anhydrase to accelerate the equilibration of 18O between H 2O and CO 2 for the rapid measurement of 18O/ 16O isotope ratios in aqueous samples. ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES 2020; 56:314-323. [PMID: 32490744 DOI: 10.1080/10256016.2020.1772253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2020] [Accepted: 05/06/2020] [Indexed: 06/11/2023]
Abstract
A novel method of the accelerated equilibration of 18O between CO2 and H2O for the measurement of the 18O/16O isotope ratios in aqueous samples with natural isotope abundances is presented. This rapid equilibrium method is based on the in vitro application of the enzyme carbonic anhydrase (CA). The CA from bovine erythrocytes was adsorptively fixed to 3-mm glass beads with an etched surface. After the addition of this carrier-fixed CA catalyst to the water sample, the isotope equilibrium was already reached after 1 h. The previously used non-catalysed 18O isotope exchange in water samples needs about 24 h. Whole blood samples also showed fast 18O isotope equilibration, which definitely results from the native presence of CA in erythrocytes. By shortening the time for sample preparation, the CA catalysed technique can significantly increase the throughput of the samples to be measured, and also 18O and 2H measurement by means of isotope ratio mass spectrometry (IRMS) may be synchronized. The 2H and 18O sample preparation can be performed in the same reaction vessel because cross-effects at the simultaneous use of Pt and CA catalysts do not occur.
Collapse
Affiliation(s)
- Peter Junghans
- Institute of Nutritional Physiology "Oskar Kellner", Leibniz Institute for Farm Animal Biology (FBN), Dummerstorf, Germany
| | - Gerhard Strauch
- Helmholtz-Zentrum für Umweltforschung - UFZ, Leipzig, Germany
| | - Jürgen Voigt
- Institute of Nutritional Physiology "Oskar Kellner", Leibniz Institute for Farm Animal Biology (FBN), Dummerstorf, Germany
| |
Collapse
|
4
|
Comparing saliva and urine samples for measuring breast milk intake with the 2H oxide dose-to-mother technique among children 2-4 months old. Br J Nutr 2019; 123:232-240. [PMID: 31623693 PMCID: PMC7015877 DOI: 10.1017/s0007114519002642] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Saliva and urine are the two main body fluids sampled when breast milk intake is measured with the 2H oxide dose-to-mother technique. However, these two body fluids may generate different estimates of breast milk intake due to differences in isotope enrichment. Therefore, we aimed to assess how the estimated amount of breast milk intake differs when based on saliva and urine samples and to explore whether the total energy expenditure of the mothers is related to breast milk output. We used a convenience sample of thirteen pairs of mothers and babies aged 2–4 months, who were exclusively breastfed and apparently healthy. To assess breast milk intake, we administered doubly labelled water to the mothers and collected saliva samples from them, while simultaneously collecting both saliva and urine from their babies over a 14-d period. Isotope ratio MS was used to analyse the samples for 2H and 18O enrichments. Mean breast milk intake based on saliva samples was significantly higher than that based on urine samples (854·5 v. 812·8 g/d, P = 0·029). This can be attributed to slightly higher isotope enrichments in saliva and to a poorer model fit for urine samples as indicated by a higher square root of the mean square error (14·6 v. 10·4 mg/kg, P = 0·001). Maternal energy expenditure was not correlated with breast milk output. Our study suggests that saliva sampling generates slightly higher estimates of breast milk intake and is more precise as compared with urine and that maternal energy expenditure does not influence breast milk output.
Collapse
|
5
|
Milani GP, Groothoff JW, Vianello FA, Fossali EF, Paglialonga F, Edefonti A, Agostoni C, Consonni D, van Harskamp D, van Goudoever JB, Schierbeek H, Oosterveld MJS. Bioimpedance and Fluid Status in Children and Adolescents Treated With Dialysis. Am J Kidney Dis 2017; 69:428-435. [PMID: 28089477 DOI: 10.1053/j.ajkd.2016.10.023] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2016] [Accepted: 10/09/2016] [Indexed: 11/11/2022]
Abstract
BACKGROUND Assessment of hydration status in patients with chronic kidney failure treated by dialysis is crucial for clinical management decisions. Dilution techniques are considered the gold standard for measurement of body fluid volumes, but they are unfit for day-to-day care. Multifrequency bioimpedance has been shown to be of help in clinical practice in adults and its use in children and adolescents has been advocated. We investigated whether application of multifrequency bioimpedance is appropriate for total-body water (TBW) and extracellular water (ECW) measurement in children and adolescents on dialysis therapy. STUDY DESIGN A study of diagnostic test accuracy. SETTING & PARTICIPANTS 16 young dialysis patients (before a hemodialysis session or after peritoneal dialysis treatment) from the Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy, and the Emma Children's Hospital-Academic Medical Center, Amsterdam, the Netherlands. INDEX TEST TBW and ECW volumes assessed by multifrequency bioimpedance. REFERENCE TESTS TBW and ECW volumes measured by deuterium and bromide dilution, respectively. RESULTS Mean TBW volumes determined by multifrequency bioimpedance and deuterium dilution were 19.2±8.7 (SD) and 19.3±8.3L, respectively; Bland-Altman analysis showed a mean bias between the 2 methods of -0.09 (95% limits of agreement, -2.1 to 1.9) L. Mean ECW volumes were 8.9±4.0 and 8.3±3.3L measured by multifrequency bioimpedance and bromide dilution, respectively; mean bias between the 2 ECW measurements was +0.6 (95% limits of agreement, -2.3 to 3.5). LIMITATIONS Participants ingested the deuterated water at home without direct supervision by investigators, small number of patients, repeated measurements in individual patients were not performed. CONCLUSIONS Multifrequency bioimpedance measurements were unbiased but imprecise in comparison to dilution techniques. We conclude that multifrequency bioimpedance measurements cannot precisely estimate TBW and ECW in children receiving dialysis.
Collapse
Affiliation(s)
- Gregorio P Milani
- Department of Pediatrics, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
| | - Jaap W Groothoff
- Pediatric Nephrology, Emma Children's Hospital/Academic Medical Center, Amsterdam, the Netherlands
| | - Federica A Vianello
- Department of Pediatrics, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Emilio F Fossali
- Department of Pediatrics, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Fabio Paglialonga
- Department of Pediatric Nephrology, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Alberto Edefonti
- Department of Pediatric Nephrology, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Carlo Agostoni
- Department of Pediatrics, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy; Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy
| | - Dario Consonni
- Epidemiology Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Dewi van Harskamp
- Pediatrics, Emma Children's Hospital/Academic Medical Center, Amsterdam, the Netherlands
| | - Johannes B van Goudoever
- Pediatrics, Emma Children's Hospital/Academic Medical Center, Amsterdam, the Netherlands; Pediatrics VU University Medical Center, Amsterdam, the Netherlands
| | - Henk Schierbeek
- Pediatrics, Emma Children's Hospital/Academic Medical Center, Amsterdam, the Netherlands
| | - Michiel J S Oosterveld
- Pediatric Nephrology, Emma Children's Hospital/Academic Medical Center, Amsterdam, the Netherlands
| |
Collapse
|
6
|
Guidotti S, Verstappen-Dumoulin BMAAA, Jansen HG, Aerts-Bijma AT, van Vliet AA, Scheurink AJW, Meijer HAJ, van Dijk G. Total energy expenditure assessed by salivary doubly labelled water analysis and its relevance for short-term energy balance in humans. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2016; 30:143-150. [PMID: 26661981 DOI: 10.1002/rcm.7412] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2015] [Revised: 09/07/2015] [Accepted: 09/28/2015] [Indexed: 06/05/2023]
Abstract
RATIONALE The doubly labelled water (DLW) method is a stable isotopic technique for measuring total energy expenditure (TEE). Saliva is the easiest sampling fluid for assessing isotopic enrichments, but blood is considered superior because of its rapid exchange with body water. Therefore, we compared a large range of isotopic enrichments in saliva and blood, and related TEE in subjects with their ad libitum total energy intake (TEI). The relevance of these parameters to body weight and fat change over an 8-day interval was also assessed. METHODS Thirty subjects underwent DLW analysis over either 8 or 14 days, during which time initial and final blood and saliva enrichments were compared. TEI was assessed by dieticians over the 8-day period only. Isotope ratio mass spectrometry was used for the measurement of δ(2)H and δ(18)O values. RESULTS No discrepancies were observed between sampling fluids over a wide range of enrichments. During the 8-day period, average TEI exceeded TEE by ~5% or less. Using saliva as sampling fluid, TEI and TEI-TEE, but not TEE, were positively correlated to body weight change. TEI-TEE and physical activity EE (AEE), but not TEI, correlated, respectively, positively and negatively to changes in fat mass. CONCLUSIONS The DLW method in humans can be reliably applied using saliva as sampling fluid. TEI-TEE as well as AEE contributes significantly to changes in fat mass over an 8-day period.
Collapse
Affiliation(s)
- Stefano Guidotti
- Center for Isotope Research (CIO), Energy and Sustainability Research Institute Groningen (ERSIG), University of Groningen, Nijenborgh 4, 9747, AG, Groningen, The Netherlands
- Groningen Institute for Evolutionary Life Sciences (GELIFES), Unit Behavioral Neuroscience, University of Groningen, Nijenborgh 7, 9747, AG, Groningen, The Netherlands
| | - Berthe M A A A Verstappen-Dumoulin
- Center for Isotope Research (CIO), Energy and Sustainability Research Institute Groningen (ERSIG), University of Groningen, Nijenborgh 4, 9747, AG, Groningen, The Netherlands
| | - Henk G Jansen
- Center for Isotope Research (CIO), Energy and Sustainability Research Institute Groningen (ERSIG), University of Groningen, Nijenborgh 4, 9747, AG, Groningen, The Netherlands
| | - Anita T Aerts-Bijma
- Center for Isotope Research (CIO), Energy and Sustainability Research Institute Groningen (ERSIG), University of Groningen, Nijenborgh 4, 9747, AG, Groningen, The Netherlands
| | - André A van Vliet
- PRA International, Stationsweg 163, 9471, GP, Zuidlaren, The Netherlands
| | - Anton J W Scheurink
- Groningen Institute for Evolutionary Life Sciences (GELIFES), Unit Behavioral Neuroscience, University of Groningen, Nijenborgh 7, 9747, AG, Groningen, The Netherlands
| | - Harro A J Meijer
- Center for Isotope Research (CIO), Energy and Sustainability Research Institute Groningen (ERSIG), University of Groningen, Nijenborgh 4, 9747, AG, Groningen, The Netherlands
| | - Gertjan van Dijk
- Center for Isotope Research (CIO), Energy and Sustainability Research Institute Groningen (ERSIG), University of Groningen, Nijenborgh 4, 9747, AG, Groningen, The Netherlands
- Groningen Institute for Evolutionary Life Sciences (GELIFES), Unit Behavioral Neuroscience, University of Groningen, Nijenborgh 7, 9747, AG, Groningen, The Netherlands
| |
Collapse
|
7
|
The Evaluation and Quantitation of Dihydrogen Metabolism Using Deuterium Isotope in Rats. PLoS One 2015; 10:e0130687. [PMID: 26103048 PMCID: PMC4477931 DOI: 10.1371/journal.pone.0130687] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Accepted: 05/24/2015] [Indexed: 11/19/2022] Open
Abstract
Purpose Despite the significant interest in molecular hydrogen as an antioxidant in the last eight years, its quantitative metabolic parameters in vivo are still lacking, as is an appropriate method for determination of hydrogen effectivity in the mammalian organism under various conditions. Basic Procedures Intraperitoneally-applied deuterium gas was used as a metabolic tracer and deuterium enrichment was determined in the body water pool. Also, in vitro experiments were performed using bovine heart submitochondrial particles to evaluate superoxide formation in Complex I of the respiratory chain. Main Findings A significant oxidation of about 10% of the applied dose was found under physiological conditions in rats, proving its antioxidant properties. Hypoxia or endotoxin application did not exert any effect, whilst pure oxygen inhalation reduced deuterium oxidation. During in vitro experiments, a significant reduction of superoxide formation by Complex I of the respiratory chain was found under the influence of hydrogen. The possible molecular mechanisms of the beneficial effects of hydrogen are discussed, with an emphasis on the role of iron sulphur clusters in reactive oxygen species generation and on iron species-dihydrogen interaction. Principal Conclusions According to our findings, hydrogen may be an efficient, non-toxic, highly bioavailable and low-cost antioxidant supplement for patients with pathological conditions involving ROS-induced oxidative stress.
Collapse
|
8
|
Scantlebury DM, Mills MGL, Wilson RP, Wilson JW, Mills MEJ, Durant SM, Bennett NC, Bradford P, Marks NJ, Speakman JR. Flexible energetics of cheetah hunting strategies provide resistance against kleptoparasitism. Science 2014; 346:79-81. [DOI: 10.1126/science.1256424] [Citation(s) in RCA: 73] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
Population viability is driven by individual survival, which in turn depends on individuals balancing energy budgets. As carnivores may function close to maximum sustained power outputs, decreased food availability or increased activity may render some populations energetically vulnerable. Prey theft may compromise energetic budgets of mesopredators, such as cheetahs and wild dogs, which are susceptible to competition from larger carnivores. We show that daily energy expenditure (DEE) of cheetahs was similar to size-based predictions and positively related to distance traveled. Theft at 25% only requires cheetahs to hunt for an extra 1.1 hour per day, increasing DEE by just 12%. Therefore, not all mesopredators are energetically constrained by direct competition. Other factors that increase DEE, such as those that increase travel, may be more important for population viability.
Collapse
|
9
|
Sijtsma A, Schierbeek H, Goris AHC, Joosten KFM, van Kessel I, Corpeleijn E, Sauer PJJ. Validation of the TracmorD triaxial accelerometer to assess physical activity in preschool children. Obesity (Silver Spring) 2013; 21:1877-83. [PMID: 23512533 DOI: 10.1002/oby.20401] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2012] [Accepted: 01/17/2013] [Indexed: 11/09/2022]
Abstract
OBJECTIVES To assess validity evidence of TracmorD to determine energy used for physical activity in 3-4-year-old children. DESIGN AND METHODS Participants were randomly selected from GECKO Drenthe cohort (n = 30, age 3.4 ± 0.3 years). Total energy expenditure (TEE) was measured using the doubly labeled water method. Sleeping metabolic rate (SMR) was measured by indirect calorimetry (Deltatrac). TEE and SMR were used to calculate physical activity level (PAL) and activity energy expenditure (AEE). Physical activity was monitored using a DirectLife triaxial accelerometer, TracmorD with activity counts per minute (ACM) and activity counts per day (ACD) as outcome measures. RESULTS The best predictor for PAL was ACM with gender and weight, the best predictor for AEE was ACM alone (backward regression, R(2) = 0.50, P = 0.010 and R2 = 0.31, P = 0.011, respectively). With ACD, the prediction model for PAL included ACD, height, gender, and sleep duration (R2 = 0.48, P = 0.033), the prediction model for AEE included ACD, gender and sleep duration (R2 = 0.39, P = 0.042). The accelerometer was worn for 5 days, but 3 days did not give a different estimated PAL. CONCLUSION TracmorD provides moderate-to-strong validity evidence that supports its use to evaluate energy used for physical activity in 3-4-year-old children.
Collapse
Affiliation(s)
- Anna Sijtsma
- Department of Epidemiology, University of Groningen, UMCG, Groningen, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
10
|
Schierbeek H, van den Akker CHP, Fay LB, van Goudoever JB. High-precision mass spectrometric analysis using stable isotopes in studies of children. MASS SPECTROMETRY REVIEWS 2012; 31:312-330. [PMID: 21769910 DOI: 10.1002/mas.20344] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2011] [Revised: 06/01/2011] [Accepted: 06/01/2011] [Indexed: 05/31/2023]
Abstract
The use of stable isotopes combined with mass spectrometry (MS) provides insight into metabolic processes within the body. Herein, an overview on the relevance of stable isotope methodology in pediatric research is presented. Applications for the use of stable isotopes with MS cover carbohydrate, fat, and amino acid metabolism as well as body composition, energy expenditure, and the synthesis of specific peptides and proteins, such as glutathione and albumin. The main focus of these studies is on the interactions between nutrients and the endogenous metabolism within the body and how these factors affect the health of a growing infant. Considering that the early imprinting of metabolic processes hugely impacts metabolism (and thus functional outcome) later in life, research in this area is important and is advancing rapidly. The major fluxes on a metabolic level are the synthesis and breakdown rates. They can be quantified using kinetic tracer analysis and mathematical modeling. Organic MS and isotope ratio mass spectrometry (IRMS) are the two most mature techniques for the isotopic analysis of compounds. Introduction of the samples is usually done by coupling gas chromatography (GC) to either IRMS or MS because it is the most robust technique for specific isotopic analysis of volatile compounds. In addition, liquid chromatography (LC) is now being used more often as a tool for sample introduction of both volatile and non-volatile compounds into IRMS or MS for (13)C isotopic analyses at natural abundances and for (13)C-labeled enriched compounds. The availability of samples is often limited in pediatric patients. Therefore, sample size restriction is important when developing new methods. Also, the availability of stable isotope-labeled substrates is necessary for measurements of the kinetics and concentrations in metabolic studies, which can be a limiting factor. During the last decade, the availability of these substrates has increased. Furthermore, improvements in the accuracy, precision, and sensitivity of existing techniques (such as GC/IRMS) and the development of new techniques (such as LC/IRMS) have opened up new avenues for tackling these limitations.
Collapse
Affiliation(s)
- Henk Schierbeek
- Division of Neonatology, Department of Pediatrics, Erasmus MC-Sophia Children's Hospital, P.O. Box 2060, 3000 CB Rotterdam, The Netherlands.
| | | | | | | |
Collapse
|
11
|
Sauvinet V, Gabert L, Alligier M, Normand S, Roth H, Laville M, Désage M. Comparison of high-temperature conversion and equilibration methods for the determination of d31-palmitic acid oxidation in man using continuous-flow isotope ratio mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2011; 25:2749-2759. [PMID: 21913252 DOI: 10.1002/rcm.5173] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
During nutritional interventions, the ingestion of d(31)-palmitic acid and H(2)(18)O allows the assessment of dietary fatty acid oxidation from cumulative (2)H recovery in urine and the estimation of the total body water pool (TBW) from (18)O dilution. Continuous-flow isotope ratio mass spectrometry (CF-IRMS) coupled to either equilibration or high-temperature conversion (HTC) techniques permits (2)H- and (18)O-enrichment measurements in biological fluids. Thus it was of great interest to compare these methods applied to the determination of dietary fatty acid oxidation. The linearity, accuracy and correlation between CF-equilibration and CF-HTC were first checked using (2)H- and (18)O-enriched water and urine samples. Urine samples from 14 subjects were then measured with both methods. The (2)H and (18)O raw data were normalised against calibration lines. The final aim was to study the impact of the normalised raw results on physiological data (i.e. TBW and d(31)-palmitate recovery). No significant difference was observed between the (18)O- and (2)H-enrichment measurements depending on the analytical method used. The TBW volumes calculated from the (18)O enrichments measured either with CF-equilibration or CF-HTC were not significantly different: respectively, 45.1 ± 1.0 L or 45.7 ± 1.0 L (mean ± sem, p = 0.09). The palmitic acid oxidation results obtained from the (2)H-enrichment measurements and the TBW from CF-equilibration vs. CF-HTC were not significantly different (p ≥ 0.26): with δ(2)H values of, respectively, 16.2 ± 1.6% vs. 16.2 ± 1.1% at 8 h, 18.7 ± 2.0% vs. 17.6 ± 1.3% at 12 h and 21.7 ± 1.9% vs. 21.5 ± 1.3% at 3 days post-dose (mean ± sem). Thus, even if CF-HTC was preferred because it was more practical to carry out, both methods allow the study of dietary lipid oxidation in man and generate similar results.
Collapse
Affiliation(s)
- Valérie Sauvinet
- Lyon University, CRNH Rhône-Alpes and Center for European Nutrition, Safety and Health, F-69310 Pierre Bénite, France.
| | | | | | | | | | | | | |
Collapse
|
12
|
Measuring energy expenditure and body composition in children with neurological impairment and intellectual disability using the doubly labeled water method: Comparing urine and saliva sampling. ACTA ACUST UNITED AC 2010. [DOI: 10.1016/j.eclnm.2010.07.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|